Neuronal ensemble control of prosthetic devices by a human with tetraplegia
The DOI matches its Crossref record; 46 of the 47 references it cites were found in a registry or an index.
Abstract
Neuromotor prostheses (NMPs) aim to replace or restore lost motor functions in paralysed humans by routeing movement-related signals from the brain, around damaged parts of the nervous system, to external effectors. To translate preclinical results from intact animals to a clinically useful NMP, movement signals must persist in cortex after spinal cord injury and be engaged by movement intent when sensory inputs and limb movement are long absent. Furthermore, NMPs would require that intention-driven neuronal activity be converted into a control signal that enables useful tasks. Here we show initial results for a tetraplegic human (MN) using a pilot NMP. Neuronal ensemble activity recorded through a 96-microelectrode array implanted in primary motor cortex demonstrated that intended hand motion modulates cortical spiking patterns three years after spinal cord injury. Decoders were created, providing a 'neural cursor' with which MN opened simulated e-mail and operated devices such as a television, even while conversing. Furthermore, MN used neural control to open and close a prosthetic hand, and perform rudimentary actions with a multi-jointed robotic arm. These early results suggest that NMPs based upon intracortical neuronal ensemble spiking activity could provide a valuable new neurotechnology to restore independence for humans with paralysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Subcutaneous invasive electrophysiological signals can be derived through brain interfaces,[270–272] using electrocorticography (ECoG)[273,274] on the cortical surface as well as local field potentials (LFP)[275,276] extracted from electrodes inserted into the cortex.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [276]
In the citing paper
“Currently, all reported BMI experiments with human patients [26, 35, 57, 58, 150] require the subjects tethered percutaneously to a bench-top computer for neural signal acquisition and decoding.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [57]
In the citing paper
“Additionally, it is apparent from previous work that access to sufficiently large patient populations for concrete and statistically significant conclusions may be difficult to obtain (1–5, 8, 11, 29, 39).”
From Noninvasive neuroimaging enhances continuous neural tracking for robotic device control (2019) · cites this paper as [29]
Citations
Cites
Plum, F. (1960) · Archives of Neurology · doi:10.1001/archneur.1960.03840090124020 · Cited by 10,364
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Georgopoulos, A., Kalaska, J., Caminiti, R., & Massey, J. (1982) · The Journal of Neuroscience · doi:10.1523/jneurosci.02-11-01527.1982 · Cited by 2,130
International Standards for Neurological and Functional Classification of Spinal Cord Injury
Maynard, F. M., Bracken, M. B., Creasey, G., Jr, J. F. D., Donovan, W. H., Ducker, T. B., Garber, S. L., Marino, R. J., Stover, S. L., Tator, C. H., et al. (1997) · Spinal Cord · doi:10.1038/sj.sc.3100432 · Cited by 2,048
Advances in Neural Information Processing Systems 18
Murray, I., Mackay, D., Zoubin Ghahramani, A., & Skilling, J. (2006) · Cited by 1,927
Localization of the motor hand area to a knob on the precentral gyrus. A new landmark
Yousry, T. (1997) · Brain · doi:10.1093/brain/120.1.141 · Cited by 1,837
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Ditunno, J. F., Young, W., Donovan, W. H., & Creasey, G. (1994) · Spinal Cord · doi:10.1038/sc.1994.13 · Cited by 1,643
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Cited by
Items 701–800 of 1,022
Decoding onset and direction of movements using Electrocorticographic (ECoG) signals in humans
Wang, Z., Gunduz, A., Brunner, P., Ritaccio, A. L., Ji, Q., & Schalk, G. (2012) · Frontiers in Neuroengineering · doi:10.3389/fneng.2012.00015 · Cited by 72
“…or parietal cortices are related to the onset of movements (Achtman et al., 2007; Lebedev et al., 2008; Hwang and Andersen, 2009; Hasan and Gan, 2011; Mirabella et al., 2011), but access to intracortical activity in humans has been scarce (e.g., Hochberg et al., 2006; Simeral et al., 2011).”
BackgroundCortical stimulation mapping using epidurally implanted thin-film microelectrode arrays
Molina-Luna, K., Buitrago, M. M., Hertler, B., Schubring-Giese, M., Haiss, F., Nisch, W., Schulz, J. B., & Luft, A. R. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.10.025 · Cited by 74
Vogel, J., Haddadin, S., Jarosiewicz, B., Simeral, J. D., Bacher, D., Hochberg, L. R., Donoghue, J. P., & van der Smagt, P. (2015) · The International Journal of Robotics Research · doi:10.1177/0278364914561535 · Cited by 73
“If we take impractical recording techniques and those with poor temporal resolution out of consideration, we are left with the following methods: Electroencephalography (EEG); Electrocorticography (ECoG); Microelectrode arrays (MEAs).”
