The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Initial and 6-Month Results of Biodegradable Poly- l -Lactic Acid Coronary Stents in Humans
Abstract
Background —Although metallic stents are effective in preventing acute occlusion and reducing late restenosis after coronary angioplasty, many concerns still remain. Compared with metallic stents, poly- l -lactic acid (PLLA) stents are biodegradable and can deliver drugs locally. The aim of this study was to evaluate the feasibility, safety, and efficacy of the PLLA stent. Methods and Results —Fifteen patients electively underwent PLLA Igaki-Tamai stent implantation for coronary artery stenoses. The Igaki-Tamai stent is made of a PLLA monopolymer, has a thickness of 0.17 mm, and has a zigzag helical coil pattern. A balloon-expandable covered sheath system was used, and the stent expanded by itself to its original size with an adequate temperature. A total of 25 stents were successfully implanted in 19 lesions in 15 patients, and angiographic success was achieved in all procedures. No stent thrombosis and no major cardiac event occurred within 30 days. Coronary angiography and intravascular ultrasound were serially performed 1 day, 3 months, and 6 months after the procedure. Angiographically, both the restenosis rate and target lesion revascularization rate per lesion were 10.5%; the rates per patient were 6.7% at 6 months. Intravascular ultrasound findings revealed no significant stent recoil at 1 day, and they revealed stent expansion at follow-up. No major cardiac event, except for repeat angioplasty, developed within 6 months. Conclusions —Our preliminary experience suggests that coronary PLLA biodegradable stents are feasible, safe, and effective in humans. Long-term follow-up with more patients will be required to validate the long-term efficacy of PLLA stents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Fischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
Intravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal Angioplasty
Sigwart, U., Puel, J., Mirkovitch, V., Joffre, F., & Kappenberger, L. (1987) · New England Journal of Medicine · doi:10.1056/nejm198703193161201 · Cited by 1,892
Serruys, P. W., Luijten, H. E., Beatt, K. J., Geuskens, R., de Feyter, P. J., van den Brand, M., Reiber, J. H., ten Katen, H. J., van Es, G. A., & Hugenholtz, P. G. (1988) · Circulation · doi:10.1161/01.cir.77.2.361 · Cited by 931
Arterial Remodeling After Coronary Angioplasty: A Serial Intravascular Ultrasound Study
Mintz, G. S., Popma, J. J., Pichard, A. D., Kent, K. M., Satler, L. F., Chiu Wong, S., Hong, M. K., Kovach, J. A., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.94.1.35 · Cited by 889
Nobuyoshi, M., Kimura, T., Nosaka, H., Mioka, S., Ueno, K., Yokoi, H., Hamasaki, N., Horiuchi, H., & Ohishi, H. (1988) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(88)80046-9 · Cited by 875
van der Giessen, W. J., Lincoff, A. M., Schwartz, R. S., van Beusekom, H. M. M., Serruys, P. W., Holmes, D. R., Ellis, S. G., & Topol, E. J. (1996) · Circulation · doi:10.1161/01.cir.94.7.1690 · Cited by 852
Three-Year Follow-up after Implantation of Metallic Coronary-Artery Stents
Kimura, T., Yokoi, H., Nakagawa, Y., Tamura, T., Kaburagi, S., Sawada, Y., Sato, Y., Yokoi, H., Hamasaki, N., Nosaka, H., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199602293340903 · Cited by 507
Resorbable poly(L-lactide) plates and screws for the fixation of zygomatic fractures
Bos, R. R. M., Boering, G., Rozema, F. R., & Leenslag, J. W. (1987) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/0278-2391(87)90194-7 · Cited by 324
Lincoff, A. M., Furst, J. G., Ellis, S. G., Tuch, R. J., & Topol, E. J. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00584-0 · Cited by 282
