Noninvasive Human Brain Stimulation
The DOI matches its Crossref record; 116 of the 116 references it cites were found in a registry or an index.
Abstract
Noninvasive brain stimulation with transcranial magnetic stimulation (TMS) or transcranial direct current stimulation (tDCS) is valuable in research and has potential therapeutic applications in cognitive neuroscience, neurophysiology, psychiatry, and neurology. TMS allows neurostimulation and neuromodulation, while tDCS is a purely neuromodulatory application. TMS and tDCS allow diagnostic and interventional neurophysiology applications, and focal neuropharmacology delivery. However, the physics and basic mechanisms of action remain incompletely explored. Following an overview of the history and current applications of noninvasive brain stimulation, we review stimulation device design principles, the electromagnetic and physical foundations of the techniques, and the current knowledge about the electrophysiologic basis of the effects. Finally, we discuss potential biomedical and electrical engineering developments that could lead to more effective stimulation devices, better suited for the specific applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hodgkin, A. L., & Huxley, A. F. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004764 · Cited by 23,191 · cited 1×
“To further increase the detail of the model, one could include the active properties of the axon by implementing the Hodgkin & Huxley model (64), which includes the voltage/time-dependent sodium and potassium channels represented by gK and gNa (conductances per unit area for sodium and potassium), respectively; the st…”
MethodTheta Burst Stimulation of the Human Motor Cortex
Huang, Y.-Z., Edwards, M. J., Rounis, E., Bhatia, K. P., & Rothwell, J. C. (2005) · Neuron · doi:10.1016/j.neuron.2004.12.033 · Cited by 4,158
Strafella, A. P., Paus, T., Barrett, J., & Dagher, A. (2001) · The Journal of Neuroscience · doi:10.1523/jneurosci.21-15-j0003.2001 · Cited by 1,058
Bindman, L. J., Lippold, O. C. J., & Redfearn, J. W. T. (1964) · The Journal of Physiology · doi:10.1113/jphysiol.1964.sp007425 · Cited by 978
INTRACELLULAR ACTIVITIES AND EVOKED POTENTIAL CHANGES DURING POLARIZATION OF MOTOR CORTEX
Purpura, D. P., & McMurtry, J. G. (1965) · Journal of Neurophysiology · doi:10.1152/jn.1965.28.1.166 · Cited by 870
Lang, N., Siebner, H. R., Ward, N. S., Lee, L., Nitsche, M. A., Paulus, W., Rothwell, J. C., Lemon, R. N., & Frackowiak, R. S. (2005) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2005.04233.x · Cited by 769
Paus, T., Jech, R., Thompson, C. J., Comeau, R., Peters, T., & Evans, A. C. (1997) · The Journal of Neuroscience · doi:10.1523/jneurosci.17-09-03178.1997 · Cited by 700
The physiological basis of transcranial motor cortex stimulation in conscious humans
Di Lazzaro, V, Oliviero, A., Pilato, F., Saturno, E., Dileone, M., Mazzone, P., Insola, A., Tonali, P. A., & Rothwell, J. C. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2003.10.009 · Cited by 584
Transcranial direct current stimulation: A computer-based human model study
Wagner, T., Fregni, F., Fecteau, S., Grodzinsky, A., Zahn, M., & Pascual-Leone, A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.01.027 · Cited by 567
Self-citationStrafella, A. P. (2003) · Brain · doi:10.1093/brain/awg268 · Cited by 559
Transcranial direct current stimulation during sleep improves declarative memory
Marshall, L., Mölle, M., Hallschmid, M., & Born, J. (2004) · The Journal of Neuroscience · doi:10.1523/jneurosci.2725-04.2004 · Cited by 548 · cited 1×
“Other researchers combined these modalities while studying sleep (136) and visual processes (137).”