BackgroundMethodInfluentialSelf-citationNeural Interfaces at The Nanoscale
Pancrazio, J. J. (2008) · Nanomedicine · doi:10.2217/17435889.3.6.823 · Cited by 63
Chronic tissue response to untethered microelectrode implants in the rat brain and spinal cord
Ersen, A., Elkabes, S., Freedman, D. S., & Sahin, M. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016019 · Cited by 66
“quality of life for individuals with neurological disorders [1].”
BackgroundHsiao, Y., Liao, Y.-H., Chen, H.-L., Chen, P., & Chen, F. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b00916 · Cited by 65
SiC protective coating for photovoltaic retinal prosthesis
Lei, X., Kane, S., Cogan, S., Lorach, H., Galambos, L., Huie, P., Mathieson, K., Kamins, T., Harris, J., & Palanker, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046016 · Cited by 66
Hermes, D., Vansteensel, M. J., Albers, A. M., Bleichner, M. G., Benedictus, M. R., Méndez‐Orellana, C., Aarnoutse, E. J., & Ramsey, N. F. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025007 · Cited by 70
Recent advances in brain-computer interfaces
Ebrahimi, T. (2007) · IEEE International Workshop on Multimedia Signal Processing (MMSP) · doi:10.1109/mmsp.2007.4412807 · Cited by 65
“Neuronal ensemble activity can thus be employed as neurophysiological signal in BCIs, in particular in BCIs using microelectrode arrays [12].”
MethodA Review: Research Progress of Neural Probes for Brain Research and Brain–Computer Interface
Luo, J., Xue, N., & Chen, J. (2022) · Biosensors · doi:10.3390/bios12121167 · Cited by 66
“[39] used implantable BCI for the first time to enable quadriplegic patients to drive computer screen cursors and activate simple robotic devices just by thinking.”
MethodZhang, J., Li, J., Huang, Z., Huang, D., Yu, H., & Li, Z. (2023) · Health Data Science · doi:10.34133/hds.0096 · Cited by 76
“At present, invasive BCIs have been applied in motion control [3–6], disease diagnosis and treatment [7–9], communication assistance [10–13], cursor control [14–16], and other aspects.”
MethodBrain–computer interfaces: an overview of the hardware to record neural signals from the cortex
Stieglitz, T., Rubehn, B., Henle, C., Kisban, S., Herwik, S., Ruther, P., & Schüettler, M. (2009) · Progress in brain research · doi:10.1016/s0079-6123(09)17521-0 · Cited by 72
“In the last years, the knowledge about movement encoding could be used to control motor BCI in animal experiments (Schwartz et al., 2006) and also in an investigator study in a single paralyzed person (Hochberg et al., 2006).”
BackgroundCharacterizing Learning by Simultaneous Analysis of Continuous and Binary Measures of Performance
Prerau, M. J., Smith, A. C., Eden, U. T., Kubota, Y., Yanike, M., SUZUKI, W. A., Graybiel, A. M., & Brown, E. N. (2009) · Journal of Neurophysiology · doi:10.1152/jn.91251.2008 · Cited by 67
“Such algorithms could also make it possible to use simultaneously recorded ensemble neural spiking activity and local field potentials to improve control of neural prosthetic devices and brain machine interfaces (Hochberg et al. 2006; Srinivasan et al. 2007).”
BackgroundEthical issues in neuroprosthetics
Glannon, W. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/021002 · Cited by 59
“In a study involving two volunteers with tetraplegia from brainstem strokes, the system enabled one of the volunteers to grab a foam ball with the arm with a fairly high rate of success (Hochberg et al 2006, 2012).”
