The DOI matches its Crossref record; 200 of the 200 references it cites were found in a registry or an index.
Computer-Aided Diagnosis Systems for Lung Cancer: Challenges and Methodologies
Open accessAbstract
This paper overviews one of the most important, interesting, and challenging problems in oncology, the problem of lung cancer diagnosis. Developing an effective computer-aided diagnosis(CAD) system for lung cancer is of great clinical importance and can increase the patient’s chance of survival. For this reason, CAD systems for lung cancer have been investigated in a huge number of research studies. A typical CAD system for lung cancer diagnosis is composed of four main processing steps: segmentation of the lung fields, detection of nodules inside the lung fields, segmentation of the detected nodules, and diagnosis of the nodules as benign or malignant. This paper overviews the current state-of-the-art techniques that have been developed to implement each of these CAD processing steps. For each technique, various aspects of technical issues, implemented methodologies, training and testing databases, and validation methods, as well as achieved performances, are described. In addition, the paper addresses several challenges that researchers face in each implementation step and outlines the strengths and drawbacks of the existing approaches for lung cancer CAD systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Threshold Selection Method from Gray-Level Histograms
Otsu, N. (1979) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1979.4310076 · Cited by 43,398
The Nature of Statistical Learning Theory
Vapnik, V. N. (1995) · doi:10.1007/978-1-4757-2440-0 · Cited by 39,138
Learning representations by back-propagating errors
Rumelhart, D. E., Hinton, G. E., & Williams, R. J. (1986) · Nature · doi:10.1038/323533a0 · Cited by 31,892
Wu, Y. (1999) · Technometrics · doi:10.1080/00401706.1999.10485951 · Cited by 27,221
Classification and Regression Trees.
Gordon, A. D., Breiman, L., Friedman, J. H., Olshen, R. A., & Stone, C. J. (1984) · Biometrics · doi:10.2307/2530946 · Cited by 23,522
(2012) · Encyclopedia of the Sciences of Learning · doi:10.1007/978-1-4419-1428-6_5195 · Cited by 19,370
Kass, M., Witkin, A., & Terzopoulos, D. (1988) · International Journal of Computer Vision · doi:10.1007/bf00133570 · Cited by 17,070
Learning Internal Representations by Error Propagation
Rumelhart, D. E., Hinton, G. E., & Williams, R. J. (1985) · doi:10.21236/ada164453 · Cited by 16,172
Mean shift: a robust approach toward feature space analysis
Comaniciu, D., & Meer, P. (2002) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.1000236 · Cited by 11,305
Introduction to Statistical Pattern Recognition
(1990) · Elsevier eBooks · doi:10.1016/c2009-0-27872-x · Cited by 11,031
Chan, T. F., & Vese, L. A. (2001) · IEEE Transactions on Image Processing · doi:10.1109/83.902291 · Cited by 10,304
Hanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016
Fast approximate energy minimization via graph cuts
Boykov, Y., Veksler, O., & Zabih, R. (2001) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.969114 · Cited by 6,988
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Caselles, V., Kimmel, R., & Sapiro, G. (1997) · International Journal of Computer Vision · doi:10.1023/a:1007979827043 · Cited by 5,244
Divergence measures based on the Shannon entropy
Lin, J. (1991) · IEEE Transactions on Information Theory · doi:10.1109/18.61115 · Cited by 5,140
Parallel & distributed processing
Slusallek, P., Shirley, P., Mark, W., Stoll, G., & Wald, I. (2005) · ACM SIGGRAPH 2005 Courses on - SIGGRAPH '05 · doi:10.1145/1198555.1198750 · Cited by 2,568
Feature detection with automatic scale selection
Lindeberg, T. (1998) · International Journal of Computer Vision · doi:10.1023/a:1008045108935 · Cited by 2,541
Early Lung Cancer Action Project: overall design and findings from baseline screening
Henschke, C. I., McCauley, D. I., Yankelevitz, D. F., Naidich, D. P., McGuinness, G., Miettinen, O. S., Libby, D. M., Pasmantier, M. W., Koizumi, J., Altorki, N. K., et al. (1999) · The Lancet · doi:10.1016/s0140-6736(99)06093-6 · Cited by 2,508
A Multiphase Level Set Framework for Image Segmentation Using the Mumford and Shah Model
Vese, L. A., & Chan, T. F. (2002) · International Journal of Computer Vision · doi:10.1023/a:1020874308076 · Cited by 2,384
Current Methods in Medical Image Segmentation
Pham, D. L., Xu, C., & Prince, J. L. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.315 · Cited by 2,341
Kittler, J., & Illingworth, J. (1986) · Pattern Recognition · doi:10.1016/0031-3203(86)90030-0 · Cited by 2,180
ROC Methodology in Radiologic Imaging
METZ, C. E. (1986) · Investigative Radiology · doi:10.1097/00004424-198609000-00009 · Cited by 1,642
Lardinois, D., Weder, W., Hany, T. F., Kamel, E. M., Korom, S., Seifert, B., von Schulthess, G. K., & Steinert, H. C. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022136 · Cited by 1,416
Using dynamic programming for solving variational problems in vision
Amini, A. A., Weymouth, T. E., & Jain, R. C. (1990) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.57681 · Cited by 1,008
Automatic lung segmentation for accurate quantitation of volumetric X-ray CT images
Hu, S., Hoffman, E. A., & Reinhardt, J. M. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.929615 · Cited by 940
CT Screening for Lung Cancer: Frequency and Significance of Part-Solid and Nonsolid Nodules
Henschke, C. I., Yankelevitz, D. F., Mirtcheva, R., McGuinness, G., McCauley, D., & Miettinen, O. S. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.5.1781053 · Cited by 909
A shape-based approach to the segmentation of medical imagery using level sets
Tsai, A., Yezzi, A., Wells, W., Tempany, C., Tucker, D., Fan, A., Grimson, W. E., & Willsky, A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.808355 · Cited by 894
Peripheral lung cancer: screening and detection with low-dose spiral CT versus radiography.
