Neuronal ensemble control of prosthetic devices by a human with tetraplegia
The DOI matches its Crossref record; 46 of the 47 references it cites were found in a registry or an index.
Abstract
Neuromotor prostheses (NMPs) aim to replace or restore lost motor functions in paralysed humans by routeing movement-related signals from the brain, around damaged parts of the nervous system, to external effectors. To translate preclinical results from intact animals to a clinically useful NMP, movement signals must persist in cortex after spinal cord injury and be engaged by movement intent when sensory inputs and limb movement are long absent. Furthermore, NMPs would require that intention-driven neuronal activity be converted into a control signal that enables useful tasks. Here we show initial results for a tetraplegic human (MN) using a pilot NMP. Neuronal ensemble activity recorded through a 96-microelectrode array implanted in primary motor cortex demonstrated that intended hand motion modulates cortical spiking patterns three years after spinal cord injury. Decoders were created, providing a 'neural cursor' with which MN opened simulated e-mail and operated devices such as a television, even while conversing. Furthermore, MN used neural control to open and close a prosthetic hand, and perform rudimentary actions with a multi-jointed robotic arm. These early results suggest that NMPs based upon intracortical neuronal ensemble spiking activity could provide a valuable new neurotechnology to restore independence for humans with paralysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Subcutaneous invasive electrophysiological signals can be derived through brain interfaces,[270–272] using electrocorticography (ECoG)[273,274] on the cortical surface as well as local field potentials (LFP)[275,276] extracted from electrodes inserted into the cortex.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [276]
In the citing paper
“Currently, all reported BMI experiments with human patients [26, 35, 57, 58, 150] require the subjects tethered percutaneously to a bench-top computer for neural signal acquisition and decoding.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [57]
In the citing paper
“Additionally, it is apparent from previous work that access to sufficiently large patient populations for concrete and statistically significant conclusions may be difficult to obtain (1–5, 8, 11, 29, 39).”
From Noninvasive neuroimaging enhances continuous neural tracking for robotic device control (2019) · cites this paper as [29]
Citations
Cites
Plum, F. (1960) · Archives of Neurology · doi:10.1001/archneur.1960.03840090124020 · Cited by 10,364
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Georgopoulos, A., Kalaska, J., Caminiti, R., & Massey, J. (1982) · The Journal of Neuroscience · doi:10.1523/jneurosci.02-11-01527.1982 · Cited by 2,130
International Standards for Neurological and Functional Classification of Spinal Cord Injury
Maynard, F. M., Bracken, M. B., Creasey, G., Jr, J. F. D., Donovan, W. H., Ducker, T. B., Garber, S. L., Marino, R. J., Stover, S. L., Tator, C. H., et al. (1997) · Spinal Cord · doi:10.1038/sj.sc.3100432 · Cited by 2,048
Advances in Neural Information Processing Systems 18
Murray, I., Mackay, D., Zoubin Ghahramani, A., & Skilling, J. (2006) · Cited by 1,927
Localization of the motor hand area to a knob on the precentral gyrus. A new landmark
Yousry, T. (1997) · Brain · doi:10.1093/brain/120.1.141 · Cited by 1,837
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Ditunno, J. F., Young, W., Donovan, W. H., & Creasey, G. (1994) · Spinal Cord · doi:10.1038/sc.1994.13 · Cited by 1,643
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Cited by
Items 301–400 of 1,022
Bansal, A. K., Vargas-Irwin, C. E., Truccolo, W., & Donoghue, J. P. (2011) · Journal of Neurophysiology · doi:10.1152/jn.00532.2010 · Cited by 148
“…from penetrating microelectrodes, provide a command signal that has been used by monkeys (Serruya et al. 2002; Taylor et al. 2002; Carmena et al. 2003; Velliste et al. 2008) and also by paralyzed humans (Hochberg et al. 2006) to control virtual cursors and physical devices, such as a robotic arm.”