BackgroundCurrent Distribution in the Brain From Surface Electrodes
RUSH, S., & DRISCOLL, D. A. (1968) · Anesthesia & Analgesia · doi:10.1213/00000539-196811000-00016 · Cited by 521
Priori, A. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00437-6 · Cited by 508
Electrical stimulation of neural tissue to evoke behavioral responses
Tehovnik, E. J. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00131-x · Cited by 478 · cited 1×
“20 A/m2 compared to 22 to 275 A/m2 (53)], these tDCS magnitudes have been shown to influence spontaneous activity and characteristics of the evoked response from cortical neurons (45, 46, 54).”
BackgroundTranscranial magnetic stimulation of deep brain regions: evidence for efficacy of the H-Coil
Zangen, A., Roth, Y., Voller, B., & Hallett, M. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.11.008 · Cited by 473
Bestmann, S., Baudewig, J., Siebner, H. R., Rothwell, J. C., & Frahm, J. (2004) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2004.03277.x · Cited by 455
Pascual-Leone, A. (1999) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1999.0476 · Cited by 454
Self-citationGerloff, C., Bushara, K., Sailer, A., Wassermann, E. M., Chen, R., Matsuoka, T., Waldvogel, D., Wittenberg, G. F., Ishii, K., Cohen, L. G., et al. (2006) · Brain · doi:10.1093/brain/awh713 · Cited by 452
Ueno, S., Tashiro, T., & Harada, K. (1988) · Journal of Applied Physics · doi:10.1063/1.342181 · Cited by 442
Ardolino, G., Bossi, B., Barbieri, S., & Priori, A. (2005) · The Journal of Physiology · doi:10.1113/jphysiol.2005.088310 · Cited by 430
Analysis of models for extracellular fiber stimulation
Rattay, F. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32099 · Cited by 420
Effects of coil design on delivery of focal magnetic stimulation. Technical considerations
Cohen, L. G., Roth, B. J., Nilsson, J., Dang, N., Panizza, M., Bandinelli, S., Friauf, W., & Hallett, M. (1990) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(90)90113-x · Cited by 409
Imaging human intra-cerebral connectivity by PET during TMS
Fox, P., Ingham, R., George, M. S., Mayberg, H., Ingham, J., Roby, J., Martin, C., & Jerabek, P. (1997) · NeuroReport · doi:10.1097/00001756-199708180-00027 · Cited by 395
Antal, A., Kincses, T. Z., Nitsche, M. A., Bartfai, O., & Paulus, W. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-0688 · Cited by 382
A model of the stimulation of a nerve fiber by electromagnetic induction
Roth, B. J., & Basser, P. J. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55662 · Cited by 363
Iyer, M. B., Schleper, N., & Wassermann, E. M. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-34-10867.2003 · Cited by 360
Three-Dimensional Head Model Simulation of Transcranial Magnetic Stimulation
Wagner, T. A., Zahn, M., Grodzinsky, A. J., & Pascual-Leone, A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827925 · Cited by 348
Self-citationA Coil Design for Transcranial Magnetic Stimulation of Deep Brain Regions
Roth, Y., Zangen, A., & Hallett, M. (2002) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200208000-00008 · Cited by 326
Maccabee, P. J., Amassian, V. E., Eberle, L. P., & Cracco, R. Q. (1993) · The Journal of Physiology · doi:10.1113/jphysiol.1993.sp019467 · Cited by 321
BINDMAN, L. J., LIPPOLD, O. C. J., & REDFEARN, J. W. T. (1962) · Nature · doi:10.1038/196584a0 · Cited by 314
A theoretical calculation of the electric field induced in the cortex during magnetic stimulation
Roth, B. J., Saypol, J. M., Hallett, M., & Cohen, L. G. (1991) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(91)90103-5 · Cited by 307
A combined TMS/fMRI study of intensity-dependent TMS over motor cortex
Bohning, D., Shastri, A., McConnell, K., Nahas, Z., Lorberbaum, J., Roberts, D., Teneback, C., Vincent, D., & George, M. (1999) · Biological Psychiatry · doi:10.1016/s0006-3223(98)00368-0 · Cited by 301