BackgroundSchalk, G. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/1/p01 · Cited by 62
Flavopiridol reduces the impedance of neural prostheses in vivo without affecting recording quality
Purcell, E. K., Thompson, D. E., Ludwig, K. A., & Kipke, D. R. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.06.026 · Cited by 62
Defining Surgical Terminology and Risk for Brain Computer Interface Technologies
Leuthardt, E. C., Moran, D. W., & Mullen, T. R. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.599549 · Cited by 71
“…highly resolved information about cognitive operations (e.g., complex motor kinematics) and can be both input and output BCIs (Taylor et al., 2002; Hochberg et al., 2006, 2012; Lebedev and Nicolelis, 2006; Hatsopoulos and Donoghue, 2009; Collinger et al., 2013; Flesher et al., 2016, 2017; Musk,…”
BackgroundClosed-loop stimulation using a multiregion brain-machine interface has analgesic effects in rodents
Sun, G., Zeng, F., McCartin, M., Zhang, Q., Xu, H., Liu, Y., Chen, Z. S., & Wang, J. (2022) · Science Translational Medicine · doi:10.1126/scitranslmed.abm5868 · Cited by 62
Vansteensel, M. J., Klein, E., van Thiel, G., Gaytant, M., Simmons, Z., Wolpaw, J. R., & Vaughan, T. M. (2023) · Journal of Neurology · doi:10.1007/s00415-022-11464-6 · Cited by 59
Closed-Loop Brain–Machine–Body Interfaces for Noninvasive Rehabilitation of Movement Disorders
Broccard, F. D., Mullen, T. R., Chi, Y. M., Peterson, D., Iversen, J. R., Arnold, M., Kreutz-Delgado, K., Jung, T., Makeig, S., Poizner, H., et al. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1032-6 · Cited by 68
Vourvopoulos, A., & Liarokapis, F. (2013) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2013.10.009 · Cited by 62
“For this reason environmental control BCI systems have been created the last few years [16,17] with promising results.”
BackgroundNanowire electrodes for high-density stimulation and measurement of neural circuits
Robinson, J. T., Jorgolli, M., & Park, H. (2013) · Frontiers in Neural Circuits · doi:10.3389/fncir.2013.00038 · Cited by 60
“For instance, contemporary extracellular electrodes have array sizes approaching one hundred electrodes and can simultaneously measure the activity of dozens of individual neurons (Hochberg et al., 2006; Donoghue et al., 2007; Du et al., 2011).”
BackgroundInfluentialLearning in Closed-Loop Brain–Machine Interfaces: Modeling and Experimental Validation
Héliot, R., Ganguly, K., Jimenez, J., & Carmena, J. M. (2010) · IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics) · doi:10.1109/tsmcb.2009.2036931 · Cited by 61
“In the experiment just described and, hence, in this simulation, a PVA (see [ 5 ] for details) was used to decode an endpoint velocity from neural firing rates.”
MethodInfluentialA cortical–spinal prosthesis for targeted limb movement in paralysed primate avatars
Shanechi, M. M., Hu, R. C., & Williams, Z. M. (2014) · Nature Communications · doi:10.1038/ncomms4237 · Cited by 58
Chaudhuri, R., He, B. J., & Wang, X. (2017) · Cerebral Cortex · doi:10.1093/cercor/bhx233 · Cited by 68
Li, F., Xia, Y., Wang, F., Zhang, D., Li, X., & He, F. (2020) · Applied Sciences · doi:10.3390/app10051804 · Cited by 64
“Therefore, BCI has a wide range of uses in patients with disabilities, such as patients with severe neuromuscular disease or interlocking symptoms [3,4].”
BackgroundSkousen, J. L., Bridge, M. J., & Tresco, P. A. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.08.039 · Cited by 61
Real-time estimation and biofeedback of single-neuron firing rates using local field potentials
Hall, T. M., Nazarpour, K., & Jackson, A. (2014) · Nature Communications · doi:10.1038/ncomms6462 · Cited by 61
“(3) At this stage it would be possible to project the LFP directly onto the six SRSP-PC axes to achieve dimensionality reduction.”
A High-Performance Keyboard Neural Prosthesis Enabled by Task Optimization
Nuyujukian, P., Fan, J. M., Kao, J. C., Ryu, S. I., & Shenoy, K. V. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2354697 · Cited by 60
Mental workload during brain–computer interface training
Felton, E. A., Williams, J. C., Vanderheiden, G. C., & Radwin, R. G. (2012) · Ergonomics · doi:10.1080/00140139.2012.662526 · Cited by 69
“2000, Hochberg et al .”
New approaches for CMOS-based devices for large-scale neural recording
Ruther, P., & Paul, O. (2015) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2014.10.007 · Cited by 62
“In contrast, the Utah array is limited to shaft lengths of a few millimeters due to the available thicknesses of silicon substrates.”
InfluentialCarpaneto, J., Umiltà, M. A., Fogassi, L., Murata, A., Gallese, V., Micera, S., & Raos, V. (2011) · Neuroscience · doi:10.1016/j.neuroscience.2011.04.062 · Cited by 64
Schwerdt, H. N., Xu, W., Shekhar, S., Abbaspour-Tamijani, A., Towe, B. C., Miranda, F. A., & Chae, J. (2011) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2011.2162487 · Cited by 61
“rooted in the CNS [4].”
