STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 601–700 of 47,868
Interobserver agreement issues in radiology
Benchoufi, M., Matzner-Lober, E., Molinari, N., Jannot, A.-S., & Soyer, P. (2020) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2020.09.001 · Cited by 317
George, R. T., Arbab-Zadeh, A., Miller, J. M., Kitagawa, K., Chang, H.-J., Bluemke, D. A., Becker, L., Yousuf, O., Texter, J., Lardo, A. C., et al. (2009) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.108.813766 · Cited by 324
Laxity in healthy and osteoarthritic knees
Sharma, L., Lou, C., Felson, D. T., Dunlop, D. D., Kirwan-Mellis, G., Hayes, K. W., Weinrach, D., & Buchanan, T. S. (1999) · Arthritis & Rheumatism · doi:10.1002/1529-0131(199905)42:5<861::aid-anr4>3.0.co;2-n · Cited by 287
Benedetti, T. R. B., Antunes, P. D. C., Rodriguez-Añez, C. R., Mazo, G. Z., & Petroski, É. L. (2007) · Revista Brasileira de Medicina do Esporte · doi:10.1590/s1517-86922007000100004 · Cited by 221
Dewey, M., Zimmermann, E., Deissenrieder, F., Laule, M., Dübel, H.-P., Schlattmann, P., Knebel, F., Rutsch, W., & Hamm, B. (2009) · Circulation · doi:10.1161/circulationaha.109.859280 · Cited by 328
Denton, C. P., Cailes, J. B., Phillips, G. D., Wells, A. U., Black, C. M., & Bois, R. M. (1997) · Rheumatology · doi:10.1093/rheumatology/36.2.239 · Cited by 323
Malm, S., Frigstad, S., Sagberg, E., Larsson, H., & Skjaerpe, T. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.05.068 · Cited by 323
Determination of Polyethylene Wear in Total Hip Replacements with Use of Digital Radiographs*
Martell, J. M., & Berdia, S. (1997) · The Journal of Bone and Joint Surgery (American Volume) · doi:10.2106/00004623-199711000-00004 · Cited by 321
Critical Review of Generic and Dermatology-Specific Health-Related Quality of Life Instruments
Both, H., Essink-Bot, M.-L., Busschbach, J., & Nijsten, T. (2007) · Journal of Investigative Dermatology · doi:10.1038/sj.jid.5701142 · Cited by 327
Faster permutation inference in brain imaging
Winkler, A. M., Ridgway, G. R., Douaud, G., Nichols, T. E., & Smith, S. M. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.05.068 · Cited by 329
Quantitative Doppler assessment of valvular regurgitation.
Enriquez-Sarano, M., Bailey, K. R., Seward, J. B., Tajik, A. J., Krohn, M. J., & Mays, J. M. (1993) · Circulation · doi:10.1161/01.cir.87.3.841 · Cited by 325
Dougados, M., Nguyen, M., Berdah, L., Mazi�res, B., Vignon, E., Lequesne, M., & for the ECHODIAH Investigators Study Group (2001) · Arthritis & Rheumatism · doi:10.1002/1529-0131(200111)44:11<2539::aid-art434>3.0.co;2-t · Cited by 321
Effects of a ginger extract on knee pain in patients with osteoarthritis
Altman, R. D., & Marcussen, K. C. (2001) · Arthritis & Rheumatism · doi:10.1002/1529-0131(200111)44:11<2531::aid-art433>3.0.co;2-j · Cited by 507
Rossille, D., Gressier, M., Damotte, D., Maucort-Boulch, D., Pangault, C., Semana, G., Le Gouill, S., Haioun, C., Tarte, K., Lamy, T., et al. (2014) · Leukemia · doi:10.1038/leu.2014.137 · Cited by 322
Technical note: Validation of a system for monitoring rumination in dairy cows
Schirmann, K., von Keyserlingk, M. A. G., Weary, D. M., Veira, D. M., & Heuwieser, W. (2009) · Journal of Dairy Science · doi:10.3168/jds.2009-2361 · Cited by 315