BackgroundSelf-citationRelationship between speed and EEG activity during imagined and executed hand movements
Yuan, H., Perdoni, C., & He, B. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026001 · Cited by 153
Acute human brain responses to intracortical microelectrode arrays: challenges and future prospects
Fernández, E., Greger, B., House, P. A., Aranda, I., Botella, C., Albisua, J., Soto-Sánchez, C., Alfaro, A., & Normann, R. A. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00024 · Cited by 141
Clinical Neurorestorative Therapeutic Guidelines for Spinal Cord Injury (IANR/CANR version 2019)
Huang, H., Young, W., Skaper, S. D., Chen, L., Moviglia, G. A., Saberi, H., Zoubi, Z. M. A., Sharma, H. S., Muresanu, D. F., Sharma, A. K., et al. (2019) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2019.10.006 · Cited by 180
Aszmann, O. C., Roche, A. D., Salminger, S., Paternostro-Sluga, T., Herceg, M., Sturma, A., Hofer, C., & Farina, D. (2015) · The Lancet · doi:10.1016/s0140-6736(14)61776-1 · Cited by 152
Clausen, J. (2009) · Nature · doi:10.1038/4571080a · Cited by 152
Monitoring spike train synchrony
Kreuz, T., Chicharro, D., Houghton, C. J., Andrzejak, R. G., & Mormann, F. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00873.2012 · Cited by 181
Cortical Representation of Ipsilateral Arm Movements in Monkey and Man
Ganguly, K., Secundo, L., Ranade, G., Orsborn, A., Chang, E. F., Dimitrov, D. F., Wallis, J. D., Barbaro, N. M., Knight, R. T., & Carmena, J. M. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.2471-09.2009 · Cited by 147
“As in past studies, feedback and learning during closed-loop control were important for improvements in task performance over the course of a session (Taylor et al., 2002; Carmena et al., 2003; Hochberg et al., 2006; Mulliken et al., 2008).”
ResultMechanical and Biological Interactions of Implants with the Brain and Their Impact on Implant Design
Prodanov, D., & Delbeke, J. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00011 · Cited by 147
“Recently, Saxena et al. (2013) monitored the status of the blood-brain barrier (BBB) and the consequences of BBB breach on electrode function using non-invasive imaging, electrophysiology, genomic, and histological analyses.”
BackgroundChaudhary, U., Vlachos, I., Zimmermann, J. B., Espinosa, A., Tonin, A., Jaramillo-Gonzalez, A., Khalili-Ardali, M., Topka, H., Lehmberg, J., Friehs, G. M., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-28859-8 · Cited by 139
Self-citationNeuroimaging-based approaches in the brain–computer interface
Min, B.-K., Marzelli, M. J., & Yoo, S.-S. (2010) · Trends in Biotechnology · doi:10.1016/j.tibtech.2010.08.002 · Cited by 150
“As a result, neural firing patterns associated with a motor imagery task successfully created multi-dimensional computer cursor movement after closed-loop training [4].”
BackgroundChapman, C. A. R., Chen, H., Stamou, M., Biener, J., Biener, M. M., Lein, P. J., & Seker, E. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b00410 · Cited by 149
He, B., Yuan, H., Meng, J., & Gao, S. (2020) · Springer eBooks · doi:10.1007/978-3-030-43395-6_4 · Cited by 168
Intracortical recording stability in human brain–computer interface users
Downey, J. E., Schwed, N., Chase, S. M., Schwartz, A. B., & Collinger, J. L. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab7a0 · Cited by 149
Nanofabricated Ultraflexible Electrode Arrays for High‐Density Intracortical Recording
Wei, X., Luan, L., Zhao, Z., Li, X., Zhu, H., Potnis, O., & Xie, C. (2018) · Advanced Science · doi:10.1002/advs.201700625 · Cited by 146
Learning a Novel Myoelectric-Controlled Interface Task
Radhakrishnan, S. M., Baker, S. N., & Andrew, J. O. (2008) · Journal of Neurophysiology · doi:10.1152/jn.90614.2008 · Cited by 157
“All gave informed consent according to procedures approved by the local ethics committee.”
Stable long-term BCI-enabled communication in ALS and locked-in syndrome using LFP signals
Milekovic, T., Sarma, A. A., Bacher, D., Simeral, J. D., Saab, J., Pandarinath, C., Sorice, B. L., Blabe, C., Oakley, E. M., Tringale, K. R., et al. (2018) · Journal of Neurophysiology · doi:10.1152/jn.00493.2017 · Cited by 137
“1997) using a previously described procedure (Hochberg et al. 2006).”
MethodSelf-citation(2016) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2512935 · Cited by 145
Li, Z., Yuan, Y., Luo, L., Su, W., Zhao, K., Xu, C., Huang, J., & Pi, M. (2019) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2019.2949865 · Cited by 153
“Recent studies on BCI-based control have made great development, for example the EEGbased controlled virtual cursors on the screens, prosthesis and other external assistive devices [19]–[25].”
