Neuronal ensemble control of prosthetic devices by a human with tetraplegia
The DOI matches its Crossref record; 46 of the 47 references it cites were found in a registry or an index.
Abstract
Neuromotor prostheses (NMPs) aim to replace or restore lost motor functions in paralysed humans by routeing movement-related signals from the brain, around damaged parts of the nervous system, to external effectors. To translate preclinical results from intact animals to a clinically useful NMP, movement signals must persist in cortex after spinal cord injury and be engaged by movement intent when sensory inputs and limb movement are long absent. Furthermore, NMPs would require that intention-driven neuronal activity be converted into a control signal that enables useful tasks. Here we show initial results for a tetraplegic human (MN) using a pilot NMP. Neuronal ensemble activity recorded through a 96-microelectrode array implanted in primary motor cortex demonstrated that intended hand motion modulates cortical spiking patterns three years after spinal cord injury. Decoders were created, providing a 'neural cursor' with which MN opened simulated e-mail and operated devices such as a television, even while conversing. Furthermore, MN used neural control to open and close a prosthetic hand, and perform rudimentary actions with a multi-jointed robotic arm. These early results suggest that NMPs based upon intracortical neuronal ensemble spiking activity could provide a valuable new neurotechnology to restore independence for humans with paralysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Subcutaneous invasive electrophysiological signals can be derived through brain interfaces,[270–272] using electrocorticography (ECoG)[273,274] on the cortical surface as well as local field potentials (LFP)[275,276] extracted from electrodes inserted into the cortex.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [276]
In the citing paper
“Currently, all reported BMI experiments with human patients [26, 35, 57, 58, 150] require the subjects tethered percutaneously to a bench-top computer for neural signal acquisition and decoding.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [57]
In the citing paper
“Additionally, it is apparent from previous work that access to sufficiently large patient populations for concrete and statistically significant conclusions may be difficult to obtain (1–5, 8, 11, 29, 39).”
From Noninvasive neuroimaging enhances continuous neural tracking for robotic device control (2019) · cites this paper as [29]
Citations
Cites
Plum, F. (1960) · Archives of Neurology · doi:10.1001/archneur.1960.03840090124020 · Cited by 10,364
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Georgopoulos, A., Kalaska, J., Caminiti, R., & Massey, J. (1982) · The Journal of Neuroscience · doi:10.1523/jneurosci.02-11-01527.1982 · Cited by 2,130
International Standards for Neurological and Functional Classification of Spinal Cord Injury
Maynard, F. M., Bracken, M. B., Creasey, G., Jr, J. F. D., Donovan, W. H., Ducker, T. B., Garber, S. L., Marino, R. J., Stover, S. L., Tator, C. H., et al. (1997) · Spinal Cord · doi:10.1038/sj.sc.3100432 · Cited by 2,048
Advances in Neural Information Processing Systems 18
Murray, I., Mackay, D., Zoubin Ghahramani, A., & Skilling, J. (2006) · Cited by 1,927
Localization of the motor hand area to a knob on the precentral gyrus. A new landmark
Yousry, T. (1997) · Brain · doi:10.1093/brain/120.1.141 · Cited by 1,837
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Ditunno, J. F., Young, W., Donovan, W. H., & Creasey, G. (1994) · Spinal Cord · doi:10.1038/sc.1994.13 · Cited by 1,643
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Cited by
Items 201–300 of 1,022
Brain-computer interfaces: Definitions and principles
(2020) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-63934-9.00002-0 · Cited by 178
Mobile cognition: imaging the human brain in the ‘real world’
Stangl, M., Maoz, S. L., & Suthana, N. (2023) · Nature Reviews Neuroscience · doi:10.1038/s41583-023-00692-y · Cited by 183
Classification of Hand Movements From EEG Using a Deep Attention-Based LSTM Network
Zhang, G., Davoodnia, V., Sepas-Moghaddam, A., Zhang, Y., & Etemad, A. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2956998 · Cited by 201
“In particular, in order to perform everyday tasks, the control of hand movements is of critical importance for patients [6].”
