A review of the theory, methods and recent applications of high-throughput single-cell droplet microfluidics
The DOI matches its Crossref record; 184 of the 184 references it cites were found in a registry or an index.
Abstract
Most cell biology experiments are performed in bulk cell suspensions where cell secretions become diluted and mixed in a contiguous sample. Confinement of single cells to small, picoliter-sized droplets within a continuous phase of oil provides chemical isolation of each cell, creating individual microreactors where rare cell qualities are highlighted and otherwise undetectable signals can be concentrated to measurable levels. Recent work in microfluidics has yielded methods for the encapsulation of cells in aqueous droplets and hydrogels at kilohertz rates, creating the potential for millions of parallel single-cell experiments. However, commercial applications of high-throughput microdroplet generation and downstream sensing and actuation methods are still emerging for cells. Using fluorescence-activated cell sorting (FACS) as a benchmark for commercially available high-throughput screening, this focused review discusses the fluid physics of droplet formation, methods for cell encapsulation in liquids and hydrogels, sensors and actuators and notable biological applications of high-throughput single-cell droplet microfluidics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LATTICE BOLTZMANN METHOD FOR FLUID FLOWS
Chen, S., & Doolen, G. D. (1998) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.30.1.329 · Cited by 7,314
Observation of a single-beam gradient force optical trap for dielectric particles
Ashkin, A., Dziedzic, J. M., Bjorkholm, J. E., & Chu, S. (1986) · Optics Letters · doi:10.1364/ol.11.000288 · Cited by 7,030 · cited 1×
“The optical tweezer uses a single laser to trap a dielectric particle in three dimensions [151].”
MethodApplications of magnetic nanoparticles in biomedicine
Pankhurst, Q. A., Connolly, J., Jones, S. K., & Dobson, J. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/201 · Cited by 5,881 · cited 2×
“However, magnetic nanoparticles bound to specific proteins [156] and cells [157– 159] prior to encapsulation can provide both sensing and sorting actuation without direct control of the magnetic field [160].”
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559 · cited 1×
“These include affinity-based capture [222], size-based”
Mittal, R., & Iaccarino, G. (2005) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.37.061903.175743 · Cited by 3,472
Proposed Correlation of Data for Isothermal Two-Phase, Two-Component Flow in Pipes
Lockhart, R. W. (1949) · Chemical engineering progress · Cited by 2,727
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
DIFFUSE-INTERFACE METHODS IN FLUID MECHANICS
Anderson, D., McFadden, G. B., & Wheeler, A. A. (1998) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.30.1.139 · Cited by 2,491
Formation of droplets and bubbles in a microfluidic T-junction—scaling and mechanism of break-up
Garstecki, P., Fuerstman, M. J., Stone, H. A., & Whitesides, G. M. (2006) · Lab on a Chip · doi:10.1039/b510841a · Cited by 2,339 · cited 1×
“pressure buildup which leads to droplet generation (figure 2(a)) [46].”
BackgroundFormation of dispersions using “flow focusing” in microchannels
Anna, S. L., Bontoux, N., & Stone, H. A. (2003) · Applied Physics Letters · doi:10.1063/1.1537519 · Cited by 2,302
A Front-Tracking Method for the Computations of Multiphase Flow
Tryggvason, G., Bunner, B., Esmaeeli, A., Juric, D., Al-Rawahi, N., Tauber, W., Han, J., Nas, S., & Jan, Y.-J. (2001) · Journal of Computational Physics · doi:10.1006/jcph.2001.6726 · Cited by 2,187 · cited 1×
“Reviews of numerical solutions exist which highlight methods such as diffuse-interface [59], level set [60], fronttracking [61], immersed boundary [62] and Lattice–Boltzmann”
MethodReactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Continuous Particle Separation Through Deterministic Lateral Displacement
Huang, L. R., Cox, E. C., Austin, R. H., & Sturm, J. C. (2004) · Science · doi:10.1126/science.1094567 · Cited by 1,634
Di Carlo, D. (2009) · Lab on a Chip · doi:10.1039/b912547g · Cited by 1,627 · cited 1×
“separation by DLD [141] or inertial focusing [144], and”
MethodReview Article—Dielectrophoresis: Status of the theory, technology, and applications
Pethig, R. (2010) · Biomicrofluidics · doi:10.1063/1.3456626 · Cited by 1,270
Geometrically Mediated Breakup of Drops in Microfluidic Devices
Link, D. R., Anna, S. L., Weitz, D. A., & Stone, H. A. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.054503 · Cited by 1,202
Droplet microfluidic technology for single-cell high-throughput screening
Brouzes, E., Medkova, M., Savenelli, N., Marran, D., Twardowski, M., Hutchison, J. B., Rothberg, J. M., Link, D. R., Perrimon, N., & Samuels, M. L. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0903542106 · Cited by 1,069 · cited 2×
“These include screening cells for enzyme activity [170], screening drug libraries for cytotoxicity [15] (figure 7) and screening engineered proteins for directed evolution [217].”
BackgroundDynamics of microfluidic droplets
Baroud, C. N., Gallaire, F., & Dangla, R. (2010) · Lab on a Chip · doi:10.1039/c001191f · Cited by 1,067
Digital microfluidics: is a true lab-on-a-chip possible?
Fair, R. B. (2007) · Microfluidics and Nanofluidics · doi:10.1007/s10404-007-0161-8 · Cited by 1,063
Microdroplets in Microfluidics: An Evolving Platform for Discoveries in Chemistry and Biology
Theberge, A. B., Courtois, F., Schaerli, Y., Fischlechner, M., Abell, C., Hollfelder, F., & Huck, W. T. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906653 · Cited by 1,059
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049 · cited 1×
“Splitting and coalescence have been well-reviewed elsewhere [30, 31].”
