A Review of Non-Invasive Sensory Feedback Methods for Transradial Prosthetic Hands
Open accessThe DOI matches its Crossref record; 109 of the 111 references it cites were found in a registry or an index.
Abstract
Any implant or prosthesis replacing a function or functions of an organ or group of organs should be biologically and sensorily integrated with the human body in order to increase their acceptance with their user. If this replacement is for a human hand, which is an important interface between humans and their environment, the acceptance issue and developing sensory-motor embodiment will be more challenging. Despite progress in prosthesis technologies, 50-60% of hand amputees wear a prosthetic device. One primary reason for the rejection of the prosthetic hands is that there is no or negligibly small feedback or tactile sensation from the hand to the user, making the hands less functional. In fact, the loss of a hand means interrupting the closed-loop sensory feedback between the brain (motor control) and the hand (sensory feedback through the nerves). The lack of feedback requires significant cognitive efforts from the user in order to do basic gestures and daily activities. To this aim, recently, there has been significant development in the provision of sensory feedback from transradial prosthetic hands, to enable the user take part in the control loop and improve user embodiment. Sensory feedback to the hand users can be provided via invasive and non-invasive methods. The latter includes the use of temperature, vibration, mechanical pressure and skin stretching, electrotactile stimulation, phantom limb stimulation, audio feedback, and augmented reality. This paper provides a comprehensive review of the non-invasive methods, performs their critical evaluation, and presents challenges and opportunities associated with the non-invasive sensory feedback methods.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The common issues cited are the unnatural feel, poor functionality, and heavy weight of the device.[19]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [19]
In the citing paper
“Together, e-skin and soft robotics can therefore alleviate problems such as limited functionality,[37] heavy weight,[19] and poor aesthetic design.[31]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [19]
In the citing paper
“For many prostheses, the same sensory information can be acquired through the users’ stump.[19]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [19]
In the citing paper
“Despite the recent improvements to the material, design, and functionality of medical robotics, as well a $6.39 billion dollars market,[23] up to 40% of limb impairment patients still option out of using artificial replacements.[19]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [19]
In the citing paper
“In particular, when e-skin tactile sensing communicates harmful external stimuli to the user, soft robotics can utilize its flexibility and high degree of freedom to efficiently move away and adapt to the scenario.[19,36]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [19]
3 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Pursuing prosthetic electronic skin
Chortos, A., Liu, J., & Bao, Z. (2016) · Nature Materials · doi:10.1038/nmat4671 · Cited by 2,396 · cited 2×
“Biological skin detects these features through four different types of mechanoreceptors in our skin [10], as shown in Figure 1.”
BackgroundCoding and use of tactile signals from the fingertips in object manipulation tasks
Johansson, R. S., & Flanagan, J. R. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2621 · Cited by 2,063 · cited 3×
“Tactile information is required for correction and control of object grasps and manipulations as vision alone does not provide enough of the information required [1].”
BackgroundInfluentialUpper limb prosthesis use and abandonment: A survey of the last 25 years
Biddiss, E. A., & Chau, T. T. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600994581 · Cited by 1,111 · cited 1×
“Prosthetic hand rejection rates are estimated to be as high as 40% [3], with some of user’s reasons for rejection and not wearing a prosthetic device being that they believe it is more functional and easier to receive sensory feedback through their stump without using the prosthetic hand [4].”
BackgroundElectrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827 · cited 2×
“In addition, skin conditions can also influence the comfort and dynamic range of electrotactile stimulation [96].”
BackgroundLiterature Review on Needs of Upper Limb Prosthesis Users
Cordella, F., Ciancio, A. L., Sacchetti, R., Davalli, A., Cutti, A. G., Guglielmelli, E., & Zollo, L. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00209 · Cited by 752 · cited 1×
“Multiple sensory feedback loops (adapted from [106]).”
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751 · cited 1×
“be undertaken on the particular waveform characteristics to improve the induced sensation to the subject to achieve amore natural feeling of pressure, as has been demonstrated in direct nerve stimulation [98].”
BackgroundMechanical design and performance specifications of anthropomorphic prosthetic hands: A review
Belter, J. T., Segil, J. L., Dollar, A. M., & Weir, R. F. (2013) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.10.0188 · Cited by 716 · cited 1×
“Commercial prosthetic hands are further developing in their dexterity and degrees of freedom [103] and will therefore require multiple channels of feedback.”
BackgroundUpper-Limb Prosthetics: Critical Factors in Device Abandonment
Biddiss, E., & Chau, T. (2007) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e3181587f6c · Cited by 645 · cited 1×
“Prosthetic hand rejection rates are estimated to be as high as 40% [3], with some of user’s reasons for rejection and not wearing a prosthetic device being that they believe it is more functional and easier to receive sensory feedback through their stump without using the prosthetic hand [4].”
BackgroundEpidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508 · cited 1×
“Prosthetic users have also shown a strong desire to decrease the need for visual attention to perform functions [2].”
BackgroundOrtiz-Catalan, M., Håkansson, B., & Brånemark, R. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008933 · Cited by 484 · cited 2×
“Although the work involving PNS electrodes has shown some good early results [11], [12], [29], [30], it is still in an early stage of development with limited numbers of test subjects in the laboratory testing that has been undertaken, hence it is not ready for real-life application.”
