Design and validation of a foldable and photovoltaic wide-field epiretinal prosthesis
Open accessAbstract
Retinal prostheses have been developed to fight blindness in people affected by outer retinal layer dystrophies. To date, few hundred patients have received a retinal implant. Inspired by intraocular lenses, we have designed a foldable and photovoltaic wide-field epiretinal prosthesis (named POLYRETINA) capable of stimulating wireless retinal ganglion cells. Here we show that within a visual angle of 46.3 degrees, POLYRETINA embeds 2215 stimulating pixels, of which 967 are in the central area of 5 mm, it is foldable to allow implantation through a small scleral incision, and it has a hemispherical shape to match the curvature of the eye. We demonstrate that it is not cytotoxic and respects optical and thermal safety standards; accelerated ageing shows a lifetime of at least 2 years. POLYRETINA represents significant progress towards the improvement of both visual acuity and visual field with the same device, a current challenging issue in the field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures










Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Achieving this ambitious goal will certainly require the engineering of next-generation visual prostheses with large electrode counts (Ferlauto et al., 2018; Shah and Chichilnisky, 2020; Chen et al., 2020) and the development of sophisticated AI systems.”
From Towards a Smart Bionic Eye : AI-powered artificial vision for the treatment of incurable blindness (2022) · cites this paper as Ferlauto et al., 2018
In the citing paper
“POLYRETINA is a high-density wide-field epiretinal prosthesis containing 10 498 photovoltaic pixels distributed over an active area of approximately 43 • [38,39,131,132].”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [38]
In the citing paper
“To overcome this issue, POLYRETINA is a foldable and injectable photovoltaic epiretinal prosthesis that can be safely delivered with a 6 mm size cut through the sclera and conform better to the curvature of the eye [39,38].”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [38]
In the citing paper
“In particular, new developments in organic bioelectronics and photovoltaics showed superior features in conformability, flexibility and stretchability [38,39] compared to silicon-based technology.”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [38]
In the citing paper
“The fabricated polydimethylsiloxane (PDMS)-interface and of the dome-shaped PDMS enable to match with the curvature of the eye [Fig.1(e)].”
From From flexible electronics technology in the era of IoT and artificial intelligence toward future implanted body sensor networks (2019) · cites this paper as [33]
In the citing paper
“For instance, a foldable and photovoltaic wide-field epiretinal prosthesis is developed, capable of stimulating wireless retinal ganglion cells.33”
From From flexible electronics technology in the era of IoT and artificial intelligence toward future implanted body sensor networks (2019) · cites this paper as [33]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Unsupervised spike detection and sorting with wavelets and superparamagnetic clustering
Quiroga, R. Q., Nadasdy, Z., & Ben-Shaul, Y. (2004) · Neural Computation · doi:10.1162/089976604774201631 · Cited by 2,119
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Causes of vision loss worldwide, 1990–2010: a systematic analysis
