A practical guide to the development of microneedle systems – In clinical trials or on the market
The DOI matches its Crossref record; 102 of the 102 references it cites were found in a registry or an index.
Abstract
Microneedle systems are a rapidly growing and promising technology for delivery of drugs, such as vaccines, small molecules, or biologics and for aesthetic skin treatment in local clinics; however, they remain relatively new from a regulatory perspective. There are strong demands for established procedures, test requirements for approval, and recent trends that industries/researchers related to microneedle systems can refer to. Some microneedle systems are commercially available, many are currently undergoing clinical trials, and some are pending approval for commercialization. This review focuses on microneedle systems that are either on the market or in clinical trials, their applicability and characteristics, and the critical evaluation and test methods necessary for their development and approval.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dendritic cells and the control of immunity
Banchereau, J., & Steinman, R. M. (1998) · Nature · doi:10.1038/32588 · Cited by 14,336
Microneedles for drug and vaccine delivery
Kim, Y.-C., Park, J.-H., & Prausnitz, M. R. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.04.005 · Cited by 1,760
Microfabricated Microneedles: A Novel Approach to Transdermal Drug Delivery
Henry, S., McAllister, D. V., Allen, M. G., & Prausnitz, M. R. (1998) · Journal of Pharmaceutical Sciences · doi:10.1021/js980042+ · Cited by 1,346
Larrañeta, E., Lutton, R. E. M., Woolfson, A. D., & Donnelly, R. F. (2016) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2016.03.001 · Cited by 964
Davis, S. P., Landis, B. J., Adams, Z. H., Allen, M. G., & Prausnitz, M. R. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.010 · Cited by 934
Origin, homeostasis and function of Langerhans cells and other langerin-expressing dendritic cells
Merad, M., Ginhoux, F., & Collin, M. (2008) · Nature Reviews Immunology · doi:10.1038/nri2455 · Cited by 850
Yu, J., Zhang, Y., Ye, Y., DiSanto, R., Sun, W., Ranson, D., Ligler, F. S., Buse, J. B., & Gu, Z. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1505405112 · Cited by 848
Force Modeling for Needle Insertion Into Soft Tissue
Okamura, A. M., Simone, C., & O'Leary, M. D. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.831542 · Cited by 830
Enhanced Cancer Immunotherapy by Microneedle Patch-Assisted Delivery of Anti-PD1 Antibody
Wang, C., Ye, Y., Hochu, G. M., Sadeghifar, H., & Gu, Z. (2016) · Nano Letters · doi:10.1021/acs.nanolett.5b05030 · Cited by 784
Hydrogel‐Forming Microneedle Arrays for Enhanced Transdermal Drug Delivery
Donnelly, R. F., Singh, T. R. R., Garland, M. J., Migalska, K., Majithiya, R., McCrudden, C. M., Kole, P. L., Mahmood, T. M. T., McCarthy, H. O., & Woolfson, A. D. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201200864 · Cited by 727
Microneedle-based drug delivery systems: Microfabrication, drug delivery, and safety
Donnelly, R. F., Singh, T. R. R., & Woolfson, A. D. (2010) · Drug Delivery · doi:10.3109/10717541003667798 · Cited by 708
Recent advances in biosensor development for the detection of cancer biomarkers
Jayanthi, V. S. P. K. S. A., Das, A. B., & Saxena, U. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.12.014 · Cited by 565
Transdermal Delivery of Drugs with Microneedles—Potential and Challenges
Ita, K. (2015) · Pharmaceutics · doi:10.3390/pharmaceutics7030090 · Cited by 530
Rouphael, N. G., Paine, M., Mosley, R., Henry, S., McAllister, D. V., Kalluri, H., Pewin, W., Frew, P. M., Yu, T., Thornburg, N. J., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30575-5 · Cited by 442
Engineering Microneedle Patches for Vaccination and Drug Delivery to Skin