BackgroundDroplet microfluidics for high-throughput biological assays
Guo, M. T., Rotem, A., Heyman, J. A., & Weitz, D. A. (2012) · Lab on a Chip · doi:10.1039/c2lc21147e · Cited by 1,040
Controlled microfluidic interfaces
Atencia, J., & Beebe, D. J. (2005) · Nature · doi:10.1038/nature04163 · Cited by 1,006
Dripping to Jetting Transitions in Coflowing Liquid Streams
Utada, A. S., Fernandez-Nieves, A., Stone, H. A., & Weitz, D. A. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.094502 · Cited by 965 · cited 5×
“Parts (a), (b) and (c) reprinted with permission from [35, 36, 38], respectively.”
BackgroundInfluentialL EVEL S ET M ETHODS FOR F LUID I NTERFACES
Sethian, J. A., & Smereka, P. (2003) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.35.101101.161105 · Cited by 959
Baret, J.-C., Miller, O. J., Taly, V., Ryckelynck, M., El-Harrak, A., Frenz, L., Rick, C., Samuels, M. L., Hutchison, J. B., Agresti, J. J., et al. (2009) · Lab on a Chip · doi:10.1039/b902504a · Cited by 951
Label-free cell separation and sorting in microfluidic systems
Gossett, D. R., Weaver, W. M., Mach, A. J., Hur, S. C., Tse, H. T. K., Lee, W., Amini, H., & Di Carlo, D. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3721-9 · Cited by 930
Microfluidic methods for generating continuous droplet streams
Christopher, G. F., & Anna, S. L. (2007) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/40/19/r01 · Cited by 860
Polymer microfabrication technologies for microfluidic systems
Becker, H., & Gärtner, C. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1692-2 · Cited by 860
Electric Control of Droplets in Microfluidic Devices
Link, D. R., Grasland‐Mongrain, E., Duri, A., Sarrazin, F., Cheng, Z., Cristobal, G., Márquez, M., & Weitz, D. A. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200503540 · Cited by 843
Engineers are from PDMS-land, Biologists are from Polystyrenia
Berthier, E., Young, E. W. K., & Beebe, D. (2012) · Lab on a Chip · doi:10.1039/c2lc20982a · Cited by 799
Controllable Monodisperse Multiple Emulsions
Chu, L., Utada, A. S., Shah, R. K., Kim, J., & Weitz, D. A. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200701358 · Cited by 747
Yamada, M., Nakashima, M., & Seki, M. (2004) · Analytical Chemistry · doi:10.1021/ac049863r · Cited by 746
Microfluidic Large-Scale Integration: The Evolution of Design Rules for Biological Automation
Melin, J., & Quake, S. R. (2007) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.36.040306.132646 · Cited by 738 · cited 1×
“and valves [2] in depth, we focus this section on droplet”
BackgroundTransition from squeezing to dripping in a microfluidic T-shaped junction
DE MENECH, M., GARSTECKI, P., JOUSSE, F., & STONE, H. A. (2008) · Journal of Fluid Mechanics · doi:10.1017/s002211200700910x · Cited by 728
Multifunctional Encoded Particles for High-Throughput Biomolecule Analysis
Pregibon, D. C., Toner, M., & Doyle, P. S. (2007) · Science · doi:10.1126/science.1134929 · Cited by 726
Nisisako, T., Torii, T., Takahashi, T., & Takizawa, Y. (2006) · Advanced Materials · doi:10.1002/adma.200502431 · Cited by 724
Clausell-Tormos, J., Lieber, D., Baret, J.-C., El-Harrak, A., Miller, O. J., Frenz, L., Blouwolff, J., Humphry, K. J., Köster, S., Duan, H., et al. (2008) · Chemistry & Biology · doi:10.1016/j.chembiol.2008.04.004 · Cited by 720 · cited 1×
“materials with larger 600–700 picoliter (pL) droplets [15, 81].”
BackgroundInertial microfluidics for continuous particle separation in spiral microchannels
Kuntaegowdanahalli, S. S., Bhagat, A. A. S., Kumar, G., & Papautsky, I. (2009) · Lab on a Chip · doi:10.1039/b908271a · Cited by 708
Chen, J., Ng, J., Lin, Z., & Chan, C. T. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.153 · Cited by 708
Dynamic single cell culture array
Carlo, D. D., Wu, L. Y., & Lee, L. P. (2006) · Lab on a Chip · doi:10.1039/b605937f · Cited by 707
Millisecond Kinetics on a Microfluidic Chip Using Nanoliters of Reagents
Song, H., & Ismagilov, R. F. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0354566 · Cited by 693 · cited 1×
“Serpentine channels have been employed to move samples across the field of view at discrete time intervals for fluorescent imaging, increasing total on-chip time for transient experiments [179].”
BackgroundMicrofluidic sorting of mammalian cells by optical force switching
Wang, M. M., Tu, E., Raymond, D. E., Yang, J. M., Zhang, H., Hagen, N., Dees, B., Mercer, E. M., Forster, A. H., Kariv, I., et al. (2005) · Nature Biotechnology · doi:10.1038/nbt1050 · Cited by 690
Biocompatible surfactants for water-in-fluorocarbon emulsions
Holtze, C., Rowat, A. C., Agresti, J. J., Hutchison, J. B., Angilè, F. E., Schmitz, C. H. J., Köster, S., Duan, H., Humphry, K. J., Scanga, R. A., et al. (2008) · Lab on a Chip · doi:10.1039/b806706f · Cited by 670 · cited 1×
“Since fluorocarbon oils are both hydrophobic and lipophobic, they are considered more biocompatible than lipophilic organic oils, as fluorocarbon oils are not likely to interact with aqueous solutes, biomolecules and cell membrane lipids [52].”
BackgroundOkushima, S., Nisisako, T., Torii, T., & Higuchi, T. (2004) · Langmuir · doi:10.1021/la0480336 · Cited by 656
Surfactants in droplet-based microfluidics
Baret, J.-C. (2012) · Lab Chip · doi:10.1039/c1lc20582j · Cited by 649
Free Flow Acoustophoresis: Microfluidic-Based Mode of Particle and Cell Separation
Petersson, F., Åberg, L., Swärd-Nilsson, A.-M., & Laurell, T. (2007) · Analytical Chemistry · doi:10.1021/ac070444e · Cited by 649 · cited 1×
“blood cells, platelets and leukocytes [165].”
