STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 901–1,000 of 47,868
Naredo, E., Möller, I., Cruz, A., Carmona, L., & Garrido, J. (2008) · Arthritis & Rheumatism · doi:10.1002/art.23682 · Cited by 266
Measuring food intake with digital photography
Martin, C. K., Nicklas, T., Gunturk, B., Correa, J. B., Allen, H. R., & Champagne, C. (2014) · Journal of Human Nutrition and Dietetics · doi:10.1111/jhn.12014 · Cited by 261
The DASH and the QuickDASH instruments. Normative values in the general population in Norway
Aasheim, T., & Finsen, V. (2014) · Journal of Hand Surgery (European Volume) · doi:10.1177/1753193413481302 · Cited by 258
Maurer, A., Fucentese, S. F., Pfirrmann, C. W. A., Wirth, S. H., Djahangiri, A., Jost, B., & Gerber, C. (2012) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2011.07.010 · Cited by 261
Performance measure characterization for evaluating neuroimage segmentation algorithms
Chang, H.-H., Zhuang, A. H., Valentino, D. J., & Chu, W.-C. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.03.068 · Cited by 262
Edvardsen, T., Skulstad, H., Aakhus, S., Urheim, S., & Ihlen, H. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01160-8 · Cited by 262
The future of computer-aided sperm analysis
Mortimer, D., Mortimer, S., & Horst, G. D. (2015) · Asian Journal of Andrology · doi:10.4103/1008-682x.154312 · Cited by 251
Stone, G. J., Young, W. L., Smith, C. R., Solomon, R. A., Wald, A., Ostapkovich, N., & Shrebnick, D. B. (1995) · Anesthesiology · doi:10.1097/00000542-199502000-00004 · Cited by 260
Dweck, M. R., Jenkins, W. S. A., Vesey, A. T., Pringle, M. A. H., Chin, C. W. L., Malley, T. S., Cowie, W. J. A., Tsampasian, V., Richardson, H., Fletcher, A., et al. (2014) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.113.001508 · Cited by 260
Measurement of Blood Pressure in the Office: Recognizing the Problem and Proposing the Solution
Myers, M. G., Godwin, M., Dawes, M., Kiss, A., Tobe, S. W., & Kaczorowski, J. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.141879 · Cited by 260
Coleman, A., Steel, S., Freeman, P., de Greeff, A., & Shennan, A. (2008) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3282cb57b6 · Cited by 259
Reproducibility of real-time shear wave elastography in the evaluation of liver elasticity
Ferraioli, G., Tinelli, C., Zicchetti, M., Above, E., Poma, G., Di Gregorio, M., & Filice, C. (2012) · European Journal of Radiology · doi:10.1016/j.ejrad.2012.05.030 · Cited by 260
Maddison, R., Ni Mhurchu, C., Jiang, Y., Vander Hoorn, S., Rodgers, A., Lawes, C. M., & Rush, E. (2007) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-4-62 · Cited by 255
Comparison of insulin sensitivity tests across a range of glucose tolerance from normal to diabetes
Hermans, M. P., Levy, J. C., Morris, R. J., & Turner, R. C. (1999) · Diabetologia · doi:10.1007/s001250051215 · Cited by 260
MCHORNEY, C. A., & WARE, J. E. (1995) · Medical Care · doi:10.1097/00005650-199501000-00002 · Cited by 260
Clausen, J. O., Borch-Johnsen, K., Ibsen, H., Bergman, R. N., Hougaard, P., Winther, K., & Pedersen, O. (1996) · Journal of Clinical Investigation · doi:10.1172/jci118903 · Cited by 259
Sikaris, K., McLachlan, R. I., Kazlauskas, R., de Kretser, D., Holden, C. A., & Handelsman, D. J. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2005-0962 · Cited by 259
The replication rate of human hematopoietic stem cells in vivo