Perkins, B. A., Nelson, R. G., Ostrander, B. E. P., Blouch, K. L., Krolewski, A. S., Myers, B. D., & Warram, J. H. (2005) · Journal of the American Society of Nephrology · doi:10.1681/asn.2004100854 · Cited by 323
ZERBIB, F., BRULEY DES VARANNES, S., ROMAN, S., POUDEROUX, P., ARTIGUE, F., CHAPUT, U., MION, F., CAILLOL, F., VERIN, E., BOMMELAER, G., et al. (2005) · Alimentary Pharmacology & Therapeutics · doi:10.1111/j.1365-2036.2005.02677.x · Cited by 331
A simple method for measuring force, velocity and power output during squat jump
Samozino, P., Morin, J.-B., Hintzy, F., & Belli, A. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.07.028 · Cited by 307
DXA scanning in clinical practice
El Maghraoui, A., & Roux, C. (2008) · QJM · doi:10.1093/qjmed/hcn022 · Cited by 323
Nevill, A. M., & Atkinson, G. (1997) · British Journal of Sports Medicine · doi:10.1136/bjsm.31.4.314 · Cited by 317
Zhao, Z., Möller, K., Steinmann, D., Frerichs, I., & Guttmann, J. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1589-y · Cited by 321
Ebrahim, S. (1995) · Social Science & Medicine · doi:10.1016/0277-9536(95)00116-o · Cited by 321
An Overview on Assessing Agreement with Continuous Measurements
Barnhart, H. X., Haber, M. J., & Lin, L. I. (2007) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400701376480 · Cited by 319
The repeatability of measurement of the ocular components.
Zadnik, K., Mutti, D. O., & Adams, A. J. (1992) · PubMed · Cited by 373
Fayad, Z. A., Nahar, T., Fallon, J. T., Goldman, M., Aguinaldo, J. G., Badimon, J. J., Shinnar, M., Chesebro, J. H., & Fuster, V. (2000) · Circulation · doi:10.1161/01.cir.101.21.2503 · Cited by 322
Tixier, F., Hatt, M., Le Rest, C. C., Le Pogam, A., Corcos, L., & Visvikis, D. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.099127 · Cited by 318
Dietary Choline Intake: Current State of Knowledge Across the Life Cycle
Wiedeman, A., Barr, S., Green, T., Xu, Z., Innis, S., & Kitts, D. (2018) · Nutrients · doi:10.3390/nu10101513 · Cited by 316
Hemoglobin concentration of high-altitude Tibetans and Bolivian Aymara
Beall, C. M., Brittenham, G. M., Strohl, K. P., Blangero, J., Williams-Blangero, S., Goldstein, M. C., Decker, M. J., Vargas, E., Villena, M., Soria, R., et al. (1998) · American Journal of Physical Anthropology · doi:10.1002/(sici)1096-8644(199807)106:3<385::aid-ajpa10>3.0.co;2-x · Cited by 318
In vivo validation of whole body composition estimates from dual-energy X-ray absorptiometry
Prior, B. M., Cureton, K. J., Modlesky, C. M., Evans, E. M., Sloniger, M. A., Saunders, M., & Lewis, R. D. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.2.623 · Cited by 317
Hypoxemia and Arterial Hypotension at the Accident Scene in Head Injury
Stocchetti, N., Furlan, A., & Volta, F. (1996) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-199605000-00014 · Cited by 328
Effect of 1-year smoking cessation on airway inflammation in COPD and asymptomatic smokers
Willemse, B. W. M., ten Hacken, N. H. T., Rutgers, B., Lesman-Leegte, I. G. A. T., Postma, D. S., & Timens, W. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00108904 · Cited by 322
Krosshaug, T., Steffen, K., Kristianslund, E., Nilstad, A., Mok, K.-M., Myklebust, G., Andersen, T. E., Holme, I., Engebretsen, L., & Bahr, R. (2016) · The American Journal of Sports Medicine · doi:10.1177/0363546515625048 · Cited by 313
