The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Intra-Osseous Anchorage of Dental Prostheses:I. Experimental Studies
Abstract
An investigation of factors controlling healing and long term stability of intra-osseous titanium implants to restore masticatory function in dogs revealed that an integrity of the good anchorage of the implant requires: (1) Non-traumatic surgical preparation of soft and hard tissues and a mechanically and chemically clean implant. (2) Primary closure of the mucoperiosteal flap, to isolate the implant site from the oral cavity until a biological barrier has been reestablished. (3) Oral hygiene to prevent gingival inflammation. Provided these precautions are taken, it is possible to subject dental prostheses, connected to the implants, to unlimited masticatory load. With these precautions such implants were found to tolerate ordinary use in dogs for periods of more than 5 years without signs of tissue injury or other indications of rejection phenomena.Macroscopic clinical investigation, stereomicroscopy, roentgenography and light microscopy of the implant site in situ and after removal from the body showed that the soft and hard tissues had accepted the implant and incorporated it without producing signs of tissue injury. In fact the bone appeared to grow into all the minute pits and impressions in the surface of the titanium implant, without any shielding layer of buffer tissue at all.These findings indicate that dental prostheses can be successfully anchored intra-osseously in the dog suggesting that its possible clinical use in oral rehabilitation should be given unprejudiced consideration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Progress in implant dentistry—An evaluation
Lew, I. (1959) · The Journal of the American Dental Association · doi:10.14219/jada.archive.1959.0200 · Cited by 13
Cited by
A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
Adell, R., Lekholm, U., Rockler, B., & Brånemark, P.-I. (1981) · International Journal of Oral Surgery · doi:10.1016/s0300-9785(81)80077-4 · Cited by 4,816
Self-citationAlbrektsson, T., Brånemark, P.-I., Hansson, H.-A., & Lindström, J. (1981) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678108991776 · Cited by 2,690
Self-citationBuser, D., Schenk, R. K., Steinemann, S., Fiorellini, J. P., Fox, C. H., & Stich, H. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250708 · Cited by 1,719
Advancing dental implant surface technology – From micron- to nanotopography
Mendonça, G., Mendonça, D. B. S., Aragão, F. J. L., & Cooper, L. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.05.012 · Cited by 990
Szmukler-Moncler, S., Salama, H., Reingewirtz, Y., & Dubruille, J. H. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199822)43:2<192::aid-jbm14>3.0.co;2-k · Cited by 794
Buser, D., Sennerby, L., & De Bruyn, H. (2017) · Periodontology 2000 · doi:10.1111/prd.12185 · Cited by 792
Moraschini, V., Poubel, L. A. D. C., Ferreira, V. F., & Barboza, E. D. S. P. (2015) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2014.10.023 · Cited by 729
Significance of calcium phosphate coatings for the enhancement of new bone osteogenesis – A review
Surmenev, R. A., Surmeneva, M. A., & Ivanova, A. A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.10.036 · Cited by 712
Impact of Dental Implant Surface Modifications on Osseointegration
Smeets, R., Stadlinger, B., Schwarz, F., Beck-Broichsitter, B., Jung, O., Precht, C., Kloss, F., Gröbe, A., Heiland, M., & Ebker, T. (2016) · BioMed Research International · doi:10.1155/2016/6285620 · Cited by 701
Cochran, D. L., Schenk, R. K., Lussi, A., Higginbottom, F. L., & Buser, D. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199804)40:1<1::aid-jbm1>3.0.co;2-q · Cited by 690
De novo alveolar bone formation adjacent to endosseous implants: A model study in the dog
Berglundh, T., Abrahamsson, I., Lang, N. P., & Lindhe, J. (2003) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2003.00972.x · Cited by 689
Hermann, J. S., Cochran, D. L., Nummikoski, P. V., & Buser, D. (1997) · Journal of Periodontology · doi:10.1902/jop.1997.68.11.1117 · Cited by 678
Buser, D., Janner, S. F. M., Wittneben, J., Brägger, U., Ramseier, C. A., & Salvi, G. E. (2012) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2012.00456.x · Cited by 642
Surface characteristics of dental implants: A review
Rupp, F., Liang, L., Geis-Gerstorfer, J., Scheideler, L., & Hüttig, F. (2018) · Dental Materials · doi:10.1016/j.dental.2017.09.007 · Cited by 585
Bosshardt, D. D., Chappuis, V., & Buser, D. (2017) · Periodontology 2000 · doi:10.1111/prd.12179 · Cited by 574
The Causes of Early Implant Bone Loss: Myth or Science?
