The DOI matches its Crossref record; 52 of the 53 references it cites were found in a registry or an index.
A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Abstract
The feasibility of implanting an array of penetrating electrodes into peripheral nerves is studied in acute experiments in the cat sciatic nerve. A novel, silicon-based array of microelectrodes, the Utah Electrode Array, was used, which contains 25 or 100 1-mm long electrodes that project out from a silicon substrate. Electrode arrays of this complexity, when inserted in the peripheral nerve, could cause significant compression of the nerve and block the conduction of action potentials. Using a high velocity insertion technique, the electrode array was implanted into the sciatic nerve. Compound action potentials were evoked by and recorded with cuff electrodes. Compound action potentials recorded 1 h after insertion were only slightly altered from those recorded before insertion. Single units were readily extracted from evoked multiunit neural recordings in response to cutaneous stimulation and limb rotation around joints. Current injections into the nerve through the electrodes evoked muscle twitches with currents in the 10 microA range. Recording and stimulation stability were demonstrated for periods of up to 60 h. We have shown that high density arrays of electrodes can be inserted into the peripheral nerve and can provide a stable recording and stimulating interface to individual peripheral nerve axons. Such an array may be useful in future neuroscience research and potential neuroprosthetic applications.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Electrodes in the array were capable of selectively recording single-unit responses from mechanoreceptors, although only in 10-20% of the electrodes, and evoked graded recruitment of force in muscle groups in a highly selective fashion with current injections in the 1-20 m A range (Branner and Norman, 2000; Branner et al., 2001) .”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Branner and Norman, 2000
In the citing paper
“We have shown that the production of a defined geometric surface area (GSA) of the electrode tips was possible using either an oxygen plasma etching technique [1,21] or by excimer laser ablation [22].”
From A new high-density (25 electrodes/mm2) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures (2013) · cites this paper as [1]
In the citing paper
“Currently, there is one high electrode-density (6.25 electrodes/mm 2 ), high electrodecount (96 electrodes) penetrating device available for neuromodulation of large structures (> 4 mm) in the peripheral nervous system [1].”
From A new high-density (25 electrodes/mm2) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures (2013) · cites this paper as [1]
In the citing paper
“The electrode proportions, impedances, number of functionally distinct electrodes and SNR of HD-USEAs are comparable to the conventionally spaced Utah electrode arrays [1,13].”
From A new high-density (25 electrodes/mm2) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures (2013) · cites this paper as [1]
In the citing paper
“The conventionally spaced, lower density USEA can be implanted both acutely (<1 days) [1] and chronically (>6 months) [40,41] with insult to the epineurium or perinerium limited to the areas penetrated by the microelectrodes.”
From A new high-density (25 electrodes/mm2) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures (2013) · cites this paper as [1]
In the citing paper
“Moreover, there was little compression of the nerve fibers around the tips and shanks of the HD-USEA electrodes, as had been previously noted for the conventionally spaced USEAs [1].”
From A new high-density (25 electrodes/mm2) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures (2013) · cites this paper as [1]
Citations
Cites
Somatosensory, proprioceptive, and sympathetic activity in human peripheral nerves
Vallbo, A. B., Hagbarth, K. E., Torebjork, H. E., & Wallin, B. G. (1979) · Physiological Reviews · doi:10.1152/physrev.1979.59.4.919 · Cited by 1,507
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
Self-citationMaynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
Self-citationSingle unit recording capabilities of a 100 microelectrode array
Nordhausen, C. T., Maynard, E. M., & Normann, R. A. (1996) · Brain Research · doi:10.1016/0006-8993(96)00321-6 · Cited by 358
Self-citationA glass/silicon composite intracortical electrode array
Jones, K. E., Campbell, P. K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368134 · Cited by 354
Self-citationAFFERENT IMPULSES IN CUTANEOUS SENSORY NERVES IN HUMAN SUBJECTS
Hensel, H., & Boman, K. (1960) · Journal of Neurophysiology · doi:10.1152/jn.1960.23.5.564 · Cited by 323
Selective control of muscle activation with a multipolar nerve cuff electrode
Veraart, C., Grill, W. M., & Mortimer, J. T. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237694 · Cited by 320
A method for pneumatically inserting an array of penetrating electrodes into cortical tissue
Rousche, P. J., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368133 · Cited by 305
Self-citationCuff electrodes for chronic stimulation and recording of peripheral nerve activity
Loeb, G. E., & Peck, R. A. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00123-9 · Cited by 215
Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
Yoshida, K., & Horch, K. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.243412 · Cited by 208
Research works printed but not linked: 1
- Branner, 1996, A 20 channel peripheral nerve interface, Soc. Neurosci. Abstr., 22, 668
Cited by
Sorted by citations
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454
“Utah arrays were developed in the early 1990s as a means to deploy large numbers of electrodes to deep layers of the brain (Normann and Fernandez, 2016), and have since been adapted for use in nerves (Branner and Normann, 2000; Branner et al., 2001).”
