The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Simultaneous Monitoring of Sweat and Interstitial Fluid Using a Single Wearable Biosensor Platform
Open accessAbstract
The development of wearable biosensors for continuous noninvasive monitoring of target biomarkers is limited to assays of a single sampled biofluid. An example of simultaneous noninvasive sampling and analysis of two different biofluids using a single wearable epidermal platform is demonstrated here. The concept is successfully realized through sweat stimulation (via transdermal pilocarpine delivery) at an anode, alongside extraction of interstitial fluid (ISF) at a cathode. The system thus allows on‐demand, controlled sampling of the two epidermal biofluids at the same time, at two physically separate locations (on the same flexible platform) containing different electrochemical biosensors for monitoring the corresponding biomarkers. Such a dual biofluid sampling and analysis concept is implemented using a cost‐effective screen‐printing technique with body‐compliant temporary tattoo materials and conformal wireless readout circuits to enable real‐time measurement of biomarkers in the sampled epidermal biofluids. The performance of the developed wearable device is demonstrated by measuring sweat‐alcohol and ISF‐glucose in human subjects consuming food and alcoholic drinks. The different compositions of sweat and ISF with good correlations of their chemical constituents to their blood levels make the developed platform extremely attractive for enhancing the power and scope of next‐generation noninvasive epidermal biosensing systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Skin-like pressure and strain sensors based on transparent elastic films of carbon nanotubes
Lipomi, D. J., Vosgueritchian, M., Tee, B. C.-K., Hellstrom, S. L., Lee, J. A., Fox, C. H., & Bao, Z. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.184 · Cited by 3,188
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Gibson, L. E., & Cooke, R. E. (1959) · Pediatrics · doi:10.1542/peds.23.3.545 · Cited by 1,434
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Self-citationEmaminejad, S., Gao, W., Wu, E., Davies, Z. A., Yin Yin Nyein, H., Challa, S., Ryan, S. P., Fahad, H. M., Chen, K., Shahpar, Z., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701740114 · Cited by 839
Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700
Self-citationNoninvasive Alcohol Monitoring Using a Wearable Tattoo-Based Iontophoretic-Biosensing System
Kim, J., Jeerapan, I., Imani, S., Cho, T. N., Bandodkar, A., Cinti, S., Mercier, P. P., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00356 · Cited by 599
Self-citationWearable non-invasive epidermal glucose sensors: A review
Kim, J., Campbell, A. S., & Wang, J. (2018) · Talanta · doi:10.1016/j.talanta.2017.08.077 · Cited by 586
Self-citationNon-invasive glucose monitoring technology in diabetes management: A review
Vashist, S. K. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.043 · Cited by 575
Correlation Between Sweat Glucose and Blood Glucose in Subjects with Diabetes
Moyer, J., Wilson, D., Finkelshtein, I., Wong, B., & Potts, R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0262 · Cited by 570
Heart Rate Assessment Immediately after Birth
Phillipos, E., Solevåg, A. L., Pichler, G., Aziz, K., van Os, S., O''Reilly, M., Cheung, P.-Y., & Schmölzer, G. M. (2016) · Neonatology · doi:10.1159/000441940 · Cited by 531
Bandodkar, A. J., Molinnus, D., Mirza, O., Guinovart, T., Windmiller, J. R., Valdés-Ramírez, G., Andrade, F. J., Schöning, M. J., & Wang, J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.11.039 · Cited by 490
Self-citationSkin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring
Chen, Y., Lu, S., Zhang, S., Li, Y., Qu, Z., Chen, Y., Lu, B., Wang, X., & Feng, X. (2017) · Science Advances · doi:10.1126/sciadv.1701629 · Cited by 467
Tierney, M. J., Tamada, J. A., Potts, R. O., Jovanovic, L., & Garg, S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00189-0 · Cited by 390
Bandodkar, A. J., Jeerapan, I., You, J.-M., Nuñez-Flores, R., & Wang, J. (2016) · Nano Letters · doi:10.1021/acs.nanolett.5b04549 · Cited by 341
Self-citationHo, M. D., Ling, Y., Yap, L. W., Wang, Y., Dong, D., Zhao, Y., & Cheng, W. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201700845 · Cited by 296
Non‐invasive Analyte Access and Sensing through Eccrine Sweat: Challenges and Outlook circa 2016
Heikenfeld, J. (2016) · Electroanalysis · doi:10.1002/elan.201600018 · Cited by 294
