The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
NIR‐II Chemiluminescence Molecular Sensor for In Vivo High‐Contrast Inflammation Imaging
Abstract
Chemiluminescence (CL) sensing without external excitation by light and autofluorescence interference has been applied to high‐contrast in vitro immunoassays and in vivo inflammation and tumor microenvironment detection. However, conventional CL sensing usually operates in the range of 400–850 nm, which limits the performance of in vivo imaging due to serious light scattering effects and signal attenuation in tissue. To address this challenge, a new type of CL sensor is presented that functions in the second near‐infrared window (NIR‐II CLS) with a deep penetration depth (≈8 mm). Successive CL resonance energy transfer (CRET) and Förster resonance energy transfer (FRET) from the activated CL substrate to two rationally designed donor‐acceptor‐donor fluorophores BTD540 and BBTD700 occurs. NIR‐II CLS can be selectively activated by hydrogen peroxide over other reactive oxygen species (ROSs). Moreover, NIR‐II CLS is capable of detecting local inflammation in mice with a 4.5‐fold higher signal‐to‐noise ratio (SNR) than that under the NIR‐II fluorescence modality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical properties of biological tissues: A review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/r37 · Cited by 4,008
Second window for in vivo imaging
Smith, A. M., Mancini, M. C., & Nie, S. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.326 · Cited by 2,848
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
He, S., Song, J., Qu, J., & Cheng, Z. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00234g · Cited by 1,021
J -Aggregates of Cyanine Dye for NIR-II in Vivo Dynamic Vascular Imaging beyond 1500 nm
Sun, C., Li, B., Zhao, M., Wang, S., Lei, Z., Lu, L., Zhang, H., Feng, L., Dou, C., Yin, D., et al. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b10043 · Cited by 582
Self-citationDonor Engineering for NIR-II Molecular Fluorophores with Enhanced Fluorescent Performance
Yang, Q., Hu, Z., Zhu, S., Ma, R., Ma, H., Ma, Z., Wan, H., Zhu, T., Jiang, Z., Liu, W., et al. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.7b10334 · Cited by 554
Research works printed but not linked: 67
- 10.1126/science.1146598 · DOI · Paper page
- 10.1126/science.aaq1392 · DOI · Paper page
- 10.1126/science.aau8302 · DOI · Paper page
- 10.1038/s41551-016-0010 · DOI · Paper page
- 10.1038/s41563-019-0378-4 · DOI · Paper page
- 10.1038/s41467-019-09043-x · DOI · Paper page
- 10.1039/C8SC00633D · DOI
- 10.1016/j.biomaterials.2018.03.041 · DOI
- 10.1021/acs.analchem.8b00603 · DOI
- 10.1002/adma.201802394 · DOI · Paper page
- 10.1002/cbic.201800466 · DOI
- 10.1073/pnas.1803210115 · DOI
- 10.1002/adhm.201800973 · DOI
- 10.1002/adhm.201800589 · DOI
- 10.1039/C7SC04774F · DOI · Paper page
- 10.1038/nbt994 · DOI · Paper page
- 10.1038/nchembio.2096 · DOI
- 10.1038/s41467-018-05947-2 · DOI · Paper page
- 10.1021/jacs.8b05514 · DOI · Paper page
- 10.1039/C9SC05600A · DOI
- 10.1021/jacs.9b12873 · DOI · Paper page
- 10.1002/anie.201914768 · DOI · Paper page
- 2020, Angew. Chem., 132, 1183
- 10.1002/adma.201603583 · DOI
- 10.1021/cr900343z · DOI · Paper page
- 10.1007/s12274-015-0808-9 · DOI · Paper page
- 10.1016/j.nano.2017.02.013 · DOI
- 10.1039/b923679c · DOI · Paper page
- 10.1016/S0040-4039(01)90712-9 · DOI
- 10.1201/9781482270693 · DOI · Paper page