The German version of the Oral Health Impact Profile – translation and psychometric properties
John, M. T., Patrick, D. L., & Slade, G. D. (2002) · European Journal of Oral Sciences · doi:10.1034/j.1600-0722.2002.21363.x · Cited by 316
Physical Activity in Preschoolers: Understanding Prevalence and Measurement Issues
Oliver, M., Schofield, G. M., & Kolt, G. S. (2007) · Sports Medicine · doi:10.2165/00007256-200737120-00004 · Cited by 315
Reliability and Intensity of the Six-Minute Walk Test in Healthy Elderly Subjects
KERVIO, G., CARRE, F., & VILLE, N. S. (2003) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200301000-00025 · Cited by 317
Brunner, H. I., Silverman, E. D., To, T., Bombardier, C., & Feldman, B. M. (2002) · Arthritis & Rheumatism · doi:10.1002/art.10072 · Cited by 319
The reliability of the 1RM strength test for untrained middle-aged individuals
Levinger, I., Goodman, C., Hare, D. L., Jerums, G., Toia, D., & Selig, S. (2009) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2007.10.007 · Cited by 315
Biochemistry and Clinical Role of Human Cystatin C
Mussap, M., & Plebani, M. (2004) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408360490504934 · Cited by 313
Determination of the transcript profile of human endometrium
Borthwick, J. M. (2003) · Molecular Human Reproduction · doi:10.1093/molehr/gag004 · Cited by 318
Baumgartner, H., Stefenelli, T., Niederberger, J., Schima, H., & Maurer, G. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00066-2 · Cited by 316
Goligher, E. C., Laghi, F., Detsky, M. E., Farias, P., Murray, A., Brace, D., Brochard, L. J., Bolz, S.-S., Rubenfeld, G. D., Kavanagh, B. P., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3724-2 · Cited by 315
Ambulatory measurement of 3D knee joint angle
Favre, J., Jolles, B. M., Aissaoui, R., & Aminian, K. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.12.003 · Cited by 316
Edwards, J. D., Houtrow, A. J., Vasilevskis, E. E., Rehm, R. S., Markovitz, B. P., Graham, R. J., & Dudley, R. A. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e31824e68cf · Cited by 313
Castarlenas, E., Jensen, M. P., von Baeyer, C. L., & Miró, J. (2017) · The Clinical Journal of Pain · doi:10.1097/ajp.0000000000000406 · Cited by 311
McCollough, C. H., Bartley, A. C., Carter, R. E., Chen, B., Drees, T. A., Edwards, P., Holmes, D. R., Huang, A. E., Khan, F., Leng, S., et al. (2017) · Medical Physics · doi:10.1002/mp.12345 · Cited by 308
Finney, H., Newman, D. J., Gruber, W., Merle, P., & Price, C. P. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.6.1016 · Cited by 318
Sander, A. P., Hajer, N. M., Hemenway, K., & Miller, A. C. (2002) · Physical Therapy · doi:10.1093/ptj/82.12.1201 · Cited by 317
Comparison of Echocardiographic Indices Used to Predict Fluid Responsiveness in Ventilated Patients
Vignon, P., Repessé, X., Bégot, E., Léger, J., Jacob, C., Bouferrache, K., Slama, M., Prat, G., & Vieillard-Baron, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201604-0844oc · Cited by 308
Optoelectronic Plethysmography in Intensive Care Patients
ALIVERTI, A., DELLACÁ, R., PELOSI, P., CHIUMELLO, D., PEDOTTI, A., & GATTINONI, L. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.5.9903024 · Cited by 315
Diurnal pattern of QTc interval: How long is prolonged?