BackgroundMyoelectric forearm prostheses: State of the art from a user-centered perspective
Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0161 · Cited by 469 · cited 2×
“[26] developed a survey, which examined the requirements for feedback (and control) from a combination of interviews with professionals who regularly interacted with users (occupational therapists,”
BackgroundSensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466 · cited 2×
“[34] published a review on sensory feedback in upper limb prosthetics in 2013.”
BackgroundUpper limb amputees can be induced to experience a rubber hand as their own
Ehrsson, H. H., Rosen, B., Stockselius, A., Ragno, C., Kohler, P., & Lundborg, G. (2008) · Brain · doi:10.1093/brain/awn297 · Cited by 343 · cited 1×
“[6] examined 18 amputees, out of which 12 had a phantom hand map.”
BackgroundOddo, C. M., Raspopovic, S., Artoni, F., Mazzoni, A., Spigler, G., Petrini, F., Giambattistelli, F., Vecchio, F., Miraglia, F., Zollo, L., et al. (2016) · eLife · doi:10.7554/elife.09148 · Cited by 332 · cited 6×
“Nghiem et al. [28] also provided a comprehensive overview of current types of feedback methods and prosthetic hands on market, with a large focus on direct nerve stimulation through the PNS.”
BackgroundMethodInfluentialDavis, T. S., Wark, H. A. C., Hutchinson, D. T., Warren, D. J., O’Neill, K., Scheinblum, T., Clark, G. A., Normann, R. A., & Greger, B. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036001 · Cited by 314 · cited 2×
“Although the work involving PNS electrodes has shown some good early results [11], [12], [29], [30], it is still in an early stage of development with limited numbers of test subjects in the laboratory testing that has been undertaken, hence it is not ready for real-life application.”
BackgroundRubber Hand Illusion under Delayed Visual Feedback
Shimada, S., Fukuda, K., & Hiraki, K. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006185 · Cited by 306 · cited 2×
“[94] and an FMRI study on body ownership by Bekrater-Bodmann et al.”
BackgroundResultXu, B., Akhtar, A., Liu, Y., Chen, H., Yeo, W., Park, S. I., Boyce, B., Kim, H., Yu, J., Lai, H., et al. (2016) · Advanced Materials · doi:10.1002/adma.201504155 · Cited by 304 · cited 3×
“[71] produced a new flexible electrode design that incorporated”
BackgroundThe neural basis of perceived intensity in natural and artificial touch
Graczyk, E. L., Schiefer, M. A., Saal, H. P., Delhaye, B. P., Bensmaia, S. J., & Tyler, D. J. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf5187 · Cited by 258 · cited 6×
“This encoded information is then sent to the CNS, either by direct stimulation of the PNS [11], [12] or CNS [13], [14] using electrode arrays as shown in Figure 1, or via activation of the mechanoreceptors at a location somewhere on the body.”
BackgroundMethodInfluentialElectrocutaneous Stimulation for Sensory Communication in Rehabilitation Engineering
Szeto, A. Y. J., & Saunders, F. A. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324948 · Cited by 223 · cited 2×
“Multiple features can be easily and reliably controlled including the intensity, pulse width, frequency and location of stimulation (with multiple electrodes), which leads to a higher bandwidth being available [95].”
BackgroundClemente, F., D'Alonzo, M., Controzzi, M., Edin, B. B., & Cipriani, C. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2500586 · Cited by 209 · cited 4×
“Although some studies included subjects’ reflections on their use of the prosthetic device with sensory feedback at home [46], [55], the majority of testing, however, has been completed under laboratory conditions, often involving an external computer.”
BackgroundMethodInfluentialAntfolk, C., D'Alonzo, M., Controzzi, M., Lundborg, G., Rosen, B., Sebelius, F., & Cipriani, C. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2217989 · Cited by 194 · cited 4×
“Some of these stimulation techniques have been explored being deployed together [77]–[82]; whereas electrotactile, vibration and mechanical pressure have also been applied to phantom limb stimulation [18]–[23].”
BackgroundMethodInfluentialThe role of feed-forward and feedback processes for closed-loop prosthesis control
Saunders, I., & Vijayakumar, S. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-60 · Cited by 193 · cited 1×
“Using vibration as a source of force feedback has been demonstrated to have improvements over using vision alone as a feedback tool [41], [44], [46], but some literature suggests that this benefit is only visible during inadequate feedforward control [85].”
A review of invasive and non-invasive sensory feedback in upper limb prostheses
Svensson, P., Wijk, U., Björkman, A., & Antfolk, C. (2017) · Expert Review of Medical Devices · doi:10.1080/17434440.2017.1332989 · Cited by 192 · cited 1×
“[31] provided a brief overview of sensors used to detect stimuli, as well as some of the invasive and noninvasive methods used to provide sensory feedback.”
MethodApplications of sensory feedback in motorized upper extremity prosthesis: a review
Schofield, J. S., Evans, K. R., Carey, J. P., & Hebert, J. S. (2014) · Expert Review of Medical Devices · doi:10.1586/17434440.2014.929496 · Cited by 178 · cited 1×
“[33] presented the most recent review that had a major focus on non-invasive feedback methods for prosthetic hands in 2014, which discussed literature up until December 2013.”
BackgroundWheeler, J. W., Bark, K., Savall, J., & Cutkosky, M. R. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039602 · Cited by 168 · cited 2×
“[57] concluded that rotational skin stretch had some benefit in providing position feedback, but only for 1-DOF actuator such as an elbow joint.”
