Utility of the Photoplethysmogram in Circulatory Monitoring
Open accessThe DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Abstract
The photoplethysmogram is a noninvasive circulatory signal related to the pulsatile volume of blood in tissue and is displayed by many pulse oximeters and bedside monitors, along with the computed arterial oxygen saturation. The photoplethysmogram is similar in appearance to an arterial blood pressure waveform. Because the former is noninvasive and nearly ubiquitous in hospitals whereas the latter requires invasive measurement, the extraction of circulatory information from the photoplethysmogram has been a popular subject of contemporary research. The photoplethysmogram is a function of the underlying circulation, but the relation is complicated by optical, biomechanical, and physiologic covariates that affect the appearance of the photoplethysmogram. Overall, the photoplethysmogram provides a wealth of circulatory information, but its complex etiology may be a limitation in some novel applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The measurement of volume changes in human limbs
Whitney, R. J. (1953) · The Journal of Physiology · doi:10.1113/jphysiol.1953.sp004926 · Cited by 1,489
A Monte Carlo model for the absorption and flux distributions of light in tissue
Wilson, B. C., & Adam, G. (1983) · Medical Physics · doi:10.1118/1.595361 · Cited by 690
Clinical applications of arterial stiffness, Task Force III: recommendations for user procedures
Van Bortel, L. M., Duprez, D., Starmans-Kool, M. J., Safar, M. E., Giannattasio, C., Cockcroft, J., Kaiser, D. R., & Thuillez, C. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02326-3 · Cited by 630
Langewouters, G. J., Wesseling, K. H., & Goedhard, W. J. A. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90034-4 · Cited by 544
Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure
Payne, R. A., Symeonides, C. N., Webb, D. J., & Maxwell, S. R. J. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00657.2005 · Cited by 418 · cited 1×
“Options for the proximal signal include the sound of the mitral valve, a proximal photoplethysmogram or ABP signal, or an electrocardiogram, although the electrocardiogram is not a reliable indicator of mechanical systole.(81) Such issues have been reviewed, with recommendations available for PTT/ pulse wave velocity…”
Skin photoplethysmography — a review
Kamal, A. A. R., Harness, J. B., Irving, G., & Mearns, A. J. (1989) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(89)90159-4 · Cited by 328
Noninvasive Assessment of the Digital Volume Pulse: Comparison With the Peripheral Pressure Pulse
Millasseau, S. C., Guigui, F. G., Kelly, R. P., Prasad, K., Cockcroft, J. R., Ritter, J. M., & Chowienczyk, P. J. (2000) · Hypertension · doi:10.1161/01.hyp.36.6.952 · Cited by 294
Pulse wave analysis and pulse wave velocity: a critical review of their strengths and weaknesses
Davies, J. I., & Struthers, A. D. (2003) · Journal of Hypertension · doi:10.1097/00004872-200303000-00004 · Cited by 289
Tardy, Y., Meister, J. J., Perret, F., Brunner, H. R., & Arditi, M. (1991) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/12/1/003 · Cited by 270
Theoretical Analysis of Diffuse Reflectance from a Two-Layer Tissue Model
Takatani, S., & Graham, M. D. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326455 · Cited by 249
Cited by
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
“Several reviews have been written on PPG in the past decade [64], [66]–[68].”
BackgroundInfluentialPhotoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 422
A new look at the essence of the imaging photoplethysmography
Kamshilin, A. A., Nippolainen, E., Sidorov, I. S., Vasilev, P. V., Erofeev, N. P., Podolian, N. P., & Romashko, R. V. (2015) · Scientific Reports · doi:10.1038/srep10494 · Cited by 248
Current progress of photoplethysmography and SPO2 for health monitoring
Tamura, T. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-019-00097-w · Cited by 247
Krittanawong, C., Rogers, A. J., Johnson, K. W., Wang, Z., Turakhia, M. P., Halperin, J. L., & Narayan, S. M. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-00445-9 · Cited by 234
Photoplethysmographic derivation of respiratory rate: A review of relevant physiology
Meredith, D. J., Clifton, D., Charlton, P., Brooks, J., Pugh, C. W., & Tarassenko, L. (2012) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2011.638965 · Cited by 226
Human Vital Signs Detection Methods and Potential Using Radars: A Review
Kebe, M., Gadhafi, R., Mohammad, B., Sanduleanu, M., Saleh, H., & Al-Qutayri, M. (2020) · Sensors · doi:10.3390/s20051454 · Cited by 205
“Human breath rate can be measured using characteristics of the inhaled and exhaled air such as its carbon dioxide (CO 2 ), its humidity and temperature. signs detection using breath air-sensing methods.”