A High-Sensitivity Fully Passive Neurosensing System for Wireless Brain Signal Monitoring
Lee, C. W. L., Kiourti, A., Chae, J., & Volakis, J. L. (2015) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2015.2421491 · Cited by 65
Neural Probes for Chronic Applications
Kook, G., Lee, S., Lee, H., Cho, I., & Lee, H. J. (2016) · Micromachines · doi:10.3390/mi7100179 · Cited by 69
“The first clinical report on successful cortical control of a prosthetic arm serves as an important hallmark in the neuroprosthetics field [6].”
BackgroundMillán, J. D. R. (2013) · Wiley eBooks · doi:10.1002/9781118628522.ch12 · Cited by 63
Brain–Machine Interface Control Algorithms
Shanechi, M. M. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2639501 · Cited by 61
“, [4]–[6], [9]–[22], [24]–[33]).”
BackgroundMethodInfluentialShen, W., Karumbaiah, L., Liu, X., Saxena, T., Chen, S., Patkar, R., Bellamkonda, R. V., & Allen, M. G. (2015) · Microsystems & Nanoengineering · doi:10.1038/micronano.2015.10 · Cited by 57
Suarez-Perez, A., Gabriel, G., Rebollo, B., Illa, X., Guimerà‐Brunet, A., Hernández‐Ferrer, J., Martínez, M. T., Villa, R., & Sanchez-Vives, M. V. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00862 · Cited by 65
Deep Learning Movement Intent Decoders Trained With Dataset Aggregation for Prosthetic Limb Control
Dantas, H., Warren, D. J., Wendelken, S., Davis, T. S., Clark, G. A., & Mathews, V. J. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2901882 · Cited by 64
“decoding algorithms fall into broad categories of Wiener filters [5], [6] population vectors [7], [8], probabilistic methods”
Electromyography Pattern-Recognition-Based Control of Powered Multifunctional Upper-Limb Prostheses
Li, G. (2011) · InTech eBooks · doi:10.5772/22876 · Cited by 67
“With BCI or PNI prosthetic control, neural sensors need to be directly connected to either the cortex or the residual nerves to capture the neural signals associated with arm movements as control signals of artificial neuroprostheses (DeLuca, 1978; Hoffer & Loeb, 1980; Edell, 1986; Hochberg et al., 2006).”
Wang, D., Zhang, Q., Li, Y., Wang, Y., Zhu, J., Zhang, S., & Zheng, X. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/036009 · Cited by 58
Grahn, P. J., Mallory, G. W., Berry, B. M., Hachmann, J. T., Lobel, D. A., & Luján, J. L. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00296 · Cited by 69
“…analyze, and decode brain signals (Wang et al., 2010) to infer volitional intent, which in turn can be used to control limb movement and assistive devices (Figure 2) (Leuthardt et al., 2004; Hochberg et al., 2006; Schwartz et al., 2006; Miller et al., 2010; Carmena, 2012; Fifer et al., 2012).”
MethodCorticospinal neuroprostheses to restore locomotion after spinal cord injury
Borton, D. A., Bonizzato, M., Beauparlant, J., DiGiovanna, J., Moraud, E. M., Wenger, N., Евгеньевич, М. П., Minev, I. R., Lacour, S. P., Millán, J. D. R., et al. (2013) · Neuroscience Research · doi:10.1016/j.neures.2013.10.001 · Cited by 62
Tooth-Click Control of a Hands-Free Computer Interface
Simpson, T., Broughton, C., Gauthier, M. J. A., & Prochazka, A. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.921161 · Cited by 56
Control of a vehicle with EEG signals in real-time and system evaluation
Choi, K. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2029-6 · Cited by 64
“In invasive BMI (Chapin et al. 1999; Carmena et al. 2003; Musallam et al. 2004; Hochberg et al. 2006; Choi et al. 2005, 2007), arm movement is mainly estimated from the firing rate of the neurons located in the primary motor cortex, which is the region related to arm movement, through a…”
BackgroundMethodBanville, H. J., & Falk, T. H. (2016) · Brain-Computer Interfaces · doi:10.1080/2326263x.2015.1134958 · Cited by 66
Bioelectronics with two-dimensional materials
Kang, P., Wang, M. C., & Nam, S. (2016) · Microelectronic Engineering · doi:10.1016/j.mee.2016.04.003 · Cited by 72
Hemicraniectomy: A New Model for Human Electrophysiology with High Spatio-temporal Resolution
Voytek, B., Secundo, L., Bidet‐Caulet, A., Scabini, D., Stiver, S. I., Gean, A. D., Manley, G. T., & Knight, R. T. (2010) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2009.21384 · Cited by 63
“Practically, researchers are making use of the improved signal from invasive recordings to drive brain–machine interface (BMI) devices to assist people with paralysis (Miller et al, 2007 ; Hochberg et al, 2006 ).”
