The DOI matches its Crossref record; 52 of the 53 references it cites were found in a registry or an index.
A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Abstract
The feasibility of implanting an array of penetrating electrodes into peripheral nerves is studied in acute experiments in the cat sciatic nerve. A novel, silicon-based array of microelectrodes, the Utah Electrode Array, was used, which contains 25 or 100 1-mm long electrodes that project out from a silicon substrate. Electrode arrays of this complexity, when inserted in the peripheral nerve, could cause significant compression of the nerve and block the conduction of action potentials. Using a high velocity insertion technique, the electrode array was implanted into the sciatic nerve. Compound action potentials were evoked by and recorded with cuff electrodes. Compound action potentials recorded 1 h after insertion were only slightly altered from those recorded before insertion. Single units were readily extracted from evoked multiunit neural recordings in response to cutaneous stimulation and limb rotation around joints. Current injections into the nerve through the electrodes evoked muscle twitches with currents in the 10 microA range. Recording and stimulation stability were demonstrated for periods of up to 60 h. We have shown that high density arrays of electrodes can be inserted into the peripheral nerve and can provide a stable recording and stimulating interface to individual peripheral nerve axons. Such an array may be useful in future neuroscience research and potential neuroprosthetic applications.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Electrodes in the array were capable of selectively recording single-unit responses from mechanoreceptors, although only in 10-20% of the electrodes, and evoked graded recruitment of force in muscle groups in a highly selective fashion with current injections in the 1-20 m A range (Branner and Norman, 2000; Branner et al., 2001) .”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Branner and Norman, 2000
In the citing paper
“We have shown that the production of a defined geometric surface area (GSA) of the electrode tips was possible using either an oxygen plasma etching technique [1,21] or by excimer laser ablation [22].”
From A new high-density (25 electrodes/mm2) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures (2013) · cites this paper as [1]
In the citing paper
“Currently, there is one high electrode-density (6.25 electrodes/mm 2 ), high electrodecount (96 electrodes) penetrating device available for neuromodulation of large structures (> 4 mm) in the peripheral nervous system [1].”
From A new high-density (25 electrodes/mm2) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures (2013) · cites this paper as [1]
In the citing paper
“The electrode proportions, impedances, number of functionally distinct electrodes and SNR of HD-USEAs are comparable to the conventionally spaced Utah electrode arrays [1,13].”
From A new high-density (25 electrodes/mm2) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures (2013) · cites this paper as [1]
In the citing paper
“The conventionally spaced, lower density USEA can be implanted both acutely (<1 days) [1] and chronically (>6 months) [40,41] with insult to the epineurium or perinerium limited to the areas penetrated by the microelectrodes.”
From A new high-density (25 electrodes/mm2) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures (2013) · cites this paper as [1]
In the citing paper
“Moreover, there was little compression of the nerve fibers around the tips and shanks of the HD-USEA electrodes, as had been previously noted for the conventionally spaced USEAs [1].”
From A new high-density (25 electrodes/mm2) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures (2013) · cites this paper as [1]
Citations
Cites
Somatosensory, proprioceptive, and sympathetic activity in human peripheral nerves
Vallbo, A. B., Hagbarth, K. E., Torebjork, H. E., & Wallin, B. G. (1979) · Physiological Reviews · doi:10.1152/physrev.1979.59.4.919 · Cited by 1,507
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
Self-citationMaynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
Self-citationSingle unit recording capabilities of a 100 microelectrode array
Nordhausen, C. T., Maynard, E. M., & Normann, R. A. (1996) · Brain Research · doi:10.1016/0006-8993(96)00321-6 · Cited by 358
Self-citationA glass/silicon composite intracortical electrode array
Jones, K. E., Campbell, P. K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368134 · Cited by 354
