CoChat

Deep Eutectic Solvent-Based Microextraction of Lead(II) Traces from Water and Aqueous Extracts before FAAS Measurements

Open access

The DOI matches its Crossref record; 54 of the 57 references it cites were found in a registry or an index; 7 of the 34 sources its claims cite were checked for support.

Abstract

Microextraction procedures for the separation of Pb(II) from water and food samples extracts were developed. A deep eutectic solvent composed of α-benzoin oxime and iron(III) chloride dissolved in phenol was applied as a phase separator support. In addition, this deep eutectic mixture worked as an efficient extractor of Pb(II). The developed microextraction process showed a high ability to tolerate the common coexisting ions in the real samples. The optimum conditions for quantitative recoveries of Pb(II) from aqueous extracts were at pH 2.0, conducted by adding 150 µL from the deep eutectic solvent. The quantitative recoveries were obtained with various initial sample volumes up to 30 mL. Limits of detection and limits of quantification of 0.008 and 0.025 µg L−1 were achieved with a relative standard deviation (RSD%) of 2.9, which indicates the accuracy and sensitivity of the developed procedure. Recoveries from the reference materials, including TMDA 64.2, TMDA 53.3, and NCSDC-73349, were 100%, 97%, and 102%, respectively. Real samples, such as tap, lake, and river water, as well as food samples, including salted peanuts, chickpeas, roasted yellow corn, pistachios, and almonds, were successfully applied for Pb(II) analysis by atomic absorption spectroscopy (AAS) after applying the developed deep eutectic solvent-based microextraction procedures.

Overview

CoChat Summary

TL;DR

A deep eutectic solvent made of α-benzoin oxime, iron(III) chloride, and phenol was used for microextraction of Pb(II) from water and food extracts before FAAS. The method achieved LOD 0.008 µg L−1, LOQ 0.025 µg L−1, RSD 2.9%, and quantitative recovery under optimized conditions.

Key findings

  • Optimum recovery occurred at pH 2.0 with 150 µL of deep eutectic solvent; 50–100 µL gave approximately 80% recovery, while at least 150 µL gave approximately 100%.
  • LOD and LOQ were 0.008 and 0.025 µg L−1, respectively, with RSD 2.9%; the preconcentration factor was 60 using sample volumes up to 30 mL and a final extracted volume of 500 µL.
  • Certified reference material recoveries were 100% for TMDA 64.2, 97% for TMDA 53.3, and 102% for NCSDC-73349.
  • Foreign ions gave recoveries of 94–103%; addition/recovery experiments gave 92–101% in the Results section, while the Conclusions state 92–106%.

Methods

  • The DES was prepared by mixing iron(III) chloride with phenol at a 1:5 molar ratio, warming at 50 °C for 10 min, stirring for 60 min at room temperature, then adding 0.01 g α-benzoin oxime and stirring another 60 min; melting point was 28.6 °C and viscosity was 47 cps.
  • Pb(II) samples were adjusted to pH 2, injected with approximately 150 µL DES, vortexed for 5 min, centrifuged for 12 min at 4000 rpm, and the remaining phase was dissolved in nitric acid to 500 µL for FAAS.
  • Validation used TMDA 64.2, TMDA 53.3, and NCSDC-73349; water samples were filtered through 0.45-µm filters and 10 mL was used, while food samples were digested from 1.0 g to 10 mL and 2 mL extract was used; spiking was tested at 0.5, 1.0, and 2.0 mg L−1 with three replicates.

Limitations

  • Not stated in the paper; there is no explicit limitations section.
  • Evident from the text: the addition/recovery range is reported inconsistently, with Results stating 92–101% and Conclusions stating 92–106%.
  • Evident from the text: the narrative does not report individual foreign-ion concentrations or full interference data, and real-sample validation is limited to the listed water and food samples and spiking levels.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.3390/molecules25204794

Cites

54 of 54 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Evaluation of pH for the recovery of Pb(II) by DES-ME (n = 3).
Figure 1 Evaluation of pH for the recovery of Pb(II) by DES-ME (n = 3).CC BY · PubMed Central
Figure 2 Optimization of the amount of the deep eutectic solvent for the recovery of Pb(II) by microextraction (n = 3).
Figure 2 Optimization of the amount of the deep eutectic solvent for the recovery of Pb(II) by microextraction (n = 3).CC BY · PubMed Central
Figure 3 Evaluation of the sample volume for the deep eutectic-based microextraction of Pb(II) (n = 3).
Figure 3 Evaluation of the sample volume for the deep eutectic-based microextraction of Pb(II) (n = 3).CC BY · PubMed Central

Verification

Claims the paper makes

1 Valid · 2 Not valid · 7 Not checked · 27 Own results and interpretations

21 more claims

Create a free account to see all 37 claims and to verify the 27 references still open.

See all claims — free account
  • Probably not a substantial claim. 7
  • It may state two separate claims as one. 4

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

2 of 2

Citations

Cites

Research works printed but not linked: 1

  1. (2019, December 19). The Health Effects of Environmental Lead Exposure: Closing Pandora’s Box-Behavioral Measures of Neurotoxicity-NCBI Bookshelf, Available online: https://www.ncbi.nlm.nih.gov/books/NBK234984/.

Cited by

See all 38

Metadata

Authors
Habila, M. A., AlMasoud, N., Alomar, T. S., AlOthman, Z. A., Yilmaz, E., & Soylak, M.
Affiliations
  • King Saud University (SA)
  • Princess Nourah bint Abdulrahman University (SA)
  • Department of Analytical Chemistry, Faculty of Pharmacy, Erciyes University, 38039 Kayseri, Turkey
  • Erciyes University (TR)
Corresponding author
  • Habila, Mohamed A.
  • Alomar, Taghrid S.
Venue
Molecules
Publisher
MDPI AG
Published
2020-10-19
Volume
25
Issue
20
Pages
4794
ISSN
1420-3049 (ISSN-L)
OpenAlex
W3093088910
Cited by
38
References
57
Citations by year
2026: 8 · 2025: 4 · 2024: 5 · 2023: 6 · 2022: 5 · 2021: 9 · 2020: 1
FWCI
2.72
Type
journal article
Language
en
Open access
Locations
  • Molecules (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
the deanship of scientific research at princess nourah bint abdulrahman university (the research groups program grant number RGP-1440-0023.)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Chemical Engineering › Filtration and Separation › Chemical and Physical Properties in Aqueous Solutions
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
Keywords
deep eutectic solvents, lead(II) determination, preconcentration, ferric chloride, phenols, water analysis, food samples, trace metal extraction
MeSH terms
Animals, Ferric Compounds, Food Contamination, Humans, Lead, Milk, Spectrophotometry, Atomic, Water, Water Pollutants, Chemical, Limit of Detection, Liquid Phase Microextraction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-09-30, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-09-30 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (qwen3.8-omni-flash and gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.