BackgroundThe ethics of species: an introduction
(2013) · Choice Reviews Online · doi:10.5860/choice.50-5585 · Cited by 60
Alahi, M. E. E., Liu, Y., Xu, Z., Wang, H., Wu, T., & Mukhopadhyay, S. C. (2021) · Materials Today Communications · doi:10.1016/j.mtcomm.2021.102853 · Cited by 68
Ionic communication for implantable bioelectronics
Zhao, Z., Spyropoulos, G. D., Cea, C., Gelinas, J. N., & Khodagholy, D. (2022) · Science Advances · doi:10.1126/sciadv.abm7851 · Cited by 62
“For instance, brain-machine interfaces to enable control of assistive movement and communication devices in paralyzed patients require a chronically implanted, bulky, and rigid transcutaneous port that transmits high spatiotemporal resolution neural signals from a microelectrode array to external processors (28).”
Carbon nanotubes as substrates/scaffolds for neural cell growth
Lee, W., & Parpura, V. (2009) · Progress in brain research · doi:10.1016/s0079-6123(08)80006-4 · Cited by 60
“This should find use in brain–machine interfaces, which can be used to help understand brain function and restore the movement in tertraplegia (Hochberg et al., 2006; Schwartz, Cui, Weber, & Moran, 2006).”
BackgroundBrain–computer interfaces: a powerful tool for scientific inquiry
Wander, J. D., & Rao, R. P. N. (2014) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2013.11.013 · Cited by 66
Decoding the rat forelimb movement direction from epidural and intracortical field potentials
Slutzky, M. W., Jordan, L. R., Lindberg, E. W., Lindsay, K. E., & Miller, L. E. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036013 · Cited by 58
“However, current intracortical electrodes typically record single-unit spikes for no more than 1–3 years [21, 22].”
BackgroundPerformance predictors of brain–computer interfaces in patients with amyotrophic lateral sclerosis
Geronimo, A. M., Simmons, Z., & Schiff, S. J. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026002 · Cited by 70
Young, D., Willett, F., Memberg, W. D., Murphy, B., Walter, B., Sweet, J., Miller, J., Hochberg, L. R., Kirsch, R. F., & Ajiboye, A. B. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9ee8 · Cited by 61
Self-citationScherer, R., Zanos, S. P., Miller, K. J., Rao, R. P. N., & Ojemann, J. G. (2009) · Neurosurgical FOCUS · doi:10.3171/2009.4.focus0981 · Cited by 60
Error-related electrocorticographic activity in humans during continuous movements
Milekovic, T., Ball, T., Schulze-Bonhage, A., Aertsen, A., & Mehring, C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026007 · Cited by 57
“However, many powerful BMIs, such as the brain control of a prosthetic arm (Carmena et al 2003, Hochberg et al 2006, Velliste et al 2008) and the brain control of a computer cursor (Serruya et al 2002, Taylor et al 2002, Hochberg et al 2006) use continuous movement control of the effector.”
BackgroundPropagation of Epileptiform Activity on a Submillimeter Scale
Schevon, C. A., Goodman, R. R., McKhann, G., & Emerson, R. G. (2010) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e3181fdf8a1 · Cited by 57
“Single-neuron firing was detected using spike sorting software from Blackrock Microsystems, Inc. (Hochberg et al., 2006; Suner et al., 2005).”
Easily made single-walled carbon nanotube surface microelectrodes for neuronal applications
Gabriel, G., Gómez, R., Bongard, M., Benito, N., Fernández, E., & Villa, R. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.09.036 · Cited by 64
Shanechi, M. M., Wornell, G. W., Williams, Z. M., & Brown, E. N. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2221743 · Cited by 60
Implantable brain computer interface: Challenges to neurotechnology translation
Konrad, P. E., & Shanks, T. (2009) · Neurobiology of Disease · doi:10.1016/j.nbd.2009.12.007 · Cited by 61
Organic Bioelectronic Tools for Biomedical Applications
Löffler, S., Libberton, B., & Richter‐Dahlfors, A. (2015) · Electronics · doi:10.3390/electronics4040879 · Cited by 64
“brain computer interfaces, used to convey precise directions of movement [33,34], show great promise for development of robotic prostheses [35,36].”
