The DOI matches its Crossref record; 52 of the 53 references it cites were found in a registry or an index.
A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Abstract
The feasibility of implanting an array of penetrating electrodes into peripheral nerves is studied in acute experiments in the cat sciatic nerve. A novel, silicon-based array of microelectrodes, the Utah Electrode Array, was used, which contains 25 or 100 1-mm long electrodes that project out from a silicon substrate. Electrode arrays of this complexity, when inserted in the peripheral nerve, could cause significant compression of the nerve and block the conduction of action potentials. Using a high velocity insertion technique, the electrode array was implanted into the sciatic nerve. Compound action potentials were evoked by and recorded with cuff electrodes. Compound action potentials recorded 1 h after insertion were only slightly altered from those recorded before insertion. Single units were readily extracted from evoked multiunit neural recordings in response to cutaneous stimulation and limb rotation around joints. Current injections into the nerve through the electrodes evoked muscle twitches with currents in the 10 microA range. Recording and stimulation stability were demonstrated for periods of up to 60 h. We have shown that high density arrays of electrodes can be inserted into the peripheral nerve and can provide a stable recording and stimulating interface to individual peripheral nerve axons. Such an array may be useful in future neuroscience research and potential neuroprosthetic applications.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Electrodes in the array were capable of selectively recording single-unit responses from mechanoreceptors, although only in 10-20% of the electrodes, and evoked graded recruitment of force in muscle groups in a highly selective fashion with current injections in the 1-20 m A range (Branner and Norman, 2000; Branner et al., 2001) .”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Branner and Norman, 2000
In the citing paper
“We have shown that the production of a defined geometric surface area (GSA) of the electrode tips was possible using either an oxygen plasma etching technique [1,21] or by excimer laser ablation [22].”
From A new high-density (25 electrodes/mm2) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures (2013) · cites this paper as [1]
In the citing paper
“Currently, there is one high electrode-density (6.25 electrodes/mm 2 ), high electrodecount (96 electrodes) penetrating device available for neuromodulation of large structures (> 4 mm) in the peripheral nervous system [1].”
From A new high-density (25 electrodes/mm2) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures (2013) · cites this paper as [1]
In the citing paper
“The electrode proportions, impedances, number of functionally distinct electrodes and SNR of HD-USEAs are comparable to the conventionally spaced Utah electrode arrays [1,13].”
From A new high-density (25 electrodes/mm2) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures (2013) · cites this paper as [1]
In the citing paper
“The conventionally spaced, lower density USEA can be implanted both acutely (<1 days) [1] and chronically (>6 months) [40,41] with insult to the epineurium or perinerium limited to the areas penetrated by the microelectrodes.”
From A new high-density (25 electrodes/mm2) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures (2013) · cites this paper as [1]
In the citing paper
“Moreover, there was little compression of the nerve fibers around the tips and shanks of the HD-USEA electrodes, as had been previously noted for the conventionally spaced USEAs [1].”
From A new high-density (25 electrodes/mm2) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures (2013) · cites this paper as [1]
Citations
Cites
Somatosensory, proprioceptive, and sympathetic activity in human peripheral nerves
Vallbo, A. B., Hagbarth, K. E., Torebjork, H. E., & Wallin, B. G. (1979) · Physiological Reviews · doi:10.1152/physrev.1979.59.4.919 · Cited by 1,507
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
Self-citationMaynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
Self-citationSingle unit recording capabilities of a 100 microelectrode array
Nordhausen, C. T., Maynard, E. M., & Normann, R. A. (1996) · Brain Research · doi:10.1016/0006-8993(96)00321-6 · Cited by 358
Self-citationA glass/silicon composite intracortical electrode array
Jones, K. E., Campbell, P. K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368134 · Cited by 354
Self-citationAFFERENT IMPULSES IN CUTANEOUS SENSORY NERVES IN HUMAN SUBJECTS
Hensel, H., & Boman, K. (1960) · Journal of Neurophysiology · doi:10.1152/jn.1960.23.5.564 · Cited by 323
Selective control of muscle activation with a multipolar nerve cuff electrode
Veraart, C., Grill, W. M., & Mortimer, J. T. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237694 · Cited by 320
