STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 801–900 of 47,868
Interrater reliability of Glasgow Coma Scale scores in the emergency department
Gill, M. R., Reiley, D. G., & Green, S. M. (2004) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(03)00814-x · Cited by 279
Validation of the Omron HEM-907 device for blood pressure measurement
El Assaad, M. A., Topouchian, J. A., Darné, B. M., & Asmar, R. G. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200208000-00006 · Cited by 279
Thompson, P., Beath, T., Bell, J., Jacobson, G., Phair, T., Salbach, N. M., & Wright, F. V. (2008) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.2008.02048.x · Cited by 272
Hoshino, M., Nakamura, Y., Sim, J., Shimojo, J., & Isogai, S. (1998) · Journal of Allergy and Clinical Immunology · doi:10.1016/s0091-6749(98)70018-1 · Cited by 281
McGowan, J. H., & Cleland, J. G. F. (2003) · American Heart Journal · doi:10.1016/s0002-8703(03)00248-5 · Cited by 279
Selected issues in the design and analysis of sport performance research
Atkinson, G., & Nevill, A. M. (2001) · Journal of Sports Sciences · doi:10.1080/026404101317015447 · Cited by 279
Validity of a food frequency questionnaire to assess nutritional intake among Sri Lankan adults
Jayawardena, R., Byrne, N. M., Soares, M. J., Katulanda, P., & Hills, A. P. (2016) · SpringerPlus · doi:10.1186/s40064-016-1837-x · Cited by 276
Hughes, S. W. (2005) · Physics Education · doi:10.1088/0031-9120/40/5/008 · Cited by 278
CT-Assessment of Dependent Lung Densities in Man during General Anaesthesia
Lundquist, H., Hedenstierna, G., Strandberg, Å., Tokics, L., & Brismar, B. (1995) · Acta Radiologica · doi:10.1177/028418519503600464 · Cited by 285
Zimmermann, M. B., Hess, S. Y., Molinari, L., de Benoist, B., Delange, F., Braverman, L. E., Fujieda, K., Ito, Y., Jooste, P. L., Moosa, K., et al. (2004) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/79.2.231 · Cited by 281
de Jong, J. R., Vlaeyen, J. W. S., Onghena, P., Cuypers, C., den Hollander, M., & Ruijgrok, J. (2005) · Pain · doi:10.1016/j.pain.2005.04.019 · Cited by 282
Wagner, J. M., Rhodes, J. A., & Patten, C. (2008) · Physical Therapy · doi:10.2522/ptj.20070255 · Cited by 280
Hemingway, H., Nicholson, A., Stafford, M., Roberts, R., & Marmot, M. (1997) · American Journal of Public Health · doi:10.2105/ajph.87.9.1484 · Cited by 284
Kowal‐Bielecka, O., Distler, O., Neidhart, M., K�nzler, P., Rethage, J., Nawrath, M., Carossino, A. M., Pap, T., M�ller-Ladner, U., Michel, B. A., et al. (2001) · Arthritis & Rheumatism · doi:10.1002/1529-0131(200108)44:8<1865::aid-art325>3.0.co;2-m · Cited by 44
German short forms of the Oral Health Impact Profile
John, M. T., Miglioretti, D. L., LeResche, L., Koepsell, T. D., Hujoel, P., & Micheelis, W. (2006) · Community Dentistry and Oral Epidemiology · doi:10.1111/j.1600-0528.2006.00279.x · Cited by 274
All‐digital image capture and whole‐field analysis of ciliary beat frequency
Sisson, J. H., Stoner, J. A., Ammons, B. A., & Wyatt, T. A. (2003) · Journal of Microscopy · doi:10.1046/j.1365-2818.2003.01209.x · Cited by 280
Variability in measurement of abdominal aortic aneurysms
Lederle, F. A., Wilson, S. E., Johnson, G. R., Reinke, D. B., Littooy, F. N., Acher, C. W., Messina, L. M., Ballard, D. J., & Ansel, H. J. (1995) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(95)70222-9 · Cited by 285
LIANG, Y.-L., TEEDE, H., KOTSOPOULOS, D., SHIEL, L., CAMERON, J. D., DART, A. M., & McGRATH, B. P. (1998) · Clinical Science · doi:10.1042/cs0950669 · Cited by 277
Stahl, S. E., An, H.-S., Dinkel, D. M., Noble, J. M., & Lee, J.-M. (2016) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2015-000106 · Cited by 276
Outcome evaluation measures for wrist and hand – which one to choose?
