Utility of the Photoplethysmogram in Circulatory Monitoring
Open accessThe DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Abstract
The photoplethysmogram is a noninvasive circulatory signal related to the pulsatile volume of blood in tissue and is displayed by many pulse oximeters and bedside monitors, along with the computed arterial oxygen saturation. The photoplethysmogram is similar in appearance to an arterial blood pressure waveform. Because the former is noninvasive and nearly ubiquitous in hospitals whereas the latter requires invasive measurement, the extraction of circulatory information from the photoplethysmogram has been a popular subject of contemporary research. The photoplethysmogram is a function of the underlying circulation, but the relation is complicated by optical, biomechanical, and physiologic covariates that affect the appearance of the photoplethysmogram. Overall, the photoplethysmogram provides a wealth of circulatory information, but its complex etiology may be a limitation in some novel applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The measurement of volume changes in human limbs
Whitney, R. J. (1953) · The Journal of Physiology · doi:10.1113/jphysiol.1953.sp004926 · Cited by 1,489
A Monte Carlo model for the absorption and flux distributions of light in tissue
Wilson, B. C., & Adam, G. (1983) · Medical Physics · doi:10.1118/1.595361 · Cited by 690
Clinical applications of arterial stiffness, Task Force III: recommendations for user procedures
Van Bortel, L. M., Duprez, D., Starmans-Kool, M. J., Safar, M. E., Giannattasio, C., Cockcroft, J., Kaiser, D. R., & Thuillez, C. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02326-3 · Cited by 630
Langewouters, G. J., Wesseling, K. H., & Goedhard, W. J. A. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90034-4 · Cited by 544
Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure
Payne, R. A., Symeonides, C. N., Webb, D. J., & Maxwell, S. R. J. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00657.2005 · Cited by 418 · cited 1×
“Options for the proximal signal include the sound of the mitral valve, a proximal photoplethysmogram or ABP signal, or an electrocardiogram, although the electrocardiogram is not a reliable indicator of mechanical systole.(81) Such issues have been reviewed, with recommendations available for PTT/ pulse wave velocity…”
Skin photoplethysmography — a review
Kamal, A. A. R., Harness, J. B., Irving, G., & Mearns, A. J. (1989) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(89)90159-4 · Cited by 328
Noninvasive Assessment of the Digital Volume Pulse: Comparison With the Peripheral Pressure Pulse
Millasseau, S. C., Guigui, F. G., Kelly, R. P., Prasad, K., Cockcroft, J. R., Ritter, J. M., & Chowienczyk, P. J. (2000) · Hypertension · doi:10.1161/01.hyp.36.6.952 · Cited by 294
Pulse wave analysis and pulse wave velocity: a critical review of their strengths and weaknesses
Davies, J. I., & Struthers, A. D. (2003) · Journal of Hypertension · doi:10.1097/00004872-200303000-00004 · Cited by 289
Tardy, Y., Meister, J. J., Perret, F., Brunner, H. R., & Arditi, M. (1991) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/12/1/003 · Cited by 270
Theoretical Analysis of Diffuse Reflectance from a Two-Layer Tissue Model
Takatani, S., & Graham, M. D. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326455 · Cited by 249
Finometer, finger pressure measurements with the possibility to reconstruct brachial pressure
Guelen, I., Westerhof, B. E., van der Sar, G. L., van Montfrans, G. A., Kiemeneij, F., Wesseling, K. H., & Bos, W. J. W. (2003) · Blood Pressure Monitoring · doi:10.1097/00126097-200302000-00006 · Cited by 219
Nitzan, M., Babchenko, A., Khanokh, B., & Landau, D. (1998) · Physiological Measurement · doi:10.1088/0967-3334/19/1/008 · Cited by 217
Pulse oximetry plethysmographic waveform during changes in blood volume
