The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Remote plethysmographic imaging using ambient light
Open accessAbstract
Plethysmographic signals were measured remotely (> 1m) using ambient light and a simple consumer level digital camera in movie mode. Heart and respiration rates could be quantified up to several harmonics. Although the green channel featuring the strongest plethysmographic signal, corresponding to an absorption peak by (oxy-) hemoglobin, the red and blue channels also contained plethysmographic information. The results show that ambient light photo-plethysmography may be useful for medical purposes such as characterization of vascular skin lesions (e.g., port wine stains) and remote sensing of vital signs (e.g., heart and respiration rates) for triage or sports purposes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Determination of Hemoglobin and Its Derivatives
(1966) · Advances in Clinical Chemistry · doi:10.1016/s0065-2423(08)60414-x · Cited by 349
Wieringa, F. P., Mastik, F., & Steen, A. F. W. V. D. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-5763-2 · Cited by 284
Tissue parameters determining the visual appearance of normal skin and port-wine stains
Svaasand, L. O., Norvang, L. T., Fiskerstrand, E. J., Stopps, E. K. S., Berns, M. W., & Nelson, J. S. (1995) · Lasers in Medical Science · doi:10.1007/bf02133165 · Cited by 157
Self-citationEffects of motion, ambient light, and hypoperfusion on pulse oximeter function
Trivedi, N. S., Ghouri, A. F., Shah, N. K., Lai, E., & Barker, S. J. (1997) · Journal of Clinical Anesthesia · doi:10.1016/s0952-8180(97)00039-1 · Cited by 140
Forrester, K., Stewart, C. J., TULIP, J., Leonard, C. A., & Bray, R. C. (2002) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345307 · Cited by 128
Photoplethysmography: Part 2 Influence of light source wavelength
Lindberg, L., & Öberg, P. Å. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446295 · Cited by 118
Verkruysse, W., Lucassen, G. W., de Boer, J. F., Smithies, D. J., Nelson, J. S., & van Gemert, M. J. C. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/1/003 · Cited by 112
Self-citationPulsatile blood flow in the entire coronary arterial tree: theory and experiment
Huo, Y., & Kassab, G. S. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00200.2006 · Cited by 98
Feasibility of Imaging Photoplethysmography
Zheng, J., Hu, S., Chouliaras, V. A., & Summers, R. (2008) · International Conference on Biomedical Engineering and Informatics (BMEI) · doi:10.1109/bmei.2008.365 · Cited by 84
Cited by
Non-contact, automated cardiac pulse measurements using video imaging and blind source separation
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2010) · Optics Express · doi:10.1364/oe.18.010762 · Cited by 1,643
Advancements in Noncontact, Multiparameter Physiological Measurements Using a Webcam
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2086456 · Cited by 1,486
Robust pulse rate from chrominance-based rPPG
de Haan, G., & Jeanne, V. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2266196 · Cited by 1,378
“Publications have even shown successful rPPG using a regular color video camera in the ambient light conditions [4]–[7].”
BackgroundMethodEulerian video magnification for revealing subtle changes in the world
Wu, H.-Y., Rubinstein, M., Shih, E., Guttag, J., Durand, F., & Freeman, W. (2012) · ACM Transactions on Graphics · doi:10.1145/2185520.2185561 · Cited by 1,357
Algorithmic principles of remote PPG
Wang, W., den Brinker, A. C., Stuijk, S., & de Haan, G. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2609282 · Cited by 1,234
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
“The green signal was found to provide the strongest plethysmographic signal among camera RGB signals [11,12].”
BackgroundDeepPhys: Video-Based Physiological Measurement Using Convolutional Attention Networks
Chen, W., & McDuff, D. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-01216-8_22 · Cited by 716
Unsupervised skin tissue segmentation for remote photoplethysmography
Bobbia, S., Macwan, R., Benezeth, Y., Mansouri, A., & Dubois, J. (2019) · Pattern Recognition Letters · doi:10.1016/j.patrec.2017.10.017 · Cited by 615
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 556
Detecting Pulse from Head Motions in Video
Balakrishnan, G., Durand, F., & Guttag, J. (2013) · 2013 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2013.440 · Cited by 553
Remote Heart Rate Measurement from Face Videos under Realistic Situations
Li, X., Chen, J., Zhao, G., & Pietikainen, M. (2014) · 2014 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2014.543 · Cited by 550
Improved motion robustness of remote-PPG by using the blood volume pulse signature
de Haan, G., & van Leest, A. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/9/1913 · Cited by 491
Non-contact video-based pulse rate measurement on a mobile service robot
Stricker, R., Muller, S., & Gross, H.-M. (2014) · The 23rd IEEE International Symposium on Robot and Human Interactive Communication · doi:10.1109/roman.2014.6926392 · Cited by 456
Physiological parameter monitoring from optical recordings with a mobile phone
Scully, C. G., Lee, J., Meyer, J., Gorbach, A. M., Granquist-Fraser, D., Mendelson, Y., & Chon, K. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2163157 · Cited by 452