Bourne, R., Stevens, G. A., White, R. A., Smith, J. L., Flaxman, S. R., Price, H., Jonas, J. B., Keeffe, J. E., Leasher, J. L., Naidoo, K. S., et al. (2013) · The Lancet Global Health · doi:10.1016/s2214-109x(13)70113-x · Cited by 1,882
Electronic dura mater for long-term multimodal neural interfaces
Minev, I. R., Musienko, P., Hirsch, A., Barraud, Q., Wenger, N., Moraud, E. M., Gandar, J., Capogrosso, M., Milekovic, T., Asboth, L., et al. (2015) · Science · doi:10.1126/science.1260318 · Cited by 1,082
Retinal degeneration mutants in the mouse
Chang, B., Hawes, N. L., Hurd, R. E., Davisson, M. T., Nusinowitz, S., & Heckenlively, J. R. (2002) · Vision Research · doi:10.1016/s0042-6989(01)00146-8 · Cited by 840
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
Maximum permissible exposures for ocular safety (ANSI 2000), with emphasis on ophthalmic devices
Delori, F. C., Webb, R. H., & Sliney, D. H. (2007) · Journal of the Optical Society of America A · doi:10.1364/josaa.24.001250 · Cited by 484
Photovoltaic retinal prosthesis with high pixel density
Mathieson, K., Loudin, J., Goetz, G. A., Huie, P., Wang, L., Kamins, T. I., Galambos, L., Smith, R., Harris, J. S., Sher, A., et al. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.104 · Cited by 460
Chang, B., Hawes, N. L., Pardue, M. T., German, A. M., Hurd, R. E., Davisson, M. T., Nusinowitz, S., Rengarajan, K., Boyd, A. P., Sidney, S. S., et al. (2007) · Vision Research · doi:10.1016/j.visres.2006.11.020 · Cited by 395
Subretinal visual implant alpha IMS - clinical trial interim report
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Chee, C. K., Cottriall, C. L., Gekeler, F., Groppe, M., Jackson, T. L., MacLaren, R. E., Koitschev, A., et al. (2015) · Vision Research · doi:10.1016/j.visres.2015.03.001 · Cited by 387
The Argus® II Retinal Prosthesis System
Luo, Y. H.-L., & da Cruz, L. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.09.003 · Cited by 351
Photovoltaic restoration of sight with high visual acuity
Lorach, H., Goetz, G., Smith, R., Lei, X., Mandel, Y., Kamins, T. I., Mathieson, K., Huie, P., Harris, J. S., Sher, A., et al. (2015) · Nature Medicine · doi:10.1038/nm.3851 · Cited by 341
Design of a high-resolution optoelectronic retinal prosthesis
Palanker, D., Vankov, A., Huie, P., & Baccus, S. A. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/012 · Cited by 330
A polymer optoelectronic interface restores light sensitivity in blind rat retinas
Ghezzi, D., Antognazza, M. R., Maccarone, R., Bellani, S., Lanzarini, E., Martino, N., Mete, M., Pertile, G., Bisti, S., Lanzani, G., et al. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.34 · Cited by 327
Self-citationA hybrid bioorganic interface for neuronal photoactivation
Ghezzi, D., Antognazza, M. R., Maschio, M. D., Lanzarini, E., Benfenati, F., & Lanzani, G. (2011) · Nature Communications · doi:10.1038/ncomms1164 · Cited by 313
Self-citationA fully organic retinal prosthesis restores vision in a rat model of degenerative blindness
Maya‐Vetencourt, J. F., Ghezzi, D., Antognazza, M. R., Colombo, E., Mete, M., Feyen, P., Desii, A., Buschiazzo, A., Paolo, M. D., Marco, S. D., et al. (2017) · Nature Materials · doi:10.1038/nmat4874 · Cited by 294
Self-citationElectrical multisite stimulation of the isolated chicken retina
Stett, A., Barth, W., Weiss, S., Haemmerle, H., & Zrenner, E. (2000) · Vision Research · doi:10.1016/s0042-6989(00)00005-5 · Cited by 259
Accelerated aging for testing polymeric biomaterials and medical devices
Hukins, D. W. L., Mahomed, A., & Kukureka, S. N. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.06.001 · Cited by 251
Mobility performance with a pixelized vision system.
