The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
In Vivo Endoscopic Optical Biopsy with Optical Coherence Tomography
Abstract
Current medical imaging technologies allow visualization of tissue anatomy in the human body at resolutions ranging from 100 micrometers to 1 millimeter. These technologies are generally not sensitive enough to detect early-stage tissue abnormalities associated with diseases such as cancer and atherosclerosis, which require micrometer-scale resolution. Here, optical coherence tomography was adapted to allow high-speed visualization of tissue in a living animal with a catheter-endoscope 1 millimeter in diameter. This method, referred to as “optical biopsy,” was used to obtain cross-sectional images of the rabbit gastrointestinal and respiratory tracts at 10-micrometer resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Self-citationOptical Coherence Tomography of the Human Retina
Hee, M. R. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100030081025 · Cited by 1,634
Imaging of Macular Diseases with Optical Coherence Tomography
Puliafito, C. A., Hee, M. R., Lin, C. P., Reichel, E., Schuman, J. S., Duker, J. S., Izatt, J. A., Swanson, E. A., & Fujimoto, J. G. (1995) · Ophthalmology · doi:10.1016/s0161-6420(95)31032-9 · Cited by 1,267
Self-citationIn vivo retinal imaging by optical coherence tomography
Swanson, E. A., Izatt, J. A., Lin, C. P., Fujimoto, J. G., Schuman, J. S., Hee, M. R., Huang, D., & Puliafito, C. A. (1993) · Optics Letters · doi:10.1364/ol.18.001864 · Cited by 918
Self-citationOptical biopsy and imaging using optical coherence tomography
Fujimoto, J. G., Brezinski, M. E., Tearney, G. J., Boppart, S. A., Bouma, B., Hee, M. R., Southern, J. F., & Swanson, E. A. (1995) · Nature Medicine · doi:10.1038/nm0995-970 · Cited by 887
Self-citationOptical Coherence Tomography for Optical Biopsy: Properties and Demonstration of Vascular Pathology
Brezinski, M. E., Tearney, G. J., Bouma, B. E., Izatt, J. A., Hee, M. R., Swanson, E. A., Southern, J. F., & Fujimoto, J. G. (1996) · Circulation · doi:10.1161/01.cir.93.6.1206 · Cited by 566
Self-citationIn Vivo Optical Coherence Tomography
Fercher, A. F., Hitzenberger, C. K., Drexler, W., Kamp, G., & Sattmann, H. (1993) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)71762-3 · Cited by 467
Subsurface Imaging of Living Skin with Optical Coherence Microscopy
Schmitt, J. M., Yadlowsky, M. J., & Bonner, R. F. (1995) · Dermatology · doi:10.1159/000246523 · Cited by 251
Cited by
Imaging and Photodynamic Therapy: Mechanisms, Monitoring, and Optimization
Celli, J. P., Spring, B. Q., Rizvi, I., Evans, C. L., Samkoe, K. S., Verma, S., Pogue, B. W., & Hasan, T. (2010) · Chemical Reviews · doi:10.1021/cr900300p · Cited by 2,324
Femtosecond pulse shaping using spatial light modulators
Weiner, A. M. (2000) · Review of Scientific Instruments · doi:10.1063/1.1150614 · Cited by 2,297
Shedding light onto live molecular targets
Weissleder, R., & Ntziachristos, V. (2003) · Nature Medicine · doi:10.1038/nm0103-123 · Cited by 1,909
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Immunotargeted Nanoshells for Integrated Cancer Imaging and Therapy
Loo, C., Lowery, A., Halas, N., West, J., & Drezek, R. (2005) · Nano Letters · doi:10.1021/nl050127s · Cited by 1,792
In vivo imaging of tumors with protease-activated near-infrared fluorescent probes
Weissleder, R., Tung, C.-H., Mahmood, U., & Bogdanov, A. (1999) · Nature Biotechnology · doi:10.1038/7933 · Cited by 1,591
