The DOI matches its Crossref record; 92 of the 92 references it cites were found in a registry or an index.
Ultrasound Localization Microscopy and Super-Resolution: A State of the Art
Open accessAbstract
Because it drives the compromise between resolution and penetration, the diffraction limit has long represented an unreachable summit to conquer in ultrasound imaging. Within a few years after the introduction of optical localization microscopy, we proposed its acoustic alter ego that exploits the micrometric localization of microbubble contrast agents to reconstruct the finest vessels in the body in-depth. Various groups now working on the subject are optimizing the localization precision, microbubble separation, acquisition time, tracking, and velocimetry to improve the capacity of ultrasound localization microscopy (ULM) to detect and distinguish vessels much smaller than the wavelength. It has since been used in vivo in the brain, the kidney, and tumors. In the clinic, ULM is bound to improve drastically our vision of the microvasculature, which could revolutionize the diagnosis of cancer, arteriosclerosis, stroke, and diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Hungarian method for the assignment problem
Kuhn, H. W. (1955) · Naval Research Logistics Quarterly · doi:10.1002/nav.3800020109 · Cited by 13,120
Negative Refraction Makes a Perfect Lens
Pendry, J. B. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.3966 · Cited by 12,159
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Green fluorescent protein as a marker for gene expression
Chalfie, M., Tu, Y., Euskirchen, G., Ward, W. W., & Prasher, D. C. (1994) · Science · doi:10.1126/science.8303295 · Cited by 6,802
Hell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065
Algorithms for the Assignment and Transportation Problems
Munkres, J. (1957) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0105003 · Cited by 3,986
Gustafsson, M. G. L. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00710.x · Cited by 3,786
Ultra-High Resolution Imaging by Fluorescence Photoactivation Localization Microscopy
Hess, S. T., Girirajan, T. P. K., & Mason, M. D. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.091116 · Cited by 3,605
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
Leighton, T. G. (2012) · Cited by 2,284
Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography
Montaldo, G., Tanter, M., Bercoff, J., Benech, N., & Fink, M. (2009) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1067 · Cited by 1,814
Self-citationNear-Field Optics: Microscopy, Spectroscopy, and Surface Modification Beyond the Diffraction Limit
Betzig, E., & Trautman, J. K. (1992) · Science · doi:10.1126/science.257.5067.189 · Cited by 1,808
Wei, K., Jayaweera, A. R., Firoozan, S., Linka, A., Skyba, D. M., & Kaul, S. (1998) · Circulation · doi:10.1161/01.cir.97.5.473 · Cited by 1,616
Ultrafast ultrasound localization microscopy for deep super-resolution vascular imaging
Errico, C., Pierre, J., Pezet, S., Desailly, Y., Lenkei, Z., Couture, O., & Tanter, M. (2015) · Nature · doi:10.1038/nature16066 · Cited by 1,349
Self-citationOptical detection and spectroscopy of single molecules in a solid
Moerner, W. E., & Kador, L. (1989) · Physical Review Letters · doi:10.1103/physrevlett.62.2535 · Cited by 1,271
Single Molecules Observed by Near-Field Scanning Optical Microscopy
Betzig, E., & Chichester, R. J. (1993) · Science · doi:10.1126/science.262.5138.1422 · Cited by 1,262
High-density mapping of single-molecule trajectories with photoactivated localization microscopy
Manley, S., Gillette, J. M., Patterson, G. H., Shroff, H., Hess, H. F., Betzig, E., & Lippincott-Schwartz, J. (2008) · Nature Methods · doi:10.1038/nmeth.1176 · Cited by 1,199
Breaking the Diffraction Barrier: Super-Resolution Imaging of Cells
Huang, B., Babcock, H., & Zhuang, X. (2010) · Cell · doi:10.1016/j.cell.2010.12.002 · Cited by 1,156
Ultrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2014.2882 · Cited by 1,151
Self-citationFast, background-free, 3D super-resolution optical fluctuation imaging (SOFI)
Dertinger, T., Colyer, R., Iyer, G., Weiss, S., & Enderlein, J. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0907866106 · Cited by 1,130
Demene, C., Deffieux, T., Pernot, M., Osmanski, B.-F., Biran, V., Gennisson, J.-L., Sieu, L.-A., Bergel, A., Franqui, S., Correas, J.-M., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2428634 · Cited by 983
Self-citationInterferometric fluorescent super-resolution microscopy resolves 3D cellular ultrastructure
Shtengel, G., Galbraith, J. A., Galbraith, C. G., Lippincott-Schwartz, J., Gillette, J. M., Manley, S., Sougrat, R., Waterman, C. M., Kanchanawong, P., Davidson, M. W., et al. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0813131106 · Cited by 888
Live-cell photoactivated localization microscopy of nanoscale adhesion dynamics
Shroff, H., Galbraith, C. G., Galbraith, J. A., & Betzig, E. (2008) · Nature Methods · doi:10.1038/nmeth.1202 · Cited by 873
Fluorescence assay in biology and medicine
Udenfriend, S. (1962) · Medical Entomology and Zoology · Cited by 772
Functional ultrasound imaging of the brain
Macé, E., Montaldo, G., Cohen, I., Baulac, M., Fink, M., & Tanter, M. (2011) · Nature Methods · doi:10.1038/nmeth.1641 · Cited by 751
Self-citationTanter, M., Bercoff, J., Athanasiou, A., Deffieux, T., Gennisson, J.-L., Montaldo, G., Muller, M., Tardivon, A., & Fink, M. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.02.002 · Cited by 733
Self-citationFocusing Beyond the Diffraction Limit with Far-Field Time Reversal
Lerosey, G., de Rosny, J., Tourin, A., & Fink, M. (2007) · Science · doi:10.1126/science.1134824 · Cited by 694
Hyperlenses and metalenses for far-field super-resolution imaging
Lu, D., & Liu, Z. (2012) · Nature Communications · doi:10.1038/ncomms2176 · Cited by 598
Ultrafast compound doppler imaging: providing full blood flow characterization
Bercoff, J., Montaldo, G., Loupas, T., Savery, D., Mézière, F., Fink, M., & Tanter, M. (2011) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2011.1780 · Cited by 510
Self-citationPrecisely and accurately localizing single emitters in fluorescence microscopy
Deschout, H., Zanacchi, F. C., Mlodzianoski, M., Diaspro, A., Bewersdorf, J., Hess, S. T., & Braeckmans, K. (2014) · Nature Methods · doi:10.1038/nmeth.2843 · Cited by 498
von Diezmann, L., Shechtman, Y., & Moerner, W. E. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00629 · Cited by 491
A fundamental limit on delay estimation using partially correlated speckle signals
Walker, W. F., & Trahey, G. E. (1995) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.365243 · Cited by 479
In Vivo Acoustic Super-Resolution and Super-Resolved Velocity Mapping Using Microbubbles
Christensen-Jeffries, K. M., Browning, R. J., Tang, M., Dunsby, C. W., & Eckersley, R. J. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2359650 · Cited by 465
Leighton, T. G., & Apfel, R. E. (1994) · The Journal of the Acoustical Society of America · doi:10.1121/1.410082 · Cited by 427
Bavu, É., Gennisson, J.-L., Couade, M., Bercoff, J., Mallet, V., Fink, M., Badel, A., Vallet-Pichard, A., Nalpas, B., Tanter, M., et al. (2011) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2011.05.016 · Cited by 415
Self-citationUltrafast compound imaging for 2-D motion vector estimation: application to transient elastography
Tanter, M., Bercoff, J., Sandrin, L., & Fink, M. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2002.1041078 · Cited by 414
Self-citationQuickPALM: 3D real-time photoactivation nanoscopy image processing in ImageJ
Henriques, R., Lelek, M., Fornasiero, E. F., Valtorta, F., Zimmer, C., & Mhlanga, M. M. (2010) · Nature Methods · doi:10.1038/nmeth0510-339 · Cited by 411
Acoustic reporter genes for noninvasive imaging of microorganisms in mammalian hosts
