Neuronal ensemble control of prosthetic devices by a human with tetraplegia
The DOI matches its Crossref record; 46 of the 47 references it cites were found in a registry or an index.
Abstract
Neuromotor prostheses (NMPs) aim to replace or restore lost motor functions in paralysed humans by routeing movement-related signals from the brain, around damaged parts of the nervous system, to external effectors. To translate preclinical results from intact animals to a clinically useful NMP, movement signals must persist in cortex after spinal cord injury and be engaged by movement intent when sensory inputs and limb movement are long absent. Furthermore, NMPs would require that intention-driven neuronal activity be converted into a control signal that enables useful tasks. Here we show initial results for a tetraplegic human (MN) using a pilot NMP. Neuronal ensemble activity recorded through a 96-microelectrode array implanted in primary motor cortex demonstrated that intended hand motion modulates cortical spiking patterns three years after spinal cord injury. Decoders were created, providing a 'neural cursor' with which MN opened simulated e-mail and operated devices such as a television, even while conversing. Furthermore, MN used neural control to open and close a prosthetic hand, and perform rudimentary actions with a multi-jointed robotic arm. These early results suggest that NMPs based upon intracortical neuronal ensemble spiking activity could provide a valuable new neurotechnology to restore independence for humans with paralysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Subcutaneous invasive electrophysiological signals can be derived through brain interfaces,[270–272] using electrocorticography (ECoG)[273,274] on the cortical surface as well as local field potentials (LFP)[275,276] extracted from electrodes inserted into the cortex.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [276]
In the citing paper
“Currently, all reported BMI experiments with human patients [26, 35, 57, 58, 150] require the subjects tethered percutaneously to a bench-top computer for neural signal acquisition and decoding.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [57]
In the citing paper
“Additionally, it is apparent from previous work that access to sufficiently large patient populations for concrete and statistically significant conclusions may be difficult to obtain (1–5, 8, 11, 29, 39).”
From Noninvasive neuroimaging enhances continuous neural tracking for robotic device control (2019) · cites this paper as [29]
Citations
Cites
Plum, F. (1960) · Archives of Neurology · doi:10.1001/archneur.1960.03840090124020 · Cited by 10,364
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Georgopoulos, A., Kalaska, J., Caminiti, R., & Massey, J. (1982) · The Journal of Neuroscience · doi:10.1523/jneurosci.02-11-01527.1982 · Cited by 2,130
International Standards for Neurological and Functional Classification of Spinal Cord Injury
Maynard, F. M., Bracken, M. B., Creasey, G., Jr, J. F. D., Donovan, W. H., Ducker, T. B., Garber, S. L., Marino, R. J., Stover, S. L., Tator, C. H., et al. (1997) · Spinal Cord · doi:10.1038/sj.sc.3100432 · Cited by 2,048
Advances in Neural Information Processing Systems 18
Murray, I., Mackay, D., Zoubin Ghahramani, A., & Skilling, J. (2006) · Cited by 1,927
Localization of the motor hand area to a knob on the precentral gyrus. A new landmark
Yousry, T. (1997) · Brain · doi:10.1093/brain/120.1.141 · Cited by 1,837
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Ditunno, J. F., Young, W., Donovan, W. H., & Creasey, G. (1994) · Spinal Cord · doi:10.1038/sc.1994.13 · Cited by 1,643
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Cited by
Items 101–200 of 1,022
Organic electronics for precise delivery of neurotransmitters to modulate mammalian sensory function
Simon, D. T., Kurup, S., Larsson, K. C., Hori, R., Tybrandt, K., Goiny, M., Jager, E. W. H., Berggren, M., Canlon, B., & Richter-Dahlfors, A. (2009) · Nature Materials · doi:10.1038/nmat2494 · Cited by 349
Oxley, T. J., Opie, N. L., John, S. E., Rind, G. S., Ronayne, S. M., Wheeler, T. L., Judy, J. W., McDonald, A. J., Dornom, A., Lovell, T. J. H., et al. (2016) · Nature Biotechnology · doi:10.1038/nbt.3428 · Cited by 339
Brain–machine interfaces in neurorehabilitation of stroke
Soekadar, S. R., Birbaumer, N., Slutzky, M. W., & Cohen, L. G. (2015) · Neurobiology of Disease · doi:10.1016/j.nbd.2014.11.025 · Cited by 335
“By substituting for lost motor functions, such assistive BMIs have demonstrated recovery of versatile motor control in daily life activities (Hochberg et al., 2006; Collinger et al., 2013).”
Brain–computer interfaces as new brain output pathways
Wolpaw, J. R. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.125948 · Cited by 348
“The similarity is strikingly illustrated by comparing the videos available at http:// www.bciresearch.org/html/2d control 8tn.html (Wolpaw & McFarland, 2004) and http://www.nature.com/nature/ journal/v442/n7099/suppinfo/nature04970.html (video 1) (Hochberg et al. 2006).”