BackgroundEmulation of computer mouse control with a noninvasive brain–computer interface
McFarland, D. J., Krusienski, D. J., Sarnacki, W. A., & Wolpaw, J. R. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/2/001 · Cited by 202
WIMAGINE: Wireless 64-Channel ECoG Recording Implant for Long Term Clinical Applications
Mestais, C. S., Charvet, G., Sauter-Starace, F., Foerster, M., Ratel, D., & Benabid, A. L. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2333541 · Cited by 202
Activity-dependent neural plasticity from bench to bedside
Ganguly, K., & Poo, M.-M. (2013) · Neuron · doi:10.1016/j.neuron.2013.10.028 · Cited by 202
A brain-computer interface with vibrotactile biofeedback for haptic information
Chatterjee, A., Aggarwal, V., Ramos, A., Acharya, S., & Thakor, N. V. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-40 · Cited by 194
Decoding spectrotemporal features of overt and covert speech from the human cortex
Martin, S., Brunner, P., Holdgraf, C., Heinze, H.-J., Crone, N. E., Rieger, J., Schalk, G., Knight, R. T., & Pasley, B. N. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00014 · Cited by 200
Accurate decoding of reaching movements from field potentials in the absence of spikes
Flint, R. D., Lindberg, E. W., Jordan, L. R., Miller, L. E., & Slutzky, M. W. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/4/046006 · Cited by 201
“Movement-related information derived from spikes in the motor cortex (M1) has been used to control brain–machine interfaces (BMIs) that allow users to move a computer cursor [1–4] or a robotic arm [5], or to reanimate paralyzed muscles via functional electrical stimulation (FES [6–8]).”
MethodZhang, J., Laiwalla, F., Kim, J. A., Urabe, H., Van Wagenen, R., Song, Y.-K., Connors, B. W., Zhang, F., Deisseroth, K., & Nurmikko, A. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/055007 · Cited by 193
“Since the standard ‘non-optical’ MEAs used as the basis for our devices are extensively employed in in vivo extracellular recording, especially in primates [46], we suggest that our optrode–MEA constructs may also be applicable to in vivo brain structures such as the motor-cortex [1, 27], where selective activation or…”
BackgroundHeterogeneous neuronal firing patterns during interictal epileptiform discharges in the human cortex
Keller, C. J., Truccolo, W., Gale, J. T., Eskandar, E., Thesen, T., Carlson, C., Devinsky, O., Kuzniecky, R., Doyle, W. K., Madsen, J. R., et al. (2010) · Brain · doi:10.1093/brain/awq112 · Cited by 194
Self-citationParylene-based flexible neural probes with PEDOT coated surface for brain stimulation and recording
Castagnola, V., Descamps, E., Lecestre, A., Dahan, L., Remaud, J., Nowak, L. G., & Bergaud, C. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.09.004 · Cited by 183
A Deep Learning Method for Classification of EEG Data Based on Motor Imagery
An, X., Kuang, D., Guo, X., Zhao, Y., & He, L. (2014) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-09330-7_25 · Cited by 183
“Here the channel C3, C4, Fc4 were chose as the meta data and the combination tactics to boost each weak classifiers refer to follow [15][16]:”
MethodKrucoff, M. O., Rahimpour, S., Slutzky, M. W., Edgerton, V. R., & Turner, D. A. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00584 · Cited by 187
“…to circumvent lesions and restore functionality (Wolpaw and McFarland, 1994; Kennedy and Bakay, 1998; Leuthardt et al., 2004; Monfils et al., 2004; Hochberg et al., 2006, 2012;Moritz et al., 2008; O’Doherty et al., 2009; Ethier et al., 2012; Collinger et al., 2013; Guggenmos et al., 2013; Ifft et…”
BackgroundMethodImplant Size and Fixation Mode Strongly Influence Tissue Reactions in the CNS
Thelin, J., Jörntell, H., Psouni, E., Garwicz, M., Schouenborg, J., Danielsen, N., & Linsmeier, C. E. (2011) · PLoS ONE · doi:10.1371/journal.pone.0016267 · Cited by 191
“Electrodes implanted in humans are expected to function for a very long time, in some cases nearly a whole lifetime and human and primate studies have shown that electrodes can function for several years [12,13].”
BackgroundChandrakumar, H., & Markovic, D. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2753824 · Cited by 187
Kozai, T. D. Y., Gugel, Z., Li, X., Gilgunn, P. J., Khilwani, R., Ozdoganlar, O. B., Fedder, G. K., Weber, D. J., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.07.039 · Cited by 193
Human Intracranial Recordings and Cognitive Neuroscience
Mukamel, R., & Fried, I. (2012) · Annual Review of Psychology · doi:10.1146/annurev-psych-120709-145401 · Cited by 182
“These spiking patterns were successfully decoded to allow 2D control of a computer cursor on the screen (Hochberg et al. 2006).”