Molnar, J., Zhang, F., Weiss, J., Ehlert, F. A., & Rosenthal, J. E. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00426-2 · Cited by 312
Reliability, Validity, and Responsiveness of Four Knee Outcome Scales for Athletic Patients
Marx, R. G., Jones, E. C., Allen, A. A., Altchek, D. W., OʼBrien, S. J., Rodeo, S. A., Williams, R. J., Warren, R. F., & Wickiewicz, T. L. (2001) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200110000-00001 · Cited by 316
Yamakoshi, G. (1998) · American Journal of Physical Anthropology · doi:10.1002/(sici)1096-8644(199807)106:3<311::aid-ajpa4>3.0.co;2-p · Cited by 249
Nishiyama, K. K., Macdonald, H. M., Buie, H. R., Hanley, D. A., & Boyd, S. K. (2010) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.091020 · Cited by 313
Issues for selection of outcome measures in stroke rehabilitation: ICF Participation
Salter, K., Jutai, J., Teasell, R., Foley, N., BItensky, J., & Bayley, M. (2005) · Disability and Rehabilitation · doi:10.1080/0963828040008552 · Cited by 313
Magnetic resonance imaging of total body fat
Thomas, E. L., Saeed, N., Hajnal, J. V., Brynes, A., Goldstone, A. P., Frost, G., & Bell, J. D. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.5.1778 · Cited by 313
Nelson, B. W., & Allen, N. B. (2019) · JMIR mHealth and uHealth · doi:10.2196/10828 · Cited by 310
Reliability, validity, and responsiveness of the six-minute walk test in patients with heart failure
Demers, C., McKelvie, R. S., Negassa, A., & Yusuf, S. (2001) · American Heart Journal · doi:10.1067/mhj.2001.118468 · Cited by 312
Heat pain thresholds: normative data and repeatability
Yarnitsky, D., Sprecher, E., Zaslansky, R., & Hemli, J. A. (1995) · Pain · doi:10.1016/0304-3959(94)00132-x · Cited by 313
Martin, H. J., Yule, V., Syddall, H. E., Dennison, E. M., Cooper, C., & Aihie Sayer, A. (2006) · Gerontology · doi:10.1159/000091824 · Cited by 309
Smidt, N., van der Windt, D. A., Assendelft, W. J., Mourits, A. J., Devillé, W. L., de Winter, A. F., & Bouter, L. M. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2002.33728 · Cited by 304
Reliability of the Actigraph GT3X+ Accelerometer in Adults under Free-Living Conditions
Aadland, E., & Ylvisåker, E. (2015) · PLOS ONE · doi:10.1371/journal.pone.0134606 · Cited by 313
Zaman, A. G., Archbold, R. A., Helft, G., Paul, E. A., Curzen, N. P., & Mills, P. G. (2000) · Circulation · doi:10.1161/01.cir.101.12.1403 · Cited by 314
LACKNER, B., SCHMIDINGER, G., PIEH, S., FUNOVICS, M. A., & SKORPIK, C. (2005) · Optometry and Vision Science · doi:10.1097/01.opx.0000180817.46312.0a · Cited by 311
A longitudinal study of cardiac output in normal human pregnancy
Mabie, W. C., DiSessa, T. G., Crocker, L. G., Sibai, B. M., & Arheart, K. L. (1994) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(94)70297-7 · Cited by 310
Development and Validation of a Grading System for the Quality of Cost-Effectiveness Studies
Chiou, C.-F., Hay, J. W., Wallace, J. F., Bloom, B. S., Neumann, P. J., Sullivan, S. D., Yu, H.-T., Keeler, E. B., Henning, J. M., & Ofman, J. J. (2003) · Medical Care · doi:10.1097/00005650-200301000-00007 · Cited by 311
Rothenfluh, D. A., Mueller, D. A., Rothenfluh, E., & Min, K. (2015) · European Spine Journal · doi:10.1007/s00586-014-3454-0 · Cited by 308
Ainslie, P. N., Reilly, T., & Westerterp, K. R. (2003) · Sports Medicine · doi:10.2165/00007256-200333090-00004 · Cited by 309
