Native Mass Spectrometry: What is in the Name?
Open accessThe DOI matches its Crossref record; 88 of the 89 references it cites were found in a registry or an index.
Abstract
Electrospray ionization mass spectrometry (ESI-MS) is nowadays one of the cornerstones of biomolecular mass spectrometry and proteomics. Advances in sample preparation and mass analyzers have enabled researchers to extract much more information from biological samples than just the molecular weight. In particular, relevant for structural biology, noncovalent protein-protein and protein-ligand complexes can now also be analyzed by MS. For these types of analyses, assemblies need to be retained in their native quaternary state in the gas phase. This initial small niche of biomolecular mass spectrometry, nowadays often referred to as "native MS," has come to maturation over the last two decades, with dozens of laboratories using it to study mostly protein assemblies, but also DNA and RNA-protein assemblies, with the goal to define structure-function relationships. In this perspective, we describe the origins of and (re)define the term native MS, portraying in detail what we meant by "native MS," when the term was coined and also describing what it does (according to us) not entail. Additionally, we describe a few examples highlighting what native MS is, showing its successes to date while illustrating the wide scope this technology has in solving complex biological questions. Graphical Abstract ᅟ.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



![Figure 3 Native MS compares well with alternative methods to probe quaternary structures. (a) Cartoon of the wild-type IgG4 antibody and an IgG4 antibody whereby the hinge region is deleted (IgG4Δhinge). IgG4Δhinge exists in solution in equilibrium between its monomeric (HL) and dimeric (HL2) state. (b) Native MS of three HL mutants; IgG4Δhinge, R409KΔhinge, and F405QΔhinge. Two charge state distributions are observed for IgG4Δhinge corresponding to its monomeric and dimeric state, well separated in m/z space. In contrast, predominantly the monomeric and dimeric states were observed for the IgG4Δhinge variants F405Q and R409K, respectively. (c) Native PAGE of IgG4Δhinge, R409KΔhinge, and F405QΔhinge, showing different band migrations corresponding to the oligomeric status (i.e., monomeric/dimeric) of the variants in solution. (d) Size exclusion chromatography (SEC) multi-angle laser light scattering (MALLS) of IgG4Δhinge (red), R409KΔhinge (green), and F405QΔhinge (blue), showing the difference in retention times/molar masses measured reflecting their either monomeric, dimeric, or mixed status in solution [81]. The figure is adapted from [81]](https://figures.cochat.ai/paper-figures/0832cbff789c4a8cbfe8b447563db8f5/native-mass-spectrometry-what-is-in-the-name-figure-3.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Since CE separations can be performed in aqueous buffers, protein complexes can be separated in their native structures, preserving non-covalent interactions within a protein and between subunits of protein assemblies, prior to MS detection19–21.”
From Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research (2019) · cites this paper as [20]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The success of native MS approaches relies on ESI of proteins in a volatile aqueous buffer that preserves native quaternary and tertiary states in the gas phase19,20.”
From Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research (2019) · cites this paper as [20]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Native MS can be used to interrogate the structure of intact proteins in their near native state, with an emphasis on preserving noncovalent protein-protein and protein-ligand complexes20.”
From Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research (2019) · cites this paper as [20]
In the citing paper
“Briefly, native top-down MS involves using non-denaturing conditions and often employing 100–200 mM ammonium acetate as a volatile buffer for the analysis of intact proteins and protein complexes.”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [40]
In the citing paper
“Native MS provides a proteomics tool that enables identification and characterization of these biomolecular structures and advances the understanding of their biological pathways at the molecular level19,20,35.”
From Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research (2019) · cites this paper as [20]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634 · cited 14×
“Thus, an unfolded/ less structured protein in its most expanded form (i.e., in acidified organic solvent) will pick up more charges during ESI than a folded/more structured protein (i.e., electrosprayed from aqueous solution).”
BackgroundMethodInfluentialProtein and polymer analyses up to m/z 100 000 by laser ionization time‐of‐flight mass spectrometry
Tanaka, K., Waki, H., Ido, Y., Akita, S., Yoshida, Y., Yoshida, T., & Matsuo, T. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290020802 · Cited by 3,175 · cited 3×
“In MALDI, the analyte of interest is co-crystalized with IR- or UV-absorbing organic acids and laser ablation used to transfer the sample into the gas phase for analysis.”
MethodA generic protein purification method for protein complex characterization and proteome exploration
Rigaut, G., Shevchenko, A., Rutz, B., Wilm, M., Mann, M., & Séraphin, B. (1999) · Nature Biotechnology · doi:10.1038/13732 · Cited by 2,707 · cited 1×
“Tandem affinity purification [86] techniques are continuing to improve, and thus the challenges associated with extracting pristine cell-derived assemblies in high enough concentrations for native MS analysis are slowly being overcome.”
