The Effects of Outdoor Air Supply Rate in an Office on Perceived Air Quality, Sick Building Syndrome (SBS) Symptoms and Productivity
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Perceived air quality, Sick Building Syndrome (SBS) symptoms and productivity were studied in a normally furnished office space (108 m3) ventilated with an outdoor airflow of 3, 10 or 30 L/s per person, corresponding to an air change rate of 0.6, 2 or 6 h-1. The temperature of 22 degrees C, the relative humidity of 40% and all other environmental parameters remained unchanged. Five groups of six female subjects were each exposed to the three ventilation rates, one group and one ventilation rate at a time. Each exposure lasted 4.6 h and took place in the afternoon. Subjects were unaware of the intervention and remained thermally neutral by adjusting their clothing. They assessed perceived air quality and SBS symptoms at intervals, and performed simulated normal office work. Increasing ventilation decreased the percentage of subjects dissatisfied with the air quality (P < 0.002) and the intensity of odour (P < 0.02), and increased the perceived freshness of air (P < 0.05). It also decreased the sensation of dryness of mouth and throat (P < 0.0006), eased difficulty in thinking clearly (P < 0.001) and made subjects feel generally better (P < 0.0001). The performance of four simulated office tasks improved monotonically with increasing ventilation rates, and the effect reached formal significance in the case of text-typing (P < 0.03). For each two-fold increase in ventilation rate, performance improved on average by 1.7%. This study shows the benefits for health, comfort and productivity of ventilation at rates well above the minimum levels prescribed in existing standards and guidelines. It confirms the results of a previous study in the same office when the indoor air quality was improved by decreasing the pollution load while the ventilation remained unchanged.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Statistics for the Behavioral Sciences
Guitton, H., & Siegel, S. (1958) · Revue économique · doi:10.2307/3498751 · Cited by 35,245
Nonparametric Statistics for the Behavioral Sciences.
Whitfield, J. W., & Siegel, S. (1957) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2342828 · Cited by 7,947
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876
Redlich, C. A., Sparer, J., & Cullen, M. R. (1997) · The Lancet · doi:10.1016/s0140-6736(96)07220-0 · Cited by 759
Design and Analysis of Experiments, 3rd Ed.
Nelson, P. R. (1991) · Journal of Quality Technology · doi:10.1080/00224065.1991.11979363 · Cited by 569
Wargocki, P., Wyon, D. P., Baik, Y. K., Clausen, G., & Fanger, P. O. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.t01-1-00003.x · Cited by 507
Self-citationFanger, P. O. (1988) · Energy and Buildings · doi:10.1016/0378-7788(88)90051-5 · Cited by 371
Self-citationField experiments on occupant comfort and office thermal environments in a hot-humid climate
de Dear, R., & Fountain, M. (1994) · Macquarie University · Cited by 285
Non-Specific Symptoms In Office Workers: A Review And Summary Of The Epidemiologic Literature
Mendell, M. J. (1993) · Indoor Air · doi:10.1111/j.1600-0668.1993.00003.x · Cited by 284
European Indoor Air Quality Audit Project in 56 Office Buildings
Bluyssen, P. M., Oliveira Fernandes, E., Groes, L., Clausen, G., Fanger, P. O., Valbjorn, O., Bernhard, C. A., & Roulet, C. A. (1996) · Indoor Air · doi:10.1111/j.1600-0668.1996.00002.x · Cited by 237
Self-citation
Cited by
Satish, U., Mendell, M. J., Shekhar, K., Hotchi, T., Sullivan, D., Streufert, S., & Fisk, W. J. (2012) · Environmental Health Perspectives · doi:10.1289/ehp.1104789 · Cited by 1,064
Mendell, M. J., & Heath, G. A. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00320.x · Cited by 1,034
Allen, J. G., MacNaughton, P., Satish, U., Santanam, S., Vallarino, J., & Spengler, J. D. (2016) · Environmental Health Perspectives · doi:10.1289/ehp.1510037 · Cited by 977
“…building factors, such as ventilation rate; workspace factors, such as the presence of chemical-emitting materials; and personal factors, such as job stress, allergies, and sex (Mendell 1993; Wargocki et al. 2000; Bornehag et al. 2005; Hedge 2009; Hedge and Gaygen 2010; Nishihara et al. 2014).”