BackgroundMethodSpike Sorting: The First Step in Decoding the Brain: The first step in decoding the brain
Gibson, S., Judy, J. W., & Markovic, D. (2012) · IEEE Signal Processing Magazine · doi:10.1109/msp.2011.941880 · Cited by 189
“Similarly, most neural prosthetic technologies employ some sort of “decoding” algorithm—which may decode movement [11], [12], [14], intentions [15], or memories [13]—that typically operates on signals from individual neurons.”
Neuromodulation in the restoration of function after spinal cord injury
James, N. D., McMahon, S. B., Field-Fote, E. C., & Bradbury, E. J. (2018) · The Lancet Neurology · doi:10.1016/s1474-4422(18)30287-4 · Cited by 184
Electrodeposited polypyrrole/carbon nanotubes composite films electrodes for neural interfaces
Lu, Y., Li, T., Zhao, X., Li, M., Cao, Y., Yang, H., & Duan, Y. Y. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.03.022 · Cited by 191
“These devices have shown significant clinical effectiveness and a great potential as an alternative treatment in patients suffering from neural impairment and disorders, such as deafness, Parkinson’s disease, intractable pain, paralysis and epilepsy [2,3].”
BackgroundHermesE: A 96-Channel Full Data Rate Direct Neural Interface in 0.13 $\mu$m CMOS
Gao, H., Walker, R. M., Nuyujukian, P., Makinwa, K. A. A., Shenoy, K. V., Murmann, B., & Meng, T. H. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2012.2185338 · Cited by 189
Nonlinear Dynamic Modeling of Spike Train Transformations for Hippocampal-Cortical Prostheses
Song, D., Chan, R. H. M., Marmarelis, V. Z., Hampson, R. E., Deadwyler, S. A., & Berger, T. W. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.891948 · Cited by 187
Hybrid EEG-fNIRS Asynchronous Brain-Computer Interface for Multiple Motor Tasks
Buccino, A. P., Keles, H. O., & Omurtag, A. (2016) · PLOS ONE · doi:10.1371/journal.pone.0146610 · Cited by 183
A recurrent neural network for closed-loop intracortical brain–machine interface decoders
Sussillo, D., Nuyujukian, P., Fan, J. M., Kao, J. C., Stavisky, S. D., Ryu, S., & Shenoy, K. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026027 · Cited by 186
“[9, 10], a fundamental limitation of these systems is the”
BackgroundExtracting kinematic parameters for monkey bipedal walking from cortical neuronal ensemble activity
Fitzsimmons, N. A. (2009) · Frontiers in Integrative Neuroscience · doi:10.3389/neuro.07.003.2009 · Cited by 186
An auditory oddball brain–computer interface for binary choices
Halder, S., Rea, M., Andreoni, R., Nijboer, F., Hammer, E. M., Kleih, S. C., Birbaumer, N., & Kübler, A. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.11.087 · Cited by 181
“Alternative BCIs not using EEG but functional magnetic resonance imaging (Sitaram et al., 2007a), implanted sensors (Leuthardt et al., 2004; Hochberg et al., 2006), magnetoencephalography (MEG) (Mellinger et al., 2007) and near infrared red spectroscopy (NIRS) (Sitaram et al., 2007b; Wriessnegger…”
Unscented Kalman Filter for Brain-Machine Interfaces
Li, Z., O'Doherty, J. E., Hanson, T. L., Lebedev, M. A., Henriquez, C. S., & Nicolelis, M. A. L. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006243 · Cited by 186
“The Wiener filter has been used in many studies [3,17,18,19,20,44] and remains a staple of BMI research because of its relative simplicity and efficacy.”
MethodA Brain-Machine Interface Enables Bimanual Arm Movements in Monkeys
Ifft, P. J., Shokur, S., Li, Z., Lebedev, M. A., & Nicolelis, M. A. L. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3006159 · Cited by 173
“Previously, to reach the same goal, single-effector BMI studies have employed a co-adaptive decoding model with iteratively updated tuning properties (25), requested subjects to imagine movements (13, 26), or had them passively observe effector movements (27, 28).”