BackgroundA Miniature Vibrotactile Sensory Substitution Device for Multifingered Hand Prosthetics
Cipriani, C., D'Alonzo, M., & Carrozza, M. C. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2173342 · Cited by 164 · cited 2×
“Although it can be as low as 10ms to first detect vibration [5], it can be up to 400ms to reach the desired vibration level and frequency [86].”
BackgroundKim, K., & Colgate, J. E. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2206080 · Cited by 164 · cited 6×
“However, in a study undertaken by Kim and Colgate [17], their subject showed a lower performance picking up a virtual object when receiving shear forces through vibrations at the same time as receiving pressure feedback on grasping force, although this experiment was only performed with one subject with five sets of t…”
BackgroundMethodResultInfluentialDesign and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands
Pylatiuk, C., Kargov, A., & Schulz, S. (2006) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-200604000-00007 · Cited by 156
Stereovision and augmented reality for closed-loop control of grasping in hand prostheses
Marković, M., Dosen, S. S., Cipriani, C., Popović, D. B., & Farina, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/4/046001 · Cited by 154 · cited 1×
“Will not include studies where the hand creates its own feedback loop without involving the user (such as camera to automatically recognise appropriate grip [36], or automatically adjusting grip when slip occurs [37], [38]).”
BackgroundVibro- and Electrotactile User Feedback on Hand Opening for Myoelectric Forearm Prostheses
Witteveen, H. J. B., Droog, E. A., Rietman, J. S., & Veltink, P. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2200678 · Cited by 150 · cited 1×
“Vibrational feedback offers a cheap and lightweight system of feedback that users prefer the sensation over electrotactile feedback [92].”
BackgroundObjectives, criteria and methods for the design of the SmartHand transradial prosthesis
Cipriani, C., Controzzi, M., & Carrozza, M. C. (2009) · Robotica · doi:10.1017/s0263574709990750 · Cited by 150 · cited 1×
“[25] have also suggested”
Chai, G., Sui, X., Li, S., He, L., & Lan, N. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/6/066002 · Cited by 145 · cited 1×
“[22] went on to demonstrate that these sensations were stable for an 11-month period for nine amputees.”
BackgroundExploring Teleimpedance and Tactile Feedback for Intuitive Control of the Pisa/IIT SoftHand
Ajoudani, A., Godfrey, S. B., Bianchi, M., Catalano, M. G., Grioli, G., Tsagarakis, N. G., & Bicchi, A. (2014) · IEEE Transactions on Haptics · doi:10.1109/toh.2014.2309142 · Cited by 144 · cited 2×
“used vibration to provide modality matched feedback on texture information [80], [84].”
MethodClinical applications of penetrating neural interfaces and Utah Electrode Array technologies
Normann, R. A., & Fernandez, E. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/061003 · Cited by 135 · cited 1×
“Normann and Fernandez’s review paper [27] focussed on the variety of nerve arrays available and their use within control and feedback in prosthetic hands.”
BackgroundSensors for Robotic Hands: A Survey of State of the Art
Saudabayev, A., & Varol, H. A. (2015) · IEEE Access · doi:10.1109/access.2015.2482543 · Cited by 129 · cited 3×
“Saudabayev and Varol [32] also provided an overview of the development of sensors for feedback in prosthetic hands.”
BackgroundInfluentialNinu, A., Dosen, S. S., Muceli, S., Rattay, F., Dietl, H., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2318431 · Cited by 129 · cited 1×
“Vibration has typically been used to communicate grasping force, however, a few studies have examined its role in communicating proprioceptive information [42], [50], [83], and some hybrid systems have”
BackgroundCasini, S., Morvidoni, M., Bianchi, M., Catalano, M., Grioli, G., & Bicchi, A. (2015) · 2015 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2015.7353520 · Cited by 122 · cited 1×
“[54] demonstrated the application of distributed haptic force to help a user determine an object as hard, medium or soft.”
BackgroundVibrotactile Stimulation Promotes Embodiment of an Alien Hand in Amputees With Phantom Sensations
D’Alonzo, M., Clemente, F., & Cipriani, C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2337952 · Cited by 119 · cited 4×
“provide an amputee with a higher sense of embodiment in their prosthetic [5] when undertaking simulations modelled after the rubber hand experiment.”
BackgroundMethodInfluentialRotational Skin Stretch Feedback: A Wearable Haptic Display for Motion
Bark, K., Wheeler, J., Shull, P., Savall, J., & Cutkosky, M. (2010) · IEEE Transactions on Haptics · doi:10.1109/toh.2010.21 · Cited by 118 · cited 1×
“[100] examined the use of rotational skin stretch”
BackgroundAntfolk, C., Björkman, A., Frank, S., Sebelius, F., Lundborg, G., & Rosen, B. (2012) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-1001 · Cited by 113
Integrated and flexible multichannel interface for electrotactile stimulation
Strbac, M. D., Belić, M., Isaković, M. S., Kojić, V., Bijelić, G., Popović, I., Radotić, M., Dosen, S. S., Marković, M., Farina, D., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046014 · Cited by 113
Testing a Prosthetic Haptic Feedback Simulator With an Interactive Force Matching Task
Chatterjee, A., Chaubey, P., Martin, J. B., & Thakor, N. V. (2008) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/01.jpo.0000311041.61628.be · Cited by 111 · cited 1×
“Other studies have also demonstrated that the use of vibrotactile feedback results in an improvement in grasping objects [89]–[91].”