BackgroundA Low-Power 32-Channel Digitally Programmable Neural Recording Integrated Circuit
Wattanapanitch, W., & Sarpeshkar, R. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2163404 · Cited by 146
“Digital Object Identifier 10.1109/TBCAS.2011.2163404 clinical trial in a human subject [6] illustrated that control signals directly derived from spiking activities from a population of neurons in the cortical area of the brain can be used to successfully control and manipulate computer devices or…”
InfluentialA Review of Emerging Access Technologies for Individuals With Severe Motor Impairments
Tai, K., Blain, S., & Chau, T. (2008) · Assistive Technology · doi:10.1080/10400435.2008.10131947 · Cited by 148
“, 1999), recent studies suggest that intracortical recordings can support BCIs that: 1) provide greater degrees of freedom than EEG and ECoG-based BCIs; and 2) facilitate voluntary control while the user is performing other motor or cognitive tasks (Hochberg et al., 2006).”
BackgroundInfluentialBoendermaker, S. H., Funk, M., Summers, P. E., Brugger, P., Hepp‐Reymond, M., Curt, A. E. P., & Kollias, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.07.065 · Cited by 164
“It further provides the principal physiological requirements for the development of a brain–computer interface device that uses intention-driven neuronal activity to be converted into a control signal that enables useful tasks (Hochberg et al., 2006).”
BackgroundOrtiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-33 · Cited by 144
“A review of intrafascicular electrodes with focus on the central nervous system (CNS) is given by Cheung in [9].”
BackgroundMethodInfluentialA hybrid ERD/SSVEP BCI for continuous simultaneous two dimensional cursor control
Allison, B. Z., Brunner, C., Altstätter, C., Wagner, I. C., Grissmann, S., & Neuper, C. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.06.022 · Cited by 155
Swann, N. C., de Hemptinne, C., Miocinovic, S., Qasim, S., Ostrem, J. L., Galifianakis, N. B., Luciano, M. S., Wang, S. S., Ziman, N., Taylor, R., et al. (2018) · Journal of Neurosurgery · doi:10.3171/2016.11.jns161162 · Cited by 143
Chandrakumar, H., & Markovic, D. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2876468 · Cited by 134
Translational opportunities and challenges of invasive electrodes for neural interfaces
Shen, K., Chen, O., Edmunds, J. L., Piech, D. K., & Maharbiz, M. M. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01021-5 · Cited by 160
3D-nanostructured boron-doped diamond for microelectrode array neural interfacing
Piret, G., Hébert, C., Mazellier, J.-P., Rousseau, L., Scorsone, E., Cottance, M., Lissorgues, G., Heuschkel, M. O., Picaud, S., Bergonzo, P., et al. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.021 · Cited by 135
Movement: How the Brain Communicates with the World
Schwartz, A. B. (2016) · Cell · doi:10.1016/j.cell.2016.02.038 · Cited by 132
“, 2000) and paralyzed humans (Hochberg et al., 2006; Kennedy et al., 2000) controlling a cursor on a computer screen.”
The Tongue Enables Computer and Wheelchair Control for People with Spinal Cord Injury
Kim, J., Park, H., Bruce, J. A., Sutton, E., Rowles, D. M., Pucci, D., Holbrook, J. S., Minocha, J., Nardone, B., West, D. P., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3006296 · Cited by 141
“They provide environmental access for individuals with very limited motor control (11).”
BackgroundGolabchi, A., Wu, B., Cao, B., Bettinger, C. J., & Cui, X. T. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119519 · Cited by 136
Wearable and Implantable Electroceuticals for Therapeutic Electrostimulations
Long, Y., Li, J., Yang, F., Wang, J., & Wang, X. (2021) · Advanced Science · doi:10.1002/advs.202004023 · Cited by 149
Noninvasive brain-computer interface enables communication after brainstem stroke
Sellers, E. W., Ryan, D. B., & Hauser, C. K. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3007801 · Cited by 140
“A BCI operates by translating volitional modulation of brain signals into computer commands, which can be recorded from the scalp using electroencephalography (EEG) (4), from the dura mater or cortical surface using electrocorticography (ECoG) (5), or from cortical neurons (6).”
MethodNguyen-Vu, T. D. B., Chen, H., Cassell, A. M., Andrews, R. J., Meyyappan, M., & Li, J. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.891169 · Cited by 140
Recent Advances in Neural Recording Microsystems
Gosselin, B. (2011) · Sensors · doi:10.3390/s110504572 · Cited by 138
“The characterization of hand trajectory has also been investigated [8], and the potential of neural prosthetic devices for helping paralyzed humans has also been clearly demonstrated [9].”