Weissleder, R., & Mahmood, U. (2001) · Radiology · doi:10.1148/radiology.219.2.r01ma19316 · Cited by 1,315
Characterization of Human Atherosclerosis by Optical Coherence Tomography
Yabushita, H., Bouma, B. E., Houser, S. L., Aretz, H. T., Jang, I.-K., Schlendorf, K. H., Kauffman, C. R., Shishkov, M., Kang, D.-H., Halpern, E. F., et al. (2002) · Circulation · doi:10.1161/01.cir.0000029927.92825.f6 · Cited by 1,246
Self-citationAu nanoparticles target cancer
Jain, P. K., El-Sayed, I. H., & El-Sayed, M. A. (2007) · Nano Today · doi:10.1016/s1748-0132(07)70016-6 · Cited by 1,157
Optical Coherence Tomography: An Emerging Technology for Biomedical Imaging and Optical Biopsy
Fujimoto, J. G., Pitris, C., Boppart, S. A., & Brezinski, M. E. (2000) · Neoplasia · doi:10.1038/sj.neo.7900071 · Cited by 1,138
Self-citationOptical coherence tomography for ultrahigh resolution in vivo imaging
Fujimoto, J. G. (2003) · Nature Biotechnology · doi:10.1038/nbt892 · Cited by 1,033
Self-citationUltrahigh-resolution ophthalmic optical coherence tomography
Drexler, W., Morgner, U., Ghanta, R. K., Kärtner, F. X., Schuman, J. S., & Fujimoto, J. G. (2001) · Nature Medicine · doi:10.1038/86589 · Cited by 962
Self-citationHigh-speed optical frequency-domain imaging
Yun, S., Tearney, G., de Boer, J., Iftimia, N., & Bouma, B. (2003) · Optics Express · doi:10.1364/oe.11.002953 · Cited by 865
Self-citationSharma, P., Brown, S., Walter, G., Santra, S., & Moudgil, B. (2006) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2006.05.026 · Cited by 755
Advances in ultrasound biomicroscopy
Foster, F. S., Pavlin, C. J., Harasiewicz, K. A., Christopher, D. A., & Turnbull, D. H. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00096-4 · Cited by 719
AI in Medical Imaging Informatics: Current Challenges and Future Directions
Panayides, A. S., Amini, A., Filipovic, N. D., Sharma, A., Tsaftaris, S. A., Young, A., Foran, D., Do, N., Golemati, S., Kurc, T., et al. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.2991043 · Cited by 713
Quantification of Macrophage Content in Atherosclerotic Plaques by Optical Coherence Tomography
Tearney, G. J., Yabushita, H., Houser, S. L., Aretz, H. T., Jang, I.-K., Schlendorf, K. H., Kauffman, C. R., Shishkov, M., Halpern, E. F., & Bouma, B. E. (2003) · Circulation · doi:10.1161/01.cir.0000044384.41037.43 · Cited by 704
Self-citationMourant, J. R., Freyer, J. P., Hielscher, A. H., Eick, A. A., Shen, D., & Johnson, T. M. (1998) · Applied Optics · doi:10.1364/ao.37.003586 · Cited by 681
Three-dimensional Retinal Imaging with High-Speed Ultrahigh-Resolution Optical Coherence Tomography
Wojtkowski, M., Srinivasan, V., Fujimoto, J. G., Ko, T., Schuman, J. S., Kowalczyk, A., & Duker, J. S. (2005) · Ophthalmology · doi:10.1016/j.ophtha.2005.05.023 · Cited by 640
Self-citationTheory, developments and applications of optical coherence tomography
Tomlins, P. H., & Wang, R. K. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/002 · Cited by 631
Three dimensional optical angiography
Wang, R. K., Jacques, S. L., Ma, Z., Hurst, S., Hanson, S. R., & Gruber, A. (2007) · Optics Express · doi:10.1364/oe.15.004083 · Cited by 627
Scanner-Free and Wide-Field Endoscopic Imaging by Using a Single Multimode Optical Fiber
Choi, Y., Yoon, C., Kim, M., Yang, T. D., Fang-Yen, C., Dasari, R. R., Lee, K. J., & Choi, W. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.203901 · Cited by 619
High-resolution full-field optical coherence tomography with a Linnik microscope