Kaneko, M., Eguchi, K., Ohmatsu, H., Kakinuma, R., Naruke, T., Suemasu, K., & Moriyama, N. (1996) · Radiology · doi:10.1148/radiology.201.3.8939234 · Cited by 831
Lung Cancer Screening with CT: Mayo Clinic Experience
Swensen, S. J., Jett, J. R., Hartman, T. E., Midthun, D. E., Sloan, J. A., Sykes, A.-M., Aughenbaugh, G. L., & Clemens, M. A. (2003) · Radiology · doi:10.1148/radiol.2263020036 · Cited by 665
Optimal Surface Segmentation in Volumetric Images-A Graph-Theoretic Approach
Li, K., Wu, X., Chen, D. Z., & Sonka, M. (2006) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2006.19 · Cited by 664
(2005) · PubMed · Cited by 612
Small Pulmonary Nodules: Volumetrically Determined Growth Rates Based on CT Evaluation
Yankelevitz, D. F., Reeves, A. P., Kostis, W. J., Zhao, B., & Henschke, C. I. (2000) · Radiology · doi:10.1148/radiology.217.1.r00oc33251 · Cited by 579
Growth rate of small lung cancers detected on mass CT screening.
Hasegawa, M., Sone, S., Takashima, S., Li, F., Yang, Z. G., Maruyama, Y., & Watanabe, T. (2000) · The British Journal of Radiology · doi:10.1259/bjr.73.876.11205667 · Cited by 560
Impact of FDG-PET on radiation therapy volume delineation in non–small-cell lung cancer
Bradley, J., Thorstad, W. L., Mutic, S., Miller, T. R., Dehdashti, F., Siegel, B. A., Bosch, W., & Bertrand, R. J. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2003.10.044 · Cited by 556
Computer analysis of computed tomography scans of the lung: a survey
Sluimer, I., Schilham, A., Prokop, M., & van Ginneken, B. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.862753 · Cited by 556
Prospective investigation of positron emission tomography in lung nodules.
Lowe, V. J., Fletcher, J. W., Gobar, L., Lawson, M., Kirchner, P., Valk, P., Karis, J., Hubner, K., Delbeke, D., Heiberg, E. V., et al. (1998) · Journal of Clinical Oncology · doi:10.1200/jco.1998.16.3.1075 · Cited by 552
van Ginneken, B., Stegmann, M. B., & Loog, M. (2006) · Medical Image Analysis · doi:10.1016/j.media.2005.02.002 · Cited by 539
Computer-aided diagnosis in chest radiography: a survey
Van Ginneken, B., Ter Haar Romeny, B. M., & Viergever, M. A. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974918 · Cited by 516
Sone, S., Li, F., Yang, Z.-G., Honda, T., Maruyama, Y., Takashima, S., Hasegawa, M., Kawakami, S., Kubo, K., Haniuda, M., et al. (2001) · British Journal of Cancer · doi:10.1054/bjoc.2000.1531 · Cited by 495
Lee, Y., Hara, T., Fujita, H., Itoh, S., & Ishigaki, T. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.932744 · Cited by 457
A new computationally efficient CAD system for pulmonary nodule detection in CT imagery
Messay, T., Hardie, R. C., & Rogers, S. K. (2010) · Medical Image Analysis · doi:10.1016/j.media.2010.02.004 · Cited by 439
Dynamic programming for detecting, tracking, and matching deformable contours
Geiger, D., Gupta, A., Costa, L. A., & Vlontzos, J. (1995) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.368194 · Cited by 429
Sahiner, B., Chan, H.-P., Petrick, N., Wei, D., Helvie, M. A., Adler, D. D., & Goodsitt, M. M. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.538937 · Cited by 420
A gradient-based method for segmenting FDG-PET images: methodology and validation
Geets, X., Lee, J. A., Bol, A., Lonneux, M., & Grégoire, V. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0363-4 · Cited by 419
Using Prior Shapes in Geometric Active Contours in a Variational Framework
Chen, Y., Tagare, H. D., Thiruvenkadam, S., Huang, F., Wilson, D., Gopinath, K. S., Briggs, R. W., & Geiser, E. A. (2002) · International Journal of Computer Vision · doi:10.1023/a:1020878408985 · Cited by 406
Computerized Detection of Pulmonary Nodules on CT Scans
Armato, S. G., Giger, M. L., Moran, C. J., Blackburn, J. T., Doi, K., & MacMahon, H. (1999) · Radiographics · doi:10.1148/radiographics.19.5.g99se181303 · Cited by 380
Daisne, J.-F., Sibomana, M., Bol, A., Doumont, T., Lonneux, M., & Grégoire, V. (2003) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(03)00270-6 · Cited by 380
Lung Image Database Consortium: Developing a Resource for the Medical Imaging Research Community
Armato III, S. G., McLennan, G., McNitt-Gray, M. F., Meyer, C. R., Yankelevitz, D., Aberle, D. R., Henschke, C. I., Hoffman, E. A., Kazerooni, E. A., MacMahon, H., et al. (2004) · Radiology · doi:10.1148/radiol.2323032035 · Cited by 380
Learning Internal Representations by Error Propagation, Parallel Distributed Processing
Rumelhart, D. E. (1986) · Medical Entomology and Zoology · Cited by 374
Evaluation of primary pulmonary carcinoid tumors using FDG PET.
Erasmus, J. J., McAdams, H. P., Patz, E. F., Coleman, R. E., Ahuja, V, & Goodman, P. C. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.170.5.9574618 · Cited by 357
Pulmonary Tuberculoma Evaluated by Means of FDG PET: Findings in 10 Cases
Goo, J. M., Im, J.-G., Do, K.-H., Yeo, J. S., Seo, J. B., Kim, H. Y., & Chung, J.-K. (2000) · Radiology · doi:10.1148/radiology.216.1.r00jl19117 · Cited by 354
Nestle, U., Walter, K., Schmidt, S., Licht, N. P., Nieder, C., Motaref, B., Hellwig, D., Niewald, M., Ukena, D., Kirsch, C. M., et al. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(99)00061-9 · Cited by 353
Fluorine-18-FDG PET imaging is negative in bronchioloalveolar lung carcinoma.
