Absorption by water increases fluorescence image contrast of biological tissue in the shortwave infrared
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Significance: Shortwave infrared (SWIR) fluorescence imaging is a tool for visualizing biological processes deep within tissue or living animals. Our study shows that the contrast in a SWIR fluorescence image is primarily mediated by the absorptivity of the tissue, and can therefore be tuned through deliberate selection of imaging wavelength. We show, for example, that, in 3D tissue phantoms and in brain vasculature in vivo in mice, imaging at SWIR wavelengths of the highest water absorptivity results in the greatest fluorescence contrast. We further demonstrate, in microscopy of ex vivo mouse liver tissue, that imaging at wavelengths of high tissue absorptivity can also increase imaging penetration depth, and use a theoretical contrast model to explain this effect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A clearer vision for in vivo imaging
Weissleder, R. (2001) · Nature Biotechnology · doi:10.1038/86684 · Cited by 3,839
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
Bashkatov, A. N., Genina, E. A., Kochubey, V. I., & Tuchin, V. V. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/004 · Cited by 1,720 · cited 1×
“Studies in 2D tissue-mimicking phantoms predict fluorescent contrast to be the highest between 700 nm and 1,400 nm and between 1,500 nm and 1,600 nm (32), corresponding to the minima in the attenuation spectra of biological tissues (29, 33).”
BackgroundMultifunctional in vivo vascular imaging using near-infrared II fluorescence
Hong, G., Lee, J. C., Robinson, J. T., Raaz, U., Xie, L., Huang, N. F., Cooke, J. P., & Dai, H. (2012) · Nature Medicine · doi:10.1038/nm.2995 · Cited by 995
Carr, J. A., Franke, D., Caram, J. R., Perkinson, C. F., Saif, M., Askoxylakis, V., Datta, M., Fukumura, D., Jain, R. K., Bawendi, M. G., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1718917115 · Cited by 721 · cited 1×
“More recently, it was also shown that NIR dyes, which are commercially available and approved for clinical use, can be used for many SWIR imaging applications (18).”
BackgroundSelf-citationNext-generation in vivo optical imaging with short-wave infrared quantum dots
Bruns, O. T., Bischof, T. S., Harris, D. K., Franke, D., Shi, Y., Riedemann, L., Bartelt, A., Jaworski, F. B., Carr, J. A., Rowlands, C. J., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0056 · Cited by 686
Self-citationRational Design of Molecular Fluorophores for Biological Imaging in the NIR‐II Window
Yang, Q., Ma, Z., Wang, H., Zhou, B., Zhu, S., Zhong, Y., Wang, J., Wan, H., Antaris, A., Ma, R., et al. (2017) · Advanced Materials · doi:10.1002/adma.201605497 · Cited by 467
Wilson, R. H., Nadeau, K. P., Jaworski, F. B., Tromberg, B. J., & Durkin, A. J. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.3.030901 · Cited by 415
Flavylium Polymethine Fluorophores for Near‐ and Shortwave Infrared Imaging
Cosco, E. D., Caram, J. R., Bruns, O. T., Franke, D., Day, R. A., Farr, E. P., Bawendi, M. G., & Sletten, E. M. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201706974 · Cited by 415
Self-citation
Cited by
Near-infrared luminescence high-contrast in vivo biomedical imaging
Chen, Y., Wang, S., & Zhang, F. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-022-00002-8 · Cited by 566
In vivo NIR-II fluorescence imaging for biology and medicine
Wang, F., Zhong, Y., Bruns, O., Liang, Y., & Dai, H. (2024) · Nature Photonics · doi:10.1038/s41566-024-01391-5 · Cited by 564
“Moderate light absorption by water in the 1,400–1,500-nm range was shown to enhance NIR-II image contrast due to the fact that multiply-scattered diffusive light decays faster than ballistic light 30,31 .”
Self-citationLiu, Y., Li, Y., Koo, S., Sun, Y., Liu, Y., Liu, X., Pan, Y., Zhang, Z., Du, M., Lu, S., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00553 · Cited by 537
Spotlight on Luminescence Thermometry: Basics, Challenges, and Cutting‐Edge Applications
Brites, C. D. S., Marin, R., Suta, M., Carneiro Neto, A. N., Ximendes, E., Jaque, D., & Carlos, L. D. (2023) · Advanced Materials · doi:10.1002/adma.202302749 · Cited by 464
Perfecting and extending the near-infrared imaging window
Feng, Z., Tang, T., Wu, T., Yu, X., Zhang, Y., Wang, M., Zheng, J., Ying, Y., Chen, S., Zhou, J., et al. (2021) · Light: Science & Applications · doi:10.1038/s41377-021-00628-0 · Cited by 394
Cosco, E. D., Spearman, A. L., Ramakrishnan, S., Lingg, J. G. P., Saccomano, M., Pengshung, M., Arús, B. A., Wong, K. C. Y., Glasl, S., Ntziachristos, V., et al. (2020) · Nature Chemistry · doi:10.1038/s41557-020-00554-5 · Cited by 337
Self-citationNear-infrared II fluorescence imaging
Schmidt, E. L., Ou, Z., Ximendes, E., Cui, H., Keck, C. H. C., Jaque, D., & Hong, G. (2024) · Nature Reviews Methods Primers · doi:10.1038/s43586-024-00301-x · Cited by 331
Cellular and Molecular Probing of Intact Human Organs
Zhao, S., Todorov, M. I., Cai, R., -Maskari, R. A., Steinke, H., Kemter, E., Mai, H., Rong, Z., Warmer, M., Stanic, K., et al. (2020) · Cell · doi:10.1016/j.cell.2020.01.030 · Cited by 292
“First, we used SWIR (short-wave infrared) imaging light at 1450 nm wavelength and visualized the text through the intact cleared human brain (Figure 3B and Figure S3B) (Bruns et al., 2017; Carr et al., 2018).”
