The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
A nondestructive method for determining the spring constant of cantilevers for scanning force microscopy
Abstract
The spring constant of microfabricated cantilevers used in scanning force microscopy (SFM) can be determined by measuring their resonant frequencies before and after adding small end masses. These masses adhere naturally and can be easily removed before using the cantilever for SFM, making the method nondestructive. The observed variability in spring constant—almost an order of magnitude for a single type of cantilever—necessitates calibration of individual cantilevers in work where precise knowledge of forces is required. Measurements also revealed that the spring constant scales with the cube of the unloaded resonant frequency, providing a simple way to estimate the spring constant for less precise work.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Direct measurement of colloidal forces using an atomic force microscope
Ducker, W. A., Senden, T. J., & Pashley, R. M. (1991) · Nature · doi:10.1038/353239a0 · Cited by 2,075
Israelachvili, J. N., & Adams, G. E. (1978) · Journal of the Chemical Society, Faraday Transactions 1: Physical Chemistry in Condensed Phases · doi:10.1039/f19787400975 · Cited by 1,812
Novel optical approach to atomic force microscopy
Meyer, G., & Amer, N. M. (1988) · Applied Physics Letters · doi:10.1063/1.100061 · Cited by 1,290
Measurement of forces in liquids using a force microscope
Ducker, W. A., Senden, T. J., & Pashley, R. M. (1992) · Langmuir · doi:10.1021/la00043a024 · Cited by 1,080
Harris, C. M., Crede, C. E., & Trent, H. M. (1962) · Physics Today · doi:10.1063/1.3058391 · Cited by 1,023
Microfabrication of cantilever styli for the atomic force microscope
Albrecht, T. R., Akamine, S., Carver, T. E., & Quate, C. F. (1990) · Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films · doi:10.1116/1.576520 · Cited by 747
Scanning force microscopy - With Applications to Electric, Magnetic and Atomic Forces
Sarid, D., Coratger, R., Ajustron, F., & Beauvillain, J. (1991) · Microscopy Microanalysis Microstructures · doi:10.1051/mmm:0199100206064900 · Cited by 563
Atomic Resolution with Atomic Force Microscope
Binnig, G., Gerber, C., Stoll, E., Albrecht, T. R., & Quate, C. F. (1987) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/3/12/006 · Cited by 559
Weisenhorn, A. L., Maivald, P., Butt, H.-J., & Hansma, P. K. (1992) · Physical Review B · doi:10.1103/physrevb.45.11226 · Cited by 485
Self-citation
Cited by
Calibration of atomic-force microscope tips
Hutter, J. L., & Bechhoefer, J. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143970 · Cited by 4,194
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 3,709
Calibration of rectangular atomic force microscope cantilevers
Sader, J. E., Chon, J. W. M., & Mulvaney, P. (1999) · Review of Scientific Instruments · doi:10.1063/1.1150021 · Cited by 2,145
Bhushan, B., & Jung, Y. C. (2011) · Progress in Materials Science · doi:10.1016/j.pmatsci.2010.04.003 · Cited by 1,989
Force-distance curves by atomic force microscopy
Cappella, B., & Dietler, G. (1999) · Surface Science Reports · doi:10.1016/s0167-5729(99)00003-5 · Cited by 1,694
Dienwiebel, M., Verhoeven, G. S., Pradeep, N., Frenken, J. W. M., Heimberg, J. A., & Zandbergen, H. W. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.126101 · Cited by 1,428
Scratching the Surface: Fundamental Investigations of Tribology with Atomic Force Microscopy
Carpick, R. W., & Salmeron, M. (1997) · Chemical Reviews · doi:10.1021/cr960068q · Cited by 1,126
Functional Group Imaging by Chemical Force Microscopy
Frisbie, C. D., Rozsnyai, L. F., Noy, A., Wrighton, M. S., & Lieber, C. M. (1994) · Science · doi:10.1126/science.265.5181.2071 · Cited by 1,009
Method for the calibration of atomic force microscope cantilevers