Dubois, A., Vabre, L., Boccara, A.-C., & Beaurepaire, E. (2002) · Applied Optics · doi:10.1364/ao.41.000805 · Cited by 567
Optical coherence tomography: a review of clinical development from bench to bedside
Zysk, A. M., Nguyen, F. T., Oldenburg, A. L., Marks, D. L., & Boppart, S. A. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2793736 · Cited by 547
Self-citationClinical Imaging of the High-Risk or Vulnerable Atherosclerotic Plaque
Fayad, Z. A., & Fuster, V. (2001) · Circulation Research · doi:10.1161/hh1601.095596 · Cited by 518
Whole-body optical imaging of green fluorescent protein-expressing tumors and metastases
Yang, M., Baranov, E., Jiang, P., Sun, F.-X., Li, X.-M., Li, L., Hasegawa, S., Bouvet, M., Al-Tuwaijri, M., Chishima, T., et al. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.3.1206 · Cited by 514
Full-field optical coherence microscopy
Beaurepaire, E., Boccara, A. C., Lebec, M., Blanchot, L., & Saint-Jalmes, H. (1998) · Optics Letters · doi:10.1364/ol.23.000244 · Cited by 433
Optical coherence tomography in coronary atherosclerosis assessment and intervention
Araki, M., Park, S.-J., Dauerman, H. L., Uemura, S., Kim, J.-S., Di Mario, C., Johnson, T. W., Guagliumi, G., Kastrati, A., Joner, M., et al. (2022) · Nature Reviews Cardiology · doi:10.1038/s41569-022-00687-9 · Cited by 430
Self-citationSimultaneous functional photoacoustic and ultrasonic endoscopy of internal organs in vivo
Yang, J.-M., Favazza, C., Chen, R., Yao, J., Cai, X., Maslov, K., Zhou, Q., Shung, K. K., & Wang, L. V. (2012) · Nature Medicine · doi:10.1038/nm.2823 · Cited by 429
In vivo video rate optical coherence tomography
Rollins, A. M., Kulkarni, M. D., Yazdanfar, S., Ung-arunyawee, R., & Izatt, J. A. (1998) · Optics Express · doi:10.1364/oe.3.000219 · Cited by 414
Nano-optic endoscope for high-resolution optical coherence tomography in vivo
Pahlevaninezhad, H., Khorasaninejad, M., Huang, Y.-W., Shi, Z., Hariri, L. P., Adams, D. C., Ding, V., Zhu, A., Qiu, C.-W., Capasso, F., et al. (2018) · Nature Photonics · doi:10.1038/s41566-018-0224-2 · Cited by 412
Optical scattering properties of soft tissue: a discrete particle model
Schmitt, J. M., & Kumar, G. (1998) · Applied Optics · doi:10.1364/ao.37.002788 · Cited by 408
Frontiers in Ultrashort Pulse Generation: Pushing the Limits in Linear and Nonlinear Optics
Steinmeyer, G., Sutter, D. H., Gallmann, L., Matuschek, N., & Keller, U. (1999) · Science · doi:10.1126/science.286.5444.1507 · Cited by 397
Biomedical Applications of Plasmon Resonant Metal Nanoparticles
Liao, H., Nehl, C. L., & Hafner, J. H. (2006) · Nanomedicine · doi:10.2217/17435889.1.2.201 · Cited by 396
Inorganic Nanoparticles in Cancer Therapy
Bhattacharyya, S., Kudgus, R. A., Bhattacharya, R., & Mukherjee, P. (2011) · Pharmaceutical Research · doi:10.1007/s11095-010-0318-0 · Cited by 395
Ultrahigh-resolution full-field optical coherence tomography
Dubois, A., Grieve, K., Moneron, G., Lecaque, R., Vabre, L., & Boccara, C. (2004) · Applied Optics · doi:10.1364/ao.43.002874 · Cited by 394
Optical imaging techniques for point-of-care diagnostics
Zhu, H., Isikman, S. O., Mudanyali, O., Greenbaum, A., & Ozcan, A. (2013) · Lab Chip · doi:10.1039/c2lc40864c · Cited by 364
PODOLEANU, A. G. (2012) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03619.x · Cited by 348
Huang, Y.-P., Zheng, Y.-P., Wang, S.-Z., Chen, Z.-P., Huang, Q.-H., & He, Y.-H. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/1/015805 · Cited by 312
Gold nanoshell bioconjugates for molecular imaging in living cells
