CoChat

Over 10 000 Peptide Identifications from the HeLa Proteome by Using Single‐Shot Capillary Zone Electrophoresis Combined with Tandem Mass Spectrometry

Open access
Sun, Liangliang, Hebert, Alexander S., Yan, Xiaojing, Zhao, Yimeng, Westphall, Michael S., Rush, Matthew J. P., Zhu, Guijie, Champion, Matthew M., Coon, Joshua J., Dovichi, Norman J. · 2014 · Angewandte Chemie International Edition
Cited by 92

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Capillary zone electrophoresis (CZE)–tandem mass spectrometry (MS/MS) has recently attracted attention as a tool for shotgun proteomics. However, its performance for this analysis has so far fallen far below that of reversed‐phase liquid chromatography (RPLC)–MS/MS. The use of a CZE method with a wide separation window (up to 90 min) and high peak capacity (ca. 300) is reported. This method was coupled to an Orbitrap Fusion mass spectrometer through an electrokinetically pumped sheath‐flow interface for the analysis of complex proteome digests. Single‐shot CZE–MS/MS lead to the identification of over 10 000 peptides and 2100 proteins from a HeLa cell proteome digest in approximately 100 min. This performance is nearly an order of magnitude better than earlier CZE studies and is within a factor of two to four of the state‐of‐the‐art nano ultrahigh‐pressure LC system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/anie.201409075

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

Metadata

Authors
Sun, L., Hebert, A. S., Yan, X., Zhao, Y., Westphall, M. S., Rush, M. J. P., Zhu, G., Champion, M. M., Coon, J. J., & Dovichi, N. J.
Venue
Angewandte Chemie International Edition
Publisher
Wiley
Published
2014-10-24
Volume
53
Issue
50
Pages
13931-13933
ISSN
  • 1433-7851 (ISSN-L)
  • 1521-3773
OpenAlex
W2012157561
Cited by
92
References
11
FWCI
7.07
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.