NIR-II nanoprobes in-vivo assembly to improve image-guided surgery for metastatic ovarian cancer
Open accessThe DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
Local recurrence is a common cause of treatment failure for patients with solid tumors. Tumor-specific intraoperative fluorescence imaging may improve staging and debulking efforts in cytoreductive surgery and, thereby improve prognosis. Here, we report in vivo assembly of the second near-infrared window (NIR-II) emitting downconversion nanoparticles (DCNPs) modified with DNA and targeting peptides to improve the image-guided surgery for metastatic ovarian cancer. The NIR-II imaging quality with DCNPs is superior to that of clinically approved ICG with good photostability and deep tissue penetration (8 mm). Stable tumor retention period experienced 6 h by in vivo assembly of nanoprobes can be used for precise tumor resection. Superior tumor-to-normal tissue ratio is successfully achieved to facilitate the abdominal ovarian metastases surgical delineation. Metastases with ≤1 mm can be completely excised under NIR-II bioimaging guidance. This novel technology provides a general new basis for the future design of nanomaterials for medical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Wang, H., Agarwal, P., Zhao, S., Yu, J., Lu, X., & He, X. (2015) · Nature Communications · doi:10.1038/ncomms10081 · Cited by 113
RetractedNanocarriers as an emerging platform for cancer therapy
Peer, D., Karp, J. M., Hong, S., Farokhzad, O. C., Margalit, R., & Langer, R. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.387 · Cited by 8,710
In vivo near-infrared fluorescence imaging
Frangioni, J. V. (2003) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2003.08.007 · Cited by 2,653
Quantum-dot-tagged microbeads for multiplexed optical coding of biomolecules
Han, M., Gao, X., Su, J. Z., & Nie, S. (2001) · Nature Biotechnology · doi:10.1038/90228 · Cited by 2,631
Imaging in the era of molecular oncology
Weissleder, R., & Pittet, M. J. (2008) · Nature · doi:10.1038/nature06917 · Cited by 2,364
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
van Dam, G. M., Themelis, G., Crane, L. M. A., Harlaar, N. J., Pleijhuis, R. G., Kelder, W., Sarantopoulos, A., de Jong, J. S., Arts, H. J. G., van der Zee, A. G. J., et al. (2011) · Nature Medicine · doi:10.1038/nm.2472 · Cited by 1,545
Controlling upconversion nanocrystals for emerging applications
Zhou, B., Shi, B., Jin, D., & Liu, X. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.251 · Cited by 1,503
Image-guided cancer surgery using near-infrared fluorescence
Vahrmeijer, A. L., Hutteman, M., van der Vorst, J. R., van de Velde, C. J. H., & Frangioni, J. V. (2013) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2013.123 · Cited by 1,466
Through-skull fluorescence imaging of the brain in a new near-infrared window
Hong, G., Diao, S., Chang, J., Antaris, A. L., Chen, C., Zhang, B., Zhao, S., Atochin, D. N., Huang, P. L., Andreasson, K. I., et al. (2014) · Nature Photonics · doi:10.1038/nphoton.2014.166 · Cited by 1,061
Molecular afterglow imaging with bright, biodegradable polymer nanoparticles
Miao, Q., Xie, C., Zhen, X., Lyu, Y., Duan, H., Liu, X., Jokerst, J. V., & Pu, K. (2017) · Nature Biotechnology · doi:10.1038/nbt.3987 · Cited by 975
Real‐time identification of liver cancers by using indocyanine green fluorescent imaging
Ishizawa, T., Fukushima, N., Shibahara, J., Masuda, K., Tamura, S., Aoki, T., Hasegawa, K., Beck, Y., Fukayama, M., & Kokudo, N. (2009) · Cancer · doi:10.1002/cncr.24291 · Cited by 852