BackgroundElectrotactile EMG feedback improves the control of prosthesis grasping force
Schweisfurth, M. A., Markovic, M., Dosen, S., Teich, F., Graimann, B., & Farina, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/5/056010 · Cited by 110 · cited 2×
“Despite their advantages, only approximately half of the electrotactile feedback systems examined use them [60], [64], [66], [68]–[71], which may impact upon their performance.”
BackgroundMethodVibrotactile grasping force and hand aperture feedback for myoelectric forearm prosthesis users
Witteveen, H. J., Rietman, H. S., & Veltink, P. H. (2015) · Prosthetics & Orthotics International · doi:10.1177/0309364614522260 · Cited by 108 · cited 2×
“Vibration has typically been used to communicate grasping force, however, a few studies have examined its role in communicating proprioceptive information [42], [50], [83], and some hybrid systems have”
BackgroundMethodKinesthetic Sensing for the EMG Controlled "Boston Arm"
Mann, R., & Reimers, S. (1970) · IEEE Transactions on Man Machine Systems · doi:10.1109/tmms.1970.299971 · Cited by 108 · cited 1×
“This problem was identified early on in the Boston Arm prosthetic [9] where the authors introduced vibration feedback to give the user position information on the elbow joint of an EMG controlled prosthetic resulting in a performance comparable to that of the cable driven prosthetic.”
BackgroundProviding a sense of touch to prosthetic hands
Nghiem, B. T., Sando, I. C., Gillespie, R. B., McLaughlin, B. L., Gerling, G. J., Langhals, N. B., Urbanchek, M. G., & Cederna, P. S. (2015) · Plastic and Reconstructive Surgery · doi:10.1097/prs.0000000000001289 · Cited by 104 · cited 1×
“[28] also provided a comprehensive overview of current types of feedback methods and prosthetic hands on market, with a large focus on direct nerve stimulation through the PNS.”
BackgroundIsmail, M. A. F., & Shimada, S. (2016) · PLOS ONE · doi:10.1371/journal.pone.0159619 · Cited by 101 · cited 3×
“However, a further refinement study by Ismail and Shimadi [93] suggest that the feedback delay should be less than 200ms to maximise sense of body ownership.”
BackgroundResultBekrater-Bodmann, R., Foell, J., Diers, M., Kamping, S., Rance, M., Kirsch, P., Trojan, J., Fuchs, X., Bach, F., Çakmak, H. K., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0087013 · Cited by 99
Strbac, M. D., Isaković, M. S., Belić, M., Popovic, I., Igor, S., Farina, D., Keller, T., & Dosen, S. S. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2712287 · Cited by 92 · cited 2×
“[107] demonstrated that sensory feedback was greatly beneficial in the beginning of using the prosthetic and learning to reliably manipulate the”
BackgroundEvaluation of force, vibration and thermal tactile feedback in prosthetic limbs
Jimenez, M. C., & Fishel, J. A. (2014) · IEEE Haptics Symposium · doi:10.1109/haptics.2014.6775495 · Cited by 89 · cited 3×
“used vibration to provide modality matched feedback on texture information [80], [84].”
BackgroundMethodThe Rice Haptic Rocker: Skin stretch haptic feedback with the Pisa/IIT SoftHand
Battaglia, E., Clark, J. P., Bianchi, M., Catalano, M. G., Bicchi, A., & O’Malley, M. K. (2017) · IEEE World Haptics Conference (WHC) · doi:10.1109/whc.2017.7989848 · Cited by 87 · cited 1×
“Similarly [99] also demonstrated success in providing position information for a 1-DOF hand.”
BackgroundIdentifying the role of proprioception in upper-limb prosthesis control: Studies on targeted motion
Blank, A. A., Okamura, A. M., & Kuchenbecker, K. J. (2008) · ACM Transactions on Applied Perception · doi:10.1145/1773965.1773966 · Cited by 85
D’Alonzo, M., Dosen, S. S., Cipriani, C., & Farina, D. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2266482 · Cited by 81 · cited 4×
“Some of these stimulation techniques have been explored being deployed together [77]–[82]; whereas electrotactile, vibration and mechanical pressure have also been applied to phantom limb stimulation [18]–[23].”
BackgroundResultInfluentialZhang, D., Xu, H., Shull, P. B., Liu, J., & Zhu, X. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0037-1 · Cited by 69 · cited 3×
“Electrotactile stimulation of the phantom hand [19]–[23] has shown some potential for sensory feedback in a multiple DOF system.”
BackgroundMethodVirtual Grasping: Closed-Loop Force Control Using Electrotactile Feedback
Jorgovanović, N., Dosen, S. S., Djozic, D. J., Krajoski, G., & Farina, D. (2014) · Computational and Mathematical Methods in Medicine · doi:10.1155/2014/120357 · Cited by 65 · cited 3×
“(a) Concentric Electrodes [58] ‘‘Virtual grasping: closed-loop force control using electrotactile feedback’’ by Jorgovanovic et al.”
