The DOI matches its Crossref record; 86 of the 86 references it cites were found in a registry or an index.
Recent development of mechanisms and control strategies for robot-assisted lower limb rehabilitation
Abstract
Robot-assisted rehabilitation and therapy has become more and more frequently used to help the elderly, disabled patients or movement disorders to perform exercise and training. The field of robot-assisted lower limb rehabilitation has rapidly evolved in the last decade. This article presents a review on the most recent progress (from year 2001 to 2014) of mechanisms, training modes and control strategies for lower limb rehabilitation robots. Special attention is paid to the adaptive robot control methods considering hybrid data fusion and patient evaluation in robot-assisted passive and active lower limb rehabilitation. The characteristics and clinical outcomes of different training modes and control algorithms in recent studies are analysed and summarized. Research gaps and future directions are also highlighted in this paper to improve the outcome of robot-assisted rehabilitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Knowledge-Based Intelligent Information and Engineering Systems
高下, 大., タカシタ, タ., Takashita, T., Jain, L. C., イトカワ, ツ., Itokawa, T., 北須賀, 輝., キタスカ, テ., Kitasuka, T., 有次, 正., et al. (2008) · Lecture notes in computer science · doi:10.1007/978-3-540-85565-1 · Cited by 1,699
Effects of Robot-Assisted Therapy on Upper Limb Recovery After Stroke: A Systematic Review
Kwakkel, G., Kollen, B. J., & Krebs, H. I. (2008) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968307305457 · Cited by 1,503
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327
Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)
Zoss, A. B., Kazerooni, H., & Chu, A. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871087 · Cited by 1,170
Robot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751
Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
Blaya, J. A., & Herr, H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.823266 · Cited by 741
Patient- cooperative strategies for robot-aided treadmill training: first experimental results
Riener, R., Lunenburger, L., Jezernik, S., Anderschitz, M., Colombo, G., & Dietz, V. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848628 · Cited by 729
Rehabilitation Robotics: Performance-Based Progressive Robot-Assisted Therapy
Krebs, H. I., Palazzolo, J. J., Dipietro, L., Ferraro, M., Krol, J., Rannekleiv, K., Volpe, B. T., & Hogan, N. (2003) · Autonomous Robots · doi:10.1023/a:1024494031121 · Cited by 714
Robot-based hand motor therapy after stroke
Takahashi, C. D., Der-Yeghiaian, L., Le, V., Motiwala, R. R., & Cramer, S. C. (2008) · Brain · doi:10.1093/brain/awm311 · Cited by 624
Exoskeleton robots for upper-limb rehabilitation: State of the art and future prospects
Lo, H. S., & Xie, S. Q. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.10.004 · Cited by 571
Self-citationHuang, H., Zhang, F., Hargrove, L. J., Dou, Z., Rogers, D. R., & Englehart, K. B. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2161671 · Cited by 542
Lower-Limb Robotic Rehabilitation: Literature Review and Challenges
Díaz, I., Gil, J. J., & Sánchez, E. (2011) · Journal of Robotics · doi:10.1155/2011/759764 · Cited by 541
An EMG-Based Control for an Upper-Limb Power-Assist Exoskeleton Robot
Kiguchi, K., & Hayashi, Y. (2012) · IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics) · doi:10.1109/tsmcb.2012.2185843 · Cited by 531
Optimizing Compliant, Model-Based Robotic Assistance to Promote Neurorehabilitation
Wolbrecht, E. T., Chan, V., Reinkensmeyer, D. J., & Bobrow, J. E. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.918389 · Cited by 506
A human-assisting manipulator teleoperated by EMG signals and arm motions
Fukuda, O., Tsuji, T., Kaneko, M., & Otsuka, A. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.808873 · Cited by 483
HAL: Hybrid Assistive Limb Based on Cybernics
Sankai, Y. (2010) · Springer Tracts in Advanced Robotics · doi:10.1007/978-3-642-14743-2_3 · Cited by 479
Lower Limb Wearable Robots for Assistance and Rehabilitation: A State of the Art
Huo, W., Mohammed, S., Moreno, J. C., & Amirat, Y. (2016) · IEEE Systems Journal · doi:10.1109/jsyst.2014.2351491 · Cited by 455
Multiclass Real-Time Intent Recognition of a Powered Lower Limb Prosthesis
Varol, H. A., Sup, F., & Goldfarb, M. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2034734 · Cited by 425