Lee, L., Siebner, H. R., Rowe, J. B., Rizzo, V., Rothwell, J. C., Frackowiak, R. S. J., & Friston, K. J. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-12-05308.2003 · Cited by 289
Nathan, S. S., Sinha, S. R., Gordon, B., Lesser, R. P., & Thakor, N. V. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90006-h · Cited by 267
Effect of transcranial magnetic stimulation on single‐unit activity in the cat primary visual cortex
Moliadze, V., Zhao, Y., Eysel, U., & Funke, K. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2003.050153 · Cited by 248
MEASUREMENT OF IMPOSED VOLTAGE GRADIENT ADEQUATE TO MODULATE NEURONAL FIRING
Terzuolo, C. A., & Bullock, T. H. (1956) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.42.9.687 · Cited by 247
Amassian, V. E., Eberle, L., Maccabee, P. J., & Cracco, R. Q. (1992) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(92)90105-k · Cited by 240
Baudewig, J., Nitsche, M. A., Paulus, W., & Frahm, J. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200102)45:2<196::aid-mrm1026>3.0.co;2-1 · Cited by 238
Paus, T., Jech, R., Thompson, C. J., Comeau, R., Peters, T., & Evans, A. C. (1998) · Journal of Neurophysiology · doi:10.1152/jn.1998.79.2.1102 · Cited by 227
Liebetanz, D., Klinker, F., Hering, D., Koch, R., Nitsche, M. A., Potschka, H., Löscher, W., Paulus, W., & Tergau, F. (2006) · Epilepsia · doi:10.1111/j.1528-1167.2006.00539.x · Cited by 224
Miranda, P. C., Hallett, M., & Basser, P. J. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.816079 · Cited by 215
Echoplanar BOLD fMRI of brain activation induced by concurrent transcranial magnetic stimulation
BOHNING, D. E., SHASTRI, A., NAHAS, Z., LORBERBAUM, J. P., ANDERSEN, S. W., DANNELS, W. R., HAXTHAUSEN, E.-U., VINCENT, D. J., & GEORGE, M. S. (1998) · Investigative Radiology · doi:10.1097/00004424-199806000-00004 · Cited by 210
Post, A., & Keck, M. E. (2001) · Journal of Psychiatric Research · doi:10.1016/s0022-3956(01)00023-1 · Cited by 209
Plewnia, C., Reimold, M., Najib, A., Brehm, B., Reischl, G., Plontke, S. K., & Gerloff, C. (2007) · Human Brain Mapping · doi:10.1002/hbm.20270 · Cited by 208
Repetitive transcranial magnetic stimulation activates specific regions in rat brain
Ji, R.-R., Schlaepfer, T. E., Aizenman, C. D., Epstein, C. M., Qiu, D., Huang, J. C., & Rupp, F. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.26.15635 · Cited by 197
LTD and LTP induced by transcranial magnetic stimulation in auditory cortex
Wang, H., Wang, X., & Scheich, H. (1996) · NeuroReport · doi:10.1097/00001756-199601310-00035 · Cited by 192
Effects of induced electric fields on finite neuronal structures: a simulation study
Nagarajan, S. S., Durand, D. M., & Warman, E. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.245636 · Cited by 187
Brain stimulation using electromagnetic sources: theoretical aspects
Heller, L., & van Hulsteyn, D. B. (1992) · Biophysical Journal · doi:10.1016/s0006-3495(92)81587-4 · Cited by 178
POGARELL, O., KOCH, W., POPPERL, G., TATSCH, K., JAKOB, F., ZWANZGER, P., MULERT, C., RUPPRECHT, R., MOLLER, H., & HEGERL, U. (2006) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2005.09.001 · Cited by 177
Application of focused ultrasound for the stimulation of neural structures
Gavrilov, L. R., Tsirulnikov, E. M., & Davies, I. A. I. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(96)83782-3 · Cited by 173
Corticostriatal functional interactions in Parkinson's disease: a rTMS/[11C]raclopride PET study
Strafella, A. P., Ko, J. H., Grant, J., Fraraccio, M., & Monchi, O. (2005) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2005.04476.x · Cited by 172
Imaging the brain before, during, and after transcranial magnetic stimulation
Paus, T. (1998) · Neuropsychologia · doi:10.1016/s0028-3932(98)00096-7 · Cited by 172
Functional MRI of cortical activations induced by transcranial magnetic stimulation (TMS)
Baudewig, J., Siebner, H. R., Bestmann, S., Tergau, F., Tings, T., Paulus, W., & Frahm, J. (2001) · Neuroreport · doi:10.1097/00001756-200111160-00034 · Cited by 168