BackgroundRepeated Training with Augmentative Vibrotactile Feedback Increases Object Manipulation Performance
Stepp, C. E., An, Q., & Matsuoka, Y. (2012) · PLoS ONE · doi:10.1371/journal.pone.0032743 · Cited by 65 · cited 2×
“However, vibrational feedback requires users to undergo training in order to develop the full benefit [88].”
BackgroundChai, G., Zhang, D., & Zhu, X. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2580905 · Cited by 63 · cited 1×
“[108] demonstrated that subjects were able to improve their recognition rate of electrotactile feedback on non-phantom digit”
BackgroundTactile Feedback of Object Slip Facilitates Virtual Object Manipulation
Walker, J. M., Blank, A. A., Shewokis, P. A., & O’Malley, M. K. (2015) · IEEE Transactions on Haptics · doi:10.1109/toh.2015.2420096 · Cited by 62 · cited 1×
“There are a variety of feedback methods that currently have been deployed within literature including the use of temperature [39], [40], vibration [41]–[51], mechanical pressure and skin stretching [15], [16], [52]–[57], electrotactile stimulation [58]–[71], audio feedback [72]–[74], and augmented reality [75], [76].”
BackgroundDrAlonzo, M., Dosen, S. S., Cipriani, C., & Farina, D. (2013) · IEEE Transactions on Haptics · doi:10.1109/toh.2013.52 · Cited by 60
Multichannel electrotactile feedback for simultaneous and proportional myoelectric control
Patel, G. K., Dosen, S., Castellini, C., & Farina, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/5/056015 · Cited by 58 · cited 2×
“[64] used four electrotactile feedback sensors to map the configurations of a 4-DOF prosthetic hand.”
BackgroundMethodHumans Can Integrate Augmented Reality Feedback in Their Sensorimotor Control of a Robotic Hand
Clemente, F., Dosen, S. S., Lonini, L., Marković, M., Farina, D., & Cipriani, C. (2016) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2016.2611998 · Cited by 58 · cited 2×
“[76] also examined the use of augmented reality for sensory feedback for prosthetic devices.”
BackgroundVidal, G. W. V., Rynes, M. L., Kelliher, Z., & Goodwin, S. J. (2016) · Scientifica · doi:10.1155/2016/8956432 · Cited by 57 · cited 4×
“have examined the role of implants into the CNS [13], [14].”
BackgroundMethodInfluentialElectrotactile feedback improves performance and facilitates learning in the routine grasping task
Isaković, M. S., Belić, M., Strbac, M. D., Popović, I., Dosen, S. S., Farina, D., & Keller, T. (2016) · European Journal of Translational Myology · doi:10.4081/ejtm.2016.6069 · Cited by 57 · cited 1×
“[59] also demonstrated that using electrotactile feedback helped users learn to regulate myoelectric control of grasping force quicker.”
BackgroundArtificial Proprioceptive Feedback for Myoelectric Control
Tobias Pistohl, A., Joshi, D., Ganesh, G., Andrew, J. O., & Nazarpour, K. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2355856 · Cited by 56 · cited 1×
“[105] also examined the role of proprioceptive feedback.”
BackgroundTime-division multiplexing for myoelectric closed-loop control using electrotactile feedback
Dosen, S., Schaeffer, M.-C., & Farina, D. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-138 · Cited by 55 · cited 1×
“One approach undertaken is time-division multiplexing for myoelectric control and electrotactile stimulation [69].”
MethodNeural correlates of the rubber hand illusion in amputees: A report of two cases
Schmalzl, L., Kalckert, A., Ragnö, C., & Ehrsson, H. H. (2014) · Neurocase · doi:10.1080/13554794.2013.791861 · Cited by 53 · cited 2×
“In addition, another study [7] examined two amputees undergoing a functional MRI scan whilst completing the rubber hand illusion test.”
BackgroundAntfolk, C., Cipriani, C., Carrozza, M. C., Balkenius, C., Björkman, A., Lundborg, G., Rosén, B., & Sebelius, F. (2012) · Disability and Rehabilitation Assistive Technology · doi:10.3109/17483107.2012.713435 · Cited by 53 · cited 3×
“There are a variety of feedback methods that currently have been deployed within literature including the use of temperature [39], [40], vibration [41]–[51], mechanical pressure and skin stretching [15], [16], [52]–[57], electrotactile stimulation [58]–[71], audio feedback [72]–[74], and augmented reality [75], [76].”
BackgroundMethodGLIMPSE: Google Glass interface for sensory feedback in myoelectric hand prostheses
Marković, M., Karnal, H., Graimann, B., Farina, D., & Dosen, S. S. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa620a · Cited by 53 · cited 2×
“[75] used Google glasses to communicate the aperture angle, contact time, grasping force and EMG strength for sensory feedback of a prosthetic hand to its user.”
BackgroundMethodStepp, C. E., & Matsuoka, Y. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2170856 · Cited by 48 · cited 1×
“Other studies have also demonstrated that the use of vibrotactile feedback results in an improvement in grasping objects [89]–[91].”
BackgroundXu, H., Zhang, D., Huegel, J. C., Xu, W., & Zhu, X. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2478153 · Cited by 47 · cited 2×
“(b) Four pairs of electrodes [62] 2016 IEEE.”
BackgroundGodfrey, S. B., Bianchi, M., Bicchi, A., & Santello, M. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591957 · Cited by 46 · cited 3×
“[15] also examined the use of a feedback band around the arm to provide information to users on grasping force.”