BackgroundAnalytical Properties of the Nanoelectrospray Ion Source
Wilm, M., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac9509519 · Cited by 1,868 · cited 1×
“This lower flow rate ESI, termed nanoESI [35], is highly advantageous for native MS analysis because of its low sample consumption, more uniform response factors, and higher tolerance to salts and buffers.”
BackgroundThe BioPlex network: a systematic exploration of the human interactome
Huttlin, E. L., Ting, L., Bruckner, R. J., Gebreab, F., Gygi, M. P., Szpyt, J., Tam, S., Zarraga, G., Colby, G., Baltier, K., et al. (2015) · Cell · doi:10.1016/j.cell.2015.06.043 · Cited by 1,425 · cited 3×
“Mass spectrometry (MS), specifically MS-based proteomics, has already played a pivotal role in deciphering the many protein complexes and protein interaction networks that are present in the cell, typically at the end of a pipe-line that starts with the immune-purification of a tagged-bait protein, followed by identif…”
BackgroundMethodA Human Interactome in Three Quantitative Dimensions Organized by Stoichiometries and Abundances
Hein, M. Y., Hubner, N. C., Poser, I., Cox, J., Nagaraj, N., Toyoda, Y., Gak, I. A., Weisswange, I., Mansfeld, J., Buchholz, F., et al. (2015) · Cell · doi:10.1016/j.cell.2015.09.053 · Cited by 1,270 · cited 3×
“Mass spectrometry (MS), specifically MS-based proteomics, has already played a pivotal role in deciphering the many protein complexes and protein interaction networks that are present in the cell, typically at the end of a pipe-line that starts with the immune-purification of a tagged-bait protein, followed by identif…”
BackgroundMethodStudying noncovalent protein complexes by electrospray ionization mass spectrometry
Loo, J. A. (1997) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1997)16:1<1::aid-mas1>3.0.co;2-l · Cited by 1,182
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905 · cited 13×
“Thus, an unfolded/ less structured protein in its most expanded form (i.e., in acidified organic solvent) will pick up more charges during ESI than a folded/more structured protein (i.e., electrosprayed from aqueous solution).”
MethodInfluentialLanucara, F., Holman, S. W., Gray, C. J., & Eyers, C. E. (2014) · Nature Chemistry · doi:10.1038/nchem.1889 · Cited by 901 · cited 1×
“Perhaps even more convincing arguments that protein structures can be partly retained in the gas phase come from more recent ion mobility spectrometry (IMS) experiments [62, 63].”
BackgroundMembrane proteins bind lipids selectively to modulate their structure and function
Laganowsky, A., Reading, E., Allison, T. M., Ulmschneider, M. B., Degiacomi, M. T., Baldwin, A. J., & Robinson, C. V. (2014) · Nature · doi:10.1038/nature13419 · Cited by 781 · cited 2×
“Overall, although the debate whether native protein structure is maintained in the gas phase continues, the future is bright for structural MS analysis of proteins and their complexes, as illustrated by a growing body of work of, for instance, protein–lipid [26, 74, 75], protein–RNA [76], protein– 8 A.”
BackgroundNative mass spectrometry: a bridge between interactomics and structural biology
Heck, A. J. R. (2008) · Nature Methods · doi:10.1038/nmeth.1265 · Cited by 766
Self-citationDetermining the stoichiometry and interactions of macromolecular assemblies from mass spectrometry
Hernández, H., & Robinson, C. V. (2007) · Nature Protocols · doi:10.1038/nprot.2007.73 · Cited by 655 · cited 1×
“modified their quadrupole (Q)-ToF mass spectrometers [40, 41], which together with elegant work on the optimization and transmission of high m/z ions [42, 43], enabled tandem MS experiments to be performed on large protein complexes, providing information not only on protein complex stoichiometry but also on protein c…”
BackgroundEvidence for Macromolecular Protein Rings in the Absence of Bulk Water
Ruotolo, B. T., Giles, K., Campuzano, I., Sandercock, A. M., Bateman, R. H., & Robinson, C. V. (2005) · Science · doi:10.1126/science.1120177 · Cited by 596
Investigation of intact protein complexes by mass spectrometry
Heck, A. J. R., & van den Heuvel, R. H. H. (2004) · Mass Spectrometry Reviews · doi:10.1002/mas.10081 · Cited by 583 · cited 1×
“DNA [77], protein–drug [78], and protein–protein complexes [79, 80].”
Self-citationProgress in Top-Down Proteomics and the Analysis of Proteoforms
Toby, T. K., Fornelli, L., & Kelleher, N. L. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041550 · Cited by 576 · cited 1×
“The future of MS-based structural biology is certainly also hybrid, as native MS should be and is being more and more combined with complementary methods such as top-down and middle-down proteomics [89], cross-linking MS, covalent labeling MS, and hydrogen/deuterium exchange MS [9].”