Self-citationA New Generation of NIR‐II Probes: Lanthanide‐Based Nanocrystals for Bioimaging and Biosensing
Fan, Y., & Zhang, F. (2019) · Advanced Optical Materials · doi:10.1002/adom.201801417 · Cited by 235
Shortwave Infrared Imaging with J-Aggregates Stabilized in Hollow Mesoporous Silica Nanoparticles
Chen, W., Cheng, C.-A., Cosco, E. D., Ramakrishnan, S., Lingg, J. G. P., Bruns, O. T., Zink, J. I., & Sletten, E. M. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b05195 · Cited by 202
Self-citationAchieving optical transparency in live animals with absorbing molecules
Ou, Z., Duh, Y.-S., Rommelfanger, N. J., Keck, C. H. C., Jiang, S., Brinson, K., Zhao, S., Schmidt, E. L., Wu, X., Yang, F., et al. (2024) · Science · doi:10.1126/science.adm6869 · Cited by 190
“These observations differ from the enhancement in image resolution induced by absorption; the latter displays a decrease in overall transmittance without exhibiting the overshoot behavior ( 12 , 13 ).”
BackgroundResultNIR‐II Chemiluminescence Molecular Sensor for In Vivo High‐Contrast Inflammation Imaging
Yang, Y., Wang, S., Lu, L., Zhang, Q., Yu, P., Fan, Y., & Zhang, F. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.202007649 · Cited by 186
Targeted multicolor in vivo imaging over 1,000 nm enabled by nonamethine cyanines
Bandi, V. G., Luciano, M. P., Saccomano, M., Patel, N. L., Bischof, T. S., Lingg, J. G. P., Tsrunchev, P. T., Nix, M. N., Ruehle, B., Sanders, C., et al. (2022) · Nature Methods · doi:10.1038/s41592-022-01394-6 · Cited by 184
Self-citationCosco, E. D., Arús, B. A., Spearman, A. L., Atallah, T. L., Lim, I., Leland, O. S., Caram, J. R., Bischof, T. S., Bruns, O. T., & Sletten, E. M. (2021) · Journal of the American Chemical Society · doi:10.1021/jacs.0c11599 · Cited by 183
Self-citationNanocrystals for Deep-Tissue In Vivo Luminescence Imaging in the Near-Infrared Region
Yang, Y., Jiang, Q., & Zhang, F. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00506 · Cited by 177
Two-Photon Absorption: An Open Door to the NIR-II Biological Window?
Shaw, P. A., Forsyth, E., Haseeb, F., Yang, S., Bradley, M., & Klausen, M. (2022) · Frontiers in Chemistry · doi:10.3389/fchem.2022.921354 · Cited by 75
Near‐IR Photochemistry for Biology: Exploiting the Optical Window of Tissue
Alabugin, A. (2019) · Photochemistry and Photobiology · doi:10.1111/php.13068 · Cited by 70
Highly Stable and Bright NIR-II AIE Dots for Intraoperative Identification of Ureter
Du, J., Liu, S., Zhang, P., Liu, H., Li, Y., He, W., Li, C., Chau, J. H. C., Kwok, R. T. K., Lam, J. W. Y., et al. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b22957 · Cited by 70
Wong, K. C. Y., & Sletten, E. M. (2022) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2022.102131 · Cited by 31
Mc Larney, B. E., Sonay, A. Y., Apfelbaum, E., Mostafa, N., Monette, S., Goerzen, D., Aguirre, N., Exner, R. M., Habjan, C., Isaac, E., et al. (2024) · Nature Biomedical Engineering · doi:10.1038/s41551-024-01248-w · Cited by 28
“44).”
InfluentialCharacterizing short-wave infrared fluorescence of conventional near-infrared fluorophores
Byrd, B. K., Folaron, M. R., Leonor, J. P., Strawbridge, R. R., Cao, X., Brůža, P., & Davis, S. C. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.3.035004 · Cited by 22
“ized by reduced photon scatter, minimal tissue autofluorescence, and wavelength-dependent absorption, which can be exploited to optimize image resolution and depth sensitivity.(4,5) Broad”
Background
Metadata
- Authors
- Carr, J. A., Aellen, M., Franke, D., So, P. T. C., Bruns, O. T., & Bawendi, M. G.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2018-08-27
- Volume
- 115
- Issue
- 37
- Pages
- 9080-9085
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2888799910
- Cited by
- 155
- References
- 9
- FWCI
- 5.83
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.