Cha, K., Horch, K. W., & Normann, R. A. (1992) · Vision Research · doi:10.1016/0042-6989(92)90229-c · Cited by 226
Dorn, J. D., Ahuja, A. K., Caspi, A., da Cruz, L., Dagnelie, G., Sahel, J.-A., Greenberg, R. J., McMahon, M. J., & Argus II Study Group, F. T. (2013) · JAMA Ophthalmology · doi:10.1001/2013.jamaophthalmol.221 · Cited by 177
Improving the spatial resolution of epiretinal implants by increasing stimulus pulse duration
Weitz, A. C., Nanduri, D., Behrend, M. R., Gonzalez-Calle, A., Greenberg, R. J., Humayun, M. S., Chow, R. H., & Weiland, J. D. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aac4877 · Cited by 154
Boinagrov, D., Pangratz-Fuehrer, S., Goetz, G., & Palanker, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026008 · Cited by 146
Real and virtual mobility performance in simulated prosthetic vision
Dagnelie, G., Keane, P. A., Narla, V., Yang, L., Weiland, J. D., & Humayun, M. S. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/1/s11 · Cited by 136
Thresholds for activation of rabbit retinal ganglion cells with a subretinal electrode
Jensen, R. J., & Rizzo, J. F. (2006) · Experimental Eye Research · doi:10.1016/j.exer.2006.01.012 · Cited by 120
Bareket, L., Waiskopf, N., Rand, D., Lubin, G., David‐Pur, M., Ben-Dov, J., Roy, S., Eleftheriou, C. G., Sernagor, E., Cheshnovsky, O., et al. (2014) · Nano Letters · doi:10.1021/nl5034304 · Cited by 120
Elastomeric substrates with embedded stiff platforms for stretchable electronics
Romeo, A., Liu, Q., Suo, Z., & Lacour, S. P. (2013) · Applied Physics Letters · doi:10.1063/1.4799653 · Cited by 117
Temporal properties of visual perception on electrical stimulation of the retina
Pérez Fornos, A., Sommerhalder, J., da Cruz, L., Sahel, J. A., Mohand-Said, S., Hafezi, F., & Pelizzone, M. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-9344 · Cited by 113
Light damage to the retina: an historical approach
Norren, D. V., & Vos, J. J. (2015) · Eye · doi:10.1038/eye.2015.218 · Cited by 111
Resolution of the epiretinal prosthesis is not limited by electrode size
Behrend, M. R., Ahuja, A. K., Humayun, M. S., Chow, R. H., & Weiland, J. D. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2140132 · Cited by 102
Area dependent efficiency of organic solar cells
Gupta, D., Bag, M., & Narayan, K. S. (2008) · Applied Physics Letters · doi:10.1063/1.2998540 · Cited by 97
Antognazza, M. R., Paolo, M. D., Ghezzi, D., Mete, M., Marco, S. D., Maya‐Vetencourt, J. F., Maccarone, R., Desii, A., Fonzo, F. D., Bramini, M., et al. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600318 · Cited by 89
Self-citationRetinal prostheses: progress toward the next generation implants
Ghezzi, D. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00290 · Cited by 83
Self-citationPosterior Eye Shape Measurement With Retinal OCT Compared to MRI
Kuo, A. N., Verkicharla, P. K., McNabb, R. P., Cheung, C. Y.-L., Hilal, S., Farsiu, S., Chen, C., Wong, T. Y., Ikram, M. K., Cheng, C., et al. (2016) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.15-18886 · Cited by 72
Fornos, A. P., Sommerhalder, J., Rappaz, B., Safran, A. B., & Pelizzone, M. (2005) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.04-1173 · Cited by 69
Ten-Year Follow-up of a Blind Patient Chronically Implanted with Epiretinal Prosthesis Argus I
Lan, Y., Falabella, P., Christopher, P., Wuyyuru, V., Dorn, J. D., Schor, P., Greenberg, R. J., Weiland, J. D., & Humayun, M. S. (2015) · Ophthalmology · doi:10.1016/j.ophtha.2015.08.008 · Cited by 67
Intravitreal Injection of Normal Saline Induces Retinal Degeneration in the C57BL/6J Mouse
Hombrebueno, J. R., Luo, C., Guo, L., Chen, M., & Xu, H. (2014) · Translational Vision Science & Technology · doi:10.1167/tvst.3.2.3 · Cited by 66
SiC protective coating for photovoltaic retinal prosthesis
Lei, X., Kane, S. R., Cogan, S. F., Lorach, H., Galambos, L., Huie, P., Mathieson, K., Kamins, T. I., Harris, J. S., & Palanker, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046016 · Cited by 64
Photovoltaic Pixels for Neural Stimulation: Circuit Models and Performance
Boinagrov, D., Lei, X., Goetz, G., Kamins, T. I., Mathieson, K., Galambos, L., Harris, J. S., & Palanker, D. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2376528 · Cited by 60
Diamond Devices for High Acuity Prosthetic Vision
Ahnood, A., Hamish Meffin, A., Garrett, D. J., Fox, K. E., Ganesan, K., Stacey, A. D., Apollo, N. V., Wong, Y. T., Lichter, S. G., Kentler, W. G., et al. (2016) · Advanced Biosystems · doi:10.1002/adbi.201600003 · Cited by 59
Active confocal imaging for visual prostheses
Jung, J., Aloni, D., Yitzhak Yitzhaky, B., & Eli Peli, A. (2014) · Vision Research · doi:10.1016/j.visres.2014.10.023 · Cited by 51
Development of very large electrode arrays for epiretinal stimulation (VLARS)
Waschkowski, F., Hesse, S., Rieck, A. C., Lohmann, T., Brockmann, C., Laube, T., Bornfeld, N., Thumann, G., Walter, P., Mokwa, W., et al. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-11 · Cited by 43
Toward a wide-field retinal prosthesis
Ameri, H., Ratanapakorn, T., Ufer, S., Eckhardt, H., Humayun, M. S., & Weiland, J. D. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/035002 · Cited by 40
Retinal safety of near infrared radiation in photovoltaic restoration of sight.