Higashi, K., Ueda, Y., Seki, H., Yuasa, K., Oguchi, M., Noguchi, T., Taniguchi, M., Tonami, H., Okimura, T., & Yamamoto, I. (1998) · PubMed · Cited by 351
Artificial convolution neural network techniques and applications for lung nodule detection
Lo, S.-C. B., Lou, S.-L. A., Lin, J.-S., Freedman, M. T., Chien, M. V., & Mun, S. K. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.476112 · Cited by 348
Erdi, Y. E., Rosenzweig, K., Erdi, A. K., Macapinlac, H. A., Hu, Y.-C., Braban, L. E., Humm, J. L., Squire, O. D., Chui, C.-S., Larson, S. M., et al. (2002) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(01)00470-4 · Cited by 338
Murphy, K., van Ginneken, B., Schilham, A. M. R., de Hoop, B. J., Gietema, H. A., & Prokop, M. (2009) · Medical Image Analysis · doi:10.1016/j.media.2009.07.001 · Cited by 331
Diagnostic Efficacy of PET-FDG Imaging in Solitary Pulmonary Nodules
Dewan, N. A., Gupta, N. C., Redepenning, L. S., Phalen, J. J., & Frick, M. P. (1993) · Chest · doi:10.1378/chest.104.4.997 · Cited by 328
Artificial convolution neural network for medical image pattern recognition
Lo, S.-C. B., Chan, H.-P., Lin, J.-S., Li, H., Freedman, M. T., & Mun, S. K. (1995) · Neural Networks · doi:10.1016/0893-6080(95)00061-5 · Cited by 321
Lung Cancer Screening Using Low-Dose Spiral CT
Nawa, T., Nakagawa, T., Kusano, S., Kawasaki, Y., Sugawara, Y., & Nakata, H. (2002) · Chest · doi:10.1378/chest.122.1.15 · Cited by 315
Miss Rate of Lung Cancer on the Chest Radiograph in Clinical Practice
Quekel, L. G. B. A., Kessels, A. G. H., Goei, R., & van Engelshoven, J. M. A. (1999) · Chest · doi:10.1378/chest.115.3.720 · Cited by 311
Steenbakkers, R. J. H. M., Duppen, J. C., Fitton, I., Deurloo, K. E. I., Zijp, L. J., Comans, E. F. I., Uitterhoeve, A. L. J., Rodrigus, P. T. R., Kramer, G. W. P., Bussink, J., et al. (2006) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2005.06.034 · Cited by 309
Gurcan, M. N., Sahiner, B., Petrick, N., Chan, H., Kazerooni, E. A., Cascade, P. N., & Hadjiiski, L. (2002) · Medical Physics · doi:10.1118/1.1515762 · Cited by 309
Mah, K., Caldwell, C. B., Ung, Y. C., Danjoux, C. E., Balogh, J. M., Ganguli, S. N., Ehrlich, L. E., & Tirona, R. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(01)01824-7 · Cited by 307
Probability of malignancy in solitary pulmonary nodules using fluorine-18-FDG and PET.
Gupta, N. C., Maloof, J., & Günel, E. (1996) · PubMed · Cited by 306
Measures of Response: RECIST, WHO, and New Alternatives
Jaffe, C. C. (2006) · Journal of Clinical Oncology · doi:10.1200/jco.2006.06.5599 · Cited by 302
Shape-Based Computer-Aided Detection of Lung Nodules in Thoracic CT Images
Ye, X., Lin, X., Dehmeshki, J., Slabaugh, G., & Beddoe, G. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2017027 · Cited by 297
Lopes Pegna, A., Picozzi, G., Mascalchi, M., Maria Carozzi, F., Carrozzi, L., Comin, C., Spinelli, C., Falaschi, F., Grazzini, M., Innocenti, F., et al. (2009) · Lung Cancer · doi:10.1016/j.lungcan.2008.07.003 · Cited by 294
Godoy, M. C. B., & Naidich, D. P. (2009) · Radiology · doi:10.1148/radiol.2533090179 · Cited by 294
Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility
Wormanns, D., Kohl, G., Klotz, E., Marheine, A., Beyer, F., Heindel, W., & Diederich, S. (2004) · European Radiology · doi:10.1007/s00330-003-2132-0 · Cited by 289
Kuhnigk, J.-M., Dicken, V., Bornemann, L., Bakai, A., Wormanns, D., Krass, S., & Peitgen, H.-O. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.871547 · Cited by 288
Armato, S. G., Li, F., Giger, M. L., MacMahon, H., Sone, S., & Doi, K. (2002) · Radiology · doi:10.1148/radiol.2253011376 · Cited by 280
Segmentation of Pulmonary Nodules in Thoracic CT Scans: A Region Growing Approach
Dehmeshki, J., Amin, H., Valdivieso, M., & Ye, X. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.907555 · Cited by 277
Awai, K., Murao, K., Ozawa, A., Komi, M., Hayakawa, H., Hori, S., & Nishimura, Y. (2004) · Radiology · doi:10.1148/radiol.2302030049 · Cited by 272
Defining a radiotherapy target with positron emission tomography
Black, Q. C., Grills, I. S., Kestin, L. L., Wong, C.-Y. O., Wong, J. W., Martinez, A. A., & Yan, D. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.06.254 · Cited by 263
Suzuki, K., Armato, S. G., Li, F., Sone, S., & Doi, K. (2003) · Medical Physics · doi:10.1118/1.1580485 · Cited by 262
Self-citationBiehl, K. J., Kong, F., Dehdashti, F., Jin, J., Mutic, S., Naqa, I. E., Siegel, B. A., & Bradley, J. D. (2006) · PubMed · Cited by 260
Automated lung segmentation for thoracic CT
Armato, S. G., & Sensakovic, W. F. (2004) · Academic Radiology · doi:10.1016/j.acra.2004.06.005 · Cited by 259
Definition of gross tumor volume in lung cancer: inter-observer variability