MethodStructural characterization of proteins and complexes using small-angle X-ray solution scattering
Mertens, H. D. T., & Svergun, D. I. (2010) · Journal of Structural Biology · doi:10.1016/j.jsb.2010.06.012 · Cited by 567 · cited 1×
“croscopy [7] and small angle scattering [8] excel.”
BackgroundFernandez de la Mora, J. (2000) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00601-7 · Cited by 528 · cited 1×
“This observation was rationalized by the fact that during the ESI process, assuming the charge residue model [60], only solvent exposed basic residues could pick up a charge/proton.”
MethodOrbitrap mass spectrometry: Instrumentation, ion motion and applications
Perry, R. H., Cooks, R. G., & Noll, R. J. (2008) · Mass Spectrometry Reviews · doi:10.1002/mas.20186 · Cited by 514 · cited 1×
“Addressing these issues, an Orbitrap mass analyzer [51] modified for the transmission of ions in the highm/z range was introduced for nativeMS analysis in 2012 [52].”
MethodA Tandem Mass Spectrometer for Improved Transmission and Analysis of Large Macromolecular Assemblies
Sobott, F., Hernández, H., McCammon, M. G., Tito, M. A., & Robinson, C. V. (2002) · Analytical Chemistry · doi:10.1021/ac0110552 · Cited by 511 · cited 1×
“modified their quadrupole (Q)-ToF mass spectrometers [40, 41], which together with elegant work on the optimization and transmission of high m/z ions [42, 43], enabled tandem MS experiments to be performed on large protein complexes, providing information not only on protein complex stoichiometry but also on protein c…”
BackgroundDetection of noncovalent receptor-ligand complexes by mass spectrometry
Ganem, B., Li, Y. T., & Henion, J. D. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00016a069 · Cited by 506 · cited 1×
“The latter arose following initial work by a few laboratories in the 1990s [10, 11], demonstrating that noncovalent interactions could be preserved in the gas phase for analysis, enabling information on subunit stoichiometry, binding partners, protein complex topology, protein dynamics, and even binding affinities fro…”
BackgroundInfluentialDaniel, J. M., Friess, S. D., Rajagopalan, S., Wendt, S., & Zenobi, R. (2002) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(02)00585-7 · Cited by 475 · cited 1×
“Thus, native MS provides complementarity information to other biochemical techniques, making it highly suitable for the structural characterization of proteins and their complexes, and the qualitative and even sometimes quantitative analysis of binding affinities [14, 83].”
BackgroundKatta, V., & Chait, B. T. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00022a058 · Cited by 475 · cited 1×
“The latter arose following initial work by a few laboratories in the 1990s [10, 11], demonstrating that noncovalent interactions could be preserved in the gas phase for analysis, enabling information on subunit stoichiometry, binding partners, protein complex topology, protein dynamics, and even binding affinities fro…”
BackgroundInfluentialMorris, H. R., Paxton, T., Dell, A., Langhorne, J., Berg, M., Bordoli, R. S., Hoyes, J., & Bateman, R. H. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19960610)10:8<889::aid-rcm615>3.0.co;2-f · Cited by 446
High-sensitivity Orbitrap mass analysis of intact macromolecular assemblies
Rose, R. J., Damoc, E., Denisov, E., Makarov, A., & Heck, A. J. R. (2012) · Nature Methods · doi:10.1038/nmeth.2208 · Cited by 392 · cited 1×
“Addressing these issues, an Orbitrap mass analyzer [51] modified for the transmission of ions in the highm/z range was introduced for nativeMS analysis in 2012 [52].”
MethodSelf-citationBleiholder, C., Dupuis, N. F., Wyttenbach, T., & Bowers, M. T. (2011) · Nature Chemistry · doi:10.1038/nchem.945 · Cited by 366
Micelles Protect Membrane Complexes from Solution to Vacuum
Barrera, N. P., Di Bartolo, N., Booth, P. J., & Robinson, C. V. (2008) · Science · doi:10.1126/science.1159292 · Cited by 360 · cited 2×
“In the work by the Robinson group, n-dodecyl-β-D-maltoside micelles were used to protect the heteromeric adenosine 5′-triphosphate-binding cassette transporter BtuC2D2 upon transition from solution into the gas phase, whereby the intact mass of both the intact complex and dissociated subunits could be measured [47].”
BackgroundMethodThe Role of Mass Spectrometry in Structure Elucidation of Dynamic Protein Complexes
Sharon, M., & Robinson, C. V. (2007) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.76.061005.090816 · Cited by 357
Jurneczko, E., & Barran, P. E. (2011) · The Analyst · doi:10.1039/c0an00373e · Cited by 328 · cited 1×
“Perhaps even more convincing arguments that protein structures can be partly retained in the gas phase come from more recent ion mobility spectrometry (IMS) experiments [62, 63].”