Sader, J. E., Larson, I., Mulvaney, P., & White, L. R. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145439 · Cited by 1,000
Intermolecular Forces and Energies Between Ligands and Receptors
Moy, V. T., Florin, E.-L., & Gaub, H. E. (1994) · Science · doi:10.1126/science.7939660 · Cited by 875
Tapping mode atomic force microscopy in liquids
Hansma, P. K., Cleveland, J. P., Radmacher, M., Walters, D. A., Hillner, P. E., Bezanilla, M., Fritz, M., Vie, D., Hansma, H. G., Prater, C. B., et al. (1994) · Applied Physics Letters · doi:10.1063/1.111795 · Cited by 875
Self-citationMicromechanical cantilever-based biosensors
Raiteri, R., Grattarola, M., Butt, H.-J., & Skládal, P. (2001) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(01)00856-5 · Cited by 734
Calibration of frictional forces in atomic force microscopy
Ogletree, D. F., Carpick, R. W., & Salmeron, M. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147411 · Cited by 604
Bacterial adhesion to glass and metal-oxide surfaces
Li, B., & Logan, B. E. (2004) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2004.05.006 · Cited by 594
Normal and torsional spring constants of atomic force microscope cantilevers
Green, C. P., Lioe, H., Cleveland, J. P., Proksch, R., Mulvaney, P., & Sader, J. E. (2004) · Review of Scientific Instruments · doi:10.1063/1.1753100 · Cited by 551
Self-citationAdsorption-induced surface stress and its effects on resonance frequency of microcantilevers
Chen, G. Y., Thundat, T., Wachter, E. A., & Warmack, R. J. (1995) · Journal of Applied Physics · doi:10.1063/1.359562 · Cited by 539
Biomolecular Imaging with the Atomic Force Microscope
Hansma, H. G., & Hoh, J. H. (1994) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.bb.23.060194.000555 · Cited by 539
Sensors—An effective approach for the detection of explosives
Singh, S. (2007) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.02.018 · Cited by 499
Reduced Graphene Oxide‐GelMA Hybrid Hydrogels as Scaffolds for Cardiac Tissue Engineering
Shin, S. R., Zihlmann, C., Akbari, M., Assawes, P., Cheung, L., Zhang, K., Manoharan, V., Zhang, Y. S., Yüksekkaya, M., Wan, K., et al. (2016) · Small · doi:10.1002/smll.201600178 · Cited by 497
Short cantilevers for atomic force microscopy
Walters, D. A., Cleveland, J. P., Thomson, N. H., Hansma, P. K., Wendman, M. A., Gurley, G., & Elings, V. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147177 · Cited by 494
Self-citationNoy, A., Vezenov, D. V., & Lieber, C. M. (1997) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.27.1.381 · Cited by 478
Nanoscale Mapping of the Elasticity of Microbial Cells by Atomic Force Microscopy
Touhami, A., Nysten, B., & Dufrêne, Y. F. (2003) · Langmuir · doi:10.1021/la034136x · Cited by 466
Capillary Forces between Two Spheres with a Fixed Volume Liquid Bridge: Theory and Experiment
Rabinovich, Y. I., Esayanur, M. S., & Moudgil, B. M. (2005) · Langmuir · doi:10.1021/la0517639 · Cited by 463
Comparison of calibration methods for atomic-force microscopy cantilevers
Burnham, N. A., Chen, X., Hodges, C. S., Matei, G. A., Thoreson, E. J., Roberts, C. J., Davies, M. C., & Tendler, S. J. B. (2003) · Nanotechnology · doi:10.1088/0957-4484/14/1/301 · Cited by 458
Sensing specific molecular interactions with the atomic force microscope
Florin, E.-L., Rief, M., Lehmann, H., Ludwig, M., Dornmair, C., Moy, V. T., & Gaub, H. E. (1995) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(95)99227-c · Cited by 455
Stolz, M., Raiteri, R., Daniels, A. U., VanLandingham, M. R., Baschong, W., & Aebi, U. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74375-1 · Cited by 454
Leite, F. L., Bueno, C. C., Da Róz, A. L., Ziemath, E. C., & Oliveira, O. N. (2012) · International Journal of Molecular Sciences · doi:10.3390/ijms131012773 · Cited by 453