Schaafsma, B. E., Mieog, J. S. D., Hutteman, M., van der Vorst, J. R., Kuppen, P. J. K., Löwik, C. W. G. M., Frangioni, J. V., van de Velde, C. J. H., & Vahrmeijer, A. L. (2011) · Journal of Surgical Oncology · doi:10.1002/jso.21943 · Cited by 816
Self-illuminating quantum dot conjugates for in vivo imaging
So, M.-K., Xu, C., Loening, A. M., Gambhir, S. S., & Rao, J. (2006) · Nature Biotechnology · doi:10.1038/nbt1188 · Cited by 807
Self-citationRare-earth-doped biological composites as in vivo shortwave infrared reporters
Naczynski, D. J., Tan, M. C., Zevon, M., Wall, B., Kohl, J., Kulesa, A., Chen, S., Roth, C. M., Riman, R. E., & Moghe, P. V. (2013) · Nature Communications · doi:10.1038/ncomms3199 · Cited by 759
In Vivo Fluorescence Imaging with Ag2S Quantum Dots in the Second Near‐Infrared Region
Hong, G., Robinson, J. T., Zhang, Y., Diao, S., Antaris, A. L., Wang, Q., & Dai, H. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201206059 · Cited by 744
Next-generation in vivo optical imaging with short-wave infrared quantum dots
Bruns, O. T., Bischof, T. S., Harris, D. K., Franke, D., Shi, Y., Riedemann, L., Bartelt, A., Jaworski, F. B., Carr, J. A., Rowlands, C. J., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0056 · Cited by 686
Li, B., Lu, L., Zhao, M., Lei, Z., & Zhang, F. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201801226 · Cited by 658
Self-citationOlson, E. S., Jiang, T., Aguilera, T. A., Nguyen, Q. T., Ellies, L. G., Scadeng, M., & Tsien, R. Y. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910283107 · Cited by 567
Noninvasive cell-tracking methods
Kircher, M. F., Gambhir, S. S., & Grimm, J. (2011) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2011.141 · Cited by 501
Nguyen, Q. T., Olson, E. S., Aguilera, T. A., Jiang, T., Scadeng, M., Ellies, L. G., & Tsien, R. Y. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910261107 · Cited by 474
Rapid Cancer Detection by Topically Spraying a γ-Glutamyltranspeptidase–Activated Fluorescent Probe
Urano, Y., Sakabe, M., Kosaka, N., Ogawa, M., Mitsunaga, M., Asanuma, D., Kamiya, M., Young, M. R., Nagano, T., Choyke, P. L., et al. (2011) · Science Translational Medicine · doi:10.1126/scitranslmed.3002823 · Cited by 466
New approaches for imaging tumour responses to treatment
Brindle, K. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2289 · Cited by 460
Chen, G., Ohulchanskyy, T. Y., Liu, S., Law, W.-C., Wu, F., Swihart, M. T., Ågren, H., & Prasad, P. N. (2012) · ACS Nano · doi:10.1021/nn2042362 · Cited by 449
DNA assembly of nanoparticle superstructures for controlled biological delivery and elimination
Chou, L. Y. T., Zagorovsky, K., & Chan, W. C. W. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2013.309 · Cited by 428
Qi, J., Sun, C., Zebibula, A., Zhang, H., Kwok, R. T. K., Zhao, X., Xi, W., Lam, J. W. Y., Qian, J., & Tang, B. Z. (2018) · Advanced Materials · doi:10.1002/adma.201706856 · Cited by 418
Flavylium Polymethine Fluorophores for Near‐ and Shortwave Infrared Imaging
Cosco, E. D., Caram, J. R., Bruns, O. T., Franke, D., Day, R. A., Farr, E. P., Bawendi, M. G., & Sletten, E. M. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201706974 · Cited by 415
Intraoperative MRI-guided resection of glioblastoma multiforme: a systematic review
Kubben, P. L., ter Meulen, K. J., Schijns, O. E., ter Laak-Poort, M. P., van Overbeeke, J. J., & Santbrink, H. V. (2011) · The Lancet Oncology · doi:10.1016/s1470-2045(11)70130-9 · Cited by 408
A spatially and temporally restricted mouse model of soft tissue sarcoma