Changulani, M., Okonkwo, U., Keswani, T., & Kalairajah, Y. (2008) · International Orthopaedics · doi:10.1007/s00264-007-0368-z · Cited by 271
Heimbürger, O., Qureshi, A. R., Blaner, W. S., Berglund, L., & Stenvinkel, P. (2000) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2000.19837 · Cited by 276
Price, R. N., Cassar, C., Brockman, A., Duraisingh, M., van Vugt, M., White, N. J., Nosten, F., & Krishna, S. (1999) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.43.12.2943 · Cited by 279
Muir, S. W., Berg, K., Chesworth, B., Klar, N., & Speechley, M. (2010) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.06.010 · Cited by 271
Reliability and validity of two tests of soccer skill
Ali, A., Williams, C., Hulse, M., Strudwick, A., Reddin, J., Howarth, L., Eldred, J., Hirst, M., & McGregor, S. (2007) · Journal of Sports Sciences · doi:10.1080/02640410601150470 · Cited by 259
Optic disk ovality as an index of tilt and its relationship to myopia and perimetry
Tay, E., Seah, S. K., Chan, S.-P., Lim, A. T. H., Chew, S.-J., Foster, P. J., & Aung, T. (2005) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2004.08.076 · Cited by 278
Cameli, M., Lisi, M., Mondillo, S., Padeletti, M., Ballo, P., Tsioulpas, C., Bernazzali, S., & Maccherini, M. (2010) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-8-14 · Cited by 274
Continuous monitoring of deep-tissue haemodynamics with stretchable ultrasonic phased arrays
Wang, C., Qi, B., Lin, M., Zhang, Z., Makihata, M., Liu, B., Zhou, S., Huang, Y.-H., Hu, H., Gu, Y., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00763-4 · Cited by 274
Prediction of Energy Expenditure and Physical Activity in Preschoolers
BUTTE, N. F., WONG, W. W., LEE, J. S., ADOLPH, A. L., PUYAU, M. R., & ZAKERI, I. F. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000209 · Cited by 273
Piechnik, S. K., Ferreira, V. M., Lewandowski, A. J., Ntusi, N. A., Banerjee, R., Holloway, C., Hofman, M. B., Sado, D. M., Maestrini, V., White, S. K., et al. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-13 · Cited by 273
Glickman, S. G., Marn, C. S., Supiano, M. A., & Dengel, D. R. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01234.2003 · Cited by 274
Nilsson, A., Ekelund, U., Yngve, A., & Söström, M. (2002) · Pediatric Exercise Science · doi:10.1123/pes.14.1.87 · Cited by 271
Gorter, P. M., van Lindert, A. S. R., de Vos, A. M., Meijs, M. F. L., van der Graaf, Y., Doevendans, P. A., Prokop, M., & Visseren, F. L. J. (2008) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2007.08.016 · Cited by 273
Development of a self-reported Chronic Respiratory Questionnaire (CRQ-SR)
Williams, J. E. A. (2001) · Thorax · doi:10.1136/thorax.56.12.954 · Cited by 278
Tracer Kinetic Modeling of the 5-HT1AReceptor Ligand [carbonyl-11C]WAY-100635 for PET
Gunn, R. N., Sargent, P. A., Bench, C. J., Rabiner, E. A., Osman, S., Pike, V. W., Hume, S. P., Grasby, P. M., & Lammertsma, A. A. (1998) · NeuroImage · doi:10.1006/nimg.1998.0379 · Cited by 272
The reliability of the Pelli-Robson contrast sensitivity chart
Elliott, D. (1990) · Ophthalmic and Physiological Optics · doi:10.1016/0275-5408(90)90124-h · Cited by 272
Assessing Body Composition With DXA and Bioimpedance: Effects of Obesity, Physical Activity, and Age
Völgyi, E., Tylavsky, F. A., Lyytikäinen, A., Suominen, H., Alén, M., & Cheng, S. (2008) · Obesity · doi:10.1038/oby.2007.94 · Cited by 274