BackgroundMass spectrometry for structural characterization of therapeutic antibodies
Zhang, Z., Pan, H., & Chen, X. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20190 · Cited by 316 · cited 1×
“With the growing demand for MS analysis of macromolecular complexes both in the area of structural biology and in the biopharmaceutical industry [50], the need for more sensitive, higher resolution instruments increased.”
BackgroundNative protein mass spectrometry: from intact oligomers to functional machineries
Heuvel, R. H. V. D., & Heck, A. J. (2004) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2004.08.006 · Cited by 303 · cited 1×
“The term native MS was coined in 2004 [15]; however, it described approaches that had been introduced earlier [10, 18–20].”
MethodSelf-citationCryo-electron microscopy--a primer for the non-microscopist
Milne, J. L. S., Borgnia, M. J., Bartesaghi, A., Tran, E. E. H., Earl, L. A., Schauder, D. M., Lengyel, J., Pierson, J., Patwardhan, A., & Subramaniam, S. (2013) · The FEBS Journal · doi:10.1111/febs.12078 · Cited by 277 · cited 1×
“croscopy [7] and small angle scattering [8] excel.”
BackgroundInterrogating viral capsid assembly with ion mobility–mass spectrometry
Uetrecht, C., Barbu, I. M., Shoemaker, G. K., van Duijn, E., & Heck, A. J. R. (2011) · Nature Chemistry · doi:10.1038/nchem.947 · Cited by 267
Self-citationCollision cross sections for protein ions
Covey, T., & Douglas, D. J. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85025-s · Cited by 253
van den Heuvel, R. H. H., van Duijn, E., Mazon, H., Synowsky, S. A., Lorenzen, K., Versluis, C., Brouns, S. J. J., Langridge, D., van der Oost, J., Hoyes, J., et al. (2006) · Analytical Chemistry · doi:10.1021/ac061039a · Cited by 252 · cited 1×
“modified their quadrupole (Q)-ToF mass spectrometers [40, 41], which together with elegant work on the optimization and transmission of high m/z ions [42, 43], enabled tandem MS experiments to be performed on large protein complexes, providing information not only on protein complex stoichiometry but also on protein c…”
BackgroundSelf-citationKitova, E. N., El-Hawiet, A., Schnier, P. D., & Klassen, J. S. (2012) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-011-0311-9 · Cited by 237
Verentchikov, A. N., Ens, W., & Standing, K. G. (1994) · Analytical Chemistry · doi:10.1021/ac00073a022 · Cited by 223 · cited 1×
“On the other hand, time-of-flight (ToF) mass analyzers have no theoretical upper mass range, and can achieve high sensitivity and resolution on a fast timescale [38].”
BackgroundThe diverse and expanding role of mass spectrometry in structural and molecular biology
Lössl, P., van de Waterbeemd, M., & Heck, A. J. (2016) · The EMBO Journal · doi:10.15252/embj.201694818 · Cited by 222 · cited 2×
“The future of MS-based structural biology is certainly also hybrid, as native MS should be and is being more and more combined with complementary methods such as top-down and middle-down proteomics [89], cross-linking MS, covalent labeling MS, and hydrogen/deuterium exchange MS [9].”
BackgroundMethodSelf-citationDetection and selective dissociation of intact ribosomes in a mass spectrometer
Rostom, A. A., Fucini, P., Benjamin, D. R., Juenemann, R., Nierhaus, K. H., Hartl, F. U., Dobson, C. M., & Robinson, C. V. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.10.5185 · Cited by 209 · cited 1×
“, the ribosome [25]), protein–lipid complexes such as transport channels [26], nucleic acid structures such as DNA G-quadruplexes [27], and noncovalent drug– nucleic acids interactions [28].”
BackgroundMass spectrometry and viral analysis
Siuzdak, G., Bothner, B., Yeager, M., Brugidou, C., Fauquet, C. M., Hoey, K., & Change, C.-M. (1996) · Chemistry & Biology · doi:10.1016/s1074-5521(96)90083-6 · Cited by 203 · cited 1×
“addressed this issue by using soft landing experiments whereby the tobacco mosaic virus was electrosprayed from solution and subsequently captured and visualized by transmission electron microscopy [61].”
MethodMass Spectrometry of Protein Complexes: From Origins to Applications
Mehmood, S., Allison, T. M., & Robinson, C. V. (2015) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-040214-121732 · Cited by 199 · cited 1×
“DNA [77], protein–drug [78], and protein–protein complexes [79, 80].”
Studying 18 MDa Virus Assemblies with Native Mass Spectrometry
Snijder, J., Rose, R. J., Veesler, D., Johnson, J. E., & Heck, A. J. R. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201210197 · Cited by 193
Self-citationIon Mobility Analysis of Molecular Dynamics
Wyttenbach, T., Pierson, N. A., Clemmer, D. E., & Bowers, M. T. (2014) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-040513-103644 · Cited by 189 · cited 1×
“Since then, IMS-MS has been successfully applied to monitor protein conformational changes [67, 68] and to gain information on how proteins assemble/misassemble into large macromolecular complexes [69–71].”