BackgroundPohlmeyer, E. A., Oby, E. R., Perreault, E. J., Solla, S. A., Kilgore, K. L., Kirsch, R. F., & Miller, L. E. (2009) · PLoS ONE · doi:10.1371/journal.pone.0005924 · Cited by 136
“It is worth noting that the multi-electrode array used here to record neural activity from the monkeys’ brains has been implanted in a small number of human patients [12].”
BackgroundBrain-machine interfaces for rehabilitation in stroke: A review
López‐Larraz, E., Sarasola-Sanz, A., Irastorza-Landa, N., Birbaumer, N., & Ramos‐Murguialday, A. (2018) · Neurorehabilitation · doi:10.3233/nre-172394 · Cited by 158
Xie, X., Rieth, L., Williams, L., Negi, S., Bhandari, R., Caldwell, R., Sharma, R., Tathireddy, P., & Solzbacher, F. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026016 · Cited by 137
Eid, M. A., Giakoumidis, N., & Saddik, A. E. (2016) · IEEE Access · doi:10.1109/access.2016.2520093 · Cited by 138
“paralysis [2], but they are prone to motion artifacts and interferences, and cannot be easily adapted to daily activities [3].”
Müller-Putz, G. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63934-9.00018-4 · Cited by 174
A floating metal microelectrode array for chronic implantation
Musallam, S., Bak, M. J., Troyk, P. R., & Andersen, R. A. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.09.005 · Cited by 149
HermesB: A Continuous Neural Recording System for Freely Behaving Primates
Santhanam, G., Linderman, M. D., Gilja, V., Afshar, A., Ryu, S. I., Meng, T. H., & Shenoy, K. V. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.895753 · Cited by 136
“This implant has been adopted by many electrophysiology research laboratories and is now FD A approved for clinical trials with humans [6].”
BackgroundMethodHow inhibition influences seizure propagation
Trevelyan, A. J., & Schevon, C. A. (2012) · Neuropharmacology · doi:10.1016/j.neuropharm.2012.06.015 · Cited by 144
“Recently, several groups have reported on recordings made in small numbers of patients implanted with multi-electrode arrays, which sample from up to 96 electrodes arranged within a 4 4 mm space (Hochberg et al., 2006; House et al., 2006; Schevon et al., 2009; Waziri et al., 2009).”
BackgroundChase, S. M., Schwartz, A. B., & Kass, R. E. (2009) · Neural Networks · doi:10.1016/j.neunet.2009.05.005 · Cited by 135
Human brain mapping with multithousand-channel PtNRGrids resolves spatiotemporal dynamics
Tchoe, Y., Bourhis, A. M., Cleary, D. R., Stedelin, B., Lee, J., Tonsfeldt, K. J., Brown, E. C., Siler, D. A., Paulk, A. C., Yang, J. C., et al. (2022) · Science Translational Medicine · doi:10.1126/scitranslmed.abj1441 · Cited by 135
Clinical applications of penetrating neural interfaces and Utah Electrode Array technologies
Normann, R. A., & Fernandez, E. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/061003 · Cited by 135
“These signals can be used to extract and interpret intentional brain derived commands for fine-grained control of external devices (Hochberg et al 2006, Andersen et al 2010, Hochberg et al 2012, Collinger et al 2013, Rao and Donoghue 2014, Aflalo et al 2015, Gilja et al 2015).”
BackgroundEvolution of brain-computer interfaces: going beyond classic motor physiology
Leuthardt, E. C., Schalk, G., Roland, J. L., Rouse, A. G., & Moran, D. W. (2009) · Neurosurgical FOCUS · doi:10.3171/2009.4.focus0979 · Cited by 157
Chai, G., Sui, X., Li, S., He, L., & Lan, N. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/6/066002 · Cited by 131
Flexible fiber-based optoelectronics for neural interfaces
Park, S., Loke, G., Fink, Y., & Anikeeva, P. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00710a · Cited by 134
Brain-Computer Interface Controlled Functional Electrical Stimulation System for Ankle Movement
Do, A. H., Wang, P. T., King, C., Abiri, A., & Nenadić, Z. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-49 · Cited by 152
“[15] demonstrated how a subject with tetraplegia due to SCI could use an invasive BCI to operate a robotic arm to perform a simple task of moving an object from one point to another and to open and close a robotic hand.”