Self-citationAFFERENT IMPULSES IN CUTANEOUS SENSORY NERVES IN HUMAN SUBJECTS
Hensel, H., & Boman, K. (1960) · Journal of Neurophysiology · doi:10.1152/jn.1960.23.5.564 · Cited by 323
Selective control of muscle activation with a multipolar nerve cuff electrode
Veraart, C., Grill, W. M., & Mortimer, J. T. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237694 · Cited by 320
A method for pneumatically inserting an array of penetrating electrodes into cortical tissue
Rousche, P. J., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368133 · Cited by 305
Self-citationCuff electrodes for chronic stimulation and recording of peripheral nerve activity
Loeb, G. E., & Peck, R. A. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00123-9 · Cited by 215
Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
Yoshida, K., & Horch, K. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.243412 · Cited by 208
Research works printed but not linked: 1
- Branner, 1996, A 20 channel peripheral nerve interface, Soc. Neurosci. Abstr., 22, 668
Cited by
Sorted by citations
Items 101–200 of 234
Srinivasan, A., Tipton, J., Tahilramani, M., Kharbouch, A., Gaupp, E. A., Song, C. L., Venkataraman, P., Falcone, J., Lacour, S. P., Stanley, G. B., et al. (2015) · European Journal of Neuroscience · doi:10.1111/ejn.13080 · Cited by 21
Langlois, P. J., Demosthenous, A., Pachnis, I., & Donaldson, N. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2034138 · Cited by 20
Ultra-low noise miniaturized neural amplifier with hardware averaging
Dweiri, Y. M., Eggers, T. E., McCallum, G. A., & Durand, D. M. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/046024 · Cited by 20
Hysteretic behavior of bladder afferent neurons in response to changes in bladder pressure
Ross, S. E., Sperry, Z. J., Mahar, C., & Bruns, T. M. (2016) · BMC Neuroscience · doi:10.1186/s12868-016-0292-5 · Cited by 20
Chronic sensory-motor activity in behaving animals using regenerative multi-electrode interfaces,
Desai, V. H., Anand, S., Tran, M., Kanneganti, A., Vasudevan, S., Seifert, J. L., Cheng, J., Keefer, E. W., & Romero-Ortega, M. I. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6944000 · Cited by 19
Charkhkar, H., Christie, B. P., Pinault, G. J., Tyler, D. J., & Triolo, R. J. (2019) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108414 · Cited by 19
Selective and Graded Recruitment of Cat Hamstring Muscles With Intrafascicular Stimulation
Dowden, B. R., Wilder, A. M., Hiatt, S. D., Normann, R. A., Brown, N. A. T., & Clark, G. A. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2011988 · Cited by 19
Self-citationAdvances in the use of electrical stimulation for the recovery of motor function
Popović, D. B., & Popović, M. B. (2011) · Progress in brain research · doi:10.1016/b978-0-444-53815-4.00005-4 · Cited by 18
Recent progress of electroactive interface in neural engineering
Shan, Y., Cui, X. J., Chen, X., & Li, Z. (2022) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1827 · Cited by 19
Mechanical considerations for design and implementation of peripheral intraneural devices
Stiller, A. M., González‐González, M. A., Boothby, J. M., Sherman, S., Benavides, J., Romero‐Ortega, M. I., Pancrazio, J. J., & Black, B. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab4114 · Cited by 17
Model-based Bayesian signal extraction algorithm for peripheral nerves
Eggers, T. E., Dweiri, Y. M., McCallum, G. A., & Durand, D. M. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7d94 · Cited by 17
Peripheral neurostimulation for encoding artificial somatosensations
Valle, G. (2022) · European Journal of Neuroscience · doi:10.1111/ejn.15822 · Cited by 17
Automated Stimulus-Response Mapping of High-Electrode-Count Neural Implants
Wilder, A. M., Hiatt, S. D., Dowden, B. R., Brown, N. A. T., Normann, R. A., & Clark, G. A. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2029494 · Cited by 16
Self-citationYu, X. P., Su, J., Guo, J. Y., Zhang, X., Li, R. H., Chai, X., Chen, Y., Zhang, D. G., Wang, J., Sui, X., et al. (2019) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108450 · Cited by 16
Sensory information feedback for neural prostheses
Weber, D. J., Hao, M., Urbin, M. A., Schoenewald, C., & Lan, N. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816034-3.00021-3 · Cited by 16
Extraction of motor activity from the cervical spinal cord of behaving rats
Prasad, A., & Şahin, M. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/005 · Cited by 16
Limb movements generated by stimulating muscle, nerve and spinal cord.
