Microfluidic cell culture systems for drug research
The DOI matches its Crossref record; 151 of the 151 references it cites were found in a registry or an index.
Abstract
In pharmaceutical research, an adequate cell-based assay scheme to efficiently screen and to validate potential drug candidates in the initial stage of drug discovery is crucial. In order to better predict the clinical response to drug compounds, a cell culture model that is faithful to in vivo behavior is required. With the recent advances in microfluidic technology, the utilization of a microfluidic-based cell culture has several advantages, making it a promising alternative to the conventional cell culture methods. This review starts with a comprehensive discussion on the general process for drug discovery and development, the role of cell culture in drug research, and the characteristics of the cell culture formats commonly used in current microfluidic-based, cell-culture practices. Due to the significant differences in several physical phenomena between microscale and macroscale devices, microfluidic technology provides unique functionality, which is not previously possible by using traditional techniques. In a subsequent section, the niches for using microfluidic-based cell culture systems for drug research are discussed. Moreover, some critical issues such as cell immobilization, medium pumping or gradient generation in microfluidic-based, cell-culture systems are also reviewed. Finally, some practical applications of microfluidic-based, cell-culture systems in drug research particularly those pertaining to drug toxicity testing and those with a high-throughput capability are highlighted.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Taking Cell-Matrix Adhesions to the Third Dimension
Cukierman, E., Pankov, R., Stevens, D. R., & Yamada, K. M. (2001) · Science · doi:10.1126/science.1064829 · Cited by 3,027
The third dimension bridges the gap between cell culture and live tissue
Pampaloni, F., Reynaud, E. G., & Stelzer, E. H. K. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2236 · Cited by 2,817
THE CHEMOTACTIC EFFECT OF MIXTURES OF ANTIBODY AND ANTIGEN ON POLYMORPHONUCLEAR LEUCOCYTES
Boyden, S. (1962) · The Journal of Experimental Medicine · doi:10.1084/jem.115.3.453 · Cited by 2,733
Benya, P. D., & Shaffer, J. D. (1982) · Cell · doi:10.1016/0092-8674(82)90027-7 · Cited by 2,284
High Interstitial Fluid Pressure - an Obstacle in Cancer Therapy
Heldin, C.-H., Rubin, K., Pietras, K., & Östman, A. (2004) · Nature reviews. Cancer · doi:10.1038/nrc1456 · Cited by 2,222
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
Cells lying on a bed of microneedles: An approach to isolate mechanical force
Tan, J. L., Tien, J., Pirone, D. M., Gray, D. S., Bhadriraju, K., & Chen, C. S. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0235407100 · Cited by 1,962
Laser, D. J., & Santiago, J. G. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/6/r01 · Cited by 1,848
Lab-on-a-chip: microfluidics in drug discovery
Dittrich, P. S., & Manz, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1985 · Cited by 1,844
Abbott, A. (2003) · Nature · doi:10.1038/424870a · Cited by 1,234
Microscale culture of human liver cells for drug development
Khetani, S. R., & Bhatia, S. N. (2008) · Nature Biotechnology · doi:10.1038/nbt1361 · Cited by 1,219
Becker, H. (2002) · Talanta · doi:10.1016/s0039-9140(01)00594-x · Cited by 1,187
Surface engineering approaches to micropattern surfaces for cell-based assays
Falconnet, D., Csucs, G., Michelle Grandin, H., & Textor, M. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.12.024 · Cited by 944
Microengineered hydrogels for tissue engineering
Khademhosseini, A., & Langer, R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.07.021 · Cited by 830