Catlin, S. N., Busque, L., Gale, R. E., Guttorp, P., & Abkowitz, J. L. (2011) · Blood · doi:10.1182/blood-2010-08-303537 · Cited by 259
Snijder, M., Visser, M., Dekker, J., Seidell, J., Fuerst, T., Tylavsky, F., Cauley, J., Lang, T., Nevitt, M., & Harris, T. (2002) · International Journal of Obesity · doi:10.1038/sj.ijo.0801968 · Cited by 260
Validity of Web-Based Self-Reported Weight and Height: Results of the Nutrinet-Santé Study
Lassale, C., Péneau, S., Touvier, M., Julia, C., Galan, P., Hercberg, S., & Kesse-Guyot, E. (2013) · Journal of Medical Internet Research · doi:10.2196/jmir.2575 · Cited by 259
Automated lung segmentation for thoracic CT
Armato, S. G., & Sensakovic, W. F. (2004) · Academic Radiology · doi:10.1016/j.acra.2004.06.005 · Cited by 259
Monitoring Fatigue During the In-Season Competitive Phase in Elite Soccer Players
Thorpe, R. T., Strudwick, A. J., Buchheit, M., Atkinson, G., Drust, B., & Gregson, W. (2015) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2015-0004 · Cited by 255
Galna, B., Lord, S., & Rochester, L. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2012.09.025 · Cited by 254
Kato, S., Oshima, Y., Oka, H., Chikuda, H., Takeshita, Y., Miyoshi, K., Kawamura, N., Masuda, K., Kunogi, J., Okazaki, R., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0123022 · Cited by 255
Intra-abdominal hypertension in the critically ill: it is time to pay attention
Malbrain, M. L. N. G., Deeren, D., & De Potter, T. J. R. (2005) · Current Opinion in Critical Care · doi:10.1097/01.ccx.0000155355.86241.1b · Cited by 261
Knowles, C. H., Eccersley, J. A., Scott, M. S., Walker, S. M., Reeves, B., & Lunniss, P. J. (2000) · Diseases of the Colon & Rectum · doi:10.1007/bf02236639 · Cited by 259
Dougados, M., Combe, B., Cantagrel, A., Goupille, P., Olive, P., Schattenkirchner, M., Meusser, S., Paimela, L., Rau, R., Zeidler, H., et al. (1999) · Annals of the Rheumatic Diseases · doi:10.1136/ard.58.4.220 · Cited by 259
Craig, J. V. (2000) · BMJ · doi:10.1136/bmj.320.7243.1174 · Cited by 264
Juergens, K. U., Grude, M., Maintz, D., Fallenberg, E. M., Wichter, T., Heindel, W., & Fischbach, R. (2004) · Radiology · doi:10.1148/radiol.2302030042 · Cited by 261
Improving the Reliability of the Pelli-Robson Contrast Sensitivity Test
Bullimore, M. A., Elliot, D. B., & Bailey, I. L. (1991) · Noninvasive Assessment of the Visual System · doi:10.1364/navs.1991.md12 · Cited by 253
Zhang, S., Faries, D. E., Vowles, M., & Michelson, D. (2005) · International Journal of Methods in Psychiatric Research · doi:10.1002/mpr.7 · Cited by 255
Clinimetric review of motion sensors in children and adolescents
de Vries, S. I., Bakker, I., Hopman-Rock, M., Hirasing, R. A., & van Mechelen, W. (2006) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.11.020 · Cited by 257
The psychometric properties of clinical rating scales used in multiple sclerosis
Sharrack, B., Hughes, R. A. C., Soudain, S., & Dunn, G. (1999) · Brain · doi:10.1093/brain/122.1.141 · Cited by 258
Prostate Cancer Tumor Volume: Measurement with Endorectal MR and MR Spectroscopic Imaging
Coakley, F. V., Kurhanewicz, J., Lu, Y., Jones, K. D., Swanson, M. G., Chang, S. D., Carroll, P. R., & Hricak, H. (2002) · Radiology · doi:10.1148/radiol.2231010575 · Cited by 258
Nutritional assessment with bioelectrical impedance analysis in maintenance hemodialysis patients.