Bacterial Recognition of Mineral Surfaces: Nanoscale Interactions Between Shewanella and α-FeOOH
Lower, S. K., Hochella, M. F., & Beveridge, T. J. (2001) · Science · doi:10.1126/science.1059567 · Cited by 439
Vezenov, D. V., Noy, A., Rozsnyai, L. F., & Lieber, C. M. (1997) · Journal of the American Chemical Society · doi:10.1021/ja963375m · Cited by 438
An improved wedge calibration method for lateral force in atomic force microscopy
Varenberg, M., Etsion, I., & Halperin, G. (2003) · Review of Scientific Instruments · doi:10.1063/1.1584082 · Cited by 427
Thermal and ambient-induced deflections of scanning force microscope cantilevers
Thundat, T., Warmack, R. J., Chen, G. Y., & Allison, D. P. (1994) · Applied Physics Letters · doi:10.1063/1.111407 · Cited by 419
Surface morphology and mechanical properties of MDCK monolayers by atomic force microscopy
Hoh, J. H., & Schoenenberger, C.-A. (1994) · Journal of Cell Science · doi:10.1242/jcs.107.5.1105 · Cited by 418
Ziegler, C. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2694-y · Cited by 414
Adhesion and Friction Forces between Spherical Micrometer-Sized Particles
Heim, L.-O., Blum, J., Preuss, M., & Butt, H.-J. (1999) · Physical Review Letters · doi:10.1103/physrevlett.83.3328 · Cited by 411
Measuring elasticity of biological materials by atomic force microscopy
Vinckier, A., & Semenza, G. (1998) · FEBS Letters · doi:10.1016/s0014-5793(98)00592-4 · Cited by 386
AFM: a versatile tool in biophysics
Alessandrini, A., & Facci, P. (2005) · Measurement Science and Technology · doi:10.1088/0957-0233/16/6/r01 · Cited by 384
Single molecule force spectroscopy in biology using the atomic force microscope
Zlatanova, J., Lindsay, S. M., & Leuba, S. H. (2000) · Progress in Biophysics and Molecular Biology · doi:10.1016/s0079-6107(00)00014-6 · Cited by 375
Guhados, G., Wan, W., & Hutter, J. L. (2005) · Langmuir · doi:10.1021/la0504311 · Cited by 374
Lévy, R., & Maaloum, M. (2002) · Nanotechnology · doi:10.1088/0957-4484/13/1/307 · Cited by 366
Kis, A., Kasas, S., Babić, B., Kulik, A. J., Benoît, W., Briggs, G. A. D., Schönenberger, C., Catsicas, S., & Forró, L. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.248101 · Cited by 353
Effect of Surface Wettability on the Adhesion of Proteins
Sethuraman, A., Han, M., Kane, R. S., & Belfort, G. (2004) · Langmuir · doi:10.1021/la049454q · Cited by 344
Detection of Antigen−Antibody Binding Events with the Atomic Force Microscope
Allen, S., Chen, X., Davies, J., Davies, M. C., Dawkes, A. C., Edwards, J. C., Roberts, C. J., Sefton, J., Tendler, S. J. B., & Williams, P. M. (1997) · Biochemistry · doi:10.1021/bi962531z · Cited by 341
Chon, J. W. M., Mulvaney, P., & Sader, J. E. (2000) · Journal of Applied Physics · doi:10.1063/1.372455 · Cited by 338
Lateral, normal, and longitudinal spring constants of atomic force microscopy cantilevers
Neumeister, J. M., & Ducker, W. A. (1994) · Review of Scientific Instruments · doi:10.1063/1.1144646 · Cited by 334
Adhesive and Friction Forces between Chemically Modified Silicon and Silicon Nitride Surfaces
Tsukruk, V. V., & Bliznyuk, V. N. (1998) · Langmuir · doi:10.1021/la970367q · Cited by 318
Elastin: a representative ideal protein elastomer
Urry, D. W., Hugel, T., Seitz, M., Gaub, H. E., Sheiba, L., Dea, J., Xu, J., & Parker, T. (2002) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.2001.1023 · Cited by 297
Formation Mechanisms and Aggregation Behavior of Borohydride Reduced Silver Particles
Van Hyning, D. L., & Zukoski, C. F. (1998) · Langmuir · doi:10.1021/la980325h · Cited by 291
Lio, A., Charych, D. H., & Salmeron, M. (1997) · The Journal of Physical Chemistry B · doi:10.1021/jp963918e · Cited by 286
Spring constant calibration of atomic force microscope cantilevers of arbitrary shape