Shamir, M., Eidelman, L. A., Floman, Y., Kaplan, L., & Pizov, R. (1999) · British Journal of Anaesthesia · doi:10.1093/bja/82.2.178 · Cited by 184
Optical diffusion in layered media
Keijzer, M., Star, W. M., & Storchi, P. R. M. (1988) · Applied Optics · doi:10.1364/ao.27.001820 · Cited by 183
The effect of contacting force on photoplethysmographic signals
Teng, X. F., & Zhang, Y. T. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/5/020 · Cited by 171 · cited 1×
“plitude and shape) when the pressure applied by a probe is altered.(43) This is intuitive when one considers the”
BackgroundValidation of a device to measure arterial pulse wave velocity by a photoplethysmographic method
Loukogeorgakis, S., Dawson, R., Phillips, N., Martyn, C. N., & Greenwald, S. E. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/3/309 · Cited by 164
Elastic Environment of the Capillary Bed
Fung, Y. C., Zweifach, B. W., & Intaglietta, M. (1966) · Circulation Research · doi:10.1161/01.res.19.2.441 · Cited by 156
Pulse Oximeter Failure Thresholds in Hypotension and Vasoconstriction
Severinghaus, J. W., & Spellman, M. J. (1990) · Anesthesiology · doi:10.1097/00000542-199009000-00025 · Cited by 140
Hashimoto, J., Chonan, K., Aoki, Y., Nishimura, T., Ohkubo, T., Hozawa, A., Suzuki, M., Matsubara, M., Michimata, M., Araki, T., et al. (2002) · Journal of Hypertension · doi:10.1097/00004872-200212000-00021 · Cited by 124
Johansson, A., & Öberg, P. Å. (1999) · Medical & Biological Engineering & Computing · doi:10.1007/bf02513264 · Cited by 119
A Consensus View on the Technique of Ambulatory Blood Pressure Monitoring
Staessen, J. A., Fagard, R., Thijs, L., & Amery, A. (1995) · Hypertension · doi:10.1161/01.hyp.26.6.912 · Cited by 119
Simple photon diffusion analysis of the effects of multiple scattering on pulse oximetry
Schmitt, J. M. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.137285 · Cited by 118
Photoelectric plethysmography-some fundamental aspects of the reflection and transmission methods
Nijboer, J. A., Dorlas, J. C., & Mahieu, H. F. (1981) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/2/3/004 · Cited by 116
The vascular impact of aging andvasoactive drugs: comparison of twodigital volume pulse measurements
Millasseau, S., Kelly, R. P., Ritter, J. M., & Chowienczyk, P. J. (2003) · American Journal of Hypertension · doi:10.1016/s0895-7061(03)00569-7 · Cited by 113
Vasomotion patterns in skeletal muscle arterioles during changes in arterial pressure
Meyer, J.-U., Borgström, P., Lindbom, L., & Intaglietta, M. (1988) · Microvascular Research · doi:10.1016/0026-2862(88)90062-3 · Cited by 105
Shelley, K. H., Tamai, D., Jablonka, D., Gesquiere, M., Stout, R. G., & Silverman, D. G. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000145063.01043.4b · Cited by 91 · cited 1×
“Note that reflectance-mode probes are often adhered to the patient and may not apply enough pressure to collapse the low-pressure venous system, so venous oscillations can be more significant than in transmissionmode photoplethysmography.(27,28) Oscillations in lowpressure vasculature are, in part, due to respiratory…”
MethodPressure-diameter relationships of segments of human finger arteries
Langewouters, G. J., Zwart, A., Busse, R., & Wesseling, K. H. (1986) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/7/1/003 · Cited by 91
Optimal probe geometry for near-infrared spectroscopy of biological tissue
Kumar, G., & Schmitt, J. M. (1997) · Applied Optics · doi:10.1364/ao.36.002286 · Cited by 90
Kim, J.-M., Arakawa, K., Benson, K. T., & Fox, D. K. (1986) · Anesthesia & Analgesia · doi:10.1213/00000539-198612000-00015 · Cited by 86
Allen, J., & Murray, A. (1999) · Physiological Measurement · doi:10.1088/0967-3334/20/3/306 · Cited by 71
Babchenko, A., Davidson, E. M., Ginosar, Y., Kurz, V., Faib, I., Adler, D., & Nitzan, M. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/2/310 · Cited by 67
Arterial-pulse oximetry loops: a new method of monitoring vascular tone.