Kirsch, D. G., Dinulescu, D. M., Miller, J. B., Grimm, J., Santiago, P. M., Young, N. P., Nielsen, G. P., Quade, B. J., Chaber, C. J., Schultz, C. P., et al. (2007) · Nature Medicine · doi:10.1038/nm1602 · Cited by 301
Li, L.-L., Wu, P., Hwang, K., & Lu, Y. (2013) · Journal of the American Chemical Society · doi:10.1021/ja310432u · Cited by 280
Wang, R., Zhou, L., Wang, W., Li, X., & Zhang, F. (2017) · Nature Communications · doi:10.1038/ncomms14702 · Cited by 272
Self-citationGhosh, D., Bagley, A. F., Na, Y. J., Birrer, M. J., Bhatia, S. N., & Belcher, A. M. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1400821111 · Cited by 251
Zhang, X., Tian, Y., Zhang, C., Tian, X., Ross, A. W., Moir, R. D., Sun, H., Tanzi, R. E., Moore, A., & Ran, C. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1505420112 · Cited by 225
Vinegoni, C., Botnaru, I., Aikawa, E., Calfon, M. A., Iwamoto, Y., Folco, E. J., Ntziachristos, V., Weissleder, R., Libby, P., & Jaffer, F. A. (2011) · Science Translational Medicine · doi:10.1126/scitranslmed.3001577 · Cited by 215
Molecular Body Imaging: MR Imaging, CT, and US. Part I. Principles
Kircher, M. F., & Willmann, J. K. (2012) · Radiology · doi:10.1148/radiol.12102394 · Cited by 209
Ultrasmall Sub-10 nm Near-Infrared Fluorescent Mesoporous Silica Nanoparticles
Ma, K., Sai, H., & Wiesner, U. (2012) · Journal of the American Chemical Society · doi:10.1021/ja3049783 · Cited by 202
Dang, X., Gu, L., Qi, J., Correa, S., Zhang, G., Belcher, A. M., & Hammond, P. T. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1521175113 · Cited by 189
Chirality Enriched (12,1) and (11,3) Single-Walled Carbon Nanotubes for Biological Imaging
Diao, S., Hong, G., Robinson, J. T., Jiao, L., Antaris, A. L., Wu, J. Z., Choi, C. L., & Dai, H. (2012) · Journal of the American Chemical Society · doi:10.1021/ja307966u · Cited by 187
In vivo assembly of nanoparticle components to improve targeted cancer imaging
Perrault, S. D., & Chan, W. C. W. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1001367107 · Cited by 181
Verbeek, F. P. R., van der Vorst, J. R., Schaafsma, B. E., Swijnenburg, R.-J., Gaarenstroom, K. N., Elzevier, H. W., van de Velde, C. J. H., Frangioni, J. V., & Vahrmeijer, A. L. (2013) · Journal of Urology · doi:10.1016/j.juro.2013.02.3187 · Cited by 176
Imaging of Liver Tumors Using Surface-Enhanced Raman Scattering Nanoparticles
Andreou, C., Neuschmelting, V., Tschaharganeh, D.-F., Huang, C.-H., Oseledchyk, A., Iacono, P., Karabeber, H., Colen, R. R., Mannelli, L., Lowe, S. W., et al. (2016) · ACS Nano · doi:10.1021/acsnano.5b07200 · Cited by 170
Oseledchyk, A., Andreou, C., Wall, M. A., & Kircher, M. F. (2017) · ACS Nano · doi:10.1021/acsnano.6b06796 · Cited by 144
In Vivo Fluorescence Imaging with Ag2S Quantum Dots in the Second Near‐Infrared Region
Hong, G., Robinson, J. T., Zhang, Y., Diao, S., Antaris, A. L., Wang, Q., & Dai, H. (2012) · Angewandte Chemie · doi:10.1002/ange.201206059 · Cited by 128
Early tumor detection afforded by in vivo imaging of near-infrared II fluorescence
Tao, Z., Dang, X., Huang, X., Muzumdar, M. D., Xu, E. S., Bardhan, N. M., Song, H., Qi, R., Yu, Y., Li, T., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.04.046 · Cited by 119
Lumpectomy margins are affected by tumor size and histologic subtype but not by biopsy technique
Chagpar, A. B., Martin, R. C. G., Hagendoorn, L. J., Chao, C., & McMasters, K. M. (2004) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2004.06.020 · Cited by 116
Zhang, X., Chen, J., Zheng, Y., Gao, X., Kang, Y., Liu, J.-C., Cheng, M., Sun, H., & Xu, C. (2009) · Cancer Research · doi:10.1158/0008-5472.can-08-4721 · Cited by 98
