Current and Developing Technologies for Monitoring Agents of Bioterrorism and Biowarfare
Open accessThe DOI matches its Crossref record; 150 of the 150 references it cites were found in a registry or an index.
Abstract
SUMMARY: Recent events have made public health officials acutely aware of the importance of rapidly and accurately detecting acts of bioterrorism. Because bioterrorism is difficult to predict or prevent, reliable platforms to rapidly detect and identify biothreat agents are important to minimize the spread of these agents and to protect the public health. These platforms must not only be sensitive and specific, but must also be able to accurately detect a variety of pathogens, including modified or previously uncharacterized agents, directly from complex sample matrices. Various commercial tests utilizing biochemical, immunological, nucleic acid, and bioluminescence procedures are currently available to identify biological threat agents. Newer tests have also been developed to identify such agents using aptamers, biochips, evanescent wave biosensors, cantilevers, living cells, and other innovative technologies. This review describes these current and developing technologies and considers challenges to rapid, accurate detection of biothreat agents. Although there is no ideal platform, many of these technologies have proved invaluable for the detection and identification of biothreat agents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Official Methods of Analysis of
(1980) · Analytical Chemistry · doi:10.1021/ac50052a726 · Cited by 59,330
Manual of Clinical Microbiology.
(1980) · Annals of Internal Medicine · doi:10.7326/0003-4819-93-6-939_2 · Cited by 14,411
Loop-mediated isothermal amplification of DNA
Notomi, T. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.12.e63 · Cited by 8,805
Heid, C. A., Stevens, J., Livak, K. J., & Williams, P. M. (1996) · Genome Research · doi:10.1101/gr.6.10.986 · Cited by 6,174
Molecular Beacons: Probes that Fluoresce upon Hybridization
Tyagi, S., & Kramer, F. R. (1996) · Nature Biotechnology · doi:10.1038/nbt0396-303 · Cited by 4,155
Nanoparticles with Raman Spectroscopic Fingerprints for DNA and RNA Detection
Cao, Y. C., Jin, R., & Mirkin, C. A. (2002) · Science · doi:10.1126/science.297.5586.1536 · Cited by 2,971
Holland, P. M., Abramson, R. D., Watson, R., & Gelfand, D. H. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.16.7276 · Cited by 2,693
Luminescent quantum dots for multiplexed biological detection and imaging
Chan, W. C. W., Maxwell, D. J., Gao, X., Bailey, R. E., Han, M., & Nie, S. (2002) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(02)00282-3 · Cited by 2,068
Application of conducting polymers to biosensors
Gerard, M. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00312-8 · Cited by 1,652
Livak, K. J., Flood, S. J., Marmaro, J., Giusti, W., & Deetz, K. (1995) · Genome Research · doi:10.1101/gr.4.6.357 · Cited by 1,603
Koshkin, A. A., Singh, S. K., Nielsen, P., Rajwanshi, V. K., Kumar, R., Meldgaard, M., Olsen, C. E., & Wengel, J. (1998) · Tetrahedron · doi:10.1016/s0040-4020(98)00094-5 · Cited by 1,047
Biosensors for detection of pathogenic bacteria
Ivnitski, D., Abdel-Hamid, I., Atanasov, P., & Wilkins, E. (1999) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(99)00039-1 · Cited by 931
Multiplexed particle-based flow cytometric assays
Vignali, D. A. A. (2000) · Journal of Immunological Methods · doi:10.1016/s0022-1759(00)00238-6 · Cited by 913
The LightCycler TM : A Microvolume Multisample Fluorimeter with Rapid Temperature Control
Wittwer, C. T., Ririe, K. M., Andrew, R. V., David, D. A., Gundry, R. A., & Balis, U. J. (1997) · BioTechniques · doi:10.2144/97221pf02 · Cited by 893
Characterization of intact microorganisms by MALDI mass spectrometry
Fenselau, C., & Demirev, P. A. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10004 · Cited by 834
Detection of PCR products using self-probing amplicons and fluorescence