Versatile, Fully Automated, Microfluidic Cell Culture System
Gómez-Sjöberg, R., Leyrat, A. A., Pirone, D. M., Chen, C. S., & Quake, S. R. (2007) · Analytical Chemistry · doi:10.1021/ac071311w · Cited by 625
Chip–NMR biosensor for detection and molecular analysis of cells
Lee, H., Sun, E., Ham, D., & Weissleder, R. (2008) · Nature Medicine · doi:10.1038/nm.1711 · Cited by 621 · cited 1×
“Additional studies have used microfluidic NMR hand-held devices (without droplets) to detect bacteria in unprocessed biological samples [201, 202] and for cancer cell detection [203].”
BackgroundMicrodroplets: A sea of applications?
Huebner, A., Sharma, S., Srisa-Art, M., Hollfelder, F., Edel, J. B., & deMello, A. J. (2008) · Lab on a Chip · doi:10.1039/b806405a · Cited by 619
MEMS-based micropumps in drug delivery and biomedical applications
Nisar, A., Afzulpurkar, N., Mahaisavariya, B., & Tuantranont, A. (2008) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2007.10.064 · Cited by 614
Droplet formation in a microchannel network
Nisisako, T., Torii, T., & Higuchi, T. (2002) · Lab Chip · doi:10.1039/b108740c · Cited by 607 · cited 8×
“While droplet generation may be driven using active methods such as piezoelectric actuators [33] and electric fields [34], aqueous monodisperse droplets are most commonly formed in continuous pressure-driven nozzles with flow focusing [35] (figure 1(a)), co-flowing [36] (figure 1(b)), or T-junction [37] (figure 2(a))…”
InfluentialBonding of thermoplastic polymer microfluidics
Tsao, C.-W., & DeVoe, D. L. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-008-0361-x · Cited by 601
Magnetic nanoparticle biosensors
Haun, J. B., Yoon, T., Lee, H., & Weissleder, R. (2010) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.84 · Cited by 550
Mezzenga, R., & Fischer, P. (2013) · Reports on Progress in Physics · doi:10.1088/0034-4885/76/4/046601 · Cited by 545
Quantitative and sensitive detection of rare mutations using droplet-based microfluidics
Pekin, D., Skhiri, Y., Baret, J.-C., Le Corre, D., Mazutis, L., Ben Salem, C., Millot, F., El Harrak, A., Hutchison, J. B., Larson, J. W., et al. (2011) · Lab on a Chip · doi:10.1039/c1lc20128j · Cited by 540
Drop-based microfluidic devices for encapsulation of single cells
Köster, S., Angilè, F. E., Duan, H., Agresti, J. J., Wintner, A., Schmitz, C., Rowat, A. C., Merten, C. A., Pisignano, D., Griffiths, A. D., et al. (2008) · Lab on a Chip · doi:10.1039/b802941e · Cited by 518
He, M., Edgar, J. S., Jeffries, G. D. M., Lorenz, R. M., Shelby, J. P., & Chiu, D. T. (2005) · Analytical Chemistry · doi:10.1021/ac0480850 · Cited by 518
Controlled encapsulation of single-cells into monodisperse picolitre drops
Edd, J. F., Di Carlo, D., Humphry, K. J., Köster, S., Irimia, D., Weitz, D. A., & Toner, M. (2008) · Lab on a Chip · doi:10.1039/b805456h · Cited by 511
Self-citationRecent advances in microscale pumping technologies: a review and evaluation
Iverson, B. D., & Garimella, S. V. (2008) · Microfluidics and Nanofluidics · doi:10.1007/s10404-008-0266-8 · Cited by 497
One-Step Fabrication of Supramolecular Microcapsules from Microfluidic Droplets
Zhang, J., Coulston, R. J., Jones, S. T., Geng, J., Scherman, O. A., & Abell, C. (2012) · Science · doi:10.1126/science.1215416 · Cited by 456 · cited 4×
“SERS was used to investigate the internal contents of gold-nanoparticle laden shells fabricated using microfluidics [104] and to reduce the interrogation time of E.”
BackgroundMethodInfluentialMicromixing Within Microfluidic Devices
Capretto, L., Cheng, W., Hill, M., & Zhang, X. (2011) · Topics in Current Chemistry · doi:10.1007/128_2011_150 · Cited by 448
Nanoparticles at fluid interfaces
Bresme, F., & Oettel, M. (2007) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/19/41/413101 · Cited by 444 · cited 1×
“More complete reviews of surfactants [51] and nanoparticle pickering emulsions [58] are available elsewhere.”
BackgroundBoedicker, J. Q., Li, L., Kline, T. R., & Ismagilov, R. F. (2008) · Lab on a Chip · doi:10.1039/b804911d · Cited by 438
Marker-specific sorting of rare cells using dielectrophoresis
Hu, X., Bessette, P. H., Qian, J., Meinhart, C. D., Daugherty, P. S., & Soh, H. T. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507719102 · Cited by 428
Microfluidic systems for chemical kinetics that rely on chaotic mixing in droplets
Bringer, M. R., Gerdts, C. J., Song, H., Tice, J. D., & Ismagilov, R. F. (2004) · Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2003.1364 · Cited by 416
Equilibrium Separation and Filtration of Particles Using Differential Inertial Focusing
Di Carlo, D., Edd, J. F., Irimia, D., Tompkins, R. G., & Toner, M. (2008) · Analytical Chemistry · doi:10.1021/ac702283m · Cited by 413 · cited 1×
“Combining this straight-channel effect with spiral [146, 147] and asymmetrical [148, 149] channels introduces secondary Dean flows, forcing larger objects to move toward the inside channel wall while smaller objects stay further from the wall.”