Cited by
Recent Developments in Ring Opening Polymerization of Lactones for Biomedical Applications
Albertsson, A.-C., & Varma, I. K. (2003) · Biomacromolecules · doi:10.1021/bm034247a · Cited by 1,582
Biodegradable synthetic polymers: Preparation, functionalization and biomedical application
Tian, H., Tang, Z., Zhuang, X., Chen, X., & Jing, X. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.06.004 · Cited by 1,293
Recent advances in shape memory polymers and composites: a review
Ratna, D., & Karger-Kocsis, J. (2008) · Journal of Materials Science · doi:10.1007/s10853-007-2176-7 · Cited by 942
Erbel, R., Di Mario, C., Bartunek, J., Bonnier, J., de Bruyne, B., Eberli, F. R., Erne, P., Haude, M., Heublein, B., Horrigan, M., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60853-8 · Cited by 907
Coronary stents: A materials perspective
Mani, G., Feldman, M. D., Patel, D., & Agrawal, C. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.042 · Cited by 866
Serruys, P. W., Ormiston, J. A., Onuma, Y., Regar, E., Gonzalo, N., Garcia-Garcia, H. M., Nieman, K., Bruining, N., Dorange, C., Miquel-Hébert, K., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60325-1 · Cited by 820
Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
Heublein, B., Rohde, R., Kaese, V, Niemeyer, M., Hartung, W., & Haverich, A. (2003) · Heart · doi:10.1136/heart.89.6.651 · Cited by 806
Serruys, P. W., Kutryk, M. J. B., & Ong, A. T. L. (2006) · New England Journal of Medicine · doi:10.1056/nejmra051091 · Cited by 762
Ormiston, J. A., Serruys, P. W., Regar, E., Dudek, D., Thuesen, L., Webster, M. W., Onuma, Y., Garcia-Garcia, H. M., McGreevy, R., & Veldhof, S. (2008) · The Lancet · doi:10.1016/s0140-6736(08)60415-8 · Cited by 712
Sankara Narayanan, T. S. N., Park, I. S., & Lee, M. H. (2014) · Progress in Materials Science · doi:10.1016/j.pmatsci.2013.08.002 · Cited by 639
Piezoelectric materials for tissue regeneration: A review
Rajabi, A. H., Jaffe, M., & Arinzeh, T. L. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.07.010 · Cited by 635
Yakacki, C. M., Shandas, R., Lanning, C., Rech, B., Eckstein, A., & Gall, K. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.01.030 · Cited by 618
Developments in metallic biodegradable stents☆
Hermawan, H., Dubé, D., & Mantovani, D. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.10.006 · Cited by 604
Peuster, M., Wohlsein, P., Brügmann, M., Ehlerding, M., Seidler, K., Fink, C., Brauer, H., Fischer, A., & Hausdorf, G. (2001) · Heart · doi:10.1136/heart.86.5.563 · Cited by 569
Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta
Peuster, M., Hesse, C., Schloo, T., Fink, C., Beerbaum, P., & von Schnakenburg, C. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.05.029 · Cited by 558
Biodegradable Metals for Cardiovascular Stents: from Clinical Concerns to Recent Zn‐Alloys
Bowen, P. K., Shearier, E. R., Zhao, S., Guillory, R. J., Zhao, F., Goldman, J., & Drelich, J. W. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201501019 · Cited by 544
Serruys, P. W., Onuma, Y., Dudek, D., Smits, P. C., Koolen, J., Chevalier, B., de Bruyne, B., Thuesen, L., McClean, D., van Geuns, R.-J., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.05.050 · Cited by 525
Molecular Basis of Restenosis and Drug-Eluting Stents
Costa, M. A., & Simon, D. I. (2005) · Circulation · doi:10.1161/01.cir.0000163587.36485.a7 · Cited by 510
A review of drug delivery systems based on nanotechnology and green chemistry: green nanomedicine
Jahangirian, H., Ghasemian lemraski, E., Webster, T. J., Rafiee-Moghaddam, R., & Abdollahi, Y. (2017) · International Journal of Nanomedicine · doi:10.2147/ijn.s127683 · Cited by 496
A Possible Biodegradable Magnesium Implant Material