Whitcombe, D., Theaker, J., Guy, S. P., Brown, T., & Little, S. (1999) · Nature Biotechnology · doi:10.1038/11751 · Cited by 697
Rapid Detection of an Anthrax Biomarker by Surface-Enhanced Raman Spectroscopy
Zhang, X., Young, M. A., Lyandres, O., & Van Duyne, R. P. (2005) · Journal of the American Chemical Society · doi:10.1021/ja043623b · Cited by 682
Multiplexed Toxin Analysis Using Four Colors of Quantum Dot Fluororeagents
Goldman, E. R., Clapp, A. R., Anderson, G. P., Uyeda, H. T., Mauro, J. M., Medintz, I. L., & Mattoussi, H. (2004) · Analytical Chemistry · doi:10.1021/ac035083r · Cited by 651
Discrimination of Bacteria Using Surface-Enhanced Raman Spectroscopy
Jarvis, R. M., & Goodacre, R. (2004) · Analytical Chemistry · doi:10.1021/ac034689c · Cited by 636
Iwamoto, T., Sonobe, T., & Hayashi, K. (2003) · Journal of Clinical Microbiology · doi:10.1128/jcm.41.6.2616-2622.2003 · Cited by 612
Obika, S., Nanbu, D., Hari, Y., Morio, K.-I., In, Y., Ishida, T., & Imanishi, T. (1997) · Tetrahedron Letters · doi:10.1016/s0040-4039(97)10322-7 · Cited by 610
Akane, A., Matsubara, K., Nakamura, H., Takahashi, S., & Kimura, K. (1994) · Journal of Forensic Sciences · doi:10.1520/jfs13607j · Cited by 528
A review of molecular recognition technologies for detection of biological threat agents
Iqbal, S. S., Mayo, M. W., Bruno, J. G., Bronk, B. V., Batt, C. A., & Chambers, J. P. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00108-1 · Cited by 507
MALDI‐TOF mass spectrometry of bacteria*
Lay, J. O. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10003 · Cited by 507
Aptamers as therapeutic and diagnostic agents
Brody, E. N., & Gold, L. (2000) · Reviews in Molecular Biotechnology · doi:10.1016/s1389-0352(99)00004-5 · Cited by 494
Up-converting phosphor reporters for nucleic acid microarrays
Rijke, F. V. D., Zijlmans, H. J. M. A. A., Li, S., Vail, T., Raap, A. K., Niedbala, R. S., & Tanke, H. J. (2001) · Nature Biotechnology · doi:10.1038/85734 · Cited by 492
Spectroscopic Tags Using Dye-Embedded Nanoparticles and Surface-Enhanced Raman Scattering
Doering, W. E., & Nie, S. (2003) · Analytical Chemistry · doi:10.1021/ac034672u · Cited by 470
Pre-PCR Processing : Strategies to Generate PCR-Compatible Samples
Rådström, P., Knutsson, R., Wolffs, P., Lövenklev, M., & Löfström, C. (2004) · Molecular Biotechnology · doi:10.1385/mb:26:2:133 · Cited by 452
Immunoassay Readout Method Using Extrinsic Raman Labels Adsorbed on Immunogold Colloids
Ni, J., Lipert, R. J., Dawson, G. B., & Porter, M. D. (1999) · Analytical Chemistry · doi:10.1021/ac990616a · Cited by 443
Electronic noses and disease diagnostics
Turner, A. P. F., & Magan, N. (2004) · Nature Reviews Microbiology · doi:10.1038/nrmicro823 · Cited by 442
Parida, M., Posadas, G., Inoue, S., Hasebe, F., & Morita, K. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.1.257-263.2004 · Cited by 438
Thai, H. T. C., Le, M. Q., Vuong, C. D., Parida, M., Minekawa, H., Notomi, T., Hasebe, F., & Morita, K. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.5.1956-1961.2004 · Cited by 422
Biological Warfare: A Historical Perspective
Christopher, L. G. W. (1997) · JAMA · doi:10.1001/jama.1997.03550050074036 · Cited by 417
Abu Al-Soud, W., & Rådström, P. (1998) · Applied and Environmental Microbiology · doi:10.1128/aem.64.10.3748-3753.1998 · Cited by 382
Natural and engineered nucleic acids as tools to explore biology
Breaker, R. R. (2004) · Nature · doi:10.1038/nature03195 · Cited by 362
Cheng, J., Sheldon, E. L., Wu, L., Uribe, A., Gerrue, L. O., Carrino, J., Heller, M. J., & O'Connell, J. P. (1998) · Nature Biotechnology · doi:10.1038/nbt0698-541 · Cited by 347
Lapizco‐Encinas, B. H., Simmons, B. A., Cummings, E. B., & Fintschenko, Y. (2004) · ELECTROPHORESIS · doi:10.1002/elps.200405899 · Cited by 347
Aptamer-Based Sensor Arrays for the Detection and Quantitation of Proteins
Kirby, R., Cho, E. J., Gehrke, B., Bayer, T., Park, Y. S., Neikirk, D. P., McDevitt, J. T., & Ellington, A. D. (2004) · Analytical Chemistry · doi:10.1021/ac049858n · Cited by 313