Van de Steene, J., Linthout, N., de Mey, J., Vinh-Hung, V., Claassens, C., Noppen, M., Bel, A., & Storme, G. (2002) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(01)00453-4 · Cited by 255
Automated detection of lung nodules in CT scans: Preliminary results
Armato, S. G., Giger, M. L., & MacMahon, H. (2001) · Medical Physics · doi:10.1118/1.1387272 · Cited by 250
Paik, D. S., Beaulieu, C. F., Rubin, G. D., Acar, B., Jeffrey, R. B., Yee, J., Dey, J., & Napel, S. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.826362 · Cited by 248
Tanoue, L. T. (2011) · Yearbook of Pulmonary Disease · doi:10.1016/j.ypdi.2011.01.021 · Cited by 241
Defining a radiotherapy target with positron emission tomography
Black, Q. C., Yan, D., Kestin, L. L., Wong, C. O., Wong, J. W., & Martinez, A. A. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)03114-0 · Cited by 240
Ashamalla, H., Rafla, S., Parikh, K., Mokhtar, B., Goswami, G., Kambam, S., Abdel-Dayem, H., Guirguis, A., Ross, P., & Evola, A. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2005.04.021 · Cited by 239
Suzuki, K., Abe, H., MacMahon, H., & Doi, K. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.871549 · Cited by 237
Self-citationToward automated segmentation of the pathological lung in CT
Sluimer, I., Prokop, M., & van Ginneken, B. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.851757 · Cited by 237
Way, T. W., Hadjiiski, L. M., Sahiner, B., Chan, H., Cascade, P. N., Kazerooni, E. A., Bogot, N., & Zhou, C. (2006) · Medical Physics · doi:10.1118/1.2207129 · Cited by 224
Tan, M., Deklerck, R., Jansen, B., Bister, M., & Cornelis, J. (2011) · Medical Physics · doi:10.1118/1.3633941 · Cited by 221
Suzuki, K., Li, F., Sone, S., & Doi, K. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.852048 · Cited by 219
Self-citationKeidar, Z., Haim, N., Guralnik, L., Wollner, M., Bar‐Shalom, R., Ben‐Nun, A., & Israel, O. (2004) · PubMed · Cited by 219
McNitt-Gray, M. F., Armato, S. G., Meyer, C. R., Reeves, A. P., McLennan, G., Pais, R. C., Freymann, J., Brown, M. S., Engelmann, R. M., Bland, P. H., et al. (2007) · Academic Radiology · doi:10.1016/j.acra.2007.07.021 · Cited by 217
On measuring the change in size of pulmonary nodules
Reeves, A. P., Chan, A. B., Yankelevitz, D. F., Henschke, C. I., Kressler, B., & Kostis, W. J. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.871548 · Cited by 216
De Ruysscher, D., Wanders, S., van Haren, E., Hochstenbag, M., Geeraedts, W., Utama, I., Simons, J., Dohmen, J., Rhami, A., Buell, U., et al. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.12.019 · Cited by 214
Kostis, W. J., Yankelevitz, D. F., Reeves, A. P., Fluture, S. C., & Henschke, C. I. (2004) · Radiology · doi:10.1148/radiol.2312030553 · Cited by 206
Managing the Small Pulmonary Nodule Discovered by CT
Libby, D. M., Smith, J. P., Altorki, N. K., Pasmantier, M. W., Yankelevitz, D., & Henschke, C. I. (2004) · Chest · doi:10.1378/chest.125.4.1522 · Cited by 202
Li, F., Sone, S., Abe, H., MacMahon, H., Armato, S. G., & Doi, K. (2002) · Radiology · doi:10.1148/radiol.2253011375 · Cited by 201
Computerized Detection of Pulmonary Nodules in Computed Tomography Images
GIGER, M. L., BAE, K. T., & MacMAHON, H. (1994) · Investigative Radiology · doi:10.1097/00004424-199404000-00013 · Cited by 200
Minimal surfaces based object segmentation
Caselles, V., Kimmel, R., Sapiro, G., & Sbert, C. (1997) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.588023 · Cited by 198
Kiffer, J. D., Berlangieri, S. U., Scott, A. M., Quong, G., Feigen, M., Schumer, W., Clarke, C. P., Knight, S. R., & Daniel, F. J. (1998) · Lung Cancer · doi:10.1016/s0169-5002(97)00086-x · Cited by 187
Sun, S., Bauer, C., & Beichel, R. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2171357 · Cited by 187
McNitt‐Gray, M. F., Hart, E. M., Wyckoff, N., Sayre, J. W., Goldin, J. G., & Aberle, D. R. (1999) · Medical Physics · doi:10.1118/1.598603 · Cited by 184
Yu, H., Caldwell, C., Mah, K., & Mozeg, D. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2004425 · Cited by 184
Pulmonary Nodules: Preliminary Experience with Three-dimensional Evaluation
Revel, M., Lefort, C., Bissery, A., Bienvenu, M., Aycard, L., Châtellier, G., & Frija, G. G. (2004) · Radiology · doi:10.1148/radiol.2312030241 · Cited by 184
Hatt, M., Cheze le Rest, C., Descourt, P., Dekker, A., De Ruysscher, D., Oellers, M., Lambin, P., Pradier, O., & Visvikis, D. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.08.018 · Cited by 179
Kubota, T., Jerebko, A. K., Dewan, M., Salganicoff, M., & Krishnan, A. (2011) · Medical Image Analysis · doi:10.1016/j.media.2010.08.005 · Cited by 177
FDG-PET in radiotherapy treatment planning: Pandora's box?