BackgroundSelf-citationRaman Microscopic Analysis of Single Microbial Cells
Huang, W. E., Griffiths, R. I., Thompson, I. P., Bailey, M. J., & Whiteley, A. S. (2004) · Analytical Chemistry · doi:10.1021/ac049753k · Cited by 411
Ordered and Disordered Patterns in Two-Phase Flows in Microchannels
Dreyfus, R., Tabeling, P., & Willaime, H. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.144505 · Cited by 404
Microfluidics for single cell analysis
Yin, H., & Marshall, D. (2012) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2011.11.002 · Cited by 394 · cited 1×
“techniques [110, 111] and microfluidic pumps [112, 113]”
Single-phase liquid friction factors in microchannels
Steinke, M. E., & Kandlikar, S. G. (2006) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2006.01.016 · Cited by 392
van Dongen, S. F. M., de Hoog, H.-P. M., Peters, R. J. R. W., Nallani, M., Nolte, R. J. M., & van Hest, J. C. M. (2009) · Chemical Reviews · doi:10.1021/cr900072y · Cited by 386
Pillar-induced droplet merging in microfluidic circuits
Niu, X., Gulati, S., Edel, J. B., & deMello, A. J. (2008) · Lab on a Chip · doi:10.1039/b813325e · Cited by 374
Quantitative detection of protein expression in single cells using droplet microfluidics
Huebner, A., Srisa-Art, M., Holt, D., Abell, C., Hollfelder, F., deMello, A. J., & Edel, J. B. (2007) · Chemical Communications · doi:10.1039/b618570c · Cited by 370
Surface acoustic wave (SAW) directed droplet flow in microfluidics for PDMS devices
Franke, T., Abate, A. R., Weitz, D. A., & Wixforth, A. (2009) · Lab on a Chip · doi:10.1039/b906819h · Cited by 369
Surface acoustic wave actuated cell sorting (SAWACS)
Franke, T., Braunmüller, S., Schmid, L., Wixforth, A., & Weitz, D. A. (2010) · Lab on a Chip · doi:10.1039/b915522h · Cited by 363
Petersson, F., Nilsson, A., Holm, C., Jönsson, H., & Laurell, T. (2005) · Lab Chip · doi:10.1039/b405748c · Cited by 360
Light at work: The use of optical forces for particle manipulation, sorting, and analysis
Jonáš, A., & Zemánek, P. (2008) · ELECTROPHORESIS · doi:10.1002/elps.200800484 · Cited by 356
Droplet microfluidics: recent developments and future applications
Casadevall i Solvas, X., & deMello, A. (2011) · Chem. Commun. · doi:10.1039/c0cc02474k · Cited by 353
Prabaharan, M., & Mano, J. F. (2006) · Macromolecular Bioscience · doi:10.1002/mabi.200600164 · Cited by 347
Microfluidic high-throughput encapsulation and hydrodynamic self-sorting of single cells
Chabert, M., & Viovy, J.-L. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0708321105 · Cited by 344 · cited 4×
“In one study, self-sorting of cell-containing droplets from empty droplets provided singly encapsulated cells at a throughput of 160 cells s−1 following a 1 kHz droplet generation rate [84] (figure 3(a)).”
BackgroundMethodInfluentialLecault, V., VanInsberghe, M., Sekulovic, S., Knapp, D. J. H. F., Wohrer, S., Bowden, W., Viel, F., McLaughlin, T., Jarandehei, A., Miller, M., et al. (2011) · Nature Methods · doi:10.1038/nmeth.1614 · Cited by 335
Bibette, J., Calderon, F. L., & Poulin, P. (1999) · Reports on Progress in Physics · doi:10.1088/0034-4885/62/6/203 · Cited by 329
Boedicker, J. Q., Vincent, M. E., & Ismagilov, R. F. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200901550 · Cited by 327
1-Million droplet array with wide-field fluorescence imaging for digital PCR
Hatch, A. C., Fisher, J. S., Tovar, A. R., Hsieh, A. T., Lin, R., Pentoney, S. L., Yang, D. L., & Lee, A. P. (2011) · Lab on a Chip · doi:10.1039/c1lc20561g · Cited by 317
Walter, A., März, A., Schumacher, W., Rösch, P., & Popp, J. (2011) · Lab on a Chip · doi:10.1039/c0lc00536c · Cited by 309
Fabrication of Monodisperse Gel Shells and Functional Microgels in Microfluidic Devices
Kim, J., Utada, A. S., Fernández‐Nieves, A., Hu, Z., & Weitz, D. A. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200604206 · Cited by 307
Multifunctional Superparamagnetic Janus Particles
Yuet, K. P., Hwang, D. K., Haghgooie, R., & Doyle, P. S. (2009) · Langmuir · doi:10.1021/la903348s · Cited by 299
Single-Phase Liquid Friction Factors in Microchannels
Steinke, M. E., & Kandlikar, S. G. (2005) · ASME 3rd International Conference on Microchannels and Minichannels, Parts A and B · doi:10.1115/icmm2005-75112 · Cited by 289 · cited 1×
“Upstream of the nozzle, aqueous and oil microchannel flows are relatively straightforward to resolve [66].”
BackgroundMicrofluidic Generation of Multifunctional Quantum Dot Barcode Particles
Zhao, Y., Shum, H. C., Chen, H., Adams, L. L. A., Gu, Z., & Weitz, D. A. (2011) · Journal of the American Chemical Society · doi:10.1021/ja200729w · Cited by 264
Microfluidic Encapsulation of Cells in Polymer Microgels
Velasco, D., Tumarkin, E., & Kumacheva, E. (2012) · Small · doi:10.1002/smll.201102464 · Cited by 262
Fallah-Araghi, A., Baret, J.-C., Ryckelynck, M., & Griffiths, A. D. (2012) · Lab on a Chip · doi:10.1039/c2lc21035e · Cited by 261 · cited 1×
“These include screening cells for enzyme activity [170], screening drug libraries for cytotoxicity [15] (figure 7) and screening engineered proteins for directed evolution [217].”