- 10.1088/0957-4484/18/29/295707 · doi:10.1088/0957-4484/18/29/295707
- 10.1002/anie.200601196 · DOI · Paper page
- 10.1002/ange.200601196 · doi:10.1002/ange.200601196
- 10.1016/j.aca.2008.01.018 · doi:10.1016/j.aca.2008.01.018
- 10.1021/ar50142a003 · DOI · Paper page
- 10.1111/j.1751-1097.1995.tb08706.x · DOI
- 10.1021/ja00460a050 · DOI
- 10.1073/pnas.75.1.30 · DOI
- 10.1021/ja00482a030 · DOI
- 10.1038/ncomms3199 · DOI · Paper page
- 10.1038/nmat1983 · DOI · Paper page
- 10.1021/ac5041605 · DOI
- 10.1002/adfm.201000780 · DOI
- 10.1016/j.biomaterials.2016.01.038 · DOI
- 10.1021/nn3014905 · DOI · Paper page
- 10.1038/nbt.2838 · DOI · Paper page
- 10.1021/acsnano.6b02908 · DOI · Paper page
- 10.1007/s13233-014-2148-0 · DOI
- 10.1002/adfm.201200773 · doi:10.1002/adfm.201200773
- 10.1021/acsnano.5b03377 · DOI
- 10.1016/j.chempr.2017.10.002 · DOI · Paper page
- 10.1021/jacs.9b02580 · DOI · Paper page
- 10.1002/anie.201910137 · DOI
- 10.1002/ange.201910137 · DOI
- 10.1002/anie.201706969 · DOI · Paper page
- 10.1002/ange.201706969 · doi:10.1002/ange.201706969
- 10.1039/C8CC00428E · DOI
- 10.1039/C8SC05174G · DOI
- 10.1002/adma.201906314 · DOI
- 10.1016/j.snb.2017.02.019 · DOI
- 10.1002/bio.2555 · doi:10.1002/bio.2555
- 10.1016/j.talanta.2017.05.007 · DOI
- 10.1039/an9830801067 · DOI · Paper page
- 10.1038/srep34954 · doi:10.1038/srep34954
- 10.1002/jbio.201300141 · DOI
- 10.1038/s41467-019-10119-x · DOI · Paper page
- 10.1038/nbt.3987 · DOI · Paper page
Cited by
Near-infrared luminescence high-contrast in vivo biomedical imaging
Chen, Y., Wang, S., & Zhang, F. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-022-00002-8 · Cited by 566
Self-citationFluorescent Probes for Disease Diagnosis
Wang, X., Ding, Q., Groleau, R. R., Wu, L., Mao, Y., Che, F., Kotova, O., Scanlan, E. M., Lewis, S. E., Li, P., et al. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00776 · Cited by 543
Molecular Probes for Autofluorescence-Free Optical Imaging
Jiang, Y., & Pu, K. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00506 · Cited by 426
A materials-science perspective on tackling COVID-19
Tang, Z., Kong, N., Zhang, X., Liu, Y., Hu, P., Mou, S., Liljeström, P., Shi, J., Tan, W., Kim, J. S., et al. (2020) · Nature Reviews Materials · doi:10.1038/s41578-020-00247-y · Cited by 303
NIR-II bioimaging of small organic molecule
Su, Y., Yu, B., Wang, S., Cong, H., & Shen, Y. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2021.120717 · Cited by 251
Self-citation
Metadata
- Authors
- Yang, Y., Wang, S., Lu, L., Zhang, Q., Yu, P., Fan, Y., & Zhang, F.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2020-08-12
- Volume
- 59
- Issue
- 42
- Pages
- 18380-18385
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W3037692580
- Cited by
- 186
- References
- 6
- FWCI
- 9.30
- Type
- journal article
- Language
- en
- Open access
- closed
- Funders
- National Natural Science Foundation of China (21725502)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: NIR‐II Chemiluminescence Molecular Sensor for In Vivo High‐Contrast Inflammation Imaging. https://app.cochat.ai/papers/10.1002/anie.202007649
- The paper
- Yang, Y., Wang, S., Lu, L., Zhang, Q., Yu, P., Fan, Y., & Zhang, F. (2020). NIR‐II Chemiluminescence Molecular Sensor for In Vivo High‐Contrast Inflammation Imaging. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.202007649
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.