A neuroradiologist’s guide to arterial spin labeling MRI in clinical practice
Open accessThe DOI matches its Crossref record; 164 of the 164 references it cites were found in a registry or an index.
Abstract
Arterial spin labeling (ASL) is a non-invasive MRI technique to measure cerebral blood flow (CBF). This review provides a practical guide and overview of the clinical applications of ASL of the brain, as well its potential pitfalls. The technical and physiological background is also addressed. At present, main areas of interest are cerebrovascular disease, dementia and neuro-oncology. In cerebrovascular disease, ASL is of particular interest owing to its quantitative nature and its capability to determine cerebral arterial territories. In acute stroke, the source of the collateral blood supply in the penumbra may be visualised. In chronic cerebrovascular disease, the extent and severity of compromised cerebral perfusion can be visualised, which may be used to guide therapeutic or preventative intervention. ASL has potential for the detection and follow-up of arteriovenous malformations. In the workup of dementia patients, ASL is proposed as a diagnostic alternative to PET. It can easily be added to the routinely performed structural MRI examination. In patients with established Alzheimer's disease and frontotemporal dementia, hypoperfusion patterns are seen that are similar to hypometabolism patterns seen with PET. Studies on ASL in brain tumour imaging indicate a high correlation between areas of increased CBF as measured with ASL and increased cerebral blood volume as measured with dynamic susceptibility contrast-enhanced perfusion imaging. Major advantages of ASL for brain tumour imaging are the fact that CBF measurements are not influenced by breakdown of the blood-brain barrier, as well as its quantitative nature, facilitating multicentre and longitudinal studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Alsop, D. C., Detre, J. A., Golay, X., Günther, M., Hendrikse, J., Hernandez‐Garcia, L., Lu, H., MacIntosh, B. J., Parkes, L. M., Smits, M., et al. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25197 · Cited by 2,206
Self-citationDetre, J. A., Leigh, J. S., Williams, D. S., & Koretsky, A. P. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230106 · Cited by 1,571
Magnetic resonance imaging of perfusion using spin inversion of arterial water.
Williams, D. S., Detre, J. A., Leigh, J. S., & Koretsky, A. P. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.212 · Cited by 1,546
The North American Symptomatic Carotid Endarterectomy Trial: Surgical Results in 1415 Patients
Ferguson, G. G., Eliasziw, M., Barr, H. W. K., Clagett, G. P., Barnes, R. W., Wallace, M. C., Taylor, D. W., Haynes, R. B., Finan, J. W., Hachinski, V. C., et al. (1999) · Stroke · doi:10.1161/01.str.30.9.1751 · Cited by 1,503
A general kinetic model for quantitative perfusion imaging with arterial spin labeling
Buxton, R. B., Frank, L. R., Wong, E. C., Siewert, B., Warach, S., & Edelman, R. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400308 · Cited by 1,263
Rothwell, P. M., Giles, M. F., Chandratheva, A., Marquardt, L., Geraghty, O., Redgrave, J. N., Lovelock, C. E., Binney, L. E., Bull, L. M., Cuthbertson, F. C., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61448-2 · Cited by 1,190
Ollinger, J. M., & Fessler, J. A. (1997) · IEEE Signal Processing Magazine · doi:10.1109/79.560323 · Cited by 1,167
(1991) · Stroke · doi:10.1161/01.str.22.6.711 · Cited by 1,133
Nephrogenic Systemic Fibrosis: Risk Factors and Incidence Estimation
Sadowski, E. A., Bennett, L. K., Chan, M. R., Wentland, A. L., Garrett, A. L., Garrett, R. W., & Djamali, A. (2007) · Radiology · doi:10.1148/radiol.2431062144 · Cited by 1,018
Kim, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340303 · Cited by 1,001
Dai, W., Garcia, D., de Bazelaire, C., & Alsop, D. C. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21790 · Cited by 985
Alsop, D. C., & Detre, J. A. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199611000-00019 · Cited by 754
Quantitative interpretation of magnetization transfer
Henkelman, R. M., Huang, X., Xiang, Q., Stanisz, G. J., Swanson, S. D., & Bronskill, M. J. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290607 · Cited by 734
What is the Correct Value for the Brain-Blood Partition Coefficient for Water?
Herscovitch, P., & Raichle, M. E. (1985) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1985.9 · Cited by 705
Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla
Lu, H., Clingman, C., Golay, X., & van Zijl, P. C. M. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20178 · Cited by 685
Self-citationComparative Overview of Brain Perfusion Imaging Techniques
Wintermark, M., Sesay, M., Barbier, E., Borbély, K., Dillon, W. P., Eastwood, J. D., Glenn, T. C., Grandin, C. B., Pedraza, S., Soustiel, J.-F., et al. (2005) · Stroke · doi:10.1161/01.str.0000177884.72657.8b · Cited by 592
Johnson, N. A., Jahng, G.-H., Weiner, M. W., Miller, B. L., Chui, H. C., Jagust, W. J., Gorno-Tempini, M. L., & Schuff, N. (2005) · Radiology · doi:10.1148/radiol.2343040197 · Cited by 587
Wong, E. C., Buxton, R. B., & Frank, L. R. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199706/08)10:4/5<237::aid-nbm475>3.0.co;2-x · Cited by 584
Perfusion functional MRI reveals cerebral blood flow pattern under psychological stress
Wang, J., Rao, H., Wetmore, G. S., Furlan, P. M., Korczykowski, M., Dinges, D. F., & Detre, J. A. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503082102 · Cited by 513 · cited 1×
“These include for instance mood [166], blood gases [167], nutrition [168], stress [169], and medication use.”