Prausnitz, M. R. (2017) · Annual Review of Chemical and Biomolecular Engineering · doi:10.1146/annurev-chembioeng-060816-101514 · Cited by 439
Electrical properties of the epidermal stratum corneum
Yamamoto, T., & Yamamoto, Y. (1976) · Medical & Biological Engineering · doi:10.1007/bf02478741 · Cited by 436
Subcutaneous Incisionless (Subcision) Surgery for the Correction of Depressed Scars and Wrinkles
ORENTREICH, D. S., & ORENTREICH, N. (1995) · Dermatologic Surgery · doi:10.1111/j.1524-4725.1995.tb00259.x · Cited by 424
Donnelly, R. F., Majithiya, R., Singh, T. R. R., Morrow, D. I. J., Garland, M. J., Demir, Y. K., Migalska, K., Ryan, E., Gillen, D., Scott, C. J., et al. (2011) · Pharmaceutical Research · doi:10.1007/s11095-010-0169-8 · Cited by 417
A Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring
Cengiz, E., & Tamborlane, W. V. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0002 · Cited by 390
Donnelly, R. F., McCrudden, M., Alkilani, A. Z., Larrañeta, E., McAlister, E., Courtenay, A. J., Kearney, M., Singh, T. R. R., McCarthy, H. O., Kett, V. L., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0111547 · Cited by 370
Mechanisms of sampling interstitial fluid from skin using a microneedle patch
Samant, P. P., & Prausnitz, M. R. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1716772115 · Cited by 363
Kinetics of skin resealing after insertion of microneedles in human subjects
Gupta, J., Gill, H. S., Andrews, S. N., & Prausnitz, M. R. (2011) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.05.021 · Cited by 342
Coating Formulations for Microneedles
Gill, H. S., & Prausnitz, M. R. (2007) · Pharmaceutical Research · doi:10.1007/s11095-007-9286-4 · Cited by 318
Dissolving Microneedle Patch for Transdermal Delivery of Human Growth Hormone
Lee, J. W., Choi, S., Felner, E. I., & Prausnitz, M. R. (2011) · Small · doi:10.1002/smll.201001091 · Cited by 301
New insulin delivery recommendations
Frid, A. H., Kreugel, G., Grassi, G., Halimi, S., Hicks, D., Hirsch, L. J., Smith, M. J., Wellhoener, R., Bode, B. W., Hirsch, I. B., et al. (2016) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2016.06.010 · Cited by 286
Recent advances in the design of polymeric microneedles for transdermal drug delivery and biosensing
Wang, M., Hu, L., & Xu, C. (2017) · Lab on a Chip · doi:10.1039/c7lc00016b · Cited by 285
Olatunji, O., Das, D. B., Garland, M. J., Belaid, L., & Donnelly, R. F. (2013) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.23439 · Cited by 277
Extraction and biomolecular analysis of dermal interstitial fluid collected with hollow microneedles
Miller, P. R., Taylor, R. M., Tran, B. Q., Boyd, G., Glaros, T., Chavez, V. H., Krishnakumar, R., Sinha, A., Poorey, K., Williams, K. P., et al. (2018) · Communications Biology · doi:10.1038/s42003-018-0170-z · Cited by 258
Physiological Differences Between Interstitial Glucose and Blood Glucose Measured in Human Subjects
Kulcu, E., Tamada, J. A., Reach, G., Potts, R. O., & Lesho, M. J. (2003) · Diabetes Care · doi:10.2337/diacare.26.8.2405 · Cited by 251
Laurent, A., Mistretta, F., Bottigioli, D., Dahel, K., Goujon, C., Nicolas, J. F., Hennino, A., & Laurent, P. E. (2007) · Vaccine · doi:10.1016/j.vaccine.2007.05.046 · Cited by 235
Daddona, P. E., Matriano, J. A., Mandema, J., & Maa, Y.-F. (2011) · Pharmaceutical Research · doi:10.1007/s11095-010-0192-9 · Cited by 234
Krielgaard, L., Jones, L. S., Randolph, T. W., Frokjaer, S., Flink, J. M., Manning, M. C., & Carpenter, J. F. (1998) · Journal of Pharmaceutical Sciences · doi:10.1021/js980126i · Cited by 232
Verbaan, F. J., Bal, S. M., van den Berg, D. J., Groenink, W. H. H., Verpoorten, H., Lüttge, R., & Bouwstra, J. A. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.11.009 · Cited by 227