Single-trial dynamics of motor cortex and their applications to brain-machine interfaces
Kao, J. C., Nuyujukian, P., Ryu, S. I., Churchland, M. M., Cunningham, J. P., & Shenoy, K. V. (2015) · Nature Communications · doi:10.1038/ncomms8759 · Cited by 182
Schultz, A. E., & Kuiken, T. A. (2011) · PM&R · doi:10.1016/j.pmrj.2010.06.016 · Cited by 186
“into the primary motor cortex (C) of a patient with tetraplegia ission from Macmillan Publishers Ltd: Nature, [63], Copyright © nted perm”
BackgroundMethodInfluentialWeiland, J. D., & Humayun, M. S. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2314733 · Cited by 186
Neuroplasticity and brain repair after stroke
Cramer, S. C., & Riley, J. D. (2008) · Current Opinion in Neurology · doi:10.1097/wco.0b013e3282f36cb6 · Cited by 182
Kaya, M., Binli, M. K., Ozbay, E., Yanar, H., & Mishchenko, Y. (2018) · Scientific Data · doi:10.1038/sdata.2018.211 · Cited by 178
Wireless Neurosensor for Full-Spectrum Electrophysiology Recordings during Free Behavior
Yin, M., Borton, D. A., Komar, J., Agha, N., Lu, Y., Li, H., Laurens, J., Lang, Y., Li, Q., Bull, C., et al. (2014) · Neuron · doi:10.1016/j.neuron.2014.11.010 · Cited by 175
“Such tethered studies have produced pioneering results (Collinger et al., 2013; Hochberg et al., 2006, 2012), but technology continues to limit the application to paralyzed individuals.”
BackgroundFlint, R. D., Wright, Z. A., Scheid, M. R., & Slutzky, M. W. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056005 · Cited by 183
A Magneto-Inductive Sensor Based Wireless Tongue-Computer Interface
Huo, X., Wang, J., & Ghovanloo, M. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2003375 · Cited by 182
“For instance, gaze towards objects of interest disrupts eye-based control [10].”
Takmakov, P., Ruda, K., Scott Phillips, K., Isayeva, I. S., Krauthamer, V., & Welle, C. G. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/2/026003 · Cited by 178
Szostak, K. M., Grand, L., & Constandinou, T. G. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00665 · Cited by 168
“…(Adrian and Bronk, 1929; Williams and Parsons-Smith, 1949; Hubel and Wiesel, 1959; Marg and Adams, 1967; Halgren et al., 1978; Georgopoulos et al., 1986; Ojemann et al., 1988; Riehle et al., 1997; Kennedy and Bakay, 1998; Stanley et al., 1999; Nicolelis et al., 2003; Hochberg et al., 2006).”
BackgroundEvent-related beta EEG-changes during passive and attempted foot movements in paraplegic patients
Müller-Putz, G. R., Zimmermann, D., Graimann, B., Nestinger, K., Korisek, G., & Pfurtscheller, G. (2007) · Brain Research · doi:10.1016/j.brainres.2006.12.052 · Cited by 177
Nolta, N. F., Christensen, M. B., Crane, P. D., Skousen, J. L., & Tresco, P. A. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.081 · Cited by 175
“cursors [1] and multiple degree-of-freedom robotic arms [2] with conscious thought.”
BackgroundCombining Decoder Design and Neural Adaptation in Brain-Machine Interfaces
Shenoy, K. V., & Carmena, J. M. (2014) · Neuron · doi:10.1016/j.neuron.2014.08.038 · Cited by 177
“Neurosci., abstract; Hochberg et al., 2006, 2012; Kim et al., 2008, 2011; Nuyujukian et al., 2014, Soc.”
Cunningham, J. P., Nuyujukian, P., Gilja, V., Chestek, C. A., Ryu, S. I., & Shenoy, K. V. (2011) · Journal of Neurophysiology · doi:10.1152/jn.00503.2010 · Cited by 176
“Alhough other training paradigms have been used (Hochberg et al. 2006), we chose this simple training method to parallel existing offline and online literature.”
BackgroundMethodInfluentialBrain-Computer Interfacing: An Introduction
Rao, R. P. N. (2013) · Cited by 186
Hatsopoulos, N. G., & Suminski, A. J. (2011) · Neuron · doi:10.1016/j.neuron.2011.10.020 · Cited by 177
“, 2006) and human subjects (Hochberg et al., 2006; Truccolo et al., 2008) to successfully use BMIs with neural decoders that were trained using the neural responses evoked during mental rehearsal/ action observation or motor imagery.”
Coadaptive Brain–Machine Interface via Reinforcement Learning
DiGiovanna, J., Mahmoudi, B., Fortes, J., Principe, J. C., & Sanchez, J. C. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.926699 · Cited by 174
“interpretation of brain processes involved in communication and control tasks for able bodied [13] or disabled individuals [14].”
BackgroundHe, W., McConnell, G. C., & Bellamkonda, R. V. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/009 · Cited by 177
“These micromachined neural prosthetic devices have been used to stimulate and record from the central and peripheral nervous systems [7–10].”