BackgroundOverview of single-cell analyses: microdevices and applications
Lindström, S., & Andersson-Svahn, H. (2010) · Lab on a Chip · doi:10.1039/c0lc00150c · Cited by 260
Dropspots: a picoliter array in a microfluidic device
Schmitz, C. H. J., Rowat, A. C., Köster, S., & Weitz, D. A. (2009) · Lab Chip · doi:10.1039/b809670h · Cited by 250
Single cell Raman spectroscopy for cell sorting and imaging
Li, M., Xu, J., Romero-Gonzalez, M., Banwart, S. A., & Huang, W. E. (2012) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2011.11.019 · Cited by 250 · cited 3×
“Interrogation times may be reduced, however, by increasing the laser power [187, 189], or by using enhanced Raman spectroscopy techniques.”
BackgroundInfluentialOn water-in-oil emulsions stabilized by fine solids
Yan, N., Gray, M. R., & Masliyah, J. H. (2001) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/s0927-7757(01)00748-8 · Cited by 242
Controlled Synthesis of Cell-Laden Microgels by Radical-Free Gelation in Droplet Microfluidics
Rossow, T., Heyman, J. A., Ehrlicher, A. J., Langhoff, A., Weitz, D. A., Haag, R., & Seiffert, S. (2012) · Journal of the American Chemical Society · doi:10.1021/ja300460p · Cited by 233 · cited 1×
“An additional study encapsulated and cultivated yeast cells in polyethyleneglycol (PEG) and hyperbranched polyglycerol (hPG) without the use of cellharming polymerization initiators [95] (figure 4).”
BackgroundHigh-Throughput Single Copy DNA Amplification and Cell Analysis in Engineered Nanoliter Droplets
Kumaresan, P., Yang, C. J., Cronier, S. A., Blazej, R. G., & Mathies, R. A. (2008) · Analytical Chemistry · doi:10.1021/ac800327d · Cited by 226
Shining Light on the Microbial World
(2010) · Advances in Applied Microbiology · doi:10.1016/s0065-2164(10)70005-8 · Cited by 225
Mastrobattista, E., Taly, V., Chanudet, E., Treacy, P., Kelly, B. T., & Griffiths, A. D. (2005) · Chemistry & Biology · doi:10.1016/j.chembiol.2005.09.016 · Cited by 222
Microgels and microcapsules in peptide and protein drug delivery
Bysell, H., Månsson, R., Hansson, P., & Malmsten, M. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.08.005 · Cited by 215
Micro-NMR for Rapid Molecular Analysis of Human Tumor Samples
Haun, J. B., Castro, C. M., Wang, R., Peterson, V. M., Marinelli, B. S., Lee, H., & Weissleder, R. (2011) · Science Translational Medicine · doi:10.1126/scitranslmed.3002048 · Cited by 214
Sohel Murshed, S. M., Tan, S.-H., & Nguyen, N.-T. (2008) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/41/8/085502 · Cited by 214
A microdroplet dilutor for high-throughput screening
Niu, X., Gielen, F., Edel, J. B., & deMello, A. J. (2011) · Nature Chemistry · doi:10.1038/nchem.1046 · Cited by 199
Ultrasensitive Detection of Bacteria Using Core–Shell Nanoparticles and an NMR‐Filter System
Lee, H., Yoon, T., & Weissleder, R. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200901791 · Cited by 196 · cited 1×
“Additional studies have used microfluidic NMR hand-held devices (without droplets) to detect bacteria in unprocessed biological samples [201, 202] and for cancer cell detection [203].”
BackgroundEun, Y.-J., Utada, A. S., Copeland, M. F., Takeuchi, S., & Weibel, D. B. (2011) · ACS Chemical Biology · doi:10.1021/cb100336p · Cited by 192
Bøyum, A. (1984) · Methods in Enzymology · doi:10.1016/s0076-6879(84)08076-9 · Cited by 192
Acoustofluidics 1: Governing equations in microfluidics
Bruus, H. (2011) · Lab on a Chip · doi:10.1039/c1lc20658c · Cited by 191 · cited 1×
“only on droplet size, shape and density [164].”
BackgroundSingle-Cell Analysis in Biotechnology, Systems Biology, and Biocatalysis
Fritzsch, F. S. O., Dusny, C., Frick, O., & Schmid, A. (2012) · Annual Review of Chemical and Biomolecular Engineering · doi:10.1146/annurev-chembioeng-062011-081056 · Cited by 190
Droplet breakup in microfluidic junctions of arbitrary angles
Ménétrier-Deremble, L., & Tabeling, P. (2006) · Physical Review E · doi:10.1103/physreve.74.035303 · Cited by 190 · cited 1×
“Symmetric splitting junctions [114] (equal-sized outlet channels each with equal flow) provide equal-sized daughter droplets while asymmetric junctions [118] provide one larger droplet and one smaller droplet.”
BackgroundBeating Poisson encapsulation statistics using close-packed ordering
Abate, A. R., Chen, C.-H., Agresti, J. J., & Weitz, D. A. (2009) · Lab on a Chip · doi:10.1039/b909386a · Cited by 189
Oligonucleotide-functionalized hydrogels as stimuli responsive materials and biosensors
Liu, J. (2011) · Soft Matter · doi:10.1039/c1sm05284e · Cited by 189
Zhang, K., Liang, Q., Ma, S., Mu, X., Hu, P., Wang, Y., & Luo, G. (2009) · Lab on a Chip · doi:10.1039/b906229g · Cited by 173
The potential of microfluidic water-in-oil droplets in experimental biology
Schaerli, Y., & Hollfelder, F. (2009) · Molecular BioSystems · doi:10.1039/b907578j · Cited by 171
Bernath, K., Hai, M., Mastrobattista, E., Griffiths, A. D., Magdassi, S., & Tawfik, D. S. (2004) · Analytical Biochemistry · doi:10.1016/j.ab.2003.10.005 · Cited by 165 · cited 1×
“machines yet retain all the benefits of encapsulation [220, 221].”