Path Control: A Method for Patient-Cooperative Robot-Aided Gait Rehabilitation
Duschau-Wicke, A., von Zitzewitz, J., Caprez, A., Lunenburger, L., & Riener, R. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2033061 · Cited by 421
Intention-Based EMG Control for Powered Exoskeletons
Lenzi, T., De Rossi, S. M. M., Vitiello, N., & Carrozza, M. C. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2198821 · Cited by 400
Power assist method for HAL-3 using EMG-based feedback controller
Kawamoto, H., Lee, S., Kanbe, S., & Sankai, Y. (2004) · SMC'03 Conference Proceedings. 2003 IEEE International Conference on Systems, Man and Cybernetics. Conference Theme - System Security and Assurance (Cat. No.03CH37483) · doi:10.1109/icsmc.2003.1244649 · Cited by 392
Design strategies to improve patient motivation during robot-aided rehabilitation
Colombo, R., Pisano, F., Mazzone, A., Delconte, C., Micera, S., Carrozza, M. C., Dario, P., & Minuco, G. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-3 · Cited by 385
Hybrid Control of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Kazerooni, H., Steger, R., & Huang, L. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906065505 · Cited by 382
Upper and lower extremity robotic devices for rehabilitation and for studying motor control
Hesse, S., Schmidt, H., Werner, C., & Bardeleben, A. (2003) · Current Opinion in Neurology · doi:10.1097/00019052-200312000-00010 · Cited by 369
Neuro-Fuzzy Control of a Robotic Exoskeleton With EMG Signals
Kiguchi, K., Tanaka, T., & Fukuda, T. (2004) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2004.832525 · Cited by 364
Cai, L. L., Fong, A. J., Otoshi, C. K., Liang, Y., Burdick, J. W., Roy, R. R., & Edgerton, V. R. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.2266-06.2006 · Cited by 344
An improved powered ankle–foot orthosis using proportional myoelectric control
Ferris, D. P., Gordon, K. E., Sawicki, G. S., & Peethambaran, A. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.05.004 · Cited by 342
Robot-Aided Neurorehabilitation: A Novel Robot for Ankle Rehabilitation
Roy, A., Krebs, H. I., Williams, D. J., Bever, C. T., Forrester, L. W., Macko, R. M., & Hogan, N. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2019783 · Cited by 337
Active Leg Exoskeleton (ALEX) for Gait Rehabilitation of Motor-Impaired Patients
Banala, S. K., Agrawal, S. K., & Scholz, J. P. (2007) · 2007 IEEE 10th International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428456 · Cited by 316
Jiménez-Fabián, R., & Verlinden, O. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.11.018 · Cited by 313
Emken, J. L., & Reinkensmeyer, D. J. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.843173 · Cited by 300
Lum, P. S., Burgar, C. G., & Shor, P. C. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.827225 · Cited by 281
NEUROExos: a powered elbow exoskeleton for physical rehabilitation
Vitiello, N., Lenzi, T., Roccella, S., De Rossi, S. M. M., Cattin, E., Giovacchini, F., Vecchi, F., & Carrozza, M. C. (2013) · IEEE Transactions on Robotics · doi:10.1109/tro.2012.2211492 · Cited by 272
Gait rehabilitation machines based on programmable footplates
Schmidt, H., Werner, C., Bernhardt, R., Hesse, S., & Krüger, J. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-2 · Cited by 256
A pneumatically powered knee-ankle-foot orthosis (KAFO) with myoelectric activation and inhibition
Sawicki, G. S., & Ferris, D. P. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-23 · Cited by 248
A Stewart Platform-Based System for Ankle Telerehabilitation
Girone, M., Burdea, G., Bouzit, M., Popescu, V., & Deutsch, J. E. (2001) · Autonomous Robots · doi:10.1023/a:1008938121020 · Cited by 236
The design and control of a therapeutic exercise robot for lower limb rehabilitation: Physiotherabot
Akdoğan, E., & Adli, M. A. (2011) · Mechatronics · doi:10.1016/j.mechatronics.2011.01.005 · Cited by 228
Reference Trajectory Generation for Rehabilitation Robots: Complementary Limb Motion Estimation
Vallery, H., van Asseldonk, E. H. F., Buss, M., & van der Kooij, H. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008278 · Cited by 228
Hesse, S., Waldner, A., & Tomelleri, C. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-30 · Cited by 225
Adaptive Impedance Control of a Robotic Orthosis for Gait Rehabilitation
Hussain, S., Xie, S. Q., & Jamwal, P. K. (2013) · IEEE Transactions on Cybernetics · doi:10.1109/tsmcb.2012.2222374 · Cited by 223
Self-citationFreivogel, S., Mehrholz, J., Husak-Sotomayor, T., & Schmalohr, D. (2008) · Brain Injury · doi:10.1080/02699050801941771 · Cited by 216