BackgroundSuner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.857687 · Cited by 415
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Selective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 359
Self-citationLong-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301
Self-citationEffective parameters for stimulation of dissociated cultures using multi-electrode arrays
Wagenaar, D. A., Pine, J., & Potter, S. M. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.03.005 · Cited by 309
Prasad, A., Xue, Q.-S., Sankar, V., Nishida, T., Shaw, G., Streit, W. J., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056015 · Cited by 298
Real-time multi-channel stimulus artifact suppression by local curve fitting
Wagenaar, D. A., & Potter, S. M. (2002) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00149-8 · Cited by 224
The application of implant technology for cybernetic systems
Warwick, K., Gasson, M., Hutt, B., Goodhew, I., Kyberd, P., Andrews, B., Teddy, P., & Shad, A. (2003) · Archives of Neurology · doi:10.1001/archneur.60.10.1369 · Cited by 206
Negi, S., Bhandari, R., Rieth, L. W., & Solzbacher, F. (2010) · Biomedical Materials · doi:10.1088/1748-6041/5/1/015007 · Cited by 209
Schultz, A. E., & Kuiken, T. A. (2011) · PM&R · doi:10.1016/j.pmrj.2010.06.016 · Cited by 186
Dhillon, G. S., Krüger, T. B., Sandhu, J. S., & Horch, K. W. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00937.2004 · Cited by 183
Lago, N., Ceballos, D., J Rodrı́guez, F., Stieglitz, T., & Navarro, X. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.025 · Cited by 178
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175
Technology Insight: future neuroprosthetic therapies for disorders of the nervous system
Normann, R. A. (2007) · Nature Clinical Practice Neurology · doi:10.1038/ncpneuro0556 · Cited by 170
Self-citationPulsed laser versus electrical energy for peripheral nerve stimulation
Wells, J. D., Konrad, P. E., Kao, C., Jansen, D., & Mahadevan-Jansen, A. M. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.016 · Cited by 156
Wark, H. A. C., Sharma, R., Mathews, K. S., Fernandez, E., Yoo, J., Christensen, B., Tresco, P., Rieth, L., Solzbacher, F., Normann, R. A., et al. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/045003 · Cited by 148
Self-citationFlexible Electrodes for Brain–Computer Interface System
Wang, J., Wang, T., Liu, H., Wang, K., Kumi, M., Feng, Z., Li, P., & Huang, W. (2023) · Advanced Materials · doi:10.1002/adma.202211012 · Cited by 142
The foreign body response to the Utah Slant Electrode Array in the cat sciatic nerve
Christensen, M. B., Pearce, S. M., Ledbetter, N. M., Warren, D. J., Clark, G. A., & Tresco, P. A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.010 · Cited by 135
Clinical applications of penetrating neural interfaces and Utah Electrode Array technologies
Normann, R. A., & Fernandez, E. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/061003 · Cited by 135
Self-citationA review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Selective stimulation of the human femoral nerve with a flat interface nerve electrode
Schiefer, M. A., Polasek, K. H., Triolo, R. J., Pinault, G. C. J., & Tyler, D. J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026006 · Cited by 130
Wang, J., He, T., & Lee, C. (2019) · Nano Energy · doi:10.1016/j.nanoen.2019.104039 · Cited by 129
Emerging Soft Conductors for Bioelectronic Interfaces
Gao, D., Parida, K., & Lee, P. S. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201907184 · Cited by 131