Microneedle Arrays Allow Lower Microbial Penetration Than Hypodermic Needles In Vitro
Donnelly, R. F., Singh, T. R. R., Tunney, M. M., Morrow, D. I. J., McCarron, P. A., O’Mahony, C., & Woolfson, A. D. (2009) · Pharmaceutical Research · doi:10.1007/s11095-009-9967-2 · Cited by 227
Alhadj Ali, M., Liu, Y.-F., Arif, S., Tatovic, D., Shariff, H., Gibson, V. B., Yusuf, N., Baptista, R., Eichmann, M., Petrov, N., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf7779 · Cited by 212
Minimally Invasive Insulin Delivery in Subjects with Type 1 Diabetes Using Hollow Microneedles
Gupta, J., Felner, E. I., & Prausnitz, M. R. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0103 · Cited by 209
The effects of geometry on skin penetration and failure of polymer microneedles
Gittard, S. D., Chen, B., Xu, H., Ovsianikov, A., Chichkov, B. N., Monteiro-Riviere, N. A., & Narayan, R. J. (2012) · Journal of Adhesion Science and Technology · doi:10.1080/01694243.2012.705101 · Cited by 204
Microneedle Coating Techniques for Transdermal Drug Delivery
Haj‐Ahmad, R., Khan, H., Arshad, M. S., Rasekh, M., Hussain, A., Walsh, S. E., Li, X., Chang, M., & Ahmad, Z. (2015) · Pharmaceutics · doi:10.3390/pharmaceutics7040486 · Cited by 203
Inkjet printing of transdermal microneedles for the delivery of anticancer agents
Uddin, M. J., Scoutaris, N., Klepetsanis, P., Chowdhry, B., Prausnitz, M. R., & Douroumis, D. (2015) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2015.01.038 · Cited by 198
Successful application of large microneedle patches by human volunteers
Ripolin, A., Quinn, J., Larrañeta, E., Vicente-Perez, E. M., Barry, J., & Donnelly, R. F. (2017) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2017.02.011 · Cited by 193
Aussedat, B., Dupire-Angel, M., Gifford, R., Klein, J. C., Wilson, G. S., & Reach, G. (2000) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.2000.278.4.e716 · Cited by 186
Zhang, Y., Brown, K., Siebenaler, K., Determan, A., Dohmeier, D., & Hansen, K. (2012) · Pharmaceutical Research · doi:10.1007/s11095-011-0524-4 · Cited by 185
Ziegler, C., & Göpel, W. (1998) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(98)80087-2 · Cited by 180
Infusion pressure and pain during microneedle injection into skin of human subjects
Gupta, J., Park, S. S., Bondy, B. J., Felner, E. I., & Prausnitz, M. R. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.05.061 · Cited by 180
Effect of Microneedle Geometry and Supporting Substrate on Microneedle Array Penetration into Skin
Kochhar, J. S., Quek, T. C., Soon, W. J., Choi, J., Zou, S., & Kang, L. (2013) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.23724 · Cited by 177
Gowers, S. A. N., Freeman, D. M. E., Rawson, T. M., Rogers, M. L., Wilson, R. C., Holmes, A. H., Cass, A. E., & O’Hare, D. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00288 · Cited by 159
Morales, J. O., Fathe, K. R., Brunaugh, A., Ferrati, S., Li, S., Montenegro-Nicolini, M., Mousavikhamene, Z., McConville, J. T., Prausnitz, M. R., & Smyth, H. D. C. (2017) · The AAPS Journal · doi:10.1208/s12248-017-0054-z · Cited by 154
Proinsulin peptide immunotherapy in type 1 diabetes: report of a first-in-man Phase I safety study
Thrower, S. L., James, L., Hall, W., Green, K. M., Arif, S., Allen, J. S., Van-Krinks, C., Lozanoska-Ochser, B., Marquesini, L., Brown, S., et al. (2009) · Clinical and Experimental Immunology · doi:10.1111/j.1365-2249.2008.03814.x · Cited by 153
Considerations in the sterile manufacture of polymeric microneedle arrays
McCrudden, M., Alkilani, A. Z., Courtenay, A. J., McCrudden, C. M., McCloskey, B., Walker, C., Alshraiedeh, N., Lutton, R. E. M., Gilmore, B., Woolfson, A. D., et al. (2014) · Drug Delivery and Translational Research · doi:10.1007/s13346-014-0211-1 · Cited by 153
Duarah, S., Sharma, M., & Wen, J. (2019) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2019.01.005 · Cited by 149