MethodProtein Analysis and Purification
Rosenberg, I. M. (1996) · doi:10.1007/978-1-4612-2056-5 · Cited by 172
Characterizing Protein–Protein Interactions Using Mass Spectrometry: Challenges and Opportunities
Smits, A. H., & Vermeulen, M. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.02.014 · Cited by 167 · cited 1×
“Increased fundamental knowledge on these complex cellular interactomes is crucial for not only mapping novel interactions [1] but also for drug design [2] and integrating novel technologies for disease diagnostics [3, 4].”
BackgroundSun, J., Kitova, E. N., Wang, W., & Klassen, J. S. (2006) · Analytical Chemistry · doi:10.1021/ac0522005 · Cited by 160 · cited 1×
“For the latter, careful analysis is required as nonspecific association may occur during the ionization process for some systems, especially when the analyte concentrations are high and/or the binding affinities low [84, 85].”
BackgroundDetergent-free mass spectrometry of membrane protein complexes
Hopper, J. T. S., Yu, Y. T.-C., Li, D., Raymond, A., Bostock, M., Liko, I., Mikhailov, V., Laganowsky, A., Benesch, J. L. P., Caffrey, M., et al. (2013) · Nature Methods · doi:10.1038/nmeth.2691 · Cited by 155
Rosati, S., Yang, Y., Barendregt, A., & Heck, A. J. R. (2014) · Nature Protocols · doi:10.1038/nprot.2014.057 · Cited by 153
Self-citationMass spectrometry for the biophysical characterization of therapeutic monoclonal antibodies
Zhang, H., Cui, W., & Gross, M. L. (2014) · FEBS Letters · doi:10.1016/j.febslet.2013.11.027 · Cited by 152 · cited 1×
“Increased fundamental knowledge on these complex cellular interactomes is crucial for not only mapping novel interactions [1] but also for drug design [2] and integrating novel technologies for disease diagnostics [3, 4].”
BackgroundChaperonin Complexes Monitored by Ion Mobility Mass Spectrometry
Duijn, E. V., Barendregt, A., Synowsky, S., Versluis, C., & Heck, A. J. R. (2009) · Journal of the American Chemical Society · doi:10.1021/ja8055134 · Cited by 152
Self-citationYang, Y., Liu, F., Franc, V., Halim, L. A., Schellekens, H., & Heck, A. J. R. (2016) · Nature Communications · doi:10.1038/ncomms13397 · Cited by 152 · cited 1×
“One striking example is the analysis of erythropoietin, whereby 236 glycan proteoforms were separated by m/z and identified [57].”
MethodSelf-citationElectrospray mass spectrometry to study drug-nucleic acids interactions
Rosu, F., Pauw, E. D., & Gabelica, V. (2008) · Biochimie · doi:10.1016/j.biochi.2008.01.005 · Cited by 148 · cited 1×
“, the ribosome [25]), protein–lipid complexes such as transport channels [26], nucleic acid structures such as DNA G-quadruplexes [27], and noncovalent drug– nucleic acids interactions [28].”
BackgroundSmith, D. P., Giles, K., Bateman, R. H., Radford, S. E., & Ashcroft, A. E. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.09.017 · Cited by 132 · cited 1×
“Since then, IMS-MS has been successfully applied to monitor protein conformational changes [67, 68] and to gain information on how proteins assemble/misassemble into large macromolecular complexes [69–71].”
MethodHogan, C. J., Ruotolo, B. T., Robinson, C. V., & Fernandez de la Mora, J. (2011) · The Journal of Physical Chemistry B · doi:10.1021/jp109172k · Cited by 124
Winger, B. E., Light‐Wahl, K. J., Loo, R. R. O., Udseth, H. R., & Smith, R. D. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85015-p · Cited by 120 · cited 1×
“This m/z range was subsequently increased by the introduction of quadrupoles that operated at a lower radiofrequency [36, 37]; however, the high m/z range was compromised by a lower resolving power.”
BackgroundDetection of intact megaDalton protein assemblies of vanillyl‐alcohol oxidase by mass spectrometry
Van Berkel, W. J. H., Van Den Heuvel, R. H. H., Versluis, C., & Heck, A. J. R. (2000) · Protein Science · doi:10.1110/ps.9.3.435 · Cited by 116 · cited 1×
“modified their quadrupole (Q)-ToF mass spectrometers [40, 41], which together with elegant work on the optimization and transmission of high m/z ions [42, 43], enabled tandem MS experiments to be performed on large protein complexes, providing information not only on protein complex stoichiometry but also on protein c…”
BackgroundSelf-citationMass spectrometry of ribosomes and ribosomal subunits
Benjamin, D. R., Robinson, C. V., Hendrick, J. P., Hartl, F. U., & Dobson, C. M. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.13.7391 · Cited by 111 · cited 1×
“modified their quadrupole (Q)-ToF mass spectrometers [40, 41], which together with elegant work on the optimization and transmission of high m/z ions [42, 43], enabled tandem MS experiments to be performed on large protein complexes, providing information not only on protein complex stoichiometry but also on protein c…”
BackgroundFitzgerald, M. C., Chernushevich, I., Standing, K. G., Whitman, C. P., & Kent, S. B. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.14.6851 · Cited by 97 · cited 1×
“One key pioneering example was the analysis of the enzyme 4-oxalocrotonate tautomerase [39], which upon ESI-MS analysis confirmed the oligomeric status of the enzyme, one of the leading examples at the time that native protein structures could be preserved into the gas phase for analysis.”