MethodMulti-Modal Sensing Techniques for Interfacing Hand Prostheses: A Review
Fang, Y., Hettiarachchi, N., Zhou, D., & Liu, H. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2450211 · Cited by 172
“A type of intracortical microelectrode array (4 mm × 4 mm, Blackrock Microsystems, Salt Lake City, UT, USA) has been used to record neural signals in [87], [100], and [101].”
BackgroundMethodZhuang, J., Truccolo, W., Vargas-Irwin, C., & Donoghue, J. P. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2047015 · Cited by 174
Self-citationHighly Stretchable Gold Nanobelts with Sinusoidal Structures for Recording Electrocorticograms
Qi, D., Liu, Z., Yu, M., Liu, Y., Tang, Y., Lv, J., Li, Y., Wei, J., Liedberg, B., Yu, Z., et al. (2015) · Advanced Materials · doi:10.1002/adma.201405807 · Cited by 175
How Many People Could Use an SSVEP BCI?
Guger, C., Allison, B. Z., Großwindhager, B., Prückl, R., Hintermüller, C., Kapeller, C., Bruckner, M., Krausz, G., & Edlinger, G. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00169 · Cited by 176
Control of a brain–computer interface without spike sorting
Fraser, G. W., Chase, S. M., Whitford, A., & Schwartz, A. B. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/055004 · Cited by 168
A Low-Power Integrated Bioamplifier With Active Low-Frequency Suppression
Gosselin, B., Sawan, M., & Chapman, C. A. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.914490 · Cited by 174
Onose, G., Grozea, C., Anghelescu, A., Daia, C., Sinescu, C. J., Ciurea, A. V., Spircu, T., Mirea, A., Andone, I., Spânu, A., et al. (2012) · Spinal Cord · doi:10.1038/sc.2012.14 · Cited by 168
Orsborn, A. L., Dangi, S., Moorman, H. G., & Carmena, J. M. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2185066 · Cited by 170
Winslow, B. D., Christensen, M. B., Yang, W.-K., Solzbacher, F., & Tresco, P. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.05.050 · Cited by 171
“Implanted recording electrodes have aided our understanding of the functional organization of the mammalian nervous system, and appear to become increasingly used to treat CNS related disabilities [1,2].”
Hand Knob Area of Premotor Cortex Represents the Whole Body in a Compositional Way
Willett, F. R., Deo, D. R., Avansino, D. T., Rezaii, P., Hochberg, L. R., Henderson, J. M., & Shenoy, K. V. (2020) · Cell · doi:10.1016/j.cell.2020.02.043 · Cited by 171
“Neural signals were recorded from the microelectrode arrays using the NeuroPort system (Blackrock Microsystems) [Hochberg, 2006 describes the basic setup].”
MethodSelf-citationOn-line, voluntary control of human temporal lobe neurons
Cerf, M., Thiruvengadam, N., Mormann, F., Kraskov, A., Quiroga, R. Q., Koch, C., & Fried, I. (2010) · Nature · doi:10.1038/nature09510 · Cited by 171
Moghimi, S., Kushki, A., Marie Guerguerian, A., & Chau, T. (2013) · Assistive Technology · doi:10.1080/10400435.2012.723298 · Cited by 166
Cortical control of a tablet computer by people with paralysis
Nuyujukian, P., Albites Sanabria, J., Saab, J., Pandarinath, C., Jarosiewicz, B., Blabe, C. H., Franco, B., Mernoff, S. T., Eskandar, E. N., Simeral, J. D., et al. (2018) · PLOS ONE · doi:10.1371/journal.pone.0204566 · Cited by 170
Self-citationArtificial intelligence in healthcare and medicine: promises, ethical challenges and governance
Guan, J. (2019) · Chinese Medical Sciences Journal · doi:10.24920/003611 · Cited by 170
“21 “Neurobiohybridization,” which refers to interfacing brain-inspired devices with the real human brain, has been established as a possibility.”
Technology Insight: future neuroprosthetic therapies for disorders of the nervous system
Normann, R. A. (2007) · Nature Clinical Practice Neurology · doi:10.1038/ncpneuro0556 · Cited by 167
A regularized discriminative framework for EEG analysis with application to brain–computer interface
Tomioka, R., & Müller, K.-R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.07.045 · Cited by 167
“This can help people who have damage in their peripheral pathway to recover their communication abilities (e.g. Birbaumer et al. (1999); Kübler et al. (2001); Nicolelis (2003); Hochberg et al. (2006)).”
