The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Practice Guidelines for Management of the Difficult Airway: An Updated Report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway
Abstract
P RACTICE Guidelines are systematically developed recommendations that assist the practitioner and patient in making decisions about health care.These recommendations may be adopted, modified, or rejected according to clinical needs and constraints and are not intended to replace local institutional policies.In addition, Practice Guidelines developed by the American Society of Anesthesiologists (ASA) are not intended as standards or absolute requirements, and their use cannot guarantee any specific outcome.Practice Guidelines are subject to revision as warranted by the evolution of medical knowledge, technology, and practice.They provide basic recommendations that are supported by a synthesis and analysis of the current literature, expert and practitioner opinion, open-forum commentary, and clinical feasibility data.This document updates the "Practice Guidelines for Management of the Difficult Airway: An Updated Report by the Task Force on Difficult Airway Management," adopted by the ASA in 2002 and published in 2003.* Methodology A. Definition of Difficult AirwayA standard definition of the difficult airway cannot be identified in the available literature.For these Practice Guidelines, a difficult airway is defined as the clinical situation in which a conventionally trained anesthesiologist experiences difficulty with facemask ventilation of the upper airway, difficulty with tracheal intubation, or both.The difficult airway represents a complex interaction between patient factors, the clinical setting, and the skills of the practitioner.Analysis of this interaction requires precise collection and communication of data.The Task Force urges clinicians and investigators to use explicit descriptions of the difficult airway.Descriptions that can be categorized or expressed as numerical values are particularly desirable, because this type of information lends itself to aggregate analysis and cross-study comparisons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prediction of Difficult Mask Ventilation
Langeron, O., Masso, E., Huraux, C., Guggiari, M., Bianchi, A., Coriat, P., & Riou, B. (2000) · Anesthesiology · doi:10.1097/00000542-200005000-00009 · Cited by 915
PREDICTING DIFFICULT INTUBATION
WILSON, M. E., SPIEGELHALTER, D., ROBERTSON, J. A., & LESSER, P. (1988) · British Journal of Anaesthesia · doi:10.1093/bja/61.2.211 · Cited by 875
The airway: problems and predictions in 18,500 patients
Rose, D. K., & Cohen, M. M. (1994) · Canadian Journal of Anaesthesia · doi:10.1007/bf03009858 · Cited by 645
Relative Risk Analysis of Factors Associated with Difficult Intubation in Obstetric Anesthesia
Rocke, D. A., Murray, W. B., Rout, C. C., & Gouws, E. (1992) · Anesthesiology · doi:10.1097/00000542-199207000-00010 · Cited by 402
Aziz, M. F., Healy, D., Kheterpal, S., Fu, R. F., Dillman, D., & Brambrink, A. M. (2011) · Anesthesiology · doi:10.1097/aln.0b013e3182023eb7 · Cited by 395
Airway Injury during Anesthesia: A Closed Claims Analysis
Domino, K. B., Posner, K. L., Caplan, R. A., & Cheney, F. W. (1999) · Anesthesiology · doi:10.1097/00000542-199912000-00023 · Cited by 357
Self-citationAziz, M. F., Dillman, D., Fu, R., & Brambrink, A. M. (2012) · Anesthesiology · doi:10.1097/aln.0b013e318246ea34 · Cited by 352
Incidence and predictors of difficult laryngoscopy in 11.219 pediatric anesthesia procedures
Heinrich, S., Birkholz, T., Ihmsen, H., Irouschek, A., Ackermann, A., & Schmidt, J. (2012) · Pediatric Anesthesia · doi:10.1111/j.1460-9592.2012.03813.x · Cited by 266
Complications associated with the use of the GlideScope® videolaryngoscope
Cooper, R. M. (2007) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/bf03021900 · Cited by 238
Analysis of demographic characteristics.