BackgroundPassive Mechanical Skin Stretch for Multiple Degree-of-Freedom Proprioception in a Hand Prosthesis
Akhtar, A., Nguyen, M., Wan, L., Boyce, B., Slade, P., & Bretl, T. W. (2014) · Lecture notes in computer science · doi:10.1007/978-3-662-44196-1_16 · Cited by 44 · cited 1×
“[56] explored the use of linear skin stretch on the forearm to provide feedback on the position of fingers.”
BackgroundEffects of kinematic vibrotactile feedback on learning to control a virtual prosthetic arm
Hasson, C. J., & Manczurowsky, J. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0025-5 · Cited by 43 · cited 5×
“However, although only mentioned in a vibrotactile study by Hasson and Manczurowky [50], haptic drivers can be implemented to decrease start up times of vibration motors.”
BackgroundInfluentialDevelopment and Real World Use of a Vibratory Haptic Feedback System for Upper-Limb Prosthetic Users
Chou, T. G. R., Daly, W. K., Austin, R., Chaubey, P., & Boone, D. A. (2016) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0000000000000107 · Cited by 42 · cited 2×
“Using vibration as a source of force feedback has been demonstrated to have improvements over using vision alone as a feedback tool [41], [44], [46], but some literature suggests that this benefit is only visible during inadequate feedforward control [85].”
BackgroundSensory qualities of the phantom hand map in the residual forearm of amputees
Björkman, A., Wijk, U., Antfolk, C., Björkman‐Burtscher, I. M., & Rosen, B. (2016) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-2074 · Cited by 40 · cited 2×
“Examples of Phantom Hand Maps and their corresponding Phantom digit locations [101] from ‘‘Sensory qualities of the phantom hand map in the residual forearm of amputees’’ by Bjorkman et al.”
BackgroundAn Empirical Evaluation of Force Feedback in Body-Powered Prostheses
Brown, J. D., Kunz, T. S., Gardner, D., Shelley, M. K., Davis, A. J., & Gillespie, R. B. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2554061 · Cited by 40 · cited 1×
“However, with myoelectric prosthetic devices, this indirect feedback pathway no longer exists [8].”
BackgroundUpper extremity prosthesis user perspectives on unmet needs and innovative technology
Benz, H. L., Yao, J., Rose, L., Olgac, O., Karen, K., Saha, A., & Civillico, E. F. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7590696 · Cited by 39 · cited 3×
“[24] H. L. Benz et al., ‘‘Upper extremity prosthesis user perspectives on unmet needs and innovative technology,’’ in Proc.”
BackgroundInfluentialChai, G., Li, S., Sui, X., Mei, Z., He, L., Zhong, C. L., Wang, J., Zhang, D. G., Zhu, X., & Lan, N. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6695924 · Cited by 36 · cited 1×
“Transcutaneous Electrical Nerve Stimulation (TENS) can induce sensations in these phantom digit locations for all fingers [20].”
BackgroundPerruchoud, D., Pisotta, I., Carda, S., Murray, M. M., & Ionta, S. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/041001 · Cited by 35
Sensory Feedback using Electrical Stimulation of the Tactile Sense
Szeto, A. Y. J., & Riso, R. R. (2018) · Routledge eBooks · doi:10.1201/9780203741009-3 · Cited by 33 · cited 2×
“sensation [95], [97] and can reduce the resulting noise on the EMG used for myoelectric control [70].”
BackgroundRaveh, E., Friedman, J., & Portnoy, S. (2017) · Assistive Technology · doi:10.1080/10400435.2017.1323809 · Cited by 31 · cited 1×
“[49] examined the effect of vibrotactile feedback on the visual attention required in performing tasks with a prosthetic.”
BackgroundA sensory feedback system for prosthetic hand based on evoked tactile sensation
Liu, X., Chai, G., Qu, H., & Lan, N. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318898 · Cited by 28 · cited 1×
“[21] further expanded on this work by showing that these signals could be induced by pressing on a tactile sensor on each prosthetic finger.”
BackgroundYamada, H., Yamanoi, Y., Wakita, K., & Kato, R. (2016) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2016.7487537 · Cited by 28 · cited 3×
“There are a variety of feedback methods that currently have been deployed within literature including the use of temperature [39], [40], vibration [41]–[51], mechanical pressure and skin stretching [15], [16], [52]–[57], electrotactile stimulation [58]–[71], audio feedback [72]–[74], and augmented reality [75], [76].”
BackgroundClosed-Loop Vibratory Haptic Feedback in Upper-Limb Prosthetic Users
Chaubey, P., Chou, T. G. R., Daly, W. K., & Boone, D. A. (2014) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0000000000000030 · Cited by 26 · cited 1×
“This research group also examined the effect of varying pulse frequency in vibrotactile feedback to communicate grasping force [45].”
BackgroundTowards prosthetic systems providing comprehensive tactile feedback for utility and embodiment
Hartmann, C., Linde, J., Dosen, S. S., Farina, D., Seminara, L., Pinna, L., Valle, M., & Capurro, M. (2014) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2014.6981802 · Cited by 26 · cited 2×
“Despite their advantages, only approximately half of the electrotactile feedback systems examined use them [60], [64], [66], [68]–[71], which may impact upon their performance.”
