The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Wearable Bioelectronics: Enzyme-Based Body-Worn Electronic Devices
Open accessAbstract
In this Account, we detail recent progress in wearable bioelectronic devices and discuss the future challenges and prospects of on-body noninvasive bioelectronic systems. Bioelectronics is a fast-growing interdisciplinary research field that involves interfacing biomaterials with electronics, covering an array of biodevices, encompassing biofuel cells, biosensors, ingestibles, and implantables. In particular, enzyme-based bioelectronics, built on diverse biocatalytic reactions, offers distinct advantages and represents a centerpiece of wearable biodevices. Such wearable bioelectronic devices predominately rely on oxidoreductase enzymes and have already demonstrated considerable promise for on-body applications ranging from highly selective noninvasive biomarker monitoring to epidermal energy harvesting. These systems can thus greatly increase the analytical capability of wearable devices from the ubiquitous monitoring of mobility and vital signs, toward the noninvasive analysis of important chemical biomarkers. Wearable enzyme electrodes offer exciting opportunities to a variety of areas, spanning from healthcare, sport, to the environment or defense. These include real-time noninvasive detection of biomarkers in biofluids (such as sweat, saliva, interstitial fluid and tears), and the monitoring of environmental pollutants and security threats in the immediate surrounding of the wearer. Furthermore, the interface of enzymes with conducting flexible electrode materials can be exploited for developing biofuel cells, which rely on the bioelectrocatalytic oxidation of biological fuels, such as lactate or glucose, for energy harvesting applications. Crucial for such successful application of enzymatic bioelectronics is deep knowledge of enzyme electron-transfer kinetics, enzyme stability, and enzyme immobilization strategies. Such understanding is critical for establishing efficient electrical contacting between the redox enzymes and the conducting electrode supports, which is of fundamental interest for the development of robust and efficient bioelectronic platforms. Furthermore, stretchable and flexible bioelectronic platforms, with mechanical properties similar to those of biological tissues, are essential for handling the rigors of on-body operation. As such, special attention must be given to changes in the behavior of enzymes due to the uncontrolled conditions of on-body operation (including diverse outdoor activities and different biofluids), for maintaining the attractive performance that these bioelectronics devices display in controlled laboratory settings. Therefore, a focus of this Account is on interfacing biocatalytic layers onto wearable electronic devices for creating efficient and stable on-body electrochemical biosensors and biofuel cells. With proper attention to key challenges and by leveraging the advantages of biocatalysis, electrochemistry, and flexible electronics, wearable bioelectronic devices could have a tremendous impact on diverse biomedical, fitness, and defense fields.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Stretchable, Skin-Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review
Amjadi, M., Kyung, K., Park, I., & Sitti, M. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504755 · Cited by 3,202
Wearable Electronics and Smart Textiles: A Critical Review
Stoppa, M., & Chiolerio, A. (2014) · Sensors · doi:10.3390/s140711957 · Cited by 2,107
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Self-citationImmobilization strategies to develop enzymatic biosensors
Sassolas, A., Blum, L. J., & Leca-Bouvier, B. D. (2012) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.09.003 · Cited by 1,130
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Self-citationImani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861
Self-citationWang, J. (2006) · Wiley eBooks · doi:10.1002/0471790303 · Cited by 847
Self-citationSensor and biosensor preparation, optimisation and applications of Prussian Blue modified electrodes
Ricci, F., & Palleschi, G. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.001 · Cited by 781
Wearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778
Self-citationGlucose Biosensors: 40 Years of Advances and Challenges
Wang, J. (2001) · Electroanalysis · doi:10.1002/1521-4109(200108)13:12<983::aid-elan983>3.0.co;2-# · Cited by 752
Self-citationTattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700
Self-citationWearable salivary uric acid mouthguard biosensor with integrated wireless electronics
Kim, J., Imani, S., de Araujo, W. R., Warchall, J., Valdés-Ramírez, G., Paixão, T. R. L. C., Mercier, P. P., & Wang, J. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.039 · Cited by 678
Self-citationChitosan based hydrogels: characteristics and pharmaceutical applications.