Single‐molecule mass spectrometry
Keifer, D. Z., & Jarrold, M. F. (2017) · Mass Spectrometry Reviews · doi:10.1002/mas.21495 · Cited by 96 · cited 1×
“Of final note, charge detection MS (CDMS) has also expanded the range of protein complexes that can be analyzed by MS [58].”
BackgroundMass Spectrometry-based Diagnostics: The Upcoming Revolution in Disease Detection
Petricoin, E. F., & Liotta, L. A. (2003) · Clinical Chemistry · doi:10.1373/49.4.533 · Cited by 94 · cited 1×
“Increased fundamental knowledge on these complex cellular interactomes is crucial for not only mapping novel interactions [1] but also for drug design [2] and integrating novel technologies for disease diagnostics [3, 4].”
BackgroundHow far can we go with structural mass spectrometry of protein complexes?
Sharon, M. (2010) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.12.017 · Cited by 93
Arndt, C., Koristka, S., Bartsch, H., & Bachmann, M. P. (2012) · Methods in molecular biology · doi:10.1007/978-1-61779-821-4_5 · Cited by 91 · cited 1×
“Two types of PAGE conditions are typically used; denaturing PAGE whereby samples are typically reduced and heat denatured prior to analysis, and native PAGE whereby the analytes’ natural quaternary structure is maintained [22].”
MethodNative Electrospray Mass Spectrometry of DNA G-Quadruplexes in Potassium Solution
Marchand, A., & Gabelica, V. (2014) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-014-0890-3 · Cited by 86 · cited 2×
“, the ribosome [25]), protein–lipid complexes such as transport channels [26], nucleic acid structures such as DNA G-quadruplexes [27], and noncovalent drug– nucleic acids interactions [28].”
BackgroundRose, R., Labrijn, A. F., van den Bremer, E. T. J., Loverix, S., Lasters, I., van Berkel, P. H. C., van de Winkel, J. G. J., Schuurman, J., Parren, P. W. H. I., & Heck, A. J. R. (2011) · Structure · doi:10.1016/j.str.2011.06.016 · Cited by 85 · cited 3×
“affinity between the CH3 domains in the dimeric HL2 complex [81].”
BackgroundInfluentialSelf-citationRNA and protein 3D structure modeling: similarities and differences
Rother, K., Rother, M., Boniecki, M., Puton, T., & Bujnicki, J. M. (2011) · Journal of Molecular Modeling · doi:10.1007/s00894-010-0951-x · Cited by 85 · cited 1×
“Moreover, we foresee that this area of MS analysis will only continue to expand as, for instance, the analysis of RNA and DNA tertiary structures is still complex and much less explored [29].”
BackgroundRosati, S., van den Bremer, E. T., Schuurman, J., Parren, P. W., Kamerling, J. P., & Heck, A. J. (2013) · mAbs · doi:10.4161/mabs.26282 · Cited by 81 · cited 1×
“This increased resolving power has enabled small differences in proteoforms, such as glycosylation on antibodies [53, 54] and phosphorylation on proteins and protein complexes [55, 56], to be more readily resolved.”
BackgroundSelf-citationWang, W., Kitova, E. N., & Klassen, J. S. (2005) · Analytical Chemistry · doi:10.1021/ac048433y · Cited by 78
Veenstra, T. D. (1999) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.1998.0103 · Cited by 75 · cited 5×
“All cellular biological processes involve the complex coor-dination of proteins and other biomolecules (e.g., DNA, RNA, lipids, metabolites) in space and time.”
InfluentialNative Mass Spectrometry in Fragment-Based Drug Discovery
Pedro, L., & Quinn, R. (2016) · Molecules · doi:10.3390/molecules21080984 · Cited by 72 · cited 1×
“DNA [77], protein–drug [78], and protein–protein complexes [79, 80].”
Steven, A. C., & Baumeister, W. P. (2008) · Journal of Structural Biology · doi:10.1016/j.jsb.2008.06.002 · Cited by 71 · cited 1×
“The future of structural biology is hybrid [87, 88], indicating that the ideal studies on protein structure combine data of electron microscopy, X-ray crystallography, NMR spectroscopy, and other methods.”