BackgroundChalela, J. A., Alsop, D. C., Gonzalez-Atavales, J. B., Maldjian, J. A., Kasner, S. E., & Detre, J. A. (2000) · Stroke · doi:10.1161/01.str.31.3.680 · Cited by 481
Functional magnetic resonance imaging based on changes in vascular space occupancy
Lu, H., Golay, X., Pekar, J. J., & van Zijl, P. C. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10519 · Cited by 463
Self-citationParkes, L. M., Rashid, W., Chard, D. T., & Tofts, P. S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20023 · Cited by 449
Elevation in cerebral blood flow velocity with aerobic fitness throughout healthy human ageing
Ainslie, P. N., Cotter, J. D., George, K. P., Lucas, S., Murrell, C., Shave, R., Thomas, K. N., Williams, M. J. A., & Atkinson, G. (2008) · The Journal of Physiology · doi:10.1113/jphysiol.2008.158279 · Cited by 444 · cited 1×
“These include genetics, cognitive capacity [162], personality traits [163], physical exercise [164], and age [165].”
BackgroundAssessment of cerebral blood flow in Alzheimer's disease by spin-labeled magnetic resonance imaging
Alsop, D. C., Detre, J. A., & Grossman, M. (2000) · Annals of Neurology · doi:10.1002/1531-8249(200001)47:1<93::aid-ana15>3.0.co;2-8 · Cited by 409
Dai, W., Lopez, O. L., Carmichael, O. T., Becker, J. T., Kuller, L. H., & Gach, H. M. (2009) · Radiology · doi:10.1148/radiol.2503080751 · Cited by 398
Page, K. A., Chan, O., Arora, J., Belfort-DeAguiar, R., Dzuira, J., Roehmholdt, B., Cline, G. W., Naik, S., Sinha, R., Constable, R. T., et al. (2013) · JAMA · doi:10.1001/jama.2012.116975 · Cited by 379 · cited 1×
“These include for instance mood [166], blood gases [167], nutrition [168], stress [169], and medication use.”
BackgroundComparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla
Wang, J., Alsop, D. C., Li, L., Listerud, J., Gonzalez‐At, J. B., Schnall, M. D., & Detre, J. A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10211 · Cited by 369
Perfusion MRI: The Five Most Frequently Asked Technical Questions
Essig, M., Shiroishi, M. S., Nguyen, T. B., Saake, M., Provenzale, J. M., Enterline, D., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9543 · Cited by 366
Warmuth, C., Günther, M., & Zimmer, C. (2003) · Radiology · doi:10.1148/radiol.2282020409 · Cited by 364
Age-associated reductions in cerebral blood flow are independent from regional atrophy
Chen, J. J., Rosas, H. D., & Salat, D. H. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.12.032 · Cited by 360
Non-invasive measurement of perfusion: a critical review of arterial spin labelling techniques
Petersen, E. T., Zimine, I., Ho, Y.-C. L., & Golay, X. (2006) · The British Journal of Radiology · doi:10.1259/bjr/67705974 · Cited by 352
Self-citationPerfusion MRI: The Five Most Frequently Asked Clinical Questions
Essig, M., Nguyen, T. B., Shiroishi, M. S., Saake, M., Provenzale, J. M., Enterline, D. S., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9544 · Cited by 344
GRASE (Gradient‐and Spin‐Echo) imaging: A novel fast MRI technique
Oshio, K., & Feinberg, D. A. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910200219 · Cited by 340
Simner, J. (2009) · Cited by 338
Routine clinical brain MRI sequences for use at 3.0 Tesla
Lu, H., Nagae‐Poetscher, L. M., Golay, X., Lin, D., Pomper, M., & van Zijl, P. C. M. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20356 · Cited by 327
Self-citationApplications of arterial spin labeled MRI in the brain
Detre, J. A., Rao, H., Wang, D. J. J., Chen, Y. F., & Wang, Z. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23581 · Cited by 326
Model‐free arterial spin labeling quantification approach for perfusion MRI
Petersen, E. T., Lim, T., & Golay, X. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20784 · Cited by 305
Self-citationArterial Spin-Labeling in Routine Clinical Practice, Part 1: Technique and Artifacts
Deibler, A. R., Pollock, J. M., Kraft, R. A., Tan, H., Burdette, J. H., & Maldjian, J. A. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1030 · Cited by 298
Hypoperfusion in frontotemporal dementia and Alzheimer disease by arterial spin labeling MRI
Du, A. T., Jahng, G. H., Hayasaka, S., Kramer, J. H., Rosen, H. J., Gorno-Tempini, M. L., Rankin, K. P., Miller, B. L., Weiner, M. W., & Schuff, N. (2006) · Neurology · doi:10.1212/01.wnl.0000238163.71349.78 · Cited by 288
Xu, G., Rowley, H. A., Wu, G., Alsop, D. C., Shankaranarayanan, A., Dowling, M., Christian, B. T., Oakes, T. R., & Johnson, S. C. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1462 · Cited by 280
Arterial transit time imaging with flow encoding arterial spin tagging (FEAST)