Paulino, A. C., & Johnstone, P. A. S. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2003.10.045 · Cited by 176
Munley, M. T., Marks, L. B., Scarfone, C., Sibley, G. S., Patz, E. F., Turkington, T. G., Jaszczak, R. J., Gilland, D. R., Anscher, M. S., & Coleman, R. E. (1999) · Lung Cancer · doi:10.1016/s0169-5002(99)00005-7 · Cited by 171
Caldwell, C. B., Mah, K., Skinner, M., & Danjoux, C. E. (2003) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)04609-6 · Cited by 171
Patient-specific models for lung nodule detection and surveillance in CT images
Brown, M. S., McNitt-Gray, M. F., Goldin, J. G., Suh, R. D., Sayre, J. W., & Aberle, D. R. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974919 · Cited by 169
Zhang, W., Doi, K., Giger, M. L., Wu, Y., Nishikawa, R. M., & Schmidt, R. A. (1994) · Medical Physics · doi:10.1118/1.597177 · Cited by 168
van der Wel, A. M., Nijsten, S. M. J. J. G., Hochstenbag, M. M. H., Lamers, R. J. S., Boersma, L. J., Wanders, R., Lutgens, L. C. H. W., Zimny, M., Bentzen, S. M., Wouters, B. G., et al. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.06.205 · Cited by 165
de Hoop, B., Gietema, H., van Ginneken, B., Zanen, P., Groenewegen, G., & Prokop, M. (2009) · European Radiology · doi:10.1007/s00330-008-1229-x · Cited by 159
Giraud, P., Grahek, D., Montravers, F., Carette, M., Deniaud-Alexandre, É., Julia, F., Rosenwald, J., Cosset, J., Talbot, J., Housset, M., et al. (2001) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)01579-0 · Cited by 154
Herder, G., Golding, R. P., Hoekstra, O., Comans, E. F. I., Teule, G. J. J., Postmus, P. E., & Smit, E. F. (2004) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-004-1552-7 · Cited by 153
Volumetric Growth Rate of Stage I Lung Cancer prior to Treatment: Serial CT Scanning
Winer-Muram, H. T., Jennings, S. G., Tarver, R. D., Aisen, A. M., Tann, M. A., Conces, D. J., & Meyer, C. A. (2002) · Radiology · doi:10.1148/radiol.2233011026 · Cited by 153
Neural edge enhancer for supervised edge enhancement from noisy images
Suzuki, K., Horiba, I., & Sugie, N. (2003) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2003.1251151 · Cited by 152
Self-citationWay, T. W., Sahiner, B., Chan, H., Hadjiiski, L. M., Cascade, P. N., Chughtai, A. R., Bogot, N., & Kazerooni, E. A. (2009) · Medical Physics · doi:10.1118/1.3140589 · Cited by 147
Chan, H., Sahiner, B., Wagner, R. F., & Petrick, N. (1999) · Medical Physics · doi:10.1118/1.598805 · Cited by 145
Arimura, H., Katsuragawa, S., Suzuki, K., Li, F., Shiraishi, J., Sone, S., & Doi, K. (2004) · Academic Radiology · doi:10.1016/j.acra.2004.02.009 · Cited by 144
Self-citationGoodman, L. R., Gülsün, M., Washington, L., Nagy, P. G., & Piacsek, K. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.04.1821 · Cited by 144
Nakamura, K., Yoshida, H., Engelmann, R. M., MacMahon, H., Katsuragawa, S., Ishida, T., Ashizawa, K., & Doi, K. (2000) · Radiology · doi:10.1148/radiology.214.3.r00mr22823 · Cited by 144
Shi, Y., Qi, F., Xue, Z., Chen, L., Ito, K., Matsuo, H., & Shen, D. G. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.908130 · Cited by 142
Computer-Aided Detection in Screening CT for Pulmonary Nodules
Yuan, R., Vos, P. M., & Cooperberg, P. L. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.04.1969 · Cited by 139
Gietema, H. A., Schaefer‐Prokop, C. M., Mali, W. P. T. M., Groenewegen, G., & Prokop, M. (2007) · Radiology · doi:10.1148/radiol.2452061054 · Cited by 137
Hardie, R. C., Rogers, S. K., Wilson, T., & Rogers, A. (2007) · Medical Image Analysis · doi:10.1016/j.media.2007.10.004 · Cited by 135
Lee, M., Boroczky, L., Sungur-Stasik, K., Cann, A. D., Borczuk, A., Kawut, S. M., & Powell, C. A. (2010) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2010.04.011 · Cited by 131
Suzuki, K., Shiraishi, J., Abé, H., MacMahon, H., & Doi, K. (2005) · Academic Radiology · doi:10.1016/j.acra.2004.11.017 · Cited by 130
Self-citationA novel PET tumor delineation method based on adaptive region-growing and dual-front active contours
Li, H., Thorstad, W. L., Biehl, K. J., Laforest, R. A., Su, Y., Shoghi, K. I., Donnelly, E. D., Low, D. A., & Lü, W. (2008) · Medical Physics · doi:10.1118/1.2956713 · Cited by 129
3-D Segmentation Algorithm of Small Lung Nodules in Spiral CT Images
Diciotti, S., Picozzi, G., Falchini, M., Mascalchi, M., Villari, N., & Valli, G. (2008) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2007.899504 · Cited by 126
Okada, K., Comaniciu, D., & Krishnan, A. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.843172 · Cited by 124
Self-citationAutomated Segmentation Refinement of Small Lung Nodules in CT Scans by Local Shape Analysis
Diciotti, S., Lombardo, S., Falchini, M., Picozzi, G., & Mascalchi, M. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2167621 · Cited by 123
Recent progress in computer-aided diagnosis of lung nodules on thin-section CT
Li, Q. (2007) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2007.02.005 · Cited by 123
Precise Segmentation of 3-D Magnetic Resonance Angiography
El-Baz, A. S., Elnakib, A. A., Khalifa, F., El‐Ghar, M. A., McClure, P., Soliman, A., & Gimelrfarb, G. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2196434 · Cited by 122
Self-citationFeng, L., Arimura, H., Suzuki, K., Shiraishi, J., Li, Q., Abé, H., Engelmann, R. M., Sone, S., MacMahon, H., & Doi, K. (2005) · Radiology · doi:10.1148/radiol.2372041555 · Cited by 119
Self-citationMatsuki, Y., Nakamura, K., Watanabe, H., et al. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.3.1780657 · Cited by 119
Classifier performance prediction for computer‐aided diagnosis using a limited dataset