BackgroundMethodChallenges and opportunities for large-scale electrophysiology with Neuropixels probes
Steinmetz, N. A., Koch, C., Harris, K. D., & Carandini, M. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.01.009 · Cited by 333
Chestek, C. A., Gilja, V., Nuyujukian, P., Foster, J. D., Fan, J. M., Kaufman, M. T., Churchland, M. M., Rivera-Alvidrez, Z., Cunningham, J. P., Ryu, S. I., et al. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/045005 · Cited by 350
Upper limb amputees can be induced to experience a rubber hand as their own
Ehrsson, H. H., Rosen, B., Stockselius, A., Ragno, C., Kohler, P., & Lundborg, G. (2008) · Brain · doi:10.1093/brain/awn297 · Cited by 343
“A major area of research is dedicated to learning how to control the movements of artificial limbs using signals recorded directly from populations of cortical neurons (Nicolelis, 2003; Schwartz, 2004; Hochberg et al., 2006; Lebedev and Nicolelis, 2006; Velliste et al., 2008), signals originating from the nerves (Nava…”
BackgroundSLM microscopy: scanless two-photon imaging and photostimulation using spatial light modulators
Nikolenko, V. (2008) · Frontiers in Neural Circuits · doi:10.3389/neuro.04.005.2008 · Cited by 340
Clinical translation of a high-performance neural prosthesis
Gilja, V., Pandarinath, C., Blabe, C. H., Nuyujukian, P., Simeral, J. D., Sarma, A. A., Sorice, B. L., Perge, J. A., Jarosiewicz, B., Hochberg, L. R., et al. (2015) · Nature Medicine · doi:10.1038/nm.3953 · Cited by 343
Self-citationMicroelectrodes, Microelectronics, and Implantable Neural Microsystems
Wise, K. D., Sodagar, A. M., Yao, Y., Gulari, M. N., Perlin, G. E., & Najafi, K. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922564 · Cited by 335
Jarosiewicz, B., Sarma, A. A., Bacher, D., Masse, N. Y., Simeral, J. D., Sorice, B., Oakley, E. M., Blabe, C., Pandarinath, C., Gilja, V., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aac7328 · Cited by 340
Self-citationDesign of a cybernetic hand for perception and action
Carrozza, M. C., Cappiello, G., Micera, S., Edin, B. B., Beccai, L., & Cipriani, C. (2006) · Biological Cybernetics · doi:10.1007/s00422-006-0124-2 · Cited by 341
“Central invasive neural interfaces have been used by many groups (Carmena et al. 2003; Serruya et al. 2002; Musallam et al. 2004; Taylor et al. 2002; Hochberg et al. 2006; Schwartz 2004) to extract motor information related to reaching movements.”
MethodPrediction of arm movement trajectories from ECoG-recordings in humans
Pistohl, T., Ball, T., Schulze-Bonhage, A., Aertsen, A., & Mehring, C. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.10.001 · Cited by 331
“Invasive recording techniques with intracortical icroelectrodes have mainly been used in animal experiments Serruya et al., 2002; Taylor et al., 2002; Carmena et al., 2003), n some cases also in human experiments (Kennedy et al., 2004; ochberg et al., 2006).”
MethodThe brain–computer interface cycle
Gerven, M. V., Farquhar, J., Schaefer, R., Vlek, R., Geuze, J., Nijholt, A., Ramsey, N., Haselager, P., Vuurpijl, L., Gielen, S., et al. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/041001 · Cited by 329
“This technique started with monkeys [5, 38], but has recently been used successfully in human subjects [39].”
MethodNon-invasive brain–computer interface system: Towards its application as assistive technology
Cincotti, F., Mattia, D., Aloise, F., Bufalari, S., Schalk, G., Oriolo, G., Cherubini, A., Marciani, M. G., & Babiloni, F. (2008) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2008.01.007 · Cited by 323
The Design of Integrated Circuits to Observe Brain Activity
Harrison, R. R. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922581 · Cited by 330
Brain–Computer Interfaces: A Gentle Introduction
Graimann, B., Allison, B., & Pfurtscheller, G. (2009) · The Frontiers Collection · doi:10.1007/978-3-642-02091-9_1 · Cited by 298
An implantable wireless neural interface for recording cortical circuit dynamics in moving primates
Borton, D. A., Yin, M., Aceros, J., & Nurmikko, A. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026010 · Cited by 321
Ragnarsson, K. T. (2008) · Spinal Cord · doi:10.1038/sj.sc.3102091 · Cited by 301
Liu, G., Chang, C., Qiao, Z., Wu, K., Zhu, Z., Cui, G., Peng, W., Tang, Y., Li, J., & Fan, C. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201807862 · Cited by 318
Davis, T. S., Wark, H. A. C., Hutchinson, D. T., Warren, D. J., O’Neill, K., Scheinblum, T., Clark, G. A., Normann, R. A., & Greger, B. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036001 · Cited by 314
A Wireless Brain-Machine Interface for Real-Time Speech Synthesis
Guenther, F. H., Brumberg, J. S., Wright, E. J., Nieto-Castanon, A., Tourville, J. A., Panko, M., Law, R., Siebert, S. A., Bartels, J. L., Andreasen, D. S., et al. (2009) · PLoS ONE · doi:10.1371/journal.pone.0008218 · Cited by 306
“These results generalize previous findings of successful motor learning for control of a computer cursor by paralyzed humans with implants in the hand/arm area of motor cortex [29,30,32–34], an ability previously demonstrated in monkey BMI studies [35–37], to the domain of speech production.”