Efimenko, K., Wallace, W. E., & Genzer, J. (2002) · Journal of Colloid and Interface Science · doi:10.1006/jcis.2002.8594 · Cited by 757
Inkjet printing for high-throughput cell patterning
Roth, E. A., Xu, T., Das, M., Gregory, C., Hickman, J. J., & Boland, T. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.052 · Cited by 714
Anderson, J. R., Chiu, D. T., Jackman, R. J., Cherniavskaya, O., McDonald, J. C., Wu, H., Whitesides, S. H., & Whitesides, G. M. (2000) · Analytical Chemistry · doi:10.1021/ac9912294 · Cited by 698
Screening of Protein Crystallization Conditions on a Microfluidic Chip Using Nanoliter-Size Droplets
Zheng, B., Roach, L. S., & Ismagilov, R. F. (2003) · Journal of the American Chemical Society · doi:10.1021/ja037166v · Cited by 697
Webb, K., Hlady, V., & Tresco, P. A. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19980905)41:3<422::aid-jbm12>3.0.co;2-k · Cited by 689
Biomolecular gradients in cell culture systems
Keenan, T. M., & Folch, A. (2008) · Lab Chip · doi:10.1039/b711887b · Cited by 596
Human neural stem cell growth and differentiation in a gradient-generating microfluidic device
Chung, B. G., Flanagan, L. A., Rhee, S. W., Schwartz, P. H., Lee, A. P., Monuki, E. S., & Jeon, N. L. (2005) · Lab on a Chip · doi:10.1039/b417651k · Cited by 556
Probing the role of multicellular organization in three-dimensional microenvironments
Albrecht, D. R., Underhill, G. H., Wassermann, T. B., Sah, R. L., & Bhatia, S. N. (2006) · Nature Methods · doi:10.1038/nmeth873 · Cited by 552
Patterning cells and their environments using multiple laminar fluid flows in capillary networks
Takayama, S., McDonald, J. C., Ostuni, E., Liang, M. N., Kenis, P. J. A., Ismagilov, R. F., & Whitesides, G. M. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.10.5545 · Cited by 528
Continuous perfusion microfluidic cell culture array for high‐throughput cell‐based assays
Hung, P. J., Lee, P. J., Sabounchi, P., Lin, R., & Lee, L. P. (2005) · Biotechnology and Bioengineering · doi:10.1002/bit.20289 · Cited by 522
Hillborg, H., Ankner, J. F., Gedde, U. W., Smith, G. D., Yasuda, H. K., & Wikström, K. (2000) · Polymer · doi:10.1016/s0032-3861(00)00039-2 · Cited by 511
Heit, B., Tavener, S., Raharjo, E., & Kubes, P. (2002) · The Journal of Cell Biology · doi:10.1083/jcb.200202114 · Cited by 485
Lab-on-a-chip for drug development
Weigl, B. H., Bardell, R. L., & Cabrera, C. R. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00223-5 · Cited by 481
Integration of Cell Culture and Microfabrication Technology
Park, T. H., & Shuler, M. L. (2003) · Biotechnology Progress · doi:10.1021/bp020143k · Cited by 473
Sung, J. H., & Shuler, M. L. (2009) · Lab on a Chip · doi:10.1039/b901377f · Cited by 431
Marker-specific sorting of rare cells using dielectrophoresis
Hu, X., Bessette, P. H., Qian, J., Meinhart, C. D., Daugherty, P. S., & Soh, H. T. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507719102 · Cited by 428
Raballo, R., Rhee, J., Lyn-Cook, R., Leckman, J. F., Schwartz, M. L., & Vaccarino, F. M. (2000) · The Journal of Neuroscience · doi:10.1523/jneurosci.20-13-05012.2000 · Cited by 420
A microfluidic 3D hepatocyte chip for drug toxicity testing
Toh, Y.-C., Lim, T. C., Tai, D., Xiao, G., van Noort, D., & Yu, H. (2009) · Lab on a Chip · doi:10.1039/b900912d · Cited by 419
Effect of Adsorbed Proteins on the Wettability of Hydrophilic and Hydrophobic Solids
VROMAN, L. (1962) · Nature · doi:10.1038/196476a0 · Cited by 403
エレクトロウェッティングディスプレイの油脱ぬれパターンの観測と光学的意味 | 文献情報 | J-GLOBAL 科学技術総合リンクセンター
Bo, S., & Jason, H. (2008) · Journal of Micromechanics and Microengineering · Cited by 395
Microenvironment design considerations for cellular scale studies
Walker, G. M., Zeringue, H. C., & Beebe, D. J. (2004) · Lab on a Chip · doi:10.1039/b311214d · Cited by 388
Compatibility of Mammalian Cells on Surfaces of Poly(dimethylsiloxane)