Bacterial Separation and Concentration from Complex Sample Matrices: A Review
Stevens, K. A., & Jaykus, L.-A. (2004) · Critical Reviews in Microbiology · doi:10.1080/10408410490266410 · Cited by 305
Array biosensor for detection of toxins
Ligler, F. S., Taitt, C. R., Shriver-Lake, L. C., Sapsford, K. E., Shubin, Y., & Golden, J. P. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-1992-0 · Cited by 295
Characteristics and Applications of Nucleic Acid Sequence-Based Amplification (NASBA)
Deiman, B., van Aarle, P., & Sillekens, P. (2002) · Molecular Biotechnology · doi:10.1385/mb:20:2:163 · Cited by 294
Multiplex quantitative PCR using self-quenched primers labeled with a single fluorophore
Nazarenko, I. (2002) · Nucleic Acids Research · doi:10.1093/nar/30.9.e37 · Cited by 279
Microsample preparation by dielectrophoresis: isolation of malaria
Gascoyne, P., Mahidol, C., Ruchirawat, M., Satayavivad, J., Watcharasit, P., & Becker, F. F. (2002) · Lab on a Chip · doi:10.1039/b110990c · Cited by 278
A B Cell-Based Sensor for Rapid Identification of Pathogens
Rider, T. H., Petrovick, M. S., Nargi, F. E., Harper, J. D., Schwoebel, E. D., Mathews, R. H., Blanchard, D. J., Bortolin, L. T., Young, A. M., Chen, J., et al. (2003) · Science · doi:10.1126/science.1084920 · Cited by 267
Detection and enumeration of airborne biocontaminants
Stetzenbach, L. D., Buttner, M. P., & Cruz, P. (2004) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2004.04.009 · Cited by 252
Glanders in a Military Research Microbiologist
Srinivasan, A., Kraus, C. N., DeShazer, D., Becker, P. M., Dick, J. D., Spacek, L., Bartlett, J. G., Byrne, W. R., & Thomas, D. L. (2001) · New England Journal of Medicine · doi:10.1056/nejm200107263450404 · Cited by 247
Flow-through immunofiltration assay system for rapid detection of E. coli O157:H7
Abdel-Hamid, I., Ivnitski, D., Atanasov, P., & Wilkins, E. (1999) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(99)00004-4 · Cited by 247
Evaluation of Surface-Enhanced Resonance Raman Scattering for Quantitative DNA Analysis
Faulds, K., Smith, W. E., & Graham, D. (2004) · Analytical Chemistry · doi:10.1021/ac035060c · Cited by 241
Su, X.-L., & Li, Y. (2004) · Analytical Chemistry · doi:10.1021/ac049442+ · Cited by 234
New biochip technology for label-free detection of pathogens and their toxins
Grow, A. E., Wood, L. L., Claycomb, J. L., & Thompson, P. A. (2003) · Journal of Microbiological Methods · doi:10.1016/s0167-7012(03)00026-5 · Cited by 208
A MEMS based amperometric detector for E. Coli bacteria using self-assembled monolayers
Gau, J.-J., Lan, E. H., Dunn, B., Ho, C., & Woo, J. C. S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00216-0 · Cited by 207
Jarman, K. H., Cebula, S. T., Saenz, A. J., Petersen, C. E., Valentine, N. B., Kingsley, M. T., & Wahl, K. L. (2000) · Analytical Chemistry · doi:10.1021/ac990832j · Cited by 204
Microfluidic approaches to malaria detection
Gascoyne, P., Satayavivad, J., & Ruchirawat, M. (2004) · Acta Tropica · doi:10.1016/j.actatropica.2003.11.009 · Cited by 203
Detection of physiologically active compounds using cell-based biosensors
Stenger, D. A., Gross, G. W., Keefer, E. W., Shaffer, K. M., Andreadis, J. D., Ma, W., & Pancrazio, J. J. (2001) · Trends in Biotechnology · doi:10.1016/s0167-7799(01)01690-0 · Cited by 196
Goodey, A., Lavigne, J. J., Savoy, S. M., Rodriguez, M. D., Curey, T., Tsao, A., Simmons, G., Wright, J., Yoo, S.-J., Sohn, Y., et al. (2001) · Journal of the American Chemical Society · doi:10.1021/ja003341l · Cited by 189
Mumy, K. L., & Findlay, R. H. (2004) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2004.01.013 · Cited by 186
Intramolecular Dimers: A New Design Strategy for Fluorescence‐Quenched Probes
Johansson, M. K., & Cook, R. M. (2003) · Chemistry – A European Journal · doi:10.1002/chem.200304941 · Cited by 185
Naimushin, A. N., Soelberg, S. D., Nguyen, D. K., Dunlap, L., Bartholomew, D., Elkind, J., Melendez, J., & Furlong, C. E. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00014-3 · Cited by 183
