The unit of time: Present and future directions
Open accessThe DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.
Abstract
Some 50 years ago, physicists, and after them the entire world, started to found their time reference on atomic properties instead of motions of the Earth that have been in use since the origin. Far from being an arrival point, this decision marked the beginning of an adventure characterized by an improvement by 6 orders of magnitude in the uncertainty of realization of atomic frequency and time references. Ever-progressing atomic frequency standards and time references derived from them are key resources for science and for society. We will describe how the unit of time is realized with a fractional accuracy approaching 10 − 16 and how it is delivered to users via the elaboration of the international atomic time. We will describe the tremendous progress of optical frequency metrology over the last 20 years that led to a novel generation of optical frequency standards with fractional uncertainties of 10 − 18 . We will describe work toward a possible redefinition of the SI second based on such standards. We will describe existing and emerging applications of atomic frequency standards in science.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045 · cited 2×
“[108] C.”
Quantum dynamics of single trapped ions
Leibfried, D., Blatt, R., Monroe, C., & Wineland, D. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.281 · Cited by 2,739 · cited 1×
“It is nevertheless necessary to care about effects of micro-motions induced by the oscillating electric field [83][84].”
BackgroundQuantum internet: a vision for the road ahead
Wehner, S., Elkouss, D., & Hanson, R. (2018) · Science · doi:10.1126/science.aam9288 · Cited by 2,467
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385 · cited 1×
“A recent and more complete account on optical frequency standards can be found in [81].”
BackgroundFrequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450 · cited 1×
“optical frequency ratios (8 measurements of 5 ratios). Such measurements are not limited by 133Cs fountain. The best measurements so far have a fractional frequency uncertainties near 5 parts in 1017 [173][174]. Among optical-to-optical frequency ratios, only the 199Hg/87Sr is measured independently in at least two la…”
BackgroundSpin squeezing and reduced quantum noise in spectroscopy
Wineland, D. J., Bollinger, J. J., Itano, W. M., Moore, F. L., & Heinzen, D. J. (1992) · Physical Review A · doi:10.1103/physreva.46.r6797 · Cited by 1,135 · cited 1×
“Quantum non-destructive measurements performed on such samples can generate entangled states [114] which are metrologically useful like, for example, spin-squeezed states [115].”
BackgroundAn optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073 · cited 3×
“[66] B.”
BackgroundModern Tests of Lorentz Invariance
Mattingly, D. (2005) · Living Reviews in Relativity · doi:10.12942/lrr-2005-5 · Cited by 1,061
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780 · cited 2×
“possible uncertainties. Figure 4 explains the principle of operation of these two types of standards. Optical frequency standards achieve fractional frequency uncertainties close to 10−18 [61][62][63][64][65][66][67][68]. For example, reference [61] reports an uncertainty of 1.4 ×10−18 for an 171Yb optical lattice sta…”
BackgroundInfluentialAtomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727 · cited 3×
“For example, reference [61] reports an uncertainty of 1.”
BackgroundMethodSingle-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677 · cited 1×
“est possible uncertainties. Figure 4 explains the principle of operation of these two types of standards. Optical frequency standards achieve fractional frequency uncertainties close to 10−18 [61][62][63][64][65][66][67][68]. For example, reference [61] reports an uncertainty of 1.4 ×10−18 for an 171Yb optical lattice…”
BackgroundInfluentialSpectroscopy Using Quantum Logic
Schmidt, P. O., Rosenband, T., Langer, C., Itano, W. M., Bergquist, J. C., & Wineland, D. J. (2005) · Science · doi:10.1126/science.1114375 · Cited by 643 · cited 1×
“Operation of the single Al ion frequency standard relies on a quantum gate between Al and a companion ion used for state readout [77][109][110].”
BackgroundCryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
A 920-Kilometer Optical Fiber Link for Frequency Metrology at the 19th Decimal Place
Predehl, K., Grosche, G., Raupach, S. M. F., Droste, S., Terra, O., Alnis, J., Legero, T., Hänsch, T. W., Udem, T., Holzwarth, R., et al. (2012) · Science · doi:10.1126/science.1218442 · Cited by 543
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495 · cited 1×
“Recently, one of these devices was used for another proofof-concept experiment [195] again in conjunction with coherent optical fiber link.”