Lee, J. N., Jiang, X., Ryan, D., & Whitesides, G. M. (2004) · Langmuir · doi:10.1021/la048562+ · Cited by 379
van Wachem, P. B., Hogt, A. H., Beugeling, T., Feijen, J., Bantjes, A., Detmers, J. P., & van Aken, W. G. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90001-9 · Cited by 372
Engineering cellular microenvironments to improve cell-based drug testing
Bhadriraju, K., & Chen, C. S. (2002) · Drug Discovery Today · doi:10.1016/s1359-6446(02)02273-0 · Cited by 355
Cell Culture Models in Microfluidic Systems
Meyvantsson, I., & Beebe, D. J. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.113042 · Cited by 345
Vickerman, V., Blundo, J., Chung, S., & Kamm, R. (2008) · Lab on a Chip · doi:10.1039/b802395f · Cited by 340
Kang, L., Chung, B. G., Langer, R., & Khademhosseini, A. (2008) · Drug Discovery Today · doi:10.1016/j.drudis.2007.10.003 · Cited by 325
Programmed assembly of 3-dimensional microtissues with defined cellular connectivity
Gartner, Z. J., & Bertozzi, C. R. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0900717106 · Cited by 315
Three-dimensional in vitro tissue culture models of breast cancer — a review
Kim, J. B., Stein, R., & O'Hare, M. J. (2004) · Breast Cancer Research and Treatment · doi:10.1023/b:brea.0000025418.88785.2b · Cited by 313
Sivaraman, A., Leach, J., Townsend, S., Iida, T., Hogan, B., Stolz, D., Fry, R., Samson, L., Tannenbaum, S., & Griffith, L. (2005) · Current Drug Metabolism · doi:10.2174/138920005774832632 · Cited by 310
Sun, T., Jackson, S., Haycock, J. W., & MacNeil, S. (2006) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2005.12.021 · Cited by 308
Development of a Microscale Cell Culture Analog To Probe Naphthalene Toxicity
Viravaidya, K., Sin, A., & Shuler, M. L. (2008) · Biotechnology Progress · doi:10.1021/bp0341996 · Cited by 305
Kimura, H., Yamamoto, T., Sakai, H., Sakai, Y., & Fujii, T. (2008) · Lab on a Chip · doi:10.1039/b717091b · Cited by 290
Comparison of Chondrogensis in Static and Perfused Bioreactor Culture
Pazzano, D., Mercier, K. A., Moran, J. M., Fong, S. S., DiBiasio, D. D., Rulfs, J. X., Kohles, S. S., & Bonassar, L. J. (2000) · Biotechnology Progress · doi:10.1021/bp000082v · Cited by 266
Liver-Specific Functional Studies in a Microfluidic Array of Primary Mammalian Hepatocytes
Kane, B. J., Zinner, M. J., Yarmush, M. L., & Toner, M. (2006) · Analytical Chemistry · doi:10.1021/ac051856v · Cited by 264
Photo- and electropatterning of hydrogel-encapsulated living cell arrays
Albrecht, D. R., Tsang, V. L., Sah, R. L., & Bhatia, S. N. (2005) · Lab on a Chip · doi:10.1039/b406953f · Cited by 260
Modelling tissues in 3D: the next future of pharmaco-toxicology and food research?
Mazzoleni, G., Di Lorenzo, D., & Steimberg, N. (2009) · Genes & Nutrition · doi:10.1007/s12263-008-0107-0 · Cited by 253
Cell-based high content screening using an integrated microfluidic device
Ye, N., Qin, J., Shi, W., Liu, X., & Lin, B. (2007) · Lab on a Chip · doi:10.1039/b711513j · Cited by 246
Heo, Y. S., Cabrera, L. M., Song, J. W., Futai, N., Tung, Y.-C., Smith, G. D., & Takayama, S. (2007) · Analytical Chemistry · doi:10.1021/ac061990v · Cited by 245
Characterization of a membrane-based gradient generator for use in cell-signaling studies
Abhyankar, V. V., Lokuta, M. A., Huttenlocher, A., & Beebe, D. J. (2006) · Lab on a Chip · doi:10.1039/b514133h · Cited by 241
Microfluidic PDMS (Polydimethylsiloxane) Bioreactor for Large-Scale Culture of Hepatocytes
Leclerc, E., Sakai, Y., & Fujii, T. (2004) · Biotechnology Progress · doi:10.1021/bp0300568 · Cited by 234
Universal Microfluidic Gradient Generator
Irimia, D., Geba, D. A., & Toner, M. (2006) · Analytical Chemistry · doi:10.1021/ac0518710 · Cited by 233
Generation of dynamic temporal and spatial concentration gradients using microfluidic devices