High-throughput generation and engineering of recombinant human antibodies
Krebs, B., Rauchenberger, R., Reiffert, S. U., Rothe, C., Tesar, M., Thomassen, E., Cao, M., Dreier, T., Fischer, D., Höss, A., et al. (2001) · Journal of Immunological Methods · doi:10.1016/s0022-1759(01)00398-2 · Cited by 178
Slavı́k, R., Homola, J., & Brynda, E. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00013-1 · Cited by 175
Portable cell-based biosensor system using integrated CMOS cell-cartridges
DeBusschere, B. D., & Kovacs, G. T. A. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00168-3 · Cited by 174
Neufeld, T., Schwartz-Mittelmann, A., Biran, D., Ron, E. Z., & Rishpon, J. (2003) · Analytical Chemistry · doi:10.1021/ac026083e · Cited by 172
A Minisonicator To Rapidly Disrupt Bacterial Spores for DNA Analysis
Belgrader, P., Hansford, D., Kovacs, G. T. A., Venkateswaran, K., Mariella, Milanovich, F., Nasarabadi, S., Okuzumi, M., Pourahmadi, F., & Northrup, M. A. (1999) · Analytical Chemistry · doi:10.1021/ac990347o · Cited by 170
Multiplexed Liquid Arrays for Simultaneous Detection of Simulants of Biological Warfare Agents
McBride, M. T., Gammon, S. A., Pitesky, M. E., O'Brien, T. W., Smith, T., Aldrich, J., Langlois, R. G., Colston, B. W., & Venkateswaran, K. S. (2003) · Analytical Chemistry · doi:10.1021/ac026379k · Cited by 169
Hayhurst, A., Happe, S., Mabry, R., Koch, Z., Iverson, B. L., & Georgiou, G. (2003) · Journal of Immunological Methods · doi:10.1016/s0022-1759(03)00100-5 · Cited by 165
Detection and quantification of Escherichia coli O157:H7 in environmental samples by real-time PCR
Ibekwe, A. M., & Grieve, C. M. (2003) · Journal of Applied Microbiology · doi:10.1046/j.1365-2672.2003.01848.x · Cited by 165
Enosawa, M., Kageyama, S., Sawai, K., Watanabe, K., Notomi, T., Onoe, S., Mori, Y., & Yokomizo, Y. (2003) · Journal of Clinical Microbiology · doi:10.1128/jcm.41.9.4359-4365.2003 · Cited by 165
The use of NASBA for the detection of microbial pathogens in food and environmental samples
Cook, N. (2003) · Journal of Microbiological Methods · doi:10.1016/s0167-7012(03)00022-8 · Cited by 165
Park, T., Lee, S., Seong, G. H., Choo, J., Lee, E. K., Kim, Y. S., Ji, W. H., Hwang, S. Y., Gweon, D., & Lee, S. (2005) · Lab on a Chip · doi:10.1039/b414457k · Cited by 163
A rapid assay of endotoxin in whole blood using autologous neutrophil dependent chemiluminescence
Romaschin, A. D., Harris, D. M., Ribeiro, M. B., Paice, J., Foster, D. M., Walker, P. M., & Marshall, J. C. (1998) · Journal of Immunological Methods · doi:10.1016/s0022-1759(98)00003-9 · Cited by 163
Electric Manipulation of Bioparticles and Macromolecules on Microfabricated Electrodes
Huang, Y., Ewalt, K. L., Tirado, M., Haigis, R., Forster, A., Ackley, D., Heller, M. J., O'Connel, J. P., & Krihak, M. (2001) · Analytical Chemistry · doi:10.1021/ac001109s · Cited by 161
Biosensors for the detection of bacteria
Deisingh, A. K., & Thompson, M. (2004) · Canadian Journal of Microbiology · doi:10.1139/w03-095 · Cited by 161
Milk-sense: a volatile sensing system recognises spoilage bacteria and yeasts in milk
Magan, N., Pavlou, A. K., & Chrysanthakis, I. (2001) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(00)00621-3 · Cited by 159
Detection of Human Influenza A Viruses by Loop-Mediated Isothermal Amplification
Poon, L. L. M., Leung, C. S. W., Chan, K. H., Lee, J. H. C., Yuen, K. Y., Guan, Y., & Peiris, J. S. M. (2005) · Journal of Clinical Microbiology · doi:10.1128/jcm.43.1.427-430.2005 · Cited by 159
Reagentless Detection and Classification of Individual Bioaerosol Particles in Seconds
Fergenson, D. P., Pitesky, M. E., Tobias, H. J., Steele, P. T., Czerwieniec, G. A., Russell, S. C., Lebrilla, C. B., Horn, J. M., Coffee, K. R., Srivastava, A., et al. (2004) · Analytical Chemistry · doi:10.1021/ac034467e · Cited by 157
Bell, S. E. J., Mackle, J. N., & Sirimuthu, N. M. S. (2005) · The Analyst · doi:10.1039/b415290e · Cited by 155
