Neuromotor prostheses (NMPs) aim to replace or restore lost motor functions in paralysed humans by routeing movement-related signals from the brain, around damaged parts of the nervous system, to external effectors. To translate preclinical results from intact animals to a clinically useful NMP, movement signals must persist in cortex after spinal cord injury and be engaged by movement intent when sensory inputs and limb movement are long absent. Furthermore, NMPs would require that intention-driven neuronal activity be converted into a control signal that enables useful tasks. Here we show initial results for a tetraplegic human (MN) using a pilot NMP. Neuronal ensemble activity recorded through a 96-microelectrode array implanted in primary motor cortex demonstrated that intended hand motion modulates cortical spiking patterns three years after spinal cord injury. Decoders were created, providing a 'neural cursor' with which MN opened simulated e-mail and operated devices such as a television, even while conversing. Furthermore, MN used neural control to open and close a prosthetic hand, and perform rudimentary actions with a multi-jointed robotic arm. These early results suggest that NMPs based upon intracortical neuronal ensemble spiking activity could provide a valuable new neurotechnology to restore independence for humans with paralysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Subcutaneous invasive electrophysiological signals can be derived through brain interfaces,[270–272] using electrocorticography (ECoG)[273,274] on the cortical surface as well as local field potentials (LFP)[275,276] extracted from electrodes inserted into the cortex.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [276]
In the citing paper
“Currently, all reported BMI experiments with human patients [26, 35, 57, 58, 150] require the subjects tethered percutaneously to a bench-top computer for neural signal acquisition and decoding.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [57]
In the citing paper
“Additionally, it is apparent from previous work that access to sufficiently large patient populations for concrete and statistically significant conclusions may be difficult to obtain (1–5, 8, 11, 29, 39).”
From Noninvasive neuroimaging enhances continuous neural tracking for robotic device control (2019) · cites this paper as [29]
Citations
Cites
Plum, F. (1960) · Archives of Neurology · doi:10.1001/archneur.1960.03840090124020 · Cited by 10,364
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Georgopoulos, A., Kalaska, J., Caminiti, R., & Massey, J. (1982) · The Journal of Neuroscience · doi:10.1523/jneurosci.02-11-01527.1982 · Cited by 2,130
International Standards for Neurological and Functional Classification of Spinal Cord Injury
Maynard, F. M., Bracken, M. B., Creasey, G., Jr, J. F. D., Donovan, W. H., Ducker, T. B., Garber, S. L., Marino, R. J., Stover, S. L., Tator, C. H., et al. (1997) · Spinal Cord · doi:10.1038/sj.sc.3100432 · Cited by 2,048
Advances in Neural Information Processing Systems 18
Murray, I., Mackay, D., Zoubin Ghahramani, A., & Skilling, J. (2006) · Cited by 1,927
Localization of the motor hand area to a knob on the precentral gyrus. A new landmark
Yousry, T. (1997) · Brain · doi:10.1093/brain/120.1.141 · Cited by 1,837
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Ditunno, J. F., Young, W., Donovan, W. H., & Creasey, G. (1994) · Spinal Cord · doi:10.1038/sc.1994.13 · Cited by 1,643
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Cited by
Items 401–500 of 1,022
Neuronal Ensemble Synchrony during Human Focal Seizures
Truccolo, W., Ahmed, O. J., Harrison, M. T., Eskandar, E. N., Cosgrove, G. R., Madsen, J. R., Blum, A. S., Potter, N., Hochberg, L. R., & Cash, S. S. (2014) · Journal of Neuroscience · doi:10.1523/jneurosci.4567-13.2014 · Cited by 126
Self-citationDecoding Movement From Electrocorticographic Activity: A Review
Volkova, K., Lebedev, M. A., Kaplan, A., & Ossadtchi, A. (2019) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2019.00074 · Cited by 110
“MEAsbased BCIs have been implemented in rats (Chapin et al., 1999; Song et al., 2009), non-human primates (Taylor et al., 2002; Carmena et al., 2003; Gilja et al., 2012; Schaffelhofer et al., 2015) and humans (Hochberg et al., 2006; Collinger et al., 2013; Gilja et al., 2015; Brandman et al., 2017).”
MethodPrediction of upper limb muscle activity from motor cortical discharge during reaching
Pohlmeyer, E. A., Solla, S. A., Perreault, E. J., & Miller, L. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/4/003 · Cited by 118
Fluidic Microactuation of Flexible Electrodes for Neural Recording
Vitale, F., Vercosa, D. G., Rodriguez, A. V., Pamulapati, S. S., Seibt, F., Lewis, E., Yan, J. S., Badhiwala, K., Adnan, M., Royer-Carfagni, G., et al. (2018) · Nano Letters · doi:10.1021/acs.nanolett.7b04184 · Cited by 113
Brain Computer Interfaces in Rehabilitation Medicine
Bockbrader, M. A., Francisco, G. E., Lee, R., Olson, J. D., Solinsky, R. J., & Boninger, M. L. (2018) · PM&R · doi:10.1016/j.pmrj.2018.05.028 · Cited by 126
“Motor BCI systems have been used as investigational assistive devices for individuals with chronic paralysis from multiple causes, including cervical spinal cord injury [13,14,17,18,37-41,51,52,55,72,82-85], spinocerebellar degeneration [15,16,85], amyotrophic lateral sclerosis [86,87], and brainstem stroke [88].”