Ahmadi, F., Ovaisi, Z., Samani, S. M., & Amoozgar, Z. (2015) · PubMed Central · Cited by 654
Immobilization of glucose oxidase in ferrocene-modified pyrrole polymers
Foulds, N. C., & Lowe, C. R. (1988) · Analytical Chemistry · doi:10.1021/ac00173a008 · Cited by 613
Noninvasive Alcohol Monitoring Using a Wearable Tattoo-Based Iontophoretic-Biosensing System
Kim, J., Jeerapan, I., Imani, S., Cho, T. N., Bandodkar, A., Cinti, S., Mercier, P. P., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00356 · Cited by 599
Self-citationWearable non-invasive epidermal glucose sensors: A review
Kim, J., Campbell, A. S., & Wang, J. (2018) · Talanta · doi:10.1016/j.talanta.2017.08.077 · Cited by 586
Self-citationSimultaneous Monitoring of Sweat and Interstitial Fluid Using a Single Wearable Biosensor Platform
Kim, J., Sempionatto, J. R., Imani, S., Hartel, M. C., Barfidokht, A., Tang, G., Campbell, A. S., Mercier, P. P., & Wang, J. (2018) · Advanced Science · doi:10.1002/advs.201800880 · Cited by 526
Self-citationMartín, A., Kim, J., Kurniawan, J. F., Sempionatto, J. R., Moreto, J. R., Tang, G., Campbell, A. S., Shin, A., Lee, M. Y., Liu, X., et al. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00729 · Cited by 475
Self-citationA review of the immobilization of enzymes in electropolymerized films
Barlett, P. N., & Cooper, J. M. (1993) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(93)80001-x · Cited by 472
Prussian Blue-Based First-Generation Biosensor. A Sensitive Amperometric Electrode for Glucose
Karyakin, A. A., Gitelmacher, O. V., & Karyakina, E. E. (1995) · Analytical Chemistry · doi:10.1021/ac00110a016 · Cited by 456
Anti-fouling Coatings of Poly(dimethylsiloxane) Devices for Biological and Biomedical Applications
Zhang, H., & Chiao, M. (2015) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-015-0029-4 · Cited by 415
Bandodkar, A. J., You, J.-M., Kim, N.-H., Gu, Y., Kumar, R., Mohan, A. M. V., Kurniawan, J., Imani, S., Nakagawa, T., Parish, B., et al. (2017) · Energy & Environmental Science · doi:10.1039/c7ee00865a · Cited by 412
Self-citationEnzyme catalysed biofuel cells
Cooney, M. J., Svoboda, V., Lau, C., Martin, G., & Minteer, S. D. (2008) · Energy & Environmental Science · doi:10.1039/b809009b · Cited by 391
Integrated Enzyme‐Based Biofuel Cells–A Review
Willner, I., Yan, Y. ‐., Willner, B., & Tel‐Vered, R. (2009) · Fuel Cells · doi:10.1002/fuce.200800115 · Cited by 378
Non-invasive mouthguard biosensor for continuous salivary monitoring of metabolites
Kim, J., Valdés-Ramírez, G., Bandodkar, A. J., Jia, W., Martinez, A. G., Ramírez, J., Mercier, P., & Wang, J. (2014) · The Analyst · doi:10.1039/c3an02359a · Cited by 367
Self-citationCharacterization of implantable biosensor membrane biofouling
Wisniewski, N., Moussy, F., & Reichert, W. M. (2000) · Fresenius' Journal of Analytical Chemistry · doi:10.1007/s002160051556 · Cited by 350
Mishra, R. K., Hubble, L. J., Martín, A., Kumar, R., Barfidokht, A., Kim, J., Musameh, M. M., Kyratzis, I. L., & Wang, J. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00051 · Cited by 345
Self-citationA potentiometric tattoo sensor for monitoring ammonium in sweat
Guinovart, T., Bandodkar, A. J., Windmiller, J. R., Andrade, F. J., & Wang, J. (2013) · The Analyst · doi:10.1039/c3an01672b · Cited by 343
Self-citationBandodkar, A. J., Jeerapan, I., You, J.-M., Nuñez-Flores, R., & Wang, J. (2016) · Nano Letters · doi:10.1021/acs.nanolett.5b04549 · Cited by 341
Self-citationMicroneedle array for transdermal biological fluid extraction and in situ analysis
