Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology
Open accessThe DOI matches its Crossref record; 231 of the 246 references it cites were found in a registry or an index; 263 of the 429 sources its claims cite were checked for support.
Abstract
A systematic literature review including 189 articles on AI applications in obstetrics and gynecology ultrasound imaging, with 148 focused on obstetrics.
Overview
CoChat Summary
## TL;DR
This systematic review mapped published AI applications in obstetric and gynecologic ultrasound and found far more studies in obstetrics than gynecology: 148 versus 41, out of 189 included articles. The paper concludes that AI can reduce exam time, workload, and variability, but most studies remain technical and have limited clinical applicability.
## Key findings
- The review included 189 articles published from 1994 to 2023; 148 focused on obstetrics and 41 on gynecology.
- In obstetrics, the most represented topics were fetal biometry, fetal echocardiography, neurosonography, gestational age estimation, and workflow analysis; in gynecology, major topics included adnexal masses, breast masses, endometrium, and pelvic floor.
- AI-assisted ultrasound was repeatedly reported to reduce examination time; for pelvic floor studies, reported time dropped from up to 15 minutes to 1.27 seconds.
- For gestational age estimation, the review reports high accuracy with an error of 3.9 to 5 days in some models, and for breast/ovarian mass work, some AI systems matched or outperformed human readers in the cited studies.
## Methods
- The authors conducted a systematic literature review in line with PRISMA, and prospectively registered it in PROSPERO (CRD42023434218).
- They searched PubMed and the Cochrane Library on 14 May 2023, screening English- and German-language records using a PICOS-based approach.
- Inclusion focused on studies using AI with ultrasound in obstetrics or gynecology; studies without AI or US, outside OB/GYN, or using only ultrasound-derived measurements rather than images were excluded.
## Limitations
- The paper states that many AI models still require expert input for image acquisition, ROI selection, and interpretation, and that most studies are technical/preliminary rather than clinically validated.
- The review notes that its search query included the extra keyword “pregnancy,” which likely biased retrieval toward obstetric studies. *(stated in the paper)*
- It also states that including many engineering-literature studies may limit clinical applicability, and that most models lack external validation, real-time use, and testing on pathologic or heterogeneous data. *(stated in the paper)*
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
175 Valid · 12 Not valid · 62 Not checked · 80 Own results and interpretations
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“slow processing times [35,43]”
§ Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology > 3. Results > 3.2. Applications in Obstetrics
What the sources say
- Disputedcites [35] Heuvel T.L.v.D. Petros H. Santini S. de Korte C.L. van Ginneken B. Automated Fetal Head Detection and Circumference Estimation from Free-Hand Ultrasound Sweeps Using Deep Learning in Resource-Limited Countries Ultrasound Med. Biol. 2019 45 773 785 10.1016/j.ultrasmedbio.2018.09.015 30573305 sourceExperimental — accuracy not yet measured
The “Deployment on low-cost hardware” section says frame classification is fast enough for real-time computation on the study’s training hardware, rather than identifying slow AI processing as a limitation. The “Improvements” section identifies a different delay: the ultrasound device took one minute to save each sweep. (LLM, conf=0.84)
Checked by a reasoning model — may be wrong.
- Not checked — no full text of the sourcecites [43] Chen H. Ni D. Qin J. Li S. Yang X. Wang T. Heng P.A. Standard Plane Localization in Fetal Ultrasound via Domain Transferred Deep Neural Networks IEEE J. Biomed. Health Inform. 2015 19 1627 1636 10.1109/JBHI.2015.2425041 25910262 source
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Disputed
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“The image quality assessment of whether a standard plane was correctly acquired, either by human operators or by automated extraction from 3D images, was effectively performed by models developed by the research groups of Lin et al. [90], Yaqub et al. [91], and Skelton et al. [92].”
§ Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology > 3. Results > 3.2. Applications in Obstetrics
What the sources say
- Not checked — no full text of the sourcecites [90] Lin Z. Li S. Ni D. Liao Y. Wen H. Du J. Chen S. Wang T. Lei B. Multi-task learning for quality assessment of fetal head ultrasound images Med. Image Anal. 2019 58 101548 10.1016/j.media.2019.101548 31525671 source
- Not checked — no full text of the sourcecites [91] Yaqub M. Kelly B. Papageorghiou A.T. Noble J.A. A Deep Learning Solution for Automatic Fetal Neurosonographic Diagnostic Plane Verification Using Clinical Standard Constraints Ultrasound Med. Biol. 2017 43 2925 2933 10.1016/j.ultrasmedbio.2017.07.013 28958729 source
- Disputedcites [92] Skelton E. Matthew J. Li Y. Khanal B. Martinez J.C. Toussaint N. Gupta C. Knight C. Kainz B. Hajnal J. Towards automated extraction of 2D standard fetal head planes from 3D ultrasound acquisitions: A clinical evaluation and quality assessment comparison Radiography 2021 27 519 526 10.1016/j.radi.2020.11.006 33272825 PMC8052189 sourceExperimental — accuracy not yet measured
The Methods (Quality assessment; page unavailable) state that two human observers assessed whether each plane was adequate. The model automatically extracted planes from 3D images; it did not perform the image-quality assessment attributed to it. (LLM, conf=0.88)
Checked by a reasoning model — may be wrong.
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
Every source the paper cites for this claim was checked and supports it.
In the paper
“However, US imaging has limitations regarding its comparability and reproducibility.”
§ Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology > 1. Introduction
What the sources say
- Supportedcites [4] Diniz P.H.B. Yin Y. Collins S. Deep Learning Strategies for Ultrasound in Pregnancy EMJ Reprod. Health 2020 6 73 80 10.33590/emjreprohealth/20-00100 PMC7590498 33123376 source
The Introduction says ultrasound has high inter- and intra-observer variability across different manufacturers’ machines. That directly supports the paraphrased limitations in reproducibility and comparability. (LLM, conf=0.91)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“the possibility of real-time applicability [15,25,32,33]”
§ Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology > 3. Results > 3.2. Applications in Obstetrics
What the sources say
- Supportedcites [15] Baumgartner C.F. Kamnitsas K. Matthew J. Fletcher T.P. Smith S. Koch L.M. Kainz B. Rueckert D. SonoNet: Real-Time Detection and Localisation of Fetal Standard Scan Planes in Freehand Ultrasound IEEE Trans. Med. Imaging 2017 36 2204 2215 10.1109/TMI.2017.2712367 28708546 PMC6051487 source
The Abstract states that SonoNet’s convolutional network is designed to operate in real time when detecting fetal standard scan planes and reports a real-time detection experiment. The Introduction (Contributions) also says the system can provide real-time feedback to the operator. (LLM, conf=0.93)
- Supportedcites [25] Płotka S. Klasa A. Lisowska A. Seliga-Siwecka J. Lipa M. Trzciński T. Sitek A. Deep learning fetal ultrasound video model match human observers in biometric measurements Phys. Med. Biol. 2022 67 045013 10.1088/1361-6560/ac4d85 35051921 source
The Discussion says the automatic approach could be used in real time during routine fetal ultrasound examinations to help identify standard planes. It also notes that this would require installation on the ultrasound device and integration into the workflow; the claim is about the possibility, not an already deployed capability. (LLM, conf=0.93)
- Not checked — no full text of the sourcecites [32] Carneiro G. Georgescu B. Good S. Comaniciu D. Detection and Measurement of Fetal Anatomies from Ultrasound Images using a Constrained Probabilistic Boosting Tree IEEE Trans. Med. Imaging 2008 27 1342 1355 10.1109/TMI.2008.928917 18753047 source
- Not checked — no full text of the sourcecites [33] Luo D. Wen H. Peng G. Lin Y. Liang M. Liao Y. Qin Y. Zeng Q. Dang J. Li S. A Prenatal Ultrasound Scanning Approach: One-Touch Technique in Second and Third Trimesters Ultrasound Med. Biol. 2021 47 2258 2265 10.1016/j.ultrasmedbio.2021.04.020 34059375 source
hedgedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“the application of a lightweight algorithm in point-of-care devices [18,34,37]”
§ Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology > 3. Results > 3.2. Applications in Obstetrics
What the sources say
- Not checked — no full text of the sourcecites [18] Zeng W. Luo J. Cheng J. Lu Y. Efficient fetal ultrasound image segmentation for automatic head circumference measurement using a lightweight deep convolutional neural network Med. Phys. 2022 49 5081 5092 10.1002/mp.15700 35536111 source
- Partly supportedcites [34] Zeng Y. Tsui P.-H. Wu W. Zhou Z. Wu S. Fetal Ultrasound Image Segmentation for Automatic Head Circumference Biometry Using Deeply Supervised Attention-Gated V-Net J. Digit. Imaging 2021 34 134 148 10.1007/s10278-020-00410-5 33483862 PMC7887128 sourceExperimental — accuracy not yet measured
The Discussion (page unavailable) describes point-of-care use as a potential application and reports a 6.3 ms execution time on a computer. The Introduction (page unavailable) says the attention modules add few parameters at low computational cost. The paper does not report applying the algorithm on point-of-care devices or using it to acquire standard planes; it studies head segmentation and circumference measurement from existing images. (LLM, conf=0.85)
- Not checked — no full text of the sourcecites [37] Yang C. Yang Z. Liao S. Guo J. Yin S. Liu C. Kang Y. A new approach to automatic measure fetal head circumference in ultrasound images using convolutional neural networks Comput. Biol. Med. 2022 147 105801 10.1016/j.compbiomed.2022.105801 35785663 source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
198 more claims · 120 with their cited sources checked
Create a free account to see all 329 claims and every source verdict.
- It may state two separate claims as one. 69
- Probably not a substantial claim. 69
- The quote only partly states this claim. 3
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Self-check results appear here once an independent check has confirmed them.
Cited works that were retracted
Works this paper cites that were later retracted, from the retraction notices publishers deposit. Major when the notice came out before this paper was published.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
“Zhang Y. Hou J. Wang Q. Hou A. Liu Y. Application of Transfer Learning and Feature Fusion Algorithms to Improve the Identification and Prediction Efficiency of Premature Ovarian Failure J. Healthc. Eng. 2022 2022 3269692 10.1155/2022/3269692 35388326 PMC8977322”
Cited work 10.1155/2022/3269692 · retracted 2023-10-11 · notice 10.1155/2023/9850459 · this paper published 2023-10-29
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
“Liu S. Sun Y. Luo N. Doppler Ultrasound Imaging Combined with Fetal Heart Detection in Predicting Fetal Distress in Pregnancy-Induced Hypertension under the Guidance of Artificial Intelligence Algorithm J. Healthc. Eng. 2021 2021 4405189 10.1155/2021/4405189 34659686 PMC8519722”
Cited work 10.1155/2021/4405189 · retracted 2023-10-11 · notice 10.1155/2023/9762610 · this paper published 2023-10-29
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
“The model of He et al. addressed the challenge of the identification and classification of intrauterine pregnancy residues that had the potential to reduce associated complications and improve surgical outcomes of curettages [167].”
Cited work 10.1155/2022/9937051 · retracted 2023-10-18 · notice 10.1155/2023/9780604 · this paper published 2023-10-29
A note, not an issue: for example, a cited work that was retracted only after this paper was published, which its authors could not have known.
In the paper
“These algorithms may improve medical diagnosis and potentially reduce clinical workload by replacing the sonographer’s manual tracing [168].”
Cited work 10.1155/2022/4010339 · retracted 2023-12-06 · notice 10.1155/2023/9792545 · this paper published 2023-10-29
A note, not an issue: for example, a cited work that was retracted only after this paper was published, which its authors could not have known.