Occupant productivity and office indoor environment quality: A review of the literature
Al Horr, Y., Arif, M., Kaushik, A., Mazroei, A., Katafygiotou, M., & Elsarrag, E. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.06.001 · Cited by 843
Al horr, Y., Arif, M., Katafygiotou, M., Mazroei, A., Kaushik, A., & Elsarrag, E. (2016) · International Journal of Sustainable Built Environment · doi:10.1016/j.ijsbe.2016.03.006 · Cited by 817
Ventilation rates and health: Multidisciplinary review of the scientific literature
Sundell, J., Levin, H., Nazaroff, W. W., Cain, W. S., Fisk, W. J., Grimsrud, D. T., Gyntelberg, F., Li, Y., Persily, A. K., Pickering, A. C., et al. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00703.x · Cited by 740
Self-citationOn the history of indoor air quality and health
Sundell, J. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00273.x · Cited by 613
Self-citationKim, J., Schiavon, S., & Brager, G. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.01.023 · Cited by 522
Wyon, D. P. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00278.x · Cited by 500
Self-citationKim, J., Zhou, Y., Schiavon, S., Raftery, P., & Brager, G. (2018) · Building and Environment · doi:10.1016/j.buildenv.2017.12.011 · Cited by 478
van Odijk, J., Kull, I., Borres, M. P., Brandtzaeg, P., Edberg, U., Hanson, L. Å., Høst, A., Kuitunen, M., Olsen, S. F., Skerfving, S., et al. (2003) · Allergy · doi:10.1034/j.1398-9995.2003.00264.x · Cited by 472
Self-citationWargocki, P., Sundell, J., Bischof, W., Brundrett, G., Fanger, P. O., Gyntelberg, F., Hanssen, S. O., Harrison, P., Pickering, A., Seppänen, O., et al. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01145.x · Cited by 418
Self-citationMeadow, J. F., Altrichter, A. E., Kembel, S. W., Kline, J., Mhuireach, G., Moriyama, M., Northcutt, D., O'Connor, T. K., Womack, A. M., Brown, G. Z., et al. (2014) · Indoor Air · doi:10.1111/ina.12047 · Cited by 411
Influence of indoor environmental quality on human health and productivity - A review
Mujan, I., Anđelković, A. S., Munćan, V., Kljajić, M., & Ružić, D. (2019) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2019.01.307 · Cited by 405
Outdoor-indoor air pollution in urban environment: challenges and opportunity
Leung, D. Y. C. (2015) · Frontiers in Environmental Science · doi:10.3389/fenvs.2014.00069 · Cited by 401
Tham, K. W. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.08.071 · Cited by 399
The impact of thermal environment on occupant IEQ perception and productivity
Geng, Y., Ji, W., Lin, B., & Zhu, Y. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.05.022 · Cited by 388
Fang, L., Wyon, D. P., Clausen, G., & Fanger, P. O. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00276.x · Cited by 380
Self-citationSenses of place: architectural design for the multisensory mind
Spence, C. (2020) · Cognitive Research: Principles and Implications · doi:10.1186/s41235-020-00243-4 · Cited by 380
Zhang, X., Wargocki, P., Lian, Z., & Thyregod, C. (2017) · Indoor Air · doi:10.1111/ina.12284 · Cited by 360
Self-citationLan, L., Wargocki, P., Wyon, D. P., & Lian, Z. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2011.00714.x · Cited by 355
Self-citationIndoor Mold, Toxigenic Fungi, and Stachybotrys chartarum: Infectious Disease Perspective
Kuhn, D. M., & Ghannoum, M. A. (2003) · Clinical Microbiology Reviews · doi:10.1128/cmr.16.1.144-172.2003 · Cited by 352
Sick building syndrome: Figure 1
Burge, P. S. (2004) · Occupational and Environmental Medicine · doi:10.1136/oem.2003.008813 · Cited by 345
The impact of a view from a window on thermal comfort, emotion, and cognitive performance
Ko, W. H., Schiavon, S., Zhang, H., Graham, L. T., Brager, G., Mauss, I., & Lin, Y.-W. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.106779 · Cited by 342
Providing better thermal and air quality conditions in school classrooms would be cost-effective
Wargocki, P., & Wyon, D. P. (2013) · Building and Environment · doi:10.1016/j.buildenv.2012.10.007 · Cited by 309
Self-citationHeinzerling, D., Schiavon, S., Webster, T., & Arens, E. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.08.027 · Cited by 308
Ventilation and performance in office work
Seppanen, O., Fisk, W. J., & Lei, Q. H. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00394.x · Cited by 303
Wargocki, P., & Wyon, D. P. (2017) · Building and Environment · doi:10.1016/j.buildenv.2016.11.020 · Cited by 290
Self-citationGender differences in office occupant perception of indoor environmental quality (IEQ)
Kim, J., de Dear, R., Cândido, C., Zhang, H., & Arens, E. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.08.022 · Cited by 267
The relationships between classroom air quality and children’s performance in school
Wargocki, P., Porras-Salazar, J. A., Contreras-Espinoza, S., & Bahnfleth, W. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.106749 · Cited by 263
Self-citationRashid, M., & Zimring, C. (2008) · Environment and Behavior · doi:10.1177/0013916507311550 · Cited by 252
Summary of human responses to ventilation
Seppanen, O. A., & Fisk, W. J. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00279.x · Cited by 249
Kelly, F. J., & Fussell, J. C. (2019) · Atmospheric Environment · doi:10.1016/j.atmosenv.2018.11.058 · Cited by 246
Sick building syndrome: are we doing enough?
