The DOI matches its Crossref record; 77 of the 77 references it cites were found in a registry or an index.
Microelectrodes, Microelectronics, and Implantable Neural Microsystems
Abstract
Lithographically defined microelectrode arrays now permit high-density recording and stimulation in the brain and are facilitating new insights into the organization and function of the central nervous system. They will soon allow more detailed mapping of neural structures than has ever before been possible, and capabilities for highly localized drug-delivery are being added for treating disorders such as severe epilepsy. For chronic neuroscience and neuroprosthesis applications, the arrays are being used in implantable microsystems that provide embedded signal processing and wireless data transmission to the outside world. A 64-channel microsystem amplifies the neural signals by 60 dB with a user-programmable bandwidth and an input-referred noise level of 8$\mu{\hbox{V}}_{\rm rms}$before processing the signals digitally. The channels can be scanned at a rate of 62.5 kS/s, and signals above a user-specified biphasic threshold are transmitted wirelessly to the external world at 2 Mbps. Individual channels can also be digitized and viewed externally at high resolution to examine spike waveforms. The microsystem dissipates 14.14 mW from 1.8 V and measures 1.4$\times$1.55 cm$^2$.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Silicon as a mechanical material
Petersen, K. E. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12331 · Cited by 2,902
Electrical Stimulation of the Subthalamic Nucleus in Advanced Parkinson's Disease
Limousin, P., Krack, P., Pollak, P., Benazzouz, A., Ardouin, C., Hoffmann, D., & Benabid, A.-L. (1998) · New England Journal of Medicine · doi:10.1056/nejm199810153391603 · Cited by 1,853
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170 · cited 1×
“Work on visual prostheses began with Brindley’s early efforts [ 5 ], but by the late 1960s, a program to develop a cortical prosthesis for the blind was also under way under Dobelle at the University of Utah [6], [7].”
BackgroundBiran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
A Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System
Harrison, R., Watkins, P., Kier, R., Lovejoy, R., Black, D., Normann, R., & Solzbacher, F. (2006) · 2006 IEEE International Solid State Circuits Conference - Digest of Technical Papers · doi:10.1109/isscc.2006.1696288 · Cited by 731
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Self-citationFlexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
Schwartz, A. B. (2004) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.27.070203.144233 · Cited by 559
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544
Self-citationSurface modification of neural recording electrodes with conducting polymer/biomolecule blends
Cui, X., Lee, V. A., Raphael, Y., Wiler, J. A., Hetke, J. F., Anderson, D. J., & Martin, D. C. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200108)56:2<261::aid-jbm1094>3.0.co;2-i · Cited by 530
The electrical properties of metal microelectrodes
Robinson, D. A. (1968) · Proceedings of the IEEE · doi:10.1109/proc.1968.6458 · Cited by 464
Dobelle, W. H., Mladejovsky, M. G., & Girvin, J. P. (1974) · Science · doi:10.1126/science.183.4123.440 · Cited by 440
Retinal Prosthesis for the Blind
Margalit, E., Maia, M., Weiland, J. D., Greenberg, R. J., Fujii, G. Y., Torres, G., Piyathaisere, D. V., O'Hearn, T. M., Liu, W., Lazzi, G., et al. (2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00311-9 · Cited by 427
Reconstructing the Engram: Simultaneous, Multisite, Many Single Neuron Recordings
Nicolelis, M. A. L., Ghazanfar, A. A., Faggin, B. M., Votaw, S., & Oliveira, L. M. O. (1997) · Neuron · doi:10.1016/s0896-6273(00)80295-0 · Cited by 375
Spike Detection Using the Continuous Wavelet Transform
Nenadic, Z., & Burdick, J. W. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.839800 · Cited by 375
An implantable multielectrode array with on-chip signal processing
Najafi, K., & Wise, K. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052646 · Cited by 310
Self-citationA high-yield IC-compatible multichannel recording array
Najafi, K., Wise, K. D., & Mochizuki, T. (1985) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1985.22102 · Cited by 301
Self-citationA multichannel neural probe for selective chemical delivery at the cellular level
Chen, J., Wise, K. D., Hetke, J. F., & Bledsoe, S. C. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.605435 · Cited by 280
Self-citationWavelet preprocessing for automated neural network detection of EEG spikes
Kalayci, T., & Ozdamar, O. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.376754 · Cited by 264
Chronic neural stimulation with thin-film, iridium oxide electrodes
Weiland, J. D., & Anderson, D. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.846685 · Cited by 262
A high-yield microassembly structure for three-dimensional microelectrode arrays
Bai, Q., Wise, K. D., & Anderson, D. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.827288 · Cited by 245
Self-citationA three-dimensional neural recording microsystem with implantable data compression circuitry
Olsson, R. H., & Wise, K. D. (2005) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2005.858479 · Cited by 245
Self-citationBeebe, X., & Rose, T. L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.2122 · Cited by 219
Wireless multichannel biopotential recording using an integrated FM telemetry circuit
Mohseni, P., Najafi, K., Eliades, S. J., & Wang, X. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.853625 · Cited by 219
Self-citationSingle-unit neural recording with active microelectrode arrays
Bai, Q., & Wise, K. D. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.936367 · Cited by 215
Self-citationA 32-site neural recording probe fabricated by DRIE of SOI substrates
Norlin, P., Kindlundh, M., Mouroux, A., Yoshida, K., & Hofmann, U. G. (2002) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/12/4/312 · Cited by 184