BackgroundIntegrated circuit amplifiers for multi-electrode intracortical recording
Jochum, T., Denison, T., & Wolf, P. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/1/012001 · Cited by 167
Single-Neuron Stability during Repeated Reaching in Macaque Premotor Cortex
Chestek, C. A., Batista, A. P., Santhanam, G., Yu, B. M., Afshar, A., Cunningham, J. P., Gilja, V., Ryu, S. I., Churchland, M. M., & Shenoy, K. V. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.0959-07.2007 · Cited by 174
“(2005), and Hochberg et al. (2006) with small differences:”
Polymer integration for packaging of implantable sensors
Qin, Y., Howlader, M. M. R., Deen, M. J., Haddara, Y. M., & Selvaganapathy, P. R. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.05.063 · Cited by 163
Azin, M., Guggenmos, D. J., Barbay, S., Nudo, R. J., & Mohseni, P. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2108770 · Cited by 164
“Cortical control of the movement of a prosthetic arm or mouse cursor on a computer screen using brain electrical signals have indeed been successfully demonstrated in non-human primates and even in case studies in humans suffering from high-level spinal cord injury [1]–[3].”
Ofner, P., Schwarz, A., Pereira, J., Wyss, D., Wildburger, R., & Müller-Putz, G. R. (2019) · Scientific Reports · doi:10.1038/s41598-019-43594-9 · Cited by 166
Commanding a Brain-Controlled Wheelchair Using Steady-State Somatosensory Evoked Potentials
Kim, K.-T., Suk, H.-I., & Lee, S.-W. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2597854 · Cited by 166
“2597854 drink water by steering a robot arm [4], [5], communicate by”
BackgroundSchrier, J. E., Harper, J. S., Hankinson, G. J., Hulsebos, L., Povar, M. L., Mathiesen, E., & Schrier, A. M. (2009) · Cited by 166
Electrophysiological correlates of the BOLD signal for EEG-informed fMRI
Murta, T., Leite, M., Carmichael, D. W., Figueiredo, P., & Lemieux, L. (2015) · Human Brain Mapping · doi:10.1002/hbm.22623 · Cited by 165
“…assumptions (for a review, see Michel et al. [2004]), and can be categorised as: (i) overdetermined (dipolar) models [e.g., Gulrajani et al., 1984; Homma et al., 1990; Kavanagh et al., 1978; Scherg and Von Cramon, 1986; Stok, 1987], based on the assumption that a small and known number of current…”
BackgroundSimeral, J. D., Hosman, T., Saab, J., Flesher, S. N., Vilela, M., Franco, B., Kelemen, J. N., Brandman, D. M., Ciancibello, J. G., Rezaii, P. G., et al. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3069119 · Cited by 165
“Each participant completed two sessions (T10 trial days 355, 361; T5 days 560, 572) in which cabled versus wireless cursor performance was assessed in a series of interleaved back-to-back point-and-select Grid Tasks described previously [1], [7], [29].”
BackgroundMethodSelf-citationIntegrated wireless neural interface based on the Utah electrode array
Kim, S., Bhandari, R., Klein, M., Negi, S., Rieth, L., Tathireddy, P., Toepper, M., Oppermann, H., & Solzbacher, F. (2009) · Biomedical Microdevices · doi:10.1007/s10544-008-9251-y · Cited by 165
Patel, P. R., Na, K., Zhang, H., Kozai, T. D. Y., Kotov, N. A., Yoon, E., & Chestek, C. A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/046009 · Cited by 162
Microphysiology of Epileptiform Activity in Human Neocortex
Schevon, C. A., Ng, S. K., Cappell, J., Goodman, R. R., McKhann, G., Waziri, A., Branner, A., Sosunov, A., Schroeder, C. E., & Emerson, R. G. (2008) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e31818e8010 · Cited by 162
“In addition, the Neuroport system performs online action potential detection (Hochberg et al., 2006); a display of unit activity for each channel, located in the patient’s room and remotely accessible by the investigators, served as a real-time monitor of data integrity, allowing recording problems to be remedied quic…”
InfluentialSelf-citationKim, S.-P., Simeral, J. D., Hochberg, L. R., Donoghue, J. P., Friehs, G. M., & Black, M. J. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2107750 · Cited by 160
“Importantly, other work has found that hand and arm information is intermingled within the MI arm region, as sampled by this sensor [13], [33].”