van Kampen, D. A., Willems, W., van Beers, L. W. A. H., Castelein, R. M., Scholtes, V. A. B., & Terwee, C. B. (2013) · Journal of Orthopaedic Surgery and Research · doi:10.1186/1749-799x-8-40 · Cited by 274
Morris, P. D., Ryan, D., Morton, A. C., Lycett, R., Lawford, P. V., Hose, D. R., & Gunn, J. P. (2013) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2012.08.024 · Cited by 270
Human bone marrow assessment by single-cell RNA sequencing, mass cytometry, and flow cytometry
Oetjen, K. A., Lindblad, K. E., Goswami, M., Gui, G., Dagur, P. K., Lai, C., Dillon, L. W., McCoy, J. P., & Hourigan, C. S. (2018) · JCI Insight · doi:10.1172/jci.insight.124928 · Cited by 272
Lo, I. K. Y., Griffin, S., & Kirkley, A. (2001) · Osteoarthritis and Cartilage · doi:10.1053/joca.2001.0474 · Cited by 274
Refining the Ten-metre Walking Test for Use with Neurologically Impaired People
Watson, M. J. (2002) · Physiotherapy · doi:10.1016/s0031-9406(05)61264-3 · Cited by 268
Bortolotto, L. A., Blacher, J., Kondo, T., Takazawa, K., & Safar, M. E. (2000) · American Journal of Hypertension · doi:10.1016/s0895-7061(99)00192-2 · Cited by 273
Methodological challenges in the evaluation of prognostic factors in breast cancer.
Altman, D. G., & Lyman, G. H. (1998) · Breast Cancer Research and Treatment · doi:10.1023/a:1006193704132 · Cited by 271
Self-citationTest-retest reliability of trunk accelerometry during standing and walking
Moe-Nilssen, R. (1998) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(98)90231-3 · Cited by 271
Owen, N. J., Watkins, J., Kilduff, L. P., Bevan, H. R., & Bennett, M. A. (2014) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000000311 · Cited by 271
Helbing, W. A., Bosch, H. G., Maliepaard, C., Rebergen, S. A., van der Geest, R. J., Hansen, B., Ottenkamp, J., Reiber, J. H. C., & de Roos, A. (1995) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)80161-1 · Cited by 271
Rapid Platelet-Function Assay: An Automated and Quantitative Cartridge-Based Method
Smith, J. W., Steinhubl, S. R., Lincoff, A. M., Coleman, J. C., Lee, T. T., Hillman, R. S., & Coller, B. S. (1999) · Circulation · doi:10.1161/01.cir.99.5.620 · Cited by 274
Measurement of the thickness of the fibrous cap by optical coherence tomography
Kume, T., Akasaka, T., Kawamoto, T., Okura, H., Watanabe, N., Toyota, E., Neishi, Y., Sukmawan, R., Sadahira, Y., & Yoshida, K. (2006) · American Heart Journal · doi:10.1016/j.ahj.2006.06.030 · Cited by 273
Kim, W. Y., Walker, P. G., Pedersen, E. M., Poulsen, J. K., Oyre, S., Houlind, K., & Yoganathan, A. P. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00141-l · Cited by 274
Thiele, H., Kappl, M. J. E., Conradi, S., Niebauer, J., Hambrecht, R., & Schuler, G. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.065 · Cited by 271
Rapid Quantitative Analysis of Lipids Using a Colorimetric Method in a Microplate Format
Cheng, Y., Zheng, Y., & VanderGheynst, J. S. (2011) · Lipids · doi:10.1007/s11745-010-3494-0 · Cited by 266
Martin, C. K., Correa, J. B., Han, H., Allen, H. R., Rood, J. C., Champagne, C. M., Gunturk, B. K., & Bray, G. A. (2012) · Obesity · doi:10.1038/oby.2011.344 · Cited by 272
Veehof, M. M., Sleegers, E. J. A., van Veldhoven, N. H. M. J., Schuurman, A. H., & van Meeteren, N. L. U. (2002) · Journal of Hand Therapy · doi:10.1016/s0894-1130(02)80006-0 · Cited by 269