Stein, R. B., Aoyagi, Y., Mushahwar, V. K., & Procházka, A. (2002) · PubMed · Cited by 16
Electrode Arrays for Detecting and Modulating Deep Brain Neural Information in Primates: A Review
Zhang, S., Song, Y., Lv, S., Jing, L., Wang, M., Liu, Y., Xu, W., Jiao, P., Zhang, S., Wang, M., et al. (2025) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0249 · Cited by 16
Normann, R. A., McDonnall, D., Clark, G. A., Stein, R. B., & Branner, A. (2006) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2005.1556422 · Cited by 15
Self-citationPERIPHERAL NERVE RECORDING ELECTRODES AND TECHNIQUES
Yoshida, K., & Riso, R. (2004) · Series on bioengineering and biomedical engineering · doi:10.1142/9789812561763_0021 · Cited by 15
On the development of optical peripheral nerve interfaces
Anderson, H., & Weir, R. F. (2019) · Neural Regeneration Research · doi:10.4103/1673-5374.245461 · Cited by 14
Li, L.-J., Zhang, J., Zhang, F., Lineaweaver, W. C., Chen, T.-Y., & Chen, Z.-W. (2005) · Microsurgery · doi:10.1002/micr.20159 · Cited by 14
Failure Modes of Implanted Neural Interfaces
Delbeke, J., Haesler, S., & Prodanov, D. (2020) · Springer eBooks · doi:10.1007/978-3-030-41854-0_6 · Cited by 16
On linking human and machine brains
Warwick, K., & Ruiz, V. F. (2008) · Neurocomputing · doi:10.1016/j.neucom.2007.06.017 · Cited by 13
A High-Yield Fabrication Process for Silicon Neural Probes
Oh, S., Song, J. K., Kim, J., & Kim, S. J. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.862568 · Cited by 13
Kim, J.-H., Baek, D.-H., Kim, D. H., & Park, D. (2022) · Current Applied Physics · doi:10.1016/j.cap.2022.05.001 · Cited by 12
Wark, H. A. C., Dowden, B. R., Cartwright, P. C., & Normann, R. A. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2174490 · Cited by 12
Self-citationAnderson, H. E., Fontaine, A. K., Caldwell, J. H., & Weir, R. F. F. (2018) · Scientific Reports · doi:10.1038/s41598-018-21528-1 · Cited by 13
Selzer, M. E., Clarke, S., Cohen, L. G., Kwakkel, G., & Miller, R. H. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9780511995590.012 · Cited by 12
Population Coding of Forelimb Joint Kinematics by Peripheral Afferents in Monkeys
Umeda, T., Seki, K., Sato, M.-A., Nishimura, Y., Kawato, M., & Isa, T. (2012) · PLoS ONE · doi:10.1371/journal.pone.0047749 · Cited by 12
A Microclip Peripheral Nerve Interface (μcPNI) for Bioelectronic Interfacing with Small Nerves
Rowan, C. C., Graudejus, O., & Otchy, T. M. (2021) · Advanced Science · doi:10.1002/advs.202102945 · Cited by 11
From calcium imaging to graph topology
Blevins, A. S., Bassett, D. S., Scott, E. K., & Vanwalleghem, G. C. (2022) · Network Neuroscience · doi:10.1162/netn_a_00262 · Cited by 11
Cheng, C., Kmech, J., Mushahwar, V. K., & Elias, A. L. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2241061 · Cited by 11
Improved long‐term recording of nerve signal by modified intrafascicular electrodes in rabbits
Jia, X., Zhen, G., Püttgen, H. A., Zhang, J., & Chen, T. (2008) · Microsurgery · doi:10.1002/micr.20475 · Cited by 10
Qiao, S., Torkamani‐Azar, M., Salama, P., & Yoshida, K. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056014 · Cited by 10
Design of electrodes for stimulation and recording
Howell, B. L., & Grill, W. M. (2015) · Elsevier eBooks · doi:10.1016/b978-1-78242-101-6.00004-5 · Cited by 9
Blind source separation of neural recordings and control signals
Tesfayesus, W., & Durand, D. M. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260400 · Cited by 9
Qiao, S., Stieglitz, T., & Yoshida, K. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2489924 · Cited by 8
Zhou, R., Jiang, N., Englehart, K. B., & Parker, P. A. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0555-8 · Cited by 8
Frederick, R. A., Troyk, P. R., & Cogan, S. F. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac2bb8 · Cited by 7