Maynard, E. M. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.145 · Cited by 126
Automatic spike detection based on adaptive template matching for extracellular neural recordings
Kim, S., & McNames, J. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.05.033 · Cited by 124
Micera, S., Navarro, X., Carpaneto, J., Citi, L., Tonet, O., Rossini, P. M., Carrozza, M. C., Hoffmann, K. P., Vivo, M., Yoshida, K., et al. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2006207 · Cited by 120
Jhaveri, S. J., Hynd, M. R., Dowell‐Mesfin, N., Turner, J. N., Shain, W. G., & Ober, C. K. (2008) · Biomacromolecules · doi:10.1021/bm801101e · Cited by 120
Zhang, D., Peng, Y., Qi, H., Gao, Q., & Zhang, C. (2008) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2008.11.010 · Cited by 115
Chen, Y., Lai, H.-Y., Lin, S.-H., Chao, W.-H., Chao, W.-H., Liao, C., Tsang, S., Chen, Y., & Lin, S.-Y. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.05.010 · Cited by 110
Lawrence, S. M., Dhillon, G. S., Jensen, W., Yoshida, K., & Horch, K. W. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.831491 · Cited by 106
Yoo, P. B., & Durand, D. M. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851482 · Cited by 106
Interfaces with the Peripheral Nerve for the Control of Neuroprostheses
del Valle, J., & Navarro, X. (2013) · International Review of Neurobiology · doi:10.1016/b978-0-12-420045-6.00002-x · Cited by 105
Badia, J., Boretius, T., Pascual-Font, A., Udina, E., Stieglitz, T., & Navarro, X. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2153850 · Cited by 103
Neural machine interfaces for controlling multifunctional powered upper-limb prostheses
Ohnishi, K., Weir, R. F. F., & Kuiken, T. (2006) · Expert Review of Medical Devices · doi:10.1586/17434440.4.1.43 · Cited by 103
Miniaturized optogenetic neural implants: a review
Fan, B., & Li, W. (2015) · Lab on a Chip · doi:10.1039/c5lc00588d · Cited by 99
Topographical distribution of motor fascicles in the sciatic‐tibial nerve of the rat
Badia, J., Pascual‐Font, A., Vivó, M., Udina, E., & Navarro, X. (2010) · Muscle & Nerve · doi:10.1002/mus.21652 · Cited by 98
McDonnall, D., Clark, G. A., & Normann, R. A. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.828425 · Cited by 98
Self-citationTissue-engineered peripheral nerve interfaces
Spearman, B. S., Desai, V. H., Mobini, S., McDermott, M. D., Graham, J. B., Otto, K. J., Judy, J. W., & Schmidt, C. E. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701713 · Cited by 96
Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics
Rijnbeek, E. H., Eleveld, N., & Olthuis, W. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00350 · Cited by 91
“One way to describe the signal quality is the signal-to-noise ratio as has been done by multiple studies (Branner and Normann, 2000; Yoo and Durand, 2005; Citi et al., 2011; Srinivasan et al., 2015; Dweiri et al., 2017; Lee et al., 2017).”
Artificial vision through neuronal stimulation
Fernandes, R. A. B., Diniz, B., Ribeiro, R., & Humayun, M. (2012) · Neuroscience Letters · doi:10.1016/j.neulet.2012.01.063 · Cited by 90
Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review.
Ghafoor, U., Kim, S., & Hong, K.-S. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00059 · Cited by 88
“Over the past 70 years, peripheral nerve interfaces enabling the restoration of sensorimotor functions have been improving and evolving (Branner and Normann, 2000).”