In the paper
“Han, G., Jin, T., Zhang, L., Guo, C., Gui, H., Na, R., Wang, X., and Bai, H. (2022). Adoption of Compound Echocardiography under Artificial Intelligence Algorithm in Fetal Congenial Heart Disease Screening during Gestation. Appl. Bionics Biomech., 2022.”
Cited work 10.1155/2022/6410103 · retracted 2023-11-29 · notice 10.1155/2023/9814523 · this paper published 2023-10-29
A note, not an issue: for example, a cited work that was retracted only after this paper was published, which its authors could not have known.
In the paper
“Lastly, the studies of Burgos-Artizzu et al. and Sreelakshmy et al. portrayed AI methods for the estimation of GA through an analysis of transthalamic axial planes or cerebellum measurements [95,96].”
Cited work 10.1155/2022/8342767 · retracted 2023-12-29 · notice 10.1155/2023/9852080 · this paper published 2023-10-29
Citations
Cites
6 retracted
Items 201–231 of 231
Task model-specific operator skill assessment in routine fetal ultrasound scanning
Wang, Y., Yang, Q., Drukker, L., Papageorghiou, A., Hu, Y., & Noble, J. A. (2022) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-022-02642-y · Cited by 12
Artificial intelligence enhanced ultrasound (AI-US) in a severe obese parturient: A case report
Compagnone, C., Borrini, G., Calabrese, A., Taddei, M., Bellini, V., & Bignami, E. (2022) · The Ultrasound Journal · doi:10.1186/s13089-022-00283-5 · Cited by 12
Veronese, P., Guariento, A., Cattapan, C., Fedrigo, M., Gervasi, M. T., Angelini, A., Riva, A., & Vida, V. (2023) · Diagnostics · doi:10.3390/diagnostics13030456 · Cited by 12 · cited 2×
“Four of the included studies investigated the application of fetal intelligent navigation echocardiography (FINE) as a reliable technique that enabled the automated acquisition of nine standard echocardiographic views from specific 4D volumes of a single cardiac cycle in motion [51–54].”
BackgroundMethodDetermination of Fetal Left Ventricular Volume Based on Two-Dimensional Echocardiography
Yu, L., Guo, Y., Wang, Y., Yu, J., & Chen, P. (2017) · Journal of Healthcare Engineering · doi:10.1155/2017/4797315 · Cited by 11 · cited 1×
“Yu et al. automatically measured left ventricular volume in 2D US images [64], Herling et al. analyzed the automated measurement of fetal atrioventricular plane displacement in US videos of cardiac cycles using color tissue Doppler [65], and Scharf et al. evaluated the automated assessment of the…”
MethodCengizler, Ç., Ün, M. K., & Büyükkurt, S. (2020) · Scientific Reports · doi:10.1038/s41598-020-66468-x · Cited by 11
Skelton, E., Matthew, J., Li, Y., Khanal, B., Cerrolaza Martinez, J. J., Toussaint, N., Gupta, C., Knight, C., Kainz, B., Hajnal, J. V., et al. (2021) · Radiography · doi:10.1016/j.radi.2020.11.006 · Cited by 11 · cited 1×
“The image quality assessment of whether a standard plane was correctly acquired, either by human operators or by automated extraction from 3D images, was effectively performed by models developed by the research groups of Lin et al. [90], Yaqub et al. [91], and Skelton et al. [92].”