Qualitative Attributes and Measurement Properties of Physical Activity Questionnaires: A Checklist
Terwee, C. B., Mokkink, L. B., van Poppel, M. N. M., Chinapaw, M. J. M., van Mechelen, W., & de Vet, H. C. W. (2010) · Sports Medicine · doi:10.2165/11531370-000000000-00000 · Cited by 269
Utility of automated brachial ankle pulse wave velocity measurements in hypertensive patients
Munakata, M. (2003) · American Journal of Hypertension · doi:10.1016/s0895-7061(03)00918-x · Cited by 269
Holdgate, A., Asha, S., Craig, J., & Thompson, J. (2003) · Emergency Medicine · doi:10.1046/j.1442-2026.2003.00499.x · Cited by 275
Bonnechère, B., Jansen, B., Salvia, P., Bouzahouene, H., Omelina, L., Moiseev, F., Sholukha, V., Cornelis, J., Rooze, M., & Van Sint Jan, S. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2013.09.018 · Cited by 267
Prediction equations for body composition of Japanese adults by B‐mode ultrasound
Abe, T., Kondo, M., Kawakami, Y., & Fukunaga, T. (1994) · American Journal of Human Biology · doi:10.1002/ajhb.1310060204 · Cited by 268
The Pedar® in-shoe system: Repeatability and normal pressure values
Putti, A. B., Arnold, G. P., Cochrane, L., & Abboud, R. J. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.05.010 · Cited by 272
van Royen, N., Jaffe, C. C., Krumholz, H. M., Johnson, K. M., Lynch, P. J., Natale, D., Atkinson, P., Demon, P., & Wackers, F. J. T. (1996) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)89179-5 · Cited by 270
Calibration of an accelerometer during free-living activities in children
Mattocks, C., Leary, S., Ness, A., Deere, K., Saunders, J., Tilling, K., Kirkby, J., Blair, S. N., & Riddoch, C. (2007) · International Journal of Pediatric Obesity · doi:10.1080/17477160701408809 · Cited by 271
TORTORIELLO, T. A., STAYER, S. A., MOTT, A. R., DEAN McKENZIE, E., FRASER, C. D., ANDROPOULOS, D. B., & CHANG, A. C. (2005) · Pediatric Anesthesia · doi:10.1111/j.1460-9592.2005.01488.x · Cited by 269
De Bruyne, B., Pijls, N. H. J., Heyndrickx, G. R., Hodeige, D., Kirkeeide, R., & Gould, K. L. (2000) · Circulation · doi:10.1161/01.cir.101.15.1840 · Cited by 266
Mansournia, M. A., Collins, G. S., Nielsen, R. O., Nazemipour, M., Jewell, N. P., Altman, D. G., & Campbell, M. J. (2021) · British Journal of Sports Medicine · doi:10.1136/bjsports-2020-103652 · Cited by 263
Self-citationAznar, L. A. M., Ral, P. C., Anta, R. M. O., Martín, J. J. D., Baladia, E., Basulto, J., Serrat, S. B., Altaba, I. I., López-Sobaler, A. M., Manera, M., et al. (2013) · PubMed · doi:10.3305/nutrhosp.v28in06.6691 · Cited by 267
Chuang, M. L., Hibberd, M. G., Salton, C. J., Beaudin, R. A., Riley, M. F., Parker, R. A., Douglas, P. S., & Manning, W. J. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00551-3 · Cited by 272
Echocardiographic assessment of cardiac function in diabetic db/db and transgenic db/db-hGLUT4 mice
Semeniuk, L. M., Kryski, A. J., & Severson, D. L. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00088.2002 · Cited by 266
Nussbaumer, S., Leunig, M., Glatthorn, J. F., Stauffacher, S., Gerber, H., & Maffiuletti, N. A. (2010) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-11-194 · Cited by 262
Qiao, Y., Steinman, D. A., Qin, Q., Etesami, M., Schär, M., Astor, B. C., & Wasserman, B. A. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22592 · Cited by 267