A method for pneumatically inserting an array of penetrating electrodes into cortical tissue
Rousche, P. J., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368133 · Cited by 305
Self-citationCuff electrodes for chronic stimulation and recording of peripheral nerve activity
Loeb, G. E., & Peck, R. A. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00123-9 · Cited by 215
Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
Yoshida, K., & Horch, K. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.243412 · Cited by 208
Biocompatibility of silicon‐based electrode arrays implanted in feline cortical tissue
Schmidt, S., Horch, K., & Normann, R. A. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820271106 · Cited by 182
Self-citationClosed-loop class E transcutaneous power and data link for MicroImplants
Troyk, P. R., & Schwan, M. A. K. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141197 · Cited by 177
Chronically implanted intrafascicular recording electrodes
Lefurge, T., Goodall, E., Horch, K., Stensaas, L., & Schoenberg, A. (1991) · Annals of Biomedical Engineering · doi:10.1007/bf02368469 · Cited by 172
Hagbarth, K. E., & Vallbo, Å. B. (1967) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1967.tb03498.x · Cited by 169
Kovacs, G. T. A., Storment, C. W., Halks-Miller, M., Belczynski, C. R., Santina, C. C. D., Lewis, E. R., & Maluf, N. I. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.293244 · Cited by 161
THE RECORDING OF NERVE ACTION POTENTIALS THROUGH SKIN IN MAN
Dawson, G. D., & Scott, J. W. (1949) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.12.4.259 · Cited by 158
Rice, A. S. C., & McMahon, S. B. (1992) · British Journal of Anaesthesia · doi:10.1093/bja/69.5.433 · Cited by 154
A single-channel implantable microstimulator for functional neuromuscular stimulation
Ziaie, B., Nardin, M., Coghlan, A. R., & Najafi, K. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.634643 · Cited by 138
Micromodular implants to provide electrical stimulation of paralyzed muscles and limbs
Cameron, T., Loeb, G. E., Peck, R. A., Schulman, J. H., Strojnik, P., & Troyk, P. R. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623047 · Cited by 136
Yoshida, K., & Horch, K. W. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.481986 · Cited by 132
Sensitivity and selectivity of intraneural stimulation using a silicon electrode array
Rutten, W. L. C., van Wier, H. J., & Put, J. H. M. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.76386 · Cited by 130
Microneuronography and its relation to perceived sensation. a critical review
Wall, P. D., & McMahon, S. B. (1985) · Pain · doi:10.1016/0304-3959(85)90086-7 · Cited by 124
Neural signals for command control and feedback in functional neuromuscular stimulation: a review.
Hoffer, J. A., Rb, S., Haugland, M. K., Sinkjær, T., Durfee, W. K., Schwartz, A., Loeb, G. E., & Kantor, C. (1996) · PubMed · Cited by 120
A slowly penetrating interfascicular nerve electrode for selective activation of peripheral nerves
Tyler, D. J., & Durand, D. M. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559349 · Cited by 108
DAVIS, L. A., Gordon, T., Hoffer, J. A., Jhamandas, J. H., & Stein, R. B. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012588 · Cited by 103
Rijkhoff, N., Wijkstra, H., Kerrebroeck, P. V., & Debruyne, F. M. J. (1997) · Neurourology and Urodynamics · doi:10.1002/(sici)1520-6777(1997)16:1 · Cited by 99
Selective activation of muscles using peripheral nerve electrodes
McNeal, D. R., & Bowman, B. R. (1985) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446866 · Cited by 97
Muscle recruitment with intrafascicular electrodes
Nannini, N., & Horch, K. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83589 · Cited by 94
Bowman, B. R., & Erickson, R. C. (1985) · Annals of Biomedical Engineering · doi:10.1007/bf02371251 · Cited by 66
Techniques to Study Spinal-Cord, Peripheral Nerve, and Muscle Activity in Freely Moving Animals
Hoffer, J. A. (2003) · Humana Press eBooks · doi:10.1385/0-89603-185-3:65 · Cited by 66
Multielectrode intrafascicular and extraneural stimulation
Veltink, P. H., van Alsté, J. A., & Boom, H. B. K. (1989) · Medical and Biological Engineering and Computing · doi:10.1007/bf02442165 · Cited by 62
Direct membrane resting and action potentials from single myelinated nerve fibers
Woodbury, J. W. (1952) · Journal of Cellular and Comparative Physiology · doi:10.1002/jcp.1030390210 · Cited by 57
Vallbo, Å. B. (1976) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1976.tb10236.x · Cited by 55
Neuromuscular stimulation selectivity of multiple-contact nerve cuff electrode arrays
Sweeney, J. D., Crawford, N. R., & Brandon, T. A. (1995) · Medical & Biological Engineering & Computing · doi:10.1007/bf02510525 · Cited by 51
Clinical experience with a helical bipolar stimulating lead