Lee, S. L., Kim, M. N., Lee, J. H., Lim, H.-G., & Cho, J. (2015) · Journal of Korea Multimedia Society · doi:10.9717/kmms.2015.18.5.652 · Cited by 7
PDMS microchannel regenerative peripheral nerve interface
Musick, K. M., Chew, D. J., Fawcett, J. W., & Lacour, S. P. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6696018 · Cited by 7
Control of Skeletal Muscle Force with Currents Injected Via an Intrafascicular, Microelectrode Array
Normann, R. A., McDonnall, D., & Clark, G. A. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616282 · Cited by 7
Self-citationKAGAN, Z. B., RamRakhyani, A. K., Khan, F., Lazzi, G., Normann, R. A., & Warren, D. J. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944148 · Cited by 7
Self-citationW:Ti Flexible Transversal Electrode Array for Peripheral Nerve Stimulation: A Feasibility Study
Silveira, C. R. A., Brunton, E., Escobedo‐Cousin, E., Gupta, G., Whittaker, R. G., O'Neill, A. G., & Nazarpour, K. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3014812 · Cited by 7
Connecting residual nervous system and prosthetic legs for sensorimotor and cognitive rehabilitation
Valle, G., Preatoni, G., & Raspopović, S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00007-1 · Cited by 8
Delbeke, J., & Veraart, C. (2006) · Wiley eBooks · doi:10.1002/0471732877.emd325 · Cited by 7
Inductive sensing technique for low power implantable hydrogel-based biochemcial sensors
Yu, Y., Bhola, V., Tathireddy, P., Young, D. J., & Roundy, S. (2015) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2015.7370640 · Cited by 6
A handheld device for magnetically inserting a neural interface into a peripheral nervous system
Yim, S., Hwang, D., Ihn, Y. S., Jeong, J., Oh, S.-R., & Kim, K. (2017) · 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8036803 · Cited by 5
Bending Properties of Materials for Peripheral Nerve Interfaces
Woods, J. E., Welle, E. J., Chen, L., Richie, J. M., Patel, P. R., & Chestek, C. A. (2020) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems50311.2020.9265629 · Cited by 5
Schiefer, M. A., Tyler, D. J., & Triolo, R. J. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091011 · Cited by 5
The Promise and Threat of Modern Cybernetics
Warwick, K. (2007) · Southern Medical Journal · doi:10.1097/smj.0b013e31802e6653 · Cited by 5
Yoshida, K., Kurstjens, M., Citi, L., Koch, K. P., & Micera, S. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428525 · Cited by 5
Preliminary results of a handheld nerve electrode insertion device
Yim, S., Oh, Y.-E., Choi, W., Park, H., Jeong, J., Ihn, Y., Hwang, D., Oh, S.-R., Kim, J., & Kim, K. (2018) · 2018 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2018.8460882 · Cited by 4
Fabrication of Biomedical Electrodes Using Printing Approaches
Rajbhandari, G., Nattestad, A., Liu, X., Beirne, S., & Wallace, G. G. (2024) · Biomedical Materials & Devices · doi:10.1007/s44174-024-00176-2 · Cited by 4
The auditory nerve implant—concept and device description of a novel electrical auditory prosthesis
Lenarz, T., Solzbacher, F., Rieth, L. W., Leber, M., Adams, M. E., Salcher, R. B., Warren, D. J., Oxenham, A. J., Dyballa, K.-H., Samii, A., et al. (2025) · Bioelectronic Medicine · doi:10.1186/s42234-025-00188-3 · Cited by 4
Electrical interfaces for recording, stimulation, and sensing
Hess‐Dunning, A., & Zorman, C. A. (2015) · Elsevier eBooks · doi:10.1016/b978-0-323-26208-8.00002-9 · Cited by 4
Handheld Nerve Electrode Insertion Tool
Yim, S., Oh, Y.-E., Jeong, J., Ihn, Y. S., Hwang, D., Oh, S., & Kim, K. (2018) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2018.2864978 · Cited by 4
Towards a high precision robotic platform for neural interface implantation
Jeong, J., Yim, S., Hwang, D., Oh, S., Kim, K., & Ihn, Y. S. (2018) · IEEE International Conference on Cyborg and Bionic Systems (CBS) · doi:10.1109/cbs.2018.8612253 · Cited by 4