InfluentialSelf-citationAzemi, E., Lagenaur, C. F., & Cui, X. T. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.09.033 · Cited by 164
“These technologies are currently at the early stage of human clinical trials [2-7] and are designed as assistive means intended to help patients suffering from spinal”
Quantifying long-term microelectrode array functionality using chronic in vivo impedance testing
Prasad, A., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026028 · Cited by 157
Optimal spacing of surface electrode arrays for brain–machine interface applications
Slutzky, M. W., Jordan, L. R., Krieg, T., Chen, M., Mogul, D. J., & Miller, L. E. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026004 · Cited by 161
“single- and multi-unit action potentials (spikes) [3, 13, 14].”
Mollazadeh, M., Murari, K., Cauwenberghs, G., & Thakor, N. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2005297 · Cited by 160
“[36] demonstrated control of a prosthetic device using an ensemble of neuronal activity recorded from the primary motor cortex.”
MethodPower-Efficient Impedance-Modulation Wireless Data Links for Biomedical Implants
Mandal, S., & Sarpeshkar, R. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2005295 · Cited by 159
“In implanted systems with many neural recording electrodes [14], the data rate from the implanted system to an external unit can be quite high since each electrode typically requires at least 5 kHz of bandwidth.”
BackgroundBarrese, J. C., Aceros, J., & Donoghue, J. P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026003 · Cited by 161
“These neural signals are transmitted to a computer that interprets the data, and converts it into a functional output [2, 3].”
BackgroundSelf-citationBrain–machine interface via real-time fMRI: Preliminary study on thought-controlled robotic arm
Lee, J.-H., Ryu, J., Jolesz, F. A., Cho, Z.-H., & Yoo, S.-S. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2008.11.024 · Cited by 156
“Translation of brain activity into direct control of mechanical hardware or computer components without the involvement of the peripheral nervous system or muscle is sought after to provide control options for paraplegic patients, to apply to consumer electronics products, and for use in other applications [4,12,18].”
Flexible Electrodes for In Vivo and In Vitro Electrophysiological Signal Recording
Zhu, M., Wang, H., Li, S., Liang, X., Zhang, M., Dai, X., & Zhang, Y. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100646 · Cited by 171
Bio-inspired electronics: Soft, biohybrid, and “living” neural interfaces
Boufidis, D., Garg, R., Angelopoulos, E., Cullen, D. K., & Vitale, F. (2025) · Nature Communications · doi:10.1038/s41467-025-57016-0 · Cited by 201
“An early demonstration of invasive interfaces implanted into a human participant was fi rst reported in 1998 15 , followed by successful demonstrations of human BCIs with Utah microelectrode arrays (MEAs) in the fi rst BrainGate trials in the early 2000s 16,17 .”
Biocompatibility of intracortical microelectrodes: current status and future prospects
Marin, C. (2010) · Frontier in Neuroengineering · doi:10.3389/fneng.2010.00008 · Cited by 160
“Moreover advances in artificial limbs and brain-machine interfaces are now providing hope of increased mobility and independence for amputees and paralyzed patients and there is preliminary data showing that by using electrophysiological methods it is possible to extract information about intentional brain processes a…”
Challenges and Opportunities for Next-Generation Intracortically Based Neural Prostheses
Gilja, V, Chestek, C. A., Diester, I., Henderson, J. M., Deisseroth, K., & Shenoy, K. V. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2107553 · Cited by 154
Mixture of Trajectory Models for Neural Decoding of Goal-Directed Movements
Yu, B. M., Kemere, C., Santhanam, G., Afshar, A., Ryu, S. I., Meng, T. H., Sahani, M., & Shenoy, K. V. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00482.2006 · Cited by 155
“…was adopted in studies using multi-electrode neural recordings in monkeys (Carmena et al. 2003; Serruya et al. 2002; Taylor et al. 2002) and humans (Hochberg et al. 2006) and both electroencephalographic (EEG) (Wolpaw and McFarland 2004) and electrocortico-graphic (ECoG) (Leuthardt et al. 2004)…”
BackgroundMethodInfluential3D Parylene sheath neural probe for chronic recordings
Kim, B. J., Kuo, J. T. W., Hara, S. A., Lee, C. D., Yu, L., Gutierrez, C. A., Hoang, T. Q., Pikov, V, & Meng, E. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/045002 · Cited by 155
“The UEA consists of tapered-tip silicon needles insulated in a polymer, with exposed platinum electrodes at the tip and has found success in cats [8], nonhuman primates [9], as well as human subjects [10].”
BackgroundIn vivo deployment of mechanically adaptive nanocomposites for intracortical microelectrodes
Harris, J. P., Hess, A. E., Rowan, S. J., Weder, C., Zorman, C. A., Tyler, D. J., & Capadona, J. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046010 · Cited by 151
Rao, L., Zhou, H., Li, T., Li, C., & Duan, Y. Y. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.03.001 · Cited by 171
“The success of cochlear implants and DBS has promoted the research and development of other kinds of neuroprosthetic devices for clinical practice, such as visual prosthetics and brain–computer interfaces [4–6].”