Wang, J., Alsop, D. C., Song, H. K., Maldjian, J. A., Tang, K., Salvucci, A. E., & Detre, J. A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10559 · Cited by 275
Diagnostic performance of spectroscopic and perfusion MRI for distinction of brain tumors
Weber, M. A., Zoubaa, S., Schlieter, M., Jüttler, E., Huttner, H. B., Geletneky, K., Ittrich, C., Lichy, M. P., Kroll, A., Debus, J., et al. (2006) · Neurology · doi:10.1212/01.wnl.0000219767.49705.9c · Cited by 268
Efficiency of inversion pulses for background suppressed arterial spin labeling
Garcia, D. M., Duhamel, G., & Alsop, D. C. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20556 · Cited by 260
Binnewijzend, M. A. A., Kuijer, J. P. A., Benedictus, M. R., van der Flier, W. M., Wink, A. M., Wattjes, M. P., van Berckel, B. N. M., Scheltens, P., & Barkhof, F. (2013) · Radiology · doi:10.1148/radiol.12120928 · Cited by 260
Voxel-level comparison of arterial spin-labeled perfusion MRI and FDG-PET in Alzheimer disease
Chen, Y., Wolk, D. A., Reddin, J. S., Korczykowski, M., Martinez, P. M., Musiek, E. S., Newberg, A. B., Julin, P., Arnold, S. E., Greenberg, J. H., et al. (2011) · Neurology · doi:10.1212/wnl.0b013e31823a0ef7 · Cited by 259
ASL Perfusion MRI Predicts Cognitive Decline and Conversion From MCI to Dementia
Chao, L. L., Buckley, S. T., Kornak, J., Schuff, N., Madison, C., Yaffe, K., Miller, B. L., Kramer, J. H., & Weiner, M. W. (2010) · Alzheimer Disease & Associated Disorders · doi:10.1097/wad.0b013e3181b4f736 · Cited by 257
Perfusion Imaging Using Arterial Spin Labeling
Golay, X., Hendrikse, J., & Lim, T. C. C. (2004) · Topics in Magnetic Resonance Imaging · doi:10.1097/00002142-200402000-00003 · Cited by 256
Self-citationWong, E. C., Buxton, R. B., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400303 · Cited by 250
Biagi, L., Abbruzzese, A., Bianchi, M. C., Alsop, D. C., Del Guerra, A., & Tosetti, M. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20839 · Cited by 241
Regression algorithm correcting for partial volume effects in arterial spin labeling MRI
Asllani, I., Borogovac, A., & Brown, T. R. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21670 · Cited by 241
Clinical Neuroimaging Using Arterial Spin-Labeled Perfusion Magnetic Resonance Imaging
Wolf, R. L., & Detre, J. A. (2007) · Neurotherapeutics · doi:10.1016/j.nurt.2007.04.005 · Cited by 239
Pediatric perfusion imaging using pulsed arterial spin labeling
Wang, J., Licht, D. J., Jahng, G., Liu, C., Rubin, J. T., Haselgrove, J., Zimmerman, R. A., & Detre, J. A. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10372 · Cited by 238
Zaharchuk, G., Do, H. M., Marks, M. P., Rosenberg, J., Moseley, M. E., & Steinberg, G. K. (2011) · Stroke · doi:10.1161/strokeaha.111.616466 · Cited by 234
Contrast manipulation and artifact assessment of 2D and 3D RARE sequences
Mulkern, R. V., Wong, S. T. S., Winalski, C., & Jolesz, F. A. (1990) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(90)90132-l · Cited by 231
Wang, D. J. J., Alger, J. R., Qiao, J. X., Gunther, M., Pope, W. B., Saver, J. L., Salamon, N., & Liebeskind, D. S. (2013) · NeuroImage: Clinical · doi:10.1016/j.nicl.2013.06.017 · Cited by 228
Noguchi, T., Yoshiura, T., Hiwatashi, A., Togao, O., Yamashita, K., Nagao, E., Shono, T., Mizoguchi, M., Nagata, S., Sasaki, T., et al. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a0903 · Cited by 226
Wierenga, C. E., Hays, C. C., & Zlatar, Z. Z. (2014) · Journal of Alzheimer's Disease · doi:10.3233/jad-141467 · Cited by 224
Imaging in the surgical treatment of epilepsy
Duncan, J. S. (2010) · Nature Reviews Neurology · doi:10.1038/nrneurol.2010.131 · Cited by 219
Ances, B. M., Liang, C. L., Leontiev, O., Perthen, J. E., Fleisher, A. S., Lansing, A. E., & Buxton, R. B. (2009) · Human Brain Mapping · doi:10.1002/hbm.20574 · Cited by 217
Role of Brain Inflammation in Epileptogenesis
Choi, J., & Koh, S. (2008) · Yonsei Medical Journal · doi:10.3349/ymj.2008.49.1.1 · Cited by 216
Effects of Hypoperfusion in Alzheimer's Disease
Austin, B. P., Nair, V. A., Meier, T. B., Xu, G., Rowley, H. A., Carlsson, C. M., Johnson, S. C., & Prabhakaran, V. (2011) · Journal of Alzheimer's Disease · doi:10.3233/jad-2011-0010 · Cited by 215
The effect of daily caffeine use on cerebral blood flow: How much caffeine can we tolerate?
Addicott, M. A., Yang, L. L., Peiffer, A. M., Burnett, L. R., Burdette, J. H., Chen, M. Y., Hayasaka, S., Kraft, R. A., Maldjian, J. A., & Laurienti, P. J. (2009) · Human Brain Mapping · doi:10.1002/hbm.20732 · Cited by 210 · cited 1×
“cup of coffee or smoking a cigarette just before the perfusion measurement has substantial influence on both global and local quantification [170, 171].”