Chertow, G. M., Lowrie, E. G., Wilmore, D. W., Gonzalez, J., Lew, N. L., Ling, J., Leboff, M. S., Gottlieb, M. N., Huang, W., & Zebrowski, B. (1995) · Journal of the American Society of Nephrology · doi:10.1681/asn.v6175 · Cited by 257
Bedside methods versus dual energy X‐ray absorptiometry for body composition measurement in COPD
Steiner, M. C., Barton, R. L., Singh, S. J., & Morgan, M. D. L. (2002) · European Respiratory Journal · doi:10.1183/09031936.02.00279602 · Cited by 256
Equivalence of two healthcare costing methods: bottom-up and top-down
Chapko, M. K., Liu, C., Perkins, M., Li, Y., Fortney, J. C., & Maciejewski, M. L. (2009) · Health Economics · doi:10.1002/hec.1422 · Cited by 256
Chaibi, Y., Cresson, T., Aubert, B., Hausselle, J., Neyret, P., Hauger, O., de Guise, J. A., & Skalli, W. (2012) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2010.540758 · Cited by 255
Influence of Sex on Arterial Hemodynamics and Blood Pressure: Role of Body Height
London, G. M., Guerin, A. P., Pannier, B., Marchais, S. J., & Stimpel, M. (1995) · Hypertension · doi:10.1161/01.hyp.26.3.514 · Cited by 258
Quantitative estimation of foot-flat and stance phase of gait using foot-worn inertial sensors
Mariani, B., Rouhani, H., Crevoisier, X., & Aminian, K. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2012.07.012 · Cited by 258
Plein, S., Bloomer, T. N., Ridgway, J. P., Jones, T. R., Bainbridge, G. J., & Sivananthan, M. U. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1178 · Cited by 257
The relationship between visual resolution and cone spacing in the human fovea
Rossi, E. A., & Roorda, A. (2010) · Nature Neuroscience · doi:10.1038/nn.2465 · Cited by 255
Measuring fMRI reliability with the intra-class correlation coefficient
Caceres, A., Hall, D. L., Zelaya, F. O., Williams, S. C. R., & Mehta, M. A. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.035 · Cited by 255
Tossici-Bolt, L., Hoffmann, S. M. A., Kemp, P. M., Mehta, R. L., & Fleming, J. S. (2006) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0155-x · Cited by 259
Comparison of three generations of ActiGraph™ activity monitors in children and adolescents
Robusto, K. M., & Trost, S. G. (2012) · Journal of Sports Sciences · doi:10.1080/02640414.2012.710761 · Cited by 254
Hypoalgesic and Sympathoexcitatory Effects of Mobilization With Movement for Lateral Epicondylalgia
Paungmali, A., O'Leary, S., Souvlis, T., & Vicenzino, B. (2003) · Physical Therapy · doi:10.1093/ptj/83.4.374 · Cited by 258
Castaldo, R., Montesinos, L., Melillo, P., James, C., & Pecchia, L. (2019) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-019-0742-y · Cited by 246
Automated analysis of digital oximetry in the diagnosis of obstructive sleep apnoea
Vazquez, J.-C. (2000) · Thorax · doi:10.1136/thorax.55.4.302 · Cited by 254
Simple Microplate Method for Determination of Urinary Iodine
Ohashi, T., Yamaki, M., Pandav, C. S., Karmarkar, M. G., & Irie, M. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.4.529 · Cited by 255
Seiler, C., Fleisch, M., Garachemani, A., & Meier, B. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00384-2 · Cited by 255
Grünheid, T., McCarthy, S. D., & Larson, B. E. (2014) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2014.07.023 · Cited by 245
Olson, J. E., Shu, X. O., Ross, J. A., Pendergrass, T., & Robison, L. L. (1997) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a009032 · Cited by 255
on behalf of the HELENA Study Group, Vereecken, C. A., Covents, M., Sichert-Hellert, W., Alvira, J. M. F., Le Donne, C., De Henauw, S., De Vriendt, T., Phillipp, M. K., Béghin, L., et al. (2008) · International Journal of Obesity · doi:10.1038/ijo.2008.180 · Cited by 255
Lambert, R. G. W., Salonen, D., Rahman, P., Inman, R. D., Wong, R. L., Einstein, S. G., Thomson, G. T. D., Beaulieu, A., Choquette, D., & Maksymowych, W. P. (2007) · Arthritis & Rheumatism · doi:10.1002/art.23044 · Cited by 256
A comparison of two methods for measuring the signal to noise ratio on MR images
Firbank, M. J., Coulthard, A., Harrison, R. M., & Williams, E. D. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/12/403 · Cited by 256
Cho, G.-Y., Chan, J., Leano, R., Strudwick, M., & Marwick, T. H. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.12.063 · Cited by 255
Measurement properties of the CESD scale among individuals with spinal cord injury
Miller, W. C., Anton, H. A., & Townson, A. F. (2008) · Spinal Cord · doi:10.1038/sj.sc.3102127 · Cited by 249
White-Koning, M., Arnaud, C., Dickinson, H. O., Thyen, U., Beckung, E., Fauconnier, J., McManus, V., Michelsen, S. I., Parkes, J., Parkinson, K., et al. (2007) · Pediatrics · doi:10.1542/peds.2006-3272 · Cited by 255
Corder, K., van Sluijs, E. M., Wright, A., Whincup, P., Wareham, N. J., & Ekelund, U. (2009) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.2008.26739 · Cited by 253
Zou, G. (2013) · Statistical Methods in Medical Research · doi:10.1177/0962280211402548 · Cited by 253
Validation of self-reported height and weight in a large, nationwide cohort of U.S. adults
Hodge, J. M., Shah, R., McCullough, M. L., Gapstur, S. M., & Patel, A. V. (2020) · PLOS ONE · doi:10.1371/journal.pone.0231229 · Cited by 251
Shirreffs, S. M., & Maughan, R. J. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.1.336 · Cited by 251
Retinal thickness study with optical coherence tomography in patients with diabetes.