Therapeutic potential of computer to cerebral cortex implantable devices
Warwick, K., Gasson, M. N., & Spiers, A. J. (2007) · Springer eBooks · doi:10.1007/978-3-211-33081-4_61 · Cited by 4
A novel implantable multichannel silicon-based microelectrode
Xiao-Hong, S., Ruoxin, Z., Wei-Hua, P., & Hong-Da, C. (2007) · Chinese Physics · doi:10.1088/1009-1963/16/7/053 · Cited by 4
Bioelectric interfaces for the peripheral nervous system
Yoshida, K., Stieglitz, T., & Qiao, S. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944815 · Cited by 4
Plasma etched carbon microelectrode arrays for bioelectrical measurements
Heikkinen, J. J., Kaarela, T., Ludwig, A., Sukhanova, T., Khakipoor, S., Kim, S. I., Han, J. G., Huttunen, H. J., Rivera, C., Lauri, S. E., et al. (2018) · Diamond and Related Materials · doi:10.1016/j.diamond.2018.09.024 · Cited by 4
CLINICAL IMPLEMENTATION OF NERVE CUFF ELECTRODES FOR AN UPPER EXTREMITY NEUROPROSTHESIS
Polasek, K. H. (2007) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 4
Ziat, M., & Bensmaı̈a, S. J. (2015) · Elsevier eBooks · doi:10.1016/b978-0-08-097086-8.55057-0 · Cited by 4
Wu, Y., & Guo, L. (2020) · Neural Interface Engineering · doi:10.1007/978-3-030-41854-0_5 · Cited by 3
Valle, G., Carpaneto, J., & Micera, S. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_27 · Cited by 3
Introduction and fundamental requirements of neuroprostheses
Kilgore, K. L. (2015) · Elsevier eBooks · doi:10.1016/b978-1-78242-101-6.00001-x · Cited by 3
Schiefer, M. A. (2009) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 3
Procházka, A., & Mushahwar, V. K. (2004) · Series on bioengineering and biomedical engineering · doi:10.1142/9789812561763_0024 · Cited by 3
Sharpened and mechanically durable carbon fiber electrode arrays for neural interfacingPreprint
Welle, E. J., Woods, J. E., Jiman, A. A., Richie, J. M., Bottorff, E. C., Ouyang, Z., Seymour, J. P., Patel, P. R., Bruns, T. M., & Chestek, C. A. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.01.21.427697 · Cited by 3
Sinkjær, T., Yoshida, K., Jensen, W., & Schnabel, V. (2006) · Wiley eBooks · doi:10.1002/0471732877.emd098 · Cited by 3
Cavalcanti, L. M., Thomas, W., Warren, D. J., & Mathews, V. J. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3530924 · Cited by 2
Klus, J., Boys, A. J., Serrano, R. R., Malliaras, G. G., & Carnicer‐Lombarte, A. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae0c3b · Cited by 2
High-fidelity interfacing for bionic rehabilitation
Vujaklija, I. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-23987-8.00003-1 · Cited by 2
Zhou, Z., Hu, Z., & Lyu, H. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adb5c4 · Cited by 2
Wireless Bioelectronic Devices Driven by Deep Red Light
Jakešová, M. (2021) · Linköping studies in science and technology. Dissertations · doi:10.3384/diss.diva-171846 · Cited by 2
Gozzi, N., & Valle, G. (2023) · Elsevier eBooks · doi:10.1016/b978-0-443-18498-7.00014-4 · Cited by 2
Madden, L. R., Graham, R. D., Lempka, S. F., & Bruns, T. M. (2024) · Journal of Neurophysiology · doi:10.1152/jn.00385.2023 · Cited by 2
Neurostimulation in Neuro-Ophthalmology: Mechanisms and Therapeutic Potential
Shaheen, N., Khaled, M. B., Seo, S., Bezchlibnyk, Y. B., Flouty, O. E., & Bharmauria, V. (2024) · IntechOpen eBooks · doi:10.5772/intechopen.115105 · Cited by 4
Conjugated Polymers for Neural Interfaces : Prospects, possibilities and future challenges
Asplund, M. (2009) · Cited by 2
Braeken, D., & Prodanov, D. (2010) · InTech eBooks · doi:10.5772/7613 · Cited by 2
Humayun, M. S., Lakhanpal, R. R., & Weiland, J. D. (2006) · Elsevier eBooks · doi:10.1016/b978-0-323-02598-0.50160-9 · Cited by 2
Bioelectronics and Neural Interfaces
Tong, W., Robles, U. A. A., & Gelmi, A. A. (2021) · Royal Society of Chemistry eBooks · doi:10.1039/9781788019828-00180 · Cited by 2
