Strategies for CT Radiation Dose Optimization
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Recent technologic advances have markedly enhanced the clinical applications of computed tomography (CT). While the benefits of CT exceed the harmful effects of radiation exposure in patients, increasing radiation doses to the population have raised a compelling case for reduction of radiation exposure from CT. Strategies for radiation dose reduction are difficult to devise, however, because of a lack of guidelines regarding CT examination and scanning techniques. Various methods and strategies based on individual patient attributes and CT technology have been explored for dose optimization. It is the purpose of this review article to outline basic principles of CT radiation exposure and emphasize the need for CT radiation dose optimization based on modification of scanning parameters and application of recent technologic innovations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222
The United Nations Scientific Committee on the Effects of Atomic Radiation
(1965) · Nature · doi:10.1038/206014c0 · Cited by 1,636
CT scanning: patterns of use and dose
Mettler, F. A., Wiest, P. W., Locken, J. A., & Kelsey, C. A. (2000) · Journal of Radiological Protection · doi:10.1088/0952-4746/20/4/301 · Cited by 664
AAPM/RSNA Physics Tutorial for Residents: Topics in CT: Radiation Dose in CT
McNitt-Gray, M. F. (2002) · RadioGraphics · doi:10.1148/rg.226025128 · Cited by 612
Donnelly, L. F., Emery, K. H., Brody, A. S., Laor, T., Gylys-Morin, V. M., Anton, C. G., Thomas, S. R., & Frush, D. P. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760303 · Cited by 480
Lessons we have learned from our children: cancer risks from diagnostic radiology
Hall, E. J. (2002) · Pediatric Radiology · doi:10.1007/s00247-002-0774-8 · Cited by 415
Performance evaluation of a multi-slice CT system
McCollough, C. H., & Zink, F. E. (1999) · Medical Physics · doi:10.1118/1.598777 · Cited by 386
Managing patient dose in computed tomography
(2000) · Annals of the ICRP · doi:10.1016/s0146-6453(01)00049-5 · Cited by 375
Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements
Kalender, W. A., Wolf, H., & Suess, C. (1999) · Medical Physics · doi:10.1118/1.598738 · Cited by 345
Cited by
MacMahon, H., Austin, J. H. M., Gamsu, G., Herold, C. J., Jett, J. R., Naidich, D. P., Patz, E. F., & Swensen, S. J. (2005) · Radiology · doi:10.1148/radiol.2372041887 · Cited by 1,574
Sodickson, A., Baeyens, P. F., Andriole, K. P., Prevedello, L. M., Nawfel, R. D., Hanson, R., & Khorasani, R. (2009) · Radiology · doi:10.1148/radiol.2511081296 · Cited by 990
Strategies for Reducing Radiation Dose in CT
McCollough, C. H., Primak, A. N., Braun, N., Kofler, J., Yu, L., & Christner, J. (2009) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2008.10.006 · Cited by 842
CT Dose Reduction and Dose Management Tools: Overview of Available Options
McCollough, C. H., Bruesewitz, M. R., & Kofler, J. M. (2006) · RadioGraphics · doi:10.1148/rg.262055138 · Cited by 768
Techniques and Applications of Automatic Tube Current Modulation for CT
Kalra, M. K., Maher, M. M., Toth, T. L., Schmidt, B., Westerman, B. L., Morgan, H. T., & Saini, S. (2004) · Radiology · doi:10.1148/radiol.2333031150 · Cited by 725
Self-citationLung ultrasound in the critically ill
Lichtenstein, D. A. (2014) · Annals of Intensive Care · doi:10.1186/2110-5820-4-1 · Cited by 711
Radiation Risk to Children From Computed Tomography
Brody, A. S., Frush, D. P., Huda, W., Brent, R. L., & Radiology, A. T. S. O. (2007) · Pediatrics · doi:10.1542/peds.2007-1910 · Cited by 606
