CoChat

Modeling of frost accretion on microchannel evaporators for household refrigerators

Boeng, Joel, de Araujo, Tarik E.H.R.P., Machado, Matheus W., Stahelin, Rodrigues · 2026 · Applied Thermal Engineering

The DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.

Abstract

Frost accretion remains one of the primary factors limiting the thermal performance and energy efficiency of refrigeration systems, as it progressively increases air-side thermal resistance and flow blockage in evaporators. Therefore, the accurate prediction of frost growth and densification is crucial for the design and optimization of high-efficiency evaporators operating under realistic frosted conditions. This study presents a comprehensive mathematical model capable of predicting the thermo-hydraulic behavior of fan-assisted microchannel evaporators for household refrigerators under wet operating conditions. The model builds upon a previously developed frost growth and densification formulation for parallel-plate channels and extends its applicability to compact microchannel geometries. Model predictions were validated against an in-house experimental database, with deviations within ±15% for key performance parameters. The results reveal a trade-off between the external heat transfer area and the resulting evaporation temperature, leading to the existence of an optimal fin density that mitigates the adverse effects of frost accretion while preserving system performance. These findings provide valuable guidelines for the design and optimization of compact evaporators in frost-prone applications.

Overview

Integrity signals

Registry

Crossref · 10.1016/j.applthermaleng.2026.131390

Cites

81 of 81 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Research works printed but not linked: 5

  1. Brian, 1969, Cryogenic frost properties, Cryog. Technol., 5, 205
  2. Tao, 1993, Characteristics of frost growth on a flat plate during the early growth period, ASHRAE Trans., 93, 746
  3. Mao, 1992, Measurement and correlations of frost properties with airflow over a flat plate, ASHRAE Trans., 98, 65
  4. Caetano, 2019, Further development and experimental testing of a resistive sensor for monitoring frost formation in refrigeration systems, Refrig. Sci. Technol., 2191
  5. Kondepudi, 1987, The effect of frost growth on extended surface heat exchanger performance: a review, ASHRAE Trans., 93, 258

Metadata

Authors
Boeng, J., de Araujo, T. E. H. R. P., Machado, M. W., & Stahelin, R.
Affiliations
  • Universidade Federal de Santa Catarina (BR)
  • Whirlpool (Brazil) (BR)
Corresponding author
Boeng, Joel
Venue
Applied Thermal Engineering
Publisher
Elsevier BV
Published
2026-07
Volume
300
Pages
131390
ISSN
1359-4311 (ISSN-L)
OpenAlex
W7160774252
Cited by
3
References
80
Citations by year
2026: 3
FWCI
4.04
Type
journal article
Language
en
Open access
closed
Locations
Applied Thermal Engineering (publishedVersion)
Funders
  • Empresa Brasileira de Pesquisa e Inovação Industrial (PPOL-1911.0022)
  • Conselho Nacional de Desenvolvimento Científico e Tecnológico (404023/2019\u20133)
  • Universidade Federal de Santa Catarina
  • Whirlpool Corporation
  • Fundação de Amparo à Pesquisa e Inovação do Estado de Santa Catarina (2019TR0846)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Boiling Studies
Keywords
microchannel evaporator, household refrigerators, evaporation temperature, thermal-hydraulic modeling

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.