Self-citationWiner, J. H., Choi, H. S., Gibbs‐Strauss, S. L., Ashitate, Y., Colson, Y. L., & Frangioni, J. V. (2009) · Annals of Surgical Oncology · doi:10.1245/s10434-009-0868-8 · Cited by 80
Yao, C., Wang, P., Zhou, L., Wang, R., Li, X., Zhao, D., & Zhang, F. (2014) · Analytical Chemistry · doi:10.1021/ac5023259 · Cited by 80
Self-citationStoring single photons emitted by a quantum memory on a highly excited Rydberg state
Distante, E., Farrera, P., Padrón-Brito, A., Paredes-Barato, D., Heinze, G., & de Riedmatten, H. (2017) · Nature Communications · doi:10.1038/ncomms14072 · Cited by 71
Zeng, C., Shang, W., Wang, K., Chi, C., Jia, X., Fang, C., Yang, D., Ye, J., Fang, C., & Tian, J. (2016) · Scientific Reports · doi:10.1038/srep21959 · Cited by 70
Rizzo, M., Iyengar, R., Gabram, S. G. A., Park, J. M., Birdsong, G. G., Chandler, K. L., & Mošunjac, M. (2009) · Annals of Surgical Oncology · doi:10.1245/s10434-009-0643-x · Cited by 68
Surveillance nanotechnology for multi-organ cancer metastases
Kantamneni, H., Zevon, M., Donzanti, M. J., Zhao, X., Yang, S., Barkund, S. R., McCabe, L. H., Banach-Petrosky, W. A., Higgins, L. M., Ganesan, S., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0167-9 · Cited by 67
Flavylium Polymethine Fluorophores for Near‐ and Shortwave Infrared Imaging
Cosco, E. D., Caram, J. R., Bruns, O. T., Franke, D., Day, R. A., Farr, E. P., Bawendi, M. G., & Sletten, E. M. (2017) · Angewandte Chemie · doi:10.1002/ange.201706974 · Cited by 65
Cheung, S., & O’Shea, D. F. (2017) · Nature Communications · doi:10.1038/s41467-017-02060-8 · Cited by 53
Resection margin status in lumpectomy specimens of infiltrating lobular carcinoma
Mai, K. T., Yazdi, H. M., & Isotalo, P. A. (2000) · Breast Cancer Research and Treatment · doi:10.1023/a:1006359308505 · Cited by 32
Damian, C.-D., Rednic, N., Munteanu, D., & Cazacu, M. (2014) · Medical Ultrasonography · doi:10.11152/mu.201.3.2066.162.cdd1nr2 · Cited by 12
Cited by
Near-infrared luminescence high-contrast in vivo biomedical imaging
Chen, Y., Wang, S., & Zhang, F. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-022-00002-8 · Cited by 566
Self-citationIn vivo NIR-II fluorescence imaging for biology and medicine
Wang, F., Zhong, Y., Bruns, O., Liang, Y., & Dai, H. (2024) · Nature Photonics · doi:10.1038/s41566-024-01391-5 · Cited by 564
“Surgical removal of tumours (for example, glioblastoma 18 , pancreatic tumour 106 , colo-rectal tumour 20 , ovarian tumour 107 and breast tumour 94 ) navigated by NIR-II imaging holds great promise.”
Current advance of nanotechnology in diagnosis and treatment for malignant tumors
Wang, B., Hu, S., Teng, Y., Chen, J., Wang, H., Xu, Y., Wang, K., Xu, J., Cheng, Y., & Gao, X. (2024) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-024-01889-y · Cited by 558
Liu, Y., Li, Y., Koo, S., Sun, Y., Liu, Y., Liu, X., Pan, Y., Zhang, Z., Du, M., Lu, S., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00553 · Cited by 537
Atomic‐Precision Gold Clusters for NIR‐II Imaging
Liu, H., Hong, G., Luo, Z., Chen, J., Chang, J., Gong, M., He, H., Yang, J., Yuan, X., Li, L., et al. (2019) · Advanced Materials · doi:10.1002/adma.201901015 · Cited by 440
Metadata
- Authors
- Wang, P., Fan, Y., Lu, L., Liu, L., Fan, L., Zhao, M., Xie, Y., Xu, C., & Zhang, F.
- Venue
- Nature Communications
- Published
- 2018-07-24
- Volume
- 9
- Issue
- 1
- Pages
- 2898-2898
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2883358359
- Cited by
- 451
- References
- 56
- FWCI
- 21.24
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.