Sahiner, B., Chan, H., & Hadjiiski, L. M. (2008) · Medical Physics · doi:10.1118/1.2868757 · Cited by 116
A novel iterative method for lesion delineation and volumetric quantification with FDG PET
van Dalen, J. A., Hoffmann, A. L., Dicken, V., Vogel, W. V., Wiering, B., Ruers, T. J. M., Karssemeijer, N., & Oyen, W. J. G. (2007) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e328155d154 · Cited by 114
Woods, B., Clymer, B. D., Kurç, T., Heverhagen, J. T., Stevens, R., Orsdemir, A., Bulan, O., & Knopp, M. V. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20837 · Cited by 109
Aoyama, M., Li, Q., Katsuragawa, S., Li, F., Sone, S., & Doi, K. (2003) · Medical Physics · doi:10.1118/1.1543575 · Cited by 109
The Lung Image Database Consortium (LIDC)
Reeves, A. P., Biancardi, A., Apanasovich, T. V., Meyer, C. R., MacMahon, H., van Beek, E. J. R., Kazerooni, E. A., Yankelevitz, D. F., McNitt‐Gray, M. F., McLennan, G., et al. (2007) · Academic Radiology · doi:10.1016/j.acra.2007.09.005 · Cited by 108
A Fully Automated Method for Lung Nodule Detection From Postero-Anterior Chest Radiographs
Campadelli, P., Casiraghi, E., & Artioli, D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.884198 · Cited by 107
New Classification of Small Pulmonary Nodules by Margin Characteristics on Highresolution CT
Furuya, K., Murayama, S., Soeda, H., Murakami, J., Ichinose, Y., Yauuchi, H., Katsuda, Y., Koga, M., & Masuda, K. (1999) · Acta Radiologica · doi:10.3109/02841859909175574 · Cited by 103
Suzuki, K., Yoshida, H., Näppi, J. J., & Dachman, A. H. (2006) · Medical Physics · doi:10.1118/1.2349839 · Cited by 102
Self-citationDoubling Times and CT Screen–Detected Lung Cancers in the Pittsburgh Lung Screening Study
Wilson, D. O., Ryan, A., Fuhrman, C. R., Schuchert, M. J., Shapiro, S. D., Siegfried, J. M., & Weissfeld, J. L. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201107-1223oc · Cited by 99
Suzuki, K., Yoshida, H., Näppi, J. J., Armato, S. G., & Dachman, A. H. (2008) · Medical Physics · doi:10.1118/1.2829870 · Cited by 98
Self-citationPixel-Based Machine Learning in Medical Imaging
Suzuki, K. (2012) · International Journal of Biomedical Imaging · doi:10.1155/2012/792079 · Cited by 96
Self-citationAutomatic Segmentation of Pulmonary Segments From Volumetric Chest CT Scans
van Rikxoort, E. M., de Hoop, B., van de Vorst, S., Prokop, M., & van Ginneken, B. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2008968 · Cited by 95
Shih-Chung, B. L., Freedman, M. T., Lin, J.-S., & Mun, S. K. (1993) · Journal of Digital Imaging · doi:10.1007/bf03168418 · Cited by 94
Giger, M. L., Ahn, N., Doi, K., MacMahon, H., & Metz, C. E. (1990) · Medical Physics · doi:10.1118/1.596478 · Cited by 94
Lung nodule detection in low-dose and thin-slice computed tomography
Retico, A., Delogu, P., Fantacci, M. E., Gori, I., & Martinez, A. P. (2008) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2008.02.001 · Cited by 94
Extraction of Left Ventricular Contours From Left Ventriculograms by Means of a Neural Edge Detector
Suzuki, K., Horiba, I., Sugie, N., & Nanki, M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.824238 · Cited by 93
Self-citationTwo‐dimensional multi‐criterion segmentation of pulmonary nodules on helical CT images
Zhao, B., Yankelevitz, D. F., Reeves, A. P., & Henschke, C. I. (1999) · Medical Physics · doi:10.1118/1.598605 · Cited by 92
A multiple circular path convolution neural network system for detection of mammographic masses
Lo, S. B., Li, H., Wang, Y., Kinnard, L. M., & Freedman, M. T. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.993133 · Cited by 92
Kido, S., Kuriyama, K., Higashiyama, M., Kasugai, T., & Kuroda, C. (2002) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200207000-00017 · Cited by 90
Ge, Z., Sahiner, B., Chan, H., Hadjiiski, L. M., Cascade, P. N., Bogot, N., Kazerooni, E. A., Wei, J., & Zhou, C. (2005) · Medical Physics · doi:10.1118/1.1944667 · Cited by 87
Wang, J., Engelmann, R. M., & Li, Q. (2007) · Medical Physics · doi:10.1118/1.2799885 · Cited by 87
Distribution of Stage I Lung Cancer Growth Rates Determined with Serial Volumetric CT Measurements
Jennings, S. G., Winer-Muram, H. T., Tann, M. A., et al. (2006) · Radiology · doi:10.1148/radiol.2412051185 · Cited by 87
Quantitative surface characterization of pulmonary nodules based on thin-section CT images
Kawata, Y., Niki, N., Ohmatsu, H., Kakinuma, R., Eguchi, K., Kaneko, M., & Moriyama, N. (1998) · IEEE Transactions on Nuclear Science · doi:10.1109/23.708321 · Cited by 86
A novel multithreshold method for nodule detection in lung CT
Golosio, B., Masala, G. L., Piccioli, A., Oliva, P., Carpinelli, M., Cataldo, R., Cerello, P., Carlo, F. D., Falaschi, F., Fantacci, M. E., et al. (2009) · Medical Physics · doi:10.1118/1.3160107 · Cited by 86
Shah, S. K., McNitt‐Gray, M. F., Rogers, S. R., Goldin, J. G., Suh, R. D., Sayre, J. W., Petkovska, I., Kim, H. J., & Aberle, D. R. (2005) · Academic Radiology · doi:10.1016/j.acra.2005.06.005 · Cited by 83
Reduction of false positives in lung nodule detection using a two-level neural classification
Lin, J.-S., Lo, S.-C. B., Hasegawa, A., Freedman, M. T., & Mun, S. K. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.491422 · Cited by 80
Fuzzy hidden Markov chains segmentation for volume determination and quantitation in PET
Hatt, M., Lamare, F., Boussion, N., Turzo, A., Collet, C., Salzenstein, F., Roux, C., Jarritt, P. H., Carson, K. J., Rest, C. C. L., et al. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/12/010 · Cited by 79
Solitary pulmonary nodules: determining the likelihood of malignancy with neural network analysis.