Mukerjee, E. V., Collins, S. D., Isseroff, R. R., & Smith, R. L. (2004) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2003.11.008 · Cited by 340
Epidermal Biofuel Cells: Energy Harvesting from Human Perspiration
Jia, W., Valdés‐Ramírez, G., Bandodkar, A. J., Windmiller, J. R., & Wang, J. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201302922 · Cited by 324
Self-citationStretchable biofuel cells as wearable textile-based self-powered sensors
Jeerapan, I., Sempionatto, J. R., Pavinatto, A., You, J.-M., & Wang, J. (2016) · Journal of Materials Chemistry A · doi:10.1039/c6ta08358g · Cited by 317
Self-citationEyeglasses based wireless electrolyte and metabolite sensor platform
Sempionatto, J. R., Nakagawa, T., Pavinatto, A., Mensah, S. T., Imani, S., Mercier, P., & Wang, J. (2017) · Lab on a Chip · doi:10.1039/c7lc00192d · Cited by 311
Self-citationLaboratorium Farmakognosi, F. F. U. M. I., Ahmad, A. R., Juwita, J., Laboratorium Farmakognosi, F. F. U. M. I., Ratulangi, S. A. D., & Laboratorium Farmakognosi, F. F. U. M. I. (2015) · Pharmaceutical Sciences and Research · doi:10.7454/psr.v2i1.3481 · Cited by 303
Continuous minimally-invasive alcohol monitoring using microneedle sensor arrays
Mohan, A. M. V., Windmiller, J. R., Mishra, R. K., & Wang, J. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.01.016 · Cited by 274
Self-citationWearable Wireless Tyrosinase Bandage and Microneedle Sensors: Toward Melanoma Screening
Ciui, B., Martin, A., Mishra, R. K., Brunetti, B., Nakagawa, T., Dawkins, T. J., Lyu, M., Cristea, C., Sandulescu, R., & Wang, J. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701264 · Cited by 262
Self-citationEngineering hybrid nanotube wires for high-power biofuel cells
Gao, F., Viry, L., Maugey, M., Poulin, P., & Mano, N. (2010) · Nature Communications · doi:10.1038/ncomms1000 · Cited by 246
Implanted biofuel cells operating in vivo – methods, applications and perspectives – feature article
Katz, E., & MacVittie, K. (2013) · Energy & Environmental Science · doi:10.1039/c3ee42126k · Cited by 228
All‐Printed Stretchable Electrochemical Devices
Bandodkar, A. J., Nuñez‐Flores, R., Jia, W., & Wang, J. (2015) · Advanced Materials · doi:10.1002/adma.201500768 · Cited by 199
Self-citationWearable Biofuel Cells: A Review
Bandodkar, A. J., & Wang, J. (2016) · Electroanalysis · doi:10.1002/elan.201600019 · Cited by 193
Self-citationMicroneedle-based self-powered glucose sensor
Valdés-Ramírez, G., Li, Y.-C., Kim, J., Jia, W., Bandodkar, A. J., Nuñez-Flores, R., Miller, P. R., Wu, S.-Y., Narayan, R., Windmiller, J. R., et al. (2014) · Electrochemistry Communications · doi:10.1016/j.elecom.2014.07.014 · Cited by 188
Self-citationNormal Human Tear pH by Direct Measurement
Abelson, M. B., Udell, I. J., & Weston, J. H. (1981) · Archives of Ophthalmology · doi:10.1001/archopht.1981.03930010303017 · Cited by 182
Newman, J. D., & Setford, S. J. (2006) · Molecular Biotechnology · doi:10.1385/mb:32:3:249 · Cited by 180
Electrochemical sensing based on printable temporary transfer tattoos
Windmiller, J. R., Bandodkar, A. J., Valdés-Ramírez, G., Parkhomovsky, S., Martinez, A. G., & Wang, J. (2012) · Chemical Communications · doi:10.1039/c2cc32839a · Cited by 169
Self-citationAn epidermal alkaline rechargeable Ag–Zn printable tattoo battery for wearable electronics
Berchmans, S., Bandodkar, A. J., Jia, W., Ramírez, J., Meng, Y. S., & Wang, J. (2014) · J. Mater. Chem. A · doi:10.1039/c4ta03256j · Cited by 149