Predicting Movement from Multiunit Activity
Stark, E., & Abeles, M. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.1321-07.2007 · Cited by 309
“Considerable efforts are being made to decipher brain activity recorded with multiple electrodes, with an aim to replace malfunctioning organs (Wessberg et al., 2000; Serruya et al., 2002; Taylor et al., 2002; Carmena et al., 2003; Musallam et al., 2004; Hochberg et al., 2006).”
BackgroundInfluentialFunctional network reorganization during learning in a brain-computer interface paradigm
Jarosiewicz, B., Chase, S. M., Fraser, G. W., Velliste, M., Kass, R. E., & Schwartz, A. B. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0808113105 · Cited by 302
“the formula ( ) ( )(2) ˆ ˆ μ μ SE V = (15)”
An EEG-Based BCI System for 2-D Cursor Control by Combining Mu/Beta Rhythm and P300 Potential
Li, Y., Long, J., Yu, T., Yu, Z., Wang, C., Zhang, H., & Guan, C. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2055564 · Cited by 298
“BCIs have been invasive [14] or with expensive neuroimaging devices like magnetoencephalography [15].”
MethodBridging the Brain to the World: A Perspective on Neural Interface Systems
Donoghue, J. P. (2008) · Neuron · doi:10.1016/j.neuron.2008.10.037 · Cited by 294
“Pilot clinical studies have now further demonstrated that years after SCI or stroke, MI spiking as well as LFP activity remains and both signals can be immediately modulated by intention or attempts to move ( Hochberg et al., 2006; Truccolo et al., 2008).”
InfluentialSelf-citationPrasad, A., Xue, Q.-S., Sankar, V., Nishida, T., Shaw, G., Streit, W. J., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056015 · Cited by 298
Congruent Activity during Action and Action Observation in Motor Cortex
Tkach, D., Reimer, J., & Hatsopoulos, N. G. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.2895-07.2007 · Cited by 297
“At the single-cell level, observation-related MI activity has only been used to set the initial parameters for motor decoding schemes (Hochberg et al., 2006; Wahnoun et al., 2006), but the origin, extent, and character of this activity has not been described previously.”
BackgroundMethodRepairing the human brain after stroke. II. Restorative therapies
Cramer, S. C. (2008) · Annals of Neurology · doi:10.1002/ana.21412 · Cited by 285
Advanced Neurotechnologies for Chronic Neural Interfaces: New Horizons and Clinical Opportunities
Kipke, D. R., Shain, W., Buzsáki, G., Fetz, E., Henderson, J. M., Hetke, J. F., & Schalk, G. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.3879-08.2008 · Cited by 286
“…activity from neurons recorded within the brain (Georgopoulos et al., 1986; Serruya et al., 2002; Taylor et al., 2002; Shenoy et al., 2003; Andersen et al., 2004; Musallam et al., 2004; Lebedev et al., 2005; Hochberg et al., 2006; Santhanam et al., 2006; Lee et al., 2008; Velliste et al., 2008).”
BackgroundInfluentialDecoding flexion of individual fingers using electrocorticographic signals in humans
Kubánek, J., Miller, K. J., Ojemann, J. G., Wolpaw, J. R., & Schalk, G. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/6/066001 · Cited by 285
“Despite encouraging evidence that BCI technologies can actually be useful for severely disabled individuals [6, 23], these issues of non-invasive and action potential-based techniques in acquiring and maintaining robust recordings and BCI control remain crucial obstacles that currently impede widespread clinical use i…”
Large-scale neural recordings with single neuron resolution using Neuropixels probes in human cortex
Paulk, A. C., Kfir, Y., Khanna, A. R., Mustroph, M. L., Trautmann, E. M., Soper, D. J., Stavisky, S. D., Welkenhuysen, M., Dutta, B., Shenoy, K. V., et al. (2022) · Nature Neuroscience · doi:10.1038/s41593-021-00997-0 · Cited by 283
“These studies range in application from decoding handwriting and controlling prosthetic limbs and reanimating upper extremities to providing sensory feedback (via intracortical microstimulation) 19–24 .”