Shelley, K. H., Murray, W. B., & Chang, D. (1997) · The Journal of Clinical Monitoring · doi:10.1023/a:1007361020825 · Cited by 61
Reflection photoplethysmography of arterial-blood-volume pulses
Weinman, J., Hayat, A., & Raviv, G. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441571 · Cited by 57
The pulse in reflectance pulse oximetry: Modeling and experimental studies
Reuss, J. L., & Siker, D. (2004) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-005-2909-6 · Cited by 56
Verylow frequency variability in arterial blood pressure and blood volume pulse
Nitzan, M., Babchenko, A., & Khanokh, B. (1999) · Medical & Biological Engineering & Computing · doi:10.1007/bf02513266 · Cited by 56
Nilsson, L., Johansson, A., & Kalman, S. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/4/009 · Cited by 55 · cited 1×
“Oscillations in lowpressure vasculature are, in part, due to respiratory effort, so reflectance mode has been used to extract respiratory rate and volume data from the photoplethysmogram.(29,30) A finger probe, i.”
MethodNitzan, M., Faib, I., & Friedman, H. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2236285 · Cited by 55
Effects of filtering on multi-site photoplethysmography pulse waveform characteristics
Allen, J., & Murray, A. (2005) · Computers in Cardiology, 2004 · doi:10.1109/cic.2004.1442980 · Cited by 54
Observations on blood flow related electrical impedance changes in rigid tubes
Visser, K. R., Lamberts, R. P., Korsten, H. H. M., & Zijlstra, W. G. (1976) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00585894 · Cited by 53
Feng, W., Haishu, D., Fenghua, T., Jun, Z., Qing, X., & Xianwu, T. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/1/323 · Cited by 53
Accuracy of pulse oximetry in patients with low systemic vascular resistance
Secker, C., & Spiers, P. (1997) · Anaesthesia · doi:10.1111/j.1365-2044.1997.32-az0062.x · Cited by 51
Awad, A. A., Ghobashy, M. A. M., Stout, R. G., Silverman, D. G., & Shelley, K. H. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200112000-00022 · Cited by 50
Opacity pulse of individual minute arteries.
D’Agrosa, L. S., & Hertzman, A. B. (1967) · Journal of Applied Physiology · doi:10.1152/jappl.1967.23.5.613 · Cited by 49
The Relationship between Pulse Volume and Blood Flow in the Finger
Zweifler, A. J., Cushing, G., & Conway, J. (1967) · Angiology · doi:10.1177/000331976701801001 · Cited by 48
The finger volume pulse and assessment of arterial properties
Avolio, A. P. (2002) · Journal of Hypertension · doi:10.1097/00004872-200212000-00007 · Cited by 47
Talke, P. O., Nichols, R. J., & Traber, D. L. (1990) · Journal of Clinical Monitoring and Computing · doi:10.1007/bf02832176 · Cited by 46
Sympathetically induced spontaneous fluctuations of the photoplethysmographic signal
Khanoka, B., Slovik, Y., Landau, D., & Nitzan, M. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02351014 · Cited by 45
Maestri, R., Pinna, G. D., Robbi, E., Capomolla, S., & Rovere, M. T. L. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/6/021 · Cited by 45
Changes in finger-aorta pressure transfer function during and after exercise
Stok, W. J., Westerhof, B. E., & Karemaker, J. M. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00876.2005 · Cited by 45
Ugnell, H., & Öberg, P. Å. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)00008-b · Cited by 39
Almond, N. E., Jones, D. P., & Cooke, E. D. (1988) · Angiology · doi:10.1177/000331978803900906 · Cited by 38
Ando, J., KAWARADA, A., Shibata, M., Yamakoshi, K.-I., & Kamiya, A. (1991) · Japanese Circulation Journal-english Edition · doi:10.1253/jcj.55.567 · Cited by 37
Evaluation of pulse oximetry during cardiopulmonary resuscitation
SPITTAL, M. J. (1993) · Anaesthesia · doi:10.1111/j.1365-2044.1993.tb07185.x · Cited by 36
pnar, A. E.-T., Uiterkamp, L. A., Sikkema, J. M., Bots, M. L., Koomans, H. A., Bruinse, H. W., & Franx, A. (2003) · Journal of Hypertension · doi:10.1097/00004872-200311000-00014 · Cited by 36
Measurement of systolic blood pressure using pulse oximetry during helicopter flight
Talke, P. O. (1991) · Critical Care Medicine · doi:10.1097/00003246-199107000-00018 · Cited by 35
Arterial Haemodynamics and Ventricular-Vascular Interaction in Hypertension
O’Rourke, M. F. (1994) · Blood Pressure · doi:10.3109/08037059409101519 · Cited by 35
Forearm arterial compliance: a new measure of arterial compliance?