Gurney, J. W., & Swensen, S. J. (1995) · Radiology · doi:10.1148/radiology.196.3.7644650 · Cited by 76
3D Shape Analysis for Early Diagnosis of Malignant Lung Nodules
El-Baz, A. S., Nitzken, M., Khalifa, F., Elnakib, A. A., Gimel’farb, G., Falk, R. L., & El‐Ghar, M. A. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-22092-0_63 · Cited by 74
Self-citationSegmentation of Lung Lobes in High-Resolution Isotropic CT Images
Wei, Q., Hu, Y., Gelfand, G., & MacGregor, J. H. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2014074 · Cited by 74
Pulmonary Nodules: Volume Repeatability at Multidetector CT Lung Cancer Screening
Marchianò, A. V., Calabrò, E., Civelli, E. M., Tolla, G. D., Frigerio, L. F., Morosi, C., Tafaro, F., Ferri, E., Sverzellati, N., Camerini, T., et al. (2009) · Radiology · doi:10.1148/radiol.2513081313 · Cited by 72
Medical image analysis with fuzzy models
Bezdek, J. C., Hall, L., Clark, M. C., Goldgof, D., & Clarke, L. P. (1997) · Statistical Methods in Medical Research · doi:10.1177/096228029700600302 · Cited by 71
3D Shape Analysis for Early Diagnosis of Malignant Lung Nodules
El-Baz, A. S., Nitzken, M., Elnakib, A. A., Khalifa, F., Gimel’farb, G., Falk, R. L., & El‐Ghar, M. A. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-23626-6_22 · Cited by 68
Self-citationComputer-Aided Diagnosis in Thoracic CT
Li, Q., Li, F., Suzuki, K., Shiraishi, J., Abé, H., Engelmann, R. M., Nie, Y., MacMahon, H., & Doi, K. (2005) · Seminars in Ultrasound CT and MRI · doi:10.1053/j.sult.2005.07.001 · Cited by 67
Self-citationSuzuki, K., Zhang, J., & Xu, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2053213 · Cited by 67
Self-citationRiccardi, A., Petkov, T., Ferri, G., Masotti, M., & Campanini, R. (2011) · Medical Physics · doi:10.1118/1.3560427 · Cited by 64
Suzuki, K. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/18/s03 · Cited by 63
Self-citationA New Stochastic Framework for Accurate Lung Segmentation
El-Baz, A. S., Gimel’farb, G., Falk, R. L., Holland, T., & Shaffer, T. (2008) · Lecture notes in computer science · doi:10.1007/978-3-540-85988-8_39 · Cited by 62
Self-citationEl-Baz, A. S., Farag, A. A., Falk, R. L., & Rocca, R. L. (2003) · International Congress Series · doi:10.1016/s0531-5131(03)00475-8 · Cited by 60
Self-citationMulti-stage Learning for Robust Lung Segmentation in Challenging CT Volumes
Sofka, M., Wetzl, J., Birkbeck, N., Zhang, J., Kohlberger, T., Kaftan, J. N., Declerck, J. M., & Zhou, S. K. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-23626-6_82 · Cited by 58
Suzuki, K., & Doi, K. (2005) · Academic Radiology · doi:10.1016/j.acra.2005.06.017 · Cited by 55
Self-citationAshraf, H., de Hoop, B., Shaker, S. B., et al. (2010) · European Radiology · doi:10.1007/s00330-010-1749-z · Cited by 52
Farag, A. A., El-Baz, A. S., Gimel’farb, G., Falk, R. L., & Hushek, S. G. (2004) · Lecture notes in computer science · doi:10.1007/978-3-540-30136-3_104 · Cited by 47
Self-citationA novel Gaussian Scale Space-based joint MGRF framework for precise lung segmentation
Abdollahi, B., Soliman, A., Civelek, A. C., Li, X.-F., Gimel’farb, G., & El-Baz, A. S. (2012) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2012.6467288 · Cited by 44
Self-citationPark, C. M., Goo, J. M., Lee, H. J., Kim, K. G., Kang, M., & Shin, Y. H. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.4157 · Cited by 44
Automatic segmentation of lung areas based on SNAKES and extraction of abnormal areas
Itai, Y., Kim, H., Ishikawa, S., Katsuragawa, S., Ishida, T., Nakamura, K., & Yamamoto, A. (2005) · IEEE International Conference on Tools with Artificial Intelligence (ICTAI) · doi:10.1109/ictai.2005.44 · Cited by 44
Wang, Q., Song, E., Jin, R., Han, P., Wang, X., Zhou, Y., & Zeng, J. (2009) · Academic Radiology · doi:10.1016/j.acra.2008.12.019 · Cited by 43
Farag, A. A., El-Baz, A. S., Gimel’farb, G., El‐Ghar, M. A., & El-Diasty, T. A. (2005) · Lecture notes in computer science · doi:10.1007/11566465_89 · Cited by 42
Self-citationA NOVEL FRAMEWORK FOR ACCURATE LUNG SEGMENTATION USING GRAPH CUTS
Ali, A., El-Baz, A. S., & Farag, A. A. (2007) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2007.357000 · Cited by 39
Self-citationA Novel 3D Joint MGRF Framework for Precise Lung Segmentation
Abdollahi, B., Soliman, A., Civelek, A. C., Li, X., Gimel’farb, G., & El-Baz, A. S. (2012) · Lecture notes in computer science · doi:10.1007/978-3-642-35428-1_11 · Cited by 38