BackgroundSelf-citationFast and Slow Oscillations in Human Primary Motor Cortex Predict Oncoming Behaviorally Relevant Cues
Saleh, M., Reimer, J., Penn, R., Ojakangas, C. L., & Hatsopoulos, N. G. (2010) · Neuron · doi:10.1016/j.neuron.2010.02.001 · Cited by 281
“We had the unique opportunity to test these hypotheses in the knob area of the primary motor cortex of a tetraplegic individual with a BrainGate neuroprosthetic implant (Hochberg et al., 2006).”
BackgroundMethodInfluentialSelf-citationIn-cell recordings by extracellular microelectrodes
Hai, A., Shappir, J., & Spira, M. E. (2010) · Nature Methods · doi:10.1038/nmeth.1420 · Cited by 270
Brain–computer interface in paralysis
Birbaumer, N., Murguialday, A. R., & Cohen, L. (2008) · Current Opinion in Neurology · doi:10.1097/wco.0b013e328315ee2d · Cited by 275
Decoding Complete Reach and Grasp Actions from Local Primary Motor Cortex Populations
Vargas-Irwin, C. E., Shakhnarovich, G., Yadollahpour, P., Mislow, J. M. K., Black, M. J., & Donoghue, J. P. (2010) · Journal of Neuroscience · doi:10.1523/jneurosci.5443-09.2010 · Cited by 268
“Hochberg et al. (2006) showed that a person with tetraplegia was able to operate a 1D proportional control robotic hand and could use a 2D interface to perform reach and grasp with a simple robot arm.”
BackgroundInfluentialSelf-citationFlexible and stretchable micro-electrodes for in vitro and in vivo neural interfaces
Lacour, S. P., Benmerah, S., Tarte, E., FitzGerald, J., Serra, J., McMahon, S., Fawcett, J., Graudejus, O., Yu, Z., & Morrison, B. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0644-8 · Cited by 263
Kwak, N.-S., Müller, K.-R., & Lee, S.-W. (2017) · PLOS ONE · doi:10.1371/journal.pone.0172578 · Cited by 272
Brain–computer interface robotics for hand rehabilitation after stroke: a systematic review
Baniqued, P. D. E., Stanyer, E. C., Awais, M., Alazmani, A., Jackson, A. E., Mon-Williams, M. A., Mushtaq, F., & Holt, R. J. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00820-8 · Cited by 246
Volitional control of neural activity: implications for brain–computer interfaces
Fetz, E. E. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.127142 · Cited by 265
“For example, a paraplegic subject that could practise neural control of a cursor only several hours a week demonstrated remarkable success in controlling a cursor movement, but nevertheless achieved a limited degree of accuracy (Hochberg et al. 2006).”
BackgroundInfluentialBrain–computer interfaces for speech communication
Brumberg, J. S., Nieto-Castanon, A., Kennedy, P. R., & Guenther, F. H. (2010) · Speech Communication · doi:10.1016/j.specom.2010.01.001 · Cited by 267
“…2002; Velliste et al., 2008; Wessberg et al., 2000) and in some human volunteers (Bartels et al., 2008; Brumberg et al., 2009; Guenther et al., 2009; Hochberg et al., 2006; Kennedy et al., 2004; Kim et al., 2007) for experimental BCI investigations to restore artificial movement and communication.”
BackgroundMethodInfluentialProsthetic Myoelectric Control Strategies: A Clinical Perspective
Roche, A. D., Rehbaum, H., Farina, D., & Aszmann, O. C. (2014) · Current Surgery Reports · doi:10.1007/s40137-013-0044-8 · Cited by 261
“Peripheral nerve function has been shown to remain intact many years after amputation [87], and successful direct nerve recording systems have been demonstrated in amputees [80, 88, 89], as well as cortical recording in patients with spinal cord injuries [90, 91].”
BackgroundImproving data quality in neuronal population recordings
Harris, K. D., Quiroga, R. Q., Freeman, J., & Smith, S. L. (2016) · Nature Neuroscience · doi:10.1038/nn.4365 · Cited by 252
Primary Motor Cortex Tuning to Intended Movement Kinematics in Humans with Tetraplegia
Truccolo, W., Friehs, G. M., Donoghue, J. P., & Hochberg, L. R. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.4415-07.2008 · Cited by 272
“The filter building procedure has been described previously (Serruya et al., 2002; Hochberg et al., 2006a).”