Lin, F., Saadi, W., Rhee, S. W., Wang, S.-J., Mittal, S., & Jeon, N. L. (2004) · Lab on a Chip · doi:10.1039/b313600k · Cited by 222
Design and test of a high-performance piezoelectric micropump for drug delivery
Junwu, K., Zhigang, Y., Taijiang, P., Guangming, C., & Boda, W. (2005) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2004.12.002 · Cited by 217
Modulation of functional activities in cultured rat hepatocytes
Guguen-Guillouzo, C., & Guillouzo, A. (1983) · Molecular and Cellular Biochemistry · doi:10.1007/bf00225245 · Cited by 217
Perfusion Increases Cell Content and Matrix Synthesis in Chondrocyte Three-Dimensional Cultures
Davisson, T., Sah, R. L., & Ratcliffe, A. (2002) · Tissue Engineering · doi:10.1089/10763270260424169 · Cited by 213
T cell chemotaxis in a simple microfluidic device
Lin, F., & Butcher, E. C. (2006) · Lab Chip · doi:10.1039/b607071j · Cited by 211
Endothelial cell polarization and chemotaxis in a microfluidic device
Shamloo, A., Ma, N., Poo, M.-M., Sohn, L. L., & Heilshorn, S. C. (2008) · Lab on a Chip · doi:10.1039/b719788h · Cited by 209
Paguirigan, A. L., & Beebe, D. J. (2008) · BioEssays · doi:10.1002/bies.20804 · Cited by 208
A parallel-gradient microfluidic chamber for quantitative analysis of breast cancer cell chemotaxis
Saadi, W., Wang, S.-J., Lin, F., & Jeon, N. L. (2006) · Biomedical Microdevices · doi:10.1007/s10544-006-7706-6 · Cited by 204
Peterson, S. L., McDonald, A., Gourley, P. L., & Sasaki, D. Y. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30166 · Cited by 195
Saadi, W., Rhee, S. W., Lin, F., Vahidi, B., Chung, B. G., & Jeon, N. L. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9051-9 · Cited by 194
Serum protein adsorption and platelet adhesion on pluronic™-adsorbed polysulfone membranes
Higuchi, A., Sugiyama, K., Yoon, B. O., Sakurai, M., Hara, M., Sumita, M., Sugawara, S.-I., & Shirai, T. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00186-8 · Cited by 193
Embryonic stem cells as a source of models for drug discovery
Pouton, C. W., & Haynes, J. M. (2007) · Nature Reviews Drug Discovery · doi:10.1038/nrd2194 · Cited by 186
Prestwich, G. D. (2008) · Accounts of Chemical Research · doi:10.1021/ar7000827 · Cited by 177
A microfluidic platform for 3-dimensional cell culture and cell-based assays
Kim, M. S., Yeon, J. H., & Park, J.-K. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9016-4 · Cited by 166
Freshney, R. I. (1986) · Cited by 165
Analyzing Chemotaxis Using the Dunn Direct-Viewing Chamber
Zicha, D., Dunn, G., & Jones, G. E. (2003) · Humana Press eBooks · doi:10.1385/0-89603-441-0:449 · Cited by 148
Morin, O., & Normand, C. (1986) · Journal of Cellular Physiology · doi:10.1002/jcp.1041290115 · Cited by 142
Park, J. H., & Bae, Y. H. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00306-4 · Cited by 141
Human embryonic stem cell technologies and drug discovery
Jensen, J., Hyllner, J., & Björquist, P. (2009) · Journal of Cellular Physiology · doi:10.1002/jcp.21732 · Cited by 137
Microfluidic Gradient-Generating Device for Pharmacological Profiling
Pihl, J., Sinclair, J., Sahlin, E., Karlsson, M., Petterson, F., Olofsson, J., & Orwar, O. (2005) · Analytical Chemistry · doi:10.1021/ac050218+ · Cited by 135
Suh, H., Jeong, B., Rathi, R. C., & Kim, S. W. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199811)42:2<165::aid-jbm1>3.0.co;2-n · Cited by 134
Fabrication of a modular tissue construct in a microfluidic chip
Bruzewicz, D. A., McGuigan, A. P., & Whitesides, G. M. (2008) · Lab on a Chip · doi:10.1039/b719806j · Cited by 131
Membrane-Based PDMS Microbioreactor for Perfused 3D Primary Rat Hepatocyte Cultures
Ostrovidov, S., Jiang, J., Sakai, Y., & Fujii, T. (2004) · Biomedical Microdevices · doi:10.1023/b:bmmd.0000048560.96140.ca · Cited by 127