BackgroundMethodInfluentialKübler, A. (2019) · Neuroethics · doi:10.1007/s12152-019-09409-4 · Cited by 135
“Direct intra-cortical measurement of nerve cell activity can be carried out by means of implanted single electrodes [5], or of electrode arrays, often placed at the motor cortex, that reach a few millimeters into cortical tissue [6].”
MethodPropagating Waves in Human Motor Cortex
Takahashi, K., Saleh, M., Penn, R. D., & Hatsopoulos, N. G. (2011) · Frontiers Human Neuroscience · doi:10.3389/fnhum.2011.00040 · Cited by 113
Self-citationJarosiewicz, B., Masse, N. Y., Bacher, D., Cash, S. S., Eskandar, E., Friehs, G., Donoghue, J. P., & Hochberg, L. R. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/046012 · Cited by 104
Self-citationBrumberg (2011) · Frontiers in Neuroscience · doi:10.3389/fnins.2011.00065 · Cited by 114
“…human volunteers suffering from quadriplegia, LIS, or ALS have been chronically implanted with microelectrode recording systems for BMI control of spelling devices (Kennedy et al., 2000, 2004; Hochberg et al., 2006) and artificial speech synthesizers (Guenther et al., 2009; Brumberg et al., 2010).”
InfluentialIntegrated sensors, MEMS, and microsystems: Reflections on a fantastic voyage
Wise, K. D. (2007) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2007.02.013 · Cited by 133
Neuroprosthetics: from sensorimotor to cognitive disorders
Gupta, A., Vardalakis, N., & Wagner, F. B. (2023) · Communications Biology · doi:10.1038/s42003-022-04390-w · Cited by 121
A Novel Anti‐inflammatory Surface for Neural Electrodes
He, W., McConnell, G. C., Schneider, T. M., & Bellamkonda, R. V. (2007) · Advanced Materials · doi:10.1002/adma.200700943 · Cited by 112
Ultra‐Lightweight Resistive Switching Memory Devices Based on Silk Fibroin
Wang, H., Zhu, B., Wang, H., Ma, X., Hao, Y., & Chen, X. (2016) · Small · doi:10.1002/smll.201600893 · Cited by 116
To sort or not to sort: the impact of spike-sorting on neural decoding performance
Todorova, S., Sadtler, P., Batista, A., Chase, S., & Ventura, V. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056005 · Cited by 107
“…spikingbased BCIs have shown impressive performance both in the lab (Serruya et al 2002, Carmena et al 2003, Mulliken et al 2008, Velliste et al 2008, Suminski et al 2010, Gilja 2012) and in early stage clinical trials with human patients (Hochberg et al 2006, Hochberg 2012, Collinger et al 2013).”
BackgroundMultimodal functional imaging of motor imagery using a novel paradigm
Burianová, H., Marstaller, L., Sowman, P. F., Tesan, G., Rich, A. N., Williams, M., Savage, G. R., & Johnson, B. W. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.01.001 · Cited by 123
“Motor imagery plays a critical role in motor skill learning and sports training (Brouziyne and Molinaro, 2005; Murphy, 1994), as well as in prosthesis control (Hochberg et al., 2006) and motor rehabilitation in patients with motor disorders (Dijkerman et al.”
Factor-Analysis Methods for Higher-Performance Neural Prostheses
Santhanam, G., Yu, B. M., Gilja, V., Ryu, S. I., Afshar, A., Sahani, M., & Shenoy, K. V. (2009) · Journal of Neurophysiology · doi:10.1152/jn.00097.2009 · Cited by 116
“2008) and humans (e.g., Kennedy et al. 2000; Leuthardt et al. 2004; Wolpaw and McFarland 2004; Hochberg et al. 2006; Schalk et al. 2008) can learn to move computer cursors and robotic arms to various target locations simply by activating neural populations that participate in natural arm movements.”
BackgroundBrain-machine interfaces: an overview.
Lebedev, M. (2014) · Translational Neuroscience · doi:10.2478/s13380-014-0212-z · Cited by 112
Computational advances towards linking BOLD and behavior
Serences, J. T., & Saproo, S. (2012) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2011.07.013 · Cited by 101
“…application of MVPA and related decoding techniques and holds great promise for clinical applications such as restoring sight and creating effective neural prostheses for people with limited mobility (see: Andersen, Hwang, & Mulliken, 2010; Haynes, 2009; Hochberg et al., 2006; Weil & Rees, 2010).”