BackgroundVibrotactile stimulation for 3D printed prosthetic hand
Nabeel, M., Aqeel, K., Ashraf, M. N., Awan, M. I., & Khurram, M. (2016) · doi:10.1109/icrai.2016.7791254 · Cited by 26 · cited 2×
“(b) Coin Vibration Motors [43] 2016 IEEE.”
MethodAuditory display as a prosthetic hand sensory feedback for reaching and grasping tasks
Gonzalez-Vargas, J. E., Suzuki, H., Natsumi, N., Sekine, M., & Yu, W. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346297 · Cited by 24 · cited 2×
“[74] utilised triads to communicate the movement of a robotic hand.”
BackgroundMethodThe Upper-limb Amputees. A Survey and Trends in Kinki Area of Japan.
Kawamura, J., Fukui, N., NAKAGAWA, M., 藤下, 武., AOYAMA, T., & Furukawa, H. (1999) · リハビリテーション医学 : 日本リハビリテーション医学会誌 · doi:10.2490/jjrm1963.36.384 · Cited by 24
Two-channel electrotactile stimulation for sensory feedback of fingers of prosthesis
Choi, K., Kim, P., Kim, K.-S., & Kim, S. (2016) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2016.7759191 · Cited by 22 · cited 2×
“[63] demonstrated that subjects could distin-”
BackgroundMorita, T., Kikuchi, T., & Ishii, C. (2016) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2016.p0361 · Cited by 19 · cited 1×
“[53] used a winding belt motor on the upper arm to communicate grasping force”
MethodClemente, F., & Cipriani, C. (2014) · IEEE Haptics Symposium · doi:10.1109/haptics.2014.6775518 · Cited by 18 · cited 1×
“Combining mechanical pressure and vibration has also been explored [79], but only an experimental prototype was built, without any testing performed on subjects.”
BackgroundLi, P., Chai, G., Zhu, K., Lan, N., & Sui, X. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319118 · Cited by 18 · cited 5×
“Although the invasive methods of targeted reinnervation [17] and nerve electrode interfaces [11], [12] communicate through somatotopical feedback, non-invasive methods can also apply mechanotactile, electrotactile, vibrotactile or temperature feedback to phantom handmaps [18]–[23] to produce somatotopical feedback.”
BackgroundMethodInfluentialWireless Temperature Sensing Cosmesis for Prosthesis
Cho, Y., Liang, K., Folowosele, F. O., Miller, B., & Thakor, N. V. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428497 · Cited by 17 · cited 2×
“[39] used a disguised temperature sensor in a prosthetic hand to sense temperature and wirelessly transmit the measured tempera-”
BackgroundMethodUeda, Y., & Ishii, C. (2016) · International Conference on Advanced Mechatronic Systems · doi:10.1109/icamechs.2016.7813497 · Cited by 17 · cited 4×
“[53] T. Morita, T. Kikuchi, and C. Ishii, ‘‘Development of sensory feedback device for myoelectric prosthetic hand to provide hardness of objects to users,’’ J. Robot.”
BackgroundMethodInfluentialNoise cancellation for electrotactile sensory feedback of myoelectric forearm prostheses
Jiang, L., Huang, Q., Zhao, J., Yang, D., Fan, S., & Liu, H. (2014) · IEEE International Conference on Information and Automation (ICIA) · doi:10.1109/icinfa.2014.6932807 · Cited by 16 · cited 2×
“sensation [95], [97] and can reduce the resulting noise on the EMG used for myoelectric control [70].”
BackgroundA closed-loop tactor frequency control system for vibrotactile feedback
Cohen, J., Niwa, M., Lindeman, R. W., Noma, H., Yanagida, Y., & Hosaka, K. (2005) · CHI Conference Extended Abstracts on Human Factors in Computing Systems (CHI EA) · doi:10.1145/1056808.1056900 · Cited by 15 · cited 1×
“it has also been suggested that perception of vibrational frequency can be affected by how tightly a vibration motor is attached [87], which raises difficulties in predictive and reliable sensory feedback.”
BackgroundFranceschi, M., Seminara, L., Pinna, L., Dosen, S. S., Farina, D., & Valle, M. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319407 · Cited by 15 · cited 1×
“Franceschi et al.[67] investigated possibilities of communicating information from artificial skin by translating information from 64 pressure sensors into 32 electrotactile electrodes on the subject’s arm.”
BackgroundShi, P. A., & Shen, X. (2015) · International Conference on Measuring Technology and Mechatronics Automation (ICMTMA) · doi:10.1109/icmtma.2015.236 · Cited by 14
Motamedi, M. R., Otis, M. J.-D., & Duchaine, V. (2017) · Journal of Biomechanical Engineering · doi:10.1115/1.4036417 · Cited by 14 · cited 2×
“Some of these stimulation techniques have been explored being deployed together [77]–[82]; whereas electrotactile, vibration and mechanical pressure have also been applied to phantom limb stimulation [18]–[23].”
BackgroundTactile display on the remaining hand for unilateral hand amputees
Li, T., Huang, H., Antfolk, C., Justiz, J., & Koch, V. M. (2016) · Current Directions in Biomedical Engineering · doi:10.1515/cdbme-2016-0089 · Cited by 11 · cited 1×
“[48] examined the use of vibrators on a sports glove on the remaining hand to provide force feedback from the prosthetic.”