BackgroundAccess to AAC: Present, past, and future
Higginbotham, D. J., Shane, H., Russell, S., & Caves, K. (2007) · Augmentative and Alternative Communication · doi:10.1080/07434610701571058 · Cited by 151
Chapter 8 Neurofeedback and Brain–Computer Interface
Birbaumer, N., Ramos‐Murguialday, A., Weber, C., & Montoya, P. (2009) · International review of neurobiology · doi:10.1016/s0074-7742(09)86008-x · Cited by 180
Distributed cortical adaptation during learning of a brain–computer interface task
Wander, J. D., Blakely, T., Miller, K. J., Weaver, K. E., Johnson, L. A., Olson, J. D., Fetz, E. E., Rao, R. P. N., & Ojemann, J. G. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1221127110 · Cited by 157
“This modulation can occur in the absence of overt movement (6, 9) or even when overt movement is not possible (3, 10).”
BackgroundDetecting Neural-State Transitions Using Hidden Markov Models for Motor Cortical Prostheses
Kemere, C., Santhanam, G., Yu, B. M., Afshar, A., Ryu, S. I., Meng, T. H., & Shenoy, K. V. (2008) · Journal of Neurophysiology · doi:10.1152/jn.00924.2007 · Cited by 157
Learning to move machines with the mind
Green, A. M., & Kalaska, J. F. (2010) · Trends in Neurosciences · doi:10.1016/j.tins.2010.11.003 · Cited by 177
Spatial characterization of interictal high frequency oscillations in epileptic neocortex
Schevon, C. A., Trevelyan, A. J., Schroeder, C. E., Goodman, R. R., McKhann, G., & Emerson, R. G. (2009) · Brain · doi:10.1093/brain/awp222 · Cited by 150
“The MEA was implanted into flat surfaces of exposed neocortical gyri through the pia mater using a pneumatic insertion technique (for more details, see Suner et al., 2005; Hochberg et al., 2006; Waziri et al., 2009).”
MethodRapid calibration of an intracortical brain–computer interface for people with tetraplegia
Brandman, D. M., Hosman, T., Saab, J., Burkhart, M. C., Shanahan, B. E., Ciancibello, J. G., Sarma, A. A., Milstein, D. J., Vargas-Irwin, C. E., Franco, B., et al. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9ee7 · Cited by 153
Self-citationElectrocorticographic amplitude predicts finger positions during slow grasping motions of the hand
Acharya, S., Fifer, M. S., Benz, H. L., Crone, N. E., & Thakor, N. V. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/4/046002 · Cited by 150
A chronic generalized bi-directional brain–machine interface
Rouse, A. G., Stanslaski, S. R., Cong, P., Jensen, R. M., Afshar, P., Ullestad, D., Gupta, R., Molnar, G. F., Moran, D. W., & Denison, T. J. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036018 · Cited by 155
“For instance, while BMI prosthesis systems have shown promising results in small clinical experiments [14], the practical issues associated with chronic deployment such as implantation technique, reliability of components, chronic signal integrity and power consumption remain largely unaddressed [15].”
Metadata
- Authors
- Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P.
- Affiliations
- Brigham and Women's Hospital (US)
- Brown University (US)
- Cyberkinetics (United States) (US)
- Shirley Ryan AbilityLab (US)
- University of Chicago (US)
- Corresponding author
- Donoghue, John P.
- Venue
- Nature
- Published
- 2006-07
- Volume
- 442
- Issue
- 7099
- Pages
- 164-171
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2114004602
- Cited by
- 3,295
- References
- 47
- Citations by year
- 2026: 63 · 2025: 131 · 2024: 113 · 2023: 117 · 2022: 119 · 2021: 158 · 2020: 129 · 2019: 150 · 2018: 150 · 2017: 143 · 2016: 186 · 2015: 169 · 2014: 226 · 2013: 231 · 2012: 199
- FWCI
- 93.11
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Keywords
- tetraplegia, spinal cord injury, brain-computer interface, neuronal ensembles, primary motor cortex, intracortical microelectrode arrays, prosthetic hand control, robotic arm control, movement intention decoding, cervical spinal cord injury, upper limb paralysis
- MeSH terms
- Adult, Bionics, Electrodes, Humans, Male, Middle Aged, Movement, Quadriplegia, Robotics, User-Computer Interface, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.