OlssonIII, R. H., Buhl, D. L., Sirota, A. M., Buzsaki, G., & Wise, K. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847540 · Cited by 181
Self-citationAn implantable CMOS circuit interface for multiplexed microelectrode recording arrays
Ji, J., & Wise, K. D. (1992) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.121568 · Cited by 173
Self-citationLepselter, M. P. (1966) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1966.tb00018.x · Cited by 163
A Low-Capacitance Multielectrode Probe for Use in Extracellular Neurophysiology
Wise, K. D., & Angell, J. B. (1975) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1975.324562 · Cited by 159
Self-citationInformation conveyed through brain-control: cursor versus robot
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814451 · Cited by 147
Strength characterization of silicon microprobes in neurophysiological tissues
Najafi, K., & Hetke, J. F. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55638 · Cited by 146
Self-citationA Fully Integrated Mixed-Signal Neural Processor for Implantable Multichannel Cortical Recording
Sodagar, A. M., Wise, K. D., & Najafi, K. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.894986 · Cited by 134
Self-citationKewley, D. T., Hills, M. D., Borkholder, D. A., Opris, I. E., Maluf, N. I., Storment, C. W., Bower, J. M., & Kovacs, G. T. A. (1997) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(97)80221-x · Cited by 119
Neuronal Activity in Cortical and Thalamic Networks
Verzeano, M., & Negishi, K. (1960) · The Journal of General Physiology · doi:10.1085/jgp.43.6.177 · Cited by 116
A micromachined silicon depth probe for multichannel neural recording
Yoon, T. H., Hwang, E. J., Shin, D. Y., Park, S. I., Oh, S., Jung, S. C., Shin, H. C., & Kim, S. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.855936 · Cited by 109
A 32-Site 4-Channel High-Density Electrode Array for a Cochlear Prosthesis
Bhatti, P. T., & Wise, K. D. (2006) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.884862 · Cited by 108
Self-citationThin-Film Multiple Electrode Probes: Possibilities and Limitations
Prohaska, O. J., Olcaytug, F., Pfundner, P., & Dragaun, H. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325894 · Cited by 104
A 64-site multishank CMOS low-profile neural stimulating probe
Kim, C., & Wise, K. D. (1996) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.535406 · Cited by 103
Self-citationThe past, present, and future of cochlear prostheses
Spelman, F. A. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.765186 · Cited by 101
Interictal Spike Detection Using the Walsh Transform
Adjouadi, M., Sanchez, D., Cabrerizo, M., Ayala, M., Jayakar, P., Yaylali, I., & Barreto, A. B. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826642 · Cited by 95
Multisite microprobes for neural recordings
Blum, N. A., Carkhuff, B. G., Charles, H. K., Edwards, R. L., & Meyer, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68211 · Cited by 93
High-resolution spatio-temporal mapping of visual pathways using multi-electrode arrays
Normann, R. A., Warren, D. J., Ammermüller, J., Fernández, E., & Guillory, S. G. (2001) · Vision Research · doi:10.1016/s0042-6989(00)00273-x · Cited by 90
Implantable multichannel electrode array based on soi technology
Cheung, K. C., Djupsund, K., Dan, Y., & Lee, L. P. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.809962 · Cited by 81
Electrical Stimulation of Acoustical Nerve and Inferior Colliculus: Results in Man
Simmons, F. B., Mongeon, C. J., LEWIS, W. R., & Huntington, D. A. (1964) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1964.00750030572003 · Cited by 77
A Practical 24 Channel Microelectrode for Neural Recording in Vivo
Kuperstein, M., & Whittington, D. A. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324702 · Cited by 74
Focally injected adenosine prevents seizures in the rat
Anschel, D. J., Ortega, E. L., Kraus, A. C., & Fisher, R. S. (2004) · Experimental Neurology · doi:10.1016/j.expneurol.2004.07.017 · Cited by 60
Electrical properties of glass microelectrodes
Schanne, O. F., Lavallée, M., Laprade, R., & Gagné, S. (1968) · Proceedings of the IEEE · doi:10.1109/proc.1968.6459 · Cited by 57
Gingerich, M. D., Hetke, J. F., Anderson, D. J., & Wise, K. D. (2001) · Springer eBooks · doi:10.1007/978-3-642-59497-7_99 · Cited by 57
Self-citationA fully-integrated bandpass amplifier for extracellular neural recording
Olsson, R. H., Gulari, A. N., & Wise, K. D. (2003) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2003.1196783 · Cited by 54
Self-citationA planar IrO multichannel stimulating electrode for use in neural prostheses
Tanghe, S. J., Najafi, K., & Wise, K. D. (1990) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(90)80250-4 · Cited by 47
Self-citationA tantalum-on-sapphire microelectrode array
May, G. A., Shamma, S., & White, R. L. (1979) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1979.19798 · Cited by 41
A biomimetic retinal stimulating array
Weiland, J. D., & Humayun, M. S. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1511496 · Cited by 40
A microprobe with integrated amplifiers for neurophysiology
Wise, K. D., & Angell, J. B. (1971) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.1971.1154991 · Cited by 37
Self-citationA Shuttered Neural Probe With On-Chip Flowmeters for Chronic In Vivo Drug Delivery
Papageorgiou, D. P., Shore, S. E., Bledsoe, S. C., & Wise, K. D. (2006) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.863733 · Cited by 37
Self-citationFlexible miniature ribbon cables for long‐term connection to implantable sensors
Hetke, J. F., Najafi, K., & Wise, K. D. (1990) · Sensors and Actuators A: Physical · doi:10.1016/0924-4247(90)87076-u · Cited by 33 · cited 1×
“Such cables are more robust than silicon alternatives [ 60 ] and potentially solve the mechanical interconnect problems between the electrodes and the electronics package.”