BackgroundKernel-ARMA for Hand Tracking and Brain-Machine interfacing During 3D Motor Control
Shpigelman, L., Lalazar, H., & Vaadia, E. (2008) · neural information processing systems · Cited by 74
Brain–computer interfaces in the completely locked-in state and chronic stroke
Chaudhary, U., Birbaumer, N., & Ramos‐Murguialday, A. (2016) · Progress in brain research · doi:10.1016/bs.pbr.2016.04.019 · Cited by 67
Cutrone, A., & Micera, S. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801345 · Cited by 60
Learned motor patterns are replayed in human motor cortex during sleep
Rubin, D. B., Hosman, T., Kelemen, J. N., Kapitonava, A., Willett, F. R., Coughlin, B. F., Halgren, E., Kimchi, E. Y., Williams, Z. M., Simeral, J. D., et al. (2022) · The Journal of Neuroscience · doi:10.1523/jneurosci.2074-21.2022 · Cited by 57
“Details of the recording paradigm have been described previously (Hochberg et al., 2006, 2012; Malik et al., 2011; Eichenlaub et al., 2020).”
MethodSelf-citationAn Analysis of Deep Learning Models in SSVEP-Based BCI: A Survey
Xu, D., Tang, F., Li, Y., Zhang, Q., & Feng, X. (2023) · Brain Sciences · doi:10.3390/brainsci13030483 · Cited by 68
“BCIs allow users to harness their brain states for controlling devices such as spelling interfaces [2,3], wheelchairs [4,5], computer games [6,7], or other assistive devices [8,9].”
BackgroundMilekovic, T., Ball, T., Schulze‐Bonhage, A., Aertsen, A., & Mehring, C. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055235 · Cited by 63
“Most prominent examples are the BMI control of a prosthetic arm [1,8–10] and the brain control of a computer cursor [3,9,11].”
BackgroundVanDersarl, J. J., Mercanzini, A., & Renaud, P. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201402934 · Cited by 61
Graudejus, O., Yu, Z., Jones, J., Morrison, B., & Wagner, S. (2009) · Journal of The Electrochemical Society · doi:10.1149/1.3115465 · Cited by 58
Coating flexible probes with an ultra fast degrading polymer to aid in tissue insertion
Lo, M.-C., Wang, S., Singh, S., Damodaran, V. B., Kaplan, H. M., Kohn, J., Shreiber, D. I., & Zahn, J. D. (2015) · Biomedical Microdevices · doi:10.1007/s10544-015-9927-z · Cited by 53
“Brain computer interfaces (BCI) establish communication between the brain and external devices without transmission through peripheral neural pathways (Daly and Wolpaw 2008; Hochberg et al. 2006, 2012).”
BackgroundInterfacing With the Computational Brain
Jackson, A., & Fetz, E. E. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2158586 · Cited by 55
“The requirement for a training dataset presents a practical problem for ultimate clinical applications with paralyzed patients, although motor imagery may provide a suitable substitute for actual movement [19].”
BackgroundClosed-loop interaction with the cerebral cortex: a review of wireless implant technology
Kohler, F., Gkogkidis, C. A., Bentler, C., Wang, X., Gierthmuehlen, M., Fischer, J., Stolle, C., Reindl, L. M., Rickert, J., Stieglitz, T., et al. (2017) · Brain-Computer Interfaces · doi:10.1080/2326263x.2017.1338011 · Cited by 58
Predicting Motor Imagery Performance From Resting-State EEG Using Dynamic Causal Modeling
Lee, M., Yoon, J.-G., & Lee, S.-W. (2020) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2020.00321 · Cited by 63
Early interfaced neural activity from chronic amputated nerves
Garde, K. (2009) · Frontiers in Neuroengineering · doi:10.3389/neuro.16.005.2009 · Cited by 56
“Frontiers in Neuroengineering www.frontiersin.org May 2009 | Volume 2 | Article 5 | 1 NEUROENGINEERING ORIGINAL RESEARCH ARTICLE published: 26 May 2009 doi: 10.3389/neuro.16.005.2009 Early interfaced neural activity from chronic amputated nerves”
InfluentialMiall, R. C., Rosenthal, O., Ørstavik, K., Cole, J. D., & Sarlegna, F. R. (2019) · Experimental Brain Research · doi:10.1007/s00221-019-05583-2 · Cited by 57
“On the other hand, a challenge remains for bioengineers interested in developing prostheses, for instance, for amputees who complain about the lack of haptic feedback necessary for everyday actions with upper-limb prostheses (Hochberg et al. 2006; Aflalo et al. 2015; D’Anna et al. 2017).”
Pan, J., Chen, X., Ban, N., He, J., Chen, J., & Huang, H. (2022) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2022.1077717 · Cited by 66
“At present, BCI is used in many fields, including communication (Kennedy and Bakay, 1998; Hochberg et al., 2006), medical rehabilitation (Rohani and Puthusserypady, 2015), home automation (Corralejo et al., 2014; Park et al., 2015), and game entertainment (Leeb et al., 2013).”