BackgroundNoninvasive MRI evaluation of cerebral blood flow in cerebrovascular disease
Detre, J. A., Alsop, D. C., Vives, L. R., Maccotta, L., Teener, J. W., & Raps, E. C. (1998) · Neurology · doi:10.1212/wnl.50.3.633 · Cited by 209
Arterial spin labelling reveals an abnormal cerebral perfusion pattern in Parkinson's disease
Melzer, T. R., Watts, R., MacAskill, M. R., Pearson, J. F., Rueger, S., Pitcher, T. L., Livingston, L., Graham, C., Keenan, R., Shankaranarayanan, A., et al. (2011) · Brain · doi:10.1093/brain/awq377 · Cited by 205
Can arterial spin labeling detect white matter perfusion signal?
van Osch, M. J. P., Teeuwisse, W. M., van Walderveen, M. A. A., Hendrikse, J., Kies, D. A., & van Buchem, M. A. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22002 · Cited by 204
Hippocampal hyperperfusion in Alzheimer's disease
Alsop, D. C., Casement, M., de Bazelaire, C., Fong, T., & Press, D. Z. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.06.006 · Cited by 202
Schuff, N., Matsumoto, S., Kmiecik, J., Studholme, C., Du, A., Ezekiel, F., Miller, B. L., Kramer, J. H., Jagust, W. J., Chui, H. C., et al. (2009) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2009.04.1233 · Cited by 200
Arterial Spin-Labeling in Routine Clinical Practice, Part 3: Hyperperfusion Patterns
Deibler, A. R., Pollock, J. M., Kraft, R. A., Tan, H., Burdette, J. H., & Maldjian, J. A. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1034 · Cited by 193
Distinct cerebral perfusion patterns in FTLD and AD
Hu, W. T., Wang, Z., Lee, V. M.-Y., Trojanowski, J. Q., Detre, J. A., & Grossman, M. (2010) · Neurology · doi:10.1212/wnl.0b013e3181f11e35 · Cited by 183
Van Paesschen, W. (2004) · Epilepsia · doi:10.1111/j.0013-9580.2004.04008.x · Cited by 183
Järnum, H., Steffensen, E. G., Knutsson, L., Fründ, E.-T., Simonsen, C. W., Lundbye-Christensen, S., Shankaranarayanan, A., Alsop, D. C., Jensen, F. T., & Larsson, E.-M. (2010) · Neuroradiology · doi:10.1007/s00234-009-0616-6 · Cited by 179
Musiek, E. S., Chen, Y., Korczykowski, M., Saboury, B., Martinez, P. M., Reddin, J. S., Alavi, A., Kimberg, D. Y., Wolk, D. A., Julin, P., et al. (2012) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2011.06.003 · Cited by 178
Pittfalls of MRI measurement of white matter perfusion based on arterial spin labeling
van Gelderen, P., de Zwart, J. A., & Duyn, J. H. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21515 · Cited by 176
Asllani, I., Habeck, C., Scarmeas, N., Borogovac, A., Brown, T. R., & Stern, Y. (2008) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600570 · Cited by 172 · cited 1×
“In addition, hypoperfusion in the lateral parietal cortex bilaterally supports the diagnosis [135, 137, 138].”
BackgroundWang, D. J. J., Alger, J. R., Qiao, J. X., Hao, Q., Hou, S., Fiaz, R., Gunther, M., Pope, W. B., Saver, J. L., Salamon, N., et al. (2012) · Stroke · doi:10.1161/strokeaha.111.631929 · Cited by 170
Flow Territory Mapping of the Cerebral Arteries With Regional Perfusion MRI
Hendrikse, J., van der Grond, J., Lu, H., van Zijl, P. C. M., & Golay, X. (2004) · Stroke · doi:10.1161/01.str.0000120312.26163.ec · Cited by 164
Self-citationComparison of 2D and 3D single-shot ASL perfusion fMRI sequences
Vidorreta, M., Wang, Z., Rodríguez, I., Pastor, M. A., Detre, J. A., & Fernández-Seara, M. A. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.10.087 · Cited by 164
Wolf, R. L., Alsop, D. C., Levy-Reis, I., Meyer, P. T., Maldjian, J. A., Gonzalez-Atavales, J. B., French, J. A., Alavi, A. A., & Detre, J. A. (2001) · PubMed · Cited by 160
Impaired Cerebrovascular Reactivity in Multiple Sclerosis
Marshall, O., Lu, H., Brisset, J., Xu, F., Liu, P., Herbert, J., Grossman, R. I., & Ge, Y. (2014) · JAMA Neurology · doi:10.1001/jamaneurol.2014.1668 · Cited by 157
Wolk (2012) · doi:10.1097/wco.0b013e328354ff0a · Cited by 147
Ictal Pleasant Sensations: Cerebral Localization and Lateralization
Stefan, H., Schulze‐Bonhage, A., Pauli, E., Platsch, G., Quiske, A., Buchfelder, M., & Romstöck, J. (2004) · Epilepsia · doi:10.1111/j.0013-9580.2004.09303.x · Cited by 143