MethodNaïve coadaptive cortical control
Gage, G. J., Ludwig, K. A., Otto, K. J., Ionides, E. L., & Kipke, D. R. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/2/006 · Cited by 109
Skousen, J. L., Merriam, S. M. E., Srivannavit, O., Perlin, G., Wise, K. D., & Tresco, P. A. (2011) · Progress in Brain Research · doi:10.1016/b978-0-444-53815-4.00009-1 · Cited by 111
“Numerous studies have shown that using implanted microelectrode arrays, consciously modulated neural signals can be recorded in both animal subjects as well as human patients for periods of time ranging from months to multiple years, and that these recorded signals can be used to control a number of external devices (…”
BackgroundContinuous neuronal ensemble control of simulated arm reaching by a human with tetraplegia
Chadwick, E. K., Blana, D., Simeral, J. D., Lambrecht, J., Kim, S. P., Cornwell, A. S., Taylor, D. M., Hochberg, L. R., Donoghue, J. P., & Kirsch, R. F. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/034003 · Cited by 109
“Recent work in pilot clinical trials involving four people with tetraplegia [19, 20] has also demonstrated the ability to record and decode information related to movement intent from the human motor cortex.”
BackgroundMethodSelf-citationBridging the divide between neuroprosthetic design, tissue engineering and neurobiology
Leach, J. (2010) · Frontiers in Neuroengineering · doi:10.3389/neuro.16.018.2009 · Cited by 112
“…et al. (2006), chronic recordings in rats with electrodes coated with poly(3,4-ethylenedioxythiophene) (PEDOT; a conducting polymer) (Groenendaal et al., 2000) showed lower impedance FIGURE 1 | The BrainGate® neural interface system created by Cyberkinetics Corp described by Hochberg et al. (2006).”
InfluentialSingle trial discrimination of individual finger movements on one hand: A combined MEG and EEG study
Quandt, F., Reichert, C., Hinrichs, H., Heinze, H. –., Knight, R. T., & Rieger, J. W. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.053 · Cited by 119
“For coarser movements, recent studies succeeded in decoding the kinematics and the position of hand trajectories and arm movements from single-unit recordings in monkeys (Carmena et al., 2003; Taylor et al., 2002) and in humans (Hochberg et al., 2006).”
Pino, G. D., Guglielmelli, E., & Rossini, P. M. (2009) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.03.001 · Cited by 120
“During a 9 months follow-up the patient was able to control a simple one degree of freedom hand prosthesis and to control a PC cursor (Donoghue et al., 2007; Hochberg et al., 2006).”
Optimizing the Decoding of Movement Goals from Local Field Potentials in Macaque Cortex
Markowitz, D. A., Wong, Y. T., Gray, C. M., & Pesaran, B. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.4165-11.2011 · Cited by 110
“Presently, the bestperforming BMIs are based on neuronal spike recordings (Hochberg et al., 2006; Santhanam et al., 2006; Velliste et al., 2008; Aggarwal et al., 2009; Ganguly et al., 2011; Simeral et al., 2011), however, local field potentials (LFPs) offer promise as a robust, reliable alternative…”
BackgroundA cognitive neuroprosthetic that uses cortical stimulation for somatosensory feedback
Klaes, C., Shi, Y., Kellis, S., Minxha, J., Revechkis, B., & Andersen, R. A. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056024 · Cited by 110
The Potential for a Speech Brain–Computer Interface Using Chronic Electrocorticography
Rabbani, Q., Milsap, G., & Crone, N. E. (2019) · Neurotherapeutics · doi:10.1007/s13311-018-00692-2 · Cited by 124
Huo, X., & Ghovanloo, M. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026008 · Cited by 113
“They have been studied mainly in nonhuman primates and more recently on humans [15].”
BackgroundNanomembranes and Nanofibers from Biodegradable Conducting Polymers
Llorens, E., Armelin, E. A., Pérez‐Madrigal, M. M., del Valle, L. J., Alemán, C., & Puiggalí, J. (2013) · Polymers · doi:10.3390/polym5031115 · Cited by 121
“Development of advanced neural interfaces may provide effective treatments for neurological conditions [118,119].”
BackgroundThe sinusoidal probe: a new approach to improve electrode longevity
Sohal, H. S., Jackson, A., Jackson, R., Clowry, G. J., Vassilevski, K., O’Neill, A., & Baker, S. N. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00010 · Cited by 106
Minnikanti, S., Diao, G., Pancrazio, J. J., Xie, X., Rieth, L. W., Solzbacher, F., & Peixoto, N. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.10.031 · Cited by 114
“Prior work has demonstrated that arrays of microelectrodes implanted in the motor cortex yield single unit and local field potential recordings that encode information on intended movement [4].”
