The DOI matches its Crossref record; 77 of the 77 references it cites were found in a registry or an index.
Microelectrodes, Microelectronics, and Implantable Neural Microsystems
Abstract
Lithographically defined microelectrode arrays now permit high-density recording and stimulation in the brain and are facilitating new insights into the organization and function of the central nervous system. They will soon allow more detailed mapping of neural structures than has ever before been possible, and capabilities for highly localized drug-delivery are being added for treating disorders such as severe epilepsy. For chronic neuroscience and neuroprosthesis applications, the arrays are being used in implantable microsystems that provide embedded signal processing and wireless data transmission to the outside world. A 64-channel microsystem amplifies the neural signals by 60 dB with a user-programmable bandwidth and an input-referred noise level of 8$\mu{\hbox{V}}_{\rm rms}$before processing the signals digitally. The channels can be scanned at a rate of 62.5 kS/s, and signals above a user-specified biphasic threshold are transmitted wirelessly to the external world at 2 Mbps. Individual channels can also be digitized and viewed externally at high resolution to examine spike waveforms. The microsystem dissipates 14.14 mW from 1.8 V and measures 1.4$\times$1.55 cm$^2$.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Silicon as a mechanical material
Petersen, K. E. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12331 · Cited by 2,902
Electrical Stimulation of the Subthalamic Nucleus in Advanced Parkinson's Disease
Limousin, P., Krack, P., Pollak, P., Benazzouz, A., Ardouin, C., Hoffmann, D., & Benabid, A.-L. (1998) · New England Journal of Medicine · doi:10.1056/nejm199810153391603 · Cited by 1,853
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170 · cited 1×
“Work on visual prostheses began with Brindley’s early efforts [ 5 ], but by the late 1960s, a program to develop a cortical prosthesis for the blind was also under way under Dobelle at the University of Utah [6], [7].”
BackgroundBiran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
A Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System
Harrison, R., Watkins, P., Kier, R., Lovejoy, R., Black, D., Normann, R., & Solzbacher, F. (2006) · 2006 IEEE International Solid State Circuits Conference - Digest of Technical Papers · doi:10.1109/isscc.2006.1696288 · Cited by 731
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Self-citation
Cited by
Microneedles for drug and vaccine delivery
Kim, Y.-C., Park, J.-H., & Prausnitz, M. R. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.04.005 · Cited by 1,760
An Integrated Brain-Machine Interface Platform With Thousands of Channels
Musk, E., & Neuralink (2019) · Journal of Medical Internet Research · doi:10.2196/16194 · Cited by 1,206
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
Highly Conformable Conducting Polymer Electrodes for In Vivo Recordings
Khodagholy, D., Doublet, T., Gurfinkel, M., Quilichini, P., Ismailova, E., Leleux, P., Herve, T., Sanaur, S., Bernard, C., & Malliaras, G. G. (2011) · Advanced Materials · doi:10.1002/adma.201102378 · Cited by 373
Nanotools for Neuroscience and Brain Activity Mapping
Alivisatos, A. P., Andrews, A. M., Boyden, E. S., Chun, M., Church, G. M., Deisseroth, K., Donoghue, J. P., Fraser, S. E., Lippincott-Schwartz, J., Looger, L. L., et al. (2013) · ACS Nano · doi:10.1021/nn4012847 · Cited by 356
Tools for Probing Local Circuits: High-Density Silicon Probes Combined with Optogenetics
Buzsáki, G., Stark, E., Berényi, A., Khodagholy, D., Kipke, D. R., Yoon, E., & Wise, K. D. (2015) · Neuron · doi:10.1016/j.neuron.2015.01.028 · Cited by 334
Self-citationSoft Materials in Neuroengineering for Hard Problems in Neuroscience
Jeong, J.-W., Shin, G., Park, S. I., Yu, K. J., Xu, L., & Rogers, J. A. (2015) · Neuron · doi:10.1016/j.neuron.2014.12.035 · Cited by 333
Silicon electronics on silk as a path to bioresorbable, implantable devices
Kim, D.-H., Kim, Y.-S., Amsden, J., Panilaitis, B., Kaplan, D. L., Omenetto, F. G., Zakin, M. R., & Rogers, J. A. (2009) · Applied Physics Letters · doi:10.1063/1.3238552 · Cited by 295
Multiplexed, High Density Electrophysiology with Nanofabricated Neural Probes
Du, J., Blanche, T. J., Harrison, R. R., Lester, H. A., & Masmanidis, S. C. (2011) · PLoS ONE · doi:10.1371/journal.pone.0026204 · Cited by 231
“Microelectromechanical systems (MEMS) based electrode arrays are increasingly being used to address this challenge [10,11].”
BackgroundImplantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175
Han, D., Zheng, Y., Rajkumar, R., Dawe, G. S., & Je, M. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2298860 · Cited by 147
“With the advanced micro-electromechanical system (MEMS) technology, a few hundreds of neural microelectrodes [1], [2] can be integrated into a tiny volume of silicon chip and implanted into cerebral cortex to detect neural potentials in a wide range of applications.”
BackgroundThe Argo: a high channel count recording system for neural recording in vivo
Sahasrabuddhe, K., Khan, A. A., Singh, A. P., Stern, T. M., Ng, Y., Tadić, A., Orel, P., LaReau, C., Pouzzner, D., Nishimura, K., et al. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abd0ce · Cited by 124
Recent Advances in Neural Recording Microsystems
Gosselin, B. (2011) · Sensors · doi:10.3390/s110504572 · Cited by 138
Translating the Brain-Machine Interface
Thakor, N. V. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007303 · Cited by 128
Novel multi-sided, microelectrode arrays for implantable neural applications
Seymour, J. P., Langhals, N. B., Anderson, D. J., & Kipke, D. R. (2011) · Biomedical Microdevices · doi:10.1007/s10544-011-9512-z · Cited by 95
Silk-Backed Structural Optimization of High-Density Flexible Intracortical Neural Probes
Wu, F., Tien, L. W., Chen, F., Berke, J. D., Kaplan, D. L., & Yoon, E. (2015) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2375326 · Cited by 80
Jeon, M., Cho, J., Kim, Y. K., Jung, D., Yoon, E.-S., Shin, S., & Cho, I.-J. (2014) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/24/2/025010 · Cited by 61
Liu, X., Demosthenous, A., Vanhoestenberghe, A., Jiang, D., & Donaldson, N. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2174360 · Cited by 39
A multi-shank silk-backed parylene neural probe for reliable chronic recording
Wu, F., Tien, L., Chen, F., Kaplan, D., Berke, J., & Yoon, E. (2013) · 2013 Transducers & Eurosensors XXVII: The 17th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS & EUROSENSORS XXVII) · doi:10.1109/transducers.2013.6626910 · Cited by 24
Walker, R. M., Rieth, L., Iyer, S. S., Bajwa, A. A., Silver, J., Ahmed, T., Tasneem, N., Sharma, M., & Gardner, A. T. (2017) · 2017 IEEE 60th International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas.2017.8053106 · Cited by 7
Metadata
- Authors
- Wise, K. D., Sodagar, A. M., Yao, Y., Gulari, M. N., Perlin, G. E., & Najafi, K.
- Venue
- Proceedings of the IEEE
- Published
- 2008-07
- Volume
- 96
- Issue
- 7
- Pages
- 1184-1202
- ISSN
- 0018-9219 (ISSN-L)
- 1558-2256
- OpenAlex
- W2121570266
- Cited by
- 335
- References
- 77
- FWCI
- 10.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.