Immunomagnetic separation and PCR for detection of Helicobacter pylori in water and stool specimens
Enroth, H., & Engstrand, L. G. (1995) · Journal of Clinical Microbiology · doi:10.1128/jcm.33.8.2162-2165.1995 · Cited by 154
Karch, H., Janetzki-Mittmann, C., Aleksic, S., & Datz, M. (1996) · Journal of Clinical Microbiology · doi:10.1128/jcm.34.3.516-519.1996 · Cited by 150
Schneider, P., Wolters, L., Schoone, G., Schallig, H., Sillekens, P., Hermsen, R., & Sauerwein, R. (2005) · Journal of Clinical Microbiology · doi:10.1128/jcm.43.1.402-405.2005 · Cited by 146
Loop-Mediated Isothermal Amplification for Rapid Detection of Newcastle Disease Virus
Pham, H. M., Nakajima, C., Ohashi, K., & Onuma, M. (2005) · Journal of Clinical Microbiology · doi:10.1128/jcm.43.4.1646-1650.2005 · Cited by 146
Biological Weapons—a Primer for Microbiologists
Hawley, R. J., & Eitzen Jr, E. M. (2001) · Annual Review of Microbiology · doi:10.1146/annurev.micro.55.1.235 · Cited by 146
Electronic sensors with living cellular components
Kovacs, G. T. A. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.813580 · Cited by 138
Application of luminescent nanocrystals as labels for biological molecules
Riegler, J., & Nann, T. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2706-y · Cited by 137
Zhu, L., Ang, S. S., & Liu, W. (2004) · Applied and Environmental Microbiology · doi:10.1128/aem.70.1.597-598.2004 · Cited by 133
Kulesh, D. A., Baker, R. O., Loveless, B. M., Norwood, D., Zwiers, S. H., Mucker, E. M., Hartmann, C., Herrera, R., Miller, D., Christensen, D. R., et al. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.2.601-609.2004 · Cited by 130
Biosensor technologies for detecting microbiological foodborne hazards
HALL, R. H. (2002) · Microbes and Infection · doi:10.1016/s1286-4579(02)01556-3 · Cited by 128
Pancrazio, J. J., Gray, S. A., Shubin, Y. S., Kulagina, N. V., Cuttino, D. S., Shaffer, K. M., Eisemann, K., Curran, A., Zim, B., Gross, G. W., et al. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00092-7 · Cited by 127
Effectiveness of protein A for antibody immobilization for a fiber optic biosensor
Anderson, G. P., Jacoby, M. A., Ligler, F. S., & King, K. D. (1997) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(96)00074-7 · Cited by 127
Ruan, C., Zeng, K., Varghese, O. K., & Grimes, C. A. (2003) · Analytical Chemistry · doi:10.1021/ac034562n · Cited by 125
Anticoagulants Interfere with PCR Used To Diagnose Invasive Aspergillosis
García, M. E., Blanco, J. L., Caballero, J., & Gargallo-Viola, D. (2002) · Journal of Clinical Microbiology · doi:10.1128/jcm.40.4.1567-1568.2002 · Cited by 123
Rijpens, N. P., Herman, L., Vereecken, F., Jannes, G., Smedt, J. D., & Zutter, L. D. (1999) · International Journal of Food Microbiology · doi:10.1016/s0168-1605(98)00171-8 · Cited by 117
Uyttendaele, M., Hoorde, I. V., & Debevere, J. (2000) · International Journal of Food Microbiology · doi:10.1016/s0168-1605(99)00196-8 · Cited by 114
Detection of biological threats. A challenge for directed molecular evolution
Petrenko, V. A., & Sorokulova, I. B. (2004) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2004.04.004 · Cited by 113
DiGiorgio, C. L., Gonzalez, D. A., & Huitt, C. C. (2002) · Applied and Environmental Microbiology · doi:10.1128/aem.68.12.5952-5955.2002 · Cited by 111
Real-Time PCR Method for Detection of Encephalitozoonintestinalis from Stool Specimens
Wolk, D. M., Schneider, S. K., Wengenack, N. L., Sloan, L. M., & Rosenblatt, J. E. (2002) · Journal of Clinical Microbiology · doi:10.1128/jcm.40.11.3922-3928.2002 · Cited by 109
Devic, E., Li, D., Dauta, A., Henriksen, P., Codd, G. A., Marty, J., & Fournier, D. D. (2002) · Applied and Environmental Microbiology · doi:10.1128/aem.68.8.4102-4106.2002 · Cited by 104
A Portable Array Biosensor for Detecting Multiple Analytes in Complex Samples
Taitt, C. R., Golden, J. P., Shubin, Y. S., Shriver‐Lake, L. C., Sapsford, K. E., Rasooly, A., & Ligler, F. S. (2004) · Microbial Ecology · doi:10.1007/s00248-003-1011-1 · Cited by 104
