Neuronal ensemble control of prosthetic devices by a human with tetraplegia
The DOI matches its Crossref record; 46 of the 47 references it cites were found in a registry or an index.
Abstract
Neuromotor prostheses (NMPs) aim to replace or restore lost motor functions in paralysed humans by routeing movement-related signals from the brain, around damaged parts of the nervous system, to external effectors. To translate preclinical results from intact animals to a clinically useful NMP, movement signals must persist in cortex after spinal cord injury and be engaged by movement intent when sensory inputs and limb movement are long absent. Furthermore, NMPs would require that intention-driven neuronal activity be converted into a control signal that enables useful tasks. Here we show initial results for a tetraplegic human (MN) using a pilot NMP. Neuronal ensemble activity recorded through a 96-microelectrode array implanted in primary motor cortex demonstrated that intended hand motion modulates cortical spiking patterns three years after spinal cord injury. Decoders were created, providing a 'neural cursor' with which MN opened simulated e-mail and operated devices such as a television, even while conversing. Furthermore, MN used neural control to open and close a prosthetic hand, and perform rudimentary actions with a multi-jointed robotic arm. These early results suggest that NMPs based upon intracortical neuronal ensemble spiking activity could provide a valuable new neurotechnology to restore independence for humans with paralysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Subcutaneous invasive electrophysiological signals can be derived through brain interfaces,[270–272] using electrocorticography (ECoG)[273,274] on the cortical surface as well as local field potentials (LFP)[275,276] extracted from electrodes inserted into the cortex.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [276]
In the citing paper
“Currently, all reported BMI experiments with human patients [26, 35, 57, 58, 150] require the subjects tethered percutaneously to a bench-top computer for neural signal acquisition and decoding.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [57]
In the citing paper
“Additionally, it is apparent from previous work that access to sufficiently large patient populations for concrete and statistically significant conclusions may be difficult to obtain (1–5, 8, 11, 29, 39).”
From Noninvasive neuroimaging enhances continuous neural tracking for robotic device control (2019) · cites this paper as [29]
Citations
Cites
Plum, F. (1960) · Archives of Neurology · doi:10.1001/archneur.1960.03840090124020 · Cited by 10,364
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Georgopoulos, A., Kalaska, J., Caminiti, R., & Massey, J. (1982) · The Journal of Neuroscience · doi:10.1523/jneurosci.02-11-01527.1982 · Cited by 2,130
International Standards for Neurological and Functional Classification of Spinal Cord Injury
Maynard, F. M., Bracken, M. B., Creasey, G., Jr, J. F. D., Donovan, W. H., Ducker, T. B., Garber, S. L., Marino, R. J., Stover, S. L., Tator, C. H., et al. (1997) · Spinal Cord · doi:10.1038/sj.sc.3100432 · Cited by 2,048
Advances in Neural Information Processing Systems 18
Murray, I., Mackay, D., Zoubin Ghahramani, A., & Skilling, J. (2006) · Cited by 1,927
Localization of the motor hand area to a knob on the precentral gyrus. A new landmark
Yousry, T. (1997) · Brain · doi:10.1093/brain/120.1.141 · Cited by 1,837
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Ditunno, J. F., Young, W., Donovan, W. H., & Creasey, G. (1994) · Spinal Cord · doi:10.1038/sc.1994.13 · Cited by 1,643
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Cited by
Items 1,001–1,022 of 1,022
Normann, R. A., Dowden, B. R., Frankel, M. A., Wilder, A. M., Hiatt, S. D., Ledbetter, N. M., Warren, D. A., & Clark, G. A. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026019 · Cited by 37
“of years [46, 47].”
Sharma, A., Rieth, L., Tathireddy, P., Harrison, R., Oppermann, H., Klein, M., Töpper, M., Jung, E., Normann, R., Clark, G., et al. (2012) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2011.11.015 · Cited by 35
“INTRODUCTION Implantable biomedical devices such as microelectrode arrays for neural recording/stimulation are being developed as viable treatments for sensory and movement disorders [1-3].”
BackgroundPels, E. G. M., Aarnoutse, E. J., Ramsey, N. F., & Vansteensel, M. J. (2017) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968317714577 · Cited by 33
The Layer 7 Cortical Interface: A Scalable and Minimally Invasive Brain–Computer Interface Platform
Hettick, M., Ho, E., Poole, A. J., Monge, M., Papageorgiou, D., Takahashi, K., LaMarca, M., Trietsch, D., Reed, K., Murphy, M., et al. (2022) · doi:10.1101/2022.01.02.474656 · Cited by 31
“The architecture comprises four consecutive 2D convolutional layers, each with increasing numbers of filters (8, 16, 32, 64) and a kernel size of 3 × 3 with “same” padding.”
BackgroundThe Emergence of Functional Ultrasound for Noninvasive Brain–Computer Interface
Zheng, H., Niu, L., Qiu, W., Liang, D., Long, X., Li, G., Liu, Z., & Meng, L. (2023) · Research · doi:10.34133/research.0200 · Cited by 27
“[1] indicated that a 96-microelectrode array implanted in primary motor cortex could provide a valuable new neurotechnology to restore independence for paralyzed patient.”