Loo, C., Hirsch, L., Lee, M.-H., Chang, E., West, J., Halas, N., & Drezek, R. (2005) · Optics Letters · doi:10.1364/ol.30.001012 · Cited by 305
Near-Infrared Optical Imaging of Protease Activity for Tumor Detection
Mahmood, U., Tung, C.-H., Bogdanov, A., & Weissleder, R. (1999) · Radiology · doi:10.1148/radiology.213.3.r99dc14866 · Cited by 301
Applications of optical coherence tomography in dermatology
GAMBICHLER, T., MOUSSA, G., SAND, M., SAND, D., ALTMEYER, P., & HOFFMANN, K. (2005) · Journal of Dermatological Science · doi:10.1016/j.jdermsci.2005.07.006 · Cited by 283
Optical pulse shaping approaches to coherent control
Goswami, D. (2003) · Physics Reports · doi:10.1016/s0370-1573(02)00480-5 · Cited by 280
High resolution in vivo intra-arterial imaging with optical coherence tomography
Fujimoto, J. G., Boppart, S. A., Tearney, G. J., Bouma, B. E., Pitris, C., & Brezinski, M. E. (1999) · Heart · doi:10.1136/hrt.82.2.128 · Cited by 276
Self-citationIngestible electronics for diagnostics and therapy
Steiger, C., Abramson, A., Nadeau, P., Chandrakasan, A. P., Langer, R., & Traverso, G. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0070-3 · Cited by 274
In vivo cellular optical coherence tomography imaging
Boppart, S. A., Bouma, B. E., Pitris, C., Southern, J. F., Brezinski, M. E., & Fujimoto, J. G. (1998) · Nature Medicine · doi:10.1038/nm0798-861 · Cited by 268
Self-citationInteractions of Organic Nitroso Compounds with Metals
Lee, J., Chen, L., West, A. H., & Richter-Addo, G. B. (2002) · Chemical Reviews · doi:10.1021/cr0000731 · Cited by 267
Optical coherence tomography – development, principles, applications
Fercher, A. F. (2010) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2009.11.002 · Cited by 259
Park, B. H., Saxer, C., Srinivas, S. M., Nelson, J. S., & de Boer, J. F. (2001) · Journal of Biomedical Optics · doi:10.1117/1.1413208 · Cited by 256
In vivo imaging of lymph node metastasis with telomerase-specific replication-selective adenovirus
Kishimoto, H., Kojima, T., Watanabe, Y., Kagawa, S., Fujiwara, T., Uno, F., Teraishi, F., Kyo, S., Mizuguchi, H., Hashimoto, Y., et al. (2006) · Nature Medicine · doi:10.1038/nm1404 · Cited by 179
Umeoka, T., Kawashima, T., Kagawa, S., Teraishi, F., Taki, M., Nishizaki, M., Kyo, S., Nagai, K., Urata, Y., Tanaka, N., et al. (2004) · Cancer Research · doi:10.1158/0008-5472.can-04-1335 · Cited by 72
“Improvements in methods of external imaging such as computed tomography, magnetic resonance imaging, and ultrasound techniques have increased the sensitivity for visualizing tumors and metastases (1, 2); a limiting factor in structural and anatomical imaging, however, is the inability to specifically identify malignan…”
MethodSystems Neuroengineering: Understanding and Interacting with the Brain
Edelman, B. J., Johnson, N., Sohrabpour, A., Tong, S., Thakor, N., & He, B. (2015) · Engineering · doi:10.15302/j-eng-2015078 · Cited by 45
“OCT provides non-contact crosssectional tissue imaging with micron spatial resolution and in real time, providing images of three-dimensional tissue microstructures at a penetration depth of 2 mm [7].”
Background
Metadata
- Authors
- Tearney, G. J., Brezinski, M. E., Bouma, B. E., Boppart, S. A., Pitris, C., Southern, J. F., & Fujimoto, J. G.
- Venue
- Science
- Published
- 1997-06-27
- Volume
- 276
- Issue
- 5321
- Pages
- 2037-2039
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2036163000
- Cited by
- 1,364
- References
- 8
- FWCI
- 47.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.