MethodInvasive Brain Computer Interface for Motor Restoration in Spinal Cord Injury: A Systematic Review
Levett, J. J., Elkaim, L. M., Niazi, F., Weber, M. H., Iorio‐Morin, C., Bonizzato, M., & Weil, A. G. (2023) · Neuromodulation Technology at the Neural Interface · doi:10.1016/j.neurom.2023.10.006 · Cited by 74
Assessing the potential of electrodermal activity as an alternative access pathway
Blain, S., Mihailidis, A., & Chau, T. T. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.05.015 · Cited by 56
Felton, E. A., Radwin, R. G., Wilson, J. A., & Williams, J. C. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056002 · Cited by 62
“…studies have demonstrated that humans can operate a computer cursor using neural signals from the scalp (i.e. electroencephalogram or EEG) [12, 24, 26], the surface of the brain (i.e. electrocorticogram or ECoG) [6, 13] or within the brain (i.e. local field potentials and action potentials) [8, 10].”
BackgroundControlled delivery for neuro-bionic devices
Yue, Z., Moulton, S. E., Cook, M. J., O’Leary, S. J., & Wallace, G. G. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.06.002 · Cited by 61
“In a recent pilot clinical trial, patients with tetraplegia have shown to be able to control a computer's cursor and rudimentarily operate a multi-jointed robotic arm using the motor cortical signals recorded through an implanted 96-microelectrode array [15].”
BackgroundA hybrid silicon–parylene neural probe with locally flexible regions
Kim, E. G. R., John, J. K., Tu, H., Zheng, Q., Loeb, J. A., Zhang, J., & Xu, Y. P. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.01.048 · Cited by 66
Percepts to recollections: insights from single neuron recordings in the human brain
Suthana, N., & Fried, I. (2012) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2012.06.006 · Cited by 53
Proceedings of the Third International Workshop on Advances in Electrocorticography
Ritaccio, A., Beauchamp, M., Bosman, C., Brunner, P., Chang, E., Crone, N., Gunduz, A., Gupta, D., Knight, R., Leuthardt, E., et al. (2012) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2012.09.016 · Cited by 56
A Classification Algorithm for Electroencephalography Signals by Self-Induced Emotional Stimuli
Iacoviello, D., Petracca, A., Spezialetti, M., & Placidi, G. (2015) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2015.2498974 · Cited by 60
“In fact, in the last ten years BCI has revealed its potentialities for severely disabled and locked-in individuals who had very few possibilities to interact with the ambient and with other subjects [9]–[11].”
BackgroundInner speech in motor cortex and implications for speech neuroprostheses
Kunz, E. M., Abramovich Krasa, B., Kamdar, F., Avansino, D. T., Hahn, N., Yoon, S., Singh, A., Nason-Tomaszewski, S. R., Card, N. S., Jude, J. J., et al. (2025) · Cell · doi:10.1016/j.cell.2025.06.015 · Cited by 55
Self-citationTremblay, S., Doucet, G., Pieper, F., Sachs, A. J., & Martínez-Trujillo, J. (2015) · Journal of Neuroscience · doi:10.1523/jneurosci.1041-15.2015 · Cited by 57
“High degree-of-freedom control signals for these prosthetics can be extracted directly from neural spiking activity using chronic intracranial implants over motor and premotor cortical areas (Hochberg et al., 2006).”
BackgroundHuo, X., Wang, J., & Ghovanloo, M. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.06.0096 · Cited by 60
“More recently, invasive brain-computer interfaces (BCIs) have emerged based on subdural electrocorticograms or intracortical neural recording [12–15].”
MethodKim, J., Park, H., Bruce, J. A., Rowles, D. M., Holbrook, J. S., Nardone, B., West, D. P., Laumann, A. E., Roth, E. J., & Ghovanloo, M. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2405072 · Cited by 55
“For instance, BCIs are useful to those with high levels of paralysis [5], [6], but they are prone to motion artifacts and interference, and cannot be easily adapted to daily activities [7].”
BackgroundStanden, P., Camm, C., Battersby, S., Brown, D. J., & Harrison, M. J. (2010) · Computers & Education · doi:10.1016/j.compedu.2010.06.003 · Cited by 55
“More recently, Hochberg et al. (2006) implanted a 96 microelectrode array in the primary motor cortex which allowed a patient with tetraplegia to control the position of the cursor on a computer screen.”
