The DOI matches its Crossref record; 91 of the 91 references it cites were found in a registry or an index.
Activatable Molecular Probes for Second Near‐Infrared Fluorescence, Chemiluminescence, and Photoacoustic Imaging
Abstract
Optical imaging plays a crucial role in biomedicine. However, due to strong light scattering and autofluorescence in biological tissue between 650–900 nm, conventional optical imaging often has a poor signal‐to‐background ratio and shallow penetration depth, which limits its ability in deep‐tissue in vivo imaging. Second near‐infrared fluorescence, chemiluminescence, and photoacoustic imaging modalities mitigate these issues by their respective advantages of minimized light scattering, eliminated external excitation, and ultrasound detection. To enable disease detection, activatable molecular probes (AMPs) with the ability to change their second near‐infrared fluorescence, chemiluminescence, or photoacoustic signals in response to a biomarker have been developed. This Minireview summarizes the molecular design strategies, sensing mechanisms, and imaging applications of AMPs. The potential challenges and perspectives of AMPs in deep‐tissue imaging are also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hong, Y., Lam, J. W. Y., & Tang, B. Z. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15113d · Cited by 6,363
Quantum dot bioconjugates for imaging, labelling and sensing
Medintz, I. L., Uyeda, H. T., Goldman, E. R., & Mattoussi, H. (2005) · Nature Materials · doi:10.1038/nmat1390 · Cited by 6,229
ROS as signalling molecules: Mechanisms that generate specificity in ROS homeostasis
D'Autréaux, B., & Toledano, M. B. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2256 · Cited by 3,642
Near-infrared fluorophores for biomedical imaging
Hong, G., Antaris, A. L., & Dai, H. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0010 · Cited by 2,985
Luminescent Chemodosimeters for Bioimaging
Yang, Y., Zhao, Q., Feng, W., & Li, F. (2013) · Chemical Reviews · doi:10.1021/cr2004103 · Cited by 2,236
Reaction-based small-molecule fluorescent probes for chemoselective bioimaging
Chan, J., Dodani, S. C., & Chang, C. J. (2012) · Nature Chemistry · doi:10.1038/nchem.1500 · Cited by 1,883
Chemistry and biology of reactive oxygen species in signaling or stress responses
Dickinson, B. C., & Chang, C. J. (2011) · Nature Chemical Biology · doi:10.1038/nchembio.607 · Cited by 1,821
Beyond oxidative stress: an immunologist's guide to reactive oxygen species
Nathan, C., & Cunningham-Bussel, A. (2013) · Nature Reviews Immunology · doi:10.1038/nri3423 · Cited by 1,619
Carbon Nanomaterials for Biological Imaging and Nanomedicinal Therapy
Hong, G., Diao, S., Antaris, A. L., & Dai, H. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00008 · Cited by 1,394
Fluoro- and Chromogenic Chemodosimeters for Heavy Metal Ion Detection in Solution and Biospecimens
Quang, D. T., & Kim, J. S. (2010) · Chemical Reviews · doi:10.1021/cr100154p · Cited by 1,355
Contrast agents for molecular photoacoustic imaging
Weber, J., Beard, P. C., & Bohndiek, S. E. (2016) · Nature Methods · doi:10.1038/nmeth.3929 · Cited by 1,270
Li, J., & Pu, K. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00001h · Cited by 1,168
Self-citationMolecular afterglow imaging with bright, biodegradable polymer nanoparticles
Miao, Q., Xie, C., Zhen, X., Lyu, Y., Duan, H., Liu, X., Jokerst, J. V., & Pu, K. (2017) · Nature Biotechnology · doi:10.1038/nbt.3987 · Cited by 975
Self-citationNear‐Infrared‐II Molecular Dyes for Cancer Imaging and Surgery