Keck, M. E., Sillaber, I., Ebner, K., Welt, T., Toschi, N., Kaehler, S. T., Singewald, N., Philippu, A., Elbel, G. K., Wotjak, C. T., et al. (2000) · European Journal of Neuroscience · doi:10.1046/j.1460-9568.2000.00243.x · Cited by 164
Mapping transcranial magnetic stimulation (TMS) fields in vivo with MRI
Bohning, D. E., Pecheny, A. P., Epstein, C. M., Speer, A. M., Vincent, D. J., Dannels, W., & George, M. S. (1997) · NeuroReport · doi:10.1097/00001756-199707280-00023 · Cited by 163
Speer, A. M., Willis, M. W., Herscovitch, P., Daube-Witherspoon, M. E., Shelton, J. R., Benson, B. E., Post, R. M., & Wassermann, E. M. (2003) · Biological Psychiatry · doi:10.1016/s0006-3223(03)00002-7 · Cited by 162
Stimulation of a myelinated nerve axon by electromagnetic induction
Basser, P. J., & Roth, B. J. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446708 · Cited by 162
Developing a More Focal Magnetic Stimulator. Part I: Some Basic Principles
Cohen, D., & Cuffin, B. N. (1991) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199101000-00013 · Cited by 159
The distribution of induced currents in magnetic stimulation of the nervous system
Tofts, P. S. (1990) · Physics in Medicine and Biology · doi:10.1088/0031-9155/35/8/008 · Cited by 159
Modeling the Effects of Transcranial Magnetic Stimulation on Cortical Circuits
Esser, S. K., Hill, S. L., & Tononi, G. (2005) · Journal of Neurophysiology · doi:10.1152/jn.01230.2004 · Cited by 157
Predicted current densities in the brain during transcranial electrical stimulation
Holdefer, R. N., Sadleir, R., & Russell, M. J. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.02.020 · Cited by 154
Keck, M. E., Welt, T., Post, A., Müller, M. B., Toschi, N., Wigger, A., Landgraf, R., Holsboer, F., & Engelmann, M. (2001) · Neuropsychopharmacology · doi:10.1016/s0893-133x(00)00191-3 · Cited by 149
After-effects of transcranial direct current stimulation (tDCS) on cortical spreading depression
Liebetanz, D., Fregni, F., Monte-Silva, K. K., de Oliveira, M. B., dos Santos, Â. A., Nitsche, M. A., & Guedes, R. C. A. (2006) · Neuroscience Letters · doi:10.1016/j.neulet.2005.12.058 · Cited by 148
Eaton, H. (1992) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446182 · Cited by 141
Valero-Cabré, A., Payne, B. R., & Pascual-Leone, A. (2007) · Experimental Brain Research · doi:10.1007/s00221-006-0639-8 · Cited by 137
Self-citationA new device and protocol for combining TMS and online recordings of EEG and evoked potentials
Thut, G., Ives, J. R., Kampmann, F., Pastor, M. A., & Pascual‐Leone, Á. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.06.016 · Cited by 135
Computation of electric and magnetic stimulation in human head using the 3-D impedance method
Nadeem, M., Thorlin, T., Gandhi, O. P., & Persson, M. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813548 · Cited by 133
Human cerebral cortical responses to contralateral transcranial stimulation
Amassian, V. E., & Cracco, R. Q. (1987) · Neurosurgery · doi:10.1097/00006123-198701000-00031 · Cited by 132
Valero-Cabré, A., Payne, B. R., Rushmore, J., Lomber, S. G., & Pascual-Leone, A. (2005) · Experimental Brain Research · doi:10.1007/s00221-004-2140-6 · Cited by 132
Self-citationTranscranial magnetic stimulation and stroke: A computer-based human model study
Wagner, T., Fregni, F., Eden, U. T., Ramos-Estébanez, C., Grodzinsky, A. J., Zahn, M., & Pascual‐Leone, Á. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.04.046 · Cited by 125
Self-citationPost, A., Müller, M. B., Engelmann, M., & Keck, M. E. (1999) · European Journal of Neuroscience · doi:10.1046/j.1460-9568.1999.00747.x · Cited by 121
Siebner, H. R., Takano, B., Peinemann, A., Schwaiger, M., Conrad, B., & Drzezga, A. E. (2001) · NeuroImage · doi:10.1006/nimg.2001.0889 · Cited by 115
The electric field induced during magnetic stimulation.