Oh, T., Yoon, J., Misch, C. E., & Wang, H. (2002) · Journal of Periodontology · doi:10.1902/jop.2002.73.3.322 · Cited by 572
Cochran, D. L., Buser, D., Ten Bruggenkate, C. M., Weingart, D., Taylor, T. M., Bernard, J., Peters, F., & Simpson, J. P. (2002) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2002.130204.x · Cited by 568
Nano-scale modification of titanium implant surfaces to enhance osseointegration
Souza, J. C. M., Sordi, M. B., Kanazawa, M., Ravindran, S., Henriques, B., Silva, F. S., Aparicio, C., & Cooper, L. F. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.05.045 · Cited by 544
Effects of implant surface coatings and composition on bone integration: a systematic review
Junker, R., Dimakis, A., Thoneick, M., & Jansen, J. A. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01777.x · Cited by 535
Fernandez-Yague, M. A., Abbah, S. A., McNamara, L., Zeugolis, D. I., Pandit, A., & Biggs, M. J. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.09.005 · Cited by 523
A review on the wettability of dental implant surfaces I: Theoretical and experimental aspects
Rupp, F., Gittens, R. A., Scheideler, L., Marmur, A., Boyan, B. D., Schwartz, Z., & Geis-Gerstorfer, J. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.02.040 · Cited by 507
Eriksson, R. A., & Albrektsson, T. (1984) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/0278-2391(84)90417-8 · Cited by 506
Cochran, D. L., Hermann, J. S., Schenk, R. K., Higginbottom, F. L., & Buser, D. (1997) · Journal of Periodontology · doi:10.1902/jop.1997.68.2.186 · Cited by 504
A review of dental implants and infection
Pye, A. D., Lockhart, D. E. A., Dawson, M. P., Murray, C. A., & Smith, A. J. (2009) · Journal of Hospital Infection · doi:10.1016/j.jhin.2009.02.010 · Cited by 487
Peri-implant Inflammation Defined by the Implant-Abutment Interface
Broggini, N., McManus, L. M., Hermann, J. S., Medina, R., Schenk, R. K., Buser, D., & Cochran, D. L. (2006) · Journal of Dental Research · doi:10.1177/154405910608500515 · Cited by 480
Buser, D., Chappuis, V., Belser, U. C., & Chen, S. (2017) · Periodontology 2000 · doi:10.1111/prd.12170 · Cited by 479
The interface zone of inorganic implantsIn vivo: Titanium implants in bone
Albrektsson, T., Brånemark, P.-I., Hansson, H.-A., Kasemo, B., Larsson, K., Lundström, I., McQueen, D. H., & Skalak, R. (1983) · Annals of Biomedical Engineering · doi:10.1007/bf02363944 · Cited by 436
Self-citationPersistent Acute Inflammation at the Implant-Abutment Interface
Broggini, N., McManus, L. M., Hermann, J. S., Medina, R. U., Oates, T. W., Schenk, R. K., Buser, D., Mellonig, J. T., & Cochran, D. L. (2003) · Journal of Dental Research · doi:10.1177/154405910308200316 · Cited by 427
Biomechanical factors affecting the bone-dental implant interface
Brunski, J. B. (1992) · Clinical Materials · doi:10.1016/0267-6605(92)90049-y · Cited by 407
The Impact of Dental Implant Surface Modifications on Osseointegration and Biofilm Formation
Kligman, S., Ren, Z., Chung, C.-H., Perillo, M. A., Chang, Y.-C., Koo, H., Zheng, Z., & Li, C. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10081641 · Cited by 387
Soft Tissue Reactions to Non‐Submerged Unloaded Titanium Implants in Beagle Dogs
Buser, D., Weber, H. P., Donath, K., Fiorellini, J. P., Paquette, D. W., & Williams, R. C. (1992) · Journal of Periodontology · doi:10.1902/jop.1992.63.3.225 · Cited by 383
Are ceramic implants a viable alternative to titanium implants? A systematic literature review
Andreiotelli, M., Wenz, H. J., & Kohal, R. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01785.x · Cited by 380
Physico-chemical considerations of titanium as a biomaterial
Tengvall, P., & Lundström, I. (1992) · Clinical Materials · doi:10.1016/0267-6605(92)90056-y · Cited by 373
State-of-the-art on cone beam CT imaging for preoperative planning of implant placement
Guerrero, M. E., Jacobs, R., Loubele, M., Schutyser, F., Suetens, P., & van Steenberghe, D. (2006) · Clinical Oral Investigations · doi:10.1007/s00784-005-0031-2 · Cited by 371
Basic research methods and current trends of dental implant surfaces
Coelho, P. G., Granjeiro, J. M., Romanos, G. E., Suzuki, M., Silva, N. R. F., Cardaropoli, G., Thompson, V. P., & Lemons, J. E. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31264 · Cited by 359
PEEK Dental Implants: A Review of the Literature
Schwitalla, A., & Müller, W.-D. (2013) · Journal of Oral Implantology · doi:10.1563/aaid-joi-d-11-00002 · Cited by 340
Biomaterial and antibiotic strategies for peri‐implantitis: A review
Norowski, P. A., & Bumgardner, J. D. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31152 · Cited by 339
A review of plasma-assisted methods for calcium phosphate-based coatings fabrication
Surmenev, R. A. (2012) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2011.11.002 · Cited by 332
A Comparison of Endosseous Dental Implant Surfaces
Cochran, D. L. (1999) · Journal of Periodontology · doi:10.1902/jop.1999.70.12.1523 · Cited by 329
Zirconia surface modifications for implant dentistry
Schünemann, F. H., Galárraga-Vinueza, M. E., Magini, R., Fredel, M., Silva, F., Souza, J. C. M., Zhang, Y., & Henriques, B. (2019) · Materials Science and Engineering: C · doi:10.1016/j.msec.2019.01.062 · Cited by 309
Schenk, R. K., & Buser, D. (1998) · Periodontology 2000 · doi:10.1111/j.1600-0757.1998.tb00120.x · Cited by 300
Zirconia dental implants: where are we now, and where are we heading?