Zhu, S., Tian, R., Antaris, A. L., Chen, X., & Dai, H. (2019) · Advanced Materials · doi:10.1002/adma.201900321 · Cited by 972
Welsher, K., Sherlock, S. P., & Dai, H. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1014501108 · Cited by 958
Molecular imaging in drug discovery and development
Rudin, M., & Weissleder, R. (2003) · Nature Reviews Drug Discovery · doi:10.1038/nrd1007 · Cited by 815
Zhang, Y., Hong, G., Zhang, Y., Chen, G., Li, F., Dai, H., & Wang, Q. (2012) · ACS Nano · doi:10.1021/nn301218z · Cited by 765
Molecular optical imaging probes for early diagnosis of drug-induced acute kidney injury
Huang, J., Li, J., Lyu, Y., Miao, Q., & Pu, K. (2019) · Nature Materials · doi:10.1038/s41563-019-0378-4 · Cited by 721
Self-citationWu, L., Sedgwick, A. C., Sun, X., Bull, S. D., He, X.-P., & James, T. D. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.9b00302 · Cited by 665
Li, B., Lu, L., Zhao, M., Lei, Z., & Zhang, F. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201801226 · Cited by 658
Shuhendler, A. J., Pu, K., Cui, L., Uetrecht, J. P., & Rao, J. (2014) · Nature Biotechnology · doi:10.1038/nbt.2838 · Cited by 623
Self-citationMiao, Q., & Pu, K. (2018) · Advanced Materials · doi:10.1002/adma.201801778 · Cited by 537
Self-citationAnti-quenching NIR-II molecular fluorophores for in vivo high-contrast imaging and pH sensing
Wang, S., Fan, Y., Li, D., Sun, C., Lei, Z., Lu, L., Wang, T., & Zhang, F. (2019) · Nature Communications · doi:10.1038/s41467-019-09043-x · Cited by 510
Recent Advances in Cell Membrane–Camouflaged Nanoparticles for Cancer Phototherapy
Zhen, X., Cheng, P., & Pu, K. (2019) · Small · doi:10.1002/smll.201804105 · Cited by 483
Self-citationMultimodal Biophotonics of Semiconducting Polymer Nanoparticles
Jiang, Y., & Pu, K. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.8b00242 · Cited by 478
Self-citationLi, J., Rao, J., & Pu, K. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2017.11.025 · Cited by 469
Self-citationA bright organic NIR-II nanofluorophore for three-dimensional imaging into biological tissues
Wan, H., Yue, J., Zhu, S., Uno, T., Zhang, X., Yang, Q., Yu, K., Hong, G., Wang, J., Li, L., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-03505-4 · Cited by 450
Zhen, X., Zhang, J., Huang, J., Xie, C., Miao, Q., & Pu, K. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201803321 · Cited by 352
Self-citationOxidative stress and autophagy: Crucial modulators of kidney injury
Sureshbabu, A., Ryter, S. W., & Choi, M. E. (2015) · Redox Biology · doi:10.1016/j.redox.2015.01.001 · Cited by 350
Zhou, K., Liu, H., Zhang, S., Huang, X., Wang, Y., Huang, G., Sumer, B. D., & Gao, J. (2012) · Journal of the American Chemical Society · doi:10.1021/ja300176w · Cited by 344
Zhen, X., Zhang, C., Xie, C., Miao, Q., Lim, K. L., & Pu, K. (2016) · ACS Nano · doi:10.1021/acsnano.6b02908 · Cited by 340
Self-citationKundu, K., Knight, S. F., Willett, N., Lee, S., Taylor, W. R., & Murthy, N. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200804851 · Cited by 339
Green, O., Eilon, T., Hananya, N., Gutkin, S., Bauer, C. R., & Shabat, D. (2017) · ACS Central Science · doi:10.1021/acscentsci.7b00058 · Cited by 336
A generic approach towards afterglow luminescent nanoparticles for ultrasensitive in vivo imaging
Jiang, Y., Huang, J., Zhen, X., Zeng, Z., Li, J., Xie, C., Miao, Q., Chen, J., Chen, P., & Pu, K. (2019) · Nature Communications · doi:10.1038/s41467-019-10119-x · Cited by 311
Self-citationHypoxia and Hypoxia Inducible Factors: Diverse Roles in Liver Diseases