The reliability of short-term measurements of heart rate variability
Sandercock, G. R. H., Bromley, P. D., & Brodie, D. A. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2004.09.013 · Cited by 307
Validation of bioanalytical chromatographic methods
Hartmann, C., Smeyers-Verbeke, J., Massart, D. L., & McDowall, R. D. (1998) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/s0731-7085(97)00198-2 · Cited by 308
A New Method For Bronchial-provocation Testing in Asthmatic Subjects Using a Dry Powder of Mannitol
ANDERSON, S. D., BRANNAN, J., SPRING, J., SPALDING, N., RODWELL, L. T., CHAN, K., GONDA, I., WALSH, A., & CLARK, A. R. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.156.3.9701113 · Cited by 312
Kumeda, Y., Inaba, M., Goto, H., Nagata, M., Henmi, Y., Furumitsu, Y., Ishimura, E., Inui, K., Yutani, Y., Miki, T., et al. (2002) · Arthritis & Rheumatism · doi:10.1002/art.10269 · Cited by 313
Borsting, E. J., ROUSE, M. W., Mitchell, G. L., Scheiman, M. M., Cotter, S. A., Cooper, J., Kulp, M. T., London, R., & The Convergence Insufficiency Treatment Trial Group (2003) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2003.tb01751.x · Cited by 301
Sample Size for Assessing Agreement between Two Methods of Measurement by Bland−Altman Method
Lu, M.-J., Zhong, W.-H., Liu, Y.-X., Miao, H.-Z., Li, Y.-C., & Ji, M.-H. (2016) · The International Journal of Biostatistics · doi:10.1515/ijb-2015-0039 · Cited by 306
Zwanenburg, A. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04391-8 · Cited by 306
Collie, A., Maruff, P., Makdissi, M., McCrory, P., McStephen, M., & Darby, D. (2003) · Clinical Journal of Sport Medicine · doi:10.1097/00042752-200301000-00006 · Cited by 305
Heart rate and performance parameters in elite cyclists: a longitudinal study.
LUC??A, A., HOYOS, J., P??REZ, M., & CHICHARRO, J. L. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200010000-00018 · Cited by 304
Predicting the Crohnʼs disease activity index from the harvey-bradshaw index
Best, W. R. (2006) · Inflammatory Bowel Diseases · doi:10.1097/01.mib.0000215091.77492.2a · Cited by 306
Beerbaum, P., Körperich, H., Barth, P., Esdorn, H., Gieseke, J., & Meyer, H. (2001) · Circulation · doi:10.1161/01.cir.103.20.2476 · Cited by 309
Ocular Rigidity in Living Human Eyes
Pallikaris, I. G., Kymionis, G. D., Ginis, H. S., Kounis, G. A., & Tsilimbaris, M. K. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0162 · Cited by 301
Brage, S., Ekelund, U., Brage, N., Hennings, M. A., Froberg, K., Franks, P. W., & Wareham, N. J. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00092.2006 · Cited by 303
Reliability of echocardiographic assessment of left ventricular structure and function
Palmieri, V., Dahlöf, B., DeQuattro, V., Sharpe, N., Bella, J. N., de Simone, G., Paranicas, M., Fishman, D., & Devereux, R. B. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00396-4 · Cited by 302
Performance Evaluation of the MiniMed® Continuous Glucose Monitoring System During Patient Home Use
Gross, T. M., Bode, B. W., Einhorn, D., Kayne, D. M., Reed, J. H., White, N. H., & Mastrototaro, J. J. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/152091500316737 · Cited by 303
Thermal testing: normative data and repeatability for various test algorithms
Yarnitsky, D., & Sprecher, E. (1994) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(94)90239-9 · Cited by 308