Direct PCR detection of Escherichia coli O157:H7
Vaughan, K. A., Maki, J. S., Benson, J. A., & Collins, M. L. P. (2003) · Letters in Applied Microbiology · doi:10.1046/j.1472-765x.2003.01386.x · Cited by 101
Investigation of MALDI-TOF and FT-MS Techniques for Analysis of Escherichia coli Whole Cells
Jones, J. J., Stump, M. J., Fleming, R. C., Lay, J. O., & Wilkins, C. L. (2003) · Analytical Chemistry · doi:10.1021/ac026213j · Cited by 99
A Miniature Biochip System for Detection of Aerosolized Bacillus globigii Spores
Stratis‐Cullum, D. N., Griffin, G. D., Mobley, J., Vass, A. A., & Vo‐Dinh, T. (2002) · Analytical Chemistry · doi:10.1021/ac026068+ · Cited by 99
Seki, M., Yamashita, Y., Torigoe, H., Tsuda, H., Sato, S., & Maeno, M. (2005) · Journal of Clinical Microbiology · doi:10.1128/jcm.43.4.1581-1586.2005 · Cited by 99
Biagini, R. E., Sammons, D. L., Smith, J. P., MacKenzie, B. A., Striley, C., Semenova, V. A., Steward‐Clark, E., Stamey, K., Freeman, A. E., Quinn, C. P., et al. (2004) · Clinical and Vaccine Immunology · doi:10.1128/cdli.11.1.50-55.2004 · Cited by 96
Real-Time PCR Assay To Detect Smallpox Virus
Ibrahim, M. S., Kulesh, D. A., Saleh, S. S., Damon, I. K., Esposito, J. J., Schmaljohn, A. L., & Jahrling, P. B. (2003) · Journal of Clinical Microbiology · doi:10.1128/jcm.41.8.3835-3839.2003 · Cited by 95
Diagnostic Probes for Bacillus anthracis Spores Selected from a Landscape Phage Library
Brigati, J. R., Williams, D. D., Sorokulova, I. B., et al. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.038018 · Cited by 94
Buttner, M. P., Cruz, P., Stetzenbach, L. D., Klima-Comba, A. K., Stevens, V., & Cronin, T. D. (2004) · Applied and Environmental Microbiology · doi:10.1128/aem.70.8.4740-4747.2004 · Cited by 91
Hsih, H.-Y., & Tsen, H. (2001) · Journal of Food Protection · doi:10.4315/0362-028x-64.11.1744 · Cited by 91
Species-Specific Peptide Ligands for the Detection of Bacillus anthracis Spores
Williams, D. D., Benedek, O., & Turnbough, C. L. (2003) · Applied and Environmental Microbiology · doi:10.1128/aem.69.10.6288-6293.2003 · Cited by 84
Discovery of phage display peptide ligands for species-specific detection of Bacillus spores
Turnbough, C. L. (2003) · Journal of Microbiological Methods · doi:10.1016/s0167-7012(03)00030-7 · Cited by 84
Wolffs, P. F. G., Knutsson, R., Norling, B., & Rådström, P. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.3.1042-1047.2004 · Cited by 84
Lee, L. Y., Ong, S. L., Hu, J. Y., Ng, W. J., Feng, Y., Tan, X., & Wong, S. W. (2004) · Applied and Environmental Microbiology · doi:10.1128/aem.70.10.5732-5736.2004 · Cited by 78
Keshri, G., Voysey, P. A., & Magan, N. (2002) · Journal of Applied Microbiology · doi:10.1046/j.1365-2672.2002.01515.x · Cited by 77
Simultaneous detection of diverse analytes with an aptazyme ligase array
Hesselberth, J. R., Robertson, M. P., Knudsen, S. M., & Ellington, A. D. (2003) · Analytical Biochemistry · doi:10.1016/s0003-2697(02)00441-4 · Cited by 75
Chandrasekar, P. H., & Ito, J. I. (2005) · Clinical Infectious Diseases · doi:10.1086/429333 · Cited by 73
Warscheid, B., & Fenselau, C. (2004) · PROTEOMICS · doi:10.1002/pmic.200400911 · Cited by 72
General purpose, field-portable cell-based biosensor platform
Gilchrist, K. H., Barker, V., Fletcher, L. E., DeBusschere, B. D., Ghanouni, P., Giovangrandi, L., & Kovacs, G. T. A. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00169-5 · Cited by 69
Woodbury, R. G., Wendin, C., Clendenning, J. B., et al. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(98)00060-8 · Cited by 68
Makino, S., & Cheun, H. (2003) · Journal of Microbiological Methods · doi:10.1016/s0167-7012(03)00019-8 · Cited by 68
Recognition of anaerobic bacterial isolates in vitro using electronic nose technology
Pavlou, A., Turner, A. P. F., & Magan, N. (2002) · Letters in Applied Microbiology · doi:10.1046/j.1472-765x.2002.01197.x · Cited by 67