Bourdeau, R. W., Lee-Gosselin, A., Lakshmanan, A., Farhadi, A., Kumar, S. R., Nety, S. P., & Shapiro, M. G. (2018) · Nature · doi:10.1038/nature25021 · Cited by 396
Doppler Ultrasound: Physics, Instrumentation and Signal Processing
Evans, D. H. (2000) · Cited by 364
3D ultrafast ultrasound imaging in vivo
Provost, J., Papadacci, C., Arango, J. E., Imbault, M., Fink, M., Gennisson, J.-L., Tanter, M., & Pernot, M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/19/l1 · Cited by 356
Self-citationSheeran, P. S., Luois, S., Dayton, P. A., & Matsunaga, T. O. (2011) · Langmuir · doi:10.1021/la2013705 · Cited by 309
Opacic, T., Dencks, S., Theek, B., Piepenbrock, M., Ackermann, D., Rix, A., Lammers, T., Stickeler, E., Delorme, S., Schmitz, G., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-03973-8 · Cited by 295
McDannold, N., Vykhodtseva, N., & Hynynen, K. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.10.016 · Cited by 288
Beyond 30 MHz [applications of high-frequency ultrasound imaging]
Lockwood, G. R., Turnball, D. H., Christopher, D. A., & Foster, F. S. (1996) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.544513 · Cited by 286
Song, P., Trzasko, J. D., Manduca, A., Huang, R., Kadirvel, R., Kallmes, D. F., & Chen, S. (2018) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2017.2778941 · Cited by 285
Acoustic super-resolution with ultrasound and microbubbles
Viessmann, O. M., Eckersley, R. J., Christensen-Jeffries, K., Tang, M. X., & Dunsby, C. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/18/6447 · Cited by 277
ULA-OP: an advanced open platform for ultrasound research
Tortoli, P., Bassi, L., Boni, E., Dallai, A., Guidi, F., & Ricci, S. (2009) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1303 · Cited by 273
Time-Resolved Pulsed Elastography with Ultrafast Ultrasonic Imaging
Sandrin, L., Catheline, S., Tanter, M., Hennequin, X., & Fink, M. (1999) · Ultrasonic Imaging · doi:10.1177/016173469902100402 · Cited by 267
Self-citationLin, F., Shelton, S. E., Espíndola, D., Rojas, J. D., Pinton, G., & Dayton, P. A. (2017) · Theranostics · doi:10.7150/thno.16899 · Cited by 260
A super‐resolution ultrasound method for brain vascular mapping
OˈReilly, M. A., & Hynynen, K. (2013) · Medical Physics · doi:10.1118/1.4823762 · Cited by 242
Focusing of therapeutic ultrasound through a human skull: A numerical study
Sun, J., & Hynynen, K. (1998) · The Journal of the Acoustical Society of America · doi:10.1121/1.424383 · Cited by 213
Functional ultrasound imaging of brain activity in human newborns
Demene, C., Baranger, J., Bernal, M., Delanoe, C., Auvin, S., Biran, V., Alison, M., Mairesse, J., Harribaud, E., Pernot, M., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aah6756 · Cited by 207
Self-citationKlibanov, A. L., Rasche, P. T., Hughes, M. S., Wojdyla, J. K., Galen, K. P., Wible, J. H., & Brandenburger, G. H. (2004) · Investigative Radiology · doi:10.1097/01.rli.0000115926.96796.75 · Cited by 199
Newman, P. G., & Rozycki, G. S. (1998) · Surgical Clinics of North America · doi:10.1016/s0039-6109(05)70308-x · Cited by 199
Functional ultrasound neuroimaging: a review of the preclinical and clinical state of the art
Deffieux, T., Demene, C., Pernot, M., & Tanter, M. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.02.001 · Cited by 195
Self-citationA New 15–50 MHz Array-Based Micro-Ultrasound Scanner for Preclinical Imaging
Foster, F. S., Mehi, J., Lukacs, M., Hirson, D., White, C., Chaggares, C., & Needles, A. (2009) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2009.04.012 · Cited by 193
Ultrasound contrast plane wave imaging
Couture, O., Fink, M., & Tanter, M. (2012) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2508 · Cited by 190
Self-citationSono-activated ultrasound localization microscopy
Desailly, Y., Couture, O., Fink, M., & Tanter, M. (2013) · Applied Physics Letters · doi:10.1063/1.4826597 · Cited by 187
Self-citationReal-time imaging of brain activity in freely moving rats using functional ultrasound