BackgroundMethodInfluentialSelf-citationNeuromodulation for Brain Disorders: Challenges and Opportunities
Johnson, M. D., Lim, H. H., Netoff, T. I., Connolly, A. T., Johnson, N., Roy, A., Holt, A., Lim, K. O., Carey, J. R., Vitek, J. L., et al. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2244890 · Cited by 251
“Penetrating cortical electrodes have also been pioneered for clinical use in brain–machine interface applications [49], but have yet to be broadly used for clinical neuro-”
MethodAbidian, M. R., Ludwig, K. A., Marzullo, T. C., Martin, D. C., & Kipke, D. R. (2009) · Advanced Materials · doi:10.1002/adma.200900887 · Cited by 255
The Illusion of Owning a Third Arm
Guterstam, A., Petkova, V. I., & Ehrsson, H. H. (2011) · PLoS ONE · doi:10.1371/journal.pone.0017208 · Cited by 253
Real-time functional magnetic resonance imaging: methods and applications
Weiskopf, N., Sitaram, R., Josephs, O., Veit, R., Scharnowski, F., Goebel, R., Birbaumer, N., Deichmann, R., & Mathiak, K. (2007) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.02.007 · Cited by 253
“[2 recording brain activity (with few exceptions using invasive recordings [48] or other imaging techniques [49]).”
Dobkin, B. H. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.123067 · Cited by 256
“Intracortical strategies decode burst activity from a small number of neurons in the primary motor cortex (M1) or other regions via a multi-electrode array (Pomeroy et al. 2005; Hochberg et al. 2006).”
BackgroundReversible large-scale modification of cortical networks during neuroprosthetic control
Ganguly, K., Dimitrov, D. F., Wallis, J. D., & Carmena, J. M. (2011) · Nature Neuroscience · doi:10.1038/nn.2797 · Cited by 259
Neural interfaces for the brain and spinal cord—restoring motor function
Jackson, A., & Zimmermann, J. B. (2012) · Nature Reviews Neurology · doi:10.1038/nrneurol.2012.219 · Cited by 253
Upper limb movements can be decoded from the time-domain of low-frequency EEG
Ofner, P., Schwarz, A., Pereira, J., & Müller-Putz, G. R. (2017) · PLOS ONE · doi:10.1371/journal.pone.0182578 · Cited by 253
Electrocorticographic control of a prosthetic arm in paralyzed patients
Yanagisawa, T., Hirata, M., Saitoh, Y., Kishima, H., Matsushita, K., Goto, T., Fukuma, R., Yokoi, H., Kamitani, Y., & Yoshimine, T. (2012) · Annals of Neurology · doi:10.1002/ana.22613 · Cited by 256
Doud, A. J., Lucas, J. P., Pisansky, M. T., & He, B. (2011) · PLoS ONE · doi:10.1371/journal.pone.0026322 · Cited by 244
“Until recent years, sophisticated thought-based control of movement in multiple dimensions was relegated to the subcategory of invasive BCI systems [1,2,3,4,5,6,7].”
BackgroundA survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252
Liang, Y., Offenhäusser, A., Ingebrandt, S., & Mayer, D. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100061 · Cited by 239
The BRAIN Initiative: developing technology to catalyse neuroscience discovery
Jorgenson, L. A., Newsome, W. T., Anderson, D. J., Bargmann, C. I., Brown, E. N., Deisseroth, K., Donoghue, J. P., Hudson, K. L., Ling, G. S. F., MacLeish, P. R., et al. (2015) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2014.0164 · Cited by 238
“Implanted devices are being used in clinical practice to monitor brain function, to diagnose and treat mood and movement disorders, and to restore sensory and motor functions lost following injury or disease [61–65].”