Dh, F. (1984) · Cardiovascular Research · doi:10.1093/cvr/18.11.651 · Cited by 30
A method for clinical evaluation of peripheral circulation: photoelectric hemodensitometry.
ELDRUP-JORGENSEN, S., Schwartz, S. I., & Jd, W. (1966) · PubMed · Cited by 28
The effect of pulsating arteries on reflectance pulse oximetry: Measurements in adults and neonates
Nijland, R., Jongsma, W., van den Berg, P. P., Nijhuis, J. G., & Oeseburg, B. (1995) · The Journal of Clinical Monitoring · doi:10.1007/bf01617733 · Cited by 24
Skin Vasomotor Reflex as a Measure of Depth of Anesthesia
Ezri, T., Steinmetz, A., Geva, D., & Szmuk, P. (1998) · Anesthesiology · doi:10.1097/00000542-199811000-00041 · Cited by 20
Use of pulse oximetry for blood pressure measurement after cardiac surgery
Movius, A. J., Bratton, S. L., & Sorensen, G. K. (1998) · Archives of Disease in Childhood · doi:10.1136/adc.78.5.457 · Cited by 16
The Peripheral Pulse Monitor — A Review of Electrical Plethysmography
Sara, C. A., & Shanks, C. A. (1978) · Anaesthesia and Intensive Care · doi:10.1177/0310057x7800600309 · Cited by 14
Buclin, T., Buchwalder‐Csajka, Brunner, & Biollaz (1999) · British Journal of Clinical Pharmacology · doi:10.1046/j.1365-2125.1999.00049.x · Cited by 11
Nijland, R., Jongsma, H. W., Verbruggen, I. M., & Nijhuis, J. G. (1996) · Journal of Clinical Monitoring · doi:10.1007/bf00857643 · Cited by 8
Undisrupted pulse wave on pulse oximeter display monitor at cardiac arrest in a surgical patient
Kuroda, M., Kawamoto, M., & Yuge, O. (2005) · Journal of Anesthesia · doi:10.1007/s00540-004-0298-5 · Cited by 5
Cited by
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
“Several reviews have been written on PPG in the past decade [64], [66]–[68].”
BackgroundInfluentialPhotoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 422
A new look at the essence of the imaging photoplethysmography
Kamshilin, A. A., Nippolainen, E., Sidorov, I. S., Vasilev, P. V., Erofeev, N. P., Podolian, N. P., & Romashko, R. V. (2015) · Scientific Reports · doi:10.1038/srep10494 · Cited by 248
Current progress of photoplethysmography and SPO2 for health monitoring
Tamura, T. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-019-00097-w · Cited by 247
Metadata
- Authors
- Reisner, A., Shaltis, P. A., McCombie, D., Asada, H. H., Warner, D. S., & Warner, M. A.
- Venue
- Anesthesiology
- Published
- 2008-05-01
- Volume
- 108
- Issue
- 5
- Pages
- 950-958
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2072858761
- Cited by
- 366
- References
- 65
- FWCI
- 7.89
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.