Application of Chronic Intravascular Blood Glucose Sensor in Dogs
The DOI matches its Crossref record.
Abstract
An intravenous glucose sensor was implanted in six dogs for 1–15 wk. The glucose sensor is a flexible cylinder, ∼0.2 cm diam and 30 cm long, with a tip containing immobilized glucose oxidase and catalase coupled to a potentiostatic O2 sensor. The sensor and a similar O2 reference sensor were implanted in the superior vena cava near the entrance of the right atrium. The sensor response was conveyed externally either by a telemetry system implanted nearby, surgically accessed leads, or chronically maintained percutaneous leads. Summing over the six implants, there was a total implantation period of 333 days during which glucose sensors were functional on demand. The sensor response showed agreement with conventionally assayed blood samples after accounting for a response lag. Sensor response to glucose showed little change over the implant period. Biocompatibility, enzyme lifetime, O2 availability, O2 sensor stability, and biochemical interference were not limitations. Results demonstrated that this sensor can function effectively as an implant in dogs for a period of months and has the potential for long-term operation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Electrochemical Non-enzymatic Glucose Sensors: A Perspective and an Evaluation
Toghill, K. E., & Compton, R. G. (2010) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15359-4 · Cited by 926
Recent advances in electrochemical glucose biosensors: a review
Chen, C., Xie, Q., Yang, D., Xiao, H., Fu, Y., Tan, Y., & Yao, S. (2013) · RSC Advances · doi:10.1039/c2ra22351a · Cited by 807
Hydrogels in sensing applications
Buenger, D., Topuz, F., & Groll, J. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.09.001 · Cited by 762
Glucose Biosensors: 40 Years of Advances and Challenges
Wang, J. (2001) · Electroanalysis · doi:10.1002/1521-4109(200108)13:12<983::aid-elan983>3.0.co;2-# · Cited by 752
A Critical Review of Glucose Biosensors Based on Carbon Nanomaterials: Carbon Nanotubes and Graphene
Zhu, Z., Garcia-Gancedo, L., Flewitt, A. J., Xie, H., Moussy, F., & Milne, W. I. (2012) · Sensors · doi:10.3390/s120505996 · Cited by 549
Methods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543
Enzyme-Based Biosensors for in Vivo Measurements
Wilson, G. S., & Hu, Y. (2000) · Chemical Reviews · doi:10.1021/cr990003y · Cited by 434
Emerging synergy between nanotechnology and implantable biosensors: A review
Vaddiraju, S., Tomazos, I., Burgess, D. J., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.001 · Cited by 368
Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring
Bindra, D. S., Zhang, Y., Wilson, G. S., Sternberg, R., Thevenot, D. R., Moatti, D., & Reach, G. (1991) · Analytical Chemistry · doi:10.1021/ac00017a008 · Cited by 309
Lee, I., Probst, D., Klonoff, D., & Sode, K. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113054 · Cited by 288
Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, S., Burgess, D. J., Tomazos, I., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400632 · Cited by 285
Implanted Electrochemical Glucose Sensors for the Management of Diabetes
Heller, A. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.153 · Cited by 215
In vivo glucose monitoring: the clinical reality and the promise
Pickup, J. C., Hussain, F., Evans, N. D., & Sachedina, N. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.08.016 · Cited by 203
Koschwanez, H. E., & Reichert, W. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.034 · Cited by 181
Emerging biomedical sensing technologies and their applications
Cote, G. L., Lec, R. M., & Pishko, M. V. (2003) · IEEE Sensors Journal · doi:10.1109/jsen.2003.814656 · Cited by 180
“developed a glucose sensor for long-term implantation within the blood stream [8].”
BackgroundGlucose monitoring: state of the art and future possibilities
Wilkins, E., & Atanasov, P. (1996) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)00046-1 · Cited by 180
Function of an Implanted Tissue Glucose Sensor for More than 1 Year in Animals
Gough, D. A., Kumosa, L. S., Routh, T. L., Lin, J. T., & Lucisano, J. Y. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3001148 · Cited by 179
Self-citationIn-Vivo Electrochemistry: What Can We Learn about Living Systems?
Wilson, G. S., & Johnson, M. A. (2008) · Chemical Reviews · doi:10.1021/cr068082i · Cited by 178
Quinn, C. P., Pathak, C. P., Heller, A., & Hubbell, J. A. (1995) · Biomaterials · doi:10.1016/0142-9612(95)98856-9 · Cited by 172
Biocompatible, glucose-permeable hydrogel for in situ coating of implantable biosensors
Quinn, C. A. P., Connor, R. E., & Heller, A. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00125-7 · Cited by 126
Calibration of a subcutaneous amperometric glucose sensor implanted for 7 days in diabetic patients
Choleau, C., Klein, J. C., Reach, G., Aussedat, B., Demaria-Pesce, V., Wilson, G. S., Gifford, R., & Ward, W. K. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00304-9 · Cited by 76
“In a first configuration, the glucose sensor is indwelled in the vascular bed (direct blood glucose monitoring); even though such systems have been successfully evaluated in a limited number of dogs for several months (Armour et al., 1990), such an approach requires the invasive access to a major blood vessel, and the…”
BackgroundIn vivo glucose sensing for diabetes management: progress towards non-invasive monitoring
Pickup, J., McCartney, L., Rolinski, O., & Birch, D. (1999) · BMJ · doi:10.1136/bmj.319.7220.1289 · Cited by 66
Novak, M. T., Yuan, F., & Reichert, W. M. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4097-6 · Cited by 55
Ertefai, S., & Gough, D. A. (1989) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(89)90097-6 · Cited by 52
Self-citationJu, Y. M., Yu, B., West, L., Moussy, Y., & Moussy, F. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32400 · Cited by 52
“Armour et al.(14) implanted 6 sensors intravascularly in dogs for up to 108 days.”
Simulations of the Frequency Response of Implantable Glucose Sensors
Jablecki, M., & Gough, D. A. (2000) · Analytical Chemistry · doi:10.1021/ac991018z · Cited by 24
Self-citationVariants of the tissue-sensor array window chamber
Makale, M. T., Chen, P. C., & Gough, D. A. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01001.2004 · Cited by 16
Self-citation
Metadata
- Authors
- Armour, J. C., Lucisano, J. Y., McKean, B. D., & Gough, D. A.
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 1990-12-01
- Volume
- 39
- Issue
- 12
- Pages
- 1519-1526
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- OpenAlex
- W2023313136
- Cited by
- 175
- References
- 0
- FWCI
- 9.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.