Urban, A., Dussaux, C., Martel, G., Brunner, C., Macé, É., & Montaldo, G. (2015) · Nature Methods · doi:10.1038/nmeth.3482 · Cited by 185
Blood flow distributions by microsphere deposition methods
Prinzen, F. (2000) · Cardiovascular Research · doi:10.1016/s0008-6363(99)00252-7 · Cited by 182
Detection and Tracking of Multiple Microbubbles in Ultrasound B-Mode Images
Ackermann, D., & Schmitz, G. (2016) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2015.2500266 · Cited by 172
Ultrasound localization microscopy to image and assess microvasculature in a rat kidney
Foiret, J., Zhang, H., Ilovitsh, T., Mahakian, L., Tam, S., & Ferrara, K. W. (2017) · Scientific Reports · doi:10.1038/s41598-017-13676-7 · Cited by 169
Microbubble ultrasound super-localization imaging (MUSLI)
Couture, O., Besson, B., Montaldo, G., Fink, M., & Tanter, M. (2011) · 2011 IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2011.6293576 · Cited by 164
Self-citationEEG and functional ultrasound imaging in mobile rats
Sieu, L.-A., Bergel, A., Tiran, E., Deffieux, T., Pernot, M., Gennisson, J.-L., Tanter, M., & Cohen, I. (2015) · Nature Methods · doi:10.1038/nmeth.3506 · Cited by 158
Self-citationMöckl, L., Lamb, D. C., & Bräuchle, C. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201410265 · Cited by 157
Intraoperative Functional Ultrasound Imaging of Human Brain Activity
Imbault, M., Chauvet, D., Gennisson, J., Capelle, L., & Tanter, M. (2017) · Scientific Reports · doi:10.1038/s41598-017-06474-8 · Cited by 152
Self-citationSuperresolution Imaging of Biological Systems Using Photoactivated Localization Microscopy
Sengupta, P., van Engelenburg, S. B., & Lippincott‐Schwartz, J. (2014) · Chemical Reviews · doi:10.1021/cr400614m · Cited by 150
Comparison between SOFI and STORM
Geissbuehler, S., Dellagiacoma, C., & Lasser, T. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.000408 · Cited by 147
Errico, C., Osmanski, B.-F., Pezet, S., Couture, O., Lenkei, Z., & Tanter, M. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.09.037 · Cited by 145
Self-citationMyocardial Contrast Echocardiography
Lepper, W., Belcik, T. A., Wei, K. S., et al. (2004) · Circulation · doi:10.1161/01.cir.0000132613.53542.e9 · Cited by 140
4D microvascular imaging based on ultrafast Doppler tomography
Demené, C., Tiran, E., Sieu, L.-A., Bergel, A., Gennisson, J. L., Pernot, M., Deffieux, T., Cohen, I., & Tanter, M. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.11.014 · Cited by 139
Self-citationSubwavelength motion-correction for ultrafast ultrasound localization microscopy
Hingot, V., Errico, C., Tanter, M., & Couture, O. (2017) · Ultrasonics · doi:10.1016/j.ultras.2017.01.008 · Cited by 135
Self-citationFast Vascular Ultrasound Imaging With Enhanced Spatial Resolution and Background Rejection
Bar‐Zion, A., Tremblay‐Darveau, C., Solomon, O., Adam, D., & Eldar, Y. C. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2600372 · Cited by 123
Multiwave imaging and super resolution
Fink, M., & Tanter, M. (2010) · Physics Today · doi:10.1063/1.3326986 · Cited by 119
Self-citationSuper-Resolution Ultrasound Imaging in Vivo with Transient Laser-Activated Nanodroplets
Luke, G. P., Hannah, A. S., & Emelianov, S. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b00108 · Cited by 119
Quantification of Microvascular Tortuosity during Tumor Evolution Using Acoustic Angiography
Shelton, S. E., Lee, Y. Z., Lee, M., Chérin, E., Foster, F. S., Aylward, S., & Dayton, P. A. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.02.012 · Cited by 116
Sonoporation: Concept and Mechanisms
Bouakaz, A., Zeghimi, A., & Doinikov, A. A. (2015) · Advances in experimental medicine and biology · doi:10.1007/978-3-319-22536-4_10 · Cited by 113
Ultrafast Doppler Reveals the Mapping of Cerebral Vascular Resistivity in Neonates
Demené, C., Pernot, M., Biran, V., Alison, M., Fink, M., Baud, O., & Tanter, M. (2014) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2014.49 · Cited by 109