Future developments in brain-machine interface research
Lebedev, M. A., Tate, A. J., Hanson, T. L., Li, Z., O'Doherty, J. E., Winans, J. A., Ifft, P. J., Zhuang, K. Z., Fitzsimmons, N. A., Schwarz, D. A., et al. (2011) · Clinics · doi:10.1590/s1807-59322011001300004 · Cited by 130
Lin, C.-T., Ko, L.-W., Chang, M.-H., Duann, J.-R., Chen, J.-Y., Su, T.-P., & Jung, T.-P. (2010) · Gerontology · doi:10.1159/000230807 · Cited by 133
Temporal coding of brain patterns for direct limb control in humans
Mueller-Putz (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00034 · Cited by 131
Decoding hand gestures from primary somatosensory cortex using high-density ECoG
Branco, M. P., Freudenburg, Z. V., Aarnoutse, E. J., Bleichner, M. G., Vansteensel, M. J., & Ramsey, N. F. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.004 · Cited by 126
“, 1986) and human (Hochberg et al., 2006) studies that this region allows decoding of arm and hand motor movements.”
InfluentialA 100-Channel 1-mW Implantable Neural Recording IC
Zou, X., Liu, L., Cheong, J. H., Yao, L., Li, P., Cheng, M.-Y., Goh, W. L., Rajkumar, R., Dawe, G. S., Cheng, K.-W., et al. (2013) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2013.2249175 · Cited by 132
Non-Invasive Brain-to-Brain Interface (BBI): Establishing Functional Links between Two Brains
Yoo, S.-S., Kim, H., Filandrianos, E., Taghados, S. J., & Park, S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0060410 · Cited by 127
“To characterize a specific function of the brain, invasive means such as implantable cortical microelectrode arrays that directly detect the electrical field potentials/spikes from the somatomotor areas have been used, for example, to provide BCI control options for quadriplegic patients [2].”
MethodHermesC: Low-Power Wireless Neural Recording System for Freely Moving Primates
Chestek, C. A., Gilja, V., Nuyujukian, P., Kier, R. J., Solzbacher, F., Ryu, S. I., Harrison, R. R., & Shenoy, K. V. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2023293 · Cited by 130
“have demonstrated improving performance in monkeys [4]–[6] and even humans [7].”
BackgroundControl of prosthetic hands via the peripheral nervous system
Ciancio, A. L., Cordella, F., Barone, R., Romeo, R. A., Bellingegni, A. D., Sacchetti, R., Davalli, A., Di Pino, G., Ranieri, F., Di Lazzaro, V., et al. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00116 · Cited by 131
“Developed in cooperation with Dr. Todd Kuiken and NECAL laboratory at the Rehab Institute of Chicago, it is undergoing clinical trials in several US rehabilitation centers, also in conjunction with TMR. Pattern recognition offers the notable advantage of enabling the simultaneous, independent control of multiple DoFs.”
BackgroundMethodInfluentialMotor system evolution and the emergence of high cognitive functions
Mendoza, G., & Merchant, H. (2014) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2014.09.001 · Cited by 139
“, 2000), but lately also in tetraplegic human patients (Collinger et al., 2013; Hochberg et al., 2006).”
BackgroundBlending Electronics with the Human Body: A Pathway toward a Cybernetic Future
Mehrali, M., Bagherifard, S., Akbari, M., Thakur, A., Mirani, B., Mehrali, M., Hasany, M., Orive, G., Das, P., Emneus, J., et al. (2018) · Advanced Science · doi:10.1002/advs.201700931 · Cited by 124
Mind-controlled transgene expression by a wireless-powered optogenetic designer cell implant.
Folcher, M., Oesterle, S., Zwicky, K., Thekkottil, T., Heymoz, J., Hohmann, M., Christen, M., Daoud El-Baba, M., Buchmann, P., & Fussenegger, M. (2014) · Nature Communications · doi:10.1038/ncomms6392 · Cited by 130
Adaptive Decoding for Brain-Machine Interfaces Through Bayesian Parameter Updates
Li, Z., O'Doherty, J. E., Lebedev, M. A., & Nicolelis, M. A. L. (2011) · Neural Computation · doi:10.1162/neco_a_00207 · Cited by 128
“…for translating recorded neuronal signals into movement commands assumed static neuronal tuning (Wessberg et al., 2000; Serruya, Hatsopoulos, Paninski, Fellows, & Donoghue , 2002; Carmena et al., 2003; Hochberg et al., 2006; Wu, Gao, Bienenstock, Donoghue, & Black, 2006; Ganguly & Carmena, 2009).”