MethodA clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460 · cited 4×
“om any place of interest on Earth. First proof-of-concept experiments used coherent optical fiber links between laboratories with already existing state-of-the-art optical frequency metrology programs [137][62]. Over the years, transportable optical frequency standards were developed and currently achieve uncertainties…”
BackgroundMethodInfluentialUltrastable optical clock with two cold-atom ensembles
Schioppo, M., Brown, R. C., McGrew, W. F., Hinkley, N., Fasano, R. J., Beloy, K., Yoon, T. H., Milani, G., Nicolodi, D., Sherman, J. A., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.231 · Cited by 385
A Fermi-degenerate three-dimensional optical lattice clock
Campbell, S. L., Hutson, R. B., Marti, G. E., Goban, A., Darkwah Oppong, N., McNally, R. L., Sonderhouse, L., Robinson, J. M., Zhang, W., Bloom, B. J., et al. (2017) · Science · doi:10.1126/science.aam5538 · Cited by 384 · cited 1×
“Some notable ones are frequency shifts due to blackbody radiation [69][70][64][66][65][67][68][71] and to electric fields [72], shifts induced by the lattice light [73][74], shifts induced by interactions [75], light-shifts induced by probe light [76].”
BackgroundMICROSCOPE Mission: First Results of a Space Test of the Equivalence Principle
Touboul, P., Métris, G., Rodrigues, M., André, Y., Baghi, Q., Bergé, J., Boulanger, D., Bremer, S., Carle, P., Chhun, R., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.119.231101 · Cited by 380
Search for Variations of Fundamental Constants using Atomic Fountain Clocks
Marion, H., Pereira Dos Santos, F., Abgrall, M., Zhang, S., Sortais, Y., Bize, S., Maksimovic, I., Calonico, D., Grünert, J., Mandache, C., et al. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.150801 · Cited by 298 · cited 1×
“redefinition of the second. In 2004, International Committee for Weights and Measures (CIPM) adopted the first SRS, the 87Rb hyperfine frequency based on developments and measurements made at LNE-SYRTE [168][169]. To date, the list of SRS comprises 9 transitions, 8 of which are optical transitions [50]. SRS are atomic tr…”
MethodSelf-citation8 × 10^−17 fractional laser frequency instability with a long room-temperature cavity
Häfner, S., Falke, S., Grebing, C., Vogt, S., Legero, T., Merimaa, M., Lisdat, C., & Sterr, U. (2015) · Optics Letters · doi:10.1364/ol.40.002112 · Cited by 286
The CIPM list of recommended frequency standard values: guidelines and procedures
Riehle, F., Gill, P., Arias, F., & Robertsson, L. (2018) · Metrologia · doi:10.1088/1681-7575/aaa302 · Cited by 281
Riehle, F. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.235 · Cited by 264 · cited 1×
“It remains a topic of investigation to define novel architectures and infrastructures that can take full benefit of the 2 orders of magnitude improved characteristics of optical frequency standards [178].”
BackgroundMehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263 · cited 1×
“Some possibilities are discussed in [188][189][190][191].”
Search for Ultralight Scalar Dark Matter with Atomic Spectroscopy
Van Tilburg, K., Leefer, N., Bougas, L., & Budker, D. (2015) · Physical Review Letters · doi:10.1103/physrevlett.115.011802 · Cited by 253 · cited 2×
“They provide experimental inputs to the quest for a unified theory of gravitation and quantum mechanics [9][10][11] and to the search for dark matter [12][13] and to other applications.”