Gaemperli, O., Shalhoub, J., Owen, D. R. J., Lamare, F., Johansson, S., Fouladi, N., Davies, A. H., Rimoldi, O. E., & Camici, P. G. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr367 · Cited by 267
Hypercapnic acidosis and mortality in acute lung injury*
Kregenow, D. A., Rubenfeld, G. D., Hudson, L. D., & Swenson, E. R. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000194533.75481.03 · Cited by 266
Respiratory impedance in healthy subjects: baseline values and bronchodilator response
Oostveen, E., Boda, K., van der Grinten, C. P. M., James, A. L., Young, S., Nieland, H., & Hantos, Z. (2013) · European Respiratory Journal · doi:10.1183/09031936.00126212 · Cited by 262
Bosy-Westphal, A., Later, W., Hitze, B., Sato, T., Kossel, E., Glüer, C.-C., Heller, M., & Müller, M. J. (2008) · Obesity Facts · doi:10.1159/000176061 · Cited by 263
Kowallick, J. T., Kutty, S., Edelmann, F., Chiribiri, A., Villa, A., Steinmetz, M., Sohns, J. M., Staab, W., Bettencourt, N., Unterberg-Buchwald, C., et al. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-014-0060-6 · Cited by 264
Agreement Between 35 Published Frailty Scores in the General Population
Aguayo, G. A., Donneau, A.-F., Vaillant, M. T., Schritz, A., Franco, O. H., Stranges, S., Malisoux, L., Guillaume, M., & Witte, D. R. (2017) · American Journal of Epidemiology · doi:10.1093/aje/kwx061 · Cited by 264
Lewis, G. F., Furman, S. A., McCool, M. F., & Porges, S. W. (2012) · Biological Psychology · doi:10.1016/j.biopsycho.2011.11.009 · Cited by 264
How Sensitive to Clinical Change are ETDRS logMAR Visual Acuity Measurements?
Rosser, D. A., Cousens, S. N., Murdoch, I. E., Fitzke, F. W., & Laidlaw, D. A. H. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-1100 · Cited by 264
Post, B., Merkus, M. P., de Bie, R. M. A., de Haan, R. J., & Speelman, J. D. (2005) · Movement Disorders · doi:10.1002/mds.20640 · Cited by 266
España-Romero, V., Ortega, F. B., Vicente-Rodríguez, G., Artero, E. G., Rey, J. P., & Ruiz, J. R. (2010) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3181b296a5 · Cited by 265
Zeiner, A., Holzer, M., Sterz, F., Behringer, W., Schörkhuber, W., Müllner, M., Frass, M., Siostrzonek, P., Ratheiser, K., Kaff, A., et al. (2000) · Stroke · doi:10.1161/01.str.31.1.86 · Cited by 267
Delgado, V., Tops, L. F., van Bommel, R. J., van der Kley, F., Marsan, N. A., Klautz, R. J., Versteegh, M. I. M., Holman, E. R., Schalij, M. J., & Bax, J. J. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp351 · Cited by 260
A Critical Review of Ultra-Short-Term Heart Rate Variability Norms Research
Shaffer, F., Meehan, Z. M., & Zerr, C. L. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.594880 · Cited by 248
Relationship Between Airway Obstruction and Respiratory Symptoms in Adult Asthmatics
Teeter, J. G., & Bleecker, E. R. (1998) · Chest · doi:10.1378/chest.113.2.272 · Cited by 266
Hallan, S., Åsberg, A., Lindberg, M., & Johnsen, H. (2004) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2004.03.027 · Cited by 266
Transcutaneous Bilirubin Measurement: A Multicenter Evaluation of a New Device
Rubaltelli, F. F., Gourley, G. R., Loskamp, N., Modi, N., Roth-Kleiner, M., Sender, A., & Vert, P. (2001) · Pediatrics · doi:10.1542/peds.107.6.1264 · Cited by 264
Psychometric properties of vision‐related quality of life questionnaires: a systematic review