Selectivity of the TIME Implantable Nerve Electrode
Badía, J., Harreby, K. R., Kundu, A., Boretius, T., Stieglitz, T., Jensen, W., & Navarro, X. (2022) · River Publishers eBooks · doi:10.1201/9781003337973-7 · Cited by 2
Evaluation of Time-Domain Features of Sensory ENG Signals
Silveira, C. R. A., Brunton, E., Khushaba, R. N., & Nazarpour, K. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512798 · Cited by 2
Neural electrodes for long-term tissue interfaces
del Valle, J., Rodríguez‐Meana, B., & Navarro, X. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00009-5 · Cited by 2
NOVEL PROCESSING ROUTES FOR NEURAL INTERFACES
Barrett, R. C. (2014) · University of Birmingham Institutional Research Archive (University of Birmingham) · doi:10.13140/2.1.1683.2647 · Cited by 2
Warwick, K., & Gasson, M. N. (2008) · Lecture notes in computer science · doi:10.1007/978-3-540-89430-8_1 · Cited by 2
Wallace, P. G. G., Moulton, S. E., Kapsa, R. M., & Higgins, M. J. (2012) · Wiley eBooks · doi:10.1002/9783527646029.ch1 · Cited by 2
Design of Electrodes for Efficient and Selective Electrical Stimulation of Nervous Tissue
Howell, B. L. (2015) · DukeSpace (Duke University) · Cited by 2
Zhou, Z., Hu, Z., & Lyu, H. (2024) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas58744.2024.10558305 · Cited by 1
Nguyen, C. K., Sturgill, B. S., Srikanthan, B., Dousti, B., Bhatt, M., Khajehzadeh, M., Mangarolia, S., Hasan, N., Hernandez-Reynoso, A. G., Negi, S., et al. (2026) · Frontiers in Neuroscience · doi:10.3389/fnins.2026.1789112 · Cited by 2
Selective stimulation of peripheral motor nerve using a flexible split-ring electrode
Lee, S., Sheshadri, S., Xue, N., Sun, T., Lee, C., Thakor, N. V., Yen, S., & Delgado-Martínez, I. (2015) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2015.7146657 · Cited by 1
Hybrid Brains – Biology, Technology Merger
Warwick, K. (2008) · Communications in computer and information science · doi:10.1007/978-3-540-92219-3_2 · Cited by 1
Proprioceptive information coded by populational sensory afferents
Umeda, T., Isa, T., & Nishimura, Y. (2014) · The Journal of Physical Fitness and Sports Medicine · doi:10.7600/jpfsm.3.477 · Cited by 1
Overstreet, C. K. (2013) · Cited by 1
Useche, S., & Andrés, C. (2016) · UTA ResearchCommons (University of Texas Arlington) · Cited by 1
Silveira, C. R. A., Brunton, E., Spendiff, S., & Nazarpour, K. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512751 · Cited by 1
Wang, R., Yu, H., & Li, Z. (2017) · Toxinology · doi:10.1007/978-981-10-2798-7_41-1 · Cited by 2
Metadata
- Authors
- Branner, A., & Normann, R. A.
- Affiliations
- University of Utah (US)
- Corresponding author
- Normann, Richard Alan
- Venue
- Brain Research Bulletin
- Publisher
- Elsevier BV
- Published
- 2000-03
- Volume
- 51
- Issue
- 4
- Pages
- 293-306
- ISSN
- 0361-9230 (ISSN-L)
- OpenAlex
- W1970923678
- Semantic Scholar
- 99213097ea1e1f7e51940a5e1ab0673dd53a0f0c
- Cited by
- 234
- References
- 53
- Citations by year
- 2026: 1 · 2025: 7 · 2024: 7 · 2023: 5 · 2022: 10 · 2021: 9 · 2020: 8 · 2019: 10 · 2018: 13 · 2017: 10 · 2016: 10 · 2015: 18 · 2014: 17 · 2013: 8 · 2012: 15
- FWCI
- 1.03
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Brain Research Bulletin (publishedVersion)
- PubMed (publishedVersion)
- Funders
- University of Alberta
- Deutscher Akademischer Austauschdienst
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Keywords
- Utah electrode array, microelectrode arrays, sciatic nerve, peripheral nerve recording, peripheral nerve stimulation, nerve compression, compound action potential, single-unit recording, multi-unit recording, muscle twitch, neuroprosthetics
- MeSH terms
- Action Potentials, Animals, Cats, Electric Stimulation, Microelectrodes, Muscle Contraction, Sciatic Nerve, Muscle, Skeletal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review