Roth, B. J., Cohen, L. G., & Hallett, M. (1991) · PubMed · Cited by 112
Lisanby, S. H., & Belmaker, R. H. (2000) · Depression and Anxiety · doi:10.1002/1520-6394(2000)12:3<178::aid-da10>3.0.co;2-n · Cited by 106
Intracerebral current levels in man during electrosleep therapy.
Dymond, A. M., Coger, R., & Serafetinides, E. A. (1975) · PubMed · Cited by 105
Speer, A. M., Willis, M. W., Herscovitch, P., Daube-Witherspoon, M. E., Shelton, J. R., Benson, B. E., Post, R. M., & Wassermann, E. M. (2003) · Biological Psychiatry · doi:10.1016/s0006-3223(03)00324-x · Cited by 105
An analysis of peripheral motor nerve stimulation in humans using the magnetic coil
Maccabee, P. J., Amassian, V. E., Cracco, R. Q., & Cadwell, J. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90150-2 · Cited by 101
Maccabee, P. J., Eberle, L., Amassian, V. E., Cracco, R. Q., & Rudell, A. P. (1990) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(90)90211-2 · Cited by 100
Transcranial magnetic stimulation in the rat
Luft, A. R., Kaelin‐Lang, A., Hauser, T., Cohen, L. G., Thakor, N. V., & Hanley, D. F. (2001) · Experimental Brain Research · doi:10.1007/s002210100805 · Cited by 99
Noguchi, Y., Takeuchi, T., & Sakai, K. L. (2002) · Human Brain Mapping · doi:10.1002/hbm.10050 · Cited by 96
Intense Ultrasound in Investigations of the Central Nervous System
Fry, W. J. (1959) · Advances in biological and medical physics · doi:10.1016/b978-1-4832-3112-9.50012-8 · Cited by 85
Mechanisms of Electrical Stimulation with Neural Prostheses
Rattay, F., Resatz, S., Lutter, P., Minassian, K., Jilge, B., & Dimitrijevic, M. R. (2003) · Neuromodulation Technology at the Neural Interface · doi:10.1046/j.1525-1403.2003.03006.x · Cited by 84
Toward Establishing a Therapeutic Window for rTMS by Theta Burst Stimulation
Paulus, W. (2005) · Neuron · doi:10.1016/j.neuron.2005.01.008 · Cited by 83
On the synchronization of transcranial magnetic stimulation and functional echo‐planar imaging
Bestmann, S., Baudewig, J., & Frahm, J. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10260 · Cited by 83
Wagner, T., Gangitano, M., Romero, R., Théoret, H., Kobayashi, M., Anschel, D., Ives, J., Cuffin, N., Schomer, D., & Pascual-Leone, A. (2004) · Neuroscience Letters · doi:10.1016/s0304-3940(03)00861-9 · Cited by 78
Self-citationKuroda, Y., Motohashi, N., Ito, H., Ito, S., Takano, A., Nishikawa, T., & Suhara, T. (2006) · Journal of Affective Disorders · doi:10.1016/j.jad.2006.03.029 · Cited by 77
Electroencephalographic recording during transcranial magnetic stimulation in humans and animals
Ives, J. R., Rotenberg, A., Poma, R., Thut, G., & Pascual‐Leone, Á. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.04.010 · Cited by 76
Aydın-Abidin, S., Moliadze, V., Eysel, U. T., & Funke, K. (2006) · The Journal of Physiology · doi:10.1113/jphysiol.2006.108464 · Cited by 75
Moliadze, V., Giannikopoulos, D. V., Eysel, U. T., & Funke, K. (2005) · The Journal of Physiology · doi:10.1113/jphysiol.2005.086090 · Cited by 69
Long‐term effect of motor cortical repetitive transcranial magnetic stimulation induces
Hayashi, T., Ohnishi, T., Okabe, S., Teramoto, N., Nonaka, Y., Watabe, H., Imabayashi, E., Ohta, Y., Jino, H., Ejima, N., et al. (2004) · Annals of Neurology · doi:10.1002/ana.20151 · Cited by 68