The Measurement, Reporting, and Management of Radiation Dose in CT
McCollough, C., Cody, D., Edyvean, S., Geise, R., Gould, B., Keat, N., Huda, W., Judy, P., Kalender, W., McNitt-Gray, M., et al. (2008) · doi:10.37206/97 · Cited by 569
National survey of doses from CT in the UK: 2003
Shrimpton, P. C., Hillier, M. C., Lewis, M. A., & Dunn, M. (2006) · The British Journal of Radiology · doi:10.1259/bjr/93277434 · Cited by 568
Increasing utilization of computed tomography in the adult emergency department, 2000–2005
Broder, J., & Warshauer, D. M. (2006) · Emergency Radiology · doi:10.1007/s10140-006-0493-9 · Cited by 478
You, C., Cong, W., Vannier, M. W., Saha, P. K., Hoffman, E. A., Wang, G., Li, G., Zhang, Y., Zhang, X., Shan, H., et al. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2922960 · Cited by 459
A Sparse-View CT Reconstruction Method Based on Combination of DenseNet and Deconvolution
Zhang, Z., Liang, X., Dong, X., Xie, Y., & Cao, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2823338 · Cited by 447
Mulkens, T. H., Bellinck, P., Baeyaert, M., Ghysen, D., Van Dijck, X., Mussen, E., Venstermans, C., & Termote, J.-L. (2005) · Radiology · doi:10.1148/radiol.2363041220 · Cited by 354
Singh, S., Kalra, M. K., Gilman, M. D., Hsieh, J., Pien, H. H., Digumarthy, S. R., & Shepard, J.-A. O. (2011) · Radiology · doi:10.1148/radiol.11101450 · Cited by 344
Self-citationComputed tomography and patient risk: Facts, perceptions and uncertainties
Power, S. P., Moloney, F., Twomey, M., James, K., O’Connor, O. J., & Maher, M. M. (2016) · World Journal of Radiology · doi:10.4329/wjr.v8.i12.902 · Cited by 335
Self-citationArtifact Suppressed Dictionary Learning for Low-Dose CT Image Processing
Chen, Y., Shi, L., Feng, Q., Yang, J., Shu, H., Luo, L., Coatrieux, J.-L., & Chen, W. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2336860 · Cited by 315
Ultrasound in the management of thoracic disease
Lichtenstein, D. A. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000260674.60761.85 · Cited by 307
120 Crohn's Disease: Factors Associated with Exposure to High Levels of Diagnostic Radiation
Desmond, A. N., O'Regan, K. N., Curran, C., McWilliams, S., Maher, M. M., & Shanahan, F. (2008) · Gastroenterology · doi:10.1016/s0016-5085(08)60102-x · Cited by 307
Self-citationStrauss, K. J., Goske, M. J., Kaste, S. C., Bulas, D., Frush, D. P., Butler, P., Morrison, G., Callahan, M. J., & Applegate, K. E. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.4091 · Cited by 305
Siegel, M. J., Schmidt, B., Bradley, D., Suess, C., & Hildebolt, C. (2004) · Radiology · doi:10.1148/radiol.2332032107 · Cited by 294
Katsura, M., Matsuda, I., Akahane, M., Sato, J., Akai, H., Yasaka, K., Kunimatsu, A., & Ohtomo, K. (2012) · European Radiology · doi:10.1007/s00330-012-2452-z · Cited by 278
CT Radiation Dose Optimization and Estimation: an Update for Radiologists
Goo, H. W. (2012) · Korean Journal of Radiology · doi:10.3348/kjr.2012.13.1.1 · Cited by 252
“In conjunction with the increasing concerns about potential CT radiation hazards, various CT dose-saving strategies have been developed (8, 9).”
BackgroundMa, J., Huang, J., Feng, Q., Zhang, H., Lu, H., Liang, Z., & Chen, W. (2011) · Medical Physics · doi:10.1118/1.3638125 · Cited by 249
Iterative Low-Dose CT Reconstruction With Priors Trained by Artificial Neural Network
Wu, D., Kim, K., El Fakhri, G., & Li, Q. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2753138 · Cited by 244
“The most practical way is to reduce the X-ray tube current, but the reduction of photon flux causes increased noises and artifacts in the reconstructed images, which jeopardize the accuracy of diagnoses [1].”