Diagnostic Features and Potential Applications of PPG Signal in Healthcare: A Systematic Review
Almarshad, M. A., Islam, M. S., Al-Ahmadi, S., & BaHammam, A. S. (2022) · Healthcare · doi:10.3390/healthcare10030547 · Cited by 188
“Some of them focus on the specific medical use of PPG like pulse rate [3], blood pressure [4,5], atrial fibrillation [6,7], circulatory monitoring [8], nociception [9], or on the specific placement of PPG [10,11], others instead focused on reviewing the way that the signal has been analyzed [7,12–16] or the type of th…”
BackgroundNoncontact Monitoring Breathing Pattern, Exhalation Flow Rate and Pulse Transit Time
Shao, D., Yang, Y., Liu, C., Tsow, F., Yu, H., & Tao, N. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2327024 · Cited by 183
“Despite the attractive features of imaging-based noncontact approach, the signals extracted from the images contain noise from various sources [18].”
BackgroundCuffless Blood Pressure Measurement
Mukkamala, R., Stergiou, G. S., & Avolio, A. P. (2022) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110220-014644 · Cited by 180
Camera Measurement of Physiological Vital Signs
McDuff, D. (2023) · ACM Computing Surveys · doi:10.1145/3558518 · Cited by 159
Assessment of the Fitbit Charge 2 for monitoring heart rate
Benedetto, S., Caldato, C., Bazzan, E., Greenwood, D. C., Pensabene, V., & Actis, P. (2018) · PLOS ONE · doi:10.1371/journal.pone.0192691 · Cited by 149
The analysis of PPG morphology: Investigating the effects of aging on arterial compliance
Yousef, Q., Reaz, M. B. I., & Ali, M. A. M. (2012) · Measurement Science Review · doi:10.2478/v10048-012-0036-3 · Cited by 126
Multi-wavelength photoplethysmography method for skin arterial pulse extraction
Liu, J., Yan, B. P.-Y., Dai, W.-X., Ding, X.-R., Zhang, Y.-T., & Zhao, N. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.004313 · Cited by 107
Chatterjee, S., & Kyriacou, P. A. (2019) · Sensors · doi:10.3390/s19040789 · Cited by 86
Qawqzeh, Y. K., Bajahzar, A. S., Jemmali, M., Otoom, M. M., & Thaljaoui, A. (2020) · BioMed Research International · doi:10.1155/2020/3764653 · Cited by 71
RetractedHickey, M., Phillips, J. P., & Kyriacou, P. A. (2016) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-015-9761-0 · Cited by 49
Reducing motion artifacts in photoplethysmograms by using relative sensor motion: Phantom study
Wijshoff, R. W. C. G. R., Mischi, M., Veen, J., & Van Der Lee, A. M. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.11.117007 · Cited by 40
“This is opposite to most in vivo reflectance PPGs, which show a decrease upon an increase in blood volume, as a result of increased absorption.(10,46) In case 3, a PPG is measured of which the amplitude is in antiphase with window deflection [Fig.”
Couceiro, R., Carvalho, P., Paiva, R. P., Henriques, J., & Muehlsteff, J. (2012) · 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2012.6346497 · Cited by 33
Pulse Oximetry at the Wrist During Sleep: Performance, Challenges and Perspectives
Braun, F., Theurillat, P., Proenca, M., Lemkaddem, A., Ferrario, D., De Jaegere, K., Horvath, C. M., Roth, C., Brill, A.-K., Lemay, M., et al. (2020) · 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176081 · Cited by 21
Feng, Y., Drzymalski, D., Zhao, B., Wang, X., & Chen, X. (2018) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-018-1914-y · Cited by 9
Metadata
- Authors
- Reisner, A., Shaltis, P. A., McCombie, D., Asada, H. H., Warner, D. S., & Warner, M. A.
- Venue
- Anesthesiology
- Published
- 2008-05-01
- Volume
- 108
- Issue
- 5
- Pages
- 950-958
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2072858761
- Cited by
- 366
- References
- 65
- FWCI
- 7.89
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.