BackgroundExperimental realization of an optical second with strontium lattice clocks
Le Targat, R., Lorini, L., Le Coq, Y., Zawada, M., Guéna, J., Abgrall, M., Gurov, M., Rosenbusch, P., Rovera, D. G., Nagórny, B., et al. (2013) · Nature Communications · doi:10.1038/ncomms3109 · Cited by 250
Self-citationTransportable Optical Lattice Clock with 7 × 10 − 17 Uncertainty
Koller, S. B., Grotti, J., Vogt, S., Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.073601 · Cited by 238 · cited 1×
“g state-of-the-art optical frequency metrology programs [137][62]. Over the years, transportable optical frequency standards were developed and currently achieve uncertainties in the 10−17 range [192][193][194], also with the aim to increase technology readiness for space. Recently, one of these devices was used for a…”
MethodTest of Special Relativity Using a Fiber Network of Optical Clocks
Delva, P., Lodewyck, J., Bilicki, S., Bookjans, E., Vallet, G., Le Targat, R., Pottie, P.-E., Guerlin, C., Meynadier, F., Le Poncin-Lafitte, C., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.221102 · Cited by 227
Frequency ratio of Yb and Sr clocks with 5 × 10−17 uncertainty at 150 seconds averaging time
Nemitz, N., Ohkubo, T., Takamoto, M., Ushijima, I., Das, M., Ohmae, N., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.20 · Cited by 221
Gravitational Redshift Test Using Eccentric Galileo Satellites
Delva, P., Puchades, N., Schönemann, E., Dilssner, F., Courde, C., Bertone, S., Gonzalez, F., Hees, A., Le Poncin-Lafitte, C., Meynadier, F., et al. (2018) · Physical Review Letters · doi:10.1103/physrevlett.121.231101 · Cited by 210 · cited 1×
“New possibilities are frequently emerging, like for instance, use of fiber links [153] for special relativity tests, of GALILEO satellites for gravitational redshift test [161].”
BackgroundFirst accuracy evaluation of NIST-F2
Heavner, T. P., Donley, E. A., Levi, F., Costanzo, G., Parker, T. E., Shirley, J. H., Ashby, N., Barlow, S., & Jefferts, S. R. (2014) · Metrologia · doi:10.1088/0026-1394/51/3/174 · Cited by 205 · cited 1×
“Implementation of fountains with cryogenic interrogation environment enabled a new direct measurement of effects of thermal radiation shift (“blackbody radiation shift”) [34][35][36][37].”
BackgroundUltra-stable long distance optical frequency distribution using the Internet fiber network
Lopez, O., Haboucha, A., Chanteau, B., Chardonnet, C., Amy-Klein, A., & Santarelli, G. (2012) · Optics Express · doi:10.1364/oe.20.023518 · Cited by 175
Simultaneous remote transfer of accurate timing and optical frequency over a public fiber network
Lopez, O., Kanj, A., Pottie, P.-E., Rovera, D., Achkar, J., Chardonnet, C., Amy-Klein, A., & Santarelli, G. (2013) · Applied Physics B · doi:10.1007/s00340-012-5241-0 · Cited by 168 · cited 1×
“Besides frequency transfer using a coherent optical carrier, time transfer using optical fibers is actively developed with, here also, the promise to surpass existing methods by orders of magnitude (see, for instance [145][146][147][148]).”
Theoretical aspects of the equivalence principle
Damour, T. (2012) · Classical and Quantum Gravity · doi:10.1088/0264-9381/29/18/184001 · Cited by 164 · cited 1×
“For these reasons, they are good tools for revealing physics beyond general relativity and the standard model and for providing experimental constraints to guide the development of unified theories (see for instance [156][157][158]).”
BackgroundFrequency comparison of optical lattice clocks beyond the Dick limit
Takamoto, M., Takano, T., & Katori, H. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.34 · Cited by 154
Realization of a timescale with an accurate optical lattice clock
Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C. (2016) · Optica · doi:10.1364/optica.3.000563 · Cited by 149
Origlia, S., Pramod, M. S., Schiller, S., Singh, Y., Bongs, K., Schwarz, R., Al-Masoudi, A., Dörscher, S., Herbers, S., Häfner, S., et al. (2018) · Physical Review A · doi:10.1103/physreva.98.053443 · Cited by 142
Atomic Clock with 1 × 10 − 18 Room-Temperature Blackbody Stark Uncertainty
Beloy, K., Hinkley, N., Phillips, N. B., Sherman, J. A., Schioppo, M., Lehman, J., Feldman, A., Hanssen, L. M., Oates, C. W., & Ludlow, A. D. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.260801 · Cited by 137 · cited 2×
“71Yb+ ion standard. Many physical effects had to be understood and controlled at an even lower level individually. Some notable ones are frequency shifts due to blackbody radiation [69][70][64][66][65][67][68][71] and to electric fields [72], shifts induced by the lattice light [73][74], shifts induced by interactions […”
BackgroundInfluentialExperimental constraint on dark matter detection with optical atomic clocks
Wcisło, P., Morzyński, P., Bober, M., Cygan, A., Lisak, D., Ciuryło, R., & Zawada, M. (2016) · Nature Astronomy · doi:10.1038/s41550-016-0009 · Cited by 116 · cited 1×
“Searches for dark matter with frequency standards are reported in [12][13][160].”