MethodSchwartz, N., Oguz, I., Wang, J., Pouch, A., Yushkevich, N., Parameshwaran, S., Gee, J., Yushkevich, P., & Oguz, B. (2022) · Journal of Ultrasound in Medicine · doi:10.1002/jum.15835 · Cited by 11
Beksaç, M. S., Odçık ın, Z., Egemena, A., & Karakaş, Ü. (1996) · Technology and Health Care · doi:10.3233/thc-1996-4209 · Cited by 11
Singh, V. K., Yousef Kalafi, E., Cheah, E., Wang, S., Wang, J., Ozturk, A., Li, Q., Eldar, Y. C., Samir, A. E., & Kumar, V. (2022) · Diagnostics · doi:10.3390/diagnostics12123213 · Cited by 11
Asadpour, V., Puttock, E. J., Getahun, D., Fassett, M. J., & Xie, F. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e13577 · Cited by 11
A Prenatal Ultrasound Scanning Approach: One-Touch Technique in Second and Third Trimesters
Luo, D., Wen, H., Peng, G., Lin, Y., Liang, M., Liao, Y., Qin, Y., Zeng, Q., Dang, J., & Li, S. (2021) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2021.04.020 · Cited by 10 · cited 4×
“Most studies reported the combined analysis of various standard planes (13 studies, [15,17,23–33]) or exclusively presented an algorithm for the analysis of HC (9 studies, [18,22,34–40]), AC (4 studies, [21,41–43]) or femur length (1 study, [44]).”
BackgroundMethodInfluentialYu, L., & Qing, X. (2022) · Computational and Mathematical Methods in Medicine · doi:10.1155/2022/2645607 · Cited by 10 · cited 1×
“In total, 11 articles were summarized in this section, including the topics of endometriosis [216,217], premature ovarian failure [218,219], uterine fibroids [220,221], follicle tracking [222,223], and ectopic pregnancies [224,225].”
BackgroundDu, Y., Jiao, J., Ji, C., Li, M., Guo, Y., Wang, Y., Zhou, J., & Ren, Y. (2022) · Scientific Reports · doi:10.1038/s41598-022-17129-8 · Cited by 10 · cited 1×
“The study of Bonet-Carne et al. and a further study of Du et al. showed that automated fetal lung ultrasound was able to accurately predict neonatal respiratory morbidity [164,165].”
Sun, H., Jiao, J., Ren, Y., Guo, Y., & Wang, Y. (2023) · Pregnancy Hypertension · doi:10.1016/j.preghy.2022.12.003 · Cited by 10 · cited 1×
“Early and small changes in placental tissue texture were detected by Gupta et al. and Sun et al. through using AI-assisted US and microvascular Doppler imaging in women with hypertensive disorders of pregnancy [118,119] and gestational diabetes [120].”
MethodWu, M., Fraser, R. F., & Chen, C. W. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.832548 · Cited by 9 · cited 2×
“The early study of Wu et al. proposed a tool for preterm labor prediction by using computer-assisted measurement of the cervix on transvaginal US images to overcome the issues of poor reproducibility and sonographer dependency on manual cervical length measurements [166].”
MethodPradipta, G. A., Wardoyo, R., Musdholifah, A., & Sanjaya, I. N. H. (2022) · Health Informatics Journal · doi:10.1177/14604582221084211 · Cited by 9
Yang, X., Chen, Z., & Jia, X. (2022) · Computational and Mathematical Methods in Medicine · doi:10.1155/2022/3452176 · Cited by 9 · cited 1×
“Yang et al., therefore, investigated the predictive role of a scoring system for the occurrence of pernicious placenta previa [121], while the research group of Asadpour et al. reported a method for identifying placental abruption [122].”
MethodSong, J., Liu, J., Liu, L., Jiang, Y., Zheng, H., Ke, H., Yang, L., & Zhang, Z. (2022) · Journal of Clinical Ultrasound · doi:10.1002/jcu.23236 · Cited by 9
Beksaç, M. S., Egemen, A., izzetoǵlu, K., Ergün, G., & Erkmen, A. M. (1996) · European Journal of Radiology · doi:10.1016/0720-048x(96)01067-4 · Cited by 8
Xu, Y., Lee, L. H., Drukker, L., Yaqub, M., Papageorghiou, A. T., & Noble, A. J. (2020) · Journal of medical imaging · doi:10.1117/1.jmi.7.5.057001 · Cited by 8 · cited 2×
“Xu et al. presented an AI method for authenti-cally simulating third-trimester images from second-trimester images for deep-learning researchers with restricted access to third-trimester images [84].”