Sánchez-Tocino, H., Alvárez-Vidal, A., Maldonado, M. J., Moreno‐Montañés, J., & García‐Layana, A. (2002) · PubMed · Cited by 251
Demers, L., Monette, M., Lapierre, Y., Arnold, D. L., & Wolfson, C. (2002) · Disability and Rehabilitation · doi:10.1080/09638280110066352 · Cited by 249
Quantification of Myocardial Perfusion Using Dynamic 64-Detector Computed Tomography
George, R. T., Jerosch-Herold, M., Silva, C., Kitagawa, K., Bluemke, D. A., Lima, J. A. C., & Lardo, A. C. (2007) · Investigative Radiology · doi:10.1097/rli.0b013e318124a884 · Cited by 251
HOEPER, M. M., MAIER, R., TONGERS, J., NIEDERMEYER, J., HOHLFELD, J. M., HAMM, M., & FABEL, H. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.2.9811062 · Cited by 256
Correlation, Agreement, and Bland–Altman Analysis: Statistical Analysis of Method Comparison Studies
Bunce, C. (2009) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2008.09.032 · Cited by 250
Lüssea, S., Claassen, H., Gehrke, T., Hassenpflug, J., Schünke, M., Heller, M., & Glüer, C.-C. (2000) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(99)00144-7 · Cited by 252
Use of dual-energy X-ray absorptiometry in obese individuals
Tataranni, P., & Ravussin, E. (1995) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/62.4.730 · Cited by 250
Hurtig-Wennlöf, A., Hagströmer, M., & Olsson, L. A. (2010) · Public Health Nutrition · doi:10.1017/s1368980010000157 · Cited by 249
O’Keeffe, S. T., Lye, M., Donnellan, C., & Carmichael, D. N. (1998) · Heart · doi:10.1136/hrt.80.4.377 · Cited by 250
Omboni, S., Parati, G., Palatini, P., Vanasia, A., Muiesan, M. L., Cuspidi, C., & Mancia, G. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816060-00003 · Cited by 251
Marra, D. E., Hamlet, K. M., Bauer, R. M., & Bowers, D. (2020) · The Clinical Neuropsychologist · doi:10.1080/13854046.2020.1769192 · Cited by 251
Short‐and Long‐Term Reproducibility of QT, QTc, and QT Dispersion Measurement in Healthy Subjects
KAUTZNER, J., YI, G., CAMM, A. J., & MALIK, M. (1994) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1994.tb01435.x · Cited by 250
Rehabilitative Ultrasound Imaging: Understanding the Technology and Its Applications
Whittaker, J. L., Teyhen, D. S., Elliott, J. M., Cook, K., Langevin, H. M., Dahl, H. H., & Stokes, M. (2007) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2007.2350 · Cited by 250
Endocan, a new endothelial marker in human sepsis*
Scherpereel, A., Depontieu, F., Grigoriu, B., Cavestri, B., Tsicopoulos, A., Gentina, T., Jourdain, M., Pugin, J., Tonnel, A.-B., & Lassalle, P. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000198525.82124.74 · Cited by 249
Agreed Statistics: Measurement Method Comparison
Bland, J. M., Altman, D. G., & Warner, D. S. (2012) · Anesthesiology · doi:10.1097/aln.0b013e31823d7784 · Cited by 252
Self-citationChoroidal thickness changes during altered eye growth and refractive state in a primate.