BackgroundSelf-citationThe neural mechanisms of manual dexterity
Sobinov, A. R., & Bensmaia, S. J. (2021) · Nature Reviews Neuroscience · doi:10.1038/s41583-021-00528-7 · Cited by 248
Collective dynamics in human and monkey sensorimotor cortex: predicting single neuron spikes
Truccolo, W., Hochberg, L. R., & Donoghue, J. P. (2010) · Nature Neuroscience · doi:10.1038/nn.2455 · Cited by 255
Self-citationFunctional priorities, assistive technology, and brain-computer interfaces after spinal cord injury
Collinger, J. L., Boninger, M. L., Bruns, T. M., Curley, K., Wang, W., & Weber, D. J. (2013) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.11.0213 · Cited by 248
Andersen, R. A., Hwang, E. J., & Mulliken, G. H. (2010) · Annual Review of Psychology · doi:10.1146/annurev.psych.093008.100503 · Cited by 237
Perge, J. A., Homer, M. L., Malik, W. Q., Cash, S., Eskandar, E., Friehs, G., Donoghue, J. P., & Hochberg, L. R. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036004 · Cited by 243
Self-citationOxley, T. J., Yoo, P. E., Rind, G. S., Ronayne, S. M., Lee, C. M. S., Bird, C., Hampshire, V., Sharma, R. P., Morokoff, A., Williams, D. L., et al. (2021) · Journal of NeuroInterventional Surgery · doi:10.1136/neurintsurg-2020-016862 · Cited by 243
Self-citationWrigley, P. J., Gustin, S. M., Macey, P. M., Nash, P. G., Gandevia, S. C., Macefield, V. G., Siddall, P. J., & Henderson, L. A. (2009) · Cerebral Cortex · doi:10.1093/cercor/bhn072 · Cited by 238
Pei, X., Barbour, D. L., Leuthardt, E. C., & Schalk, G. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046028 · Cited by 237
Chandrakumar, H., & Markovic, D. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2645611 · Cited by 237
Brain–computer interface–based communication in the completely locked-in State
Chaudhary, U., Xia, B., Silvoni, S., Cohen, L. G., & Birbaumer, N. (2017) · PLOS Biology · doi:10.1371/journal.pbio.1002593 · Cited by 235
“Patients in those studies [10,11,41] still had intact motor control of eye movements and some remaining muscles and thus could use the remaining muscular forces (somatomotor mediation) for instrumental learning and BCI control.”
BackgroundRetractedDecoding spoken words using local field potentials recorded from the cortical surface
Kellis, S., Miller, K., Thomson, K., Brown, R., House, P., & Greger, B. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/5/056007 · Cited by 235
“These electrodes have been used to perform rapid decoding of continuous motor movements from neuronal activity in the primary motor area of human neocortex [6].”
MethodA novel algorithm for precise identification of spikes in extracellularly recorded neuronal signals
Maccione, A., Gandolfo, M., Massobrio, P., Novellino, A., Martinoia, S., & Chiappalone, M. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.09.026 · Cited by 233
Neurons in primary motor cortex engaged during action observation
Dushanova, J., & Donoghue, J. (2010) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2009.07067.x · Cited by 225
“More recently, it has been shown that M1 neurons are engaged in humans with paralysis who are explicitly rehearsing actions in the absence of purposeful movement (Hochberg et al., 2006; Truccolo et al., 2008).”
BackgroundMethodSelf-citationHybrid EEG–fNIRS-Based Eight-Command Decoding for BCI: Application to Quadcopter Control
Khan, M. J., & Hong, K.-S. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00006 · Cited by 227
“The complicated surgical procedures performed for microelectrode implantation and establishment of BCI have been outstandingly successful in achieving control of robotic and prosthetic arms by means of neuronal-signal acquisition (Hochberg et al., 2006, 2012).”
MethodNoninvasive Brain-Computer Interfaces Based on Sensorimotor Rhythms
He, B., Baxter, B., Edelman, B. J., Cline, C. C., & Ye, W. W. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2407272 · Cited by 233
“[4] L.”
Online Myoelectric Control of a Dexterous Hand Prosthesis by Transradial Amputees
Cipriani, C., Antfolk, C., Controzzi, M., Lundborg, G., Rosen, B., Carrozza, M. C., & Sebelius, F. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2108667 · Cited by 233
“While acquisition of invasive biosignals from the motor cortex may be suitable for tetraplegics [3], who have lost their ability to control the entirety of their upper limbs, and less invasive Online Myoelectric Control of a Dexterous Hand Prosthesis by Transradial Amputees”
BackgroundBrain-Computer Interface in Stroke: A Review of Progress
Silvoni, S., Ramos-Murguialday, A., Cavinato, M., Volpato, C., Cisotto, G., Turolla, A., Piccione, F., & Birbaumer, N. (2011) · Clinical EEG and Neuroscience · doi:10.1177/155005941104200410 · Cited by 223
(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-52901-5.00006-x · Cited by 212
Decoding Trajectories from Posterior Parietal Cortex Ensembles
Mulliken, G. H., Musallam, S., & Andersen, R. A. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.1463-08.2008 · Cited by 231
“…targeted multiple brain areas and signal types (Kennedy et al., 2000; Wessberg et al., 2000; Serruya et al., 2002; Taylor et al., 2002; Carmena et al., 2003; Shenoy et al., 2003; Musallam et al., 2004; Patil et al., 2004; Wolpaw and McFarland, 2004; Hochberg et al., 2006; Santhanam et al., 2006).”
BackgroundIncorporating Feedback from Multiple Sensory Modalities Enhances Brain–Machine Interface Control
Suminski, A. J., Tkach, D. C., Fagg, A. H., & Hatsopoulos, N. G. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.3967-10.2010 · Cited by 231
“…a decoder based on a linear filter because of its computational simplicity and its strong presence in the literature (Serruya et al., 2002; Taylor et al., 2002; Carmena et al., 2003; Musallam et al., 2004; Hochberg et al., 2006; Kim et al., 2008; Mulliken et al., 2008; Ganguly and Carmena, 2009).”