BackgroundInvasive or Noninvasive: Understanding Brain-Machine Interface Technology [Conversations in BME
del R. Milan, J., & Carmena, J. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2009.935475 · Cited by 100
A Note on Brain Actuated Spelling with the Berlin Brain-Computer Interface
Blankertz, B., Krauledat, M., Dornhege, G., Williamson, J., Murray-Smith, R., & Müller, K.-R. (2007) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-73281-5_83 · Cited by 106
“It has been shown that invasive BCI systems enable monkeys, and recently also humans, to operate a robotic arm ([3,4]).”
BackgroundHuman motor decoding from neural signals: a review
Tam, W.-K., Wu, T., Zhao, Q., Keefer, E. W., & Yang, Z. (2019) · BMC Biomedical Engineering · doi:10.1186/s42490-019-0022-z · Cited by 119
Dynamic causal modeling with neural fields
Pinotsis, D. A., Moran, R. J., & Friston, K. J. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.08.020 · Cited by 104
“These arrays yield important information about pairwise and higher order correlations, and have been used to study neural activity in visual (Kelly et al., 2007) and motor cortex (Hochberg et al., 2006).”
Alternative communication systems for people with severe motor disabilities: a survey
Pinheiro, C. G., Naves, E. L. M., Pino, P., Losson, E., Andrade, A. D. O., & Bourhis, G. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-31 · Cited by 123
“Experiments comparing times of positioning one cursor on the screen of a computer starting from a joystick and starting from the EEG signals coming from the sensorimotor cortex show the advantage in term of speed and accuracy of the use of the joystick [74].”
MethodAsynchronous Decoding of Dexterous Finger Movements Using M1 Neurons
Aggarwal, V., Acharya, S., Tenore, F., Shin, H.-C., Etienne-Cummings, R., Schieber, M. H., & Thakor, N. V. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.916289 · Cited by 99
“Recently, a report presented a tetraplegic human who was able to control a computer cursor to open e-mail, operate a television, and open and close a prosthetic hand using neuronal ensemble activity from a microelectrode array [5].”
BackgroundNeural ensemble dynamics in dorsal motor cortex during speech in people with paralysis
Stavisky, S. D., Willett, F. R., Wilson, G. H., Murphy, B. A., Rezaii, P., Avansino, D. T., Memberg, W. D., Miller, J. P., Kirsch, R. F., Hochberg, L. R., et al. (2019) · eLife · doi:10.7554/elife.46015 · Cited by 105
Self-citationInterfaces with the Peripheral Nerve for the Control of Neuroprostheses
del Valle, J., & Navarro, X. (2013) · International Review of Neurobiology · doi:10.1016/b978-0-12-420045-6.00002-x · Cited by 105
Human cortical prostheses: lost in translation?
Ryu, S. I., & Shenoy, K. V. (2009) · Neurosurgical Focus · doi:10.3171/2009.4.focus0987 · Cited by 104
Moran, D. (2010) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2010.09.010 · Cited by 103
Nakanishi, Y., Yanagisawa, T., Shin, D., Fukuma, R., Chen, C., Kambara, H., Yoshimura, N., Hirata, M., Yoshimine, T., & Koike, Y. (2013) · PLoS ONE · doi:10.1371/journal.pone.0072085 · Cited by 103
“These techniques have also been applied in humans to control a cursor [24] and a virtual keyboard and virtual hand [25].”
MethodPain-related changes in the brain: diagnostic and therapeutic potentials
Saab, C. Y. (2012) · Trends in Neurosciences · doi:10.1016/j.tins.2012.06.002 · Cited by 114
Weber, D. J., London, B. M., Hokanson, J. A., Ayers, C. A., Gaunt, R. A., Torres, R. R., Zaaimi, B., & Miller, L. E. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2163145 · Cited by 100
“The importance of somatosensory feedback prompts the need for an afferent interface to parallel the efferent interfaces that have been under development for over a decade [3–8].”
BackgroundBrain–computer interfacing based on cognitive control
Vansteensel, M. J., Hermes, D., Aarnoutse, E. J., Bleichner, M. G., Schalk, G., van Rijen, P. C., Leijten, F. S. S., & Ramsey, N. F. (2010) · Annals of Neurology · doi:10.1002/ana.21985 · Cited by 102
“Results from EEG and intracortical studies have been promising, showing that severely paralyzed patients are able to guide a cursor over a computer screen by imagining movement.(11,12) Brain regions subserving nonmotor functions are new emerging targets for a number of reasons.”