Zaki, R., Bulgiba, A., Ismail, R., & Ismail, N. A. (2012) · PLoS ONE · doi:10.1371/journal.pone.0037908 · Cited by 293
Evaluation of an electronic cowside test to detect subclinical ketosis in dairy cows
Iwersen, M., Falkenberg, U., Voigtsberger, R., Forderung, D., & Heuwieser, W. (2009) · Journal of Dairy Science · doi:10.3168/jds.2008-1795 · Cited by 302
Sampson, D. M., Gong, P., An, D., Menghini, M., Hansen, A., Mackey, D. A., Sampson, D. D., & Chen, F. K. (2017) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.17-21551 · Cited by 298
Reprodutibilidade e validade do Questionário Internacional de Atividade Física em adolescentes
Guedes, D. P., Lopes, C. C., & Guedes, J. E. R. P. (2005) · Revista Brasileira de Medicina do Esporte · doi:10.1590/s1517-86922005000200011 · Cited by 306
Miller, K. K., Rosner, W., Lee, H., Hier, J., Sesmilo, G., Schoenfeld, D., Neubauer, G., & Klibanski, A. (2004) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-030680 · Cited by 301
Design, Analysis, and Interpretation of Method-Comparison Studies
Hanneman, S. K. (2008) · AACN Advanced Critical Care · doi:10.1097/01.aacn.0000318125.41512.a3 · Cited by 306
Koppenhaver, S. L., Hebert, J. J., Fritz, J. M., Parent, E. C., Teyhen, D. S., & Magel, J. S. (2009) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2008.06.022 · Cited by 300
Conducting correlation analysis: important limitations and pitfalls
Janse, R. J., Hoekstra, T., Jager, K. J., Zoccali, C., Tripepi, G., Dekker, F. W., & van Diepen, M. (2021) · Clinical Kidney Journal · doi:10.1093/ckj/sfab085 · Cited by 255
Torriani, F. J., Komarow, L., Parker, R. A., Cotter, B. R., Currier, J. S., Dubé, M. P., Fichtenbaum, C. J., Gerschenson, M., Mitchell, C. K. C., Murphy, R. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.04.049 · Cited by 300
Ellis, K. J., Yao, M., Shypailo, R. J., Urlando, A., Wong, W. W., & Heird, W. C. (2007) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/85.1.90 · Cited by 299
Inertial Sensor-Based Stride Parameter Calculation From Gait Sequences in Geriatric Patients
Rampp, A., Barth, J., Schuelein, S., Gassmann, K.-G., Klucken, J., & Eskofier, B. M. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2368211 · Cited by 303
Dyer, R. A., Reed, A. R., van Dyk, D., Arcache, M. J., Hodges, O., Lombard, C. J., Greenwood, J., & James, M. F. (2009) · Anesthesiology · doi:10.1097/aln.0b013e3181b437e0 · Cited by 296
Is Podocyte Injury Relevant in Diabetic Nephropathy?
Dalla Vestra, M., Masiero, A., Roiter, A. M., Saller, A., Crepaldi, G., & Fioretto, P. (2003) · Diabetes · doi:10.2337/diabetes.52.4.1031 · Cited by 301
Nagy, S., Jansen, J., Topper, E. K., & Gadella, B. M. (2003) · Biology of Reproduction · doi:10.1095/biolreprod.102.011445 · Cited by 297
International Journal of Collaborative Research on Internal Medicine & Public Health
Valdivia, J. R. M. (2021) · Journal of Womens Health Issues and Care · Cited by 300
Barkana, Y., Gerber, Y., Elbaz, U., Schwartz, S., Ken-Dror, G., Avni, I., & Zadok, D. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2005.03.058 · Cited by 298
Swartz, J. E., Pothen, A. J., Wegner, I., Smid, E. J., Swart, K. M. A., de Bree, R., Leenen, L. P. H., & Grolman, W. (2016) · Oral Oncology · doi:10.1016/j.oraloncology.2016.09.006 · Cited by 302
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.