BackgroundGas-Phase FRET Efficiency Measurements To Probe the Conformation of Mass-Selected Proteins
Czar, M. F., Zosel, F., König, I., Nettels, D., Wunderlich, B., Schuler, B., Zarrine‐Afsar, A., & Jockusch, R. A. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01591 · Cited by 63 · cited 3×
“Exceptions do exist, whereby proteins either unfold in the gas phase because of coulombic repulsion [72] or, alternatively, form more compact partly collapsed structures, a phenomenon termed gas-phase collapse [73].”
BackgroundMethodInfluentialMass spectrometric methods to analyze the structural organization of macromolecular complexes
Rajabi, K., Ashcroft, A. E., & Radford, S. E. (2015) · Methods · doi:10.1016/j.ymeth.2015.03.004 · Cited by 61
Contribution of Domain Interface Residues to the Stability of Antibody CH3 Domain Homodimers
Dall’Acqua, W. F., Simon, A. L., Mulkerrin, M. G., & Carter, P. M. (1998) · Biochemistry · doi:10.1021/bi980270i · Cited by 60 · cited 1×
“After removal of the hinge region, HL are present in an equilibrium between their monomeric and dimeric states [82].”
BackgroundImproved Elution Conditions for Native Co-Immunoprecipitation
Antrobus, R., & Borner, G. H. H. (2011) · PLoS ONE · doi:10.1371/journal.pone.0018218 · Cited by 58 · cited 1×
“Likewise, the term native is also used to describe certain immunoprecipitation assays [23, 24].”
BackgroundAmphipathic Polymers Enable the Study of Functional Membrane Proteins in the Gas Phase
Leney, A. C., McMorran, L. M., Radford, S. E., & Ashcroft, A. E. (2012) · Analytical Chemistry · doi:10.1021/ac302223s · Cited by 57 · cited 1×
“Nowadays, with the application of alternative solubilization techniques such as Amphipols [48] and Nanodiscs [49], the analysis of membrane proteins by native MS has become more widespread with studies of over 30 membrane proteins/ membrane protein complexes being reported to date.”
BackgroundSelf-citationInvestigation of protein–RNA interactions by mass spectrometry—Techniques and applications
Schmidt, C., Kramer, K., & Urlaub, H. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.04.030 · Cited by 55 · cited 1×
“Overall, although the debate whether native protein structure is maintained in the gas phase continues, the future is bright for structural MS analysis of proteins and their complexes, as illustrated by a growing body of work of, for instance, protein–lipid [26, 74, 75], protein–RNA [76], protein– 8 A.”
BackgroundAcquiring Structural Information on Virus Particles with Charge Detection Mass Spectrometry
Keifer, D. Z., Motwani, T., Teschke, C. M., & Jarrold, M. F. (2016) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1362-8 · Cited by 55 · cited 1×
“Being able to monitor both charge and m/z of single ions, CDMS provides significant advances over Q-ToF and Orbitrap mass analyzers alone, whereby at the current stages of development the charge state of complexes over several hundred kDa in size are too heterogeneous to decipher [59].”
BackgroundProtein–Glycosphingolipid Interactions Revealed Using Catch-and-Release Mass Spectrometry
Zhang, Y., Liu, L., Daneshfar, R., Kitova, E. N., Li, C., Jia, F., Cairo, C. W., & Klassen, J. S. (2012) · Analytical Chemistry · doi:10.1021/ac3023857 · Cited by 54 · cited 1×
“Overall, although the debate whether native protein structure is maintained in the gas phase continues, the future is bright for structural MS analysis of proteins and their complexes, as illustrated by a growing body of work of, for instance, protein–lipid [26, 74, 75], protein–RNA [76], protein– 8 A.”
BackgroundChen, F., Gerber, S., Heuser, K., Korkhov, V. M., Lizak, C., Mireku, S. A., Locher, K. P., & Zenobi, R. (2013) · Analytical Chemistry · doi:10.1021/ac4000943 · Cited by 41 · cited 1×
“In addition, the singly charged ions formed can have highm/z values that span beyond the range of most mass analyzers, notwithstanding notable exceptions [32, 33].”
BackgroundLössl, P., Brunner, A. M., Liu, F., Leney, A. C., Yamashita, M., Scheltema, R. A., & Heck, A. J. R. (2016) · ACS Central Science · doi:10.1021/acscentsci.6b00053 · Cited by 36
Self-citationPicodiscs for Facile Protein-Glycolipid Interaction Analysis
Leney, A. C., Darestani, R. R., Li, J., Nikjah, S., Kitova, E. N., Zou, C., Cairo, C. W., Xiong, Z. J., Privé, G. G., & Klassen, J. S. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00170 · Cited by 32 · cited 1×
“Overall, although the debate whether native protein structure is maintained in the gas phase continues, the future is bright for structural MS analysis of proteins and their complexes, as illustrated by a growing body of work of, for instance, protein–lipid [26, 74, 75], protein–RNA [76], protein– 8 A.”