BackgroundPerge, J. A., Zhang, S., Malik, W. Q., Homer, M. L., Cash, S., Friehs, G., Eskandar, E. N., Donoghue, J. P., & Hochberg, L. R. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/4/046007 · Cited by 100
Self-citationReview: Human Intracortical Recording and Neural Decoding for Brain–Computer Interfaces
Brandman, D. M., Cash, S. S., & Hochberg, L. R. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2677443 · Cited by 103
“One approach to addressing noise may be smoothing inputs [11], [111] or by using a Weiner filter.”
BackgroundMethodInfluentialSelf-citationDecoding spoken English from intracortical electrode arrays in dorsal precentral gyrus
Wilson, G. H., Stavisky, S. D., Willett, F. R., Avansino, D. T., Kelemen, J. N., Hochberg, L. R., Henderson, J. M., Druckmann, S., & Shenoy, K. V. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abbfef · Cited by 103
Self-citationRodriguez-Perez, A., Ruiz-Amaya, J., Delgado-Restituto, M., & Rodriguez-Vazquez, Á. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2187352 · Cited by 103
Design and analysis of closed-loop decoder adaptation algorithms for brain-machine interfaces
Dangi, S., Orsborn, A. L., Moorman, H. G., & Carmena, J. M. (2013) · Neural Computation · doi:10.1162/neco_a_00460 · Cited by 103
“, 2008; Moritz, Perlmutter, & Fetz, 2008; Velliste, Perel, Spalding, Whitford, & Schwartz, 2008; Ganguly & Carmena, 2009; O’Doherty, Lebedev, Hanson, Fitzsimmons, & Nicolelis, 2009; Suminski, Tkach, Fagg, & Hatsopoulos, 2010; Ethier, Oby, Bauman, & Miller, 2012), and humans (Hochberg et al., 2006; Kim, Simeral, Hochbe…”
BackgroundChristie, B. P., Tat, D. M., Irwin, Z. T., Gilja, V., Nuyujukian, P., Foster, J. D., Ryu, S. I., Shenoy, K. V., Thompson, D. E., & Chestek, C. A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016009 · Cited by 103
Latent Factors and Dynamics in Motor Cortex and Their Application to Brain–Machine Interfaces
Pandarinath, C., Ames, K. C., Russo, A. A., Farshchian, A., Miller, L. E., Dyer, E. L., & Kao, J. C. (2018) · The Journal of Neuroscience · doi:10.1523/jneurosci.1669-18.2018 · Cited by 103
“…decoding movement intent from neuron spiking activity to con-trol external devices or restore movement (Taylor et al., 2002; Carmena et al., 2003; Hochberg et al., 2006, 2012; Ethier et al., 2012; Collinger et al., 2013; Sadtler et al., 2014; Gilja et al., 2015; Ajiboye et al., 2017; Pandarinath…”
MethodApplications of brain-computer interfaces to the control of robotic and prosthetic arms
Vilela, M., & Hochberg, L. R. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63934-9.00008-1 · Cited by 118
Self-citationNeuromodulation, Agency and Autonomy
Glannon, W. (2013) · Brain Topography · doi:10.1007/s10548-012-0269-3 · Cited by 123
“Brain–Computer Interfaces for Tetraplegia and Locked-In Syndrome Brain–computer interfaces are used mainly for patients with tetraplegia resulting from brain and spinal cord injuries (Hochberg et al. 2006, 2012; Leuthardt et al. 2006; Kennedy et al. 2011 ).”
Efficient Decoding With Steady-State Kalman Filter in Neural Interface Systems
Malik, W. Q., Truccolo, W., Brown, E. N., & Hochberg, L. R. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2092443 · Cited by 101
“At the beginning of the BrainGate 1 NIS pilot clinical trial, a linear decoder was used to predict cursor position from neural activity measured from a neuronal ensemble [6].”
MethodSelf-citationLind, G., Linsmeier, C. E., Thelin, J., & Schouenborg, J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/4/046005 · Cited by 98
Micera, S., Citi, L., Rigosa, J., Carpaneto, J., Raspopovic, S., Di Pino, G., Rossini, L., Yoshida, K., Denaro, L., Dario, P., et al. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2038726 · Cited by 101
Designing for uncertain, asymmetric control: Interaction design for brain–computer interfaces
Williamson, J. H., Murray‐Smith, R., Blankertz, B., Krauledat, M., & Müller, K. R. (2009) · International Journal of Human-Computer Studies · doi:10.1016/j.ijhcs.2009.05.009 · Cited by 106
“It has been shown that invasive BCI systems enable monkeys, and recently also humans, to operate a robotic arm (Hochberg et al. (2006); Carmena et al. (2003)).”