Song, G., & Song, S. (2007) · Advanced Engineering Materials · doi:10.1002/adem.200600252 · Cited by 487
Onuma, Y., & Serruys, P. W. (2011) · Circulation · doi:10.1161/circulationaha.110.971606 · Cited by 434
Drug‐Eluting Bioabsorbable Magnesium Stent
DI MARIO, C., GRIFFITHS, H., GOKTEKIN, O., PEETERS, N., VERBIST, J., BOSIERS, M., DELOOSE, K., HEUBLEIN, B., ROHDE, R., KASESE, V., et al. (2004) · Journal of Interventional Cardiology · doi:10.1111/j.1540-8183.2004.04081.x · Cited by 428
Organic Thin‐Film Transistors Fabricated on Resorbable Biomaterial Substrates
Bettinger, C. J., & Bao, Z. (2010) · Advanced Materials · doi:10.1002/adma.200902322 · Cited by 423
Haude, M., Erbel, R., Erne, P., Verheye, S., Degen, H., Böse, D., Vermeersch, P., Wijnbergen, I., Weissman, N., Prati, F., et al. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61765-6 · Cited by 423
Shape‐Memory Polymers for Biomedical Applications
Delaey, J., Dubruel, P., & Van Vlierberghe, S. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201909047 · Cited by 407
Fe–Mn alloys for metallic biodegradable stents: Degradation and cell viability studies☆
Hermawan, H., Purnama, A., Dube, D., Couet, J., & Mantovani, D. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.11.025 · Cited by 372
Electrical stimulation and piezoelectric biomaterials for bone tissue engineering applications.
Khare, D., Basu, B., & Dubey, A. K. (2020) · PubMed · doi:10.1016/j.biomaterials.2020.120280 · Cited by 354
The heart failure epidemic: exactly how big is it?
Cleland, J. (2001) · European Heart Journal · doi:10.1053/euhj.2000.2493 · Cited by 330
Safety and efficacy of bioabsorbable magnesium alloy stents in porcine coronary arteries
Waksman, R., Pakala, R., Kuchulakanti, P. K., Baffour, R., Hellinga, D., Seabron, R., Tio, F. O., Wittchow, E., Hartwig, S., Harder, C., et al. (2006) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20727 · Cited by 330
Garg, S., & Serruys, P. W. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.008 · Cited by 306
Ormiston, J. A., & Serruys, P. W. S. (2009) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.109.859173 · Cited by 305
Serruys, P. W., Garcia-Garcia, H. M., & Onuma, Y. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr384 · Cited by 303
Zhao, W., Zhang, F., Leng, J., & Liu, Y. (2019) · Composites Science and Technology · doi:10.1016/j.compscitech.2019.107866 · Cited by 279
Peeters, P., Bosiers, M., Verbist, J., Deloose, K., & Heublein, B. (2005) · Journal of Endovascular Therapy · doi:10.1583/04-1349r.1 · Cited by 275
Bioresorbable scaffolds: rationale, current status, challenges, and future
Iqbal, J., Onuma, Y., Ormiston, J., Abizaid, A., Waksman, R., & Serruys, P. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht542 · Cited by 269
Bergström, J. S., & Hayman, D. (2016) · Annals of Biomedical Engineering · doi:10.1007/s10439-015-1455-8 · Cited by 266
Jamesh, M., Kumar, S., & Sankara Narayanan, T. S. N. (2011) · Corrosion Science · doi:10.1016/j.corsci.2010.10.011 · Cited by 262
Metallic zinc exhibits optimal biocompatibility for bioabsorbable endovascular stents
Bowen, P. K., Guillory, R. J., Shearier, E. R., Seitz, J.-M., Drelich, J., Bocks, M., Zhao, F., & Goldman, J. (2015) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.07.022 · Cited by 261
Biopolymers in Medical Implants: A Brief Review
Rebelo, R., Fernandes, M., & Fangueiro, R. (2017) · Procedia Engineering · doi:10.1016/j.proeng.2017.07.034 · Cited by 259
Current Status of Bioresorbable Scaffolds in the Treatment of Coronary Artery Disease
Wiebe, J., Nef, H. M., & Hamm, C. W. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.09.041 · Cited by 255
The Road to Bioabsorbable Stents: Reaching Clinical Reality?