Lai, H., Liao, L., Lin, C., Hsu, J.-H., He, X., Chen, Y., Chang, J.-Y., Chen, H.-F., Tsang, S., & Shih, Y. I. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/3/036001 · Cited by 83
The Motor Cortex and Its Role in Phantom Limb Phenomena
Reilly, K. T., & Sirigu, A. (2007) · The Neuroscientist · doi:10.1177/1073858407309466 · Cited by 83
The Evolution of Neuroprosthetic Interfaces
Adewole, D. O., Serruya, M. D., Harris, J. P., Burrell, J. C., Petrov, D., Chen, H.-C. I., Wolf, J. A., & Cullen, D. K. (2016) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2016017198 · Cited by 86
Irwin, Z. T., Schroeder, K. E., Vu, P. P., Tat, D. M., Bullard, A. J., Woo, S. L., Sando, I. C., Urbanchek, M. G., Cederna, P. S., & Chestek, C. A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046007 · Cited by 78
Microchannels as Axonal Amplifiers
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.909533 · Cited by 76
Long Micro-Channel Electrode Arrays: A Novel Type of Regenerative Peripheral Nerve Interface
Lacour, S. P., Fitzgerald, J. J., Lago, N., Tarte, E., McMahon, S., & Fawcett, J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2031241 · Cited by 75
FitzGerald, J. J., Lago, N., Benmerah, S., Serra, J., Watling, C. P., Cameron, R. E., Tarte, E., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/016010 · Cited by 73
Spatial and temporal variability in response to hybrid electro-optical stimulation
Duke, A. R., Lu, H., Jenkins, M. W., Chiel, H. J., & Jansen, D. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/3/036003 · Cited by 71
Jia, X., Koenig, M. A., Zhang, X., Zhang, J., Chen, T., & Chen, Z. (2007) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2007.02.021 · Cited by 70
Intrafascicular stimulation of monkey arm nerves evokes coordinated grasp and sensory responses
Ledbetter, N. M., Ethier, C., Oby, E. R., Hiatt, S. D., Wilder, A. M., Ko, J. H., Agnew, S. P., Miller, L. E., & Clark, G. A. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00688.2011 · Cited by 69
Aoyagi, Y., Stein, R. B., Branner, A., Pearson, K. G., & Normann, R. A. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(03)00143-2 · Cited by 68
Self-citationMicrochannel-based regenerative scaffold for chronic peripheral nerve interfacing in amputees
Srinivasan, A., Tahilramani, M., Bentley, J. T., Gore, R. K., Millard, D. C., Mukhatyar, V. J., Joseph, A., Haque, A. S., Stanley, G. B., English, A. W., et al. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.11.035 · Cited by 67
Badia, J., Raspopovic, S., Carpaneto, J., Micera, S., & Navarro, X. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2440768 · Cited by 65
Zhang, S., Song, Y., Wang, M., Zhang, Z., Fan, X., Song, X., Zhuang, P., Yue, F., Chan, P., & Cai, X. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.04.087 · Cited by 64
Real-time control of walking using recordings from dorsal root ganglia
Holinski, B. J., Everaert, D. G., Mushahwar, V. K., & Stein, R. B. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056008 · Cited by 58
PERIPHERAL NERVE AND MUSCLE STIMULATION
Mortimer, J. T., & Bhadra, N. (2004) · Series on bioengineering and biomedical engineering · doi:10.1142/9789812561763_0020 · Cited by 61
de la Oliva, N., Navarro, X., & del Valle, J. (2017) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.36274 · Cited by 58
A Review: Research Progress of Neural Probes for Brain Research and Brain–Computer Interface
Luo, J., Xue, N., & Chen, J. (2022) · Biosensors · doi:10.3390/bios12121167 · Cited by 63
A Parylene Self-Locking Cuff Electrode for Peripheral Nerve Stimulation and Recording
Yu, H., Xiong, W., Zhang, H., Wang, W., & Li, Z. (2014) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2333733 · Cited by 56
Schiefer, M. A., Tyler, D. J., & Triolo, R. J. (2012) · Journal of Computational Neuroscience · doi:10.1007/s10827-011-0381-5 · Cited by 53