BackgroundMethodAutomated multi-beat tissue Doppler echocardiography analysis using deep neural networks
Lane, E. S., Jevsikov, J., Shun-Shin, M. J., Dhutia, N. M., Matoorian, N., Cole, G. D., Francis, D. P., & Zolgharni, M. (2023) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-022-02753-3 · Cited by 8 · cited 1×
“Not only the detection of structural abnormalities in case of CHD, but also cardiac function analysis, is a future topic of AI applications in fetal echocardiography using tissue Doppler US, which can be relevant, e.g., for fetuses diagnosed with hypoplastic left heart syndrome [74–76].”
Early sonographic evaluation of the placenta in cases with IUGR: A pilot study
Walter, A., Böckenhoff, P., Geipel, A., Gembruch, U., & Engels, A. C. (2020) · Archives of Gynecology and Obstetrics · doi:10.1007/s00404-020-05601-7 · Cited by 7 · cited 1×
“For example, research has shown a correlation between early placental sonographic echogenicity and the prediction of intrauterine growth restriction [107].”
MethodSelf-citationSun, H., Jiao, J., Ren, Y., Guo, Y., & Wang, Y. (2022) · Journal of Clinical Ultrasound · doi:10.1002/jcu.23233 · Cited by 7 · cited 1×
“Early and small changes in placental tissue texture were detected by Gupta et al. and Sun et al. through using AI-assisted US and microvascular Doppler imaging in women with hypertensive disorders of pregnancy [118,119] and gestational diabetes [120].”
MethodHuang, X., Qiu, Y., Bao, F., Wang, J., Lin, C., Lin, Y., Wu, J., & Yang, H. (2023) · Frontiers in Public Health · doi:10.3389/fpubh.2022.1098639 · Cited by 6
Fetal brain activity and the free energy principle
Miyagi, Y., Hata, T., & Miyake, T. (2023) · Journal of Perinatal Medicine · doi:10.1515/jpm-2023-0092 · Cited by 6 · cited 1×
“Miyagi et al. proposed an AI classifier analyzing 4D US volumes to assess fetal facial expressions and classify them into different categories [102,103], and showed that the identification of dense and sparse states of brain activity is possible [104].”
BackgroundInterpretation of Doppler blood flow velocity waveforms using neural networks.
(1994) · PubMed Central · Cited by 5
Zhu, Y., Zhang, J., Ji, Z., Liu, W., Li, M., Xia, E., Zhang, J., & Wang, J. (2022) · Computational and Mathematical Methods in Medicine · doi:10.1155/2022/1116332 · Cited by 5 · cited 3×
“Two studies used 3D US images [211,212], two 2D [213–215], two of them derived 2D images from a 3D/4D data set [214,215], and one did not specify the type of image [210].”
BackgroundMethodSriraam, N., Punyaprabha, V., Sushma, T. V., & Suresh, S. (2023) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-023-02814-1 · Cited by 5 · cited 2×
“As a solution to this issue and an emerging research focus, the detection of the fetal heart as a ROI in US images can be performed by AI models [72,73].”
BackgroundFive-dimensional ultrasound system for soft tissue visualization
Deshmukh, N. P., Caban, J. J., Taylor, R. H., Hager, G. D., & Boctor, E. M. (2015) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-015-1277-z · Cited by 4 · cited 1×
“While 4D technology extends the 3D view of the scanned object with a time frame, enabling motion visualization, or so-called ‘real-time 3D’ [9], the term 5D is uncommonly used to describe AI-assisted US imaging including image enhancement processing or automated calculations [10,11].”