BackgroundSelf-citationAn extended mass range quadrupole for electrospray mass spectrometry
Collings, B. A., & Douglas, D. J. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(96)04478-3 · Cited by 32 · cited 1×
“This m/z range was subsequently increased by the introduction of quadrupoles that operated at a lower radiofrequency [36, 37]; however, the high m/z range was compromised by a lower resolving power.”
BackgroundCoelho, E. D., Arrais, J. P., & Oliveira, J. L. (2013) · Current Topics in Medicinal Chemistry · doi:10.2174/1568026611313050005 · Cited by 32
Plath, L. D., Özdemir, A., Aksenov, A. A., & Bier, M. E. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02180 · Cited by 31 · cited 1×
“In addition, the singly charged ions formed can have highm/z values that span beyond the range of most mass analyzers, notwithstanding notable exceptions [32, 33].”
Backgroundvan de Waterbeemd, M., Lössl, P., Gautier, V., Marino, F., Yamashita, M., Conti, E., Scholten, A., & Heck, A. J. R. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201404637 · Cited by 27 · cited 1×
“This increased resolving power has enabled small differences in proteoforms, such as glycosylation on antibodies [53, 54] and phosphorylation on proteins and protein complexes [55, 56], to be more readily resolved.”
BackgroundSelf-citationAssembling the pieces of macromolecular complexes: Hybrid structural biology approaches
Politis, A., & Borysik, A. J. (2015) · PROTEOMICS · doi:10.1002/pmic.201400507 · Cited by 23 · cited 1×
“The future of structural biology is hybrid [87, 88], indicating that the ideal studies on protein structure combine data of electron microscopy, X-ray crystallography, NMR spectroscopy, and other methods.”
BackgroundWeighing the evidence for structure: electrospray ionization mass spectrometry of proteins
Robinson, C. V., & Radford, S. E. (1995) · Structure · doi:10.1016/s0969-2126(01)00221-0 · Cited by 22
Studies of Noncovalent Complexes in an Electrospray Ionization/ Time-of-Flight Mass Spectrometer
Krutchinsky, A. N., Ayed, A., Donald, L. J., Ens, W., Duckworth, H. W., & Standing, K. G. (2003) · Humana Press eBooks · doi:10.1385/1-59259-045-4:239 · Cited by 22
Scarff, C. A., Ashcroft, A. E., & Radford, S. E. (2015) · Methods in molecular biology · doi:10.1007/978-1-4939-2978-8_8 · Cited by 14
Research works printed but not linked: 2
- Bonifacino JS, 2016, Current protocols in cell biology
- Yang Y, 2016, Nat. Commun.
Cited by
Gehringer, M., & Laufer, S. A. (2019) · Journal of Medicinal Chemistry · doi:10.1021/acs.jmedchem.8b01153 · Cited by 714
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Self-citationAmbient Ionization Mass Spectrometry: Recent Developments and Applications
Feider, C. L., Krieger, A., DeHoog, R. J., & Eberlin, L. S. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b00807 · Cited by 496
Best practices and benchmarks for intact protein analysis for top-down mass spectrometry
Donnelly, D. P., Rawlins, C. M., DeHart, C. J., Fornelli, L., Schachner, L. F., Lin, Z., Lippens, J. L., Aluri, K. C., Sarin, R., Chen, B., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0457-0 · Cited by 377
Ultraviolet Photodissociation Mass Spectrometry for Analysis of Biological Molecules
Brodbelt, J. S., Morrison, L. J., & Santos, I. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00440 · Cited by 295
Metadata
- Authors
- Leney, A. C., & Heck, A. J. R.
- Affiliations
- Utrecht University (NL)
- Corresponding author
- Heck, Albert J. R.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-12-01
- Volume
- 28
- Issue
- 1
- Pages
- 5-13
- ISSN
- 1044-0305 (ISSN-L)
- PMC
- PMC5174146
- OpenAlex
- W2558396410
- Cited by
- 602
- References
- 89
- Citations by year
- 2026: 47 · 2025: 53 · 2024: 60 · 2023: 49 · 2022: 64 · 2021: 87 · 2020: 90 · 2019: 72 · 2018: 52 · 2017: 27
- FWCI
- 25.19
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Journal of the American Society for Mass Spectrometry (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Utrecht University Repository (Utrecht University) (submittedVersion, other-oa)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion, cc-by)
- Funders
- Utrecht University
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- native mass spectrometry, electrospray ionization mass spectrometry, protein-protein complex, protein-ligand complex, protein assembly, quaternary structure, structural biology, structure-function relationship
- MeSH terms
- Animals, DNA, Humans, Models, Molecular, Protein Conformation, Proteins, Spectrometry, Mass, Electrospray Ionization, Protein Multimerization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.