Effect of Transdermal Teriparatide Administration on Bone Mineral Density in Postmenopausal Women
Cosman, F., Lane, N. E., Bolognese, M. A., Zanchetta, J. R., Garcia-Hernandez, P. A., Sees, K., Matriano, J. A., Gaumer, K., & Daddona, P. E. (2010) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2009-0358 · Cited by 148
Soltani-Arabshahi, R., Wong, J. W., Duffy, K. L., & Powell, D. L. (2014) · JAMA Dermatology · doi:10.1001/jamadermatol.2013.6955 · Cited by 147
Norman, J. J., Brown, M. R., Raviele, N. A., Prausnitz, M. R., & Felner, E. I. (2013) · Pediatric Diabetes · doi:10.1111/pedi.12031 · Cited by 142
Coulman, S. A., Birchall, J. C., Alex, A., Pearton, M., Höfer, B., O’Mahony, C., Drexler, W., & Považay, B. (2010) · Pharmaceutical Research · doi:10.1007/s11095-010-0167-x · Cited by 139
Drug-coated microneedles for rapid and painless local anesthesia
Baek, S.-H., Shin, J.-H., & Kim, Y. (2017) · Biomedical Microdevices · doi:10.1007/s10544-016-0144-1 · Cited by 138
Loizidou, E. Z., Inoue, N. T., Ashton-Barnett, J., Barrow, D. A., & Allender, C. J. (2016) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2016.06.023 · Cited by 135
Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid
Bantle, J. P., & Thomas, W. (1997) · Journal of Laboratory and Clinical Medicine · doi:10.1016/s0022-2143(97)90044-5 · Cited by 128
Vora, L. K., Vavia, P. R., Larrañeta, E., Bell, S. E. J., & Donnelly, R. F. (2018) · Journal of Interdisciplinary Nanomedicine · doi:10.1002/jin2.41 · Cited by 128
A pilot study in humans of microneedle sensor arrays for continuous glucose monitoring
Sharma, S., El-Laboudi, A., Reddy, M., Jugnee, N., Sivasubramaniyam, S., El Sharkawy, M., Georgiou, P., Johnston, D., Oliver, N., & Cass, A. E. G. (2018) · Analytical Methods · doi:10.1039/c8ay00264a · Cited by 123
Suction blister fluid as potential body fluid for biomarker proteins
Kool, J., Reubsaet, L., Wesseldijk, F., Maravilha, R. T., Pinkse, M. W. H., D’Santos, C. S., van Hilten, J. J., Zijlstra, F. J., & Heck, A. J. R. (2007) · PROTEOMICS · doi:10.1002/pmic.200600938 · Cited by 119
Analysis of mechanical failure of polymer microneedles by axial force
Park, J., & Prausnitz, M. R. (2010) · Journal of the Korean Physical Society · doi:10.3938/jkps.56.1223 · Cited by 118
Recruitment and Collection of Dermal Interstitial Fluid Using a Microneedle Patch
Kolluru, C., Williams, M., Chae, J., & Prausnitz, M. R. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801262 · Cited by 117
Sharpening of hollow silicon microneedles to reduce skin penetration force
Khanna, P., Luongo, K., Strom, J. A., & Bhansali, S. (2010) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/20/4/045011 · Cited by 116
The Use of Silicon Microfabrication Technology in Painless Blood Glucose Monitoring
Smart, W. H., & Subramanian, K. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050501961 · Cited by 101
Does fall in tissue glucose precede fall in blood glucose?
Sternberg, F., Meyerhoff, C., Mennel, F. J., Mayer, H. G., Bischof, F., & Pfeiffer, E. F. (1996) · Diabetologia · doi:10.1007/bf00403309 · Cited by 101
Antigen-Specific Immunotherapy for Type 1 Diabetes: Maximizing the Potential
Peakman, M., & von Herrath, M. (2010) · Diabetes · doi:10.2337/db10-0630 · Cited by 98
Microneedle Integrated Transdermal Patch for Fast Onset and Sustained Delivery of Lidocaine
Kochhar, J. S., Lim, W. X. S., Zou, S., Foo, W. Y., Pan, J., & Kang, L. (2013) · Molecular Pharmaceutics · doi:10.1021/mp400359w · Cited by 97
Self-sterilizing antibacterial silver-loaded microneedles
García, L. E. G., MacGregor, M., Visalakshan, R. M., Ninan, N., Cavallaro, A., Trinidad, A. D., Zhao, Y., Hayball, J. D., & Vasilev, K. A. (2019) · Chemical Communications · doi:10.1039/c8cc06035e · Cited by 96