BackgroundMethodInfluentialFang, H., Zhao, J., Yu, K. J., Song, E., Farimani, A. B., Chiang, C.-H., Jin, X., Xue, Y., Xu, D., Du, W., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1605269113 · Cited by 225
“Extensions of these types of systems for use as chronic implants have the potential to improve capabilities in human health care across broad categories of disease states and disorders (23, 24).”
BackgroundSpeech synthesis from ECoG using densely connected 3D convolutional neural networks
Angrick, M., Herff, C., Mugler, E., Tate, M. C., Slutzky, M. W., Krusienski, D. J., & Schultz, T. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab0c59 · Cited by 225
“While our study uses overtly-produced speech in motor-intact participants, there are recent advances in decoding motor function [67, 68, 69, 70] in paralyzed patients that might be extended to the decoding of speech from motor areas in the future.”
BackgroundA lower limb exoskeleton control system based on steady state visual evoked potentials
Kwak, N.-S., Müller, K.-R., & Lee, S.-W. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/5/056009 · Cited by 221
Virtual Reality for Neurorehabilitation and Cognitive Enhancement
Georgiev, D., Georgieva, I., Gong, Z., Nanjappan, V., & Georgiev, G. (2021) · Brain Sciences · doi:10.3390/brainsci11020221 · Cited by 184
Hramov, A. E., Maksimenko, V. A., & Pisarchik, A. N. (2021) · Physics Reports · doi:10.1016/j.physrep.2021.03.002 · Cited by 213
EEG Control of a Virtual Helicopter in 3-Dimensional Space Using Intelligent Control Strategies
Royer, A. S., Doud, A. J., Rose, M. L., & He, B. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2077654 · Cited by 216
Li, Y., Zhang, H., Yang, R., Laffitte, Y., Schmill, U., Hu, W., Kaddoura, M., Blondeel, E. J. M., & Cui, B. (2019) · Microsystems & Nanoengineering · doi:10.1038/s41378-019-0077-y · Cited by 210
Brain-computer interface technologies: from signal to action
Ortiz-Rosario, A., & Adeli, H. (2013) · Reviews in the Neurosciences · doi:10.1515/revneuro-2013-0032 · Cited by 213
“It was used recently to demonstrate robotic control in tetraplegic patients (Hochberg et al., 2006, 2012).”
MethodNeural recording and stimulation using wireless networks of microimplants
Lee, J., Leung, V., Lee, A.-H., Huang, J., Asbeck, P., Mercier, P. P., Shellhammer, S., Larson, L., Laiwalla, F., & Nurmikko, A. (2021) · Nature Electronics · doi:10.1038/s41928-021-00631-8 · Cited by 195
Lu, Y., Wang, D., Li, T., Zhao, X., Cao, Y., Yang, H., & Duan, Y. Y. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.04.030 · Cited by 208
“The rapid pace of recent advances in implantable miniature electronic devices has revealed great benefits for patients suffering from neural impairment and disorder, such as deafness, Parkinson’s disease, epilepsy, blindness, intractable pain, and paralysis [1–7].”
Ultrasoft microwire neural electrodes improve chronic tissue integration
Du, Z. J., Kolarcik, C. L., Kozai, T. D. Y., Luebben, S. D., Sapp, S. A., Zheng, X. S., Nabity, J. A., & Cui, X. T. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.02.010 · Cited by 209
Conscious Brain-to-Brain Communication in Humans Using Non-Invasive Technologies
Grau, C., Ginhoux, R., Riera, A., Nguyen, T. L., Chauvat, H., Berg, M., Amengual, J. L., Pascual-Leone, A., & Ruffini, G. (2014) · PLoS ONE · doi:10.1371/journal.pone.0105225 · Cited by 211
“Despite these and other significant advances with human subjects [9–10], invasive methods in humans remain severely limited in their practical usefulness.”
BackgroundNeural Interface Technology for Rehabilitation: Exploiting and Promoting Neuroplasticity
Wang, W., Collinger, J. L., Perez, M. A., Tyler-Kabara, E. C., Cohen, L. G., Birbaumer, N., Brose, S. W., Schwartz, A. B., Boninger, M. L., & Weber, D. J. (2010) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/j.pmr.2009.07.003 · Cited by 213
“Many BCI applications were developed based on cortical representations of movement.(19,21,22) Motor system neurophysiology studies have shown that activity of motor cortical neurons is modulated by movement, and”
InfluentialLi, S., Bai, H., Shepherd, R. F., & Zhao, H. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201813402 · Cited by 209
A review on directional information in neural signals for brain-machine interfaces
Waldert, S., Pistohl, T., Braun, C., Ball, T., Aertsen, A., & Mehring, C. (2009) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2009.08.007 · Cited by 207
“While SUA recordings have been successfully used to implement an online direct motor BMI (Serruya et al., 2002; Taylor et al., 2002; Carmena et al., 2003; Hochberg et al., 2006; Velliste et al., 2008), this has yet to be demonstrated for analog population signals.”