Powered Lower Limb Orthoses for Gait Rehabilitation
Ferris, D., Sawicki, G., & Domingo, A. (2005) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/6gl4-um7x-519h-9jyd · Cited by 214
sEMG-based continuous estimation of joint angles of human legs by using BP neural network
Zhang, F., Li, P., Hou, Z.-G., Lu, Z., Chen, Y., Li, Q., & Tan, M. (2012) · Neurocomputing · doi:10.1016/j.neucom.2011.05.033 · Cited by 202
EMG and EPP-integrated human-machine interface between the paralyzed and rehabilitation exoskeleton
Yin, Y. H., Fan, Y. J., & Xu, L. D. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2178034 · Cited by 197
Song, R., Tong, K.-Y., Hu, X., & Li, L. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.926707 · Cited by 195
ARMin - Exoskeleton for Arm Therapy in Stroke Patients
Nef, T., Mihelj, M., Kiefer, G., Perndl, C., Muller, R., & Riener, R. (2007) · 2007 IEEE 10th International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428408 · Cited by 192
Control Strategies for Patient-Assisted Training Using the Ankle Rehabilitation Robot (ARBOT)
Saglia, J. A., Tsagarakis, N. G., Dai, J. S., & Caldwell, D. G. (2013) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2012.2214228 · Cited by 179
Ju, M.-S., Lin, C.-C. K., Lin, D.-H., Hwang, I.-S., & Chen, S.-M. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847354 · Cited by 179
Development of a 3DOF mobile exoskeleton robot for human upper-limb motion assist
Kiguchi, K., Rahman, M. H., Sasaki, M., & Teramoto, K. (2008) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2007.11.007 · Cited by 178
Robotic Technologies and Rehabilitation: New Tools for Stroke Patients’ Therapy
Poli, P., Morone, G., Rosati, G., & Masiero, S. (2013) · BioMed Research International · doi:10.1155/2013/153872 · Cited by 177
Duschau-Wicke, A., Caprez, A., & Riener, R. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-43 · Cited by 175
Cesqui, B., Tropea, P., Micera, S., & Krebs, H. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-75 · Cited by 173
Hybrid Force-Position Control Yields Cooperative Behaviour of the Rehabilitation Robot Lokomat
Bernhardt, M., Frey, M., Colombo, G., & Riener, R. (2005) · 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005. · doi:10.1109/icorr.2005.1501159 · Cited by 172
Post-Stroke Rehabilitation with the Rutgers Ankle System: A Case Study
Deutsch, J. E., Latonio, J., Burdea, G. C., & Boian, R. (2001) · Presence: Teleoperators and Virtual Environments · doi:10.1162/1054746011470262 · Cited by 166
Human-centered robotics applied to gait training and assessment
Riener, R., Lünenburger, L., & Colombo, G. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.02.0046 · Cited by 161
Assessment of Motion of a Swing Leg and Gait Rehabilitation With a Gravity Balancing Exoskeleton
Agrawal, S. K., Banala, S. K., Fattah, A., Sangwan, V., Krishnamoorthy, V., Scholz, J. P., & Hsu, W. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903930 · Cited by 154
Cao, J., Xie, S. Q., Das, R., & Zhu, G. L. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.08.005 · Cited by 153
Self-citationYoon, J., Novandy, B., Yoon, C. H., & Park, K. (2010) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2010.2040834 · Cited by 149
Application of EMG signals for controlling exoskeleton robots
Fleischer, C., Wege, A., Kondak, K., & Hommel, G. (2006) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2006.063 · Cited by 138
Robotic lower limb exoskeletons using proportional myoelectric control
Ferris, D. P., & Lewis, C. L. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333984 · Cited by 136
Predicting the intended motion with EMG signals for an exoskeleton orthosis controller
Fleischer, C., Reinicke, C., & Hommel, G. (2005) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2005.1545504 · Cited by 134
Emken, J. L., Harkema, S. J., Beres-Jones, J. A., Ferreira, C. K., & Reinkensmeyer, D. J. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.910683 · Cited by 131
Robot assisted treadmill training: Mechanisms and training strategies
Hussain, S., Xie, S. Q., & Liu, G. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.12.010 · Cited by 113
Self-citationFleerkotte, B. M., Koopman, B., Buurke, J. H., van Asseldonk, E. H. F., van der Kooij, H., & Rietman, J. S. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-26 · Cited by 110
Lower-Limb Movement Assistance through Wearable Robots: State of the Art and Challenges