BackgroundOptical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Lodewyck, J., Bilicki, S., Bookjans, E., Robyr, J.-L., Shi, C., Vallet, G., Le Targat, R., Nicolodi, D., Le Coq, Y., Guéna, J., et al. (2016) · Metrologia · doi:10.1088/0026-1394/53/4/1123 · Cited by 102 · cited 3×
“Reliable optical frequency comb systems can deal with multiple wavelengths simultaneously and support complex optical and microwave frequency standard comparisons and microwave generation applied to atomic fountains [131][132][133][134][135][136][45][137][138].”
BackgroundSelf-citationHyperpolarizability and Operational Magic Wavelength in an Optical Lattice Clock
Brown, R. C., Phillips, N. B., Beloy, K., McGrew, W. F., Schioppo, M., Fasano, R. J., Milani, G., Zhang, X., Hinkley, N., Leopardi, H., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.119.253001 · Cited by 101 · cited 1×
“Some notable ones are frequency shifts due to blackbody radiation [69][70][64][66][65][67][68][71] and to electric fields [72], shifts induced by the lattice light [73][74], shifts induced by interactions [75], light-shifts induced by probe light [76].”
BackgroundDenker, H., Timmen, L., Voigt, C., Weyers, S., Peik, E., Margolis, H. S., Delva, P., Wolf, P., & Petit, G. (2018) · Journal of Geodesy · doi:10.1007/s00190-017-1075-1 · Cited by 91
Comparing a mercury optical lattice clock with microwave and optical frequency standards
Tyumenev, R., Favier, M., Bilicki, S., Bookjans, E., Targat, R. L., Lodewyck, J., Nicolodi, D., Coq, Y. L., Abgrall, M., Guéna, J., et al. (2016) · New Journal of Physics · doi:10.1088/1367-2630/18/11/113002 · Cited by 85
Self-citationNoise and instability of an optical lattice clock
Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2015) · Physical Review A · doi:10.1103/physreva.92.063814 · Cited by 84 · cited 1×
“Evaluation of uncertainties and comparisons at the 10 level are made possible by the excellent short term stabilities reached by optical frequency standards [88][89][90][91][92].”
BackgroundGuéna, J., Weyers, S., Abgrall, M., Grebing, C., Gerginov, V, Rosenbusch, P., Bize, S., Lipphardt, B., Denker, H., Quintin, N., et al. (2017) · Metrologia · doi:10.1088/1681-7575/aa65fe · Cited by 83 · cited 3×
“Reliable optical frequency comb systems can deal with multiple wavelengths simultaneously and support complex optical and microwave frequency standard comparisons and microwave generation applied to atomic fountains [131][132][133][134][135][136][45][137][138].”
BackgroundSelf-citationMonths-long real-time generation of a time scale based on an optical clock
Hachisu, H., Nakagawa, F., Hanado, Y., & Ido, T. (2018) · Scientific Reports · doi:10.1038/s41598-018-22423-5 · Cited by 83 · cited 1×
“Reliable operation and use of (87)Sr optical lattice standards to this end is described in [136][176].”
Bondarescu, R., Bondarescu, M., Hetényi, G., Boschi, L., Jetzer, P., & Balakrishna, J. (2012) · Geophysical Journal International · doi:10.1111/j.1365-246x.2012.05636.x · Cited by 71
Determination of a high spatial resolution geopotential model using atomic clock comparisons
Lion, G., Panet, I., Wolf, P., Guerlin, C., Bize, S., & Delva, P. (2017) · Journal of Geodesy · doi:10.1007/s00190-016-0986-6 · Cited by 66 · cited 1×
“Reference [187] reports one of the first quantitative studies along this line.”
BackgroundFrequency and time transfer for metrology and beyond using telecommunication network fibres
Lopez, O., Kéfélian, F., Jiang, H., Haboucha, A., Bercy, A., Stefani, F., Chanteau, B., Kanj, A., Rovera, D., Achkar, J., et al. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.04.005 · Cited by 61
The relativistic redshift with 3 10 17uncertainty at NIST, Boulder, Colorado, USA
Pavlis, N. K., & Weiss, M. A. (2003) · Metrologia · doi:10.1088/0026-1394/40/2/311 · Cited by 57
Ground-based optical atomic clocks as a tool to monitor vertical surface motion
Bondarescu, R., Schärer, A., Lundgren, A., Hetényi, G., Houlié, N., Jetzer, P., & Bondarescu, M. (2015) · Geophysical Journal International · doi:10.1093/gji/ggv246 · Cited by 56 · cited 1×
“Some possibilities are discussed in [188][189][190][191].”