Physically interactive robotic technology for neuromotor rehabilitation
Hogan, N., & Krebs, H. I. (2011) · Progress in Brain Research · doi:10.1016/b978-0-444-53355-5.00004-x · Cited by 26
Toward Optimal Target Placement for Neural Prosthetic Devices
Cunningham, J. P., Yu, B. M., Gilja, V., Ryu, S. I., & Shenoy, K. V. (2008) · Journal of Neurophysiology · doi:10.1152/jn.90833.2008 · Cited by 25
Speech-related dorsal motor cortex activity does not interfere with iBCI cursor control
Stavisky, S. D., Willett, F. R., Avansino, D. T., Hochberg, L. R., Shenoy, K. V., & Henderson, J. M. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab5b72 · Cited by 25
Self-citationAlgorithm and hardware considerations for real-time neural signal on-implant processing
Zhang, Z., Savolainen, O. W., & Constandinou, T. G. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac5268 · Cited by 25
“Conventional decoding approaches are adaptive filters like the Wiener filter [39], Wiener cascade filter [40], Kalman filter [41] and unscented Kalman filter [42].”
MethodA Low Noise Amplifier for Neural Spike Recording Interfaces
Ruiz-Amaya, J., Rodriguez-Perez, A., & Delgado-Restituto, M. (2015) · Sensors · doi:10.3390/s151025313 · Cited by 23
“The information acquired by these interfaces can be used for the prevention and treatment of many neural diseases, as well as in Brain Machine Interfaces (BMIs) [22–24].”
MethodComparative analysis of energy transfer mechanisms for neural implants
Miziev, S., Pawlak, W. A., & Howard, N. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1320441 · Cited by 21
Nakayama, K., Moher, J., & Song, J.-H. (2023) · Annual Review of Psychology · doi:10.1146/annurev-psych-021422-043229 · Cited by 21
Tankus, A., Solomon, L., Aharony, Y., Faust-Socher, A., & Strauss, I. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac3315 · Cited by 20
A low-profile three-dimensional neural probe array using a silicon lead transfer structure
Cheng, M.-Y., Je, M., Tan, K. L., Tan, E. L., Lim, R., Yao, L., Li, P., Park, W.-T., Phua, E. J. R., Gan, C. L., et al. (2013) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/23/9/095013 · Cited by 18
“Recent studies [1, 2] have shown that quadriplegic patients or monkeys can consciously control the activity of neurons in”
BackgroundWillett, F. R., Murphy, B. A., Memberg, W. D., Blabe, C. H., Pandarinath, C., Walter, B. L., Sweet, J. A., Miller, J. P., Henderson, J. M., Shenoy, K. V., et al. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa5990 · Cited by 16
Self-citationGeorgiev, D. (2007) · NeuroQuantology · doi:10.14704/nq.2007.5.1.121 · Cited by 16
“Thought control of computer linked to the brain cortex of paraplegic human through machine-brain interface has been achieved by Hochberg et al. (2006) and the method remains the only possibility to restore the independence for humans with paralysis.”
BackgroundApplying the IEEE BRAIN neuroethics framework to intra-cortical brain-computer interfaces
Soldado-Magraner, J., Antonietti, A., French, J., Higgins, N., Young, M. J., Larrivee, D., & Monteleone, R. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad3852 · Cited by 16
“However, it was not only until the early 2000s that the first example of reliable multi-dimensional cursor control using a population of motor cortex neurons was reported in a human with tetraplegia [1, 24].”
Biotolerability of Intracortical Microelectrodes
Fernández, E., & Botella, P. (2018) · Advanced Biosystems · doi:10.1002/adbi.201700115 · Cited by 11
Frederick, R. A., Troyk, P. R., & Cogan, S. F. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac2bb8 · Cited by 7
“Human trials have successfully utilized intraneural microelectrode arrays for recording in cortex [4] and stimulation in peripheral nerves [5].”
Implantable Device Fabrication and Packaging
Stieglitz, T. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_102 · Cited by 7
Design and Microfabrication Considerations for Reliable Flexible Intracortical Implants
Sohal, H. S., Vassilevski, K., Jackson, A., Baker, S. N., & O’Neill, A. (2016) · Frontiers in Mechanical Engineering · doi:10.3389/fmech.2016.00005 · Cited by 4
“Also parylene-C has obtained the highest biocompatibility rating; class VI, from the United States Pharmacopeia (USP)[1,32].”
BackgroundWhen the ostrich-algorithm fails: blanking method affects spike train statistics.
Joseph, K., Mottaghi, S., Christ, O., Feuerstein, T. J., & Hofmann, U. G. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00293 · Cited by 3
Metadata
- Authors
- Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P.
- Affiliations
- Brigham and Women's Hospital (US)
- Brown University (US)
- Cyberkinetics (United States) (US)
- Shirley Ryan AbilityLab (US)
- University of Chicago (US)
- Corresponding author
- Donoghue, John P.
- Venue
- Nature
- Published
- 2006-07
- Volume
- 442
- Issue
- 7099
- Pages
- 164-171
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2114004602
- Cited by
- 3,295
- References
- 47
- Citations by year
- 2026: 63 · 2025: 131 · 2024: 113 · 2023: 117 · 2022: 119 · 2021: 158 · 2020: 129 · 2019: 150 · 2018: 150 · 2017: 143 · 2016: 186 · 2015: 169 · 2014: 226 · 2013: 231 · 2012: 199
- FWCI
- 93.11
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Keywords
- tetraplegia, spinal cord injury, brain-computer interface, neuronal ensembles, primary motor cortex, intracortical microelectrode arrays, prosthetic hand control, robotic arm control, movement intention decoding, cervical spinal cord injury, upper limb paralysis
- MeSH terms
- Adult, Bionics, Electrodes, Humans, Male, Middle Aged, Movement, Quadriplegia, Robotics, User-Computer Interface, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.