The DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
Electrical Stimulation of Mammalian Retinal Ganglion Cells With Multielectrode Arrays
Abstract
Existing epiretinal implants for the blind are designed to electrically stimulate large groups of surviving retinal neurons using a small number of electrodes with diameters of several hundred micrometers. To increase the spatial resolution of artificial sight, electrodes much smaller than those currently in use are desirable. In this study, we stimulated and recorded ganglion cells in isolated pieces of rat, guinea pig, and monkey retina. We used microfabricated hexagonal arrays of 61 platinum disk electrodes with diameters between 6 and 25 μm, spaced 60 μm apart. Charge-balanced current pulses evoked one or two spikes at latencies as short as 0.2 ms, and typically only one or a few recorded ganglion cells were stimulated. Application of several synaptic blockers did not abolish the evoked responses, implying direct activation of ganglion cells. Threshold charge densities were typically <0.1 mC/cm 2 for a pulse duration of 100 μs, corresponding to charge thresholds of <100 pC. Stimulation remained effective after several hours and at high frequencies. To show that closely spaced electrodes can elicit independent ganglion cell responses, we used the multielectrode array to stimulate several nearby ganglion cells simultaneously. From these data, we conclude that electrical stimulation of mammalian retina with small-diameter electrode arrays is achievable and can provide high temporal and spatial precision at low charge densities. We review previous epiretinal stimulation studies and discuss our results in the context of 32 other publications, comparing threshold parameters and safety limits.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Which elements are excited in electrical stimulation of mammalian central nervous system: A review
Ranck, J. B. (1975) · Brain Research · doi:10.1016/0006-8993(75)90364-9 · Cited by 2,024
The Five-year Incidence and Progression of Age-related Maculopathy
Klein, R., Klein, B. E. K., Jensen, S. C., & Meuer, S. M. (1997) · Ophthalmology · doi:10.1016/s0161-6420(97)30368-6 · Cited by 1,135
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708
Preservation of the Inner Retina in Retinitis Pigmentosa: A Morphometric Analysis
Santos, A. (1997) · Archives of Ophthalmology · doi:10.1001/archopht.1997.01100150513011 · Cited by 643
Visual Perception Elicited by Electrical Stimulation of Retina in Blind Humans
Humayun, M. S. (1996) · Archives of Ophthalmology · doi:10.1001/archopht.1996.01100130038006 · Cited by 601
Pattern electrical stimulation of the human retina
Humayun, M. S., de Juan Jr., E., Weiland, J. D., Dagnelie, G., Katona, S., Greenberg, R., & Suzuki, S. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00052-8 · Cited by 592
A model of safe levels for electrical stimulation
Shannon, R. V. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.126616 · Cited by 526
Axons, but not cell bodies, are activated by electrical stimulation in cortical gray matter
Nowak, L. G., & Bullier, J. (1998) · Experimental Brain Research · doi:10.1007/s002210050304 · Cited by 492
(2007) · doi:10.1007/978-0-387-48865-3 · Cited by 483
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478
Electrical stimulation of neural tissue to evoke behavioral responses
Tehovnik, E. J. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00131-x · Cited by 478
Stone, J. L. (1992) · Archives of Ophthalmology · doi:10.1001/archopht.1992.01080230134038 · Cited by 467
Multi-neuronal signals from the retina: acquisition and analysis
Meister, M., Pine, J., & Baylor, D. A. (1994) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(94)90030-2 · Cited by 411
In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
Weiland, J. D., Anderson, D. J., & Humayun, M. S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805487 · Cited by 382
Rose, T. L., & Robblee, L. S. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.61038 · Cited by 358
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0819 · Cited by 358
Determination of antidromic excitation by the collision test: Problems of interpretation
Fuller, J. H., & Schlag, J. D. (1976) · Brain Research · doi:10.1016/0006-8993(76)90284-5 · Cited by 341
Excitation of Central Nervous System Neurons by Nonuniform Electric Fields
McIntyre, C. C., & Grill, W. M. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77251-6 · Cited by 319
Mosaic Arrangement of Ganglion Cell Receptive Fields in Rabbit Retina
Devries, S. H., & Baylor, D. A. (1997) · Journal of Neurophysiology · doi:10.1152/jn.1997.78.4.2048 · Cited by 313
Functional specialization of the axon initial segment by isoform-specific sodium channel targeting
Boiko, T., Van Wart, A., Caldwell, J. H., Levinson, S. R., Trimmer, J. S., & Matthews, G. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-06-02306.2003 · Cited by 311
Shackleton, R. G. (2005) · Cited by 294
Can subretinal microphotodiodes successfully replace degenerated photoreceptors?