Bokkers, R. P. H., Bremmer, J. P., van Berckel, B. N. M., Lammertsma, A. A., Hendrikse, J., Pluim, J. P. W., Kappelle, L. J., Boellaard, R., & Klijn, C. J. M. (2009) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2009.204 · Cited by 140
Alexopoulos, P., Sorg, C., Förschler, A., Grimmer, T., Σκώκου, Μ., Wohlschläger, A. M., Perneczky, R., Zimmer, C., Kurz, A., & Preibisch, C. (2011) · European Archives of Psychiatry and Clinical Neuroscience · doi:10.1007/s00406-011-0226-2 · Cited by 135
Arterial Spin-Labeling in Routine Clinical Practice, Part 2: Hypoperfusion Patterns
Deibler, A. R., Pollock, J. M., Kraft, R., Tan, H., Burdette, J. H., & Maldjian, J. A. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1033 · Cited by 134
Pinkham, A., Loughead, J., Ruparel, K., Wu, W.-C., Overton, E., Gur, R., & Gur, R. (2011) · Psychiatry Research: Neuroimaging · doi:10.1016/j.pscychresns.2011.06.013 · Cited by 130
Primary Cerebral Blood Flow Deficiency and Alzheimer's Disease: Shadows and Lights
Mazza, M., Marano, G., Traversi, G., Bria, P., & Mazza, S. (2011) · Journal of Alzheimer's Disease · doi:10.3233/jad-2010-090700 · Cited by 129
Detre, J. A., Samuels, O. B., Alsop, D. C., Gonzalez-Atavales, J. B., Kasner, S. E., & Raps, E. C. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199911)10:5<870::aid-jmri36>3.0.co;2-d · Cited by 127
An introduction to ASL labeling techniques
Wong, E. C. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24565 · Cited by 125
Chng, S. M., Petersen, E. T., Zimine, I., Sitoh, Y., Lim, C. C. T., & Golay, X. (2008) · Stroke · doi:10.1161/strokeaha.108.520593 · Cited by 116
Self-citationHandley, R., Zelaya, F. O., Reinders, A. A. T. S., Marques, T. R., Mehta, M. A., O'Gorman, R., Alsop, D. C., Taylor, H., Johnston, A., Williams, S., et al. (2013) · Human Brain Mapping · doi:10.1002/hbm.21436 · Cited by 108
Jain, V., Duda, J., Avants, B., Giannetta, M., Xie, S. X., Roberts, T. P. L., Detre, J. A., Hurt, H., Wehrli, F. W., & Wang, D. J. J. (2012) · Radiology · doi:10.1148/radiol.12111509 · Cited by 108
Hendrikse, J., van Osch, M. J. P., Rutgers, D. R., Bakker, C. J. G., Kappelle, L. J., Golay, X., & van der Grond, J. (2004) · Radiology · doi:10.1148/radiol.2333031276 · Cited by 106
Self-citationArterial spin labeled MRI in prodromal Alzheimer's disease: A multi-site study
Wang, Z., Das, S. R., Xie, S. X., Arnold, S. E., Detre, J. A., & Wolk, D. A. (2013) · NeuroImage: Clinical · doi:10.1016/j.nicl.2013.04.014 · Cited by 105
New directions in clinical imaging of cortical dysplasias
Madan, N., & Grant, P. E. (2009) · Epilepsia · doi:10.1111/j.1528-1167.2009.02292.x · Cited by 105
Yoshiura, T., Hiwatashi, A., Yamashita, K., Ohyagi, Y., Monji, A., Takayama, Y., Nagao, E., Kamano, H., Noguchi, T., & Honda, H. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1562 · Cited by 104
Cortical hypoperfusion in Parkinson's disease assessed using arterial spin labeled perfusion MRI
Fernández‐Seara, M. A., Mengual, E., Vidorreta, M., Aznárez‐Sanado, M., Loayza, F. R., Villagra, F., Irigoyen, J., & Pastor, M. A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.033 · Cited by 104
Arterial Spin-Labeling and MR Spectroscopy in the Differentiation of Gliomas
Chawla, S., Wang, S., Wolf, R. L., Woo, J. H., Wang, J., O’Rourke, D. M., Judy, K. D., Grady, M. S., Melhem, E. R., & Poptani, H. (2007) · American Journal of Neuroradiology · doi:10.3174/ajnr.a0673 · Cited by 103
Static and Dynamic Characteristics of Cerebral Blood Flow During the Resting State in Schizophrenia
Kindler, J., Jann, K., Homan, P., Hauf, M., Walther, S., Strik, W., Dierks, T., & Hubl, D. (2015) · Schizophrenia Bulletin · doi:10.1093/schbul/sbt180 · Cited by 103
Regional cerebral blood flow and plasma nicotine after smoking tobacco cigarettes
Domino, E. F., Ni, L., Xu, Y., Koeppe, R. A., Guthrie, S. K., & Zubieta, J.-K. (2003) · Progress in Neuro-Psychopharmacology and Biological Psychiatry · doi:10.1016/j.pnpbp.2003.10.011 · Cited by 102
EPISTAR MRI: Multislice mapping of cerebral blood flow
Edelman, R. R., & Chen, Q. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400603 · Cited by 101
Arterial Spin Labeling: Benefits and Pitfalls of High Magnetic Field