BackgroundLu, Y., Wang, T., Cai, Z., Cao, Y., Yang, H., & Duan, Y. Y. (2008) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2008.11.036 · Cited by 107
Mechanically adaptive nanocomposites for neural interfacing
Capadona, J. R., Tyler, D. J., Zorman, C. A., Rowan, S. J., & Weder, C. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.97 · Cited by 101
Movement is governed by rotational neural dynamics in spinal motor networks
Lindén, H., Petersen, P. C., Vestergaard, M., & Berg, R. W. (2022) · Nature · doi:10.1038/s41586-022-05293-w · Cited by 117
Brain–computer interfaces (BCIs): Detection instead of classification
Schalk, G., Brunner, P., Gerhardt, L. A., Bischof, H., & Wolpaw, J. R. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.08.010 · Cited by 108
“…the brain could provide new augmentative techology that does not require muscle control (e.g., Birbaumer et l., 1999; Farwell and Donchin, 1988; Hochberg et al., 2006; ennedy et al., 2000; Kübler et al., 1999, 2005; McFarland et l., 1993; Müller and Blankertz, 2006; Pfurtscheller et al.,…”
BackgroundMethodInfluentialFreire, M. A. M., Morya, E., Faber, J., Santos, J. R., Guimaraes, J. S., Lemos, N. A. M., Sameshima, K., Pereira, A., Ribeiro, S., & Nicolelis, M. A. L. (2011) · PLoS ONE · doi:10.1371/journal.pone.0027554 · Cited by 97
Decoding three-dimensional reaching movements using electrocorticographic signals in humans
Bundy, D. T., Pahwa, M., Szrama, N., & Leuthardt, E. C. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026021 · Cited by 96
“…have been used to control closed-loop BCI systems in non-human primates (Wessberg et al 2000, Serruya et al 2002, Taylor et al 2002, Carmena et al 2003, Velliste et al 2008) and human patients (Kennedy and Bakay 1998, Hochberg et al 2006, Kim et al 2008, Collinger et al 2013, Wodlinger et al 2015).”
MethodBiederman, W., Yeager, D. J., Narevsky, N., Leverett, J., Neely, R., Carmena, J. M., Alon, E., & Rabaey, J. M. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2384736 · Cited by 96
“, [1]–[3]), patients with implanted micro-electrode arrays successfully controlled robotic prostheses to perform motor tasks.”
BackgroundNeuroenhancement: status quo and perspectives
Normann, C., & Berger, T. (2008) · European Archives of Psychiatry and Clinical Neuroscience · doi:10.1007/s00406-008-5022-2 · Cited by 107
“The deaf learn to hear by cochlear implants, brain–machine interfaces control artificial extremities just by the power of the will [11].”
BackgroundHauschild, M., Mulliken, G. H., Fineman, I., Loeb, G. E., & Andersen, R. A. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1215092109 · Cited by 96
Nanotechnology and Nanomaterials for Improving Neural Interfaces
Wang, M., Mi, G., Shi, D., Bassous, N. J., Hickey, D. J., & Webster, T. J. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201700905 · Cited by 106
Should patients with brain implants undergo MRI?
Erhardt, J. B., Fuhrer, E., Gruschke, O. G., Leupold, J., Wapler, M. C., Hennig, J., Stieglitz, T., & Korvink, J. G. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab4e4 · Cited by 105
A real-time classification algorithm for EEG-based BCI driven by self-induced emotions
Iacoviello, D., Petracca, A., Spezialetti, M., & Placidi, G. (2015) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.08.011 · Cited by 92
Ownership of an artificial limb induced by electrical brain stimulation
Collins, K. L., Guterstam, A., Cronin, J., Olson, J. D., Ehrsson, H. H., & Ojemann, J. G. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1616305114 · Cited by 96
“Our findings provide a conceptually important step toward achieving a robotic prosthesis that not only moves and provides sensory feedback via electrodes implanted in the brain (7, 42, 43) but also feels just like one’s own limb.”
BackgroundRavikumar, M., Sunil, S., Black, J., Barkauskas, D. S., Haung, A. Y., Miller, R. H., Selkirk, S. M., & Capadona, J. R. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.05.084 · Cited by 95
Global cortical activity predicts shape of hand during grasping
Agashe, H. A., Paek, A. Y., Zhang, Y., & Contreras-Vidal, J. L. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00121 · Cited by 103
“BMI which extract movement intent from brain activity and control external devices are another possible strategy to regain hand function (Birbaumer, 2006; Lebedev andNicolelis, 2006) while also tracking plasticity in the brain.”
BackgroundInfluentialNeural stimulation and recording performance in human sensorimotor cortex over 1500 days
Hughes, C. L., Flesher, S. N., Weiss, J. M., Downey, J. E., Boninger, M., Collinger, J. L., & Gaunt, R. A. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac18ad · Cited by 96
Davis, T. S., Parker, R. A., House, P. A., Bagley, E., Wendelken, S., Normann, R. A., & Greger, B. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/065003 · Cited by 91
Shanechi, M. M., Hu, R. C., Powers, M., Wornell, G. W., Brown, E. N., & Williams, Z. M. (2012) · Nature Neuroscience · doi:10.1038/nn.3250 · Cited by 96
A system for neural recording and closed-loop intracortical microstimulation in awake rodents.