Zrenner, E., Stett, A., Weiss, S., Aramant, R. B., Guenther, E., Kohler, K., Miliczek, K.-D., Seiler, M. J., & Haemmerle, H. (1999) · Vision Research · doi:10.1016/s0042-6989(98)00312-5 · Cited by 290
Electrical multisite stimulation of the isolated chicken retina
Stett, A., Barth, W., Weiss, S., Haemmerle, H., & Zrenner, E. (2000) · Vision Research · doi:10.1016/s0042-6989(00)00005-5 · Cited by 259
Selective Microstimulation of Central Nervous System Neurons
McIntyre, C. C., & Grill, W. M. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.262 · Cited by 258
Real-time multi-channel stimulus artifact suppression by local curve fitting
Wagenaar, D. A., & Potter, S. M. (2002) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00149-8 · Cited by 227
Mobility performance with a pixelized vision system.
Cha, K., Horch, K. W., & Normann, R. A. (1992) · Vision Research · doi:10.1016/0042-6989(92)90229-c · Cited by 226
Beebe, X., & Rose, T. L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.2122 · Cited by 219
Brummer, S. B., & Turner, M. J. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326179 · Cited by 216
Brummer, S. B., Robblee, L. S., & Hambrecht, F. T. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31628.x · Cited by 205
Simulation of a phosphene-based visual field: Visual acuity in a pixelized vision system
Cha, K., Horch, K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368135 · Cited by 198
Ritchie, J. M., Rogart, R. B., & Strichartz, G. R. (1976) · The Journal of Physiology · doi:10.1113/jphysiol.1976.sp011569 · Cited by 195
A computational model of electrical stimulation of the retinal ganglion cell
Greenberg, R. J., Velte, T. J., Humayun, M. S., Scarlatis, G. N., & De Juan, E. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.759051 · Cited by 184
Multi-electrode stimulation and recording in the isolated retina
Grumet, A. E., Wyatt, J. L., & Rizzo, J. F. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00246-6 · Cited by 167
Jensen, R. J., Ziv, O. R., & Rizzo, J. F. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-1018 · Cited by 159
MORPHOMETRIC ANALYSIS OF THE MACULA IN EYES WITH DISCIFORM AGE-RELATED MACULAR DEGENERATION
KIM, S. Y., SADDA, S., PEARLMAN, J., HUMAYUN, M. S., de JUAN, E., MELIA, B. M., & GREEN, W. R. (2002) · Retina · doi:10.1097/00006982-200208000-00012 · Cited by 158 · cited 1×
“While degenerative diseases result in severe damage to photoreceptors, inner retinal neurons survive at fairly high rates (Stone et al. 1992; Santos et al. 1997; Kim et al. 2002) and may be electrically excitable.”
BackgroundLocalization of sodium channels in axon hillocks and initial segments of retinal ganglion cells.