Troilo, D., Nickla, D. L., & Wildsoet, C. F. (2000) · PubMed · Cited by 267
Assessment of Trending Ability of Cardiac Output Monitors by Polar Plot Methodology
Critchley, L. A. H., Yang, X. X., & Lee, A. S. Y. (2011) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2011.01.003 · Cited by 248
Bonnefoy, M., Normand, S., Pachiaudi, C., Lacour, J. R., Laville, M., & Kostka, T. (2001) · Journal of the American Geriatrics Society · doi:10.1046/j.1532-5415.2001.49006.x · Cited by 247
Abdominal muscle size and symmetry in normal subjects
Rankin, G., Stokes, M., & Newham, D. J. (2006) · Muscle & Nerve · doi:10.1002/mus.20589 · Cited by 246
Hu, W., Zhao, Z., Wang, Y., Zhang, H., & Lin, F. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2288319 · Cited by 247
Zhang, C., & Ho, S. C. (2009) · PubMed · Cited by 271
Feltgen, N. (2001) · British Journal of Ophthalmology · doi:10.1136/bjo.85.1.85 · Cited by 238
End-expiratory lung impedance change enables bedside monitoring of end-expiratory lung volume change
Hinz, J., Hahn, G., Neumann, P., Sydow, M., Mohrenweiser, P., Hellige, G., & Burchardi, H. (2003) · Intensive Care Medicine · doi:10.1007/s00134-002-1555-4 · Cited by 248
Bull, R. K., Edwards, P. D., Kemp, P. M., Fry, S., & Hughes, I. A. (1999) · Archives of Disease in Childhood · doi:10.1136/adc.81.2.172 · Cited by 248
The Quality of Life Impact of Refractive Correction (QIRC) Questionnaire: Development and Validation
Pesudovs, K., Garamendi, E., & Elliott, D. B. (2004) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2004.tb01962.x · Cited by 242
Enzyme conversion immunoassay for determining total homocysteine in plasma or serum
Frantzen, F., Faaren, A. L., Alfheim, I., & Nordhei, A. K. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.2.311 · Cited by 252
Rodevand, O., Bjornerheim, R., Ljosland, M., Maehle, J., Smith, H. J., & Ihlen, H. (1999) · The International Journal of Cardiac Imaging · doi:10.1023/a:1006276513186 · Cited by 246
Winkler, A. M., Webster, M. A., Vidaurre, D., Nichols, T. E., & Smith, S. M. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.05.092 · Cited by 243
Massy-Westropp, N., Rankin, W., Ahern, M., Krishnan, J., & Hearn, T. C. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.01.012 · Cited by 247
Detection of Type, Duration, and Intensity of Physical Activity Using an Accelerometer
BONOMI, A. G., GORIS, A. H. C., YIN, B., & WESTERTERP, K. R. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181a24536 · Cited by 245
Human Chorioretinal Layer Thicknesses Measured in Macula-wide, High-Resolution Histologic Sections
Curcio, C. A., Messinger, J. D., Sloan, K. R., Mitra, A., McGwin, G., & Spaide, R. F. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6377 · Cited by 251
Huttner, H. B., Steiner, T., Hartmann, M., Köhrmann, M., Juettler, E., Mueller, S., Wikner, J., Meyding-Lamade, U., Schramm, P., Schwab, S., et al. (2006) · Stroke · doi:10.1161/01.str.0000198806.67472.5c · Cited by 246
Are dietary patterns stable throughout early and mid-childhood? A birth cohort study
Northstone, K., & Emmett, P. M. (2008) · British Journal of Nutrition · doi:10.1017/s0007114508968264 · Cited by 252
Hoyte, L., Schierlitz, L., Zou, K., Flesh, G., & Fielding, J. R. (2001) · American Journal of Obstetrics and Gynecology · doi:10.1067/mob.2001.116365 · Cited by 251
BISGAARD, H., LOLAND, L., & ØJ, J. A. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.4.9903004 · Cited by 249
Kyle, U. G., Genton, L., Hans, D., & Pichard, C. (2003) · Clinical Nutrition · doi:10.1016/s0261-5614(03)00048-7 · Cited by 248
Accuracy and reliability of a Cosmed K4b2 portable gas analysis system
Duffield, R., Dawson, B., Pinnington, H. C., & Wong, P. (2004) · Journal of Science and Medicine in Sport · doi:10.1016/s1440-2440(04)80039-2 · Cited by 246
Reporting Standards for a Bland–Altman Agreement Analysis: A Review of Methodological Reviews
Gerke, O. (2020) · Diagnostics · doi:10.3390/diagnostics10050334 · Cited by 246
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.