BackgroundFrom Microdroplets to Microfluidics: Selective Emulsion Separation in Microfluidic Devices
Fidalgo, L. M., Whyte, G., Bratton, D., Kaminski, C. F., Abell, C., & Huck, W. T. S. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200704903 · Cited by 165
An integrated optofluidic platform for Raman-activated cell sorting
Lau, A. Y., Lee, L. P., & Chan, J. W. (2008) · Lab on a Chip · doi:10.1039/b803598a · Cited by 164
Progress technology in microencapsulation methods for cell therapy
Rabanel, J., Banquy, X., Zouaoui, H., Mokhtar, M., & Hildgen, P. (2009) · Biotechnology Progress · doi:10.1002/btpr.226 · Cited by 162
Dynamic analysis of MAPK signaling using a high-throughput microfluidic single-cell imaging platform
Taylor, R. J., Falconnet, D., Niemistö, A., Ramsey, S. A., Prinz, S., Shmulevich, I., Galitski, T., & Hansen, C. L. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0813416106 · Cited by 161
Kim, H., Luo, D., Link, D., Weitz, D. A., Marquez, M., & Cheng, Z. (2007) · Applied Physics Letters · doi:10.1063/1.2790785 · Cited by 161 · cited 1×
“and electric fields [34], aqueous monodisperse droplets”
Stable, biocompatible lipid vesicle generation by solvent extraction-based droplet microfluidics
Teh, S., Khnouf, R., Fan, H., & Lee, A. P. (2011) · Biomicrofluidics · doi:10.1063/1.3665221 · Cited by 156
Monitoring of Real-Time Streptavidin−Biotin Binding Kinetics Using Droplet Microfluidics
Srisa‐Art, M., Dyson, E. C., deMello, A. J., & Edel, J. B. (2008) · Analytical Chemistry · doi:10.1021/ac801199k · Cited by 155
Joensson, H. N., Samuels, M. L., Brouzes, E. R., Medkova, M., Uhlén, M., Link, D. R., & Svahn, H. A. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200804326 · Cited by 154
Electroporation of Cells in Microfluidic Droplets
Zhan, Y., Wang, J., Bao, N., & Lu, C. (2009) · Analytical Chemistry · doi:10.1021/ac9001172 · Cited by 146
A double droplet trap system for studying mass transport across a droplet-droplet interface
Bai, Y., He, X., Liu, D., Patil, S. N., Bratton, D., Huebner, A., Hollfelder, F., Abell, C., & Huck, W. T. S. (2010) · Lab on a Chip · doi:10.1039/b925133b · Cited by 146
Zhang, H., Jenkins, G., Zou, Y., Zhu, Z., & Yang, C. J. (2012) · Analytical Chemistry · doi:10.1021/ac2033084 · Cited by 140 · cited 15×
“Washing in aqueous media then facilitates a direct coupling of encapsulated cells to standard FACS [218, 219] (figure 8).”
BackgroundInfluentialLéonard, A. F., Dandoy, P., Danloy, E., Leroux, G., Meunier, C. F., Rooke, J. C., & Su, B. (2011) · Chemical Society Reviews · doi:10.1039/c0cs00024h · Cited by 138
Joensson, H. N., Samuels, M. L., Brouzes, E. R., Medkova, M., Uhlén, M., Link, D. R., & Svahn, H. A. (2009) · Angewandte Chemie · doi:10.1002/ange.200804326 · Cited by 131
Agarose droplet microfluidics for highly parallel and efficient single molecule emulsion PCR
Leng, X., Zhang, W., Wang, C., Cui, L., & Yang, C. J. (2010) · Lab on a Chip · doi:10.1039/c0lc00145g · Cited by 131
Cell manipulation with magnetic particles toward microfluidic cytometry
Liu, C., Stakenborg, T., Peeters, S., & Lagae, L. (2009) · Journal of Applied Physics · doi:10.1063/1.3116091 · Cited by 127
Microscale LC-MS-NMR Platform Applied to the Identification of Active Cyanobacterial Metabolites
Lin, Y., Schiavo, S., Orjala, J., Vouros, P., & Kautz, R. A. (2008) · Analytical Chemistry · doi:10.1021/ac801049k · Cited by 124
Droplet microfluidics with magnetic beads: a new tool to investigate drug–protein interactions
Lombardi, D., & Dittrich, P. S. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4302-7 · Cited by 117 · cited 1×
“Magnetic droplet sorting has been demonstrated at relatively low rates of around 10 droplets s−1 [155] and 30 droplets s−1 [161], while cell sorting has been demonstrated using flow velocities on the order of 0.”
MethodLiu, W., Kim, H. J., Lucchetta, E. M., Du, W., & Ismagilov, R. F. (2009) · Lab on a Chip · doi:10.1039/b904958d · Cited by 111
Cecchini, M. P., Hong, J., Lim, C., Choo, J., Albrecht, T., deMello, A. J., & Edel, J. B. (2011) · Analytical Chemistry · doi:10.1021/ac103329b · Cited by 109
Cai, L.-F., Zhu, Y., Du, G.-S., & Fang, Q. (2012) · Analytical Chemistry · doi:10.1021/ac2029198 · Cited by 108
Single-molecule emulsion PCR in microfluidic droplets
Zhu, Z., Jenkins, G., Zhang, W., Zhang, M., Guan, Z., & Yang, C. J. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-5914-x · Cited by 104
Monitoring single-cell bioenergetics via the coarsening of emulsion droplets
Boitard, L., Cottinet, D., Kleinschmitt, C., Brémond, N., Baudry, J., Yvert, G., & Bibette, J. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1200894109 · Cited by 103 · cited 1×
“[210, 225] has taken advantage of the tiny but non-zero”
BackgroundVincent, M. E., Liu, W., Haney, E. B., & Ismagilov, R. F. (2010) · Chemical Society Reviews · doi:10.1039/b917851a · Cited by 102
Miniaturised technologies for the development of artificial lipid bilayer systems
Zagnoni, M. (2012) · Lab on a Chip · doi:10.1039/c2lc20991h · Cited by 100 · cited 1×
“droplet pairs across an artificial lipid bilayer [228] that”
BackgroundUm, E., Lee, D.-S., Pyo, H., & Park, J. (2008) · Microfluidics and Nanofluidics · doi:10.1007/s10404-008-0268-6 · Cited by 98
Zhu, Y., & Fang, Q. (2010) · Analytical Chemistry · doi:10.1021/ac101902c · Cited by 95
Functionalization of whole‐cell bacterial reporters with magnetic nanoparticles
Zhang, D., Fakhrullin, R. F., Özmen, M., Wang, H., Wang, J., Paunov, V. N., Li, G., & Huang, W. E. (2010) · Microbial Biotechnology · doi:10.1111/j.1751-7915.2010.00228.x · Cited by 95
Opportunities for microfluidic technologies in synthetic biology
Gulati, S., Rouilly, V., Niu, X., Chappell, J., Kitney, R. I., Edel, J. B., Freemont, P. S., & deMello, A. J. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0083.focus · Cited by 94 · cited 1×
“Note that these thin membrane and core–shell methods highlight one critical role of droplet microfluidics in synthetic biology [105, 106] for both single cells and sub-cellular components.”