Goldstein, D. A., Do, D., Noronha, G., Kissner, J. M., Srivastava, S. K., & Nguyen, Q. D. (2016) · Translational Vision Science & Technology · doi:10.1167/tvst.5.6.14 · Cited by 91
Intradermal delivery for vaccine dose sparing: Overview of current issues
Zehrung, D., Jarrahian, C., & Wales, A. (2012) · Vaccine · doi:10.1016/j.vaccine.2012.11.021 · Cited by 88
Taş, Ç., Mistilis, J. J., Nguyen, H. X., Eangoor, P., Knaack, J. S., Banga, A. K., & Prausnitz, M. R. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.10.021 · Cited by 88
Ma, Y., & Gill, H. S. (2014) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.24159 · Cited by 87
Müller, A. C., Breitwieser, F. P., Fischer, H., Schuster, C., Brandt, O., Colinge, J., Superti‐Furga, G., Stingl, G., Elbe‐Bürger, A., & Bennett, K. L. (2012) · Journal of Proteome Research · doi:10.1021/pr3002035 · Cited by 86
Diagnostic opportunities based on skin biomarkers
Paliwal, S., Hwang, B. H., Tsai, K. Y., & Mitragotri, S. (2012) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2012.10.009 · Cited by 85
Hydrodynamic gene delivery in human skin using a hollow microneedle device
Dul, M., Stefanidou, M., Porta, P. A., Serve, J., O’Mahony, C., MALISSEN, B., Henri, S., Levin, Y., Kochba, E., Wong, F. S., et al. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.02.028 · Cited by 82
Tumor interstitial fluid — A treasure trove of cancer biomarkers
Gromov, P., Gromova, I., Olsen, C. J., Wielenga, V. T., Talman, M.-L., Serizawa, R., & Moreira, J. M. A. (2013) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2013.01.013 · Cited by 81
Sasaki, G. H. (2016) · Aesthetic Surgery Journal · doi:10.1093/asj/sjw120 · Cited by 79
Spierings, E. L. H., Brandes, J. L., Kudrow, D., Weintraub, J., Schmidt, P. C., Kellerman, D. J., & Tepper, S. J. (2017) · Cephalalgia · doi:10.1177/0333102417737765 · Cited by 73
Kolluru, C., Williams, M., Yeh, J. S., Noel, R. K., Knaack, J. S., & Prausnitz, M. R. (2019) · Biomedical Microdevices · doi:10.1007/s10544-019-0363-3 · Cited by 72
Rapid Local Anesthesia in Humans Using Minimally Invasive Microneedles
Gupta, J., Denson, D. D., Felner, E. I., & Prausnitz, M. R. (2011) · Clinical Journal of Pain · doi:10.1097/ajp.0b013e318225dbe9 · Cited by 72
Dul, M., Nikolić, T., Stefanidou, M., McAteer, M. A., Williams, P. M., Mous, J., Roep, B. O., Kochba, E., Levin, Y., Peakman, M., et al. (2019) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2019.03.041 · Cited by 65
Functionalized microneedles for continuous glucose monitoring
Takeuchi, K., & Kim, B. (2018) · Nano Convergence · doi:10.1186/s40580-018-0161-2 · Cited by 63
Ameri, M., Kadkhodayan, M., Nguyen, J., Bravo, J., Su, R., Chan, K., Samiee, A., & Daddona, P. E. (2014) · Pharmaceutics · doi:10.3390/pharmaceutics6020220 · Cited by 63
Chitin Microneedles for an Easy‐to‐Use Tuberculosis Skin Test
Jin, J., Reese, V. A., Coler, R. N., Carter, D., & Rolandi, M. (2013) · Advanced Healthcare Materials · doi:10.1002/adhm.201300185 · Cited by 63
Portugal‐Cohen, M., Horev, L., Rüffer, C., Schlippe, G., Voss, W., Ma’or, Z., Oron, M., Soroka, Y., Frušić‐Zlotkin, M., Milner, Y., et al. (2012) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2011.12.009 · Cited by 59
Naito, C., Katsumi, H., Suzuki, T., Quan, Y., Kamiyama, F., Sakane, T., & Yamamoto, A. (2018) · Pharmaceutics · doi:10.3390/pharmaceutics10040215 · Cited by 58
Bergenstal, R. M., Strock, E. S., Peremislov, D., Gibney, M. A., Parvu, V., & Hirsch, L. J. (2015) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2014.12.014 · Cited by 54
Profile of Abaloparatide and Its Potential in the Treatment of Postmenopausal Osteoporosis
Tella, S. H., Kommalapati, A., & Correa, R. (2017) · Cureus · doi:10.7759/cureus.1300 · Cited by 54
Fluzone® intra-dermal (Intanza®/Istivac® Intra-dermal): An updated overview