Erne, P., Schier, M., & Resink, T. J. (2006) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-004-0341-9 · Cited by 249
Bio-resorbable polymer stents: a review of material progress and prospects
McMahon, S., Bertollo, N., Cearbhaill, E. D. O., Salber, J., Pierucci, L., Duffy, P., Dürig, T., Bi, V., & Wang, W. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.05.002 · Cited by 194
Long-term surveillance of zinc implant in murine artery: Surprisingly steady biocorrosion rate
Drelich, A. J., Zhao, S., Guillory, R. J., Drelich, J. W., & Goldman, J. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.05.045 · Cited by 188
Research Progress of Shape Memory Polymer and 4D Printing in Biomedical Application
Zhao, W., Yue, C., Liu, L., Liu, Y., & Leng, J. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202201975 · Cited by 183
Rapidly Self-Expandable Polymeric Stents with a Shape-Memory Property
Chen, M.-C., Tsai, H.-W., Chang, Y., Lai, W.-Y., Mi, F.-L., Liu, C.-T., Wong, H.-S., & Sung, H.-W. (2007) · Biomacromolecules · doi:10.1021/bm7004615 · Cited by 160
Effect of the molecular weight on the crystallinity of PCL-b-PLLA di-block copolymers
Peponi, L., Navarro-Baena, I., Báez, J. E., Kenny, J. M., & Marcos-Fernández, A. (2012) · Polymer · doi:10.1016/j.polymer.2012.07.066 · Cited by 109
Constitutive Framework for Biodegradable Polymers with Applications to Biodegradable Stents
Soares, J. S., Moore, J. E., & Rajagopal, K. R. (2008) · ASAIO Journal · doi:10.1097/mat.0b013e31816ba55a · Cited by 106
Baer, G. M., Wilson, T. S., Small, W., Hartman, J., Benett, W. J., Matthews, D. L., & Maitland, D. J. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31301 · Cited by 67
Functional fatigue of shape memory polymers
Schmidt, C., Neuking, K., & Eggeler, G. (2008) · Advanced Engineering Materials · doi:10.1002/adem.200800213 · Cited by 55
The Effect of Static and Dynamic Loading on Degradation of PLLA Stent Fibers
Hayman, D., Bergerson, C., Miller, S., Moreno, M., & Moore, J. E. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4027614 · Cited by 48
3D printing of implantable elastic PLCL copolymer scaffolds
Liu, W., Feng, Z., Ou-Yang, W., Pan, X., Wang, X., Huang, P., Zhang, C., Kong, D., & Wang, W. (2020) · Soft Matter · doi:10.1039/c9sm02396h · Cited by 43
Chausse, V., Iglesias, C., Bou-Petit, E., Ginebra, M.-P., & Pegueroles, M. (2023) · Polymer Testing · doi:10.1016/j.polymertesting.2022.107817 · Cited by 39
Shape memory polymers: properties, synthesis and applications
Peponi, L., Navarro-Baena, I., & Kenny, J. M. (2014) · Smart Polymers and their Applications · doi:10.1533/9780857097026.1.204 · Cited by 38
Dong, J., Liao, L., Ma, Y., Shi, L., Wang, G., Fan, Z., Li, S., & Lu, Z. (2014) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2014.03.004 · Cited by 35
Bioresorbable Stents: Is This Where We Are Headed?
Wayangankar, S. A., & Ellis, S. G. (2015) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2015.08.011 · Cited by 18
Du, Y., Xing, L., Hou, P., Qi, J., Liu, X., Zhang, Y., Chen, D., Li, Q., Xiong, C., Huang, T., et al. (2022) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2022.129244 · Cited by 14
Metadata
- Authors
- Tamai, H., Igaki, K., Kyo, E., Kosuga, K., Kawashima, A., Matsui, S., Komori, H., Tsuji, T., Motohara, S., & Uehata, H.
- Venue
- Circulation
- Published
- 2000-07-25
- Volume
- 102
- Issue
- 4
- Pages
- 399-404
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2166932054
- Cited by
- 806
- References
- 18
- FWCI
- 18.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.