CoChat

Characterization of signals and noise rejection with bipolar longitudinal intrafascicular electrodes

Yoshida, K., Stein, R.B. · 1999 · IEEE Transactions on Biomedical Engineering
Cited by 76

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Longitudinal intrafascicular electrodes (LIFE's) are fine electrodes threaded into the extracellular space between axons in peripheral nerves or spinal roots. We are developing these electrodes for application in functional electrical stimulation and in basic physiology. An area of concern in chronic recording application of LIFE's is the possibility of electromyogram and other external noise sources masking the recorded neural signals. We characterized neural signals recorded by LIFE's and confirmed by three independent methods that increasing interelectrode spacing for bipolar LIFE's increases signal amplitude. The spectrum of neural signal from bipolar and monopolar LIFE lies between 300 Hz and 10 kHz. The amplitude of the spectrum increases with increasing interelectrode spacing, although the distribution is not affected. Single unit analysis of LIFE recordings show that they record selectively from units closest to the electrode active site. Units with conduction velocities ranging from 50-120 m/s were identified. Extraneural noise, as stimulus artifact or electromyogram, is much reduced with bipolar LIFE recording, as compared to monopolar recordings. Relative improvement in neural signal to extraneural noise increases with interelectrode spacing up to about 2 mm. Since there is no further improvement beyond 2 mm, we conclude that the preferred interelectrode spacing for bipolar LIFE's is 2 mm.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.740885

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Research works printed but not linked: 15

  1. 10.1385/0-89603-185-3:65 · DOI · Paper page
  2. stein, 1975, principles underlying new methods for chronic neural recording, Can J Neurological Sci, 2, 235, 10.1017/S0317167100020333 · DOI · Paper page
  3. clark, 1968, the extracellular potential field of the single active nerve fiber in a volume conductor, Biophys J, 8, 842, 10.1016/S0006-3495(68)86524-5 · DOI · Paper page
  4. 10.1109/TBME.1974.324406 · DOI · Paper page
  5. stein, 1983, Nerve and Muscle
  6. 10.1016/S0006-3495(76)85719-0 · DOI
  7. 10.1111/j.1525-1594.1997.tb04661.x · DOI · Paper page
  8. 10.1007/BF00233991 · DOI
  9. 10.1007/BF02458045 · DOI
  10. 10.1109/10.301727 · DOI · Paper page
  11. 10.1109/10.481986 · DOI · Paper page
  12. 10.1109/10.125014 · DOI · Paper page
  13. 10.1055/s-2007-1006661 · doi:10.1055/s-2007-1006661
  14. 10.1109/10.277276 · DOI
  15. 10.1007/BF00698791 · DOI

Cited by

Metadata

Authors
Yoshida, K., & Stein, R. B.
Venue
IEEE Transactions on Biomedical Engineering
Published
1999
Volume
46
Issue
2
Pages
226-234
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2098338390
Cited by
76
References
7
FWCI
0.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.