Slippage control for a smart prosthetic hand prototype via modified tactile sensory feedback
Sriram, G. A., Jensen, A. N., & Chiu, S. C. (2014) · IEEE International Conference on Electro Information Technology · doi:10.1109/eit.2014.6871766 · Cited by 10 · cited 1×
“Will not include studies where the hand creates its own feedback loop without involving the user (such as camera to automatically recognise appropriate grip [36], or automatically adjusting grip when slip occurs [37], [38]).”
BackgroundProviding contact sensory feedback for upper limb robotic prosthesis
Aziziaghdam, M., & Samur, E. (2014) · IEEE Haptics Symposium · doi:10.1109/haptics.2014.6775519 · Cited by 8 · cited 4×
“C. MECHANOTACTILE PRESSURE Preliminary tests conducted by Aziziaghdam and Samur [52] showed that an object could be identified as either hard or soft from the acceleration response obtained whilst tapping an object.”
BackgroundInfluentialWang, H., Fang, P., Tian, L., Zheng, Y., Zhou, H. D., Li, G., & Zhang, X. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319114 · Cited by 8 · cited 1×
“[102] suggested that the distribution of phantom digits is located along the stump nerves.”
BackgroundObject discrimination using optimized multi-frequency auditory cross-modal haptic feedback
Gibson, A. E., & Artemiadis, P. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6945118 · Cited by 8 · cited 2×
“Gibson and Artemiadis [73] showed that a subject could use auditory feedback alone to pick up objects with a robotic hand.”
BackgroundTowards dynamic object manipulation with tactile sensing for prosthetic hands
Cortez, W. S., Oetomo, D., Manzie, C. G., & Choong, P. (2016) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2016.7759196 · Cited by 8 · cited 1×
“Will not include studies where the hand creates its own feedback loop without involving the user (such as camera to automatically recognise appropriate grip [36], or automatically adjusting grip when slip occurs [37], [38]).”
BackgroundElectro-tactile Feedback System for a Prosthetic Hand
Pamungkas, D. S., & Ward, K. (2015) · Research Online (University of Wollongong) · Cited by 8
A Miniature Multimodal Actuator for Effective Tactile Feedback: Design and Characterization
Li, T., Huang, H., Justiz, J., & Koch, V. M. (2016) · Procedia Engineering · doi:10.1016/j.proeng.2016.11.457 · Cited by 7 · cited 2×
“[81] also presented a new design for”
BackgroundAudio sensory substitution for human-in-the-loop force feedback of upper limb prosthetics
Wilson, S., & Dirven, S. (2016) · International Conference on Mechatronics and Machine Vision in Practice (M2VIP) · doi:10.1109/m2vip.2016.7827290 · Cited by 4 · cited 4×
“Wilson and Dirven [72] demonstrated the potential of deploying audio to communicate sensory feedback from a prosthesis.”
BackgroundInfluentialTactile to vibrotactile sensory feedback interface for prosthethic hand users
Hanif, N. H. H. M., Hashim, N. N. W. N., Chappell, P. H., White, N. M., & Cranny, A. (2016) · IEEE-EMBS Conference on Biomedical Engineering and Sciences · doi:10.1109/iecbes.2016.7843467 · Cited by 4
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Skin‐Integrated Vibrohaptic Interfaces for Virtual and Augmented Reality
Jung, Y. H., Kim, J., & Rogers, J. A. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202008805 · Cited by 147
Kourtesis, P., Argelaguet, F., Vizcay, S., Marchal, M., & Pacchierotti, C. (2022) · IEEE Transactions on Haptics · doi:10.1109/toh.2022.3189866 · Cited by 144
“A personalized calibration may prevent these undesirable effects by adjusting the intensity and duration of the electrotactile feedback to the personal sensational and discomfort thresholds of the user [22].”
BackgroundInfluentialA Review of Myoelectric Control for Prosthetic Hand Manipulation
Chen, Z., Min, H., Wang, D., Xia, Z., Sun, F., & Fang, B. (2023) · Biomimetics · doi:10.3390/biomimetics8030328 · Cited by 149
“Several prior reviews have extensively summarized the methods employed in providing feedback to users of prosthetic hands [88–90].”
MethodCurrent Solutions and Future Trends for Robotic Prosthetic Hands
Mendez, V., Iberite, F., Shokur, S., & Micera, S. (2021) · Annual Review of Control Robotics and Autonomous Systems · doi:10.1146/annurev-control-071020-104336 · Cited by 126
Metadata
- Authors
- Stephens-Fripp, B., Alici, G., & Mutlu, R.
- Affiliations
- University of Wollongong (AU)
- Venue
- IEEE Access
- Published
- 2018
- Volume
- 6
- Pages
- 6878-6899
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W2783748062
- Semantic Scholar
- acfb93ebd449ba2ef5f696034bc6250abff3d3a7
- Cited by
- 210
- References
- 111
- Citations by year
- 2026: 15 · 2025: 18 · 2024: 22 · 2023: 34 · 2022: 34 · 2021: 31 · 2020: 25 · 2019: 24 · 2018: 7
- FWCI
- 8.71
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- IEEE Access (publishedVersion)
- Research Online (University of Wollongong) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion)
- Funders
- Australian Government Research Training Program Scholarship
- ARC Centre of Excellence for Electromaterials Science (CE140100012)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- tactile feedback, temperature feedback, vibration feedback, skin stretching, electrocutaneous stimulation, audio feedback, augmented reality, prosthesis acceptance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.