BackgroundNeural Point-and-Click Communication by a Person With Incomplete Locked-In Syndrome
Bacher, D., Jarosiewicz, B., Masse, N. Y., Stavisky, S. D., Simeral, J. D., Newell, K., Oakley, E. M., Cash, S. S., Friehs, G., & Hochberg, L. R. (2015) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968314554624 · Cited by 124
Self-citationNeuronal ensemble control of prosthetic devices by a human with tetraplegia
Gormley, W. B. (2007) · Yearbook of Neurology and Neurosurgery · doi:10.1016/s0513-5117(08)70233-3 · Cited by 129
Hai, A., Shappir, J., & Spira, M. E. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00265.2010 · Cited by 123
“…arrays enables investigators to record and stimulate large populations of excitable cells for days and months without inflicting mechanical dam- ages to the cell plasma membrane (Berdondini et al. 2009; Hochberg et al. 2006; Hutzler et al. 2006; Rubehn et al. 2009; Shahaf et al. 2008).”
BackgroundTranslating the Brain-Machine Interface
Thakor, N. V. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007303 · Cited by 128
“Current-generation algorithms and implanted systems have demonstrated improved decoding accuracies and reliability of performance in nonhuman primates (72) and provocative outcomes in tetraplegic patients (67, 68).”
BackgroundNurmikko, A. V., Donoghue, J. P., Hochberg, L. R., Patterson, W. R., Song, Y.-K., Bull, C. W., Borton, D. A., Laiwalla, F., Park, S., Ming, Y., et al. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2038949 · Cited by 127
“Digital Object Identifier: 10.1109/JPROC.2009.2038949 Vol. 98, No. 3, March 2010 | Proceedings of the IEEE 3750018-9219/$26.00 2010 IEEE”
InfluentialSelf-citationSorger, B., Dahmen, B., Reithler, J., Gosseries, O., Maudoux, A., Laureys, S., & Goebel, R. (2009) · Progress in brain research · doi:10.1016/s0079-6123(09)17719-1 · Cited by 135
Rehabilitation and Health Care Robotics
der Loos, H. F. M. V., Reinkensmeyer, D. J., & Guglielmelli, E. (2016) · Springer handbooks · doi:10.1007/978-3-319-32552-1_64 · Cited by 146
Machado, S., Araújo, F., Paes, F., Velasques, B., Cunha, M., Budde, H., Basile, L. F., Anghinah, R., Arias-Carrión, O., Cagy, M., et al. (2010) · Reviews in the Neurosciences · doi:10.1515/revneuro.2010.21.6.451 · Cited by 124
High-density single-unit human cortical recordings using the Neuropixels probe
Chung, J. E., Sellers, K. K., Leonard, M. K., Gwilliams, L., Xu, D., Dougherty, M. E., Kharazia, V., Metzger, S. L., Welkenhuysen, M., Dutta, B., et al. (2022) · Neuron · doi:10.1016/j.neuron.2022.05.007 · Cited by 126
Plug-and-play control of a brain–computer interface through neural map stabilization
Silversmith, D. B., Abiri, R., Hardy, N. F., Natraj, N., Tu-Chan, A., Chang, E. F., & Ganguly, K. (2021) · Nature Biotechnology · doi:10.1038/s41587-020-0662-5 · Cited by 126
Gulati, T., Ramanathan, D. S., Wong, C. C., & Ganguly, K. (2014) · Nature Neuroscience · doi:10.1038/nn.3759 · Cited by 123
Curing epilepsy: Progress and future directions
Jacobs, M. P., Leblanc, G. G., Brooks‐Kayal, A. R., Jensen, F. E., Lowenstein, D. H., Noebels, J. L., Spencer, D. D., & Swann, J. W. (2009) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2009.02.036 · Cited by 148
“The arrays are used to detect activity patterns in the motor cortex associated with intentions for hand movements, which are then translated into an output that controls the movement of a computer cursor or a mechanical hand [135,136].”
Brain-Machine Interfaces beyond Neuroprosthetics
Moxon, K. A., & Foffani, G. (2015) · Neuron · doi:10.1016/j.neuron.2015.03.036 · Cited by 137
“These advances are critical for ultimately bridging the gap between more traditional neuroprosthetics on healthy animals and their translation to the clinical population (Hochberg et al., 2006, 2012; Collinger et al., 2013).”