Introduction to Artificial Intelligence in Ultrasound Imaging in Obstetrics and Gynecology
Drukker, L., Noble, J. A., & Papageorghiou, A. T. (2021) · Obstetrical & Gynecological Survey · doi:10.1097/ogx.0000000000000910 · Cited by 2
Yu, Y., Chen, Z., Zhuang, Y., Yi, H., Han, L., Chen, K., & Lin, J. (2022) · Journal of X-Ray Science and Technology · doi:10.3233/xst-221278 · Cited by 2 · cited 2×
“The establishment of a plane localization system as a 3D reference space for locating 2D planes was proposed by Yeung et [78,80,82,83].”
BackgroundMethod
Cited by
Guillen-Grima, F., Guillen-Aguinaga, S., Guillen-Aguinaga, L., Alas-Brun, R., Onambele, L., Ortega, W., Montejo, R., Aguinaga-Ontoso, E., Barach, P., & Aguinaga-Ontoso, I. (2023) · Clinics and Practice · doi:10.3390/clinpract13060130 · Cited by 72
Progress in the Application of Artificial Intelligence in Ultrasound-Assisted Medical Diagnosis
Li, Y., Li, Q., Fu, K., Zhou, X., & Zhang, K. (2025) · Bioengineering · doi:10.3390/bioengineering12030288 · Cited by 85
“This evolution is effectively dismantling traditional limitations in ultrasound examinations, improving imaging quality, optimizing procedural workflows, and advancing the field of ultrasound medicine toward precision healthcare.”
Stringer, J. S. A., Pokaprakarn, T., Prieto, J. C., Vwalika, B., Chari, S. V., Sindano, N., Freeman, B. L., Sikapande, B., Davis, N. M., Sebastião, Y. V., et al. (2024) · JAMA · doi:10.1001/jama.2024.10770 · Cited by 70
Brandão, M., Mendes, F., Martins, M., Cardoso, P., Macedo, G., Mascarenhas, T., & Mascarenhas, M. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13041061 · Cited by 48
“Nevertheless, there is a need to understand the limitations of the available clinical imaging methods, namely clinician workload and intra and interobserver variability, and AI has the potential to overcome these limitations while increasing diagnostic accuracy [23].”
BackgroundQuality of ChatGPT-Generated Therapy Recommendations for Breast Cancer Treatment in Gynecology
Stalp, J. L., Denecke, A., Jentschke, M., Hillemanns, P., & Klapdor, R. (2024) · Current Oncology · doi:10.3390/curroncol31070284 · Cited by 27
“Since this research is often lacking clinical applicability [2], these systems are not implemented in daily medical treatment routines, therapy recommendations or patient care in Germany.”
BackgroundMethod
Metadata
- Authors
- Jost, E., Kosian, P., Jimenez Cruz, J., Albarqouni, S., Gembruch, U., Strizek, B., & Recker, F.
- Affiliations
- University Hospital Bonn (DE)
- Department of Obstetrics and Gynecology, University Hospital Bonn, Venusberg Campus 1, 53127 Bonn, Germany
- Corresponding author
- Recker, Florian
- ORCID
- Venue
- Journal of Clinical Medicine
- Publisher
- MDPI AG
- Published
- 2023-10-29
- Volume
- 12
- Issue
- 21
- Pages
- 6833
- ISSN
- 2077-0383 (ISSN-L)
- PMC
- PMC10649694
- OpenAlex
- W4388105557
- Cited by
- 44
- References
- 246
- Citations by year
- 2026: 7 · 2025: 16 · 2024: 20 · 2023: 1
- FWCI
- 0.52
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Journal of Clinical Medicine (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by-nc-sa)
- PubMed (publishedVersion)
- bonndoc (University of Bonn) (submittedVersion, cc-by)
- PuSH - Publication Server of Helmholtz Zentrum München (submittedVersion)
- Funders
- Open Access Publication Fund of the University of Bonn
- Topics
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
- Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
- Keywords
- artificial intelligence, ultrasonography, obstetrics, gynecology, anatomical measurements, pathology detection, fetal biometry, echocardiography, neurosonography, adnexal mass, breast mass, endometrial assessment, pelvic floor assessment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.