Minimally Invasive Extraction of Dermal Interstitial Fluid for Glucose Monitoring Using Microneedles
Wang, P. M., Cornwell, M., & Prausnitz, M. R. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.131 · Cited by 267
Transdermal monitoring of glucose and other analytes using ultrasound
Kost, J., Mitragotri, S., Gabbay, R. A., Pishko, M., & Langer, R. (2000) · Nature Medicine · doi:10.1038/73213 · Cited by 253
Glucose monitoring by reverse iontophoresis
Potts, R. O., A. Tamada, J., & J. Tierney, M. (2002) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.210 · Cited by 243
Shin, K.-Y., Lee, J. S., & Jang, J. (2016) · Nano Energy · doi:10.1016/j.nanoen.2016.02.012 · Cited by 239
Transdermal iontophoresis: combination strategies to improve transdermal iontophoretic drug delivery
Wang, Y., Thakur, R., Fan, Q., & Michniak, B. (2005) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2004.12.008 · Cited by 236
Iontophoretic delivery of drugs: Fundamentals, developments and biomedical applications
Banga, A. K., & Chien, Y. W. (1988) · Journal of Controlled Release · doi:10.1016/0168-3659(88)90075-2 · Cited by 232
Hammond, K. B., Turcios, N. L., & Gibson, L. E. (1994) · The Journal of Pediatrics · doi:10.1016/s0022-3476(94)70314-0 · Cited by 178
Thennadil, S. N., Rennert, J. L., Wenzel, B. J., Hazen, K. H., Ruchti, T. L., & Block, M. B. (2001) · Diabetes Technology & Therapeutics · doi:10.1089/15209150152607132 · Cited by 166
A wearable conductivity sensor for wireless real-time sweat monitoring
Liu, G., Ho, C., Slappey, N., Zhou, Z., Snelgrove, S. E., Brown, M., Grabinski, A., Guo, X., Chen, Y., Miller, K., et al. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.12.034 · Cited by 158
Miao, F., Cheng, Y., He, Y., He, Q., & Li, Y. (2015) · Sensors · doi:10.3390/s150511465 · Cited by 143
Gamella, M., Campuzano, S., Manso, J., Rivera, G. G. D., López-Colino, F., Reviejo, A. J., & Pingarrón, J. M. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.09.020 · Cited by 140
Reverse Iontophoresis: Noninvasive Glucose Monitoring in Vivo in Humans
Rao, G. S., Guy, R. H., Glikfeld, P., LaCourse, W. R., Leung, L., Tamada, J. A., Potts, R. O., & Azimi, N. (1995) · Pharmaceutical Research · doi:10.1023/a:1016271301814 · Cited by 138
A realtime and continuous assessment of cortisol in ISF using electrochemical impedance spectroscopy
Venugopal, M., Arya, S. K., Chornokur, G., & Bhansali, S. (2011) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2011.04.028 · Cited by 100
A wearable potentiometric sensor with integrated salt bridge for sweat chloride measurement
Choi, D., Li, Y., Cutting, G. R., & Searson, P. C. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.04.129 · Cited by 86
Sweat Ethanol Concentrations are Highly Correlated with Co‐Existing Blood Values in Humans
Buono, M. J. (1999) · Experimental Physiology · doi:10.1111/j.1469-445x.1999.01798.x · Cited by 74
Towards blood free measurement of glucose and potassium in humans using reverse iontophoresis
McCormick, C., Heath, D., & Connolly, P. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.03.016 · Cited by 46
Studies of Ph of Sweat Produced by Different Forms of Stimulation*
Herrmann, F., & Mandol, L. (1955) · Journal of Investigative Dermatology · doi:10.1038/jid.1955.36 · Cited by 45
Incidence of Severe Hypoglycemia and Its Causes in Insulin‐treated Diabetics
NILSSON, A., Tideholm, B., KALÉN, J., & Katzman, P. (1988) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1988.tb19370.x · Cited by 40
Woderer, S., Henninger, N., Garthe, C.-D., Klötzer, H.-M., Hajnsek, M., Kamecke, U., Gretz, N., Kraenzlin, B., & Pill, J. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.08.016 · Cited by 33
Varadharaj, E. K., & Nagaraju, J. (2016) · Journal of The Electrochemical Society · doi:10.1149/2.0751607jes · Cited by 29
Cited by
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Self-citationYang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Self-citationEnd-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
Lim, H., Kim, H. S., Qazi, R., Kwon, Y., Jeong, J., & Yeo, W. (2020) · Advanced Materials · doi:10.1002/adma.201901924 · Cited by 1,002
Metadata
- Authors
- Kim, J., Sempionatto, J. R., Imani, S., Hartel, M. C., Barfidokht, A., Tang, G., Campbell, A. S., Mercier, P. P., & Wang, J.
- Venue
- Advanced Science
- Publisher
- Wiley
- Published
- 2018-08-02
- Volume
- 5
- Issue
- 10
- Pages
- 1800880-1800880
- ISSN
- 2198-3844 (ISSN-L)
- OpenAlex
- W2886783312
- Cited by
- 526
- References
- 41
- FWCI
- 18.12
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.