Kim, D.-H., Georghiou, G. E., & Won, C. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.870244 · Cited by 68
Okabe, S., Hanajima, R., Ohnishi, T., Nishikawa, M., Imabayashi, E., Takano, H., Kawachi, T., Matsuda, H., Shiio, Y., Iwata, N. K., et al. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00408-x · Cited by 66
A generalized cable equation for magnetic stimulation of axons
Nagarajan, S. S., & Durand, D. M. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.486288 · Cited by 60
Levkovitz, Y., Marx, J., Grisaru, N., & Segal, M. (1999) · Journal of Neuroscience · doi:10.1523/jneurosci.19-08-03198.1999 · Cited by 59
Chouinard, P. A., Leonard, G. T., & Paus, T. (2006) · Experimental Neurology · doi:10.1016/j.expneurol.2006.04.037 · Cited by 58
Suppressing the Surface Field During Transcranial Magnetic Stimulation
Davey, K. R., & Riehl, M. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.862545 · Cited by 58
Yunokuchi, K., & Cohen, D. (1991) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199101000-00014 · Cited by 57
A 3-D differential coil design for localized magnetic stimulation
Hsu, K.-H., & Durand, D. M. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.951519 · Cited by 56
Focal magnetic stimulation of an axon
Basser, P. J. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.293248 · Cited by 56
Noguchi, Y., Watanabe, E., & Sakai, K. L. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00054-5 · Cited by 53
An accurate 3-D model for magnetic stimulation of the brain cortex
Cerri, G., De Leo, R., Moglie, F., & Schiavoni, A. (1995) · Journal of Medical Engineering & Technology · doi:10.3109/03091909509030264 · Cited by 51
A model of magnetic stimulation of neocortical neurons
Kamitani, Y., Bhalodia, V. M., Kubota, Y., & Shimojo, S. (2001) · Neurocomputing · doi:10.1016/s0925-2312(01)00447-7 · Cited by 51
Valero-Cabré, A., Rushmore, R. J., & Payne, B. R. (2006) · Experimental Brain Research · doi:10.1007/s00221-005-0307-4 · Cited by 48
Self-citationAnalysis of the distribution of currents induced by a changing magnetic field in a volume conductor
Branston, N. M., & Tofts, P. S. (1991) · Physics in Medicine and Biology · doi:10.1088/0031-9155/36/2/001 · Cited by 47
Baudewig, J., Paulus, W., & Frahm, J. (2000) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(00)00122-3 · Cited by 47
Hada, Y., Abo, M., Kaminaga, T., & Mikami, M. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.04.200 · Cited by 42
Designing transcranial magnetic stimulation systems
DAVEY, K. R., & Riehl, M. (2005) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2004.843326 · Cited by 40
Husain, F. T., Nandipati, G., Braun, A., Cohen, L. G., Tagamets, M.-A., & Horwitz, B. (2002) · NeuroImage · doi:10.1006/nimg.2001.0966 · Cited by 37
333. Intracerebral measurement of rTMS and ECS induced voltage in vivo
Lisanby, S. H., Luber, B., Schroeder, C., Osman, M., Finck, D., Jalinous, R., Amassian, V. E., Arezzo, J. C., & Sackeïm, H. A. (1998) · Biological Psychiatry · doi:10.1016/s0006-3223(98)90781-8 · Cited by 35
Repetitive high magnetic field stimulation: the effect upon rat brain.