Nath, B., & Szabo, G. (2012) · Hepatology · doi:10.1002/hep.25497 · Cited by 291
A Gold/Silver Hybrid Nanoparticle for Treatment and Photoacoustic Imaging of Bacterial Infection
Kim, T., Zhang, Q., Li, J., Zhang, L., & Jokerst, J. V. (2018) · ACS Nano · doi:10.1021/acsnano.8b01362 · Cited by 284
Advanced Photoacoustic Imaging Applications of Near‐Infrared Absorbing Organic Nanoparticles
Jiang, Y., & Pu, K. (2017) · Small · doi:10.1002/smll.201700710 · Cited by 277
Self-citationNear-Infrared Dioxetane Luminophores with Direct Chemiluminescence Emission Mode
Green, O., Gnaim, S., Blau, R., Eldar-Boock, A., Satchi-Fainaro, R., & Shabat, D. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.7b08446 · Cited by 277
Huang, J., Xie, C., Zhang, X., Jiang, Y., Li, J., Fan, Q., & Pu, K. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201909560 · Cited by 258
Self-citationLyu, Y., & Pu, K. (2017) · Advanced Science · doi:10.1002/advs.201600481 · Cited by 248
Self-citationSecond Near‐Infrared Absorbing Agents for Photoacoustic Imaging and Photothermal Therapy
Lyu, Y., Li, J., & Pu, K. (2019) · Small Methods · doi:10.1002/smtd.201900553 · Cited by 241
Self-citationUnimolecular Chemo-fluoro-luminescent Reporter for Crosstalk-Free Duplex Imaging of Hepatotoxicity
Cheng, P., Miao, Q., Li, J., Huang, J., Xie, C., & Pu, K. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b02580 · Cited by 234
Self-citationMeng, X., Zhang, J., Sun, Z., Zhou, L., Deng, G., Li, S., Li, W., Gong, P., & Cai, L. (2018) · Theranostics · doi:10.7150/thno.26607 · Cited by 230
A bioreducible N-oxide-based probe for photoacoustic imaging of hypoxia
Knox, H. J., Hedhli, J., Kim, T. W., Khalili, K., Dobrucki, L. W., & Chan, J. (2017) · Nature Communications · doi:10.1038/s41467-017-01951-0 · Cited by 221
An Activatable NIR‐II Nanoprobe for In Vivo Early Real‐Time Diagnosis of Traumatic Brain Injury
Li, C., Li, W., Liu, H., Zhang, Y., Chen, G., Li, Z., & Wang, Q. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.201911803 · Cited by 213
Bruemmer, K. J., Green, O., Su, T. A., Shabat, D., & Chang, C. J. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201802143 · Cited by 199
Schaap, A. P., Handley, R. S., & Giri, B. P. (1987) · Tetrahedron Letters · doi:10.1016/s0040-4039(00)95878-7 · Cited by 194
Smart fluorescent probes for imaging macrophage activity
Fernández, A., & Vendrell, M. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00567a · Cited by 194
Zhang, J., Zhen, X., Zeng, J., & Pu, K. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b01879 · Cited by 192
Self-citationLi, D., Wang, S., Lei, Z., Sun, C., El-Toni, A. M., Alhoshan, M. S., Fan, Y., & Zhang, F. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b00317 · Cited by 188
Novel aza-BODIPY based small molecular NIR-II fluorophores for in vivo imaging
Bai, L., Sun, P., Liu, Y., Zhang, H., Hu, W., Zhang, W., Liu, Z., Fan, Q., Li, L., & Huang, W. (2019) · Chemical Communications · doi:10.1039/c9cc03378e · Cited by 187
Recent Progress in Small-Molecule Near-IR Probes for Bioimaging
Li, J.-B., Liu, H.-W., Fu, T., Wang, R., Zhang, X.-B., & Tan, W. (2019) · Trends in Chemistry · doi:10.1016/j.trechm.2019.03.002 · Cited by 185
Emerging Designs of Activatable Photoacoustic Probes for Molecular Imaging
Miao, Q., & Pu, K. (2016) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.6b00641 · Cited by 173
Self-citationZhao, M., Wang, R., Li, B., Fan, Y., Wu, Y., Zhu, X., & Zhang, F. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201812878 · Cited by 171