Golay, X., & Petersen, E. T. (2006) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2006.02.003 · Cited by 99
Self-citationPersonality factors correlate with regional cerebral perfusion
Tuura, R., Kumari, V., Williams, S., Zelaya, F. O., Connor, S. E. J., Alsop, D. C., & Gray, J. A. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.12.048 · Cited by 98
Kim, S. M., Kim, M. J., Rhee, H. Y., Ryu, C., Kim, E. J., Petersen, E. T., & Jahng, G. (2012) · Neuroradiology · doi:10.1007/s00234-012-1077-x · Cited by 98
Kim, H. S., & Kim, S. Y. (2007) · American Journal of Neuroradiology · doi:10.3174/ajnr.a0674 · Cited by 97
Arterial spin labelling at 3-T MR imaging for detection of individuals with Alzheimer’s disease
Yoshiura, T., Hiwatashi, A., Noguchi, T., Yamashita, K., Ohyagi, Y., Monji, A., Nagao, E., Kamano, H., Togao, O., & Honda, H. (2009) · European Radiology · doi:10.1007/s00330-009-1511-6 · Cited by 97
Making Alzheimer's and dementia research fit for populations
Brayne, C., & Davis, D. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61803-0 · Cited by 97
Scheef, L., Manka, C., Daamen, M., Kühn, K.-U., Maier, W., Schild, H. H., & Jessen, F. (2010) · Radiology · doi:10.1148/radiol.10091224 · Cited by 97
Donahue, M. J., Lu, H., Jones, C. K., Pekar, J. J., & van Zijl, P. C. M. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1075 · Cited by 95
The efficiency of adiabatic inversion for perfusion imaging by arterial spin labeling
Maccotta, L., Detre, J. A., & Alsop, D. C. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199706/08)10:4/5<216::aid-nbm468>3.0.co;2-u · Cited by 93
Usefulness of pulsed arterial spin labeling MR imaging in mesial temporal lobe epilepsy
Lim, Y., Cho, Y., Shamim, S. A., Solomon, J. M., Birn, R. M., Luh, W., Gaillard, W. D., Ritzl, E. K., & Theodore, W. H. (2008) · Epilepsy Research · doi:10.1016/j.eplepsyres.2008.08.001 · Cited by 93
Bron, E. E., Steketee, R. M. E., Houston, G. C., Oliver, R. A., Achterberg, H. C., Loog, M., van Swieten, J. C., Hammers, A., Niessen, W. J., Smits, M., et al. (2014) · Human Brain Mapping · doi:10.1002/hbm.22522 · Cited by 93
Self-citationRegional reproducibility of pulsed arterial spin labeling perfusion imaging at 3T
Wang, Y., Saykin, A. J., Pfeuffer, J., Lin, C., Mosier, K. M., Shen, L., Kim, S., & Hutchins, G. D. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.08.043 · Cited by 91
Seizure-induced neuronal injury: Human data
Duncan, J. S. (2002) · Neurology · doi:10.1212/wnl.59.9_suppl_5.s15 · Cited by 88
Inter-Vendor Reproducibility of Pseudo-Continuous Arterial Spin Labeling at 3 Tesla
Mutsaerts, H. J. M. M., Steketee, R. M. E., Heijtel, D., Kuijer, J. P. A., van Osch, M. J. P., Majoie, C. B. L. M., Smits, M., & Nederveen, A. J. (2014) · PLoS ONE · doi:10.1371/journal.pone.0104108 · Cited by 87
Self-citationde Bastos-Leite, A. J., Kuijer, J. P. A., Rombouts, S. A. R. B., Sanz‐Arigita, E., van Straaten, E. C. W., Gouw, A. A., van der Flier, W. M., Scheltens, P., & Barkhof, F. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1091 · Cited by 85
Minimizing acquisition time of arterial spin labeling at 3T
Fernández‐Seara, M. A., Edlow, B. L., Hoang, A., Wang, J., Feinberg, D. A., & Detre, J. A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21633 · Cited by 83
Altered Cerebral Perfusion in Executive, Affective, and Motor Networks During Adolescent Depression
Ho, T. C., Wu, J., Shin, D. D., Liu, T. T., Tapert, S. F., Yang, G., Connolly, C. G., Frank, G. K. W., Max, J. E., Wolkowitz, O., et al. (2013) · Journal of the American Academy of Child & Adolescent Psychiatry · doi:10.1016/j.jaac.2013.07.008 · Cited by 81
Cost-Effectiveness of PET in the Diagnosis of Alzheimer Disease
McMahon, P. M., Araki, S. S., Sandberg, E. A., Neumann, P. J., & Gazelle, G. S. (2003) · Radiology · doi:10.1148/radiol.2282020915 · Cited by 81
Homan, P., Kindler, J., Hauf, M., Hubl, D., & Dierks, T. (2012) · Translational Psychiatry · doi:10.1038/tp.2012.114 · Cited by 80 · cited 1×
“Regional CBF measurements have been shown to predict response of patients with depression [220] and schizophrenia [221] to repetitive transcranial magnetic stimulation, indicating potential for individualised therapy.”