BackgroundElectro-Coalescence of Digitally Controlled Droplets
Niu, X., Gielen, F., deMello, A. J., & Edel, J. B. (2009) · Analytical Chemistry · doi:10.1021/ac901188n · Cited by 92
Petri dish PCR: laser-heated reactions in nanoliter droplet arrays
Kim, H., Vishniakou, S., & Faris, G. W. (2009) · Lab on a Chip · doi:10.1039/b817288a · Cited by 89 · cited 1×
“Heating using laser absorption has been exploited to reduce droplet PCR cycle times to around 10 s [128, 129].”
MethodSimović, S., & Prestidge, C. A. (2004) · Langmuir · doi:10.1021/la0491807 · Cited by 84
Prototyping of microfluidic systems using a commercial thermoplastic elastomer
Roy, E., Geißler, M., Galas, J.-C., & Veres, T. (2011) · Microfluidics and Nanofluidics · doi:10.1007/s10404-011-0789-2 · Cited by 83
Microfluidic synthesis of monodisperse PDMS microbeads as discrete oxygen sensors
Jiang, K., Thomas, P. C., Forry, S. P., DeVoe, D. L., & Raghavan, S. R. (2012) · Soft Matter · doi:10.1039/c2sm06685h · Cited by 79 · cited 1×
“In another study, oxygen-permeable PDMS microparticles were embedded with oxygen-sensitive dye for an optical readout of oxygen concentration [209].”
BackgroundChoi, K., Kim, J.-Y., Ahn, J.-H., Choi, J.-M., Im, M., & Choi, Y.-K. (2012) · Lab on a Chip · doi:10.1039/c2lc21203j · Cited by 77 · cited 1×
“On the other hand, ‘digital microfluidics’ utilizes microfabricated electrode arrays programmed to move, mix, react, analyse and split droplets through electrowetting on a dielectric-coated substrate [9, 10].”
BackgroundCommercial high speed machines open new opportunities in high throughput flow cytometry (HTFC)
Ashcroft, R. G., & Lopez, P. (2000) · Journal of Immunological Methods · doi:10.1016/s0022-1759(00)00219-2 · Cited by 77 · cited 1×
“Although FACS machines can in fact process on the order of 70 000–100 000 droplets s−1 [22, 23], singlecell encapsulation requires the use of dilute cell suspensions, causing many empty droplets and a reduction in the effective cell throughput.”
(Meth)acrylic stimulus-responsive block copolymer hydrogels
Madsen, J., & Armes, S. P. (2012) · Soft Matter · doi:10.1039/c1sm06035j · Cited by 76
Nanodroplet real-time PCR system with laser assisted heating
Kim, H., Dixit, S. S., Green, C. J., & Faris, G. W. (2008) · Optics Express · doi:10.1364/oe.17.000218 · Cited by 74 · cited 1×
“Heating using laser absorption has been exploited to reduce droplet PCR cycle times to around 10 s [128, 129].”
MethodSimultaneous measurement of reactions in microdroplets filled by concentration gradients
Damean, N., Olguin, L. F., Hollfelder, F., Abell, C., & Huck, W. T. S. (2009) · Lab on a Chip · doi:10.1039/b821021g · Cited by 69
Tunable 3D droplet self-assembly for ultra-high-density digital micro-reactor arrays
Hatch, A. C., Fisher, J. S., Pentoney, S. L., Yang, D. L., & Lee, A. P. (2011) · Lab on a Chip · doi:10.1039/c0lc00553c · Cited by 66
Markey, A., Mohr, S., & Day, P. J. (2010) · Methods · doi:10.1016/j.ymeth.2010.01.030 · Cited by 65
High-throughput tracking of single yeast cells in a microfluidic imaging matrix
Falconnet, D., Niemistö, A., Taylor, R. J., Ricicova, M., Galitski, T., Shmulevich, I., & Hansen, C. L. (2010) · Lab on a Chip · doi:10.1039/c0lc00228c · Cited by 64
Optimization of immunomagnetic separation for cord blood-derived hematopoietic stem cells
Kekarainen, T., Mannelin, S., Laine, J. T., & Jaatinen, T. (2006) · BMC Cell Biology · doi:10.1186/1471-2121-7-30 · Cited by 63
Non-polydimethylsiloxane devices for oxygen-free flow lithography
Bong, K. W., Xu, J., Kim, J., Chapin, S. C., Strano, M. S., Gleason, K. K., & Doyle, P. S. (2012) · Nature Communications · doi:10.1038/ncomms1800 · Cited by 62
Biomolecular plasmonics for quantitative biology and nanomedicine
Lee, S. E., & Lee, L. P. (2010) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2010.06.012 · Cited by 62
Sickling of red blood cells through rapid oxygen exchange in microfluidic drops
Abbyad, P., Tharaux, P., Martin, J. L., Baroud, C. N., & Alexandrou, A. (2010) · Lab on a Chip · doi:10.1039/c004390g · Cited by 61
Nucleation and solidification in static arrays of monodisperse drops
Jon, F., Humphry, K. J., Irimia, D., Weitz, D. A., & Toner, M. (2009) · Lab on a Chip · doi:10.1039/b821785h · Cited by 61
Advances in microfluidics for drug discovery
Lombardi, D., & Dittrich, P. S. (2010) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2010.521149 · Cited by 57 · cited 1×
“Alternatively, identical samples can be exposed to distinct stimuli by varying droplet conditions for applications such as drug discovery [7, 8].”