Hachisu, H., Petit, G., Nakagawa, F., Hanado, Y., & Ido, T. (2017) · Optics Express · doi:10.1364/oe.25.008511 · Cited by 53
Direct comparison of optical lattice clocks with an intercontinental baseline of 9000 km
Hachisu, H., Fujieda, M., Nagano, S., Gotoh, T., Nogami, A., Ido, T., Falke, S., Huntemann, N., Grebing, C., Lipphardt, B., et al. (2014) · Optics Letters · doi:10.1364/ol.39.004072 · Cited by 53
Voigt, C., Denker, H., & Timmen, L. (2016) · Metrologia · doi:10.1088/0026-1394/53/6/1365 · Cited by 50
Relativistic corrections for time and frequency transfer in optical fibres
Geršl, J., Delva, P., & Wolf, P. (2015) · Metrologia · doi:10.1088/0026-1394/52/4/552 · Cited by 40 · cited 1×
“Relativistic effects in optical fiber links are studied from a theoretical standpoint in [149].”
BackgroundMargolis, H. S., & Gill, P. (2015) · Metrologia · doi:10.1088/0026-1394/52/5/628 · Cited by 40 · cited 1×
“Values are determined based on the least-square adjustments to high accuracy measurements found in peer-reviewed publications [170][171][50].”
MethodChronometric Geodesy: Methods and Applications
Delva, P., Denker, H., & Lion, G. (2019) · Fundamental Theories of Physics · doi:10.1007/978-3-030-11500-5_2 · Cited by 28 · cited 1×
“as sensors to determine gravitational potential differences for the purpose of geodesy 14 and Earth’s science. This method called chronometric geodesy was proposed several decades ago (see for example [180] and references therein). However, it is only now that progress in optical frequency standards and in optical freq…”
MethodGravitational redshift at INRIM
Calonico, D., Cina, A., Bendea, I. H., Levi, F., Lorini, L., & Godone, A. (2007) · Metrologia · doi:10.1088/0026-1394/44/5/n03 · Cited by 22
Cited by
Long term measurement of theSr87clock frequency at the limit of primary Cs clocks
Schwarz, R., Dörscher, S., Al-Masoudi, A., Benkler, E., Legero, T., Sterr, U., Weyers, S., Rahm, J., Lipphardt, B., & Lisdat, C. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.033242 · Cited by 64
Real-time phase tracking for wide-band optical frequency measurements at the 20th decimal place
Giunta, M., Hänsel, W., Fischer, M., Lezius, M., Udem, T., & Holzwarth, R. (2020) · Nature Photonics · doi:10.1038/s41566-019-0520-5 · Cited by 41
A perspective on the future of transportable optical lattice clocks
Takamoto, M., Tanaka, Y., & Katori, H. (2022) · Applied Physics Letters · doi:10.1063/5.0087894 · Cited by 40
Direct comparisons of European primary and secondary frequency standards via satellite techniques
Riedel, F., Al-Masoudi, A., Benkler, E., Dörscher, S., Gerginov, V, Grebing, C., Häfner, S., Huntemann, N., Lipphardt, B., Lisdat, C., et al. (2020) · Metrologia · doi:10.1088/1681-7575/ab6745 · Cited by 38
Self-citationFundamental constants: from measurement to the universe, a window on gravitation and cosmology
Uzan, J.-P. (2025) · Living Reviews in Relativity · doi:10.1007/s41114-025-00059-y · Cited by 36
Metadata
- Authors
- Bize, S.
- Venue
- Comptes Rendus. Physique
- Publisher
- MathDoc/Centre Mersenne
- Published
- 2019-01-01
- Volume
- 20
- Issue
- 1-2
- Pages
- 153-168
- ISSN
- 1631-0705 (ISSN-L)
- 1878-1535
- OpenAlex
- W2917496704
- Cited by
- 47
- References
- 60
- FWCI
- 3.00
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.