Real-time control of a prosthetic hand using human electrocorticography signals: Technical note
Yanagisawa, T., Hirata, M., Saitoh, Y., Goto, T., Kishima, H., Fukuma, R., Yokoi, H., Kamitani, Y., & Yoshimine, T. (2011) · Journal of Neurosurgery · doi:10.3171/2011.1.jns101421 · Cited by 208
Wireless Neural Recording With Single Low-Power Integrated Circuit
Harrison, R. R., Kier, R. J., Chestek, C. A., Gilja, V., Nuyujukian, P., Ryu, S., Greger, B., Solzbacher, F., & Shenoy, K. V. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2023298 · Cited by 209
“, [1]), the need for completely wireless neural recording systems becomes more important.”
BackgroundMachine-learning-based coadaptive calibration for brain-computer interfaces
Vidaurre, C., Sannelli, C., Müller, K.-R., & Blankertz, B. (2011) · Neural Computation · doi:10.1162/neco_a_00089 · Cited by 207
“…Aertsen, and Mehring (2008), Schalk et al. (2008), and Leuthardt, Freudenberg, Bundy, and Roland (2009) for ECoG-based BCIs and to Carmena et al. (2003), Schwartz (2004), Hochberg et al. (2006), Fetz (2007), Rizk et al. (2009), and Waldert et al. (2009) for a summary in spike-based approaches.”
BackgroundDonoghue, J. P., Nurmikko, A., Black, M., & Hochberg, L. R. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.127209 · Cited by 197
“…more recent preliminary observations in one participant with brainstem stroke and one participant with ALS suggest that the findings in spinal cord injury may generalize across a broad population of persons with tetraplegia arising from various causes (Donoghue et al. 2006; Hochberg et al. 2006a).”
BackgroundMethodInfluentialSelf-citationBansal, A. K., Truccolo, W., Vargas-Irwin, C. E., & Donoghue, J. P. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00781.2011 · Cited by 203
“2009), necessitating the frequent updating of decoding filters (Hochberg et al. 2006).”
BackgroundSelf-citationBrain-Computer Interface Operation of Robotic and Prosthetic Devices
McFarland, D. J., & Wolpaw, J. R. (2008) · Computer · doi:10.1109/mc.2008.409 · Cited by 203
Chronic in vivo stability assessment of carbon fiber microelectrode arrays
Patel, P. R., Zhang, H., Robbins, M. T., Nofar, J. B., Marshall, S. P., Kobylarek, M. J., Kozai, T. D. Y., Kotov, N. A., & Chestek, C. A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066002 · Cited by 204
A Mixed-Signal Multichip Neural Recording Interface With Bandwidth Reduction
Gosselin, B., Ayoub, A. E., Roy, J.-F., Sawan, M., Lepore, F., Chaudhuri, A., & Guitton, D. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2013718 · Cited by 202
“high investigation accuracy in neuroscience experiments, and retrieve the control signals in prosthetic applications [1], [2].”
Background
Metadata
- Authors
- Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P.
- Affiliations
- Brigham and Women's Hospital (US)
- Brown University (US)
- Cyberkinetics (United States) (US)
- Shirley Ryan AbilityLab (US)
- University of Chicago (US)
- Corresponding author
- Donoghue, John P.
- Venue
- Nature
- Published
- 2006-07
- Volume
- 442
- Issue
- 7099
- Pages
- 164-171
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2114004602
- Cited by
- 3,295
- References
- 47
- Citations by year
- 2026: 63 · 2025: 131 · 2024: 113 · 2023: 117 · 2022: 119 · 2021: 158 · 2020: 129 · 2019: 150 · 2018: 150 · 2017: 143 · 2016: 186 · 2015: 169 · 2014: 226 · 2013: 231 · 2012: 199
- FWCI
- 93.11
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Keywords
- tetraplegia, spinal cord injury, brain-computer interface, neuronal ensembles, primary motor cortex, intracortical microelectrode arrays, prosthetic hand control, robotic arm control, movement intention decoding, cervical spinal cord injury, upper limb paralysis
- MeSH terms
- Adult, Bionics, Electrodes, Humans, Male, Middle Aged, Movement, Quadriplegia, Robotics, User-Computer Interface, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.