BackgroundDifferential representation of arm movement direction in relation to cortical anatomy and function
Ball, T., Schulze-Bonhage, A., Aertsen, A., & Mehring, C. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/1/016006 · Cited by 122
The state of clinical trials of implantable brain–computer interfaces
Patrick-Krueger, K. M., Burkhart, I., & Contreras-Vidal, J. L. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00239-5 · Cited by 125
“…SCI and tetraplegia who was able to use intended hand motion to drive a computer cursor in two dimensions, simulating daily activities such as opening emails and operating a television, as well as using the intent to control a multi-joint robotic arm and opening and closing a prosthetic hand 30 .”
Chase, S. M., Kass, R. E., & Schwartz, A. B. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00371.2011 · Cited by 127
A Real-Time fMRI-Based Spelling Device Immediately Enabling Robust Motor-Independent Communication
Sorger, B., Reithler, J., Dahmen, B., & Goebel, R. (2012) · Current Biology · doi:10.1016/j.cub.2012.05.022 · Cited by 144
“, [2–7]), and BCIs based on electroencephalography (EEG) have already been applied successfully to concerned patients [8–11].”
Converging Cognitive Enhancements
Sandberg, A., & Bostrom, N. (2006) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1382.015 · Cited by 154
Rapid control and feedback rates enhance neuroprosthetic control
Shanechi, M. M., Orsborn, A. L., Moorman, H. G., Gowda, S., Dangi, S., & Carmena, J. M. (2017) · Nature Communications · doi:10.1038/ncomms13825 · Cited by 120
Herff, C., Krusienski, D. J., & Kubben, P. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00123 · Cited by 119
Active upper limb prostheses: a review on current state and upcoming breakthroughs
Marinelli, A., Boccardo, N., Tessari, F., Domenico, D. D., Caserta, G., Canepa, M., Gini, G. C., Barresi, G., Laffranchi, M., Michieli, L. D., et al. (2023) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/acac57 · Cited by 131
“The first neuroprosthetic application on humans was reported by the group of Donoghue, who demonstrated that tetraplegic individuals implanted with arrays of microelectrodes over the motor cortex were able to remotely control the movement of a cursor on a screen (Hochberg et al 2006).”
Sensors and Decoding for Intracortical Brain Computer Interfaces
Homer, M. L., Nurmikko, A. V., Donoghue, J. P., & Hochberg, L. R. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124640 · Cited by 121
“For example, when a person with paralysis used an iBCI to control a computer cursor’s motion, linear regression processed the calibration data to arrive at the needed matrices for the linear filter (23).”
Self-citationThe Microbead: A 0.009 mm3 Implantable Wireless Neural Stimulator
Khalifa, A., Liu, Y., Karimi, Y., Wang, Q., Eisape, A., Stanacevic, M., Thakor, N., Bao, Z., & Etienne-Cummings, R. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2939014 · Cited by 119
“accurately control robotic prosthetic limbs [14] or better evoke a sense of touch [15].”
BackgroundNetworking Systems of AI: On the Convergence of Computing and Communications
Song, L., Hu, X., Zhang, G., Spachos, P., Plataniotis, K. N., & Wu, H. (2022) · IEEE Internet of Things Journal · doi:10.1109/jiot.2022.3172270 · Cited by 143
“Hochberg et al. [254] implanted an electrode chip into the motor cortex of a paralyzed patient, enabling him to control the movements of household appliances, such as an electrical television and prosthetic limbs.”
BackgroundTheoretical analysis of intracortical microelectrode recordings
Lempka, S. F., Johnson, M. D., Moffitt, M. A., Otto, K. J., Kipke, D. R., & McIntyre, C. C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/045006 · Cited by 119
Micera, S., Navarro, X., Carpaneto, J., Citi, L., Tonet, O., Rossini, P. M., Carrozza, M. C., Hoffmann, K. P., Vivo, M., Yoshida, K., et al. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2006207 · Cited by 120
Physiological regulation of thinking: brain–computer interface (BCI) research
Birbaumer, N., Weber, C., Neuper, C., Buch, E. R., Haapen, K., & Cohen, L. G. (2006) · Progress in brain research · doi:10.1016/s0079-6123(06)59024-7 · Cited by 127
Behavioral Demonstration of a Somatosensory Neuroprosthesis
Berg, J. A., Dammann, J. F., Tenore, F. V., Tabot, G. A., Boback, J. L., Manfredi, L. R., Peterson, M. L., Katyal, K. D., Johannes, M. S., Makhlin, A., et al. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2244616 · Cited by 119
The Development of Brain-Machine Interface Neuroprosthetic Devices
Patil, P. G., & Turner, D. A. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.11.002 · Cited by 140
Zhang, T., Liu, T., Li, F., Li, M., Liu, D., Zhang, R., He, H., Li, P., Gong, J., Luo, C., et al. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.04.030 · Cited by 125
“Using the direct neuro-recording, several studies revealed that the primary motor cortex (M1) and posterior parietal cortex (PPC) are rich sources of MI EEG signals that can be used to control BCIs (Aflalo et al., 2015; Hochberg et al., 2006).”