BackgroundSöderberg, M., & Gunnarsson, M. (2010) · Acta Radiologica · doi:10.3109/02841851003698206 · Cited by 239
Semelka, R. C., Armao, D. M., Elias, J., & Huda, W. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20895 · Cited by 238
Pontana, F., Duhamel, A., Pagniez, J., Flohr, T., Faivre, J.-B., Hachulla, A.-L., Remy, J., & Remy-Jardin, M. (2011) · European Radiology · doi:10.1007/s00330-010-1991-4 · Cited by 230
“A further step in the dose saving direction was the acceptance that diagnostic images could tolerate a certain amount of noise, as reported for screening purposes or follow-up examinations of benign diseases [7, 8].”
BackgroundImproving abdomen tumor low-dose CT images using a fast dictionary learning based processing
Chen, Y., Yin, X., Shi, L., Shu, H., Luo, L., Coatrieux, J.-L., & Toumoulin, C. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/16/5803 · Cited by 223
Yeh, B. M., FitzGerald, P. F., Edic, P. M., Lambert, J. W., Colborn, R. E., Marino, M. E., Evans, P. M., Roberts, J. C., Wang, Z. J., Wong, M. J., et al. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.09.001 · Cited by 219
Automatic Patient Centering for MDCT: Effect on Radiation Dose
Li, J., Udayasankar, U. K., Toth, T. L., Seamans, J., Small, W. C., & Kalra, M. K. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.0370 · Cited by 206
“CTDIvol is a principal descriptor of average absorbed dose for CT [1] and is measured in milligrays.”
BackgroundSelf-citationUnsupervised MR-to-CT Synthesis Using Structure-Constrained CycleGAN
Yang, H., Sun, J., Carass, A., Zhao, C., Lee, J., Prince, J. L., & Xu, Z. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.3015379 · Cited by 204
“in RTP, it would avoid these difficulties and also prevent the potential harmful effects of radiation exposure [4].”
BackgroundComputed Tomography: Revolutionizing the Practice of Medicine for 40 Years
Rubin, G. D. (2014) · Radiology · doi:10.1148/radiol.14141356 · Cited by 197
Prakash, P., Kalra, M. K., Digumarthy, S. R., Hsieh, J., Pien, H., Singh, S., Gilman, M. D., & Shepard, J.-A. O. (2010) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0b013e3181b26c67 · Cited by 188
Self-citationEstablishment of CT diagnostic reference levels in Ireland
Foley, S. J., McEntee, M. F., & Rainford, L. A. (2012) · The British Journal of Radiology · doi:10.1259/bjr/15839549 · Cited by 186
A review of patient dose and optimisation methods in adult and paediatric CT scanning
Dougeni, E., Faulkner, K., & Panayiotakis, G. (2012) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.05.025 · Cited by 185
Kalra, M. K., Maher, M. M., Toth, T. L., Kamath, R. S., Halpern, E. F., & Saini, S. (2004) · Radiology · doi:10.1148/radiol.2322031304 · Cited by 180
Self-citationComparison of Different Body Size Parameters for Individual Dose Adaptation in Body CT of Adults
Menke, J. (2005) · Radiology · doi:10.1148/radiol.2362041327 · Cited by 164
Lung Ultrasound in the Critically Ill Neonate
A. Lichtenstein, D., & Mauriat, P. (2012) · Current Pediatric Reviews · doi:10.2174/157339612802139389 · Cited by 162
Rizzo, S. M. R., Kalra, M. K., Schmidt, B., Raupach, R., Maher, M. M., Blake, M. A., & Saini, S. (2005) · Radiology · doi:10.1148/radiol.2371041879 · Cited by 51
Self-citationOglat, A., Shdaifat, S., Sayah, M., Abukonna, A., & Khogali, W. (2026) · Drug, Healthcare and Patient Safety · doi:10.2147/dhps.s595721
“20,21 Computed tomography is extensively utilized in the thorax to assess pulmonary embolism, pulmonary infections, and for oncological staging.”
Metadata
- Authors
- Kalra, M. K., Maher, M. M., Toth, T. L., Hamberg, L. M., Blake, M. A., Shepard, J.-A., & Saini, S.
- Venue
- Radiology
- Published
- 2004-03
- Volume
- 230
- Issue
- 3
- Pages
- 619-628
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2001435563
- Cited by
- 1,080
- References
- 36
- FWCI
- 32.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.