BackgroundGoal selection versus process control in a brain–computer interface based on sensorimotor rhythms
Royer, A. S., & He, B. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/1/016005 · Cited by 58
“Both Hochberg et al (2006) and Hinterberger et al (2005) posited that feedback improves BCI performance.”
Creating new functional circuits for action via brain-machine interfaces
Orsborn, A. L., & Carmena, J. M. (2013) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2013.00157 · Cited by 59
“…including virtual objects (Serruya et al., 2002; Taylor et al., 2002; Carmena et al., 2003; Leuthardt et al., 2004; Wolpaw and McFarland, 2004; Hochberg et al., 2006; Jarosiewicz et al., 2008; Kim et al., 2008; Schalk et al., 2008; Ganguly and Carmena, 2009; Suminski et al., 2010; O’Doherty…”
BackgroundMethodMalaga, K. A., Schroeder, K. E., Patel, P. R., Irwin, Z. T., Thompson, D. E., Nicole Bentley, J., Lempka, S. F., Chestek, C. A., & Patil, P. G. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/1/016010 · Cited by 55
Perel, S., Sadtler, P. T., Oby, E. R., Ryu, S. I., Tyler-Kabara, E. C., Batista, A. P., & Chase, S. M. (2015) · Journal of Neurophysiology · doi:10.1152/jn.00293.2014 · Cited by 52
“…use recorded neural signals to actuate some device, such as a computer cursor (Taylor et al. 2002; Suminski et al. 2009; Ganguly and Carmena 2009; Hochberg et al. 2006; Mulliken et al. 2008; Schalk et al. 2007; Gilja et al. 2012; Ifft et al. 2013), robotic arm (Collinger et al. 2013; Hochberg et…”
BackgroundMethodInterfacing to the brain’s motor decisions
Mirabella, G., & Lebedev, M. (2016) · Journal of Neurophysiology · doi:10.1152/jn.00051.2016 · Cited by 57
“The rise in the number of human studies on invasive BMIs (Aflalo et al. 2015; Bouton et al. 2016; Collinger et al. 2013; Hochberg et al. 2006; Hochberg et al. 2012; Jarosiewicz et al. 2015) is particularly promising in this regard because invasive recordings and relevant BMI applications could…”
BackgroundInfluentialNonlinear effect of biological feedback on brain attentional state
Александрович, М. В., Hramov, A. E., Grubov, V., Nedaivozov, V. O., Makarov, V. V., & Pisarchik, A. N. (2018) · Nonlinear Dynamics · doi:10.1007/s11071-018-4668-1 · Cited by 56
A Synthesis of the Many Errors and Learning Processes of Visuomotor AdaptationPreprint
Morehead, J. R., & de Xivry, J. O. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.03.14.435278 · Cited by 60
“These techniques record neural activity directly and use it as an electronic control input (Fetz 1969; Vidal 1973) to interact directly with computers, robotic limbs or other devices (Carmena et al. 2003; Hochberg et al. 2006, 2012; Velliste et al. 2008).”
MethodComputing Arm Movements with a Monkey Brainet
Ramakrishnan, A., Ifft, P. J., Pais-Vieira, M., Byun, Y. W., Zhuang, K. Z., Lebedev, M. A., & Nicolelis, M. A. L. (2015) · Scientific Reports · doi:10.1038/srep10767 · Cited by 54
“To assess the performance of the B2 in manual control and brain control modes, we also calculated performance metrics reported in the previous literature 39,40 .”
Method
Metadata
- Authors
- Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P.
- Affiliations
- Brigham and Women's Hospital (US)
- Brown University (US)
- Cyberkinetics (United States) (US)
- Shirley Ryan AbilityLab (US)
- University of Chicago (US)
- Corresponding author
- Donoghue, John P.
- Venue
- Nature
- Published
- 2006-07
- Volume
- 442
- Issue
- 7099
- Pages
- 164-171
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2114004602
- Cited by
- 3,295
- References
- 47
- Citations by year
- 2026: 63 · 2025: 131 · 2024: 113 · 2023: 117 · 2022: 119 · 2021: 158 · 2020: 129 · 2019: 150 · 2018: 150 · 2017: 143 · 2016: 186 · 2015: 169 · 2014: 226 · 2013: 231 · 2012: 199
- FWCI
- 93.11
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Keywords
- tetraplegia, spinal cord injury, brain-computer interface, neuronal ensembles, primary motor cortex, intracortical microelectrode arrays, prosthetic hand control, robotic arm control, movement intention decoding, cervical spinal cord injury, upper limb paralysis
- MeSH terms
- Adult, Bionics, Electrodes, Humans, Male, Middle Aged, Movement, Quadriplegia, Robotics, User-Computer Interface, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.