Self-citationZhou, M., Zhou, N., Kuralay, F., Windmiller, J. R., Parkhomovsky, S., Valdés‐Ramírez, G., Katz, E., & Wang, J. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201107068 · Cited by 147
Self-citationA comparative review of cutaneous pH
Matousek, J. L., & CAMPBELL, K. L. (2002) · Veterinary Dermatology · doi:10.1046/j.1365-3164.2002.00312.x · Cited by 139
Wearable potentiometric tattoo biosensor for on-body detection of G-type nerve agents simulants
Mishra, R. K., Barfidokht, A., Karajić, A., Sempionatto, J. R., Wang, J., & Wang, J. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.07.001 · Cited by 129
Self-citationElectrochemical glucose biosensors
Wang, J. (2008) · Elsevier eBooks · doi:10.1016/b978-012373738-0.50005-2 · Cited by 122
Self-citationWearable Ring-Based Sensing Platform for Detecting Chemical Threats
Sempionatto, J. R., Mishra, R. K., Martín, A., Tang, G., Nakagawa, T., Lu, X., Campbell, A. S., Lyu, K. M., & Wang, J. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00603 · Cited by 117
Self-citationA microneedle biosensor for minimally-invasive transdermal detection of nerve agents
Mishra, R. K., Mohan, A. M. V., Soto, F., Chrostowski, R. R., & Wang, J. (2017) · The Analyst · doi:10.1039/c6an02625g · Cited by 110
Self-citationMishra, R. K., Martín, A., Nakagawa, T., Barfidokht, A., Lu, X., Sempionatto, J. R., Lyu, K. M., Karajić, A., Musameh, M. M., Kyratzis, I. L., et al. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.10.044 · Cited by 110
Self-citation(2014) · Wiley eBooks · doi:10.1002/9783527673148 · Cited by 104
Thermal Stabilization of Enzymes Immobilized within Carbon Paste Electrodes
Wang, J., Liu, J., & Cepra, G. (1997) · Analytical Chemistry · doi:10.1021/ac9702305 · Cited by 95
Self-citationMohan, A. M. V., Kim, N.-H., Gu, Y. Q., Bandodkar, A. J., You, J., Kumar, R., Kurniawan, J. F., Xu, S. H., & Wang, J. (2017) · Advanced Materials Technologies · doi:10.1002/admt.201600284 · Cited by 87
Self-citationJeerapan, I., Ciui, B., Martin, I., Cristea, C., Săndulescu, R., & Wang, J. (2018) · Journal of Materials Chemistry B · doi:10.1039/c8tb00497h · Cited by 37
Self-citationNguyen, K. V., Giroud, F., & Minteer, S. D. (2014) · Journal of The Electrochemical Society · doi:10.1149/2.0761414jes · Cited by 32
Cited by
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Lim, H., Kim, H. S., Qazi, R., Kwon, Y., Jeong, J., & Yeo, W. (2020) · Advanced Materials · doi:10.1002/adma.201901924 · Cited by 1,002
Electrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Teymourian, H., Barfidokht, A., & Wang, J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00304b · Cited by 881
Self-citationFlexible Hybrid Sensors for Health Monitoring: Materials and Mechanisms to Render Wearability
Gao, Y., Yu, L., Yeo, J. C., & Lim, C. T. (2020) · Advanced Materials · doi:10.1002/adma.201902133 · Cited by 505
Tackling the Challenges of Enzymatic (Bio)Fuel Cells
Xiao, X., Xia, H.-Q., Wu, R., Bai, L., Yan, L., Magner, E., Cosnier, S., Lojou, E., Zhu, Z., & Liu, A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00115 · Cited by 504
Metadata
- Authors
- Kim, J., Jeerapan, I., Sempionatto, J. R., Barfidokht, A., Mishra, R. K., Campbell, A. S., Hubble, L. J., & Wang, J.
- Venue
- Accounts of Chemical Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-11-06
- Volume
- 51
- Issue
- 11
- Pages
- 2820-2828
- ISSN
- 0001-4842 (ISSN-L)
- 1520-4898
- OpenAlex
- W2899980179
- Cited by
- 289
- References
- 59
- FWCI
- 11.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.