BackgroundLawrence, K. S., & Wang, D. J. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20364 · Cited by 80
Duhameau, B., Ferré, J.-C., Jannin, P., Gauvrit, J.-Y., Vérin, M., Millet, B., & Drapier, D. (2010) · Psychiatry Research: Neuroimaging · doi:10.1016/j.pscychresns.2010.01.009 · Cited by 80
Steketee, R. M. E., Bron, E. E., Meijboom, R., Houston, G. C., Klein, S., Mutsaerts, H. J. M. M., Mendez Orellana, C. P., de Jong, F. J., van Swieten, J. C., van der Lugt, A., et al. (2016) · European Radiology · doi:10.1007/s00330-015-3789-x · Cited by 79
Self-citationCerebral Blood Flow during Rest Associates with General Intelligence and Creativity
Takeuchi, H., Taki, Y., Hashizume, H., Sassa, Y., Nagase, T., Nouchi, R., & Kawashima, R. (2011) · PLoS ONE · doi:10.1371/journal.pone.0025532 · Cited by 79
The interaction of carbon dioxide and hypoxia in the control of cerebral blood flow
Mardimae, A., Balaban, D. Y., Machina, M. A., Han, J. S., Katznelson, R., Minkovich, L. L., Fedorko, L., Murphy, P. M., Wąsowicz, M., Naughton, F., et al. (2012) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-012-1148-1 · Cited by 79
Paling, D., Petersen, E. T., Tozer, D. J., Altmann, D. R., Wheeler‐Kingshott, C. A. M. G., Kapoor, R., Miller, D. H., & Golay, X. (2013) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2013.161 · Cited by 78
Self-citationLüdemann, L., Warmuth, C., Plotkin, M., Förschler, A., Gutberlet, M., Wust, P., & Amthauer, H. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2008.02.012 · Cited by 78
Combining ESI, ASL and PET for quantitative assessment of drug-resistant focal epilepsy
Storti, S. F., Galazzo, I. B., Felice, A. D., Pizzini, F. B., Arcaro, C., Formaggio, E., Mai, R., & Manganotti, P. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.028 · Cited by 74
Self-citationPfefferbaum, A., Chanraud, S., Pitel, A., Shankaranarayanan, A., Alsop, D. C., Rohlfing, T., & Sullivan, E. V. (2010) · Psychiatry Research Neuroimaging · doi:10.1016/j.pscychresns.2010.02.010 · Cited by 73
Mak, H. K., Chan, Q., Zhang, Z., Petersen, E. T., Qiu, D., Zhang, L., Yau, K. K. W., Chu, L., & Golay, X. (2012) · Journal of Alzheimer s Disease · doi:10.3233/jad-2012-111877 · Cited by 71
Self-citationComplex relationships between cerebral blood flow and brain atrophy in early Huntington's disease
Chen, J. J., Salat, D. H., & Rosas, H. D. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.08.112 · Cited by 69
An arterial spin labeling investigation of cerebral blood flow deficits in chronic stroke survivors
Brumm, K., Perthen, J. E., Liu, T. T., Haist, F., Ayalon, L., & Love, T. E. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.008 · Cited by 69
Liu, H., Kochunov, P., Hou, J., Pu, Y., Mahankali, S., Feng, C., Yee, S.-H., Wan, Y., Fox, P. T., & Gao, J. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200103)45:3<431::aid-mrm1056>3.0.co;2-e · Cited by 68
Hartkamp, N. S., Petersen, E. T., Vis, J. B. D., Bokkers, R. P. H., & Hendrikse, J. (2012) · NMR in Biomedicine · doi:10.1002/nbm.2836 · Cited by 67
Arterial spin labeling measurement of cerebral perfusion in children with sickle cell disease
Gevers, S., Nederveen, A. J., Fijnvandraat, K., van den Berg, S. M., van Ooij, P., Heijtel, D. F., Heijboer, H., Nederkoorn, P. J., Engelen, M., van Osch, M. J., et al. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23505 · Cited by 65
Noninvasive Cerebral Perfusion Imaging in High-Risk Neonates
Goff, D. A., Buckley, E. M., Durduran, T., Wang, J., & Licht, D. J. (2010) · Seminars in Perinatology · doi:10.1053/j.semperi.2009.10.005 · Cited by 63
Wolf, R. C., Grön, G., Sambataro, F., Vasic, N., Wolf, N. D., Thomann, P. A., Saft, C., Landwehrmeyer, G. B., & Orth, M. (2011) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2011.60 · Cited by 62
Anoxic Injury-Associated Cerebral Hyperperfusion Identified with Arterial Spin-Labeled MR Imaging
Pollock, J. M., Whitlow, C. T., Deibler, A. R., Tan, H., Burdette, J. H., Kraft, R., & Maldjian, J. A. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1095 · Cited by 62
Ota, M., Sato, N., Nakata, Y., Ito, K., Kamiya, K., Maikusa, N., Ogawa, M., Okamoto, T., Obu, S., Noda, T., et al. (2013) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2013.03.016 · Cited by 60
Uchihashi, Y., Hosoda, K., Zimine, I., Fujita, A., Fujii, M., Sugimura, K., & Kohmura, E. (2011) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2525 · Cited by 59
Hirai, T., Kitajima, M., Nakamura, H., Okuda, T., Sasao, A., Shigematsu, Y., Utsunomiya, D., Oda, S., Uetani, H., Morioka, M., et al. (2011) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2725 · Cited by 59
Perfusion Magnetic Resonance Imaging in Psychiatry
Théberge, J. (2008) · Topics in Magnetic Resonance Imaging · doi:10.1097/rmr.0b013e3181808140 · Cited by 57
Khalili‐Mahani, N., Niesters, M., van Osch, M. J. P., Oitzl, M. S., Veer, I. M., de Rooij, M., van Gerven, J., van Buchem, M. A., Beckmann, C. F., Rombouts, S. A. R. B., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.12.050 · Cited by 55
Wolf, R. C., Thomann, P. A., Sambataro, F., Vasic, N., Schmid, M., & Wolf, N. D. (2012) · European Archives of Psychiatry and Clinical Neuroscience · doi:10.1007/s00406-012-0303-1 · Cited by 54