BackgroundInfluentialAdvances in nanowire bioelectronics
Zhou, W., Dai, X., & Lieber, C. M. (2017) · Reports on Progress in Physics · doi:10.1088/0034-4885/80/1/016701 · Cited by 117
Single-trial decoding of movement intentions using functional ultrasound neuroimaging
Norman, S. L., Maresca, D., Christopoulos, V. N., Griggs, W. S., Demené, C., Tanter, M., Shapiro, M. G., & Andersen, R. A. (2021) · Neuron · doi:10.1016/j.neuron.2021.03.003 · Cited by 136
Herff, C., Diener, L., Angrick, M., Mugler, E., Tate, M. C., Goldrick, M. A., Krusienski, D. J., Slutzky, M. W., & Schultz, T. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.01267 · Cited by 118
“The rapid feedback of BrainTo-Speech is capable of could also enable the user to learn to operate the speech prosthesis in the future, as has been demonstrated for neural upper-limb prostheses (Hochberg et al., 2006).”
BackgroundThin films and microelectrode arrays for neuroprosthetics
Ordonez, J., Schuettler, M., Boehler, C., Boretius, T., & Stieglitz, T. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.117 · Cited by 118
Power-saving design opportunities for wireless intracortical brain–computer interfaces
Even-Chen, N., Muratore, D. G., Stavisky, S. D., Hochberg, L. R., Henderson, J. M., Murmann, B., & Shenoy, K. V. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0595-9 · Cited by 118
“In clinical motor prosthesis applications, brain–computer interfaces estimate the user’s intention from brain activity and use this ‘decoded’ intention to guide the person’s own limb 2,3 or an assistive device, such as a prosthetic arm 4–6 or a computer cursor 7–9 (Fig.”
MethodSelf-citationGeneralized Features for Electrocorticographic BCIs
Shenoy, P., Miller, K. J., Ojemann, J. G., & Rao, R. P. N. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.903528 · Cited by 116
“Although the invasive BCIs typically outperform EEG-based BCIs, there is significant concern about neural recordings in humans [6] due in part to the invasive nature of the procedure and concerns regarding long-term health risks.”
BackgroundAdvances in Neuroprosthetic Learning and Control
Carmena, J. M. (2013) · PLoS Biology · doi:10.1371/journal.pbio.1001561 · Cited by 117
“, that which uses implantable technology to record from populations of neurons) is currently done in able-bodied animal subjects [22] except for some exceptions in animal models of spinal cord injury [23], temporary models of paralysis induced via nerve blocks [9,11,12], as well as a few clinical trials in humans [7,1…”
BackgroundNeurofeedback: One of today's techniques in psychiatry?
Arns, M., Batail, J.-M., Bioulac, S., Congedo, M., Daudet, C., Drapier, D., Fovet, T., Jardri, R., Le-Van-Quyen, M., Lotte, F., et al. (2017) · L'Encéphale · doi:10.1016/j.encep.2016.11.003 · Cited by 117
Metadata
- Authors
- Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P.
- Affiliations
- Brigham and Women's Hospital (US)
- Brown University (US)
- Cyberkinetics (United States) (US)
- Shirley Ryan AbilityLab (US)
- University of Chicago (US)
- Corresponding author
- Donoghue, John P.
- Venue
- Nature
- Published
- 2006-07
- Volume
- 442
- Issue
- 7099
- Pages
- 164-171
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2114004602
- Cited by
- 3,295
- References
- 47
- Citations by year
- 2026: 63 · 2025: 131 · 2024: 113 · 2023: 117 · 2022: 119 · 2021: 158 · 2020: 129 · 2019: 150 · 2018: 150 · 2017: 143 · 2016: 186 · 2015: 169 · 2014: 226 · 2013: 231 · 2012: 199
- FWCI
- 93.11
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Keywords
- tetraplegia, spinal cord injury, brain-computer interface, neuronal ensembles, primary motor cortex, intracortical microelectrode arrays, prosthetic hand control, robotic arm control, movement intention decoding, cervical spinal cord injury, upper limb paralysis
- MeSH terms
- Adult, Bionics, Electrodes, Humans, Male, Middle Aged, Movement, Quadriplegia, Robotics, User-Computer Interface, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.