Selective motor unit recruitment via intrafascicular multielectrode stimulation
McDonnall, D., Clark, G. A., & Normann, R. A. (2004) · Canadian Journal of Physiology and Pharmacology · doi:10.1139/y04-047 · Cited by 53
Self-citationYoshida, K., Farina, D., Akay, M., & Jensen, W. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2038613 · Cited by 53
Material considerations for peripheral nerve interfacing
Kim, Y.-T., & Romero-Ortega, M. I. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.99 · Cited by 47
Ackermann, D. M., Foldes, E. L., Bhadra, N., & Kilgore, K. L. (2009) · Muscle & Nerve · doi:10.1002/mus.21496 · Cited by 48
Li, L., Cao, P., Sun, M., Chai, X., Wu, K., Xu, X., Li, X., & Ren, Q. (2008) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-008-0977-2 · Cited by 46
Microchannel Electrodes for Recording and Stimulation: In Vitro Evaluation
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2013960 · Cited by 45
Biomechanical and functional variation in rat sciatic nerve following cuff electrode implantation
Restaino, S. M., Abliz, E., Wachrathit, K., Krauthamer, V., & Shah, S. B. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-73 · Cited by 44
Chronic histological effects of the flat interface nerve electrode
Leventhal, D. K., Cohen, M., & Durand, D. M. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/2/004 · Cited by 43
Cobo, A., Larson, C. E., Scholten, K., Miranda, J. A., Elyahoodayan, S., Song, D. B., Pikov, V., & Meng, E. F. (2018) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2018.2881908 · Cited by 43
Selective neural activation in a histologically derived model of peripheral nerve
Butson, C. R., Miller, I., Normann, R. A., & Clark, G. A. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036009 · Cited by 46
Self-citationThota, A. K., Kuntaegowdanahalli, S., Starosciak, A. K., Abbas, J. J., Orbay, J., Horch, K. W., & Jung, R. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.07.020 · Cited by 41
Blind source separation of peripheral nerve recordings
Tesfayesus, W., & Durand, D. M. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/s03 · Cited by 40
Chen, Z., Zhang, T., Chen, C., Yang, S., Lv, Z., Cao, L., Ren, J., Shao, Z., Jiang, L., & Ling, S. (2022) · Materials Horizons · doi:10.1039/d2mh00296e · Cited by 38
Normann, R. A., Dowden, B. R., Frankel, M. A., Wilder, A. M., Hiatt, S. D., Ledbetter, N. M., Warren, D. A., & Clark, G. A. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026019 · Cited by 37
Self-citationVasudevan, S., Patel, K., & Welle, C. G. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2552/14/1/016008 · Cited by 38
Toward Nontransient Silk Bioelectronics: Engineering Silk Fibroin for Bionic Links
Patil, A. C., Xiong, Z., & Thakor, N. V. (2020) · Small Methods · doi:10.1002/smtd.202000274 · Cited by 37
Research Progress on the Flexibility of an Implantable Neural Microelectrode
Zhao, H., Liu, R., Zhang, H., Cao, P., Liu, Z., & Li, Y. (2022) · Micromachines · doi:10.3390/mi13030386 · Cited by 37
Neural electrodes for brain‐computer interface system: From rigid to soft
Yang, D., Tian, G., Chen, J., Liu, Y., Fatima, E., Qiu, J., Malek, N. A. N. N., & Qi, D. (2025) · BMEMat · doi:10.1002/bmm2.12130 · Cited by 37
Printable microscale interfaces for long-term peripheral nerve mapping and precision control
Otchy, T. M., Michas, C., Lee, B., Gopalan, K., Nerurkar, V., Gleick, J., Semu, D., Darkwa, L., Holinski, B. J., Chew, D. J., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18032-4 · Cited by 35
Flexible epineural strip electrode for recording in fine nerves
Lee, S., Yen, S.-C., Sheshadri, S., Martinez, I. D., Xue, N., Xiang, Z., Thakor, N. V., & Lee, C. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2466442 · Cited by 33