Torisawa, Y.-S., Shiku, H., Yasukawa, T., Nishizawa, M., & Matsue, T. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.05.028 · Cited by 124
Pneumatically driven peristaltic micropumps utilizing serpentine-shape channels
Wang, C.-H., & Lee, G. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/2/019 · Cited by 122
Self-citationA novel multishear microdevice for studying cell mechanics
Chau, L. T., Doran, M. R., & Cooper-White, J. J. (2009) · Lab on a Chip · doi:10.1039/b823180j · Cited by 122
Trends in the development of microfluidic cell biochips for in vitro hepatotoxicity
Baudoin, R., Corlu, A., Griscom, L., Legallais, C., & Leclerc, É. (2006) · Toxicology in Vitro · doi:10.1016/j.tiv.2006.11.004 · Cited by 119
Boxshall, K., Wu, M., Cui, Z., Cui, Z., Watts, J. F., & Baker, M. (2006) · Surface and Interface Analysis · doi:10.1002/sia.2274 · Cited by 117
Self-citationRecent Advances in Cell Micropatterning Techniques for Bioanalytical and Biomedical Sciences
Nakanishi, J., Takarada, T., Yamaguchi, K., & Maeda, M. (2008) · Analytical Sciences · doi:10.2116/analsci.24.67 · Cited by 116
Zhu, X. A., Chu, L. Y., Chueh, B.-H., Shen, M., Hazarika, B., Phadke, N., & Takayama, S. (2004) · The Analyst · doi:10.1039/b407623k · Cited by 113
Microfluidic technologies in drug discovery
Pihl, J., Karlsson, M., & Chiu, D. T. (2005) · Drug Discovery Today · doi:10.1016/s1359-6446(05)03571-3 · Cited by 111
Wu, M., Urban, J. P. G., Cui, Z., & Cui, Z. F. (2006) · Biomedical Microdevices · doi:10.1007/s10544-006-9597-y · Cited by 107
Self-citationProtein adsorption and macrophage activation on polydimethylsiloxane and silicone rubber
Anderson, J. M., Ziats, N. P., Azeez, A., Brunstedt, M. R., Stack, S., & Bonfield, T. L. (1996) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856295x00670 · Cited by 106
Fabrication of transferable micropatterned-co-cultured cell sheets with microcontact printing
Elloumi-Hannachi, I., Itoga, K., Kumashiro, Y., Kobayashi, J., Yamato, M., & Okano, T. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.06.033 · Cited by 103
Microscale multilayer cocultures for biomimetic blood vessels
Tan, W., & Desai, T. A. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30182 · Cited by 103
Polymer microchips bonded by O2-plasma activation
Wu, Z., Xanthopoulos, N., Reymond, F., et al. (2002) · Electrophoresis · doi:10.1002/1522-2683(200203)23:5<740::aid-elps740>3.0.co;2-7 · Cited by 102
Ma, B., Zhang, G., Qin, J., & Lin, B. (2008) · Lab on a Chip · doi:10.1039/b809117j · Cited by 100
Effect of Extracellular pH on Matrix Synthesis by Chondrocytes in 3D Agarose Gel
Wu, M., Urban, J. P. G., Cui, Z. F., Cui, Z., & Xu, X. (2007) · Biotechnology Progress · doi:10.1021/bp060024v · Cited by 100
Self-citationPolymer microchips bonded by O2-plasma activation
Wu, Z., Xanthopoulos, N., Reymond, F., Rossier, J. S., & Girault, H. H. (2002) · Electrophoresis · Cited by 100
Rat bone marrow cell response to titanium and titanium alloy with different surface roughness
Rosa, A. L., & Beloti, M. M. (2003) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2003.140106.x · Cited by 99
Gentle cell trapping and release on a microfluidic chip by in situ alginate hydrogel formation
Braschler, T. M., Johann, R. M., Heule, M., Metref, L., & Renaud, P. (2005) · Lab on a Chip · doi:10.1039/b417604a · Cited by 97
NanoLiterBioReactor: Long-Term Mammalian Cell Culture at Nanofabricated Scale
Prokop, A., Prokop, Z., Schaffer, D. K., Kozlov, E., Wikswo, J. P., Cliffel, D. E., & Baudenbacher, F. J. (2004) · Biomedical Microdevices · doi:10.1023/b:bmmd.0000048564.37800.d6 · Cited by 97
Long-term stable electroosmotic pump with ion exchange membranes
Brask, A., Kutter, J. P., & Bruus, H. (2005) · Lab on a Chip · doi:10.1039/b503626g · Cited by 97
A linear dilution microfluidic device for cytotoxicity assays