Nanotransducers for Near‐Infrared Photoregulation in Biomedicine
Li, J., Duan, H., & Pu, K. (2019) · Advanced Materials · doi:10.1002/adma.201901607 · Cited by 171
Self-citationChemiluminescent probes for imaging H2S in living animals
Cao, J., Lopez, R., Thacker, J. M., Moon, J. Y., Jiang, C., Morris, S. N. S., Bauer, J. H., Tao, P., Mason, R. P., & Lippert, A. R. (2015) · Chemical Science · doi:10.1039/c4sc03516j · Cited by 167
Roth, M. E., Bauer, C. R., & Shabat, D. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201709347 · Cited by 167
Jiang, Y., & Pu, K. (2018) · Advanced Biosystems · doi:10.1002/adbi.201700262 · Cited by 167
Self-citationRedox Regulation of γ-Glutamyl Transpeptidase
Zhang, H., & Forman, H. J. (2009) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/rcmb.2009-0169tr · Cited by 166
Wang, R., Chen, J., Gao, J., Chen, J.-A., Xu, G., Zhu, T., Gu, X., Guo, Z., Zhu, W.-H., & Zhao, C. (2019) · Chemical Science · doi:10.1039/c9sc02093d · Cited by 166
Optical imaging probes for biomolecules: an introductory perspective
Thomas, J. A. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00070j · Cited by 159
Huang, J., Lyu, Y., Li, J., Cheng, P., Jiang, Y., & Pu, K. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201910137 · Cited by 157
Self-citationActivatable imaging probes with amplified fluorescent signals
Lee, S., Park, K., Kim, K., Choi, K., & Kwon, I. C. (2008) · Chemical Communications · doi:10.1039/b806854m · Cited by 152
Gnaim, S., Green, O., & Shabat, D. (2018) · Chemical Communications · doi:10.1039/c8cc00428e · Cited by 143
Recent Advances of Molecular Optical Probes in Imaging of β-Galactosidase
Zhang, J., Cheng, P., & Pu, K. (2019) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.9b00391 · Cited by 140
Self-citationLi, B., Lu, L., Zhao, M., Lei, Z., & Zhang, F. (2018) · Angewandte Chemie · doi:10.1002/ange.201801226 · Cited by 136
Lighting Up NIR-II Fluorescence in Vivo: An Activable Probe for Noninvasive Hydroxyl Radical Imaging
Feng, W., Zhang, Y., Li, Z., Zhai, S., Lv, W., & Liu, Z. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04002 · Cited by 133
Lv, Y., Cheng, D., Su, D. S. D., Chen, M., Yin, B., Yuan, L., & Zhang, X. (2018) · Chemical Science · doi:10.1039/c8sc03308k · Cited by 131
Yu, F., Shi, W. S., Hu, Y., Li, X., & Ma, H. (2018) · Chemical Communications · doi:10.1039/c8cc02209g · Cited by 130
In Vivo Chemiluminescent Imaging Agents for Nitroreductase and Tissue Oxygenation
Cao, J. X., Campbell, J., Liu, L., Mason, R. P., & Lippert, A. R. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b01096 · Cited by 128
A Renal‐Clearable Macromolecular Reporter for Near‐Infrared Fluorescence Imaging of Bladder Cancer
Huang, J., Jiang, Y., Li, J., He, S., Huang, J., & Pu, K. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201911859 · Cited by 126
Self-citationYin, C., Tang, Y., Li, X., Yáng, Z., Li, J., Li, X., Huang, W., & Fan, Q. (2018) · Small · doi:10.1002/smll.201703400 · Cited by 119
NIR‐II Fluorescence Endoscopy for Targeted Imaging of Colorectal Cancer
Suo, Y., Wu, F., Xu, P., Shi, H., Wang, T., Liu, H., & Cheng, Z. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900974 · Cited by 110
Gnaim, S., & Shabat, D. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.9b00338 · Cited by 105
Activatable Molecular Probes for Cancer Imaging
Lee, S., Xie, J., & Chen, X. S. (2010) · Current Topics in Medicinal Chemistry · doi:10.2174/156802610791384270 · Cited by 99
Xu, Z. J., Zhang, J., Huang, J., Xie, C., Miao, Q., & Pu, K. (2018) · Angewandte Chemie · doi:10.1002/ange.201803321 · Cited by 84