Ghaffarianhoseini, A., AlWaer, H., Omrany, H., Ghaffarianhoseini, A., Alalouch, C., Clements-Croome, D., & Tookey, J. (2018) · Architectural Science Review · doi:10.1080/00038628.2018.1461060 · Cited by 238
Wei, X., Lyu, S., Yu, Y., Wang, Z., Liu, H., Pan, D., & Chen, J. (2017) · Frontiers in Plant Science · doi:10.3389/fpls.2017.01318 · Cited by 237
“Formaldehyde and BTX as main indoor VOCs contribute to the so-called “sick building syndrome” (Brown et al., 1994; Wieslander et al., 1996; Wargocki et al., 2000; Berg et al., 2014).”
BackgroundMendell, M. J., Fisk, W. J., Kreiss, K., Levin, H., Alexander, D., Cain, W. S., Girman, J. R., Hines, C. J., Jensen, P. A., Milton, D. K., et al. (2002) · American Journal of Public Health · doi:10.2105/ajph.92.9.1430 · Cited by 229
Witterseh, T., Wyon, D. P., & Clausen, G. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00305.x · Cited by 227
Self-citationKang, S., Ou, D., & Mak, C. M. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.07.003 · Cited by 225
The impact of working in a green certified building on cognitive function and health
MacNaughton, P., Satish, U., Laurent, J. G. C., Flanigan, S., Vallarino, J., Coull, B., Spengler, J. D., & Allen, J. G. (2017) · Building and Environment · doi:10.1016/j.buildenv.2016.11.041 · Cited by 219
Human exposure to ozone in school and office indoor environments
Salonen, H., Salthammer, T., & Morawska, L. (2018) · Environment International · doi:10.1016/j.envint.2018.07.012 · Cited by 218
“The lowest mean ozone concentration was measured in Denmark, which was within the designed ventilation rate of 3 L/(s · person) (Wargocki et al., 2000), and the highest mean ozone concentration rate was found in an Indian photocopy center during photocopying (Singh et al.”
BackgroundInfluentialEffects of moderate thermal environments on cognitive performance: A multidisciplinary review
Zhang, F., de Dear, R., & Hancock, P. (2019) · Applied Energy · doi:10.1016/j.apenergy.2018.12.005 · Cited by 217
Review on occupant-centric thermal comfort sensing, predicting, and controlling
Xie, J., Li, H., Li, C., Zhang, J., & Luo, M. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.110392 · Cited by 213
Human response to personalized ventilation and mixing ventilation
Kaczmarczyk, J., Melikov, A., & Fanger, P. O. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00300.x · Cited by 212
Self-citationI NDOOR A IR Q UALITY F ACTORS IN D ESIGNING A H EALTHY B UILDING
Spengler, J. D., & Chen, Q. (2000) · Annual Review of Energy and the Environment · doi:10.1146/annurev.energy.25.1.567 · Cited by 194
Wargocki, P., & Wyon, D. P. (2007) · HVAC&R Research · doi:10.1080/10789669.2007.10390950 · Cited by 194
“Additional reproduction, distribution, or transmission in either print or digital form is notpermitted without ASHRAE's prior written permission. office work performance is consequently affected by the rate at which clean outdoor air is supplied when such sources are present (Wargocki et al. 2000).”