Mohammed, S., Amirat, Y., & Rifaï, H. (2012) · Advanced Robotics · doi:10.1163/016918611x607356 · Cited by 108
Myoelectrically controlled wrist robot for stroke rehabilitation
Song, R., Tong, R. K., Hu, X., & Zhou, W. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-52 · Cited by 108
Self-adaptive robot training of stroke survivors for continuous tracking movements
Vergaro, E., Casadio, M., Squeri, V., Giannoni, P., Morasso, P., & Sanguineti, V. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-13 · Cited by 106
Interactive robots for neuro-rehabilitation
Hogan, N., & Krebs, H. I. (2004) · Restorative Neurology and Neuroscience · doi:10.3233/rnn-2004-00277 · Cited by 104
Design and Control of a Lower Limb Exoskeleton for Robot-Assisted Gait Training
Beyl, P., Damme, M. V., Ham, R. V., Vanderborght, B., & Lefeber, D. (2009) · Applied Bionics and Biomechanics · doi:10.1080/11762320902784393 · Cited by 93
Robot-assisted practice of gait and stair climbing in nonambulatory stroke patients
Hesse, S., Tomelleri, C., Bardeleben, A., et al. (2012) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.08.0142 · Cited by 86
Robust Nonlinear Control of an Intrinsically Compliant Robotic Gait Training Orthosis
Hussain, S., Xie, S. Q., & Jamwal, P. K. (2012) · IEEE Transactions on Systems Man and Cybernetics Systems · doi:10.1109/tsmca.2012.2207111 · Cited by 86
Self-citationZhang, J., Dong, Y., Yang, C.-J., Geng, Y., Chen, Y., & Yang, Y. (2010) · Mechatronics · doi:10.1016/j.mechatronics.2010.02.003 · Cited by 86
Real-time pinch force estimation by surface electromyography using an artificial neural network
Choi, C., Kwon, S., Park, W., Lee, H., & Kim, J. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.04.004 · Cited by 83
Koopman, B., van Asseldonk, E. H. F., & van der Kooij, H. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-3 · Cited by 76
Knee rehabilitation using an intelligent robotic system
Akdoğan, E., Taçgın, E., & Adli, M. A. (2009) · Journal of Intelligent Manufacturing · doi:10.1007/s10845-008-0225-y · Cited by 74
Stiffness and Impedance Control Using Lyapunov Theory for Robot-Aided Rehabilitation
Mehdi, H., & Boubaker, O. (2011) · International Journal of Social Robotics · doi:10.1007/s12369-011-0128-5 · Cited by 72
Selective control of a subtask of walking in a robotic gait trainer(LOPES)
van Asseldonk, E. H. F., Ekkelenkamp, R., Veneman, J. F., van der Helm, F. C. T., & van der Kooij, H. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428522 · Cited by 58
Dual Stewart Platform Mobility Simulator
Boian, R., Bouzit, M., Burdea, G., Lewis, J., & Deutsch, J. E. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1502023 · Cited by 54
Surface EMG for force control of mechanical hands
Castellini, C., van der Smagt, P., Sandini, G., & Hirzinger, G. (2008) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2008.4543291 · Cited by 54
Symmetry-based resistance as a novel means of lower limb rehabilitation
Simon, A. M., Gillespie, R. B., & Ferris, D. P. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.05.021 · Cited by 40
An EMG-Controlled SMA Device for the Rehabilitation of the Ankle Joint in Post-Acute Stroke
Pittaccio, S., & Viscuso, S. (2011) · Journal of Materials Engineering and Performance · doi:10.1007/s11665-010-9826-7 · Cited by 40
Meng, W., Liu, Q., Zhou, Z., & Ai, Q. (2014) · Industrial Robot the international journal of robotics research and application · doi:10.1108/ir-04-2014-0327 · Cited by 35
Self-citationAkdoğan, E., Shima, K., Kataoka, H., Hasegawa, M., Otsuka, A., & Tsuji, T. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2198496 · Cited by 29
A Muscular Activation Controlled Rehabilitation Robot System
Akdoğan, E., & Şişman, Z. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-23851-2_28 · Cited by 6
Cited by
A Review on Design of Upper Limb Exoskeletons
Gull, M. A., Bai, S., & Bak, T. (2020) · Robotics · doi:10.3390/robotics9010016 · Cited by 435
Systematic review on wearable lower-limb exoskeletons for gait training in neuromuscular impairments
Rodríguez-Fernández, A., Lobo-Prat, J., & Font-Llagunes, J. M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00815-5 · Cited by 435
Metadata
- Authors
- Meng, W., Liu, Q., Zhou, Z., Ai, Q., Sheng, B., & Xie, S. (.
- Venue
- Mechatronics
- Publisher
- Elsevier BV
- Published
- 2015-10
- Volume
- 31
- Pages
- 132-145
- ISSN
- 0957-4158 (ISSN-L)
- OpenAlex
- W2062939404
- Cited by
- 464
- References
- 86
- FWCI
- 18.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.