Smartphone Sensors for Health Monitoring and Diagnosis
Majumder, S., & Deen, M. J. (2019) · Sensors · doi:10.3390/s19092164 · Cited by 435
Non-contact video-based vital sign monitoring using ambient light and auto-regressive models
Tarassenko, L., Villarroel, M., Guazzi, A., Jorge, J., Clifton, D. A., & Pugh, C. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/5/807 · Cited by 423
DistancePPG: Robust non-contact vital signs monitoring using a camera
Kumar, M., Veeraraghavan, A., & Sabharwal, A. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.001565 · Cited by 417
RhythmNet: End-to-End Heart Rate Estimation From Face via Spatial-Temporal Representation
Niu, X., Shan, S., Han, H., & Chen, X. (2020) · IEEE Transactions on Image Processing · doi:10.1109/tip.2019.2947204 · Cited by 420
Toward a Robust Estimation of Respiratory Rate From Pulse Oximeters
Pimentel, M. A. F., Johnson, A. E. W., Charlton, P. H., Birrenkott, D., Watkinson, P. J., Tarassenko, L., & Clifton, D. A. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2613124 · Cited by 387
A Novel Algorithm for Remote Photoplethysmography: Spatial Subspace Rotation
Wang, W., Stuijk, S., & de Haan, G. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2508602 · Cited by 370
Tulyakov, S., Alameda-Pineda, X., Ricci, E., Yin, L., Cohn, J. F., & Sebe, N. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.263 · Cited by 340
Yu, Z., Peng, W., Li, X., Hong, X., & Zhao, G. (2019) · 2019 IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2019.00024 · Cited by 340
Automated Detection of Engagement Using Video-Based Estimation of Facial Expressions and Heart Rate
Monkaresi, H., Bosch, N., Calvo, R. A., & D'Mello, S. K. (2017) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2016.2515084 · Cited by 329
Non-contact heart rate and heart rate variability measurements: A review
Kranjec, J., Beguš, S., Geršak, G., & Drnovšek, J. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2014.03.004 · Cited by 318
Remote measurement of cognitive stress via heart rate variability
McDuff, D., Gontarek, S., & Picard, R. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6944243 · Cited by 308
PhysFormer: Facial Video-based Physiological Measurement with Temporal Difference Transformer
Yu, Z., Shen, Y., Shi, J., Zhao, H., Torr, P., & Zhao, G. (2022) · 2022 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr52688.2022.00415 · Cited by 300
Improvements in Remote Cardiopulmonary Measurement Using a Five Band Digital Camera
McDuff, D., Gontarek, S., & Picard, R. W. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2323695 · Cited by 287
Exploiting Spatial Redundancy of Image Sensor for Motion Robust rPPG
Wang, W., Stuijk, S., & de Haan, G. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2356291 · Cited by 284
Cuffless Blood Pressure Measurement
Mukkamala, R., Stergiou, G. S., & Avolio, A. P. (2022) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110220-014644 · Cited by 180
Algorithms for Monitoring Heart Rate and Respiratory Rate From the Video of a User’s Face
Sanyal, S., & Nundy, K. K. (2018) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2018.2818687 · Cited by 125
Remote PPG based vital sign measurement using adaptive facial regions
Tasli, H. E., Gudi, A., & den Uyl, M. (2014) · 2014 IEEE International Conference on Image Processing (ICIP) · doi:10.1109/icip.2014.7025282 · Cited by 99
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbuchel, H., Hu, Y.-F., Chen, L. Y., Couderc, J.-P., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.120.009204 · Cited by 74
Simultaneous monitoring of ballistocardiogram and photoplethysmogram using a camera
Shao, D., Tsow, F., Liu, C., Yang, Y., & Tao, N. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2585109 · Cited by 69
Nowara, E. M., McDuff, D., & Veeraraghavan, A. (2020) · 2020 IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw50498.2020.00150 · Cited by 66
Moço, A., & Verkruysse, W. (2021) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-019-00449-y · Cited by 55
Imaging Photoplethysmography: What are the Best Locations on the Face to Estimate Heart Rate?
Fallet, S., Moser, V., Braun, F., & Vesin, J.-M. (2016) · 2016 Computing in Cardiology Conference (CinC) · doi:10.22489/cinc.2016.098-236 · Cited by 28
“This study aimed at investigating the spatial distribution of the HR-related information on the subject face, based on a partition into 260 small ROIs.”
Allado, E., Poussel, M., Moussu, A., Saunier, V., Bernard, Y., Albuisson, E., & Chenuel, B. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-047896 · Cited by 22
PhysFlow: Skin tone transfer for remote heart rate estimation through conditional normalizing flows
Comas, J., Alomar, A., Ruiz, A., & Sukno, F. (2024) · arXiv · doi:10.48550/arxiv.2407.21519 · Cited by 4
“Since Takano et al. [51] and Verkruysse et al. [56] demonstrated remote HR measurement feasibility from facial videos, diverse methods for physiological data recovery have emerged.”
Method
Metadata
- Authors
- Verkruysse, W., Svaasand, L. O., & Nelson, J. S.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2008-12-12
- Volume
- 16
- Issue
- 26
- Pages
- 21434
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2003922338
- Cited by
- 1,719
- References
- 16
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.