Yoo, J., Choi, J.-H., Choi, S., Lee, D., Shin, W. S., Min, W. S., & Kim, C.-C. (2005) · Clinical Infectious Diseases · doi:10.1086/427284 · Cited by 62
Optimization of PCR based detection of human papillomavirus DNA from urine specimens
Brinkman, J. A., Rahmani, M. Z., Jones, W., Chaturvedi, A. K., & Hagensee, M. E. (2003) · Journal of Clinical Virology · doi:10.1016/s1386-6532(03)00157-4 · Cited by 61
Improved amplification of cytomegalovirus DNA from urine after purification of DNA with glass beads
Buffone, G. J., Demmler, G. J., Schimbor, C. M., & Greer, J. M. (1991) · Clinical Chemistry · doi:10.1093/clinchem/37.11.1945 · Cited by 61
A genetically engineered cell-based biosensor for functional classification of agents
Aravanis, A. M., DeBusschere, B. D., Chruscinski, A. J., Gilchrist, K. H., Kobilka, B. K., & Kovacs, G. T. A. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00171-3 · Cited by 58
Chandler, D. P. (2001) · International Journal of Food Microbiology · doi:10.1016/s0168-1605(01)00536-0 · Cited by 58
Ert, M. N. V., Hofstadler, S. A., Jiang, Y., Busch, J. D., Wagner, D. M., Drader, J. J., Ecker, D. J., Hannis, J. C., Huynh, L. Y., Schupp, J. M., et al. (2004) · BioTechniques · doi:10.2144/04374rr01 · Cited by 57
Removal of PCR inhibitors using dielectrophoresis as a selective filter in a microsystem
Perch-Nielsen, I. R., Bang, D. D., Poulsen, C., El-Ali, J., & Wolff, A. (2003) · Lab on a Chip · doi:10.1039/b304549h · Cited by 52
Design and demonstration of an automated cell-based biosensor
Gray, S. A., Kusel, J. K., Shaffer, K. M., Shubin, Y. S., Stenger, D. A., & Pancrazio, J. J. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00167-1 · Cited by 51
PCR identification of Salmonella cells in food and stool samples after immunomagnetic separation
Španová, A., Rittich, B., Karpíšková, R., Buňková, L., & Škapová, D. (2000) · Bioseparation · doi:10.1023/a:1011125014586 · Cited by 50
Development of a novel FRET immunosensor technique
Lichlyter, D. J., Grant, S. A., & Soykan, O. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00215-x · Cited by 48
Growth behavior of microorganisms using UV‐Vis spectroscopy: Escherichia coli
Alupoaei, C. E., & García‐Rubio, L. H. (2004) · Biotechnology and Bioengineering · doi:10.1002/bit.20001 · Cited by 47
Nucleic Acid Amplification Assays for Detection of La Crosse Virus RNA
Lambert, A. J., Nasci, R. S., Cropp, B. C., Martin, D. A., Rose, B. C., Russell, B. J., & Lanciotti, R. S. (2005) · Journal of Clinical Microbiology · doi:10.1128/jcm.43.4.1885-1889.2005 · Cited by 45
Furukawa, H., Doh‐ura, K., Okuwaki, R., Shirabe, S., Yamamoto, K., Udono, H., Ito, T., Katamine, S., & Niwa, M. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m400187200 · Cited by 45
Deng, X. K., Nesbit, L. A., & Morrow, K. J. (2003) · Clinical and Vaccine Immunology · doi:10.1128/cdli.10.4.587-595.2003 · Cited by 43
Affinity Purification of DNA and RNA from Environmental Samples with Peptide Nucleic Acid Clamps
Chandler, D. P., Stults, J. R., Cebula, S., Schuck, B. L., Weaver, D. W., Anderson, K. K., Egholm, M., & Brockman, F. J. (2000) · Applied and Environmental Microbiology · doi:10.1128/aem.66.8.3438-3445.2000 · Cited by 41
Taxonomic identification of microorganisms by capture and intrinsic fluorescence detection
Mason, H.-Y., Lloyd, C. R., Dice, M. S., Sinclair, R., Ellis, W. R., & Powers, L. S. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00010-1 · Cited by 41
Chaplen, F. W. R., Upson, R. H., McFadden, P. N., & Kolodziej, W. (2002) · Pigment Cell Research · doi:10.1034/j.1600-0749.2002.00069.x · Cited by 39
Molecular Diagnosis of Infectious Diseases
Reischl, U. (1997) · Humana Press eBooks · doi:10.1385/0896034852 · Cited by 37
Early recognition of atypical Francisella tularensis strains lacking a cysteine requirement
Bernard, K. A., Tessier, S., Winstanley, J., Chang, D. P. S., & Borczyk, A. A. (1994) · Journal of Clinical Microbiology · doi:10.1128/jcm.32.2.551-553.1994 · Cited by 37
Multiple labelled nanoparticles for bio detection