Cionca, N., Hashim, D., & Mombelli, A. (2017) · Periodontology 2000 · doi:10.1111/prd.12180 · Cited by 300
Implant surface characteristics and their effect on osseointegration
Barfeie, A., Wilson, J., & Rees, J. (2015) · British Dental Journal · doi:10.1038/sj.bdj.2015.171 · Cited by 292
Anchorage of TiO2‐blasted, HA‐coated, and machined implants: An experimental study with rabbits
Gotfredson, K., Wennerberg, A., Johansson, C., Skovgaard, L. T., & Hjørting‐Hansen, E. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820291009 · Cited by 284
Duong, H., Roccuzzo, A., Stähli, A., Salvi, G. E., Lang, N. P., & Sculean, A. (2022) · Periodontology 2000 · doi:10.1111/prd.12419 · Cited by 283
Bone-metal interface in osseointegration
Albrektsson, T., & Jacobsson, M. (1987) · The Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(87)90344-1 · Cited by 264
Bornstein, M. M., Schmid, B., Belser, U. C., Lussi, A., & Buser, D. (2005) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2005.01209.x · Cited by 257
Evolving strategies for preventing biofilm on implantable materials
Shah, S. R., Tatara, A. M., D'Souza, R. N., Mikos, A. G., & Kasper, F. K. (2013) · Materials Today · doi:10.1016/j.mattod.2013.05.003 · Cited by 99
Alrabeah, G. O., Brett, P., Knowles, J. C., & Petridis, H. (2017) · Journal of Dentistry · doi:10.1016/j.jdent.2017.08.002 · Cited by 85
A Magnesium-Incorporated Nanoporous Titanium Coating for Rapid Osseointegration
Li, X., Wang, M., Zhang, W., Bai, Y., Liu, Y., Meng, J., & Zhang, L. (2020) · International Journal of Nanomedicine · doi:10.2147/ijn.s255486 · Cited by 58
Effects of polydopamine coating on the bioactivity of titanium for dental implants
Lee, J.-J., Park, I.-S., Shin, G.-S., Lyu, S.-K., Ahn, S.-G., Bae, T.-S., & Lee, M.-H. (2014) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-014-0515-6 · Cited by 30
Montero, J., Guadilla, Y., Flores, J., Pardal-Peláez, B., Quispe-López, N., Gómez-Polo, C., & Dib, A. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10194589 · Cited by 18
Waßmann, M., Winkel, A., Haak, K., Dempwolf, W., Stiesch, M., & Menzel, H. (2016) · Journal of Biomaterials Science Polymer Edition · doi:10.1080/09205063.2016.1214001 · Cited by 15
Clarke, L., Bowyer, L., Noone, J., Stevens, C., Yates, J., & Ashley, M. (2020) · Oral Surgery · doi:10.1111/ors.12479 · Cited by 7
Metadata
- Authors
- Brånemark, P.-I., Breine, U., Adell, R., Hansson, B. O., Lindström, J., & Ohlsson, Å.
- Venue
- Scandinavian Journal of Plastic and Reconstructive Surgery
- Publisher
- Informa UK Limited
- Published
- 1969-01
- Volume
- 3
- Issue
- 2
- Pages
- 81-100
- ISSN
- 0036-5556 (ISSN-L)
- OpenAlex
- W2056773589
- Cited by
- 1,811
- References
- 1
- FWCI
- 2.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.