Intraspinal Microstimulation using Cylindrical Multielectrodes
Snow, S., Horch, K. W., & Mushahwar, V. K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.857638 · Cited by 33
Mast Cells and Nerve Signal Conduction in Acupuncture
Yin, N., Yang, H., Yao, W., Xia, Y., & Ding, G. (2018) · Evidence-based Complementary and Alternative Medicine · doi:10.1155/2018/3524279 · Cited by 32
Influence of nerve cuff channel count and implantation site on the separability of afferent ENG
Silveira, C. R. A., Brunton, E., Spendiff, S., & Nazarpour, K. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aabca0 · Cited by 29
Bionic Intrafascicular Interfaces for Recording and Stimulating Peripheral Nerve Fibers
Jung, R., Abbas, J. J., Kuntaegowdanahalli, S. S., & Thota, A. K. (2017) · Bioelectronics in Medicine · doi:10.2217/bem-2017-0009 · Cited by 30
Mathews, K. S., Wark, H. A. C., & Normann, R. A. (2014) · Muscle & Nerve · doi:10.1002/mus.24171 · Cited by 26
Self-citationRodrigues, F., Ribeiro, J. F., Anacleto, P., Fouchard, A., Olivier David, A., Sarro, P. M., & Mendes, P. M. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab4dbb · Cited by 25
Sato, T., Suzuki, T., & Mabuchi, K. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.08.009 · Cited by 25
Varying-Length Polymer Microneedle Arrays Fabricated by Droplet Backside Exposure
Kwon, K. Y., Weber, A., & Li, W. (2014) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2352412 · Cited by 23
Liquid metal neuro-electrical interface
Zhang, X., Liu, C., Tang, R., Feng, W., Gao, J., Wu, B., Deng, Z., Liu, J., & Li, L. (2024) · Soft Science · doi:10.20517/ss.2023.58 · Cited by 23
Mohamed, O., Al–Othman, A., Al-Nashash, H. A., Tawalbeh, M., AlMomani, F. A., & Rezakazemi, M. (2021) · Chemosphere · doi:10.1016/j.chemosphere.2021.129680 · Cited by 23
Prosthetic Stimulation of the Auditory System with Intraneural Electrodes
Arts, H. A., Jones, D. A., & Anderson, D. J. (2003) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/00034894031120s905 · Cited by 22
Biomechanical Characterization of Needle Piercing Into Peripheral Nervous Tissue
Sergi, P. N., Carrozza, M. C., Dario, P., & Micera, S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.879463 · Cited by 22
Zheng, X., Zhang, J., Chen, T., & Chen, Z. (2003) · Microsurgery · doi:10.1002/micr.10116 · Cited by 23
RamRakhyani, A. K., KAGAN, Z. B., Warren, D. J., Normann, R. A., & Lazzi, G. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2446761 · Cited by 21
Self-citation
Metadata
- Authors
- Branner, A., & Normann, R. A.
- Affiliations
- University of Utah (US)
- Corresponding author
- Normann, Richard Alan
- Venue
- Brain Research Bulletin
- Publisher
- Elsevier BV
- Published
- 2000-03
- Volume
- 51
- Issue
- 4
- Pages
- 293-306
- ISSN
- 0361-9230 (ISSN-L)
- OpenAlex
- W1970923678
- Semantic Scholar
- 99213097ea1e1f7e51940a5e1ab0673dd53a0f0c
- Cited by
- 234
- References
- 53
- Citations by year
- 2026: 1 · 2025: 7 · 2024: 7 · 2023: 5 · 2022: 10 · 2021: 9 · 2020: 8 · 2019: 10 · 2018: 13 · 2017: 10 · 2016: 10 · 2015: 18 · 2014: 17 · 2013: 8 · 2012: 15
- FWCI
- 1.03
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Brain Research Bulletin (publishedVersion)
- PubMed (publishedVersion)
- Funders
- University of Alberta
- Deutscher Akademischer Austauschdienst
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Keywords
- Utah electrode array, microelectrode arrays, sciatic nerve, peripheral nerve recording, peripheral nerve stimulation, nerve compression, compound action potential, single-unit recording, multi-unit recording, muscle twitch, neuroprosthetics
- MeSH terms
- Action Potentials, Animals, Cats, Electric Stimulation, Microelectrodes, Muscle Contraction, Sciatic Nerve, Muscle, Skeletal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review