Self-citationJeevarathinam, A. S., Lemaster, J. E., Chen, F., Zhao, E., & Jokerst, J. V. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201914120 · Cited by 81
Huang, L., Zhu, S., Cui, R., & Zhang, M. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04156 · Cited by 77
Nanobody‐Conjugated Nanotubes for Targeted Near‐Infrared In Vivo Imaging and Sensing
Mann, F. A., Lv, Z., Großhans, J., Opazo, F., & Kruss, S. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201904167 · Cited by 74
Bruemmer, K. J., Green, O., Su, T. A., Shabat, D., & Chang, C. J. (2018) · Angewandte Chemie · doi:10.1002/ange.201802143 · Cited by 70
Roth, M. E., Bauer, C. R., & Shabat, D. (2017) · Angewandte Chemie · doi:10.1002/ange.201709347 · Cited by 65
Bi, A., Yang, S., Liu, M., Wang, X., Liao, W., & Zeng, W. (2017) · RSC Advances · doi:10.1039/c7ra05651f · Cited by 49
Zhao, M., Wang, R., Li, B., Fan, Y., Wu, Y., Zhu, X., & Zhang, F. (2018) · Angewandte Chemie · doi:10.1002/ange.201812878 · Cited by 48
Hrbáč, J., & Kohen, R. (2000) · Drug Development Research · Cited by 47
Development of optical nanoprobes for molecular imaging of reactive oxygen and nitrogen species
Xu, Z. J., & Pu, K. (2018) · Nano Research · doi:10.1007/s12274-018-2135-4 · Cited by 45
Self-citationHuang, J., Lyu, Y., Li, J., Cheng, P., Jiang, Y., & Pu, K. (2019) · Angewandte Chemie · doi:10.1002/ange.201910137 · Cited by 36
Self-citationHuang, J., Xie, C., Zhang, X., Jiang, Y., Li, J., Fan, Q., & Pu, K. (2019) · Angewandte Chemie · doi:10.1002/ange.201909560 · Cited by 36
Self-citationAn Activatable NIR‐II Nanoprobe for In Vivo Early Real‐Time Diagnosis of Traumatic Brain Injury
Li, C., Li, W., Liu, H., Zhang, Y., Chen, G., Li, Z., & Wang, Q. (2019) · Angewandte Chemie · doi:10.1002/ange.201911803 · Cited by 29
A Renal‐Clearable Macromolecular Reporter for Near‐Infrared Fluorescence Imaging of Bladder Cancer
Huang, J., Jiang, Y., Li, J., He, S., Huang, J., & Pu, K. (2019) · Angewandte Chemie · doi:10.1002/ange.201911859 · Cited by 21
Self-citationXie, C., Cheng, P., & Pu, K. (2018) · Chemistry - A European Journal · doi:10.1002/chem.201705716 · Cited by 20
Self-citationMann, F. A., Lv, Z., Großhans, J., Opazo, F., & Kruss, S. (2019) · Angewandte Chemie · doi:10.1002/ange.201904167 · Cited by 11
Cited by
Advanced Fluorescence Imaging Technology in the Near-Infrared-II Window for Biomedical Applications
Li, C., Chen, G., Zhang, Y., Wu, F., & Wang, Q. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c07022 · Cited by 1,037
Second near-infrared photothermal materials for combinational nanotheranostics
Xu, C., & Pu, K. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00664e · Cited by 941
Self-citationDang, Q., Jiang, Y., Wang, J., Wang, J., Zhang, Q., Zhang, M., Luo, S., Xie, Y., Pu, K., Li, Q., et al. (2020) · Advanced Materials · doi:10.1002/adma.202006752 · Cited by 472
Self-citationShi, Z., Han, X., Hu, W., Bai, H., Peng, B., Ji, L., Fan, Q., Li, L., & Huang, W. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00234h · Cited by 469
NIR‐II AIEgens: A Win–Win Integration towards Bioapplications
Xu, W., Wang, D., & Tang, B. Z. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202005899 · Cited by 457
Metadata
- Authors
- Huang, J., & Pu, K.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2020-04
- Volume
- 59
- Issue
- 29
- Pages
- 11717-11731
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W3010187002
- Cited by
- 541
- References
- 91
- FWCI
- 31.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.