Walker, G. M., Monteiro‐Riviere, N. A., Rouse, J. G., et al. (2006) · Lab on a Chip · doi:10.1039/b608990a · Cited by 96
Wu, M., Huang, S.-B., Cui, Z., Cui, Z., & Lee, G. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9138-3 · Cited by 95
Self-citationArtificial Tissues in Perfusion Culture
Sittinger, M., Schultz, O., Keyszer, G. M., Minuth, W. W., & Burmester, G. R. (1997) · The International Journal of Artificial Organs · doi:10.1177/039139889702000111 · Cited by 95
Simple poly(dimethylsiloxane) surface modification to control cell adhesion
Wu, M. (2008) · Surface and Interface Analysis · doi:10.1002/sia.2964 · Cited by 94
Self-citationLaser-assisted modification of polystyrene surfaces for cell culture applications
Pfleging, W., Brüns, M., Welle, A., et al. (2007) · Applied Surface Science · doi:10.1016/j.apsusc.2007.05.047 · Cited by 91
Real-Time Microfluidic System for Studying Mammalian Cells in 3D Microenvironments
Lii, J., Hsu, W., Parsa, H., Das, A., Rouse, R., & Sia, S. K. (2008) · Analytical Chemistry · doi:10.1021/ac8000034 · Cited by 91
Thiébaud, P., Lauer, L., Knoll, W., & Offenhäusser, A. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00279-2 · Cited by 91
Ohmori, T., Yang, J.-L., Price, J. O., & Arteaga, C. L. (1998) · Experimental Cell Research · doi:10.1006/excr.1998.4261 · Cited by 88
Manbachi, A., Shrivastava, S., Cioffi, M., Chung, B. G., Moretti, M., Demirci, U., Yliperttula, M. L., & Khademhosseini, A. (2008) · Lab on a Chip · doi:10.1039/b718212k · Cited by 87
Pressure‐driven perfusion culture microchamber array for a parallel drug cytotoxicity assay
Sugiura, S., Edahiro, J., Kikuchi, K., Sumaru, K., & Kanamori, T. (2008) · Biotechnology and Bioengineering · doi:10.1002/bit.21836 · Cited by 86
Ng, C. P., & Pun, S. H. (2007) · Biotechnology and Bioengineering · doi:10.1002/bit.21698 · Cited by 84
A thermopneumatic dispensing micropump
Cooney, C. G., & Towe, B. C. (2004) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2004.05.015 · Cited by 84
Growth of connective tissue progenitor cells on microtextured polydimethylsiloxane surfaces
Mata, Á., Boehm, C., Fleischman, A. J., et al. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10353 · Cited by 83
Generating steep, shear-free gradients of small molecules for cell culture
Kim, T., Pinelis, M., & Maharbiz, M. M. (2008) · Biomedical Microdevices · doi:10.1007/s10544-008-9210-7 · Cited by 82
Glass valveless micropump using electromagnetic actuation
Yamahata, C., Lacharme, F., & Gijs, M. A. M. (2005) · Microelectronic Engineering · doi:10.1016/j.mee.2004.12.018 · Cited by 80
Wu, M., Huang, S.-B., Cui, Z., Cui, Z., & Lee, G. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.07.145 · Cited by 79
Self-citationMicrocavity array (MCA)-based biosensor chip for functional drug screening of 3D tissue models
Kloß, D., Kurz, R., Jahnke, H.-G., Fischer, M., Rothermel, A., Anderegg, U., Simon, J. C., & Robitzki, A. A. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.01.003 · Cited by 77
Houston, K. S. (2002) · Journal of Membrane Science · doi:10.1016/s0376-7388(02)00068-6 · Cited by 73
High-throughput screening of cell responses to biomaterials
Yliperttula, M. L., Chung, B. G., Navaladi, A., Manbachi, A., & Urtti, A. O. (2008) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2008.04.012 · Cited by 69
Ghanem, A., & Shuler, M. L. (2000) · Biotechnology Progress · doi:10.1021/bp9901522 · Cited by 66
Ultrathin poly(ethylene glycol) films for silicon-based microdevices
Sharma, S., Johnson, R. W., & Desai, T. A. (2003) · Applied Surface Science · doi:10.1016/s0169-4332(02)01220-5 · Cited by 66
Chromatography of Biological Materials on Polyethylene Glycol Treated Controlled-Pore Glass
Hawk, G. L., Cameron, J. A., & Larry, B. (1972) · Preparative Biochemistry · doi:10.1080/00327487208061469 · Cited by 65
A microfluidic system for automatic cell culture