Docherty, F. T., Clark, M., McNay, G., Graham, D., & Smith, W. E. (2003) · Faraday Discussions · doi:10.1039/b306684c · Cited by 35
Potential applications of DNA microarrays in biodefense-related diagnostics
Stenger, D. A., Andreadis, J. D., Voraa, G. J., & Pancrazio, J. J. (2002) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(02)00321-x · Cited by 31
Rau, D., Kramer, K., & Hock, B. (2002) · Journal of Immunoassay and Immunochemistry · doi:10.1081/ias-120003657 · Cited by 30
Responses of fish chromatophore‐based cytosensor to a broad range of biological agents
Dierksen, K. P., Mojović, L. V., Caldwell, B. A., Preston, R. R., Upson, R. H., Lawrence, J. R., McFadden, P. N., & Trempy, J. E. (2004) · Journal of Applied Toxicology · doi:10.1002/jat.1030 · Cited by 26
Watanabe, T. (1998) · Scandinavian Journal of Gastroenterology · doi:10.1080/00365529850172476 · Cited by 26
Real-time detection of microbial contamination
Kim, H.-Y., Estes, C., Duncan, A., Wade, B., Cleary, F. C., Lloyd, C. R., Ellis, W. R., & Powers, L. (2004) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2004.1297183 · Cited by 23
Particle visualisation - a tool for determination of rise velocities
Ljunggren, M., Jönsson, L., & Jansen, J. L. C. (2004) · Water Science & Technology · doi:10.2166/wst.2004.0718 · Cited by 13
Molecular diagnosis of infectious diseases
Raj, P. (1997) · The Indian Journal of Pediatrics · doi:10.1007/bf02737744 · Cited by 13
Shedding Light on Microbial Detection
Relman, D. A. (2003) · New England Journal of Medicine · doi:10.1056/nejmcibr035737 · Cited by 13
A low-cost, portable generic biotoxicity assay for environmental monitoring applications
Sharma, V. K., Narayanan, A., Rengachari, T., Temes, G. C., Chaplen, F. W. R., & Moon, U.-K. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.07.023 · Cited by 13
FiltraCheck-UTI, a rapid, disposable system for detection of bacteriuria
Longoria, C. C., & Gonzalez, G. A. (1987) · Journal of Clinical Microbiology · doi:10.1128/jcm.25.5.926-928.1987 · Cited by 9
Pratt-Rippin, K., Stinson, W. C., Eisenstadt, J., & Washington, J. A. (1995) · American Journal of Clinical Pathology · doi:10.1093/ajcp/103.3.316 · Cited by 8
le Roux, W. J., Masoabi, D., de Wet, C. M. E., & Venter, S. N. (2004) · Water Science & Technology · doi:10.2166/wst.2004.0059 · Cited by 8
Cited by
Primary biological aerosol particles in the atmosphere: a review
Després, V. R., Huffman, J. A., Burrows, S. M., Hoose, C., Safatov, A. S., Buryak, G., Fröhlich-Nowoisky, J., Elbert, W., Andreae, M. O., Pöschl, U., et al. (2012) · Tellus B: Chemical and Physical Meteorology · doi:10.3402/tellusb.v64i0.15598 · Cited by 1,500
“Several reviews of modern techniques of biological aerosol detection and analysis have been published (Spurny, 1994; Ho, 2002; Douwes et al., 2003; Lim et al., 2005; Kuske, 2006) and so, again, only highlights of important classes of non-optical modern techniques will be discussed here.”
Pathogen detection: A perspective of traditional methods and biosensors
Lazcka, O., Campo, F. J. D., & Muñoz, F. X. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.06.036 · Cited by 1,500
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Importance of the Debye Screening Length on Nanowire Field Effect Transistor Sensors
Stern, E., Wagner, R., Sigworth, F. J., Breaker, R., Fahmy, T. M., & Reed, M. A. (2007) · Nano Letters · doi:10.1021/nl071792z · Cited by 806
Luka, G., Ahmadi, A., Najjaran, H., Alocilja, E., DeRosa, M., Wolthers, K., Malki, A., Aziz, H., Althani, A., & Hoorfar, M. (2015) · Sensors · doi:10.3390/s151229783 · Cited by 566
Metadata
- Authors
- Lim, D. V., Simpson, J. M., Kearns, E. A., & Kramer, M. F.
- Venue
- Clinical Microbiology Reviews
- Publisher
- American Society for Microbiology
- Published
- 2005-10
- Volume
- 18
- Issue
- 4
- Pages
- 583-607
- ISSN
- 0893-8512 (ISSN-L)
- 1098-6618
- OpenAlex
- W2162075284
- Cited by
- 417
- References
- 150
- FWCI
- 22.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.