TARVER, W. B., GEORGE, R. E., MASCHINO, S. E., HOLDER, L. K., & WERNICKE, J. F. (1992) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1992.tb02933.x · Cited by 46
Axotomy-induced changes in rabbit hindlimb nerves and the effects of chronic electrical stimulation
Gordon, T., Gillespie, J. G., Orozco, R., & DAVIS, L. A. (1991) · Journal of Neuroscience · doi:10.1523/jneurosci.11-07-02157.1991 · Cited by 44
Non-invasive measurement of the input-output properties of peripheral nerve stimulating electrodes
Grill, W. M., & Mortimer, J. T. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00143-3 · Cited by 41
Multielectrode spiral cuff for ordered and reversed activation of nerve fibres
Rozman, J., Sovinec, B., Trlep, M., & Zorko, B. (1993) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(93)90039-2 · Cited by 41
Recruitment data for nerve cuff electrodes: implications for design of implantable stimulators
McNeal, D. R., Baker, L. L., & Symons, J. T. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.19851 · Cited by 35
Slot, P. J., Selmar, P. E., Rasmussen, A., & Sinkjær, T. (1997) · PubMed · Cited by 26
Implantable stimulator for selective stimulation of the common peroneal nerve: a preliminary report
Rozman, J., Aćimović-Janežič, R., Tekavčič, I., Kljajić, M. V., & Trlep, M. (1994) · Journal of Medical Engineering & Technology · doi:10.3109/03091909409030228 · Cited by 25
Fried, K., Frisén, J., & Mozart, M. (1989) · Pain · doi:10.1016/0304-3959(89)90116-4 · Cited by 23
Rice, A. S. C., Andreev, N. Y., & McMahon, S. B. (1994) · Pain · doi:10.1016/0304-3959(94)90025-6 · Cited by 22
Hallin, R. G., Wiesenfeld‐Hallin, Z., & Duranti, R. (1986) · Neuroscience Letters · doi:10.1016/0304-3940(86)90516-1 · Cited by 19
The electrophysiological consequences of electrode impalement of peripheral nerves in the rat
Rice, A. S. C., McMahon, S. B., & Wall, P. D. (1993) · Brain Research · doi:10.1016/0006-8993(93)91538-4 · Cited by 18
KOLLER, R., GIRSCH, W., LIEGL, C., CRUDER, H., HOLLE, J., LOSERT, U., MAYR, W., & THOMA, H. (1992) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1992.tb02906.x · Cited by 17
Protocol for microneurography with concentric needle electrodes
Hallin, R. G., & Wu, G. (1998) · Brain Research Protocols · doi:10.1016/s1385-299x(97)00025-1 · Cited by 16
Selectivity of intraneural prosthetic interfaces for muscular control
Rutten, W. L. C., & Meier, J. H. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446095 · Cited by 15
Force recruitment during electrical nerve stimulation with multipolar intrafascicular electrodes
Meier, J. H., Rutten, W. L. C., & Boom, H. B. K. (1995) · Medical & Biological Engineering & Computing · doi:10.1007/bf02510524 · Cited by 15
Physiological characterization of motor unit properties in intact cats
O'Donovan, M. J., Hoffer, J. A., & Loeb, G. E. (1983) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(83)90076-6 · Cited by 12
A method for evaluating the selectivity of electrodes implanted for nerve simulation
Liang, D. H., Kovacs, G. T. A., Storment, C. W., & White, R. L. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.81563 · Cited by 12
Theophilidis, G., & Pavlidou, P. (1993) · PubMed · Cited by 10
Research works printed but not linked: 1
- Branner, 1996, A 20 channel peripheral nerve interface, Soc. Neurosci. Abstr., 22, 668
Cited by
Sorted by citations
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454
“Utah arrays were developed in the early 1990s as a means to deploy large numbers of electrodes to deep layers of the brain (Normann and Fernandez, 2016), and have since been adapted for use in nerves (Branner and Normann, 2000; Branner et al., 2001).”
Background
Metadata
- Authors
- Branner, A., & Normann, R. A.
- Affiliations
- University of Utah (US)
- Corresponding author
- Normann, Richard Alan
- Venue
- Brain Research Bulletin
- Publisher
- Elsevier BV
- Published
- 2000-03
- Volume
- 51
- Issue
- 4
- Pages
- 293-306
- ISSN
- 0361-9230 (ISSN-L)
- OpenAlex
- W1970923678
- Semantic Scholar
- 99213097ea1e1f7e51940a5e1ab0673dd53a0f0c
- Cited by
- 234
- References
- 53
- Citations by year
- 2026: 1 · 2025: 7 · 2024: 7 · 2023: 5 · 2022: 10 · 2021: 9 · 2020: 8 · 2019: 10 · 2018: 13 · 2017: 10 · 2016: 10 · 2015: 18 · 2014: 17 · 2013: 8 · 2012: 15
- FWCI
- 1.03
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Brain Research Bulletin (publishedVersion)
- PubMed (publishedVersion)
- Funders
- University of Alberta
- Deutscher Akademischer Austauschdienst
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Keywords
- Utah electrode array, microelectrode arrays, sciatic nerve, peripheral nerve recording, peripheral nerve stimulation, nerve compression, compound action potential, single-unit recording, multi-unit recording, muscle twitch, neuroprosthetics
- MeSH terms
- Action Potentials, Animals, Cats, Electric Stimulation, Microelectrodes, Muscle Contraction, Sciatic Nerve, Muscle, Skeletal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review