Ja, S., Nr, G., Stanton, P. C., Emerson, R. G., & Blair, R. (1991) · PubMed · Cited by 35
Liu, R., & Ueno, S. (2000) · IEEE Transactions on Magnetics · doi:10.1109/20.877792 · Cited by 32
Computer modelling of brain cortex excitation by magnetic field pulses
Leo, R. D., Cerri, G., Balducci, D., Moglie, F., Scarpino, O., & Guidi, M. (1992) · Journal of Medical Engineering & Technology · doi:10.3109/03091909209030218 · Cited by 21
Toroidal coil models for transcutaneous magnetic simulation of nerves
Carbunaru, R., & Durand, D. M. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.915709 · Cited by 21
Magnetic shielding requirements for PET detectors during transcranial magnetic stimulation
Thompson, C. J., Paus, T., & Clancy, R. L. (1998) · IEEE Transactions on Nuclear Science · doi:10.1109/23.682021 · Cited by 13
Bestmann, S., Baudewig, J., Siebner, H. R., Rothwell, J. C., & Frahm, J. (2003) · Supplements to Clinical neurophysiology · doi:10.1016/s1567-424x(09)70209-0 · Cited by 10
Lee, J. S., Narayana, S., Lancaster, J. L., Jerabek, P., Lee, D. S., & Fox, P. T. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00239-8 · Cited by 9
Cited by
Rossi, S., Hallett, M., Rossini, P. M., & Pascual-Leone, A. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.08.016 · Cited by 5,367
“Several simulation models have been developed to provide a view of the electromagnetic field distributions generated in biological tissue during TMS (Wagner et al., 2007).”
MethodRossini, P. M., Burke, D., Chen, R., Cohen, L. G., Daskalakis, Z., Di Iorio, R., Di Lazzaro, V., Ferreri, F., Fitzgerald, P. B., George, M. S., et al. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.02.001 · Cited by 2,753
Self-citationFox, M. D., Buckner, R. L., White, M. P., Greicius, M. D., & Pascual-Leone, A. (2012) · Biological Psychiatry · doi:10.1016/j.biopsych.2012.04.028 · Cited by 1,270
“ue (for reviews, see [1–3]).”
Harnessing neuroplasticity for clinical applications
Cramer, S. C., Sur, M., Dobkin, B. H., O'Brien, C., Sanger, T. D., Trojanowski, J. Q., Rumsey, J. M., Hicks, R., Cameron, J., Chen, D., et al. (2011) · Brain · doi:10.1093/brain/awr039 · Cited by 1,259
“Introduced in the mid-1980s, transcranial magnetic stimulation uses an extracranial magnetic coil to induce current in the cerebral cortex (Wagner et al., 2007).”
InfluentialTranscranial Pulsed Ultrasound Stimulates Intact Brain Circuits
Tufail, Y., Matyushov, A., Baldwin, N., Tauchmann, M. L., Georges, J., Yoshihiro, A., Tillery, S. I. H., & Tyler, W. J. (2010) · Neuron · doi:10.1016/j.neuron.2010.05.008 · Cited by 977
Metadata
- Authors
- Wagner, T., Valero-Cabre, A., & Pascual-Leone, A.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2007-08-15
- Volume
- 9
- Issue
- 1
- Pages
- 527-565
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2087813588
- Cited by
- 873
- References
- 116
- FWCI
- 2.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.