Colloby, S. J., Firbank, M., He, J., Thomas, A. J., Vasudev, A., Parry, S. W., & O'Brien, J. T. (2012) · The British Journal of Psychiatry · doi:10.1192/bjp.bp.111.092387 · Cited by 53
Kanazawa, Y., Morioka, T., Arakawa, S., Furuta, Y., Nakanishi, A., & Kitazono, T. (2015) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2014.09.026 · Cited by 50
Wang, Z. (2014) · Journal of Alzheimer s Disease · doi:10.3233/jad-141419 · Cited by 45
Mutsaerts, H. J. M. M., Richard, E., Heijtel, D., van Osch, M. J. P., Majoie, C. B. L. M., & Nederveen, A. J. (2013) · NeuroImage Clinical · doi:10.1016/j.nicl.2013.11.003 · Cited by 43
Reliability and reproducibility of perfusion MRI in cognitively normal subjects
Jiang, L., Kim, M., Chodkowski, B., Donahue, M. J., Pekar, J. J., van Zijl, P. C. M., & Albert, M. (2010) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2010.05.002 · Cited by 42
Pienaar, R., Paldino, M. J., Madan, N., Krishnamoorthy, K. S., Alsop, D. C., Dehaes, M., & Grant, P. E. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.07.062 · Cited by 41
Arterial spin labeling and altered cerebral blood flow patterns in the minimally conscious state
Liu, A. A., Voss, H. U., Dyke, J. P., Heier, L., & Schiff, N. D. (2011) · Neurology · doi:10.1212/wnl.0b013e318233b229 · Cited by 40
Prefrontal cortical blood flow predicts response of depression to rTMS
Weiduschat, N., & Dubin, M. J. (2013) · Journal of Affective Disorders · doi:10.1016/j.jad.2013.04.049 · Cited by 38
Raji, C. A., Lee, C., López, O. L., Tsay, J., Boardman, J. F., Schwartz, E. D., Bartynski, W. S., Hefzy, H., Gach, H. M., Dai, W., et al. (2010) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1955 · Cited by 37
Acquisition Time and Reproducibility of Continuous Arterial Spin-Labeling Perfusion Imaging at 3T
Gevers, S., Majoie, C. B. L. M., van den Tweel, X. W., Lavini, C., & Nederveen, A. J. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1454 · Cited by 36
Paradiso, S. (2003) · Journal of Neuropsychiatry · doi:10.1176/appi.neuropsych.15.1.35 · Cited by 33
Zhang, Q., Stafford, R. B., Wang, Z., Arnold, S. E., Wolk, D. A., & Detre, J. A. (2012) · Journal of Alzheimer s Disease · doi:10.3233/jad-2012-120964 · Cited by 32
Siero, J. C. W., Hartkamp, N. S., Donahue, M. J., Harteveld, A. A., Compter, A., Petersen, E. T., & Hendrikse, J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.09.033 · Cited by 31
Saida, T., Masumoto, T., Nakai, Y., Shiigai, M., Matsumura, A., & Minami, M. (2012) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0b013e31824150dd · Cited by 29
Dashjamts, T., Yoshiura, T., Hiwatashi, A., Yamashita, K., Monji, A., Ohyagi, Y., Kamano, H., Kawashima, T., Kira, J., & Honda, H. (2011) · Academic Radiology · doi:10.1016/j.acra.2011.07.015 · Cited by 24
Hartkamp, N. S., Helle, M., Chappell, M. A., Okell, T. W., Hendrikse, J., Bokkers, R. P. H., & van Osch, M. J. P. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24872 · Cited by 22
Nordin, L. E., Li, T., Brogren, J., Johansson, P., Sjögren, N., Hannesdóttir, K., Björk, C., Segerdahl, M., Wang, D. J. J., & Julin, P. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.11.035 · Cited by 22
Die zerebrovaskuläre Reservekapazität
Stol, M., & Hamann, G. F. (2002) · Der Nervenarzt · doi:10.1007/s00115-002-1313-4 · Cited by 19
Differential Diagnostic Approach to MR Imaging of White Matter Diseases
Hesselink, J. R. (2006) · Topics in Magnetic Resonance Imaging · doi:10.1097/01.rmr.0000248666.91834.af · Cited by 12
Cited by
Microscopic brain tumor detection and classification using 3D CNN and feature selection architecture
Rehman, A., Khan, M. A., Saba, T., Mehmood, Z., Tariq, U., & Ayesha, N. (2021) · Microscopy Research and Technique · doi:10.1002/jemt.23597 · Cited by 317
Pseudoprogression of brain tumors
Thust, S. C., van den Bent, M. J., & Smits, M. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26171 · Cited by 304
Self-citationBrain metastases: neuroimaging
(2018) · Handbook of Clinical Neurology · doi:10.1016/b978-0-12-811161-1.00007-4 · Cited by 223
“Mean transit time of blood through tissue also can be acquired (Grade et al., 2015).”
BackgroundZhang, N., Gordon, M. L., & Goldberg, T. E. (2017) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2016.11.023 · Cited by 182
“It was also found that the reduced CBF correlated with evidence of cerebrovascular disease on structural MRI in the elderly, such as the volume of white matter hyperintensities (Crane et al., 2015) and cortical microbleeds (Gregg et al., 2015).”
Calderón-Garcidueñas, L., Reynoso-Robles, R., Vargas- Martínez, J., Gómez-Maqueo-Chew, A., Pérez-Guillé, B., Mukherjee, P. S., Torres-Jardón, R., Perry, G., & Gónzalez-Maciel, A. (2016) · Environmental Research · doi:10.1016/j.envres.2015.12.031 · Cited by 179
Metadata
- Authors
- Grade, M., Hernandez Tamames, J. A., Pizzini, F. B., Achten, E., Golay, X., & Smits, M.
- Venue
- Neuroradiology
- Published
- 2015-09-09
- Volume
- 57
- Issue
- 12
- Pages
- 1181-1202
- ISSN
- 0028-3940 (ISSN-L)
- 1432-1920
- OpenAlex
- W1773336933
- Cited by
- 298
- References
- 164
- FWCI
- 15.27
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.