BackgroundChemical Transfection of Cells in Picoliter Aqueous Droplets in Fluorocarbon Oil
Chen, F., Zhan, Y., Geng, T., Lian, H., Xu, P., & Lu, C. (2011) · Analytical Chemistry · doi:10.1021/ac2022794 · Cited by 57 · cited 1×
“to successfully transfect encapsulated cells [78].”
Pathak, M. (2011) · Journal of Membrane Science · doi:10.1016/j.memsci.2011.08.005 · Cited by 55
Monitoring a Reaction at Submillisecond Resolution in Picoliter Volumes
Huebner, A., Abell, C., Huck, W. T. S., Baroud, C. N., & Hollfelder, F. (2011) · Analytical Chemistry · doi:10.1021/ac103234a · Cited by 53
Identification of rare progenitor cells from human periosteal tissue using droplet microfluidics
Srisa‐Art, M., Bonzani, I. C., Williams, A., Stevens, M. M., deMello, A. J., & Edel, J. B. (2009) · The Analyst · doi:10.1039/b910472k · Cited by 51
Flow cytometry in clinical pathology
Virgo, P., & Gibbs, G. J. (2011) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2011.011128 · Cited by 48
A capacitive sensor for non-contact nanoliter droplet detection
Ernst, A., Streule, W., Schmitt, N., Zengerle, R., & Koltay, P. (2009) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2009.04.023 · Cited by 48 · cited 1×
“measure capacitance as droplets pass between the electrodes, since the droplet changes the overall dielectric constant across the channel, at time scales on the order of 10 ms [194, 195].”
BackgroundMicrofluidic Technologies for Synthetic Biology
Parisutham, V., Park, S., Kim, M., Park, J. M., Kim, T., & Lee, S. K. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12063576 · Cited by 41 · cited 1×
“Note that these thin membrane and core–shell methods highlight one critical role of droplet microfluidics in synthetic biology [105, 106] for both single cells and sub-cellular components.”
BackgroundRecent Advances in Flow Cytometric Cell Sorting
Osborne, G. W. (2011) · Methods in cell biology · doi:10.1016/b978-0-12-374912-3.00021-3 · Cited by 36
Generation of droplets with different concentrations using gradient-microfluidic droplet generator
Yeh, C.-H., Chen, Y., & Lin, Y.-C. (2011) · Microfluidics and Nanofluidics · doi:10.1007/s10404-011-0791-8 · Cited by 33
Lin, Y., Yang, C., Lu, K., Huang, K., & Zheng, Y. (2011) · Electrophoresis · doi:10.1002/elps.201100343 · Cited by 33
Cell encapsules with tunable transport and mechanical properties
Luo, D., Pullela, S. R., Márquez, M., & Cheng, Z. (2007) · Biomicrofluidics · doi:10.1063/1.2757156 · Cited by 32
Droplet Microfluidics for High-throughput Analysis of Cells and Particles
Zagnoni, M., & Cooper, J. M. (2011) · Methods in cell biology · doi:10.1016/b978-0-12-374912-3.00002-x · Cited by 30 · cited 1×
“One review [26] highlighted how the absence of dilution in”
BackgroundSynthesis of novel fluorous surfactants for microdroplet stabilisation in fluorous oil streams
Holt, D. J., Payne, R. J., & Abell, C. (2009) · Journal of Fluorine Chemistry · doi:10.1016/j.jfluchem.2009.12.010 · Cited by 29
Syme, C. D., Martino, C., Yusvana, R., Sirimuthu, N. M. S., & Cooper, J. M. (2011) · Analytical Chemistry · doi:10.1021/ac202705a · Cited by 24
Bourouina, N., Husson, J., Hivroz, C., & Henry, N. (2012) · Langmuir · doi:10.1021/la300398a · Cited by 23
A homogeneous assay for protein analysis in droplets by fluorescence polarization
Joensson, H. N., Zhang, C., Uhlén, M., & Svahn, H. A. (2012) · Electrophoresis · doi:10.1002/elps.201100350 · Cited by 22
Drug effects analysis on cells using a high throughput microfluidic chip
Gong, Z., Zhao, H., Zhang, T., Nie, F., Pathak, P., Cui, K., Wang, Z., Wong, S. T. C., & Que, L. (2010) · Biomedical Microdevices · doi:10.1007/s10544-010-9486-2 · Cited by 18 · cited 1×
“Alternatively, identical samples can be exposed to distinct stimuli by varying droplet conditions for applications such as drug discovery [7, 8].”
BackgroundApplication Properties of Stimuli-Responsive Polyglycerol Hydrogels
Salehpour, S., & Dubé, M. A. (2012) · Journal of Macromolecular Science Part A · doi:10.1080/10601325.2012.633434 · Cited by 12
Cited by
Emerging Droplet Microfluidics
Shang, L., Cheng, Y., & Zhao, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00848 · Cited by 1,584
Inertial Focusing in Microfluidics
Martel, J. M., & Toner, M. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-121813-120704 · Cited by 571
Collins, D. J., Neild, A., deMello, A., Liu, A.-Q., & Ai, Y. (2015) · Lab on a Chip · doi:10.1039/c5lc00614g · Cited by 528
Hydrogels and Their Role in Biosensing Applications
Herrmann, A., Haag, R., & Schedler, U. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100062 · Cited by 332
Digital Assays Part I: Partitioning Statistics and Digital PCR
Basu, A. S. (2017) · SLAS Technology · doi:10.1177/2472630317705680 · Cited by 300
Metadata
- Authors
- Lagus, T. P., & Edd, J. F.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 2013-02-22
- Volume
- 46
- Issue
- 11
- Pages
- 114005
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W2088212087
- Cited by
- 213
- References
- 184
- FWCI
- 10.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.