Bragazzi, N. L., Orsi, A., Ansaldi, F., Gasparini, R., & Icardi, G. (2016) · Human Vaccines & Immunotherapeutics · doi:10.1080/21645515.2016.1187343 · Cited by 52
Chiang, B., Wang, K., Ethier, C. R., & Prausnitz, M. R. (2017) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-20679 · Cited by 51
Littauer, E. Q., Mills, L. K., Brock, N., Esser, E. S., Romanyuk, A. V., Pulit-Penaloza, J. A., Vassilieva, E. V., Beaver, J. T., Antao, O. Q., Krammer, F., et al. (2018) · Journal of Controlled Release · doi:10.1016/j.jconrel.2018.02.033 · Cited by 50
Microneedle penetration and injection past the stratum corneum in humans
Sivamani, R. K., Stoeber, B., Liepmann, D., et al. (2008) · Journal of Dermatological Treatment · doi:10.1080/09546630802512679 · Cited by 46
Fluid absorption by skin tissue during intradermal injections through hollow microneedles
Shrestha, P., & Stoeber, B. (2018) · Scientific Reports · doi:10.1038/s41598-018-32026-9 · Cited by 45
Chiang, B., Venugopal, N., Grossniklaus, H. E., Jung, J. H., Edelhauser, H. F., & Prausnitz, M. R. (2017) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.16-20377 · Cited by 41
Lee, H., Kim, D., & Park, C.-W. (2017) · Journal of Pharmaceutical Investigation · doi:10.1007/s40005-017-0359-z · Cited by 41
Self-citationCoyne, J., Davis, B., Kauffman, D., Zhao, N., & Wang, Y. (2017) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.7b00718 · Cited by 37
In Vivo Iontophoretic Delivery of Salmon Calcitonin Across Microporated Skin
Vemulapalli, V., Bai, Y., Kalluri, H., Herwadkar, A., Kim, H., Davis, S. P., Friden, P. M., & Banga, A. K. (2012) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.23222 · Cited by 29
Rapid Systemic Delivery of Zolmitriptan Using an Adhesive Dermally Applied Microarray
Kellerman, D. J., Ameri, M., & Tepper, S. J. (2017) · Pain Management · doi:10.2217/pmt-2017-0036 · Cited by 28
Safety and efficacy of tuberculin skin testing with microneedle MicronJet600™ in healthy adults
Lee, H., Choi, H.-J., Kim, D.-R., Lee, H., Jin, J.-E., Kim, Y.-R., Lee, M. S., Cho, S.-N., & Kang, Y. A. (2016) · The International Journal of Tuberculosis and Lung Disease · doi:10.5588/ijtld.15.0678 · Cited by 11
Self-citationA Pain-free Lancet with a Small Needle for Glucose Measurement
Kim, S. E. (2010) · Clinical Medicine Insights Endocrinology and Diabetes · doi:10.4137/cmed.s3775 · Cited by 11
Recent research trend in cell and drug delivery system for type 1 diabetes treatment
Im, G., & Bhang, S. H. (2018) · Journal of Pharmaceutical Investigation · doi:10.1007/s40005-017-0380-2 · Cited by 8
Ocular delivery systems for the administration of antibody therapeutics
Jin, S., & Hwang, S. (2017) · Journal of Pharmaceutical Investigation · doi:10.1007/s40005-017-0336-6 · Cited by 6
Cited by
Current trends in polymer microneedle for transdermal drug delivery
Ahmed Saeed AL-Japairai, K., Mahmood, S., Hamed Almurisi, S., Reddy Venugopal, J., Rebhi Hilles, A., Azmana, M., & Raman, S. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2020.119673 · Cited by 448
Microneedle-mediated transdermal drug delivery for treating diverse skin diseases
Yang, D., Chen, M., Sun, Y., Jin, Y., Lu, C., Pan, X., Quan, G., & Wu, C. (2021) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.12.004 · Cited by 259
Vaccination into the Dermal Compartment: Techniques, Challenges, and Prospects
Hettinga, J., & Carlisle, R. (2020) · Vaccines · doi:10.3390/vaccines8030534 · Cited by 72
Metadata
- Authors
- Lee, K. J., Jeong, S. S., Roh, D. H., Kim, D. Y., Choi, H.-K., & Lee, E. H.
- Venue
- International Journal of Pharmaceutics
- Publisher
- Elsevier BV
- Published
- 2020-01
- Volume
- 573
- Pages
- 118778
- ISSN
- 0378-5173 (ISSN-L)
- OpenAlex
- W2984747528
- Cited by
- 173
- References
- 102
- FWCI
- 6.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.