Self-citationMori, K., Niki, N., Kondo, T., Kamiyama, Y., Kodama, T., Kawada, Y., & Moriyama, N. (2005) · Journal of Computer Assisted Tomography · doi:10.1097/01.rct.0000155668.28514.01 · Cited by 37
Early assessment of malignant lung nodules based on the spatial analysis of detected lung nodules
El-Baz, A. S., Soliman, A., McClure, P., et al. (2012) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2012.6235847 · Cited by 36
Self-citationKuhnigk, J., Dicken, V., Bornemann, L., Wormanns, D., Kraß, S., & Peitgen, H. (2004) · Lecture notes in computer science · doi:10.1007/978-3-540-30136-3_113 · Cited by 34
Toward Early Diagnosis of Lung Cancer
El-Baz, A. S., Gimel’farb, G., Falk, R. L., El‐Ghar, M. A., Rainey, S., Heredia, D., & Shaffer, T. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-04271-3_83 · Cited by 34
Self-citationA Framework for Unsupervised Segmentation of Lung Tissues from Low Dose Computed Tomography Images
El-Baz, A. S., Gimel’farb, G., Falk, R. L., Holland, T., & Shaffer, T. H. (2008) · British Machine Vision Conference (BMVC) · doi:10.5244/c.22.85 · Cited by 33
Self-citationFragmentary window filtering for multiscale lung nodule detection: Preliminary study
Mao, F., Qian, W., Gaviria, J., & Clarke, L. P. (1998) · Academic Radiology · doi:10.1016/s1076-6332(98)80231-6 · Cited by 31
The ${LoG}$ Characteristic Scale: A Consistent Measurement of Lung Nodule Size in CT Imaging
Diciotti, S., Lombardo, S., Coppini, G., Grassi, L., Falchini, M., & Mascalchi, M. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2032542 · Cited by 27
Scale selection for anisotropic scale-space: application to volumetric tumor characterization
Okada, K., Comaniciu, D., & Krishnan, A. (2004) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.2004.1315086 · Cited by 22
Self-citationKawata, Y., Niki, N., Ohmatsu, H., Kusumoto, M., Kakinuma, R., Mori, K., Nishiyama, H., Eguchi, K., Kaneko, M., & Moriyama, N. (2002) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2001.958637 · Cited by 22
Okada, K., Akdemir, U., & Krishnan, A. (2005) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.2005.92 · Cited by 17
Self-citationBrowder, W. A., Reeves, A. P., Apananosovich, T. V., et al. (2007) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.707775 · Cited by 17
Farag, A., El-Baz, A. S., Gimel’farb, G., & Falk, R. L. (2005) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2004.1421724 · Cited by 13
Self-citationANDS-V1 Computer Detection of Lung Nodules
Lampeter, W. A. (1985) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.949501 · Cited by 12
Computer-aided lung nodule detection in chest radiography
Carreira, M. J., Cabello, D., Penedo, M. G., & Pardo, J. M. (1995) · Lecture notes in computer science · doi:10.1007/3-540-60697-1_119 · Cited by 10
Zheng, Y., Kambhamettu, C., BAUER, T. L., & Steiner, K. V. (2009) · 2009 IEEE Computer Society Conference on Computer Vision and Pattern Recognition Workshops · doi:10.1109/cvprw.2009.5204050 · Cited by 10
Cited by
Artificial intelligence in radiology
Hosny, A., Parmar, C., Quackenbush, J., Schwartz, L. H., & Aerts, H. J. W. L. (2018) · Nature Reviews Cancer · doi:10.1038/s41568-018-0016-5 · Cited by 3,803
Results of the Two Incidence Screenings in the National Lung Screening Trial
Aberle, D. R., DeMello, S., Berg, C. D., Black, W. C., Brewer, B., Church, T. R., Clingan, K. L., Duan, F., Fagerstrom, R. M., Gareen, I. F., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1208962 · Cited by 550
Using Deep Learning for Classification of Lung Nodules on Computed Tomography Images
Song, Q., Zhao, L., Luo, X., & Dou, X. (2017) · Journal of Healthcare Engineering · doi:10.1155/2017/8314740 · Cited by 422
Shakeel, P. M., Burhanuddin, M. A., & Desa, M. I. (2019) · Measurement · doi:10.1016/j.measurement.2019.05.027 · Cited by 302
A systematic review of artificial intelligence techniques in cancer prediction and diagnosis
Kumar, Y., Gupta, S., Singla, R., & Hu, Y.-C. (2022) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-021-09648-w · Cited by 223
Metadata
- Authors
- El-Baz, A., Beache, G. M., Gimel'farb, G., Suzuki, K., Okada, K., Elnakib, A., Soliman, A., & Abdollahi, B.
- Venue
- International Journal of Biomedical Imaging
- Publisher
- Wiley
- Published
- 2013
- Volume
- 2013
- Pages
- 1-46
- ISSN
- 1687-4188 (ISSN-L)
- 1687-4196
- OpenAlex
- W2035107885
- Cited by
- 277
- References
- 200
- FWCI
- 25.77
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.