Lorach, H., Wang, J., Lee, D. Y., Dalal, R., Huie, P., & Palanker, D. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.000013 · Cited by 33
Implantation of modular photovoltaic subretinal prosthesis
Lee, D. Y., Lorach, H., Huie, P., & Palanker, D. (2016) · Ophthalmic Surgery, Lasers and Imaging Retina · doi:10.3928/23258160-20160126-11 · Cited by 30
Chapter 1—restoring vision to the blind: the new age of implanted visual prostheses
(2014) · Translational Vision Science & Technology · doi:10.1167/tvst.3.7.3 · Cited by 21
Tumbleston, J. R., Ko, D.-H., Samulski, E. T., & López, R. (2010) · Physical Review B · doi:10.1103/physrevb.82.205325 · Cited by 18
Cited by
Sorted by citations
Organic Bioelectronics: From Functional Materials to Next‐Generation Devices and Power Sources
Ohayon, D., & Inal, S. (2020) · Advanced Materials · doi:10.1002/adma.202001439 · Cited by 178
Lee, S., Shi, Q., & Lee, C. (2019) · APL Materials · doi:10.1063/1.5063498 · Cited by 164
Recent Progress in Wireless Sensors for Wearable Electronics
Park, Y., Lee, S.-I., & Park, J. (2019) · Sensors · doi:10.3390/s19204353 · Cited by 164
Ejneby, M. S., Jakešová, M., Ferrero, J. J., Migliaccio, L., Sahalianov, I. Y., Zhao, Z., Magnus Berggren, A., Khodagholy, D., Đerek, V., Gelinas, J. N., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00817-7 · Cited by 156
Wang, J., He, T., & Lee, C. (2019) · Nano Energy · doi:10.1016/j.nanoen.2019.104039 · Cited by 129
Metadata
- Authors
- Ferlauto, L., Airaghi Leccardi, M. J. I., Chenais, N. A. L., Gilliéron, S. C. A., Vagni, P., Bevilacqua, M., Wolfensberger, T. J., Sivula, K., & Ghezzi, D.
- Affiliations
- École Polytechnique Fédérale de Lausanne (CH)
- Hôpital Ophtalmique Jules-Gonin (CH)
- Corresponding author
- Ghezzi, Diego
- ORCID
- Venue
- Nature Communications
- Published
- 2018-03-08
- Volume
- 9
- Issue
- 1
- Pages
- 992-992
- ISSN
- 2041-1723 (ISSN-L)
- PMC
- PMC5843635
- OpenAlex
- W2791025612
- Cited by
- 183
- References
- 48
- Citations by year
- 2026: 13 · 2025: 22 · 2024: 24 · 2023: 25 · 2022: 26 · 2021: 25 · 2020: 24 · 2019: 20 · 2018: 3
- FWCI
- 8.20
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Nature Communications (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, other-oa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- SERVAL (Université de Lausanne) (publishedVersion, cc-by)
- IRIS (submittedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Funders
- Velux Stiftung
- European Commission (701632)
- École Polytechnique Fédérale de Lausanne
- Fondation Pierre Mercier
- Fondation Pierre Mercier pour la Science
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Physical Sciences › Engineering › Electrical and Electronic Engineering › CCD and CMOS Imaging Sensors
- Keywords
- epiretinal prosthesis, blindness, accelerated aging, visual field restoration, visual acuity
- MeSH terms
- Humans, Prosthesis Design, Retina, Visual Acuity, Prosthesis Implantation, Visual Prosthesis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review