Venkatraman, S., Elkabany, K., Long, J. D., Yao, Y., & Carmena, J. M. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005944 · Cited by 96
Grasp Movement Decoding from Premotor and Parietal Cortex
Townsend, B. R., Subasi, E., & Scherberger, H. (2011) · Journal of Neuroscience · doi:10.1523/jneurosci.2451-11.2011 · Cited by 102
“…decoding of 2D and 3D hand kinematics, mainly from M1 activity, to control robotic arm and hand movements (Serruya et al., 2002; Taylor et al., 2002; Carmena et al., 2003; Wolpaw and McFarland, 2004; Hochberg et al., 2006; Velliste et al., 2008; Aggarwal et al., 2009; VargasIrwin et al., 2010).”
MethodIntracortical Recording Interfaces: Current Challenges to Chronic Recording Function
Gunasekera, B., Saxena, T., Bellamkonda, R., & Karumbaiah, L. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn5002864 · Cited by 93
Performance measurement for brain–computer or brain–machine interfaces: a tutorial
Thompson, D. E., Quitadamo, L. R., Mainardi, L., Laghari, K. U. R., Gao, S., Kindermans, P.-J., Simeral, J. D., Fazel-Rezai, R., Matteucci, M., Falk, T. H., et al. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/035001 · Cited by 87
Surface-modified microelectrode array with flake nanostructure for neural recording and stimulation
Kim, J.-H., Kang, G., Nam, Y., & Choi, Y.-K. (2010) · Nanotechnology · doi:10.1088/0957-4484/21/8/085303 · Cited by 90
Hamamé, C. M., Vidal, J. R., Ossandón, T., Jerbi, K., Dalal, S. S., Minotti, L., Bertrand, O., Kahane, P., & Lachaux, J.-P. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.07.087 · Cited by 105
“Moreover, there is also a body of evidence for a distributed fronto-temporal network sustaining mental imagery (Ishai et al., 2000; Zimmer, 2008) and thus revealing further functional and anatomical overlap.”
BackgroundElectronic and Ionic Materials for Neurointerfaces
Ferro, M. D., & Melosh, N. A. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201704335 · Cited by 96
Ando, H., Takizawa, K., Yoshida, T., Matsushita, K., Hirata, M., & Suzuki, T. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2514522 · Cited by 95
Stimulus-artifact elimination in a multi-electrode system.
Brown, E. A., Ross, J. D., Blum, R. A., Nam, Y., Wheeler, B. C., & DeWeerth, S. P. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.918285 · Cited by 95
“Such is the case for some of the ambitious brain–computer interfacing efforts for prosthetic applications [4], [5], in vivo applications [6]–[8], and in vitro applications such as our Micro Neural Interfacing System ( NIS) effort in the development of 3-D in vitro neural models [9]–[11].”
BackgroundA fully implantable 96-channel neural data acquisition system
Rizk, M., Bossetti, C. A., Jochum, T. A., Callender, S. H., Nicolelis, M. A. L., Turner, D. A., & Wolf, P. D. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/2/026002 · Cited by 89
Willsey, M. S., Shah, N. P., Avansino, D. T., Hahn, N. V., Jamiolkowski, R. M., Kamdar, F. B., Hochberg, L. R., Willett, F. R., & Henderson, J. M. (2025) · Nature Medicine · doi:10.1038/s41591-024-03341-8 · Cited by 120
“In motor BCIs, most effort has focused on controlling single effectors such as computer cursors for point-and-click cursor control and robotic arms for reaching and grasping (where fingers moved as a group) 8–16 .”
Self-citationDetection of motor execution using a hybrid fNIRS-biosignal BCI: a feasibility study
Zimmermann, R., Marchal-Crespo, L., Edelmann, J., Lambercy, O., Fluet, M.-C., Riener, R., Wolf, M., & Gassert, R. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-4 · Cited by 93
“Microelectrode-arrays were implanted in the cortex or electrocorticography (ECoG) was used to record brain activity, resulting in BCIs to control cursors or, more recently, prostheses [5-8].”
MethodA hybrid BMI-based exoskeleton for paresis: EMG control for assisting arm movements
Kawase, T., Sakurada, T., Koike, Y., & Kansaku, K. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa525f · Cited by 105
On the Necessity of Ethical Guidelines for Novel Neurotechnologies
Goering, S., & Yuste, R. (2016) · Cell · doi:10.1016/j.cell.2016.10.029 · Cited by 94
“Such interfaces have provided the ability for paralyzed patients to move prosthetic limbs (Hochberg et al., 2006).”