Wollner, D. A., & Catterall, W. A. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.21.8424 · Cited by 158
Bipolar Surface Electrical Stimulation of the Vertebrate Retina
Humayun, M. (1994) · Archives of Ophthalmology · doi:10.1001/archopht.1994.01090130120028 · Cited by 158
Jensen, R. J., Rizzo, J. F., Ziv, O. R., Grumet, A., & Wyatt, J. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-1041 · Cited by 145
Identification of the target neuronal elements in electrical deep brain stimulation
Holsheimer, J., Demeulemeester, H. G., Nuttin, B., & de Sutter, P. (2000) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2000.01306.x · Cited by 130
Receptive-field microstructure of blue-yellow ganglion cells in primate retina
Chichilnisky, E. J., & Baylor, D. A. (1999) · Nature Neuroscience · doi:10.1038/13189 · Cited by 126
Self-citationSteady discharges of X and Y retinal ganglion cells of cat under photopic illuminance
Troy, J. B., & Robson, J. G. (1992) · Visual Neuroscience · doi:10.1017/s0952523800001784 · Cited by 115
REVIEW ■ : Prospects for a Visual Prosthesis
Rizzo, J. F., & Wyatt, J. L. (1997) · The Neuroscientist · doi:10.1177/107385849700300413 · Cited by 114
Responses of rabbit retinal ganglion cells to electrical stimulation with an epiretinal electrode
Jensen, R. J., Ziv, O. R., & Rizzo, J. F. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/003 · Cited by 111
Mechanisms by Which Cell Geometry Controls Repetitive Impulse Firing in Retinal Ganglion Cells
Fohlmeister, J. F., & Miller, R. F. (1997) · Journal of Neurophysiology · doi:10.1152/jn.1997.78.4.1948 · Cited by 101
Hesse, L., Schanze, T., Wilms, M., & Eger, M. (2000) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s004170000197 · Cited by 98
Understanding the origin of visual percepts elicited by electrical stimulation of the human retina
Weiland, J. D., Humayun, M. S., Dagnelie, G., de Juan, E., Greenberg, R. J., & Iliff, N. T. (1999) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s004170050337 · Cited by 90
RETINAL EXCITATION AND INHIBITION FROM DIRECT ELECTRICAL STIMULATION
Crapper, D. R., & Noell, W. K. (1963) · Journal of Neurophysiology · doi:10.1152/jn.1963.26.6.924 · Cited by 88
Subretinal electrical stimulation of the rabbit retina with acutely implanted electrode arrays
Gekeler, F., Kobuch, K. A., Schwahn, H., Stett, A., Shinoda, K., & Zrenner, E. (2004) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-004-0862-6 · Cited by 82
Evoked cortical potentials after electrical stimulation of the inner retina in rabbits
Walter, P., & Heimann, K. (2000) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s004170050358 · Cited by 81
Neuronal activity evoked by chronically implanted intracortical microelectrodes
McCreery, D. B., Bullara, L. A., & Agnew, W. F. (1986) · Experimental Neurology · doi:10.1016/0014-4886(86)90131-7 · Cited by 75
Nadig, M. N. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00027-9 · Cited by 66
The electrical stimulation of the retina by indwelling electrodes.
Dawson, W. W., & Radtke, N. D. (1977) · PubMed · Cited by 63
Comparison of Electrical Stimulation Thresholds in Normal and Retinal Degenerated Mouse Retina
Suzuki, S., Humayun, M. S., Weiland, J. D., Chen, S., Margalit, E., Piyathaisere, D. V., & de Juan, E. (2004) · Japanese Journal of Ophthalmology · doi:10.1007/s10384-004-0084-9 · Cited by 60
BIOPHYSICAL CONSIDERATIONS IN ELECTRICAL STIMULATION OF THE AUDITORY NERVOUS SYSTEMa
Loeb, G. E., White, M. W., & Jenkins, W. M. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31625.x · Cited by 54
Responses of Single Neurons to Electrical Stimulation of the Surface of the Visual Cortex
Pollen, D. A. (2008) · Brain Behavior and Evolution · doi:10.1159/000125576 · Cited by 53
Activation zones in cat visual cortex evoked by electrical retina stimulation
Schanze, T., Wilms, M., Eger, M., Hesse, L., & Eckhorn, R. (2002) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-002-0577-5 · Cited by 51