De Boer, M. R., Moll, A. C., De Vet, H. C. W., Terwee, C. B., Völker‐Dieben, H. J. M., & Van Rens, G. H. M. B. (2004) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2004.00187.x · Cited by 263
Validity and reliability of the revised convergence insufficiency symptom survey in adults
Rouse, M. W., Borsting, E. J., Lynn Mitchell, G., Scheiman, M., Cotter, S. A., Cooper, J., Kulp, M. T., London, R., Wensveen, J., & Convergence Insufficiency Treatment Trial Group (2004) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2004.00202.x · Cited by 251
Role of Variability in Explaining Ethanol Pharmacokinetics: Research and Forensic Applications
Norberg, ?., Jones, A. W., Hahn, R. G., & Gabrielsson, J. L. (2003) · Clinical Pharmacokinetics · doi:10.2165/00003088-200342010-00001 · Cited by 265
Clinical examination is an inaccurate predictor of intraabdominal pressure
Sugrue, M., Bauman, A., Jones, F., Bishop, G., Flabouris, A., Parr, M., Stewart, A., Hillman, K., & Deane, S. A. (2002) · World Journal of Surgery · doi:10.1007/s00268-002-6411-8 · Cited by 264
Sievänen, H., Koskue, V., Rauhio, A., Kannus, P., Heinonen, A., & Vuori, I. (1998) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1998.13.5.871 · Cited by 266
El Fakhri, G., Kardan, A., Sitek, A., Dorbala, S., Abi-Hatem, N., Lahoud, Y., Fischman, A., Coughlan, M., Yasuda, T., & Di Carli, M. F. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.104.007831 · Cited by 266
Comparing Methods of Clinical Measurement: Reporting Standards for Bland and Altman Analysis
Mantha, S., Roizen, M. F., Fleisher, L. A., Thisted, R., & Foss, J. (2000) · Anesthesia & Analgesia · doi:10.1097/00000539-200003000-00018 · Cited by 266
Besson, H., Brage, S., Jakes, R. W., Ekelund, U., & Wareham, N. J. (2010) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.2009.28432 · Cited by 264
The origin of intermuscular adipose tissue and its pathophysiological implications
Vettor, R., Milan, G., Franzin, C., Sanna, M., De Coppi, P., Rizzuto, R., & Federspil, G. (2009) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00229.2009 · Cited by 261
Facial expressions of pain in cats: the development and validation of a Feline Grimace Scale
Evangelista, M. C., Watanabe, R., Leung, V. S. Y., Monteiro, B. P., O’Toole, E., Pang, D. S. J., & Steagall, P. V. (2019) · Scientific Reports · doi:10.1038/s41598-019-55693-8 · Cited by 242
Heymsfield, S. B., Gallagher, D., Kotler, D. P., Wang, Z., Allison, D. B., & Heshka, S. (2002) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.2002.282.1.e132 · Cited by 262
Shape of the Retinal Surface in Emmetropia and Myopia
Atchison, D. A., Pritchard, N., Schmid, K. L., Scott, D. H., Jones, C. E., & Pope, J. M. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-1506 · Cited by 267
Validation of the Spanish Version of the Roland-Morris Questionnaire
Kovacs, F. M., Llobera, J., Gil del Real, M. T., Abraira, V., Gestoso, M., & Fernández, C. (2002) · Spine · doi:10.1097/00007632-200203010-00016 · Cited by 263
Kurtz, T. W., Griffin, K. A., Bidani, A. K., Davisson, R. L., & Hall, J. E. (2005) · Hypertension · doi:10.1161/01.hyp.0000150857.39919.cb · Cited by 263
de Zambotti, M., Goldstein, C., Cook, J., Menghini, L., Altini, M., Cheng, P., & Robillard, R. (2024) · SLEEP · doi:10.1093/sleep/zsad325 · Cited by 250
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.