BackgroundNeural decoding using gyral and intrasulcal electrocorticograms
Yanagisawa, T., Hirata, M., Saitoh, Y., Kato, A., Shibuya, D., Kamitani, Y., & Yoshimine, T. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.069 · Cited by 102
“, 2008; Wolpaw and McFarland, 2004), neuronal ensemble activity recorded intracortically (Donoghue, 2002; Georgopoulos et al., 1986; Hochberg et al., 2006; Serruya et al., 2002; Truccolo et al., 2008; Wessberg et al., 2000), local field potentials (Andersen et al.”
BackgroundMapping brain activity with flexible graphene micro-transistors
Blaschke, B. M., Tort-Colet, N., Guimerà-Brunet, A., Weinert, J., Rousseau, L., Heimann, A., Drieschner, S., Kempski, O., Villa, R., Sanchez-Vives, M. V., et al. (2017) · 2D Materials · doi:10.1088/2053-1583/aa5eff · Cited by 90
Engineering Artificial Somatosensation Through Cortical Stimulation in Humans
Lee, B., Kramer, D., Armenta Salas, M., Kellis, S., Brown, D., Dobreva, T., Klaes, C., Heck, C., Liu, C., & Andersen, R. A. (2018) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2018.00024 · Cited by 91
“To restore function to such individuals, brain-machine interfaces (BMIs) are being designed to extract motor execution signals from cortex and decode them to operate physical or virtual effectors (Andersen et al., 2004a,b, 2010; Hochberg et al., 2006; Andersen and Cui, 2009; Kim et al., 2011; O’Doherty et al., 2011; S…”
BackgroundShi, Z., Zheng, F., Zhou, Z., Li, M., Fan, Z., Ye, H., Zhang, S., Xiao, T., Chen, L., Tao, T. H., et al. (2019) · Advanced Science · doi:10.1002/advs.201801617 · Cited by 94
From thought to action: The brain–machine interface in posterior parietal cortex
Andersen, R. A., Aflalo, T., & Kellis, S. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1902276116 · Cited by 94
Single unit action potentials in humans and the effect of seizure activity
Merricks, E. M., Smith, E. H., McKhann, G. M., Goodman, R. R., Bateman, L. M., Emerson, R. G., Schevon, C. A., & Trevelyan, A. J. (2015) · Brain · doi:10.1093/brain/awv208 · Cited by 104
Rewiring neural interactions by micro-stimulation
Rebesco, J. M. (2010) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2010.00039 · Cited by 93
Active Microelectronic Neurosensor Arrays for Implantable Brain Communication Interfaces
Song, Y.-K., Borton, D. A., Park, S., Patterson, W. R., Bull, C. W., Laiwalla, F., Mislow, J., Simeral, J. D., Donoghue, J. P., & Nurmikko, A. V. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2024310 · Cited by 95
“A contemporary version of such a brain recording platform, cabling the cortical neuroprobe from a subject’s head to the signal acquisition and processing electronics, has been used in the first human pilot trials involving chronic implants in severely paralyzed patients [ 9 ].”
Self-citationPasqualotto, E., Matuz, T., Federici, S., Ruf, C. A., Bartl, M., Belardinelli, M. O., Birbaumer, N., & Halder, S. (2015) · Neurorehabilitation and neural repair · doi:10.1177/1545968315575611 · Cited by 105
Population decoding of motor cortical activity using a generalized linear model with hidden states
Lawhern, V., Wu, W., Hatsopoulos, N., & Paninski, L. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.03.024 · Cited by 91
“The primary goal of this BMI research is to be able to restore motor function to physically disabled patients (Hochberg et al., 2006): spike recordings would be " decoded " to provide an external prosthetic device with a neurally-controlled signal in the hope that the movement can be restored in…”
Metadata
- Authors
- Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P.
- Affiliations
- Brigham and Women's Hospital (US)
- Brown University (US)
- Cyberkinetics (United States) (US)
- Shirley Ryan AbilityLab (US)
- University of Chicago (US)
- Corresponding author
- Donoghue, John P.
- Venue
- Nature
- Published
- 2006-07
- Volume
- 442
- Issue
- 7099
- Pages
- 164-171
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2114004602
- Cited by
- 3,295
- References
- 47
- Citations by year
- 2026: 63 · 2025: 131 · 2024: 113 · 2023: 117 · 2022: 119 · 2021: 158 · 2020: 129 · 2019: 150 · 2018: 150 · 2017: 143 · 2016: 186 · 2015: 169 · 2014: 226 · 2013: 231 · 2012: 199
- FWCI
- 93.11
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Keywords
- tetraplegia, spinal cord injury, brain-computer interface, neuronal ensembles, primary motor cortex, intracortical microelectrode arrays, prosthetic hand control, robotic arm control, movement intention decoding, cervical spinal cord injury, upper limb paralysis
- MeSH terms
- Adult, Bionics, Electrodes, Humans, Male, Middle Aged, Movement, Quadriplegia, Robotics, User-Computer Interface, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.