Large-area microelectrode arrays for recording of neural signals
Mathieson, K., Kachiguine, S., Adams, C., et al. (2004) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2004.835873 · Cited by 47
Electrical stimulation of isolated retina with microwire glass electrodes
Johnson, L., Perkins, F. K., O’Hearn, T. M., Skeath, P. R., Merritt, C. D., Frieble, J., Sadda, S. R., Humayun, M. S., & Scribner, D. A. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.02.035 · Cited by 42
Enzyme sensors prepared by electrodeposition on platinized platinum electrodes
Kim, C. S., & Oh, S. M. (1996) · Electrochimica Acta · doi:10.1016/0013-4686(96)00030-8 · Cited by 41
Shimazu, K., Miyake, Y., & Watanabe, S. (1999) · Vision Research · doi:10.1016/s0042-6989(98)00331-9 · Cited by 40
Wilms, M., Eger, M., Schanze, T., & ECKHORNdagger, R. (2003) · Visual Neuroscience · doi:10.1017/s0952523803205083 · Cited by 40
Focal stimulation of hypoglossal neurones in the cat
Porter, R. W. (1963) · The Journal of Physiology · doi:10.1113/jphysiol.1963.sp007285 · Cited by 39
Laube, T., Schanze, T., Brockmann, C., Bolle, I., Stieglitz, T., & Bornfeld, N. (2003) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-003-0758-x · Cited by 31
Attracting retinal cells to electrodes for high-resolution stimulation
Palanker, D., Huie, P., Vankov, A., Freyvert, Y., Fishman, H. A., Marmor, M. F., & Blumenkranz, M. S. (2004) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.529757 · Cited by 27
Electric stimulation parameters for an epi-retinal prosthesis
Grumet, A. (1999) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 25
Kuras, A., Baginskas, A., & Batulevičienė, V. (2004) · Experimental Brain Research · doi:10.1007/s00221-004-1976-0 · Cited by 19
The retinal readout system: an application of microstrip detector technology to neurobiology
Litke, A. M. (1998) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/s0168-9002(98)00734-7 · Cited by 19
Self-citationThe Retinal Readout System: a status report
Litke, A. M. (1999) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/s0168-9002(99)00445-3 · Cited by 16
Self-citationDevelopment of front-end ASICs for imaging neuronal activity in live tissue
Dąbrowski, W., Gryboś, P., Hottowy, P., et al. (2005) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2005.01.082 · Cited by 15
Self-citationSekirnjak, C., Hottowy, P., Sher, A., Dąbrowski, W., Litke, A. M., & Chichilnisky, E. J. (2007) · Springer eBooks · doi:10.1007/978-0-387-49331-2_18 · Cited by 6
Self-citation
Cited by
Direct and Indirect Activation of Cortical Neurons by Electrical Microstimulation
Tehovnik, E. J., Tolias, A. S., Sultan, F., Slocum, W. M., & Logothetis, N. K. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00126.2006 · Cited by 357
The Argus® II Retinal Prosthesis System
Luo, Y. H.-L., & da Cruz, L. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.09.003 · Cited by 351
Cell-Based Biosensors and Their Application in Biomedicine
Liu, Q., Wu, C., Cai, H., Hu, N., Zhou, J., & Wang, P. (2014) · Chemical Reviews · doi:10.1021/cr2003129 · Cited by 348
Retinal stimulation strategies to restore vision: fundamentals and systems
Yue, L., Weiland, J. D., Roska, B., & Humayun, M. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.05.002 · Cited by 272
Factors affecting perceptual thresholds in epiretinal prostheses
de Balthasar, C., Patel, S., Roy, A., Freda, R., Greenwald, S., Horsager, A., Mahadevappa, M., Yanai, D., McMahon, M. J., Humayun, M. S., et al. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-0696 · Cited by 204
Metadata
- Authors
- Sekirnjak, C., Hottowy, P., Sher, A., Dabrowski, W., Litke, A. M., & Chichilnisky, E. J.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 2006-06
- Volume
- 95
- Issue
- 6
- Pages
- 3311-3327
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2016971620
- Cited by
- 337
- References
- 72
- FWCI
- 5.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.