Huang, C., & Lee, G. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/7/008 · Cited by 62
Self-citationAinslie, K. M., Kraning, C. M., & Desai, T. A. (2008) · Lab on a Chip · doi:10.1039/b800604k · Cited by 60
Microfluidic delivery of small molecules into mammalian cells based on hydrodynamic focusing
Wang, F., Wang, H., Wang, J., Wang, H.-Y. A., Rummel, P. L., Garimella, S. V., & Lu, C. (2007) · Biotechnology and Bioengineering · doi:10.1002/bit.21737 · Cited by 60
Effect of temperature onBrettanomyces bruxellensis: metabolic and kinetic aspects
Brandam, C., Castro-Martínez, C., Délia, M.-L., Ramon‐Portugal, F., & Strehaiano, P. (2008) · Canadian Journal of Microbiology · doi:10.1139/w07-126 · Cited by 56
Micro/Nanofluidic Device for Single-Cell-Based Assay
Yun, K.-S., & Yoon, E. (2005) · Biomedical microdevices · doi:10.1007/s10544-005-6169-5 · Cited by 51
Komen, J., Wolbers, F., Franke, H. R., Svahn, H. A., Vermes, I., & van den Berg, A. (2008) · Biomedical Microdevices · doi:10.1007/s10544-008-9184-5 · Cited by 50
A coupled field study on the non-linear dynamic characteristics of an electrostatic micropump
Ng, T. Y., Jiang, T. Y., Li, H., et al. (2003) · Journal of Sound and Vibration · doi:10.1016/s0022-460x(03)00517-0 · Cited by 46
Method of Bottom-Up Directed Assembly of Cell-Laden Microgels
Du, Y., Lo, E., Vidula, M. K., et al. (2008) · Cellular and Molecular Bioengineering · doi:10.1007/s12195-008-0020-z · Cited by 46
A microfluidic gradient maker for toxicity testing of bupivacaine and lidocaine
Tirella, A., Marano, M., Vozzi, F., & Ahluwalia, A. D. (2008) · Toxicology in Vitro · doi:10.1016/j.tiv.2008.09.016 · Cited by 45
Ku, C.-J., Oblak, T. D., & Spence, D. M. (2008) · Analytical Chemistry · doi:10.1021/ac801114j · Cited by 45
Electrochemical lab on a chip for high-throughput analysis of anticancer drugs efficiency
Popovtzer, R., Neufeld, T., Popovtzer, A., Rivkin, I., Margalit, R., Engel, D., Nudelman, A., Rephaeli, A., Rishpon, J., & Shacham‐Diamand, Y. (2008) · Nanomedicine Nanotechnology Biology and Medicine · doi:10.1016/j.nano.2008.03.002 · Cited by 44
Prasad, S., & Quijano, J. E. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.05.005 · Cited by 43
Parallel microfluidic networks for studying cellular response to chemical modulation
Liu, D., Wang, L., Zhong, R., Li, B., Ye, N., Liu, X., & Lin, B. (2007) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2007.06.014 · Cited by 43
Yang, M., Yang, J., Li, C., & Zhao, J. (2002) · Lab on a Chip · doi:10.1039/b201021f · Cited by 38
Zguris, J. C., Itle, L. J., Hayes, D. J., & Pishko, M. V. (2005) · Biomedical Microdevices · doi:10.1007/s10544-005-1589-9 · Cited by 34
Integrating multi-unit electrophysiology and plastic culture dishes for network neuroscience
Morales, R., Riss, M., Wang, L., Gavı́n, R., del Rı́o, J. A., Alcubilla, R., & Claverol-Tinturé, E. (2008) · Lab on a Chip · doi:10.1039/b802165a · Cited by 34
BHK cells behaviour on laser treated polydimethylsiloxane surface
Khorasani, M. T., & Mirzadeh, H. (2004) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2004.01.011 · Cited by 31
Microfluidic Tissue Model for Live Cell Screening
Lee, P. J., Gaige, T. A., Ghorashian, N., & Hung, P. J. (2007) · Biotechnology Progress · doi:10.1021/bp070053l · Cited by 27
Automated live cell screening system based on a 24-well-microplate with integrated micro fluidics
Lob, V., Geisler, T., Brischwein, M., et al. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0260-4 · Cited by 26
Microvalve‐assisted patterning platform for measuring cellular dynamics based on 3D cell culture
Kim, M. S., Lee, W., Kim, Y. C., & Park, J. (2008) · Biotechnology and Bioengineering · doi:10.1002/bit.21962 · Cited by 23
Chong, S. L., Mou, D. G., Ali, A. M., et al. (2008) · Hybridoma · doi:10.1089/hyb.2007.0548 · Cited by 20