Jorm, C., & Strunin, L. (1994) · PubMed · Cited by 234
Cited by
Frerk, C., Mitchell, V. S., McNarry, A. F., Mendonca, C., Bhagrath, R., Patel, A., O’Sullivan, E. P., Woodall, N. M., & Ahmad, I. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev371 · Cited by 2,214
Apfelbaum, J. L., Hagberg, C. A., Connis, R. T., Abdelmalak, B. B., Agarkar, M., Dutton, R. P., Fiadjoe, J. E., Greif, R., Klock, P. A., Mercier, D., et al. (2022) · Anesthesiology · doi:10.1097/aln.0000000000004002 · Cited by 1,340
Self-citationGuidelines for the management of tracheal intubation in critically ill adults
Higgs, A., McGrath, B. A., Goddard, C., Rangasami, J., Suntharalingam, G., Gale, R., & Cook, T. M. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2017.10.021 · Cited by 900
Nates, J. L., Nunnally, M., Kleinpell, R., Blosser, S., Goldner, J., Birriel, B., Fowler, C. S., Byrum, D., Miles, W. S., Bailey, H., et al. (2016) · Critical Care Medicine · doi:10.1097/ccm.0000000000001856 · Cited by 683
Mushambi, M. C., Kinsella, S. M., Popat, M., Swales, H., Ramaswamy, K. K., Winton, A. L., & Quinn, A. C. (2015) · Anaesthesia · doi:10.1111/anae.13260 · Cited by 608
Sakles, J. C., Chiu, S., Mosier, J., Walker, C., & Stolz, U. (2013) · Academic Emergency Medicine · doi:10.1111/acem.12055 · Cited by 565
Difficult Airway Society guidelines for awake tracheal intubation (ATI) in adults
Ahmad, I., El‐Boghdadly, K., Bhagrath, R., Hodzovic, I., McNarry, A. F., Mir, F., O'Sullivan, E. P., Patel, A., Stacey, M., & Vaughan, D. (2020) · Anaesthesia · doi:10.1111/anae.14904 · Cited by 563
Dort, J. C., Farwell, D. G., Findlay, M., Huber, G. F., Kerr, P., Shea-Budgell, M. A., Simon, C., Uppington, J., Zygun, D., Ljungqvist, O., et al. (2017) · JAMA Otolaryngology–Head & Neck Surgery · doi:10.1001/jamaoto.2016.2981 · Cited by 527
Apfelbaum, J. L., Hagberg, C. A., Connis, R. T., Abdelmalak, B., Agarkar, M., Dutton, R. P., Fiadjoe, J. E., Greif, R. T., Klock, P. A., Mercier, D. W., et al. (2022) · doi:10.48350/161339 · Cited by 526
Self-citationComplications and failure of airway management
Cook, T. M., & MacDougall-Davis, S. R. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes393 · Cited by 525
Clinical Practice Guideline: Improving Voice Outcomes after Thyroid Surgery
Chandrasekhar, S. S., Randolph, G. W., Seidman, M. D., Rosenfeld, R. M., Angelos, P., Barkmeier‐Kraemer, J., Benninger, M. S., Blumin, J. H., Dennis, G., Hanks, J., et al. (2013) · Otolaryngology–Head and Neck Surgery · doi:10.1177/0194599813487301 · Cited by 466
Fiadjoe, J. E., Nishisaki, A., Jagannathan, N., Hunyady, A. I., Greenberg, R. S., Reynolds, P. I., Matuszczak, M. E., Rehman, M. A., Polaner, D. M., Szmuk, P., et al. (2016) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(15)00508-1 · Cited by 463
Cardiac Arrest in Pregnancy: A Scientific Statement From the American Heart Association
Jeejeebhoy, F. M., Zelop, C. M., Lipman, S., Carvalho, B., Joglar, J., Mhyre, J. M., Katz, V. L., Lapinsky, S. E., Einav, S., Warnes, C. A., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000300 · Cited by 420
De Hert, S., Staender, S., Fritsch, G., Hinkelbein, J., Afshari, A., Bettelli, G., Bock, M., Chew, M. S., Coburn, M., De Robertis, E., et al. (2018) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000000817 · Cited by 389
for the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0019-3 · Cited by 358
International Consensus Statement on Obstructive Sleep Apnea
Chang, J. L., Goldberg, A. N., Alt, J. A., Mohammed, A., Ashbrook, L., Auckley, D., Ayappa, I., Bakhtiar, H., Barrera, J. E., Bartley, B. L., et al. (2023) · International Forum of Allergy & Rhinology · doi:10.1002/alr.23079 · Cited by 350
Nørskov, A. K., Rosenstock, C. V., Wetterslev, J., Astrup, G., Afshari, A., & Lundstrøm, L. H. (2015) · Anaesthesia · doi:10.1111/anae.12955 · Cited by 346
Kheterpal, S., Healy, D., Aziz, M. F., Shanks, A. M., Freundlich, R. E., Linton, F., Martin, L. D., Linton, J., Epps, J. L., Fernandez-Bustamante, A., et al. (2013) · Anesthesiology · doi:10.1097/aln.0000435832.39353.20 · Cited by 343
Difficult Airway Society guidelines for the management of tracheal extubation
Cooper, R. M., O'Sullivan, E., Popat, M., Behringer, E., & Hagberg, C. A. (2013) · Anaesthesia · doi:10.1111/anae.12139 · Cited by 336
Self-citationFailed tracheal intubation during obstetric general anaesthesia: a literature review
Kinsella, S. M., Winton, A. L., Mushambi, M. C., Ramaswamy, K., Swales, H., Quinn, A. C., & Popat, M. (2015) · International Journal of Obstetric Anesthesia · doi:10.1016/j.ijoa.2015.06.008 · Cited by 333