BackgroundSelf-citationEnergy savings, emission reductions, and health co-benefits of the green building movement
P., M., X., C., J., B., J., C.-L., J., S., A., B., & J., A. (2018) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-017-0014-9 · Cited by 190
Indoor CO 2 concentrations and cognitive function: A critical review
Du, B., Tandoc, M. C., Mack, M. L., & Siegel, J. A. (2020) · Indoor Air · doi:10.1111/ina.12706 · Cited by 190
Indoor Air Quality Assessment Using a CO2 Monitoring System Based on Internet of Things
Marques, G., Ferreira, C. R., & Pitarma, R. (2019) · Journal of Medical Systems · doi:10.1007/s10916-019-1184-x · Cited by 182
Bako-Biro, Z., Wargocki, P., Weschler, C. J., & Fanger, P. O. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00218.x · Cited by 180
Self-citationBotanical biofiltration of indoor gaseous pollutants – A mini-review
Soreanu, G., Dixon, M., & Darlington, A. (2013) · Chemical Engineering Journal · doi:10.1016/j.cej.2013.06.074 · Cited by 179
Sol gel graphene/TiO2 nanoparticles for the photocatalytic-assisted sensing and abatement of NO2
Giampiccolo, A., Tobaldi, D. M., Leonardi, S. G., Murdoch, B. J., Seabra, M. P., Ansell, M. P., Neri, G., & Ball, R. J. (2019) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2018.10.032 · Cited by 175
Towards new methods and ways to create healthy and comfortable buildings
Bluyssen, P. M. (2010) · Building and Environment · doi:10.1016/j.buildenv.2009.08.020 · Cited by 173
Law, J., Van Baalen, M., Foy, M., Mason, S. S., Mendez, C., Wear, M. L., Meyers, V. E., & Alexander, D. (2014) · Journal of Occupational & Environmental Medicine · doi:10.1097/jom.0000000000000158 · Cited by 168
Bluyssen, P. M., Roda, C., Mandin, C., Fossati, S., Carrer, P., de Kluizenaar, Y., Mihucz, V. G., de Oliveira Fernandes, E., & Bartzis, J. (2016) · Indoor Air · doi:10.1111/ina.12196 · Cited by 167
Indoor air quality and energy management through real-time sensing in commercial buildings
Kumar, P., Martani, C., Morawska, L., Norford, L., Choudhary, R., Bell, M., & Leach, M. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2015.11.037 · Cited by 165
“Ventilation is an essential aspect of building operation, and it has been shown that an increase in ventilation rate can improve occupant health and productivity [25-30] and reduce the energy consumption of the Heating, Ventilation and Air Conditioning (HVAC) system of office buildings.”
BackgroundVehviläinen, T., Lindholm, H., Rintamäki, H., Pääkkönen, R., Hirvonen, A., Niemi, O., & Vinha, J. (2016) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2015.1076160 · Cited by 163
“(40-44) Our results show differences in the subjectively assessed, environmentally monitored, and physiologically measured parameters among employees working in office rooms.”
ResultProducts of Ozone-Initiated Chemistry in a Simulated Aircraft Environment
Wisthaler, A., Tamás, G., Wyon, D. P., Strøm-Tejsen, P., Space, D., Beauchamp, J., Hansel, A., Märk, T. D., & Weschler, C. J. (2005) · Environmental Science & Technology · doi:10.1021/es047992j · Cited by 162
Self-citationLocal cooling in a warm environment
Pallubinsky, H., Schellen, L., Rieswijk, T. A., Breukel, C. M. G. A. M., Kingma, B. R. M., & van Marken Lichtenbelt, W. D. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2015.12.016 · Cited by 54
Some Quantitative Relations between Indoor Environmental Quality and Work Performance or Health
Seppänen, O. A., & Fisk, W. (2006) · HVAC&R Research · doi:10.1080/10789669.2006.10391446 · Cited by 53
Measuring the productivity impacts of energy-efficiency: The case of high-efficiency buildings
Chatterjee, S., & Ürge-Vorsatz, D. (2021) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2021.128535 · Cited by 36
Metadata
- Authors
- WARGOCKI, P., WYON, D. P., SUNDELL, J., CLAUSEN, G., & FANGER, P. O.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2000-12
- Volume
- 10
- Issue
- 4
- Pages
- 222-236
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2099290073
- Cited by
- 688
- References
- 31
- FWCI
- 12.95
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.