BackgroundSelf-citationA shuttered probe with in-line flowmeters for chronic in-vivo drug delivery
Papageorgiou, D., Bledsoe, S. C., Gulari, M. N., Hetke, J. F., Anderson, D. J., & Wise, K. D. (2002) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2001.906516 · Cited by 33
Self-citationPerlin, G. E., Sodagar, A. M., & Wise, K. D. (2006) · 2006 International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2006.260193 · Cited by 30
Self-citationElectrical Stimulation of Acoustical Nerve and Inferior Colliculus
Simmons, F. B., Mongeon, C. J., Lewis, W. R., & Huntington, D. A. (1964) · Archives of Otolaryngology · doi:10.1001/archotol.79.6.559 · Cited by 29
Neural Probes for Concurrent Detection of Neurochemical and Electrophysiological Signals in vivo
Johnson, M. D., Franklin, R. K., Scott, K., Brown, R. B., & Kipke, D. R. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616203 · Cited by 27
An EEG spike detection algorithm using artificial neural network with multi-channel correlation
Ko, C., Lin, Y., Chung, H., & Jan, G. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1998.747014 · Cited by 27
An Implantable Microsystem for Wireless Multi-Channel Cortical Recording
Sodagar, A. M., Perlin, G. E., Yao, Y., Wise, K. D., & Najafi, K. (2007) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.2007.4300073 · Cited by 27
Self-citationA 32-Site 4-Channel Cochlear Electrode Array
Bhatti, P. T., Lee, S., & Wise, K. D. (2006) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2006.1696036 · Cited by 21
Self-citationThe bi-directional spike detection in EEG using mathematical morphology and wavelet transform
Pon, L.-S., Sun, M., & Sclabassi, R. J. (2003) · doi:10.1109/icosp.2002.1180082 · Cited by 18
A low-profile three-dimensional neural stimulating array with on-chip current generation
Yao, Y., Gulari, M. N., Hetke, J. F., & Wise, K. D. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1403588 · Cited by 16
Self-citationYao, Y., Gulari, M. N., Ghimire, S., Hetke, J. F., & Wise, K. D. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616663 · Cited by 15
Self-citationActive electrodes for EEG and evoked potential
Ko, W. H. (2002) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1998.747053 · Cited by 15
Franklin, B., V (1757) · Philosophical Transactions of the Royal Society of London · doi:10.1098/rstl.1757.0060 · Cited by 14
Sodagar, A. M., Wise, K. D., & Najafi, K. (2006) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2006.4600302 · Cited by 12
Self-citationAction potential detection with automatic template matching
Kim, S., McNames, J., & Burchiel, K. J. (2005) · doi:10.1109/iembs.2004.1403085 · Cited by 12
Perlin, G. E., & Wise, K. D. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1403590 · Cited by 8
Self-citationA computer-assisted spike detecting system using normalized method for epilepsy diagnosis
Oomori, Y., Yano, F., Ninomija, S. P., Kodama, H., Fujino, T., & Wada, J. A. (2003) · Hawaii International Conference on System Sciences (HICSS) · doi:10.1109/hicss.1988.11959 · Cited by 4
Cited by
Microneedles for drug and vaccine delivery
Kim, Y.-C., Park, J.-H., & Prausnitz, M. R. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.04.005 · Cited by 1,760
An Integrated Brain-Machine Interface Platform With Thousands of Channels
Musk, E., & Neuralink (2019) · Journal of Medical Internet Research · doi:10.2196/16194 · Cited by 1,206
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
Metadata
- Authors
- Wise, K. D., Sodagar, A. M., Yao, Y., Gulari, M. N., Perlin, G. E., & Najafi, K.
- Venue
- Proceedings of the IEEE
- Published
- 2008-07
- Volume
- 96
- Issue
- 7
- Pages
- 1184-1202
- ISSN
- 0018-9219 (ISSN-L)
- 1558-2256
- OpenAlex
- W2121570266
- Cited by
- 335
- References
- 77
- FWCI
- 10.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.