Hinkelbein, J., Lamperti, M., Akeson, J., Santos, J., Costa, J., De Robertis, E., Longrois, D., Novak-Jankovic, V., Petrini, F., Struys, M. M. R. F., et al. (2018) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000000683 · Cited by 313
Hasegawa, K., Shigemitsu, K., Hagiwara, Y., Chiba, T., Watase, H., Brown, C. A., & Brown, D. F. M. (2012) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2012.04.005 · Cited by 312
Myatra, S. N., Shah, A., Kundra, P., Patwa, A., Ramkumar, V., Divatia, J. V., Raveendra, U. S., Shetty, S. R., Ahmed, S. M., Doctor, J. R., et al. (2016) · Indian Journal of Anaesthesia · doi:10.4103/0019-5049.195481 · Cited by 294
Zuo, M., Huang, Y., Ma, W., Xue, Z., Zhang, J., Gong, Y., & Che, L. (2020) · cmsj · doi:10.24920/003724 · Cited by 294
The difficult airway with recommendations for management – Part 2 – The anticipated difficult airway
for the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0020-x · Cited by 276
Will This Patient Be Difficult to Intubate?: The Rational Clinical Examination Systematic Review
Detsky, M. E., Jivraj, N., Adhikari, N. K., Friedrich, J. O., Pinto, R., Simel, D. L., Wijeysundera, D. N., & Scales, D. C. (2019) · JAMA · doi:10.1001/jama.2018.21413 · Cited by 265
Vourc’h, M., Asfar, P., Volteau, C., Bachoumas, K., Clavieras, N., Egreteau, P.-Y., Asehnoune, K., Mercat, A., Reignier, J., Jaber, S., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3796-z · Cited by 260
Roth, D., Pace, N. L., Lee, A., Hovhannisyan, K., Warenits, A.-M., Arrich, J., & Herkner, H. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008874.pub2 · Cited by 257
Rosenstock, C. V., Thøgersen, B., Afshari, A., Christensen, A.-L., Eriksen, C., & Gätke, M. R. (2012) · Anesthesiology · doi:10.1097/aln.0b013e318254d085 · Cited by 255
Emergency cricothyrotomy—a systematic review
Langvad, S., Hyldmo, P. K., Nakstad, A. R., Vist, G. E., & Sandberg, M. (2013) · Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine · doi:10.1186/1757-7241-21-43 · Cited by 152
Transtracheal jet ventilation in the “can’t intubate can’t oxygenate” emergency: a systematic review
Duggan, L. V., Ballantyne Scott, B., Law, J. A., Morris, I. R., Murphy, M. F., & Griesdale, D. E. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew192 · Cited by 114
Nørskov, A. K., Wetterslev, J., Rosenstock, C. V., Afshari, A., Astrup, G., Jakobsen, J. C., Thomsen, J. L., Bøttger, M., Ellekvist, M., Schousboe, B. M. B., et al. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew057 · Cited by 78
Endotracheal intubation in the ICU
Lapinsky, S. E. (2015) · Critical Care · doi:10.1186/s13054-015-0964-z · Cited by 78
STOP-Bang and prediction of difficult airway in obese patients
Toshniwal, G., McKelvey, G. M., & Wang, H. (2014) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2014.01.010 · Cited by 64
Gu, Y., Robert, J., Kovacs, G., Milne, A. D., Morris, I., Hung, O., MacQuarrie, K., Mackinnon, S., & Adam Law, J. (2016) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-016-0654-6 · Cited by 57
Airway management in the critically ill: the same, but different
Higgs, A., Cook, T. M., & McGrath, B. A. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew055 · Cited by 54
Airway management outside the operating room: how to better prepare
Brindley, P. G., Beed, M., Law, J. A., Hung, O., Levitan, R., Murphy, M. F., & Duggan, L. V. (2017) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-017-0834-z · Cited by 30
Gokay, P., Tastan, S., & Orhan, M. E. (2016) · Journal of Clinical Nursing · doi:10.1111/jocn.13133 · Cited by 21
Teoh, W. H., & Kristensen, M. S. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew148 · Cited by 21
Sowers, N., & Kovacs, G. (2016) · The Journal of Emergency Medicine · doi:10.1016/j.jemermed.2015.10.010 · Cited by 14
Metadata
- Authors
- Updated by the Committee on Standards and Practice Parameters, Apfelbaum, J. L., Hagberg, C. A., Caplan, R. A., Blitt, C. D., Connis, R. T., Nickinovich, D. G., Hagberg, C. A., The previous update was developed by the American Society of Anesthesiologists Task Force on Difficult Airway Management, Caplan, R. A., Benumof, J. L., Berry, F. A., Blitt, C. D., Bode, R. H., Cheney, F. W., Connis, R. T., Guidry, O. F., Nickinovich, D. G., & Ovassapian, A.
- Venue
- Anesthesiology
- Published
- 2013-02
- Volume
- 118
- Issue
- 2
- Pages
- 251-270
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2132340127
- Cited by
- 2,559
- References
- 49
- FWCI
- 329.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.