Sader, J. E., Sanelli, J. A., Adamson, B. D., Monty, J. P., Wei, X., Crawford, S. A., Friend, J. R., Marusic, I., Mulvaney, P., & Bieske, E. J. (2012) · Review of Scientific Instruments · doi:10.1063/1.4757398 · Cited by 283
Yamamoto, S., Ejaz, M., Tsujii, Y., & Fukuda, T. (2000) · Macromolecules · doi:10.1021/ma991988o · Cited by 282
A method for determining the spring constant of cantilevers for atomic force microscopy
Torii, A., Sasaki, M., Hane, K., & Okuma, S. (1996) · Measurement Science and Technology · doi:10.1088/0957-0233/7/2/010 · Cited by 282
Modulation of Cellular Mechanics during Osteogenic Differentiation of Human Mesenchymal Stem Cells
Titushkin, I., & Cho, M. (2007) · Biophysical Journal · doi:10.1529/biophysj.107.107797 · Cited by 282
Surface and Capillary Forces Affecting Air Bubble−Particle Interactions in Aqueous Electrolyte
Fielden, M. L., Hayes, R. A., & Ralston, J. (1996) · Langmuir · doi:10.1021/la960145c · Cited by 273
Measuring surface forces in aqueous electrolyte solution with the atomic force microscope
Butt, H.-J., Jaschke, M., & Ducker, W. (1995) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(95)01800-t · Cited by 273
Direct Measurement of Particle−Bubble Interactions in Aqueous Electrolyte: Dependence on Surfactant
Preuss, M., & Butt, H.-J. (1998) · Langmuir · doi:10.1021/la971349b · Cited by 267
Hartley, P. G., Larson, I., & Scales, P. J. (1997) · Langmuir · doi:10.1021/la960997c · Cited by 266
Probing Bacterial Electrosteric Interactions Using Atomic Force Microscopy
Camesano, T. A., & Logan, B. E. (2000) · Environmental Science & Technology · doi:10.1021/es9913176 · Cited by 263
Effect of Molecular Scale Roughness of Glass Beads on Colloidal and Bacterial Deposition
Shellenberger, K., & Logan, B. E. (2002) · Environmental Science & Technology · doi:10.1021/es015515k · Cited by 261
Techniques for measuring surface forces
Claesson, P. M., Ederth, T., Bergeron, V., & Rutland, M. W. (1996) · Advances in Colloid and Interface Science · doi:10.1016/0001-8686(96)00302-8 · Cited by 260
Chemical and Biochemical Analysis Using Scanning Force Microscopy
Takano, H., Kenseth, J. R., Wong, S.-S., O'Brie, J. C., & Porter, M. D. (1999) · Chemical Reviews · doi:10.1021/cr9801317 · Cited by 259
Microcantilever resonance-based DNA detection with nanoparticle probes
Su, M., Li, S., & Dravid, V. P. (2003) · Applied Physics Letters · doi:10.1063/1.1576915 · Cited by 253
Adhesion Forces Measured by Atomic Force Microscopy in Humid Air
Sedin, D. L., & Rowlen, K. L. (2000) · Analytical Chemistry · doi:10.1021/ac991198c · Cited by 252
Silica Surfaces Lubrication by Hydrated Cations Adsorption from Electrolyte Solutions
Donose, B. C., Vakarelski, I. U., & Higashitani, K. (2005) · Langmuir · doi:10.1021/la047609o · Cited by 136
Adhesion between Silica Particle and Mica Surfaces in Water and Electrolyte Solutions
Vakarelski, I. U., Ishimura, K., & Higashitani, K. (2000) · Journal of Colloid and Interface Science · doi:10.1006/jcis.2000.6884 · Cited by 109
Mullin, N., & Hobbs, J. K. (2014) · Review of Scientific Instruments · doi:10.1063/1.4901221 · Cited by 58
Dynamic Features of Short-Range Interaction Force and Adhesion in Solutions
Vakarelski, I. U., & Higashitani, K. (2001) · Journal of Colloid and Interface Science · doi:10.1006/jcis.2001.7793 · Cited by 51
Applications of biosensing atomic force microscopy in monitoring drug and nanoparticle delivery
Lamprecht, C., Hinterdorfer, P., & Ebner, A. (2014) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2014.917078 · Cited by 46
Metadata
- Authors
- Cleveland, J. P., Manne, S., Bocek, D., & Hansma, P. K.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1993-02-01
- Volume
- 64
- Issue
- 2
- Pages
- 403-405
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2053787721
- Cited by
- 1,642
- References
- 10
- FWCI
- 18.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.