Leclerc, É., Miyata, F., Furukawa, K. S., Ushida, T., Sakai, Y., & Fujii, T. (2004) · Materials Science and Engineering C · doi:10.1016/j.msec.2003.12.004 · Cited by 18
Animal cell culture technology
Märkl, H. (1994) · Journal of Biotechnology · doi:10.1016/0168-1656(94)90056-6 · Cited by 18
Drug Discovery and Target Validation
NUTTALL, M. E. (2001) · Cells Tissues Organs · doi:10.1159/000047890 · Cited by 15
Patterning of diverse mammalian cell types in serum free medium with photoablation
Dhir, V., Natarajan, A., Stancescu, M., Chunder, A., Bhargava, N., Das, M., Zhai, L., & Molnar, P. (2009) · Biotechnology Progress · doi:10.1002/btpr.150 · Cited by 12
Biomedical Technologies for In Vitro Screening and Controlled Delivery of Neuroactive Compounds
Frampton, J. P., Shuler, M. L., Shain, W. G., & Hynd, M. R. (2008) · Central Nervous System Agents in Medicinal Chemistry · doi:10.2174/187152408785699613 · Cited by 12
Automation and Microfluidic Assays: In Vitro Models of the Mammalian Microcirculation
Spence, D. M. (2005) · JALA Journal of the Association for Laboratory Automation · doi:10.1016/j.jala.2005.06.006 · Cited by 4
Ianescu-Zanetti, C., & Blatz, A. L. (2007) · The Journal of Immunology · doi:10.4049/jimmunol.178.supp.97.9 · Cited by 1
Research works printed but not linked: 7
- Lee, 2007, JALA Charlottesv Va., 12, 363
- Spence, 2005, JALA, 10, 270
- Torisawa, 2005, Biomaterials, 26, 2165, 10.1016/j.biomaterials.2004.05.028 · DOI · Paper page
- Wu, 2002, Electrophoresis, 23, 782, 10.1002/1522-2683(200203)23:5<782::AID-ELPS782>3.0.CO;2-K · doi:10.1002/1522-2683(200203)23:5<782::aid-elps782>3.0.co;2-k
- Hawk, 1972, Prep. Biochem. Biotechnol., 2, 193
- Huang, 2008, J. Micromech. Microeng., 18, 1
- Zicha, 1997, Methods Mol. Biol., 75, 449
Cited by
Three-dimensional cell culture: the missing link in drug discovery
Breslin, S., & O’Driscoll, L. (2013) · Drug Discovery Today · doi:10.1016/j.drudis.2012.10.003 · Cited by 1,332
Advantages and challenges of microfluidic cell culture in polydimethylsiloxane devices
Halldorsson, S., Lucumi, E., Gómez-Sjöberg, R., & Fleming, R. M. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.029 · Cited by 1,027
Single-Cell Metabolomics: Analytical and Biological Perspectives
Zenobi, R. (2013) · Science · doi:10.1126/science.1243259 · Cited by 661
Co-culture systems and technologies: taking synthetic biology to the next level
Goers, L., Freemont, P., & Polizzi, K. M. (2014) · Journal of The Royal Society Interface · doi:10.1098/rsif.2014.0065 · Cited by 630
Revisiting lab-on-a-chip technology for drug discovery
Neužil, P., Giselbrecht, S., Länge, K., Huang, T. J., & Manz, A. (2012) · Nature Reviews Drug Discovery · doi:10.1038/nrd3799 · Cited by 487
Metadata
- Authors
- Wu, M.-H., Huang, S.-B., & Lee, G.-B.
- Affiliations
- Chang Gung University (TW)
- National Cheng Kung University (TW)
- Corresponding author
- Lee, Gwo-Bin
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 10
- Issue
- 8
- Pages
- 939
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2041612826
- Cited by
- 432
- References
- 151
- Citations by year
- 2026: 5 · 2025: 12 · 2024: 17 · 2023: 27 · 2022: 27 · 2021: 24 · 2020: 29 · 2019: 33 · 2018: 26 · 2017: 35 · 2016: 31 · 2015: 26 · 2014: 33 · 2013: 36 · 2012: 28
- FWCI
- 2.69
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- microfluidic cell culture, drug discovery, cell-based assays, drug screening, cell immobilization, gradient generation, drug toxicity testing, high-throughput screening, in vitro model
- MeSH terms
- Animals, Biological Assay, Cell Physiological Phenomena, Drug Evaluation, Preclinical, Pharmaceutical Preparations, Equipment Design, Humans, Flow Injection Analysis, Cell Culture Techniques, Equipment Failure Analysis, Microfluidic Analytical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.