Self-citationImaging tumor vascularity by tracing single microbubbles
Siepmann, M., Schmitz, G., Bzyl, J., Palmowski, M., & Kiessling, F. M. (2011) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2011.0476 · Cited by 101
Microbubble Axial Localization Errors in Ultrasound Super-Resolution Imaging
Christensen-Jeffries, K. M., Harput, S., Brown, J., Wells, P. N. T., Aljabar, P., Dunsby, C. W., Tang, M., & Eckersley, R. J. (2017) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2017.2741067 · Cited by 94
Contrast enhanced ultrasound by real-time spatiotemporal filtering of ultrafast images
Desailly, Y., Tissier, A.-M., Corréas, J.-M., Wintzenrieth, F., Tanter, M., & Couture, O. (2016) · Physics in Medicine and Biology · doi:10.1088/1361-6560/62/1/31 · Cited by 81
Self-citationCharacterization of Contrast Agent Microbubbles for Ultrasound Imaging and Therapy Research
Mulvana, H., Browning, R. J., Luan, Y., de Jong, N., Tang, M., Eckersley, R. J., & Stride, E. (2016) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2016.2613991 · Cited by 72
In vivo ultrasound biomicroscopy in developmental biology
Turnbull, D. H., & Foster, F. S. (2002) · Trends in biotechnology · doi:10.1016/s0167-7799(02)02003-6 · Cited by 62
Ghosh, D., Xiong, F., Sirsi, S. R., Shaul, P. W., Mattrey, R. F., & Hoyt, K. (2017) · Medical Physics · doi:10.1002/mp.12606 · Cited by 52
Lin, F., Tsuruta, J. K., Rojas, J. D., & Dayton, P. A. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.05.014 · Cited by 49
Dynamic Imaging of Colloidal-Crystal Nanostructures at 200 Frames per Second
Lauterbach, M. A., Ullal, C. K., Westphal, V., & Hell, S. W. (2010) · Langmuir · doi:10.1021/la102474p · Cited by 33
Acoustic particle palpation for measuring tissue elasticity
Körük, H., Ghamrawy, A. E., Pouliopoulos, A. N., & Choi, J. J. (2015) · Applied Physics Letters · doi:10.1063/1.4936345 · Cited by 30
Sparsity-driven super-localization in clinical contrast-enhanced ultrasound
van Sloun, R. J. G., Solomon, O., Eldar, Y. C., Wijkstra, H., & Mischi, M. (2017) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2017.8092875 · Cited by 17
Dencks, S., Opacic, T., Piepenbrock, M., Kiessling, F., & Georg, S. (2017) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2017.8092020 · Cited by 17
Subwavelength far-field ultrasound drug-delivery
Hingot, V., Bézagu, M., Errico, C., Desailly, Y., Bocheux, R., Tanter, M., & Couture, O. (2016) · Applied Physics Letters · doi:10.1063/1.4967009 · Cited by 15
Self-citationGhosh, D., Peng, J., Sirsi, S. R., Mineo, C., Mattrey, R. F., Shaul, P. W., & Hoyt, K. (2017) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2017.8092192 · Cited by 13
Cited by
Super-resolution Ultrasound Imaging
Christensen-Jeffries, K., Couture, O., Dayton, P. A., Eldar, Y. C., Hynynen, K., Kiessling, F., O'Reilly, M., Pinton, G. F., Schmitz, G., Tang, M.-X., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.11.013 · Cited by 558
Self-citationTranscranial ultrafast ultrasound localization microscopy of brain vasculature in patients
Demené, C., Robin, J., Dizeux, A., Heiles, B., Pernot, M., Tanter, M., & Perren, F. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00697-x · Cited by 370
Self-citationDeep learning in ultrasound imaging
van Sloun, R. J. G., Cohen, R., & Eldar, Y. C. (2020) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2932116 · Cited by 316
de Maar, J. S., Sofias, A. M., Porta Siegel, T., Vreeken, R. J., Moonen, C., Bos, C., & Deckers, R. (2020) · Theranostics · doi:10.7150/thno.38625 · Cited by 71
Metadata
- Authors
- Couture, O., Hingot, V., Heiles, B., Muleki-Seya, P., & Tanter, M.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Published
- 2018-08
- Volume
- 65
- Issue
- 8
- Pages
- 1304-1320
- ISSN
- 0885-3010 (ISSN-L)
- 1525-8955
- OpenAlex
- W2809883623
- Cited by
- 423
- References
- 92
- FWCI
- 10.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.